Loading...
Permit 330 Dudley Road CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH FL 32233 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 4/29/03 Parcel Number . . . . . - - Property Address . . . 330 DUDLEY ST ATLANTIC BEACH FL 32233 Subdivision Name . . . Legal Description . . . Property Zoning . . . . RESIDENTIAL GEN 2 FAMILY Owner . . . . . . . . . BEACHES HABITAT Contractor . . . . . . BEACHES HABITAT Application number 02-30023251 000 000 Description of Work SINGLE FAMILY RESIDENCE Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . �--- Bul ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL Book 10187 Page 2488 Thi erg w pr by lnc200 1118 Pa P.O. Box 50939 a : 1e: 2441 88 Jacksonville Beach, Florida 32240 Filed & Recorded 10/15/2001 12:32:51 pM JIM FULLER CLERK CIRCUIT COURT NOTICE OF.COMMENCEMENIPUAL COUNTY TRUST FUND $ 1.00 RECORDING t 5.00 STATE OF FLORIDA Permit No.: COUNTY OF DUVAL Tax Folio No.: The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance with section 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property:(legal descri tion of property and street address if availab .) 2. General description of improvements: To build a single family residence 3. Owner Information: a. Name and Address: Habitat For Humanity Of The Jacksonville Beaches,Inc. P.O. Box 50939, Jacksonville Beach,FL 32240 b. Owner's interest in the site of the improvements: 100% C. Name and Address of fee simple title holder(if other than owner) : N/A 4. Contractor: a. Name and Address: b. Phone Number: C. Fax Number:(optional, if service by fax is acceptable) 5. Surety on any payment bond: NONE 6. -Name of any lender making a loan for the construction of the improvements: N/A 7. Persons within the State of Florida designated by owner upon whom notices may be served as provided by Section 713.13(1) (a)7,Florida Statutes: (2- &c> 1-2- 1<� L,--, ALT' ,P.O. Box 50939,Jacksonville Beach,FL 32240 Phone: (904)241-1222 Facsimile: (904)241-4310 8. In addition to himself, owner designates the following person to receive a copy of the lienor's notice as provided in Section 713.13 (1) (b),Florida Statute(Name,Bank and Address): N/A 9. Expiration date of notice of commencement: 1 year from the date of recording. Theforegoi�}ginstrument was acknowledged before HABITAT FOR HUMANITY OF THE me this L '`day of 5CA)b ,!2001,by �ra r� JACK SO I LE BEAZ2juJ44 S. 16ui &v+,who [ ] is personally known to me or t( as produced � DL. as identification By: (``' / 10B ADDRFM�J2 -,:-3C TYPE WORE PROPERTY O Q CLb T ELEMONE CONTRA R C r TFa_FTHONE t PERMIT NUMBER '- I DATE Z INSPECITONS.• FOon7VG SLAB 70/-z S ��- TTE BEAM LEVTEL NAII.IIV G � FRAMIIVGICOYER UP INSULATION FINAL BUILDING C EVMC4TE OF OC ANCY L " .G u ELEG3 IC4L PER11B'3#_ (g — 3.a,eS l EVSPECHONS ROUGH I03 MECWCWC4L PERMIT# INSPEMONS ROUGE I FINAL M-UAMWGPERMIT# •a�a I INSPECTIONS ROUGE/UNDER MAB I o f i OlOz- TOPODT WATER/SEWER Fi SAL. J NOTES. FLOODPLAIN DEVELOPMENT INFORMATION Location:: Type of Development: ► �y Flood Zone: Required Lowest Floor Elevation:— If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed de to m Date /'/ r? % rApplicant's Signature Department Use: i Required Lowest Floor Elevation As Built Lowest Floor Elevation Survey Filed with Building Department Building Department Repres ntative s MAP SHOWING SURVEY OF: LOT 2, BLOCK 2, LEWIS SUBDIVISION AS RECORDED IN PLAT BOOK 24, PAGE 92 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA DUDLEY STREET (FORMERLY EDNA STREET) 50' RIGHT-OF-WAY o (S89'58'28"E 49.98' FIELD) e FOUND IRON EAST 5 00 PIPE (LB 048) " ' PIPE (NDO CAP) . r" ' 250.00BY PLAT a � 3 ui N N N WOOD POWER POLE W CONCRETE DRIME L1 ry a rVl Q 7.8' /1 15.2' o C V J 0 t0w ^ Vf 0 0 r7 O W C) U -co Q � � p � oWo C� 00 LLJ J I LOT 3, BLOCK 2 N Z = W N c LOT 1, BLOCK 2 o {� VF- (:) o a d 0 z LA► (A Z W '` 0 � 17.V 7.8's <V 0.7' 6' CHAIN UNK FENCE WITH 8AROEI) ?ARE 6' FOUND IRON WEST 50.00 PIPE" (,D ILLEGIBLE) PIPE (NOO CAP) (S89'53'19"W 50.13' FIELD) UNPLATTED PART OF SECTION 17 NOTES. 1. THIS IS A BOUNDARY SURVEY. 2. BEARINGS BASED ON WESTERLY LINE OF LOT 2 BEING NORTH. 3. NO BUILDING RESTRICTION LINES PER PLAT. 4, BENCH MARK USED IS NAIL & DISK (LB 3672) 30'f THIS SURVEY WAS MADE FOR THE BENEFIT OF zria.► CSF SOUTHEAST CORNER OF LOT 9, BLOCK 1, 2398 MAP SHOWING SURVEY OF: LOT 2, BLOCK 2, LENS SUBDIVISION AS RECORDED IN PLAT BOOK 24, PAGE 92 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA DUDLEY STREET (FORMERLY EDNA STREET) 50' RIGHT-OF-WAY p a (S89'58'28"E 49.98' FIELD) e PIPEFOU ( 1/2- IRON EAST 5 .00, PIGPEN(L8 1048) " ' PIPE (NO CAP) '- taJ a 250.00' BY PLAT N N W000 POWER POLE LiJ CONCRETE DRIVE LJ L.y ANCHOR CONCRETE WAUc O 7.8' ' Q C 17.0' a Z 0 TO.O' Q N pM w d oco co O a? W LOT 3, BLOCK 2 N Z = > N LOT 1, BLOCK 2 S ri S Z f W L W cn Z f 0) o " tom 2Z = a 0u, wn 0 0 z Wvt wvi zw oo� 17.1' 7.8'g �i .X x - 0.7' 6' CMAIN Uw FENCE WITN SARKD "RE .6' FOUND IRON WEST 50.00 PIPEND 1/2- IRON (ID ILLEGEI E) PIPE (NOO CAP) (S89'53'19"W 50.13' FIELD) UNPLATTED PART OF SECTION 17 NOTES: 1. THIS IS A BOUNDARY SURVEY. 2. BEARINGS BASED ON WESTERLY UNE OF LOT 2 BEING NORTH. 3. NO BUILDING RESTRICTION LINES PER PLAT. 4. BENCH MARK USED IS NAIL & DISK (LB 3672) 30't THIS SURVEY WAS MADE FOR THE BENEFIT OF SOUTH OF SOUTHEAST CORNER OF LOT 9. BLOCK_11_ 2398 TA.,rP%• f" , ...—-. - --- . ..... ...._.. MAP SHOWING SURVEY OF: LOT 2, BLOCK 2, LEWIS SUBDIVISION AS RECORDED IN PLAT BOOK 24, PAGE 92 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA DUDLEY STREET (FORMERLY EDNA STREET) 50' RIGHT-OF-WAY o N (S89'58'28"E 49.98' FIELD) a FOUND IRON EAST 5 .00' PPE"(LB 1048) " j PIPE (NOO CAP) r a 250.00'Y BY PLAT W vi 1 N N.. 1 1Nppp POWER POILE L ' CONCRETE WC W CONCRETE ET AL9 Ln 7.8- 15.2' O C h 17. 0' Z 1Q0.0w Q N QM d w J I o ti QW � oo OIR Ld r LOT 3, BLOCK 2 r— N ZM= W N am) LOT1. BLOCK 2 F-- w F_ OZ Q D: v U Lo Q V) w0 O Q 0 z w to o Zw Oa: 25.1' 7.84 G2 _xx _ 0.7 5' CHAIN UNK FENCE W1114(BARBED "RE 6' FOUND WEST 50.0 0' pPEN(ID ILLEGIBLE) PIPE (NOO CAP) (S89-53'19"W 50.13' FIELD) UNPLATTED PART OF SECTION 17 NOTES: 1. THIS IS A BOUNDARY SURVEY. 2. BEARINGS BASED ON WESTERLY LINE OF LOT 2 BEING NORTH. 3. NO BUILDING RESTRICTION LINES PER PLAT. 4. BENCH MARK USED IS NAIL & DISK (LB 3672) 30'i THIS SURVEY WAS MADE FOR THE BENEFIT OF SOUTH OF SOUTHEAST CORNER OF LOT 9. BLOCK 1, 2398 TAhAC'DA C o^0IAICnhl. LIAMITAT rnn /tai A►u'rli m J� CITY OF ATLANTIC BEACH }, s� 800 SEN 41NOLE ROAD / +� ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 j Application Number . . . . . 02-30023251 Date 4/29/03 Property Address . . . . . . 330 DUDLEY ST Application description . . . SINGLE FAMILY RESIDENCE Property Zoning . . . . . . . RESIDENTIAL GEN 2 FAMILY Application valuation . . . . 64342 Owner Contractor ------------------------ ------------------------ BEACHES HABITAT BEACHES HABITAT ---------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . 150AMPS, 1PH, 3W, 240V,NEW SVC Permit Fee . . . . 85 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 85 . 00 85 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 85 . 00 85 . 00 . 00 . 00 44 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL FROM GRANGER)C PHONE NO. : 9047640038 Apr. 30 2003 10:49RM P1 04/29/2003 iEACHES HABIT47 PAGE 01. MY OF ATLANTIC BEACH,]PLORMA APPLICATION FOR ELECTRICAL PERKU 't TO ITM Crate MECTRICAL VS?f4Toa: DATE �� 20 d� IZ�ORT.AN7'NOT'ICE; IN CMSTMATION C*PPMIT OPAN FOR 0=0 THS"WCRk As DEsct M IN Me lt3L1 oW24G,Va FILit my AoRU To A'ERMM SAID WORK IN ACWTtDA=WITH niE A,TTACIMR" PKIRCATIONS,9JMCH ARS A PART RMCF, ANDIN ACCOR33ANCE WITH THE ELBCTRiCAL 00MAT MM CAD AND YO COCA WCBS. ELECTIUCAL F MM: SIONATM. ca r nWls N.gM : AF91 (z— BLDG.SM --[/ z—B2.DG.3?ZEE--[/ BETWEEN:,-,�' _ rE <:�A RES.( APS',( ) CQKK( ) PUBLIC( ) L-wvs.( ) NEW( y OLD( ) REW.( ADDMON( ) T1tAff..PW ) TEMP.( ) SIGNS( ) SQ.FT. $ERV='. IOW 'INC3iEAM' FAIU ONT3 C'TOR Sf A.r'4IPS: COPD -"-,A;.