Permit Bldg Res Alteration 511 Ocean Blvd 2010 CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
... INSPECTION PHONE LINE 247-5826
may1x31
Application Number . . . . . 10-00001202 Date 10/04/10
Property Address . . . . . . 511 OCEAN BLVD
Application type description RESIDENTIAL ALTERATION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 1900
---------------------------------------------------------
Application desc
INSTALL BEAM
-----------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
GRISWOLD, S .J. OWNER
511 OCEAN BLVD.
ATLANTIC BEACH FL 32233
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 60 . 00 Plan Check Fee 30 . 00
Issue Date . . . . Valuation . . . . 1900
Expiration Date . . 4/02/11
----------------------------------------------------------------------------
Special Notes and Comments
*2007 FLORIDA BUILDING CODE W/2009 REVISIONS
NATIONALELECTRIC CODE
*REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING
DEPARTMENT IMMEDIATELY.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE DCA SURCHARGE 2 . 00
STATE DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 60 . 00 60 . 00 . 00 . 00
Plan Check Total 30 . 00 30 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 94 . 00 94 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Road, Atlantic Beach, FL 32233 D
Office (904)247-5826 Fax(904)247-5845
SEP 3.UZUIU
Job Address: _5_// OCEp N B L.V.h, Permit Numbe .
Legal Description t—o-r I 0 B L K 13 Parcel# By
Floor Area of Sq.Ft. q. t
Valuation of Work$ 1 ,960 Proposed Work heated/cooled $V,4 non-heated/cooled AIA,
Class of Work(circle one): New Addition <Iieration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s)(circle one):. Commercial esidentia
If an existing structure,is a fire sprinkler system installed?(Circle one): o N/A
Florida Product Approval# N A
For multiple products use product approve orm
Describe in detail the type of work to be performed: /• R NI o VF C o L o M N AA-16
OVrR #d-)91> rot SvppoRT. Z. /chow' 0iv-5 W,IV b10%A.) /9A.1b FiZL ht-L-C •Vi7W r1v6977nNG
NA ini txT /?V b 6-,yo `urv► B,�AaO //✓72F2/ooz ,
Property Owner Information:
Name: SC v T-r 6 4 I S W u L A Address: 5- °C- f C/
City A fC.A� 77C ,Qty+cK Statert-Zip LI-3 Phone 9 V Y
E-Mail or Fax#(Optional) Z Lf 6 7 5 4 4 t3 G o M CA s-r. N F T
Contractor Information:
Company Name: Qualifying Agen
Address: City __State Zip
Office Phone Job Site/Contact Number Fax#
State Certification/Registration#
Architect Name&Phone#
Engineer's Name&Phone#
Fee Simple Title Holder Name and Address
Bonding Company Name and Address
Mortgage Lender Name and Address
Application is hereby made to obtain a permit to do the work and installations as indicated I cert that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null
and void tf work es not commenced within six(6)months, or if construction or work is suspended or abandoned for a_period of such)months at airy time after
work is commenced. I understand that separate permits must be secured for Electric Work,Plutnbing,Signs, Wells,Pools, urnaces,Boilers,Heaters,
Tanks and Alr CondlNoners,eta
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y&k NOTICE OF
COMMENCEMENT.
I hereb certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this
type olYwork will be complied with whether specified herein or not. The granting of a permit does not presume to Vve authority to violate or cancel the
provisions of any other federal,state, or local law regulating construction or the performance of construction. "° w
Signature of Owner Signature of Contractor kT ES 0 on- 1- WWI I
i
Print Name S C.oT'T G R is w o c_b Print Name
........I................ , " :...,...
Swo t subs before me s e ore me
thi ay f 20 ` ` R C "
L PAIV1100teli#BB 95"68
ry ��GRAHAM- IF,'-0 CITY OF ATLANTIC BEACH
Not lic '" r EXPIRES:February 14,2014 otary PqWuIREMENTS AND CONDITIONS.
