Permit 2136 Fairway Villas Ln CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FLORIDA 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 04-00028918 Date 8/25/04
Property Address . . . . . . 2136 S FAIRWAY VILLAS LN
Tenant nbr, name . . . . . . RENEW DRIVEWAY 03-26249
Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
- ---------------- ---- --- ------- -----------------
LOVE, MARY M. OWNER
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 35 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
- ---------------- ---------- ---------- ---------- ----------
Permit Fee Total 35 . 00 35 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 35 . 00 35 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING
C
C P
,.1
BUILDING OFFICIAL
CITY OF ATLANTIC BEACH
1 800 SEMINOLE ROAD
r' ATLANTIC BEACH, FLORIDA 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 03-00026249 Date 6/09/03
Property Address . . . . . . 2136 S FAIRWAY VILLAS LN
Tenant nbr, name . . . . . . DRIVEWAY EXTENSION
Application description RESIDENTIAL ADD/RENOVATE/ALTER
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 400
Owner Contractor
------------- ----------- ------------------------
MARY M. LOVE OWNER
2136 S FAIRWAY VILLAS LN
ATLANTIC BEACH FL 32233
(904) 241-2557
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc DRIVEWAY EXTENSION
Permit Fee . . . . 70 . 00 Plan Check Fee 35 . 00
Issue Date . . . . Valuation . . . . 400
Fee summary Charged Paid Credited Due
------ ----------- ---------- ---------- ---------- ----------
Permit Fee Total 70 . 00 70 . 00 . 00 . 00
Plan Check Total 35 . 00 35 . 00 . 00 . 00
Grand Total 105 . 00 105 . 00 . 00 . 00
BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED
UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN
RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS
WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
t
BUILDING OFFICIAL
OF
�t!y�i1 juju. CITY
I 8 O EMIT NO E ROAD CH
ATLANTIC BEACH,FLORIDA 32233-5445
TELEPHONE: (904)247-5800
FAX: 904 247-5805
SUNCOM) 852-5800
t41 ' http://ci.atlantic-beach.fl.us
PLAN REVIEW COMMENTS
Permit Application # 03
Applicant: L4—
Address: J - Fa L,
Project:
our application is approved
o Your permit application has been reviewed and the ioilowing items need
attention:
Please re-submit your application when these items have been completed.
Reviewed by
Signedj 4 Date QG -Of
Contractor Notified Date
K CITY OF ATLANTIC BEACH
r r3 '4 BUILDING PERMIT APPLICATION
(ALTERATIONS/ADDITIONS)
Date:6—un '
Job Addres ),A
Owner of Property: rn
L&Aj TC'Yti�
Address:p� ,tl Telephone: a I//-�
Legal Description: Block Number: Lot Number: (_/ Zoning District:
Contractor: — State License Number:
Contractor's Ad ess: �
Telephone: Fax:
De crib,e proposed use and work to be done: .i'd
Present use of land or building(s): &.62-11da-al
Valuation of proposed construction:
What are the dimensions of the added space:_� feet xfeet
Will the added area be heated and cooled? New electrical or increase in service?
New plumbing fixtures? _ New.fireplace? New heating/air conditioning?
Is approval of Homeowner's Association or other private entity required?/to If yes,please submit with this application.
Will t is project involve changes in elevation,site grade or any use of fill material or the removal of any trees?
NO. Applicant certifies that no change in site grade or fill material will be used on this project.
YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building
Permit.
NO. Applicant certifies that no trees will be removed for this project.
YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree
Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month.
Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate.
Incomplete applications may result in delay in issuance of permit.
STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please
cgntact-xl►e.-Planning-and Znflmg pattmeiit df-904=2426. In order to correctly verify zoning designation, please have
ser's Real Estate Number available.
STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction
topographical survey or grading plan is required. (If not required, written verification must be provided with this application.)
The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834
STEP 3. Submit Tree Removal Application if trees are to be removed or relocated.
STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if
owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic
Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826
800 Seminole Road •Atlantic Beach,Florida 32233-5445
Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atiantic-beach.fl.us
Page 1 Revised 1/14/03
In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being
performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner.