- I- FEES S'w-lTcmokBl�.HAxER l� AAgS [ I PFI W OLTRACEWAY Exiv, SERV,S1 AMPS �T-'P=SiW VOLT 14CEWAV FEEDBMS NO, SIZE NO. SIB NO. SIZE 1 ,LIGHT LNG O UTLE i 8 CONCEALED OPEN TOTAL RMPTACLES CONCEALED i OPEN t TOTAL a.aokvm 1 3 L100 AMM swiTcas ZNCANDESCEN'I' FLotymc,ENT de . gI a 1 oo.aaass, ova A??LL.NCEa I ML MAIM. AIIt i�.p,RA�I3�G ILP.A MNG G"£I . K1V FEAT C0O'DTT"OVI NG COMP,MG'COR QTMR MOTORS AMPS ICTAI,T i 0.1 OYER MoTops H.P. YOLTAC3E pHs NO. 1Ii.P_ VOLTAGE PHS t M1SCE LANEflUS tlNI9ER booI OVER 600V ntANS.FO&MIRS: ' NO. KVA NO. KVA, No.NEO".�1 TItANSF. No VA MA MOTOTii SI.T S�WITCE1 FLASHEI+S EACH SIGN �- - CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247 +` t PERifi{IT fiflRIATEON< LCJCATION II11FOtM ►T#O Permit Number: 23251 Address: 330 DUDLEY STREET i Permit Type: BUILDING ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: 24 Proposed Use: SINGLE FAMILY Lot(s):2 Block: 2 Section: Square Feet: Subdivision: LEWIS SUBDIVISION Est. Value: Parcel Number: Improv. Cost: 64,342.00 -- —� OWI4tER.INFORMATION Date Issued: 1/03/2002 Name: BEACHES HABITAT j Total Fees: 3,627.14 Address: P. O. BOX 50939 Amount Paid: 3,627.14 JACKSONVILLE BEACH, FL 32240 Date Paid: 1/03/2002 P 04)241-1222 C _Work Des/ca: CONSTRUCT NM .44 T S 4 —— — — _ _ -CONTRACT' BEACHES HABITAT E 0.00 E 280.00 1,250.00 qty 5.0 52 Q ` 7 5.77 x CAMS% 0.30 W AL _P12M 325.00 O 35.00 k� "# � 5.46 WK 1+200.00 1 I 5"°'�" -+x:tom, ,h 3 #2.1N� , 4:fiu iy;a•`=:. i _A TREE ARRIG n ;:� J, h i COVER UP - � ��� x� up DING CERTIF/OCCUl�Y ' F x � NOTICE- SPECTI44 � tliStAT LAST Z4 HOURS tOR T+D 1 PECTION BUILDING MATERIAL, fi;`�4 R(S FF�CT�tIiWOI#S h�lUST NO _ PUBLIC SPACE,AND MUST BE CLEARED UP A g HAULfb ` N' ATO O� . "FAILURE TO COMPLY - ULT IN THE ` PROPERTY OWNER PAYIN �3 t P .' * S" ISSUED ACCORDING TO APPROVED PLANS'4yh & S PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW, ' CWUlypt: OC k wc: 1 ATLANTIC BEACH UILDING DEPT. ANN 8�1 ��Q 133011,11 'N l M C® 6355 !3647.14 f"Ift MO: 9M/12 Tian: 13:26:47 UT )UUUU2 City of Atlantic Beach 2/21/03 Change Service Order Comment Maintenance 10: 59: 33 Ser;ice`Order Type . . MS METER SET Svc order nbr 87277 Status : COMPLETED Issue date/time: 9/06/02 14 : 03: 35 Location ID 18130 330 DUDLEY ST City . . . . ATLANTIC BEACH Meter number . Service cd/Seq WA 000 WATER To complete service order type information, press Enter. 4=Delete 5=Display Prt Cmt Cd Numeric Value Loc Opt (F4) Alphanumeric Value 4 Decimals (F4) _ CM PAID FOR 3/4" METER ON PERMIT 23251 . PAID 4 CM ALL WATER AND SEWER CONNECTION CHRGS . 4 4 4 4 4 4 F3=Exit F4=Prompt F12=Cancel F18=Enter readings CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J v ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00025374 Date 1/13/03 Property Address . . . . . . 330 DUDLEY ST Tenant nbr, name . . . . . . INSTALL HVAC & DUCT Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . RESIDENTIAL GEN 2 FAMILY Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ BEACHES HABITAT OCEAN STATE HEAT & AIR 1476 ATLANTIC BLVD. NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----- ------------ ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 s BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WIH:U PART OF THIS PE i T SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL BUILDING AND ZONING INSPEl.-.TICN DIVISION CSTY OF ATLANTIC BEACH-! ATLANTIC 31AGH.MORIDA 32"S APPLICATION FOR MECHANICAL. PERMIT CALL-,N NUMBER (MPC 2TAN T—A�coiicsnT`c ccmpieTe ail Tare; in sec`icns i !I, !II, anc r ��.C�i iC.y ,Slr.er Addrr u:--/3 .J �J �'-�� •'� CFf Intersecting Sireut: 3etwaee tC/'7°!/l IZCI'1t And Z1 L>n L r y ! 3 ^(4G I Suh•d(rition il. ?CENTIRCATICN —-o be completed 'cy nit applicants. I' in comidaretion of permit giren ?or doinq the wort is ducribed in the above ttal--t�.nveay agree to perform mid work in eeeorCenes It the attoeitpd plant ane toecificationt witieb are a ?art 'vreoi end in accordance with the G!y of;acitonriilo orainaneas end Standards of good.praetice iitted therein. Name a4 Mecnanicsi I -••_ _ Cantractors Cnj eeaatar jPr(nt� �C' v / Master Herne ai _ Sigaanre of Orn ar A Agen/ Arehilect ar -ngineer I1. CeNBUL INFO a N Type of healing fei: v IS OTHER OONSTRUCrON SEIN OONf,0 'C THIS 3UILJING OR SITE? C: yes— U C Nantrsi Q• Contra(Wilily C Cx IF PERMST GIVE 4UMBERR YXTRF)11 Q C•Mer—Specify �d �l IV. )A CNANICAL 3OUIPfAMT TO 11 INSTAUFD NATURE OF WORK Ip 9.40 canpiete fid e(comoot mm as beck of this me is feI !7 Resicientlat or L.. Cammerotal �Ftsat ❑ Speu = Reesel" me/Canhsi a Aoer rZ 1Vew ewidlnp /,Vr CanddteRfeg: a ReerR �CeMee{ Existing Building . �f 3trct Syelem: Mefariti �(ck•••a i� Reolacement of existing system Me■iewnulsrch ��� e(re Ei New Installation(No system preriouaiylnstaliad► G C Extansion or add-on to existing syetom C. other—3oaadty C Coel(eg fewer. Gp&6h g o+R (,.^ prw speinklare: Nentber r 4eed` C He►ete. ❑ ►AeRJ(ff C 6r lefer ;/Nslrtter► THIS SPAC1 FOR OFF=AJM ONLY Q.Wadies perR" ------ rber) (R'e�+seA) C. Tara je.Rrb.r) Rantarks Q UQ wade— (—tear) Q Wa(ttNti prewwe wool Penni► APpr'eeed Sy Der1 Q Were, 'LerPamtif R.. Otis..—iveeity LIST ALL SQUIPMENT AM CONDMOMMG AND REFRIGERATION 3:QU211MIT Caaeesty A Mmmbse Units D-wiption Yodel Number mAnutaettuse (1`ons) >1ei . n/" J lv MAT=-FURNACES. 3011ER& FMY2LI= CaywrlLY wOpseebs Ttmmber Vnita lleesriPtlos Yodel Nbmber Yaaulaacam (2m) Aiwey f. 1T-w 6 r , oc) It- TANKS now XmT :famteai CapsmCl 170s L4+>id Iitttaaa of Seckel Ap�rarr{nt sed Dlmeaadaas Contained leammxaotww Na Aw—r CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 yJ;31�A Application Number . . . . . 02-00025018 Date 10/18/02 Property Address . . . . 330 DUDLEY ST Application description . . ELECTRIC ONLY Property Zoning . . . . . . . RESIDENTIAL GEN 2 FAMILY Application valuation . . . . 0 - Owner Contractor -------------------- ---- ------------------------ BEACHES HABITAT CMA ELECTRICAL CONTRACTORS 8814 DARLINGTON DRIVE ATLANTIC BEACH FL 32233 MYPT FL 32228 (904) 765-6262 ---------------------------------------------------------------------------- Permit ELECTRICAL PERMIT Additional desc 60AMPS TEMPORARY POLE Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL f / Ll CITY OF ATLANTIC BEACH, FLQRIDAil APPLICATION FOR ELECTRICAL,]PERMIT � TO THE CSF ELECTRUCAI.INSPECTOK DATE: If4FOIITANT?40TjC2; IN CONSIDERATION OF PERhGT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLO .WE HEREBY AGREE TO PMRFORM SAM WORT(IN ACCORDANCE WITH THE ATTACHED PLANS AND$MIFICATirjN$, ARE R PART NbItEOF, AND IN ACCORDANCE WTM THE ELECTRICAL RBOULATIONS.CODES AND CITY OF ATLANTICCH ORDINANCES. ELECTRICAL FIRM: MA ER ECTRICIAN; 1 hC AFI. OWNERS NAME: C �„ 4- ADDRESS: UL?�l a RF"OX_ BLDG.SIZE . BE N: _ RES.( ) APT.( ) COMM.( ) PUBLIC( ) INDUS.( ) NEW( ) OLD(J) REW.( } ADDITION( ) TRAILER( ) TEMP.( SIGNS( ) SQ.FT. SERVICE: NEW INCREASE REF C NDUCTOR SIZE AMPS: COPPER ALUM. pggg SWITCH OR BREAKER (06 AMP$ PH W VOLT SWAY EXIST, SERV,SIZE AMPS PH W I VOLT SWAY F13EDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL CEPTACLES CONCEALED OPEN TOTAL 0.30AMPS 3 i.I00 AIv>PS SWITCHES II'CANDESCENT FLOURESCENT&M.V. s FWD 0.100 AMPS, I OVER APPLIANCES BELL TRANSF. AIR H.P.RATING H.P.RATING I CEIL. KW-HEAT CONDITIONING COMP.MOTOR OTHER MOTORS AMPSI HEAT al OVER M TORS KP. VOLTAGE PHS NO. I H.P. V0LTA2 .j PHS SCELLANEOUS UNDER 600V OVER 600V XPANSFORMERS. NO. KVA NO. KVA N .NEON TRANSF. NO VA MA I MOTOR SIZE SWITCH FLASHE i EACH SIGN 41 Up&wd sa=m CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 r Application Number . . . . . 02-30023251 Date 10/09/02 Property Address . . . . . . 330 DUDLEY ST Application description . . . SINGLE FAMILY RESIDENCE Property Zoning . . . . . . . RESIDENTIAL GEN 2 FAMILY Application valuation . . . . 64342 Owner Contractor ------------------------ ----------- ------------- BEACHES HABITAT BEACHES HABITAT ------------ ---------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . INSTALL 11 FIXTURES Permit Fee . . . . 