1510 Selva Marina Drive This plan approved subject to the following provisions being included
in the building;
In hollow masonry unit construction, each unit cell shall be
reinforced with at least one No. 5 bar at all corners; poured
and tamped with concrete; such reinforcing shall be properly
tied into the footing and spandrel beam. All wood truss rafters--
roof construction shall be securely fastened to the exterior
walls with approved hurricane anchors or clips. Footings shall
be continuous monolithic concrete' under exterior walls" reinforced
with two 5/8" deformed reinforcing* rods for one-
story buildings and three 5/8" deformed reinfor- APPROVED 1-
CITY.Of ATLANTIC BEACH
cing rods for two-story buildings. Reinforcing
rods shall be placed in the lower one�-third of the BUIL f D11 NC OF ICE
the footings, properly placed and fastened on ate.__
metal saddles with wire. Footings shall be 20"
wide and 8" thick minimum.