1. Current survey showing the property boundary with bearings and distances and the legal description.
2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify
any existing structures and uses.
3. If required by the Department of Public Works,a pre-construction topographical survey.
4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies.
5. Impervious Surface area calculations: include driveways, sidewalks, patios and other Impervious Surfaces. Swimming pools
may be excluded from total Impervious Surface.
6. Other information as may be appropriate for individual applications.
I hereby certify that all information provided with this application is correct.
Signature of owner: ' (rte ` Date:
I hereby certify that I have read Zd examined this application and know the same to be true and correct. All provisions of the laws and
ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to
give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the
governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the
above information being true and correct and that the plans and supporting data have been or shall be provided as required.
Signature of Contractor: --- Date: �0_3
Address and contact informatioo)n/fof persontoreceive all correspondence regarding this application(please print).
Name: / / t h-C-,'V
Mailing Address: 2 W N
Telephone: C � Fax: E-Mail:
AS TO OWNER:
Sworn to and subscribed before me this day of 200 3.
State of Florida,County of Duval
tWX 7eanne R.Castro
+? MY COMMISSION# CC907357 EXPIRES
February 19,2004 Notary's Signature:
pT ad°` BONDED THRU TROY FAIN INSURANCR,INC
Personally known
Produced identification
Type of identification produced 'O
AS TO CONTRACTOR:
Sworn to and subscribed before me this day of , 20
State of Florida,County of Duval
Notary's Signature:
❑ Personally known
❑ Produced identification
Type of identification produced
800 Seminole Road •Atlantic Beach,Florida 32233-5445
Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us
Page 2 Revised 1/14/03
CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS
DATE PERMIT NO.
ISSUED BY THE CITY
JOB ADDRESS f/ VALUATION $
PERMI7TEE ON oft�
PERMITTEE ADD TELEPHgNE NO.
REQUESTING PERMISSION FROM THE CITY OF�7r-ATTLA (II`C�BEACH TO CONSTRUCT
��Y 4��/ �/�/z92J r r J LOlff .s/ f 4A fff
LOCATIONS: (REFERENCE TO CROSS-STREET)
I . APPLICANT DECLARES THAT PRIOR TO FILING THIS APPLICATION HE HAS ASCERTAINED THE LOCATION OF ALL
EXISTING UTILITIES, BOTH AERIAL AND UNDERGROUND AND THE ACCURATE LOCATIONS ARE SHOWN ON THE
SKETCHES.
FF/ A LETTER OF NOTIFICATION WAS MAILED TO THE FOLLOWING UTILITIES/MUNICIPALITIES:
JACKSONVILLE ELECTRIC AUTHORITY YES Y< NO ( ) DATE: -
YYYYYY������R� BELL SOUTH TELEPHONE COMPANY YES P<) NO ( ) DATE:
FERRELL GAS YES (�C) NO ( ) DATE:
MEDIA ONE CABLE TV YES ) NO ( ) DATE:
2. WHENEVER NECESSARY FOR THE CONSTRUCTION, REPAIR, IMPROVEMENT, MAINTENANCE, SAFE AND EFFICIENT
OPERATION, ALTERATION OR RELOCATION OF ALL, OR ANY PORTION OF SAID STREET OR EASEMENT AS
DETERMINED BY THE DIRECTOR OF PUBLIC WORKS, ANY OR ALL OF SAID POLES, WIRES, PIPES, CABLES OR
OTHER FACILITIES AND APPURTENANCES AUTHORIZED HEREUNDER, SHALL BE IMMEDIATELY REMOVED FROM
SAID STREET OR EASEMENT OR RESET OR RELOCATED HEREON AS REOUIRED BY THE DIRECTOR OF PUBLIC
WORKS, AND AT THE EXPENSE OF THE PERMITTEE UNLESS REIMBURSEMENT IS AUTHORIZED.
3. ALL WORK SHALL MEET CITY OF ATLANTIC BEACH OR FLORIDA DEPARTMENTF A SPI RATION STANDARDS
AND BE PERFORMED UNDER THE SUPERVISION OF ////yl/ 0 (CONTRACTOR'S
PROJECT SUPERINTENDENT) LOCATED AT TELEPHONE NO.