112 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 112 . 00 112 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 112 . 00 112 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. C BUILD G OFFICIAL CITY OF ATLANTIC BEACH APPLICATION FORPLUMBING PERMIT JOB LOCATION: Q u A` OWNER OF PROPERTY: �116-T TEL. PLUMBING CONTRACTOR: CONTRACTOR'S ADDRESS: 0, � STATE LICENSE NUMBER: (,�C..� S-6 4F 7 TEL. HOW MANY OF THE FOLLOWING FIXTURES RE-PIPED OR NEW SINKS SHOWERS --,2_LAVATORY _WATER HEATERS BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS -WASHING MACHINE FLOOR DRAINS SHOWER PANS _SEWER _WATER RE-PIPE (LIST FIXTURES BEING REPIPED) OTHER TOTAL FIXTURES: X $7.00+ $35.00= t MINIMUM PERMIT FEE: $35.00 SIGNATURE OF OWNER: SIGNATURE OF CONTRACTOR: �J INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS -(904) 247-5826. 330 DUDLEY Page 1 of 1 Harris, Patricia From: Ford, Don Sent: Wednesday, January 02, 2002 7:36 AM To: Harris, Patricia Subject: FW: 330 DUDLEY -----Original Message----- From: Walker, Chris Sent: Wednesday, December 26, 20011:36 PM To: Ford, Don Subject: 330 DUDLEY Don, They will have to pay for a water tap and a sewer tap. The sewer tap will cost them $ 1,200.00. You have the set price for a water tap it will be a long tap. Chris 1/3/02 CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address-3 -30 j�-j F—� Date Heated Sauare Footage oer Sn f Garages/She sq, D e Der s cr 10 TOTAL VALU t'-IT I )i '3 LVZ Tr;tal Valuation is t Remaining Vaiue per thousand or the--eot TOTAL BUILDING FEE F iL ling Fee Fireplaces BUILDINv PERMIT FEE S WATER IMPACT FEE SEWER IMPACT FEE J-0 WATER METER/`?'AP CAP ITRL ThPROVEMENT SEWSR% TAP ,12-1J) RADON (F-FS ' Cs05 SECTION h PAVING i'llyzRAUILIC SHARES CROSS CONNECTION S—' 61 SURCHARGE 15 01" 1 P H E R GRAND TOTAL DUE ADDITIONA-', PERMITS OR FEES; . w, min P.a P a a E 1 e c z.r c T emir S -ept-1c Tank We-. an F4nJ- s' F1 oar E , evat.L.on -L S u r"T f:--v Other CT -AL C.IU,1AATIONS and/ or NOTE',:'� : wD PROPERTY DESCRIPTION Lot # Block # 7 , Section # Ayet 1 Subdivision:J"�o, .� .A � Street Name '33 7-3 6) b DESCRIPTION OF WORK or Address: (If in a FLOOD HAZAR Flood Zone: area complete page 3) Brief Description j ��'y ��- � Jj Class of Work: (New/ Remodel/Addition: N ZONING INFORMATION Type of Construction: Zoning Proposed /2&-1 District: Use: 51 F&m�), Estimated Value $ Exceptions or Variances Materials: Granted: /y Solid or Filled / Ground: Roof: Method of Heating: OWNER INFORMATION Property Owner: ` Phone: Z 7— Mail Mailing Address G E Zip: 223 CONTRACTOR INFORMATION Contractor: Phone Mailing Address: Zip: Expiration STATE LICENSE NO: Date: I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL RULES, REGULATIONS, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. Owner Signature F/T 3� DATE Contractor Signature—#/:---. to DATE i4 SWORN TO AND SUBSCRIBED BEFORE ME BY THIS DAY OF NOTARY UBLIC �,. � Carol AMMrcello •is*My Commiss�w CC943449 P fiwpaws June OB,2 WATER IMPACT FEE WORK 314EET ADDRESS:— '3 3 Q a p L y , , I3r-- DRAINAGE FIXTURE UNIT FIXTURE TYPE VALUE AS LOAD FIXTURES UNITS Automatic clothes washers, commercial 3 Automatic clothes washers, residential 2 Bathroom group consisting.of water closet, lavatory, / bidet, and bathtub or shower 6 Bathtub (voth or without overhead shower or whirlpool attachments) 2 Bidet 2 Combination sink and tray 2 Dental lavatory 1 Dishwashing machine, domestic 2 Drinking fountain 1/2 Floor drains 2 Kitchen sink, domestic 2 Kitchen sink, domestic with food waste grinder and/or dishwasher 2 Laundry tray 1 or 2 compartments 2 Lavatory 1 Shower compartment, domestic 2 Sink 2 Urinal 4 Urinal, 1 gallon per flush or less 2 Wash sink (circular or multiple) each set of faucets 2 Water closet, flushometer tank, public or private 4 Water closet, private installation 4 Water closet,public installation 6 TOTAL NUMBER OF UNITS MULTIPLIED x 20 TOTAL$ FO PLAN REVIEW CHECKLIST PROPERTY DESCRIPTION: OWNER: [ ] 1. Determine Occupancy Classification of the structure. Select occupancy classification which most accurately fits the use of the Building. (Chapter B3) [ ] 2. Determine actual physical properties of building. [ ] a. Determine building area each floor. (Area definition Chapter B2) [ ] b. Determine grade elevation for building. (Grade definition Chapter B2) [ ] C. Determine building height in feet above grade. (Height definition Chapter B2) [ ] d. Determine building height in stories. (Story definition Chapter B2) [ ] e. Determine separation distance from exterior walls to assumed and common property lines. (Property line definition Chapter B2) [ ] f. Determine percent of exterior openings per floor. [ ] 3. Determine minimum Type of Construction necessary to accommodate proposed structure. (Chapter B6) [ ] a. Determine maximum allowable heights and floor areas for Types of Construction and Occupancy classification. (Table B500) [ ] b. Check allowable height and area increases permitted. (Chapter B5) ( ] 4. Check detailed Occupancy requirements. (Chapter B4) [ ] 5. Check detailed Construction requirements [ j a. Fire Protection of Structural Members (Chapter B6&Table B600) [ ] b. Fire Protection Requirements(Chapter B7 and Table 8700) [ ] C. Means of Egress Requirements(Chapter B10) [ ] d. Special restrictions if in Fire District. (Appendix BF The provisions of Appendix BF are applicable only where specifically adopted by Ordinance) [ ] 6. Review design as related to standards. (Chapters B16-B26) [ ] 7. Check other requirements as necessary. [ j a. Construction projecting into public property(chapter B32) [ ] b. Elevators and conveying systems(Chapter B30) [ ] C. Sprinklers, standpipes and alarm systems(Chapter B9) [ ] d. Use of combustible materials on the interior(Chapter B8) [ ] e. Roofs and roof structures (Chapter B15) [ ] f. Light,ventilation and sanitation (Chapter B12) [ ] g. Other CITY OF ATLANTIC BEACH BUILDING DEPARTMENT Date By: Don C. Ford, Building Official don/sb.1 PRE-APPLICATION REVIEW SUBMITTAL City of Atlantic Beach- 800 Seminole Road- Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • FAX (904)247-5805• http://www/ci.atlantic-beach.fl.us Pre-Application Number: SF-2001-08 Date Routed: 12-05-01 Project Name: 330 Dudley Street (Habitat) Submittal No. 1 ❑ Commercial ❑ Multi-Family ® Single-Family ❑ Other Departments Routed: ® Building (Don Ford 247-5813) lLKPlanning and Zoning (Sonya Doerr 247-5817) Public Works (Bob Kosoy 247-5878) ublic Utilities (Donna Kaluzniak 247-5834) ❑ Other Date Review Comments Due: Tuesday, December 12, 2001 Additional Information: Please enter any comments in the appropriate department folder. (F:\Development Review Comments\) If your department has no comment on this submittal, please enter "reviewed, no comment" by the date comments are due, or it will be assumed your department has no comment. SF-2001-08 330 Dudley Street (Habitat new SF ) December 11, 2001 Pre-Application Number: SF-2001-08 Date Due: 12/12/01 Public Works Dept. Plan Review for 330 Dudley Street (Habitat) Reviewed, no comments. Plans returned to Building Dept. on 12/12/01. Atlantic Beach — Utility Dept. No comments on SF-2001-08. No water/sewer information shown. Water& sewer is located in the area. Donna Kaluzniak 12/6/01 Planning and Zoning Reviewed; complies with zoning district and setbacks. sbd/12/06/01 0 PRE-APPLICATION REVIEW SUBMITTAL City of Atlantic Beach• 800 Seminole Road• Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800• FAX (904)247-5805• http://www/ei.atlantic-beach.fl.us Pre-Application Number: SF-2001-08 Date Routed: 12-05-01 Project Name: 330 Dudley Street (Habitat) Submittal No. 1 ❑ Commercial ❑ Multi-Family ® Single-Family ❑ Other Departments Routed: ® Building (Don Ford 247-5813) ® Planning and Zoning (Sonya Doerr 247-5817) ® Public Works (Bob Kosoy 247-5878) ® Public Utilities (Donna Kaluzniak 247-5834) ❑ Other Date Review Comment Additional Informatio folder. (F:\Developme CA� If your department h _12MUpiC by the date comment. 