501 Seaspray Avenue .4 > 03 P/g I(j V/gl 0 U 45 30 LB FIBERGLASS ARCHITECTURAL SHINGLES OVER 15 LB FELT Cd 1/2" CDX PLYWOOD ROOF SHEATHING FASTEN w/ 8d COMMON WIRE NAILS @ 6" OC EDGE AND FIELD. DECREASE TO 4" OC WITHIN 4'-0" OF EDGE OF ROOF. 12 PRE—ENGINEERED WOOD ROOF TRUSSES @ 24" OC HURRICANE STRAP PER UPLIFT CONNECTOR SCHEDULE 1 4 6" EAVE METAL 5/8" DRYWALL CIELING �___ 2x6 SUB FASCIA R-30 INSULATION VINYL SOFFIT 0 THREADED—ROD TIE—DOWN SYSTEM (SEE STRUCTURAL DETAILS)-- S TU C C 0 0 PROTECTION OF OPENINGS USING WOOD STRUCTURAL PANELS 1/2" GYPSUM—BOARD (TYP.) •Min. thickness of plywood panels is 7/16 inch 1/2 WALL SHEATHING •Max panel span is 8 feet ___--_�(SEE STRUCTURAL DETAILS) •Panels must be precut to cover window Attachment hardware provided(fasten per table 1604.1.4) R-11 BATT INSULATION Label panel with location, ex. North wall-bathroom window TYPICAL ALL EXTERIOR WALLS Inspection required to verify above items have been complied with TABLE 1606.1.4 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS IZ FASTENING TYPE FASTENER SPACING(IN.) 1,2 THREADED—ROD TIE—DOWN SYSTEM 2x4 STUDS @ 16" O.C. PANEL SPAN<2' PANEL SPAN>21<41 PANEL SPAN>41<6 PANEL SPAN>6<81 (SEE STRUCTURAL DETAILS) (SEE STRUCTURAL DETAILS) 2 1/.#6 Wood Screw 3 16" 16" 12" 91, 2 1/2#8 Wood Screw 3 1691 16" 16" 12" Double-Headed Nails 4 12" 6" 4" 3" r..4 WOOD BASEBOARD Notes: 1.This table is based on a maximum wind speed of 130 mph(58 m/s)and mean roofheight of`33 feet(10 m) MONOLITHIC FOUNDATION, ON GRADE of less. w/WWM 6x6, OR "FIBER MESH ADDATIVE,' 2x4 P.T. SHOE w/ SEAL SILL 2.Fasteners shall be installed at opposing ends of the wood structural panel. 3.Where screws are attached to masonry/stucco,they shall be attached using vibration-resistant anchors OVER 6 MIL. VAPOR BARRIER BETWEEN SLAB AND SHOE ON COMPACTED, TERMITE TREATED FILL having a minimum withdrawal capacity of 490 lb(2180 kN). (SEE STRUCTURAL DETAILS) 4.Nails shall be I Od common or 12d double-headed nails. 1606.1.4 Protection of openings. In windbome debris regions,exterior glazing that receives positive .-V eet(18.3 m)in buildings shall be assumed to be openings unless such glazing is pressure in the lower 60 f Y\ impact resistant or protected with an impact resistant covering meeting the requirements of SSTD 12,ASTM E 1886 and ASTM E 1996,or Miami-Dade PA 201,202 and 203 referenced therein as follows: x:�/;\N 1. / m,x��, . . :. N .. 