4. ALL MATERIALS AND EOUIPMENT SHALL BE SUBJECT TO INSPECTION BY THE DIRECTOR OF PUBLIC WORKS OR
HIS DESIGNEE.
S. - ALL CITY PROPERTY SHALL BE RESTORED TO ITS ORIGINAL CONDITION AS FAR AS PRACTICAL, IN KEEPING WITH
CITY SPECIFICATIONS AND THE MANNER SATISFACTORY TO THE CITY.
6. A SKETCH OR PLANS COVERING DETAILS OF THIS INSTALLATION SHALL BE MADE A PARTOFTHIS PERMIT.
7. THIS PERMITTEE SHALL COMMENCE ACTUAL CONSTRUCTION IN OOD
FAITH WITHIO (0 DAYS FROM THE DAY
OF SAID PERMIT APPROVAL AND SHALL BE COMPLETED WITHIN r„( '1 DAYS. IF THE BEGINNING DATE IS
MORE THAN 60 DAYS FROM DATE OF PERMIT APPROVAL, THEN PERMITTEE MUST REVIEW THE PERMIT WITH THE
DIRECTOR OF PUBLIC WORKS TO MAKE SURE NO CHANGES HAVE OCCURRED IN THE AREA THAT WOULD
AFFECT THE PERMITTED CONSTRUCTION.
S. IT IS UNDERSTOOD AND AGREED THAT THE RIGHTS AND PRIVILEGES HEREIN SET OUT ARE GRANTED ONLY TO
THE EXTENT OF THE CITY'S RIGHT, TITLE AND INTEREST IN THE LAND TO BE ENTERED UPON AND USED BY THE
HOLDER, AND THE HOLDER WILL, AT ALL TIMES, ASSUME ALL RISK OF AND INDEMNIFY, DEFEND, AND SAVE
HARMLESS THE CITY OF ATLANTIC BEACH FROM AND AGAINST ANY AND ALL LOSS, DAMAGE, AND COST OF
EXPENSES ARISING IN ANY MANNER OF THE EXERCISE OR ATTEMPTED EXERCISES BY THE HOLDER OF THE
AFORESAID RIGHTS AND PRIVILEGES.
9, THE DIRECTOR OF PUBLIC WORKS SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS PRIOR TO STARTING WORK
AND AGAIN IMMEDIATELY UPON CMPLETION.
SUBMITTED BY: ??, /�L (PLACE CORPORATE SEAL IF APPLICABLE)
SWORN TO AND SUBSCRIBED BEFORE ME THIS DAY OF IyQ
NOTAFff PUBLIC
00
Jeanne R.Castro
*: *: MY COMMISSION# CC907357 EXPIRES
'•. February 19,1004
60NDED THRU TROY FAIN INRURAW9,INC
` RE E i
1,_,
i
MAP SHOWING BOUNDARY SURVEY i'OF .JUN Q 6 2003
LOT 10, FAIRWAY VILLAS, AS RECORDED IN PLAT BOOK 39, PAGE 22
OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLOI
IDA.
CERTIFIED TO: S
MARY M. LOVE
FIRST UNION MORTGAGE CORP ` �"T- _...V._ -
CRABTREE AND FALLAR, P.A.
STEWART TITLE GUARANTY COMPANY MAYPORT ROAD
FOUND N 01'23'15" W 70.00' ( AT) rei Leers
STAMPED ACM Re 8ioz• D N 01'21 X19" W 69.98 ME RED Dom' NO
FbDN QENTT1�J n
— -V-- ❑ ❑ — ❑ ---X-- ❑
4.8' COLUMNS( � .3' ~ 1"al land
12• EVES bd wnwms
MNCOAao l ft. conoonoa
SHED
_ I «tea wa
o waucar N
. M �t N ar
40' LANDSCAPE BUFFER AR
Lor 10 "POW op
9 `� a D_
W`-'
Ld
QxLLJ DECK o
ov o toO
"• c�y (! 19.8'
Oi In 4.2' COVERED °i 13.2'
LOT 11 x w LOT 9
W 20
_W
x
33 � ONE STORY + o uo 0D
2z
FRAM
3 3 11.7 POSTED #E2136 g Z Z f t�f05
In
`t
.�, Co co x -�
X —
. M
N•..... 1.D' .wi/
00 60 C4
19.8'/L x
��
1.T 123
rhe '
FOUND 1/2'IRON PIPE
STAMPED 'L9 3358•
2 1R
,-7.5*AU KS
EASEMENT
�,�5� �j3 Fd�p�S,fig 42�PSVFtE.