3 Atlantic Beach—Utility Dept. No comments on SF-2001-08. No water/sewer information shown. Water & sewer is located in the area. Donna Kaluzniak 12/6/01 vz) !�_� .J F4r, PROPERTY DESCRIPTION Lot # G Block # , Section # Subdivision n, ►;T 4" � ��"�` � G "'- Street Name ] DESCRIPTION OF WORK or Address: (If in a FLOOD HAZAR Flood Zone: area complete page 3) �-' g-�i� Brief Description 5 � ��C= M I ''�► Class of Work: (New/ Remodel/Addition: /U ZONING INFORMATION Type of Construction: Zoning / Proposed District: ! Use: ) Estimated Value $ 4'1 , Exceptions or Variances Materials: Granted: G Solid or Filled Ground• x�l L Roof: Method of Heating: OWNER INFORMATION Property Owner: • Phone: 2 7— Mailing Address � Zip: 97_2- '3 CONTRACTOR INFORMATION Contractor: S Phone: Mailing Address: Zip: Expiration STATE LICENSE NO: Date: I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL RULES, REGULATIONS, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. Owner Signature n DATE //lu / Contractor Signature DATE l/ Z � r� SWORN TO AND SrUBSCRIBED BEFORE ME BY THIS ot+� DAY OF 0 NOTARY UBLI C Carol A M&M000 i�4 t,�;i*my Commissj*n CCS43413 :,„„r” ENpirea June 08,2004 304814 MAP SHOWING SURVEY OF LOT 2, BLOCK 2, LEWIS SUBDIVISION, AS RECORDED IN PLAT BOOK 24, PAGE 92 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 4 4V4/11 t/NK FENIE 721 L/NE /=�,e�^/p�L%Roj✓ � . FddND%2"/.tem P/iE -_ AME (.vo 250.00 .4'PNA/N i L/NK FENCE—.�,� N Or °od o K: LOT 3 cor i �� BLOCK Z VACANT BLOCK Z Q O � C.J Q )'eo^' 4.41E -vye 'T" 50.00 CUA/AI L/NK f4wee �,�,p�fl7Tcv P4rzr o/— 5.t-47T/OW 17 NOTES: 1) THIS IS A BOUNDARY SURVEY. 2) NO BUILDING KESTRICTION LIN�: .SHOWN ON PLAT, 4) BEARINGS ARE BASED ON THE SOUTH THERE ARE RESTRICTION LINES BY ZONING AND RIGHT-OF-WAY LINE OF DUDLEY THERE MAY BE EASEMENTS THAT AFFECT THIS STREET AS BEING DUE EAST BY PLAT. PROPERTY THAT ARE RECORDED IN THE PUBLIC RECORDS OF THIS COUNTY THATYARE NOT SHOWN ON THIS SURVEY._ 3) THIS PROPERTY LIES IN FLOOD ZONE 'T' WHICH IS THE AREA DETERMINED TO BE OUTSIDE THE PREPARED FOR THE BENEFIT OF. 500 YEAR FLOOD ACCORDING TO FEMA FLOOD CInd tlantic Beach t1 Planninoning Department This approval vs c omplienc a with applicable y J zoning, subdiand other local land development rens, but does not constitute approval for thece of permits. Compliance with FI 'da Builode and all other applicable local, ate and rat permitting requirements must b verified lure of the it•of Atlantic Beach uilding prior to the ' u nce of Buildin Permit oil By: Comnity velopment D ector Date: z 4 e 1 1 ^ � k i i j... ; it f Z a D 5 c �z� 1 Wq 1 f HOLMESLUMBER TRUSS CO . 6550 Roosevelt Blvd. Jacksonville, FL 32244 Phone (904) 772-6100 Fax(904) 772-1973 JOB CUSTOMERC LOCATION ID v D G ey .S 7' BUILD SET I. Truss Takeoff II. Layout' III. Engineering IV. Framing Details V. Simpson Strong-Tie Hanger Details VI. HIB-91 Summary Sheet Holmes Lumber Co. Policy re:Repair,correction or rebuilding of faulty trusses. This company is not liable or subject to any backcharges levied against it by a customer unless that customer so notifies Holmes Lumber in writing of the existing problem and allows Holmes Lumber a reasonable amount of time to correct, alter or remake the truss or trusses to solve the existing problem. 24" OC THRU T5 TO FACE OF T1 F® 42 ' ^I 38 I w N J4 .14 01) CY) J2- J 1Em �C Ul J5 J4 N N m C 00 07 J2 C J2 J3 J3 'y J4 J4 4ct,- wc- ® i 38 ' _I �� 24" OC THRU T5 Job: (9-0691) LOT 11 T1 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP 01 Dense : T2 2x6 SP 02 N: 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #1 N ENCLOSED BLDG, LOCATED ANYWHERE IN ROOF, WEBS 2x4 SP #3 WIND TC OL = 5.0 PSF, WIND BC DL - 5.0 PSF. RECOMMENDED CAMBER 3/8" AT MIDSPAN BETWEEN BEARINGS. #1 HIP DESIGNED TO SUPPORT 07-00-00 JACKS WITH NO WEBS. A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. W5X12 W X3 W5 12 T 5p m m mti m W4X7(A2) W4X7(A2) _ ---IVB, „z W1.5X4 HS412 W1.5X4 28' f--2 2B' 2 --I 7' 14' 7' 432# 432# Rv=2129# U=1030# W=3"B Rv=2129# U=1030# W=3"B TAG = T1 SEQ = 56143 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 2 PLIES= 1 TOTAL= 2 REV. 18.2c4 SCALE =0.2424 ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REWIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF *IMPORTANT**SHALL NOTBE RESPONSIBLE FOR ANY ARNING IN HANDLING, ERECTION AND DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN cT per_ TC DL 7•0 PSF DATE 03/11/99 FAILURETOBUILDTHE TRUSS IN CONFORMANCE WITH OSTB8 BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING REot ALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM OUIREMENTS. UNLESS OTHERWISE INDICATED, TOP °t 42319 A BC DL 1 0 •0 PSF DRWG A446 GR 8 EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD 6C LL 0 •0 PSF JDM CONNECTORS PEP DRAWINGS 130, 150 6 16OA-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING -- SEE 5+A r E 0-F W CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER 9�°.F <Og10'oc e TOT.L D. 37 .0 PSF 0/A LEN. 2 8 SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �'' +r OUR.FAC. 1 . 25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN 70 THE TRUSS ERECTION CONTRACTOR. rs/•cn-D oE1,1�jS •--TPI - TRUSS PLATE INSTITUTE NOS - 1991 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION "YC SPACING See a b o v e T VPE h i os Job: 9-0691 LOT 11 T2 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 8.50 FT FROM ROOF EDGE. WEBS 2x4 SP #3 WIND TC OL = 5.0 PSF, WIND BC OL = 5.0 PSF. A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. 10' 8' W4X5(R) W X4 W4X R)it T 12 1 5 L-- W1.5X3 W1.5X3 v vv W3X5(A1) W3X5(A1) 8 1 '2 W3X7 W3X4 W3X7 28' Rv=1144# U=590# W=3"8 Rv=1144# U=590# W=3"8 SEG = 56147 PLATE-WAVE TPI95 TPI-95 (STD) OTY= 2 PLIES= 1 TOTAL= 2 REV. 1B.2c4 SCALE =0.2424 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REQUIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF t *IMPORTANT** SHALL NOT BE RESPONSIBLE FDR ANY ARNING IN HANDLING, ERECTION ANODEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN 5 ` p�_ TC DL 7 .0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTB6 BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING REF� BC DL 10 0 PSF DRWG ALPINECONnECTOFIS aRE MADE OF 20GA GALV. STEEL MEEtInG ASTM OUIREMENiS. UNLESSO7MERNISE INDICATED, TOP `E 42319�fA446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER T BC L L 0 0 PSF JDM TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD CONNECTORS PER DRAWINGS 130, 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING -- SEE s T A TE 0'F W 4 TOT.LD. 37 .0 PSF 0/A LEN. 28 CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER C`:�* 40R L0 Q. SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �',fsT�r o'�Z DUR.FAC. 1 .25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR, Fr.�_ ET,T('j x--TPI - TRUSS PLATE INSTITUTE NDS 1991 NATIONAL SIGN SPECIFICATION FOR WOOD CONSTRUCTION "T[U SPACING 2'4 �rTYPE h i p s Job: (9-0691) LOT 11 T3 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP 02 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 8.50 FT FROM ROOF EDGE. WEBS 2x4 SP #3 WIND TC OL - 5.0 PSF, WIND BC DL = 5.0 PSF. A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. 6 11 -----� WAX5(R) WAX6 T 12 T 5 p WI 5X3 W1.5X3 v v W3X5(A1) W3X5(A1) W W2 3X7 W3X4 W3X4 28' �—2 28 2 Rv=1144# U=580# W=3"8 Rv=1144# U=580# W=3"8 TAG = T3 SED = 56151 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 2 PLIES= 1 TOTAL= 2 REV. 18.2c4 SCALE =0.2424 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REQUIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF *IMPORTANT** SHALL NOT BE RESPONSI8LE FOR ANYWARNING IN HANDLING. ERECTION AND o DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN s T M_ TC DL 7.0 PSF DATE 03/11/99 �1 \\UvAV�AV\ FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE Q�� .1 ALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM GUIREMENTS. UNLESS OTHERWISE INDICATED. TOP ct g2319'F `lam BC DL 1 0 •0 PSF DRW G O A446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER p TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING, BOTTOM CHORD BC LL 0 .0 PSF JD M CONNECTORS PER DRAWINGS 130. 