0 x x 1.Glazed openings located within 30 feet(9.1 m)of grade shall meet the requirements of the Large Missile N­ /N, , "' N N "S x /> Test. 1>y, 2.Glazed openings located more than 30 feet(9.1m)above grade shall meet the provisions of the Small Z "0�0/�O/�/, z Missile Test. XIISY,IS I �x N \6 Exceptions- Wood structural panels with a minimum thickness of 7/16 inch(11.1 mm)and maximum panel 77 77S span of 8 feet(2438 mm)shall be permitted for openings protection in one-and two-story buildings. Panels I n" x-, shall be precut to cover the glazed openings with attachment hardware provided. Attachments shaL1 be designed to resist the components and cladding loads determined in accordance with Table 1606.2B. Attachment in accordance with Table 1606.1.4 is permitted for buildings with mean roof height of 33 feet (10m)ir less where wind speeds do not exceed 130 mph(58 m/s). Drawings By: David Willis CAD Drafting 1031 N. 21st Street Tax Beach, FL 32250 (904) 249-4040 Job #: 212 TYPICAL SECTION Date: 4Z('AT 'P- 1/,d" V-011 06 /24/04 C� 0 P't 0 > Cc u 0 u > AREA OF ADDITION AREA OF ADDITION 0 I I I I I I I I I T I I I I Lim.I L , . . - , . I I I I I I I'I I I' I I L I I I.[I I I I I I I'.'.-I��.'.1 1 E�,�#.,, ,, .,.I,I,1 11 1 . . . . . ... . ... . . . . . . . . .. . . . . . . . . . . . - - I I � I � . I . I I I I I I I I I I I I L I I I I I I I I I . . . . . . . . . HHHHH., . . . . . . . . . . . . . . . . . . . . . . I I I I I T I I . . . . . . . . T r EMSTING X x FRONT PORCE 01 BEYOND T' 0: EXISTING +- - - - - - - - - - - - - - - - - - - - - - - - NEW LEFT ELEVATION- NEW FJGHT ELEVATION SCALE: 1/4" V-0" SCALE: 1/4" 1'-0" C, 0 U AREA OF ADDITION _j nN �z 2o6a 2e6a /4/ 2==ZZ2::f --------*14 le:1114 4 NEW FRONT ELEVATION SCALE: 1/8" 1'-0" 0 .0 AREA OF ADDITION AREA OF ADDITION 7� le u '�o 1---1--100�-- 0 I I I T I I I I I I I I I I 1 1, LAP LAP SIDING SIDING EXISTING/ "o Dmwings By: David Willis L �5O 2868 2868 2650 CAD Drafting 1031 N. 21st Street Jax Beach, FL 32250 (904) 249-4040 Job #: NEW REAR ELEVATION NEW FRONT ELEVATION 212 Date: SCALE: 1/4" F-O" SCALE: 1/4" V-0" 06/14/04 Sheet #: A 2 LEGEND PHONE V TELEPHONE OUTLET r Cd C.A.T.V. OUTLET 1_0 SINGLE POLE LIGHT SWITCH rT_ __1 11 1 SWITCH w/ DIMMER CN 3 WAY SWITCH FT_ __1 F -1 CEILING LIGHT 0 I IL:��J I U WALL SCONCE LIGHT G Vr 'A' + RECESSED CAN LIGHT SMOKE DETECTOR 0 S.D. WALL OUTLET GFI OUTLET > outlet in ceiling Gh 220 VOLT OUTLET P 220V S Q0 EXHAUST FAN Floor Plug 5 0 Located By Owner EXHAUST FAN W/ LIGHT 2' X 4' SURFACE MOUNTED S.D. FLUORESCENT LIGHT FIXTURE 71 SEE OWNER FOR ADDITIONAL ELECTRICAL DETAILS NOTE : outlet in ceiling P 1 PROVIDE AFCI 'S (ARCH-FAULT CIRCUIT INTERRUPTERS IN ALL DWELLING ZD� 0 UNIT BEDROOMS PER NEC ARTICLE 210-12) 2 . ALL SMOKE DETECTORS ARE TO BE NOTES ROOF TRUSSES : HARDWIRED AND INTERCONNECTED. L= ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY Al—I SEE TRUSS DETAILS FOR ALL INFORMATION ON TRUSSES PROVIDE