" r- etl -5^7
FOUND 1/2' IRON PIPE FOUND X CUT rf .46A5• r Cj`` E
CAP DESTROYED POINT OF TANGENCY c A-3-t_5 SVRED� \ -7
oaf S 01'20'22" E 47-0 CMORD S .A6
14.23 (MEASURED) BCH 0,q.5� E X5.`0-\
I S 01'2340 E S 133 PLP.T)
f
14.22' (PLAT) 42•(cW Y VILLA LAN SOUTH
FAIR A1 (50.0' RIGHT OF WAY)
LEGEND:
R = RADIUS —x— — FENCE NOTES: ACCEPTED 9Y:
L = LENGTH O = CONCRETE
NOTES: REVISI ONS
PLAT OVADIMr_ nc N 86'36'45" W Ai nuc Tic
CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS
DATE-� / PERMIT NO.
/ ISSUED BY THE Cl / /7/p
JOB ADDRESS VALUATION v'w
PERMITTEE 11n ll—�lflo ON L
PERIAMEE ADD TELEPHONE NO. —
REouESTING PERMISSION FROM THE CITY OF ATLA IC BEACH TO CONSTRUCT o7�f�.A'j7l� _ d^
'7 AZzal 7�dJ2i' ISD 22ezha-"
LOCATIONS: (REFERENCE TO CROSS-STREET)
I . APPLICANT DECLARES THAT PRIOR TO FILING THIS APPLICATION HE HAS ASCERTAINED THE LOCATION OF ALL
EXISTING UTILITIES, BOTH AERIAL AND UNDERGROUND AND THE ACCURATE LOCATIONS ARE SHOWN ON THE
SKETCHES.
A LETTER OF NOTIFICATION WAS MAILED TO THE FOLLOWING UTILITIES/MUNICIPALITIES:
JACKSONVILLE ELECTRIC AUTHORITY YES �< NO ( ) DATE:
F/ BELL SOUTH TELEPHONE COMPANY YES P<) NO ( ) DATE:
FERRELL GAS YES NO ( ) DATE:
MEDIA ONE CABLE TV YES ) NO ( ) DATE:
P. WHENEVER NECESSARY FOR THE CONSTRUCTION, REPAIR, IMPROVEMENT, MAINTENANCE, SAFE AND EFFICIENT
OPERATION, ALTERATION OR RELOCATION OF ALL, OR ANY PORTION OF SAID STREET OR EASEMENT AS
DETERMINED BY THE DIRECTOR OF PUBLIC WORKS, ANY OR ALL OF SAID POLES, WIRES, PIPES, CABLES OR
OTHER FACILITIES AND APPURTENANCES AUTHORIZED HEREUNDER, SHALL BE IMMEDIATELY REMOVED FROM
SAID STREET OR EASEMENT OR RESET OR RELOCATED HEREON AS REOUIRED BY THE DIRECTOR OF PUBLIC
WORKS, AND AT THE EXPENSE OF THE PERMITTEE UNLESS REIMBURSEMENT IS AUTHORIZED.
v
3. ALL WORK SHALL MEET CITY OF ATLANTIC BEACH OR FLORIDADEPARTMENTF A SPIRATION STANDARDS
AND BE PERFORMED UNDER THE SUPERVISION OF �'�/ � c LS%� (CONTRACTOR'S
PROJECT SUPERINTENDENT) LOCATED AT EEE TELEPHONE NO.
4. ALL MATERIALS AND EQUIPMENT SHALL BE SUBJECT TO INSPECTION BY THE DIRECTOR OF PUBLIC WORKS OR
HIS DESIGNEE.