Bonded Thru Notary Public UnderwrOre
....w,.r.+ Revised 01. 6.10
MVIEWM BY: DATE: f�
f�ti tlr
CITY OF ATLANTIC BEACH
OWNER / BUILDER AFFIDAVIT
^•cif �r
I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION
CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW:
DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES:
STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED
CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT
LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS
YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST
SUPERVISE THE CONSTRUCTION YOURSELF YOU MAY BUILD OR IMPROVE A ONE-OR
TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR
IMPROVE A COMMERCIAL BUILDING AT A COST OF $25,000.00 OR LESS. THE BUILDING
MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE.
IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR
AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT
IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT
HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST
BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS
YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE
LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING
ORDINANCES.
II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,
THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE
PURCHASED.
III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO
OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY
EMPLOY ON THEIR IMPROVEMENT TRADES.
IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY
CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO.
455-228(1). AN"OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY
SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS
CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE
BUILDING DEPARTMENT(247-5826) IF IN DOUBT.
V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE
STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN
OWNER-BUILDER PERMIT.
5I) 6)66-;2Vt! &L vb 2Y6 7S6Y
ADDRESS / PHONE NUMBER
SCn i� &(21S Iyot-LO
PRINT NAME
SIGNATURE DATE
Before me this-30 day of SCP 01,19M ,20/v in the county of
Duval,State of Florida,has personally appeared herin by himself/herself and affirms that
all statements and declarations are true and accurate.
Notary Public at Large,State of. County of 2;�,jr,
P onally Known
roduced Iden£rficati
SHI L RA
Notary Sign '* SI N#D 957760
ded Thru N ry Public Underwri rs •—__....__
F:BLDG/Owner-B -
MASONRY
CHIMNEY
WINDOW
WINDOW
TO BE
REMOVED
SEE SHEET A2
O FAMILY ROOM
0
z_ PARTIAL PLAN
'S
POST
TO BE
REMOVED
SEE SHEET Al
Mr. & Mrs. Scott Griswold
511 Ocean Blvd.
NORTH Atlantic Beach, FL 32233
SCALE 1/2" = 1'-0" 9/30/2010
Proposed Building Alterations
i
GEit �luC'
c FI LIYVG
eel LI"
' 7 3/ 3Z" R.47TED
5 H r,Au4: 8oAA $AT T i NSULAr,om
K RAFT (?A
r
/ 80A
Nc-L Cs
3
i
LL-
FL
fFA r`AIS T,4z4 5-- Z x '� y7-v"3r �« SWCAT4ixj6, ATTACH wr, H
5N/riGtfS MR S r?r sl _x .. Sd i�t#JC- SHA&jw r.A4,V,
e97-7-Ac-H" wrrH NAILS S PAC C-D 4 "
�2d Cam'" ou IVAIt,S on/ (PEAIMC'rt"R At->o i "i-EVtOR )
M R 16 " O, C
l er V) 4 Cf-,.-, R E
N VREMPvAL V t vv th `rCR ---CAC t--D
Vh L w rr 4 Two 3 d GALV, hJ ku-
P�OK x'14r,v Gt.0
Mr. & Mrs. Scott Griswold
511 Ocean Blvd.
Atlantic Beach, FL 32233
9/Sol 2or o
SHEET A2
gligill'i Copp 90..
a xetit
r —
4-2
JI I .--q,
=x i>T
hT
'M7oW _x:tii 'J •�nTc l+ / I w,"- yy� �_'Li
i"ALIA
I
a
a`..Z r -o PAS II-
{ I icy
1-Z_
-
II i
1
!• WR(
vnhJv � V�
ti
W4xly
4-4
I DESIGN UITERIA:
4i
ALL DESIGN IS IN ACCORMNCE WITH TNB SSAR6tR0 BUILDING CODE.