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE s r A t E as v OT.LO. 37 .0 PSF D/A LEN. 28 [DUR. CONFORM./APPLICABLE PROVISIONS OF NDS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE 17/1/911 FOR PROPER .Q <ORIO Q. SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS ��'j f' o H FAC. 1 .25 IN ONLY, ANO SHALL NOT BE RELIED UPON IN ANY OTHER MAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR•--TPI - TRUSS PLATE INSTITUTE NOS - i 91 NATIONAL ESI GN SPE IFICATI N F WOO CONSTRUCTION PACING 24.0" TYPE hips Job: 9-0691 LOT 11 T4 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND. 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 8.50 FT FROM ROOF EDGE. WEBS 2x4 SP #3 WIND TC OL = 5.0 PSF, WIND BC OL = 5.0 PSF. A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. 13' -�- 2' 13' —-1 W4X5(R) W4X W3X4 W3X4 5 p 12 _ al m in in v W3X5(AI) W3X5(AS) W1.5X3 W3X7 W3X4 W1.5X3 W3X4 28' �--2 282 --� Rv=1144# U=5BO# W=3"B Rv=1144# U=580# W=3"8 TAG = T4 SEQ = 56155 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 2 PLIES= i TOTAL= 2 BEV. 1B.2C4 SCALE =0.2424 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REGUIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF *IMPORTANT**SHALL NOT BE RESPONSIBLE FOR ANYWARNING IN HANDLING, ERECTION AND [FAILURE EVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN �r� T Jam. TC DL 7 •0 PSF DATE 03/11/99 TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI, FOR ADDITIONAL SPECIAL PERMANENT BRACING RELPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM OUIREI NTS. UNLESS OTHERWISE INDICATED. TOP 1 2319f � BC DL 10 •0 PSF DRWG 446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPERRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN. POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD BC L L 0 •0 PSF JDM CONNECTORS PER DRAWINGS 130. ISO 6 16OA-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE 5 T A T E Of ,^ TOT.LD. 37 •O PSF 0/A LEN. 28 CONFORM W/APPLICABLE PROVISIONS OF NDS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE 17/1/911 FOR PROPER SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �' F1, .wo`'� �e DUR.FAC. 1 .25 JN ONLY, AND SHALL NOT BE RELIED WON IN ANY OTHER NAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR. Tjryo EZ •--TPI - TRUSS PLATE INSTITUTE NOS 991 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SPACING 24.0" TYPE hips Job: (9-0691) LOT 11 T7 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N ***LOADING ON THIS TRUSS CALCULATED BY TRUSS FABRICATOR*** BOT CHORD 2x4 SP #2 N WEBS 2x4 SP #3 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WIND TC DL = 5.0 PSF, WIND BC DL = 5.0 PSF. LOAD CONTINUOUS LOADS LOAD CONC. LOADS CASE SIDE L-PLF R-PLF START END CASE SIDE MAG X-LOC A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. 0 T 54.0 54.0 0.0 5.0 0 T 51 2.6 MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. 0 8 20.0 20.0 0.0 5.0 0 B 44 2.6 1 B 1.B 1.8 0.0 5.0 1 T -81.1 -B1.1 0.0 2.5 1 T -81.1 -81.1 2.5 5.0 -- 2'6"12 511 2'5"4 2.6" 2.6" W4X4 12 5 � m rn v v W2X4(A1) T B 5' 5' W1.5X3 2'6"12 2'5"4 44 Rv=231# U=200# W=3.8 Rv=234# U=200# W=3"B TAG = T20 SEQ = 56194 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 1 PLIES= 1 TOTAL= 1 REV. 18.2c4 SCALE =1 .4002 ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REGUIRE EXTREME CARE *IMPORTANT*)( SHALL NOT BE RESPONSIBLE FOWARNING ANY IN HANDLING. ERECTION AND 03/11/99 T C LL 20 .0 PSF REF 1 \ DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN V-S T pn_ TC DL 7.0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OST88 BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE "�9 ALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL NEEIING ASTM OUIRENENTS. UNLESS OTHERNISE INDICATED. TOP d23f9f �l� BC DL 10 .0 PSF DRWG A446 GR 8 EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN. POSITION LY ATTACHED PLYWOOD SHEATHING, BOTTOM CHORD BC LL 0 .0 PSF JDM CONNECTORS PER DRAWINGS 130. 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE S T A r E os „ 3 7•0 PSF DEQ LEN. 5 TOT.LD. CONFORM W/APPLICABLE PROVISIONS OF NDS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER S + <ORTO SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS Frr '"off DUR.FAC. 1 .25 IN ONLY. AND SHALL NOT BE RELIED UPON IN ANY OTHER NAY, DESIGN TO THE TRU55 ERECTION CONTRACTOR, Cr`r/F ,D AEjt x--TPI - TRUSS PLATE INSTITUT NDS 1991 NATI A SIGN SPE IF AT10N FOR M LONS TRUCTI SPACING see above TYPE c o m n Job: 9-0691 LOT 11 J1 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 8.50 FT FROM ROOF EDGE. WEBS 2x4 SP M2 N WIND TC DL = 5.0 PSF, WIND BC DL = 5.0 PSF. THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. REACTION OF 157,09. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv-157N NAILED 11'0"6 m m m 12 m 5p W2X4(AS) 4'1 B'1"2 7'1"8 Rv=399N U=240# W=3"8 Rv-70# U=200* NAILED TAG = T17 SEG = 56164 PLATE-WAVE TPI95 TRI-95 (STD) QTY= 16 PLIES= 1 TOTAL= 16 REV. 16.2c4 SCALE =0.7740 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REGUIRE EXTREME CARE 03/11/99 TC LL CO 0 PSF REF *IMPORTANT** SHALL NOT BE RESPONSIBLE FOR ANY WARNING IN HANDLING. ERECTION AND + \ DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN ss'71cp�_ TC OL 7.0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTB8 BY TPI. FON ADDITIONAL SPECIAL PERMANENT BRACING RE —'9 ALPINE CONNECTORS ARE MADE OF 206A GALV. STEEL MEETING ASTM DUIREMENTS. UNLESS OTHERWISE INDICATED, TOP '4;1 F�� BC DL 1 0 .0 PSF DRWG \U\\ A446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING, BOTTOM CHORD BC LL 0 .0 PSF JDM CONNECTORS PER DRAWINGS 130. 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE S T A T E OF CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE 17/1/91) FOR PROPER 9. 9�F<PRto' T 0 T,L D. 37 .0 PSF O/A LEN. 7 SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �',fs Frr o'4 A C. 1 .25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN 70 THE TRUSS ERECTION CONTRACTOR. 1.c,.__ ET,1('jS A--TPI • iRU55 P ATE INSTITUTE NOS - 1991 NATIONAL DESIGN SPECIFICATION FOR WOO CONSTRUCTION �"�tL1 SPACING 2 4 O�� T YP E spec Job: (9-069 1LOT 11 J2 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WEBS 2x4 SP #2 N WIND TC OL = 5.0 PSF, WIND BC OL - 5.0 PSF. THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. REACTION OF 99.64. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv=100# NAILED 10'2"6 TU 12 fU 5 p W2X4(AS) v B'i"2 2' 5' Rv=334# U=220# W=3"B Rv=441# U=200# NAILED TAG = T7 SEG = 56168 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 8 PLIES= 1 TOTAL= 8 REV. 18.2c4 SCALE =0.9735 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REWIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF M IMP 0 R T A N T** SHALL NOT BE RESPONSIBLE FOR ANYWARNING IN HANDLING. ERECTION AND n \ DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN c, T per. TC DL 7.0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE ALPINE CONNECTORS APE MADE OF 20GA GALV. STEEL MEETING ASTM OUIREMENTS. UNLESS OTHERWISE INDICATED. TOP gz31gF BC OL 10 .0 PSF DRWG A446 GR 8 EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD BC LL 0 •0 PSF JDM CONNECTORS PER DRAWINGS 130, 150 6 1GOA-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING -- SEE s T"r E o r; TOT.L D. 37 .O PSF D/Q LEN. 5 CONFORM M/ppPL ICABLE PROVISIONS OF NDS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER "�'.�4 TOR tG Q. SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THISOUR.FAC. 1 .2 5 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR. sT E 'L .1 "--TPI " TRUSS PLATE INSTITUTE NOS " 1991 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SPACING 2 4.o- T YPE s p e c Job: (9-0691) LOT-11 J3 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WEBS 2x4 SP #2 N WIND TC DL - 5.0 PSF, WIND BC DL - 5.0 PSF. THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. REACTION OF 27.62. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv=280 NAILED 9'4"6 12 W2X4(A1) 5 T Q e•1••z �-— 2' 3, Rv=288# U=220# W=3"8 Rv=17# U=20011 NAILED TAG = T18 SEG = 56173 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 8 PLIES= 1 TOTAL= 8 REV. 18.2c4 SCALE =1 .3116 ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REQUIRE EXTREME CARE 03/11/99 T C LL 20 .0 PSF REF *IMP0RTANT** SHALL NOT BE RESPONSIBLE FOR ANY ARNING IN HANDLING, ERECTION ANO ,rDEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN cT M. TC DL 7 •0 PSF DATE 03/11/99 ut FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OST8B BY TPI. FOR AOOITIDNAL SPECIAL PERMANENT BRACING RE ALPINE CONNECTORS ARE MADE OF 206A GALV. STEEL MEETING ASTM GUIREMENTS. UNLESS OTHERWISE INDICATED. TOP ` 42319rf �� BC DL 10 .0 PSF DRWG A446 GR 8 EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD BC LL 0 .0 PSF JD M CONNECTORS PER DRAWINGS 130. 150 6 160A-F, DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE 5 T A T E OF CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE 17/1/911 FOR PROPER Zk�.��Dg10'q�- Q, TOT.L O. 37.0 PSF D/A LEN. 3 SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �'f E+r �"' DUR.FAC. 1 .25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER MAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR. .--TPI --TRUSS PLATE INSTITUTE MDS • 1991 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION "'1tU SPACING 24.0" TYPE spec Job: 9-0691 LOT 11 J4 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N AN UPLIFT REACTION OF -156# OCCURRED ON A BOT CHORD 2x4 SP #2 N NON-WIND LOAD CASE. SPECIAL CONNECTION OR HANGER IS REQUIRED. WEBS 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, ENCLOSED BLDG, LOCATED ANYWHERE IN ROOF, THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM WIND TC DL = 5.0 PSF, WIND BC DL - 5.0 PSF. REACTION OF 317.16. A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. CONTRACTORS WARNING: MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. 2x4(A i) B'6"6 12 c 5 � 8' 1"2 1'1"8 2 Rv=3570 U=250# W=3"8 Rv-%*15lA620(NRILNMLED TAG = T9 SEQ = 56186 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 12 PLIES= 1 TOTAL= 12 kEV. 18.2c4 SCALE =1 .9005 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REGUIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF t *IMPORTANT** SHALL NOT BE RESPONSIBLE FOR ANY ARNING IN HANDLING, ERECTION ANO DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN cT M. TC OL 7•0 PSF DATE 03/11/99 FAILURE TOBUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FDR ADDITIONAL SPECIAL PERMANENT BRACING RE 10 .0 ALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM GUIREMENTS. UNLESS OTHERWISE INDICATED. TOP 42319` iBC DL 1 0 •0 PSF DRWG A446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER T BC LL 0.0 PSF JDM TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING, BOT70M CHORD CONNECTORS PER DRAWINGS 130, 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING -- SEE 5 T A`E'' TOT.L D. 37 .0 PSF 10/A LEN. 1 CONFORM N/APPLICABLE PROVISIONS Of NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER '.��foR 1� uv Q, SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS �',r Err , DUR.F Ac. 1 .25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUSS ERECTION CONTRA-'-. Sl�fO of t •--TPI - TRUSS PLATE INSTITUTE NOS - 1991 NATIONAL ESIGN SPECIFICATION FOR WOO CONSTRUCTION SPACING 2 4 " TYPE spec Job: 9-0 91 LOT 11 J5 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI. BOT CHORD 2x4 SP 112 N ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WEBS 2x4 SP 112 N WIND TC DL - 5.0 PSF, WIND BC DL - 5.0 PSF. THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. REACTION OF 17.07. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv=6N NAILED 9114 rn m v o W2X4(A1) 12 5 C7 T Q 8'1"2 2'7"8 2' 2'6" Rv-276N U=21011 W=3"8 Rv-S1N U=20011 NAILED PLATE-WAVE TPI95 TPI-95 (STD) QTY= 1 PLIES= 1 TOTAL= 1 bEV. 18.204 SCALE =154364 ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REQUIRE EXTREME CARE 03/11/99 TC LL 20 .0 PSF REF t *IMP0RTANT** SHALL NOT BE RESPONSIBLE FDR ANY ARNING IN HANDLING, ERECTION ANpDEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN cT M. TC OL 7 •0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS 1N CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE ,� 10 .0 O\\\ ALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM GUIREMENTS. UNLESS OTHERWISE INDICATED, TOP "%2;31 BC DL 10 •0 PSF DRWG A446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING, BOTTOM CHORD BC LL 0 .0 PSF JDM CONNECTORS PER DRAWINGS 130. 150 6 16OA-F. DESIGN STANDARDS WITH PROPERLY ATTLRITSIDEILING -- SEE sT r E P RCONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL 1) FORPROPERR � T 0T.LD. 37 .O PSF 0/A LEN. 20600 SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATICOPY OF THIS �' f� �` DUR.FAC. 1 •25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUONTRACTOR. Sl S`•--TPI - TRUSS PLATE INSTITUTE N S" 1991 NATIONA ESIGN SPE IF CATI N F TION SPACING 24.0" TYPE spec Job: 9-0691 LOT 11 J6 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N ***LOADING ON THIS TRUSS CALCULATED BY TRUSS FABRICATOR*** BOT CHORD 2x4 SP #2 N WEBS 2x4 SP #3 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WIND TC OL = 5.0 PSF, WIND BC DL = 5.0 PSF. LOAD CONTINUOUS LOADS LOAD CONC. LOADS CASE SIDE L-PLF R-PLF START ENO CASE SIDE MAG X-LOC THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM 0 T 54.0 54.0 0.0 12.7 0 T -314 3.5 REACTION OF 260.94. 0 B 20.0 20.0 2.8 12.7 0 T 28 6.3 1 B 1.8 1.8 2.8 12.7 0 T 100 9.1 A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. 1 T -74.4 -74.4 0.0 3.0 0 B -37 3.5 MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. 1 T -33.1 -33.1 3.0 9.7 0 B 17 6.3 1 T -74.4 -74.4 9.7 12.7 0 B 44 9.1 CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv=146# NAILED 1 5"7 -31 / 2'9"15 28- - 2'9"15 100 -2'9"8 �- 9'10"13 �11 09 W3X3 W1.5X3 M 3.54 p '^ m m W2X4(A1) vT 8' "2 1 9'10"13 �- 2'9"15 9'10"13 1'5"7--}- 2'9"15 2.9"15 2'9"8 -37# 17J 44 Rv=317# U=270# W=4"15 Rv=261! U=200# NAILED TAG = T6 SEQ = 56198 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 4 PLIES= i TOTAL= 4 PEV. 18.2c4 SCALE =0.5915 ALPINE ENGINEERED PRODUCTS. INC. TRUSSES REQUIRE EXTREME CARE 03/11/99 T C LL 20 .0 PSF REF t MIMP0RTANTH* SHALL NO1 BE RESPONSIBLE FOR ANY A RN I N G IN HANDLING• ERECTION ANDDEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS. OR ANY BRACING. SEE HIB-9f BY TPI. SEE THIS OESIGN cT q�_ TC OL 7 .0 PSF DATE 03/11/99 FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING REALPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM OUIREMENTS. UNLESS OTHERWISE INDICATED, TOP °`42319` I� BC DL 10 0 PSF DRWG CHORE)GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHOSHALL BE LATERALLY BRACED WITH PROPER TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD BC LL 0 •0 PSF JD M CONNECTORS PER DRAWINGS 130, 150 6 160A-F. DESIGN STANDARDS WItH PROPERLY ATTACHED RIGID CEILING -- SEE 5 T A T E 0 F CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER <ORT�' - T 0 T.L D. 3 7 .O PSF 0/A LEN. 91013 SEAL ON THIS DRAWING APPLIES i0 THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THISC,f��f, . . �y DUR.FAC 1 25 IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY, DESIGN TO THE TRUSS ERECTION CONTRACTOR. S"�A`.._D BET,jGti "--TPI • TRUSS PLATE INSTITUTE NOS - 1991 NATIONAL ESI N SPE 1FICATjON FOR ND CONSTR TION �^2 SPACING S e e a b o v e TYPE spec Job: (9-0691) L 0 T 11 J7 THIS DWG. PREPARED BY THE ALPINE OB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI, BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 4.50 FT FROM ROOF EDGE. WEBS 2x4 SP #2 N WIND TC DL = 5.0 PSF, WIND BC DL - 5.0 PSF. THERE WERE 2 NAIL BEARINGS WITH A MAXIMUM A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24" O.C. REACTION OF 22.42. MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD. CONTRACTORS WARNING: THIS TRUSS IS DESIGNED TO BEAR AND/OR SUPPORT ADDITIONAL LOADS AT SPECIFIC LOCATIONS. PARTICULAR CARE IS ADVISED DURING INSTALLATION TO ENSURE THAT THIS TRUSS IS ERECTED PROPERLY. Rv=22# NAILED 9' "13 m rn c Q 0 W2X4(A 1) 3.54 v 8' "2 -3'7"15 2'9"15 3'6"7 Rv=376# 1=310# W=4"15 RY-16# U=200# NAILED TAG = T21 SEQ = 56190 PLATE-WAVE TPI95 TPI-95 (STD) QTY= 2 PLIES= 1 TOTAL= 2 REV. 16.2c4 SCALE =1. 