5. ALL CITY PROPERTY SHALL BE RESTORED TO ITS ORIGINAL CONDITION AS FAR AS PRACTICAL, IN KEEPING WITH
CITY SPECIFICATIONS AND THE MANNER SATISFACTORY TO THE CITY.
6. A SKETCH OR PLANS COVERING DETAILS OF THIS INSTALLATION SHALL BE MADE A PART OF THIS PERMIT.
7. THIS PERMITTEE SHALL COMMENCE ACTUAL CONSTRUCTION IN OOD FAITH WITHIQ(0 DAYS FROM THE DAY
OF SAID PERMIT APPROVAL AND SHALL BE COMPLETED WITHIN 6� DAYS. IF THE BEGINNING DATE IS
MORE THAN 60 DAYS FROM DATE OF PERMIT APPROVAL, THEN PERMITTEE MUST REVIEW THE PERMIT WITH THE
DIRECTOR OF PUBLIC WORKS TO MAKE SURE NO CHANGES HAVE OCCURRED IN THE AREA THAT WOULD
AFFECT THE PERMITTED CONSTRUCTION.
8. IT IS UNDERSTOOD AND AGREED THAT THE RIGHTS AND PRIVILEGES HEREIN SET OUT ARE GRAN'T'ED ONLY TO
THE EXTENT OF THE CITY'S RIGHT, TITLE AND INTEREST IN THE LAND TO BE ENTERED UPON AND USED BY THE
HOLDER, AND THE HOLDER WILL, AT ALL TIMES, ASSUME ALL RISK OF AND INDEMNIFY, DEFEND, AND SAVE
HARMLESS THE CITY OF ATLANTIC BEACH FROM AND AGAINST ANY AND ALL LOSS, DAMAGE, AND COST OF
EXPENSES ARISING IN ANY MANNER OF THE EXERCISE OR ATTEMPTED EXERCISES BY THE HOLDER OF THE
AFORESAID RIGHTS AND PRIVILEGES.
9. THE DIRECTOR OF PUBLIC WORKS SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS PRIOR TO STARTING WORK
AND AGAIN IMMEDIATELY UPON MPLETION,
SUBMITTED BY: S (PLACE CORPORATE SEAL IF APPLICABLE)
SWORN TO AND SUBSCRIBED BEFORE ME THIS DAY OF iyQ
NOTA PUBLIC
Jeanne R.Castro
MY COMMISSION# CC907357 EXPIRES
r: o`s February 19,2004
tioNOEUTMRUTROY FAIN IN}jUYAN6E,INC
t , CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
J
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
INSPECTION EMAIL REQUEST:
Building-dept(a gab.us
Application Number . . . . . 07-00000806 Date 6/13/07
Property Address . . . . . . 2136 FAIRWAY VILLAS LN
Application type description MECHANICAL ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
COLSTEN AIR CREATIONS HEATING AND
COOLING INC
ATLANTIC BEACH FL 32233 4224 MARIANNA RD
JACKSONVILLE FL 32217
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . .
Permit Fee . . . . 59 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/10/07
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- -7--------
Permit Fee Total 59 . 00 59 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 59 . 00 59 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
Jun 11 07 02,30p The Navarro's 2983120 p,3
CITY OF ATLANTIC BEACH
MECHANICAL PERMIT APPLICATION
Date:
Property Address: oL 13 G fa t on Wa
V d A.S 1.0 a(0
Owner �' o/S ort Telephone 0:jDN-;[!!1 5 2
Contractor..A dreatt; ' - cTelephone#: 90y-"d-u q 24
Contractor Address: Fax#: jd
Contractor Signature: a ,
In consideration of p=it given do' work as dcKdbed in the above statement,we hereby agree to perform said work in accordance
with the attached plans and speei for w hieh are a part hereof aad in accordance with the City of Atlantic Beach ordinances and stand"of
good tor.-tirx listed therein.