DESIGN IAADS:
--1 LIVE P11DP - PIAS YO PST
_ MIND BASIC .- l00 MW - TO PSF
WIZ -�I "YJI
L2x2N�FIn 6T.yix
A.1` 301 - TE -DESIGN PER ACI IlS (BJ) 6 GONSTRUCTIW AS PER ALL 3U1 (LATEST EDITION)
PM /L ._�/ Wiz B. ASM 615ING STEEL: XIGN YILLO BSRENGTN STEEL CONPOWIEG N —
` I! ASM D W NEAFE 60. —
O- WELDED WINE STEEL
A9 PER ASM-IES-)J.
•��� D. 9IWCNWL STEEL DESPDO IE BE -36 GRAM. WITH AISE ALL ORKSL: ALL
fA'�EAP 10 ;' 1 1 CryPLLY WITLRSTHE AISC SPECIRG MS MR SNE DESIGN, FABRICATION
H17E GF P+-�C.
AND PRBCSIWI OF SS8IICNRAL STCEL. Ill
l� E. NICK STRENGTH BOLTS - ASM A-324
I (<� d F. WELDING O.ECfRODFs SHALL BE E)01(1(
G. ALL EYED M STEEL SHALL MYN ONE SHOP COAT OF RED OXIDE PAINT/
RW LEAD PAINT AS APPROVED BY SNE ENGINEER. A qw W Om:Rsn)
N. STEEL JOIST: STEN.JOIST INSTITUTE - 1986.
MEI/-� KFIrs:n
To "Akl! 'ST GERRAL NOW:
1. V r DOVER TO RINFORC6IV.NY EBALL BE AS FOLLOWS (UNG):
E - ALL SOK)AND BOTMI •,
3
Sw IAB (A(X,BOVE MOM)S 3/4" !MO►OMMD DAM C TMIRW ON,
2. ALL RMFOECENENT SRALL BE REE AND SECIIRN IN POSITION BY AND IMUIMD�DIlfCLLT10Mf
OF PLACEBO Of
REINFORCING
STEEL E SH OT1 UT BE ISE NOTED, DETAILING AND
MAXUM.OFFSTAANDABD PRAMICE POR MAILING IS ARET DCCOUAKE WEOONGRESE _ 715 ATLANTIC BUIL
STIUUNRES. (A I-315). 1 REAL F Mi
R NAIL. A
q 3. SPLICES IN BRIMMING. LEEPERHUATED, SBE 63 FOLLOWS:
ATLANT
WELDED WINE FABRIC- - - - 6" - pIBiN
ALL OTHER_ _ _30 EAR. DIA.
3-NN.V M%
`. YYS+F.•:-. -- '.� y w r Bi♦A r 340Yw wr ,.z�t
_ _ r
i
i
CONS TRUC TIO UfaA WIN
i
FOR
AMOCO TSI TION #
715 ATLANTIC BLVD.
ATLANTIC BEACH , FL.
• uyI UA-KAYAL
AUR TA
xa321P ire.
ATLANTIC
BEACH
� pIA I BVIX Ntc
32233
...5 . NEPTUNE oar ,�,
BEACH
2 1994
LOCATION MAP
SHEET TITLE_------__ -- I`iandam
1 of 3 TITLE SHEET
2 of 3 REMEDIAL SYSTEM LAYOUT
3 of 3 REMEDIAL SYSTEM DETAILS a 'ix
I.
I I I,I I I
I.'
.11T
TI 11 11 1 11
II 1
IT
ItIl I I T
III T-I I I III I I ICT
I I I I I I TI
TII �ILL lm I I I
11" T,
IIIT 1 1, '1 IT' TI 1-1 IT.
I I T
�IlIll-TI T III I I I I`C
"I I I I 'I
E T I I
Wm.
�u
177= WT
0l Ir Nth
Mla.
AIW
REVISION—— DATE
®Index
REMEDLAL SYSTEM LAYOUT
AMOCO"M
ENG 7 15 .1"N T IC BLVD
TLAN I IC
0 EAC,I. FL
'i, i LL. I LIIT 36 TOWNSH.p 'S. FANTL 29E
FL::': F,' 4[[L SCALE AS SHOWN JOB NO. 104240
DRAWN B, -D.W.B -- DISK NO -
CHECKED Bf - L.W.G. DWG. NAME 669SITE
DATE - 10-19-94 DWG. NO, - 2 of 3
I.