1280 ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REGUIRE EXTREME CARE 03/11/99 TC LL 20 0 PSF REF t I MPORT ANT**SHALL NOT BE RESPONSIBLE FOR ANY ARNING IN HAMMING. ERECTION ANO 7 .0 PSF DATE 03/11/99 [FAILURE EVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN 5 T Rn. TC DL TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE ` 1LPINE CONNECTORS ARE MADE OF 20GA GALV. STEEL MEETING ASTM GUIREMENTS. UNLESS OTHERWISE INDICATED, TOP o 423 9' lBC DL 10 •O PSF DRWG 446 GR B EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL DE LATERALLY BRACED WITH PROPER RUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN. POSITION LY ATTACHED PLYWOOD SHEATHING. BOTTOM CHORD BC LL 0 .0 PSF JDM CONNECTORS PER DRAWINGS 130, 150 6 160A-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING-- SEE s T•*a or^^ CONFORM W/APPLICABLE PROVISIONS OF NOS 6 TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/91) FOR PROPER °��+<OgIO'o�-hQ. [DUR. OT.LO. 37 .0 PSF OSA LEN. 30607 SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS FAC. 1 .25 IN ONLY, ANO SMALLNOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR. S/kT., jS• TPI - TRUSS PLATE INSTITUTE NOS - 1991 NATIONA DESIGN SPECIFICAT FOR WO DCONSTRUCTION PACING 24.0" TYPE spec SINGLE FAMILY RESIDENCE HVAC LOAD ANALYSIS fo r Beaches Habitat P.O. Box 50939 Jacksonville, FL 32240 oftwale RRmUNIALHVAC. HVAC LOAM Prepared By: Jeri Boxx Ocean State Heating&Air Conditioning 1476 Atlantic Boulevard Neptune Beach,FL 32266 (904)249-8251 06-29-00 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach, FL 32266-1798 06-29-00 Page 2 Project Summary Project: Single Family Residence Company: Ocean State Heating &Air Conditioning Client: Beaches Habitat Representative: Jeri Boxx Address: P.O. Box 50439 Address: 1476 Atlantic Boulevard City: Jacksonville,FL 32240 City: Neptune Beach, FL 32266 Phone: 241-1222 Phone: (904) 249-8251 Fax: Fax: (904) 249-8949 Design Data Project Name: Single Family Residence Reference City: Jacksonville, Florida Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 Feet Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factgr: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 27 N/A N/A 72 N/A Summer: 96 78 50% 75 51 Check Figures Total Building Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 Building Loads Total heating required with outside air: 25,232 Btuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible + latent) 1.930 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,June 29,2000 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach,FL 32266-1798 06-29-00 Page 3 Total Building Summary Loads Component Area Sen. Lat. Sen. Total Description Quart Loss Gain Gain Gain 3C Window Double Pane Clear Glass etal Frame 150 4,894 0 6,728 6,728 10D Door Wood Solid Core 38 787 0 430 430 12C Wall R-11 + 1/2"Gypsum(R-0.5) 934 3,783 0 2,068 2,068 13C Part R-11 + 1/2"Gypsum(R-0.5) 64 130 0 92 92 16G Ceiling R-30 Insulation 1,214 1,802 0 1,802 1,802 22A Slab on Grade No Edge Insulation 149 5,431 0 0 0 Subtotals for structure: 2,549 16,827 0 11,120 11,120 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 2,400 2,400 Lighting: 0 0 0 0 0 Ductwork: 0 1,202 0 1,622 1,622 Infiltration: Winter CFM: 145.6, Summer CFM: 64.7 188 7,203 2,255 1,494 3,749 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,836 Temperature Swing Multiplier: X1.00 Building Load Totals: 25,232 3,175 17,836 21,011 Check Figures Total Building Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 Building Loads Total heating required with outside air: 25,232 Stuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible + latent) 1.930 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday.June 29.2000 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach, FL 32266-1798 06-29-00 Page 4 System #1 Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 150 4,894 0 6,728 6,728 10D Door Wood Solid Core 38 787 0 430 430 12C Wall R-11 + 1/2"Gypsum(R-0.5) 934 3,783 0 2,068 2,068 13C Part R-11 + 1/2"Gypsum(R-0.5) 64 130 0 92 92 16G Ceiling R-30 Insulation 1,214 1,802 0 1,802 1,802 22A Slab on Grade No Edge Insulation 149 5,431 0 0 0 S u btota Is fo r stru ctu re: 2,549 16,827 0 11,120 11,120 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 2,400 2,400 Lighting: 0 0 0 0 0 Ductwork: 0 1,202 0 1,622 1,622 Infiltration: Winter CFM: 145.6, Summer CFM: 64.7 188 7,203 2,255 1,494 3,749 Ventilation:Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total 17,836 Temperature Swing Multiplier: X1.00 System Load Totals: 25,232 3,175 17,836 21,011 Check Figures Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 System Loads Total heating required with outside air: 25,232 Btuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible + latent) 1.930 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,June 29,2000 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach, FL 32266-1798 06-29-00 Page 5 Room Load Summary Reports System #1 Room Load Summary Htg ; Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 1 Bedrms 322 5,283 69 0-0 0 3,637 820 165 1.00 165 165 2&3 2 Bedrm4 322 7,808 101 0-0 0 5,145 950 234 1.00 234 234 Living 3 Bedrm1 322 4,517 59 0-0 0 2,963 482 135 1.25 169 135 Bath 4 Kitchen 248 7,624 99 0-0 0 6,091 923 277 1.00 277 277 Dining System 1 1214 25,232 328 17,836 3,175 811 845 811 Totals Main Trunk Size: 12x12 in. System #1 Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.751 85%/15% 17,836 3,175 21,011 Recommended: 1.930 77%/23% 17,836 5,328 23,164 System #1 Equipment Data Heating System Cooling System i I . Thursdav June 7.Q 7nnn FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Beaches Habitat Spec 1214 Builder: Beaches Habitat Address: Permitting Office: City, State: Permit Number: Owner: Jurisdiction Number: j Climate Zone: North 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap: 100.0 kBtu/hr 3. Number of units,if multi-family 1 _ SEER: 10.00 _ 4. Number of Bedrooms 4 _ b.N/A - �. Is this a worst case? No 6. Conditioned floor area(ft2) 1214 ft2 c. N/A - 7. Glass area&type - a. Clear-single pane 0.0 ft2 _ 13. Heating systems b. Clear-double pane 150.0 ft2 _ a. Electric Heat Pump Cap: 100.0 kBtu/hr c. Tint/other SC/SHGC-single pane 0.0 ft2 HSPF:7.00 d. Tint/other SC/SHGC-double pane 0.0 ft2 b.N/A _ 8. Floortypes a. Slab-On-Grade Edge Insulation R=0.0, 149.0(p)ft - c. N/A - b. NIA c. NIA 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 50.0 gallons _ a. Frame,Wood,Exterior R=11.0,934.0 ft2 _ EF:0.92 - b. Frame,Wood,Adjacent R=11.0,64.0 ft2 - b.N/A _ c. NIA d. NIA _ c. Conservation credits _ e. NIA (HR-Heat recovery,Solar I 10. Ceiling types - DHP-Dedicated heat pump) a. Under Attic R=30.0, 1214.0 ft2 _ 15. HVAC credits b.NIA _ (CF-Ceiling fan,CV-Cross ventilation, c. NIA HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Interior Sup.R=6.0,25.0 ft _ RB-Attic radiant barrier, I b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.12 Total as-built points: 19283.00 PASS Total base points: 21411.00 1 hereby certify that the plans and specifications covered Review of the plans and by this calculation are in compliance with the Florida specifications covered by this yo. 0 Energy Code. calculation indicates compliance PREPARED BY: Ocean State HVAC with the Florida Energy Code. Before construction is