Type of Heating Diel: If other construction is being done on this building
2P Electric or site,list the building permit number:
❑ Cas: LP Natural _Central Utility
❑ Oil
0 Other—S c'
MECRANICAL EQUIPMENT TO BE]INSTALLED NATURE OF WORK
❑ Heat Space _Recessed Central _Floor d Residential
AP Air Conditioning: ,Room ✓Central
❑ Duct System: katWml Thickness ❑ Commercial
Maximum capacity cftn
11 Refrigeration ❑ New Building
❑ Cooling Tower, Capacity tam Q/ Existing Building
❑ Fire Sprinklers:Number of Heads
❑ Elevator. Manlifl Escalator (Number) 6/ Replacement of Existing System
o Gasoline Pumps (Number)
❑ Tanks (Number) ❑ New Installation
❑ LPG Containers (No system previously installed)
❑ Unfired Pressure Vessel ❑ Extension or Add-on to Existing System
❑ Boilers
❑ Gas Piping 0 Other-Specify
❑ Other—Specify
LIST ALL EQUIPMENT
AIR CONDITIONING,REFRIGERATION EQUInU NT&CONDENSOR'S Approving
Number Units Description Model 4 Man liketrer Tin's Agency
t l 1 /
HEATING—FURNACES.BOILERS.FIREPLACES$AIR HANDLER'S Approving
Number Units Description Model# Manufacnua BTU's Agency;
TANKS Nominal Capacity Type Liquid serial Approving
HM b do almensions Contained anufacnrrer No. Axencv
800 Seminole Road a Atlantic Beach,Florida 32233.5443
Fhona(904)247-SM• Fax: (904)247-SM a httn•j tjptic-b*Wh.il.os Revised 1/04
r,.
CITY OF ATLANTIC BEACH
MECHANICAL PERMIT APPLICATION
X.:
Date:
Property Address: Ce i t uz,a 4 I i I a S P
Owner: 0"'m a r- t5 f o r1 Telephone#•
Contractor:Air .reefJG„s lleatiN s I N&%`r-Telephone#: `ldy-63 G-G 3 7
Contractor Address: L Fax#: SA»7,—, a5 G 461te
Contractor Signature: I JA '
In consideration of permit given for doi a work as described in the above statement,we hereby agree to perform said work in accordance
with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinances and standards of
good practice listed therein.
Type of Heating Fuel: If other construction is being done on this building
or site,list the building permit number:
0P Electric
❑ Gas: _LP Natural _Central Utility
❑ oil
❑ Other—Specify
MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK
❑ Heat _Space _Recessed Central _Floor 1/ Residential
JW Air Conditioning: Room ✓Central
❑ Duct System: Material Thickness ❑ Commercial
Maximum capacity cfm
❑ Refrigeration ❑ New Building
❑ Cooling Tower: Capacity gpm W/ Existing Building
❑ Fire Sprinklers:Number of Heads
❑ Elevator: __ Manlift Escalator (Number) QY Replacement of Existing System
❑ Gasoline Pumps (Number)
❑ Tanks (Number) ❑ New Installation
❑ LPG Containers (Number) (No system previously installed)
❑ Unfired Pressure Vessel ❑ Extension or Add-on to Existing System
❑ Boilers
❑ Gas Piping ❑ Other-Specify
❑ Other—Specify
LIST ALL EQUIPMENT
AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving
Number Units Description Model# Manufacturer Ton's Agency
A N 0,41ml A an I
HEATING—FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving
Number Units Description Model# Manufacturer BTU's Agency
TANKS Nominal Capacity Type Liquid Serial Approving
How Many &Dimensions Contained Manufacturer No. Agency
800 Seminole Road•Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800• Fax: (904)247-5845• http://www.ei.atiantic-beach.fl.us Revised 1/04
FAIRWAY VILLAS
STOKES _ & COMPANY
C� BUILDERS & LAND DEVELOPERS
�70.GYJ I
4 i
I . • I`Ls�iP��CA
12'
l
i
i
DEPARTMENT OF BUILDING
CITY OF ATLANTIC BEACH,FLORIDA PERMIT NO. ®O
PERMIT TO BUILD
THIS PERMIT MUST BE POSTED ON JOB
j
Date Tutt 3 19 24 a
i
Valuations 45f 925.2G Fee$ 1 89. 75
it i 4>di Fy
This permit not valid until above fee has been paid to City Treasurer,and is
subject to revocation for violation of applicable provisions of law.