Lloyd lfC"f 'it, 11 E,
AREA CALCULATION:
ALTERED,ENCLOSED:4 S.F.
CODE SUMMARY:
1.DESIGNED PER FLORIDA BUILDING CODE,
RESIDENTIAL,2007 WITH 2009 SUPPLEMENT
2,RESIDENTIAL OCCUPANCY:R3
3.TYPE V-B CONSTRUCTION,UNPROTECTED
4.BASIC WIND SPEED:120 MPH,ENCLOSED ONE-STORY,
ROOF HEIGHT-NA(EXIST),SLOPE-NA(EXIST.)
5.WIND IMPORTANCE FACTOR:1
6.WIND EXPOSURE CATEGORY:EXPOSURE B
7.INTERNAL PRESSURE COEFFECIENT:ASCE 0.181
PARTIAL FL00
1/2"=V-0'
Ca "�[eaSQ � �����'
Ick' Igo „
oc`c
1 � /m
.�ha/I �s
ELE
1/2"=11-0.
neoear aeme
KITCHEN MAIN CLG.LEVEL I FURRED CEILING (MAIN CLG.LEVEL 4*"NrMfT
2742 HERSCHEL STREET
- - _ - - _ _ JACKSONVILLE,FLORIDA 32205
904.389.5456 X12
FLORIDA LICENSE:AR0008958
AFTER INSTALLATION OF
BEAM,REMOVE COLUMN
WALL IS FURRED OUT THIS SIDE A 2 STUDS NOT EXIST.,
ADD 2X4 SYPP##2 STUD
EXIST.2X4 STUD WALL
ADD NEW (2)2X8 X 6-01
SYP#2 CANTILEVERED BEAM
(SEE ELEVATIONS FOR FAMILY RO
LOCATION&DETAILS)
1/2"0 THREADED ROD Q
MAIN CLG.LEVEL
tz
t
LAUNDRY ROOM Z o
2X8 SYP#2 X►oWOE
Q
tL =
ATTACHED TO EXIST. I A O Q
' INSTALL NEW(2)2X8 X 6'-0"L SYP#2 (4)
GABLE 6d NAIDLSTEA SUDSTy/ W ~ u A
\
PLAN CANTILEVERED BEAM ON TOP OF A
EXIST.CEILING JOISTS ORIGINAL GABLE Q
NUT END WALL
PLATE WASHER
EXIST.CEILING JOISTS
(2)SIMPSON LTS12
EXIST.DBL.TOP PLATE
TWIST STRAPS FROM
BEAM TO 2X8 A O w
w WA cq
� U00a A
SIMF c,ON H2.5 OR I IIII WW
CON 4 ECTOR(TYP. a
LOC IONS) IIII MAIN CLG.LEVEL
FURRED CEILING
REVISIONS:
IIII NO: ITEM: DATE:
1/2" HREEADED R@ 1.CHANGE SUPPORT 10-14.10
IIII
I IIII
IF 2 OS DO NO ST., ( III DRAWN BY: DATE:
ADD 4 SYP#2 S IIII AFTER INSTALLATION OF RBP 9.14.10
IIII BEAM,REMOVE COLUMN APPROVED BY:
IIII PROJECT NUMBER:
III D
IIII PROJECT NAME:
IIII ALTERATION TO RESIDENCE FOR
LAUP I RY WALL ( IIII MR. & MRS.
IIII SCOTT GRISWOLD
IIII 511 OCEAN BLVD.
III ( ATLANTIC BEACH,FLORIDA
IIII SHEET TITLE:
H
PLAN 8 ELEVATION
I w T'O EXIST.FLOOR JOISTS
NUT&2"X 2"X 1/✓3"PLATE SHEET NUMBER:
WASHER EXIST.GIRDER Al