ATTIC AREA IN GARAGE 0 90 TRUSSES AS SHOWN __j NEW ELECTRICAL PLAN NEW ROOF PLAN SCALE: 1/4" P-O" SCALE: 1/4" V-011 4-A 0 U 14'-0" 14 1-011 0 0 0 rr- 10" 7'-2" nJ _n oo, RAGE 200 U) LAUNDRY STO L __j U_ __j NEW FLOOR PLAN r-r __1 11 1 F -1 1 11 F -1 1 -o 00 'o L SCALE: 1/10" P-O" Ln L 't LL _j Ln 4m 0 Ln FU + 9902 >1 CN CN MONOLYTHIC SLAB (SEE STRUCTURAL DETAILS) 0 0) CY) 0 C14 Floor Plug 04 P" 4-a Located By Owner Work Shop :3 456 SF 0 U 0 J* FIN.FLOOR '4V ELEV. MIN.0'-8"ABOVE GRADE T r_1 (A 0 Ln 0 SEE STRUCTURAL DETAILS FOR: V) * CONCRETE SLAB INFO., * W/REINFORCING (OR FIBER MESH) INFO., * OVER VAPOR BARRIER INFO., Al— * ON TERMITE TREATED, CLEAN, COMPACTED FILL INFO., Dmwings By: David Willis 00 CAD Drafting NOTE : 1031 N. 21st Street Jax Beach, FL 32250 4'-5" 5'. 4'-5" 4. 5" 5'-2" 4'-5" (904) 249-4040 1 . A FOUNDATION SURVEY SHALL BE PREFORMED AND A J" 14'-0" COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE 14'-0" BUILDING INSPECTOR' S USE, OR ALL PROPERTY MARKERS Job #: SHALL BE EXPOSED AND A STRING STRECHED FROM MARKER 212 TO MARKER TO VERIFY REQUIRED SETBACKS. Date: NEW FOUNDATION PLAN 2 . THIS ST.RUCTURE HAS BEEN DESIGNED AS A PARTIALLY NEW FLOOR PLAN 06/14/04 SCALE: 1/4" F-011 OPENED STRUCTURE IN ACCORDANCE WITH THE FLORIDA SCALE: 1/4" F-0" Sheet #: BUILDING CODE SECTION 1606. A I J Cd INDEX OF D-R-A-WINGS : ARCHITECTURAL PAGES : 0 u C 1 TITLE PG (THIS PG) C1 SITE PLAN ( THIS PG) Al FOUNDATION PLAN Al EXISTING FLor, -.-� PLAN Al NEW FLOOR PLT.N M Al NEW ELECTRICAL PLAN Al NEW ROOF PLAN A2 ELEVATIONS rc� 9 C, D1 TYPICAL SECTION STRUCTURAL PAGES : (ATTACHED) 4-4 S1 S2 S3 kn S4 01 LOT 257 LOT 269 0 C-4 APPLICABLE CODES : FLORIDA BUILDING CODE - 2001 FLORIDA FIRE PREVENTION CODE - 2001 100 . 01 NATIONAL ELECTRICAL CODE - 1999 TYPE OF CONSTRUCTION : VI OCCUPANCY CLASS : GROUP R -3 RESIDENTIAL Ln BUILDING HEIGHT : NOT TO EXCEED 351 -011 L 0 0 NEW ADDITION 0 C; C� U-) SQUARE FOOTAGE INFORMATION < 3: 01 EXISTING HOUSE : Li 0 EXISTING HOUSE 11306 NEW : ROOM ADDITION 456 LO U) LOT 258 CONC. DRIVEWAY LOT 270 SPECKMAN RESIDENCE 501 SEASPRAY AVE. NEW TOTAL UNDER ROOF 11762 ATLANTIC BCH,FL 32233 100 . 01 FENCE NOT SH OWN SITE AREAS : DRIVE WAYS AND WALKS 242 TOTAL AREA OF COVERAGE 2rOO4 APPROV90 LOT SIZE 51000 CITY OF ATLANTIC BEACH SU160NO OfffeIGM N10V 00" 2904 SEA SPRAY AVENUE PRECENT OF COVERAGE 40% .0 (50 ' R/W) R E 1-7, E I V E-- D 0 C I i Y0 F A7 LA��T I HACH OCT 2 1 2004 144p SY: Drawings By: David Willis CAD Drafting ROOM ADDITION FOR. 1031 N. 21st Street Jax Beach, FL 32250 (904) 249-4040 The SPECKMAN FAMILY Job #: 212 SITE PLAN Date: 501 SEASPRAY "Em CORONA RD 06/14/04 SCALE: 1/10" F-O" ATLANTIC BEACH , FL Sheet #: C I 0