This is to certify that STOKES & COMPANY
4319 Salisbury Road
has permission to build Singill I andly 11ome as per plans
i I
i
Classification Zone Dl-,n} 1
Owned by SBokes & Company
Lot 10 Block 'Pa i rU.7a)7 1,11_ j
House No. 2136 Fairway Villas l antz t:413:1r14
According to approved plans which are part of this permit
NOTICE—ALL CONCRETE FORMS
AND FOOTINGS MUST BE IN-
SPECTED BEFORE POURING.
PERMIT VOID SIX MONTHS
AFTER DATE OF ISSUE
/ � �---- --► 0 Building material,rubbish and debris
Zi from this work must not be placed
in public space, and must be cleared
up,.and.tauled away by either
rtracto owner. g
° Building Official.
I
FOR OFFICE PERMIT DATE 1 CONTRACTOR
USE ONLY NUMBER
PLUMBING
ELECTRICAL
i
SEWER
WATER
I i
PLUMBING WORKSHEET
/ SINKS L SBO14ERS DISHWASHERS
CLOSETS BATH TUBS FLOOR DRAINS
WASHING MACHINE � WATER HEATERS DISPOSALS
LAVATORY URINALS OTHER
TOTAL FIXTURE COUNT I
FIXTURE UNIT BREAKDONN
FIXTURE UNITS ARE ESTABLISHED AS THE MEASURFJJENNT OF WATER DEI.IAND FOR EACH WATER FIXTURE
UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. 'THE WATER SUPPLY CHARGE IS HEREBY
FIND AT $10. 00 PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM.
BATHROOM. GROUP CONSISTING OF LAVATORY (1 UNIT)
WATER CLOSET, LAVATORY, AND
BATH TUB OR SHOWER STALL SERVICE SINTK TRAP STAND
(6 UNITS) (3 UNITS)
DRINKING FOUNTAIN (�5 UNIT) URINAL, WALL LIP
(4 UNITS)
FLOOR DRAIN (1 UNIT)
WASHING MACHINE RES.
URINAL, PEDESTAL, SYPHON (3 UNITS)
JET BLOWOUT (8 UNITS)
WATER CLOSETS, VALVE OPERATED
WATER CLOSETS, TANK-OPERATED (8 UNITS)
(4UNITS)
SHOWER STALL, DOMESTIC
BATHTUB (W./OR W/O OVERHEAD (2 UNITS)
SHOWER) (2UNITS)
LAUNDRY TRAY
BIDGET (3 UNITS) (2 UNITS)
DI SI ?.'rSHER (2 UNITS) KITCHEN SINK (2 UNITS)
KITCHEN SINKA ASTE GRINDER
(3 UNITS)
TOTAL FIXTURE UMTS @ $10-.00 EACH- c/Pao m2zqe•oo
DEPARTMENT OF BUILDING T ) i
CITY OF ATLANTIC BEACH,FLORIDA PER1�l�'� NO. � � � ra
PERMIT TO BUILD
THIS PERMIT MUST BE POSTED ON JOB ,
Date July 3, 19 84
Valuation$�LUMBuN_ Fee$
4". y
This permit not valid until above fee has been paid to City Treasurer,and is
subject to revocation for violation of applicable provisions of law.
This is to certify that R&C, PTITIMF5 ATO
i
has permission to bVjW— 1—NNS-TALL PL144-219122
Classification RF,S T DENT TAT. T
Zone PLD
Owned by sTnXES & COMPANy
Lot 10 Block SID
i
House No. 2136 Fairway Villas Lane SOt th
According to approved plans which are part of this permit
NOTICE—ALL CONCRETE FORMS
AND FOOTINGS MUST BE IN-
SPECTED BEFORE POURING. IN
PERMIT VOID SIX MONTHS
„ AFTER DATE OF ISSUE
4 01 'r---C 0 Building material, rubbish and debris
ii from this work must not be placed
in public space, and must be cleared
A up..and-h<auled away by either con-
CITY OF ATLANTIC BEACH
APPLICATION FOR PLUMBING PERMIT
f /�
OWNER'S NAME // � � `
LOCATION
MASTER PLUMBER .i
STATE/COUNTY OCCUPATIONAL LICENSE N0.