completed DATE. this building will be inspected for 1 I hereby certify that this building, as designed, is in compliance with Section 553.908 X01)WE compliance with the Florida Energy Code. Florida Statutes. OWNER/AGENT: �� � 1A_ ILDING OFFICIAL: DATE: ! O DATE: EnergyGauge®(Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS. , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 1214.0 33.05 7223.1 Double,Clear N 1.5 6.0 15.0 19.22 0.94 270.6 Double, Clear W 1.5 6.0 15.0 36.99 0.91 506.7 Double, Clear N 1.5 6.0 30.0 19.22 0.94 541.2 Double, Clear E 1.5 6.0 30.0 40.22 0.91 1101.4 Double, Clear W 1.5 6.0 15.0 36.99 0.91 506.7 Double, Clear s 1.5 2.0 6.0 34.50 0.57 117.0 Double, Clear E 5.5 6.0 30.0 40.22 0.54 649.0 Double, Clear S 1.5 4.0 9.0 34.50 0.74 228.9 As-Built Total: 150.0 3921.6 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 64.0 0.7 44.8 Frame,Wood, Exterior 11.0 934.0 1.70 1587.8 Exterior 934.0 1.70 1587.8 Frame,Wood,Adjacent 11.0 64.0 0.70 44.8 Base Total: 998.0 1632.6 As-Built Total: 998.0 1632.8 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 6.10 231.8 Exterior 38.0 6.10 231.8 Base Total: 38.0 231.8 As-Built Total: 38.0 231.8 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1213.8 0.60 728.3 Under Attic 30.0 1214.0 0.60 728.4 Base Total: 1213.8 728.3 As-Built Total: 1214.0 728.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 149.0(p) -37.0 -5513.0 Slab-On-Grade Edge Insulation 0.0 149.0(p) -41.20 -6138.8 Raised 0.0 0.00 0.0 Base Total: -5513.0 As-Built Total: -6138.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1214.0 10.21 12394.9 1214.0 10.21 12394.9 EnergyGauge®DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT Summer Base Points: 16697.7 Summer As-Built Points: 12770.5 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 12770.5 1.000 0.974 0.341 1.000 4244.0 16697.7 0.3573 5966.1 12770.5 1.00 0.974 0.341 1.000 4244.0 EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 1214.0 9.76 2133.8 Double, Clear N 1.5 6.0 15.0 14.30 1.00 215.1 Double, Clear W 1.5 6.0 15.0 10.77 1.02 165.3 Double,Clear N 1.5 6.0 30.0 14.30 1.00 430.1 Double,Clear E 1.5 6.0 30.0 9.09 1.04 282.4 Double,Clear W 1.5 6.0 15.0 10.77 1.02 165.3 Double,Clear S 1.5 2.0 6.0 4.03 2.27 54.8 Double,Clear E 5.5 6.0 30.0 9.09 1.26 344.7 Double, Clear S 1.5 4.0 9.0 4.03 1.35 49.1 As-Built Total: 150.0 1706.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 64.0 3.6 230.4 Frame,Wood, Exterior 11.0 934.0 3.70 3455.8 Exterior 934.0 3.70 3455.8 Frame,Wood,Adjacent 11.0 64.0 3.60 230.4 Base Total: 998.0 3686.2 As-Built Total: 998.0 3686.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 12.30 467.4 Exterior 38.0 12.30 467.4 Base Total: 38.0 467.4 As-Built Total: 38.0 467.4 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1213.8 1.20 1456.6 Under Attic 30.0 1214.0 1.20 1456.8 Base Total: 1213.8 1456.6 As-Built Total: 1214.0 1456.8 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 149.0(p) 8.9 1326.1 Slab-On-Grade Edge Insulation 0.0 149.0(p) 18.80 2801.2 Raised 0.0 0.00 0.0 Base Total: 1326.1 As-Built Total: 2801.2 INFILTRATION Area X BWPM = Points Area X WPM = Points 1214.0 -0.59 -716.3 1214.0 -0.59 -716.3 EnergyGauge®DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: s BASE AS-BUILT Winter Base Points: 8353.8 Winter As-Built Points: 9402.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 9402.1 1.000 0.990 0.487 1.000 4532.2 8353.8 0.5340 4460.9 9402.1 1.00 0.990 0.487 1.000 4532.2 EnergyGaugeT"" DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: s BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2746.00 10984.0 50.0 0.92 4 1.00 2626.61 1.00 10506.4 As-Built Total: 10506.4 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 5966.1 4460.9 10984.0 21411.0 4244.0 4532.2 10506.4 19282.6 PASS �yo��HE * a r�GOD Wv EnergyGaugeT°^ DCA Form 60OA-97 EnergyGaugeWlaRES'97 FLRCNA-200 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows& Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area; .5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned s ace,tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on erimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer. Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGaugeT"' DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score,the more efficient the home. 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap: 100.0 kBtu/hr _ 3. Number of units,if multi-family 1 - SEER 10.00 - 4. Number of Bedrooms 4 - b.N/A - 5. Is this a worst case? No - - 6. Conditioned floor area(ft) 1214 ft2 c. N/A - 7. Glass area&type - - a. Clear-single pane 0.0 ft2 _ 13. Heating systems b. Clear-double pane 150.0 ft2 - a. Electric Heat Pump Cap: 100.0 kBtu/hr - c. Tint/other SC/SHGC-single pane 0.0 ft2 - HSPF:7.00 - d.Tint/other SC/SHGC-double pane 0.0 ft2 b. N/A 8. Floor types - - a. Slab-On-Grade Edge Insulation R=0.0, 149.0(p)ft ` c. N/A _ b. N/A - - c. N/A 14. Hot water systems 9. Wall types a. Electric Resistance Cap:50.0 gallons a. Frame,Wood,Exterior R=11.0,934.0 ft2 _ EF:0.92 _ b. Frame,Wood,Adjacent R=11.0,64.0 ft2 - b. N/A _ c. N/A - d. N/A - c. Conservation credits - e. N/A (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0, 1214.0 ft2 _ 15. HVAC credits _ b.N/A (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Interior Sup.R=6.0,25.0 ft RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) o�THE S7.4 in this home before final inspection. Otherwise,a new EPL Display Card will be completed p based on installed Code compliant features. Builder Signature: Date: - a Address of New Home: City/FL Zip: c01)we *1VOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating.Ifyour score is 80 orgreater(or 86for a USEPAIDOEEnergyStar7lfdesignation), your home may qualify for energy efficiency mortgage (EES incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 407/638-1492 or see the Energy Gauge web site at www.fsec.ucf edufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge®(Version:FLRCNA-200) 304814 MAP SHOWING SURVEY OF LOT 2, BLOCK 2, LEWIS SUBDIVISION, AS RECORDED IN PLAT BOOK 24, PAGE 92 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. O.vOL F Y 5 ��=oeMf,��.� �v.�,4 5J'•�EFT'� fo'A'icHr of-wwr 4'e#41#[/MK FEMIE TV L/NE �/i�[7�2•%Roi� � . FOUND%�"i�oN P/iE (4/0/A) -j$do.4o' uNK FcvcE-ter. Lorj Lor i vo BLOCK 2 VACANT BL oCK Z h Q ou��%2 vZoN pv,� WEST 50 00• \}FOUNQ%2 i�oi✓P/PE 6 CNA/N 1./NK FENCE 5. e rlV✓ /7 NOTES: 1) THIS IS A BOUNDARY SURVEY. 4) BEARINGS ARE BASED ON THE SOUTH 2) NO BUILDING RESTRICTION LINE, SHOWN ON PLAT, RIGHT-OF-WAY LINE OF DUDLEY THERE ARE RESTRICTION LINES BY ZONING AND STREET AS BEING DUE EAST BY PLAT. THERE MAY BE EASEMENTS THAT AFFECT THIS PROPERTY THAT ARE RECORDED IN THE PUBLIC RECORDS OF THIS COUNTY THAT-ARE NOT SHOWN ON THIS SURVEY. . 3) THIS PROPERTY LIES IN FLOOD ZONE "X" WHICH IS THE AREA DETERMINED TO BE OUTSIDE THE PREPARED FOR THE BENEFIT OF: 500 YEAR FLOOD ACCORDING TO FEMA FLOOD MAP REVISED 4/17/89, COMMUNITY PANEL N0. /���r�T���S�vM�/��TYO,c7,�/E�ACK.fON✓IEEE AN toning, GVMWiofoA *Rd O"r tool land dovebpeNnt rog iut do" not wwatute approvol for ow of pormta. Compliance a • Old aN Outer applicable bw. patrdding roquimmente must be OfB"ch t�ft so CNy of Adan; YuNding i t I F I Y I S R � P o !1 c 4 a _ 5 c E BUILDING, PLA NNINGAND ZONING INSPECTIONDe.P tRT:NE.VT CITY OFA TLANTIC BEACH, FLORIDA CER TIFIC4TE OF OCCUPANCY WORKSHEET Date Requested: Building Contractor: r' % � ¢ - ---- °uilding Permit Number: 02_- j ," PJ-.( 'address : Legal Description : Improvements to the above described property have been comcleted perm.- it accordance with the terms of the penit and is certified to be ready for occupancy as 9- � . Lowest Floor Elevation : required as built BEFORE ISSUING CERTIFICATE OF OCCUPANCY THE FOLLOWING MUST BE COMPLETE DE2ARTMENT DATE NOTIFIED DATE APPROVED BY Fire e--------- - Public Works � - 2 3' , a3 L�--�,��v� �ep , Planning �/,/-`?O' 03 Building