CERTIFICATE NO.
CONTRACTOR
TYPE OF BUILDING
SINKS SHOWERS
.Z LAVATORY / WATER HEATERS
BATH TUBS j DISHWASHERS
URINALS / DISPOSALS
CLOSETS _J_WASHING MACHINE
FLOOR DRAINS ) J OTHER
// TOTAL FIXTURE COUNT
INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH.THE MOST RECENT
EDITION OF THE SOUTHERN STANDARD PLUMBING CODE.
I
DEPARTMENT OF BUILDING ^O O
CITY OF ATLANTIC BEACH,FLORIDA PERMIT NO.- o
PERMIT TO BUILD
THIS PERMIT MUST BE POSTED ON JOB
Date July 3, 19 13
Valuation$ MPCHANICA1, Fee$ 3k C):)
This permit not valid until above fee has been paid to City Treasurer,and is
subject to revocation for violation of applicable provisions of law.
This is to certify that WILLIAMS & SONS HEAT & AIR CONN TT03.TZT 3
has permission to l�rilrls, T 17c� ,Trj � � ru �Orlj�=OSNG
Classification RESIDENTIAL Zone_PJJL)
Owned by STOKE; K COMPANY �
Lot 0 Block S/D
House No. 2] 36 Fairwya Villas Lane South
According to approved plans which are part of this permit
NOTICE—ALL CONCRETE FORMS
AND FOOTINGS MUST BE IN-
SPECTED BEFORE POURING.
PERMIT VOID SIX MONTHS
AFTER DATE OF ISSUE
��—� �----� O Building material, rubbish and debris
I from this work must not be placed
in public space, and must be cleared
up...anc! auled away by either con-
�•tract r,Jowner,
r
Building Official.
FOR OFFICE PERMIT
USE ONLY NUMBER DATE CONTRACTOR it
I
PLUMBING
ELECTRICAL
SEWER
WATER
At? +AMA,
WII_I)ING AND Z 01 ,'MG INNI C,"I'f )I-4 UIVi4ION
CYIY OF ATIA'0IC PFACH, 11PRIDA
APPLICATION FOR MrCI-lANICAL I'LERMIT
— IF P0;tT.ANT---/4VGoenf to comp!&}• all ifomt in std >ns 1. 11. 111, end IV. ^_
S:de of_ LIL L 1 a�1--»J_. l+.t. oe---�--- --- Sf. •ad_._. s1.
LOCATION (t:eMb!rvlh, c _/�.lert.Wert) A4dross 11 Shoehl
OF 1 ` ,
r IJILms
(Stele porlkA of lad if Iva t#ea M tot-Afteck 6gbI do"tip600 per dwd ie dY scats it Mcwoy)
11. TWE OF kP0,'OSE0 M-EC!-4:.41CAL WOPX — All •ppliunh tornpkla Perft A — D —
A. US: Of WILDING E. QWI:FASNIP
RESIDENTIAL IS. (9,/Pti„efe (indFrid.el,Crv,oKCtAI,
1. ( Oho f0m;Iv 11. 0 ut'lity ir»fitrrtiy.,oft.)
11. Q posr.R IWen.l, $tets N"I yoxon..wwl)
1. ❑ Tera er w.or. !.rent/— M 113Sc%", fit Kry,
Eo se .WMLar of poo ms._......_.r lAbs "col:onal C. NATUI;E Of WORK
I. ❑ Tr.nr:enl, bol, r-tol, 17. V New sw7d;no
rwn:nf l.ovre — 11. ❑ S+o-e, rooma rtlole
Enloe rYml.er of vnih ._._ Otiw IR. Q Ea'rlino Sri'diM.
R. ❑ Other ros4salie) __ _— t4. ❑ OTrEtt.spECIr1l If. Q of arir601'10fem
70. a NN inrfeCafioa (fie errlewl yr,Yiprrfy MsMMod)
WON.RESIDENTIAL
— 21. Q 6tsn►ion or widen N•tirtiev ey:}onr•
f. ❑
72. ❑ OlkW—Srocify
.. Q Chvlmh, athor roll fiovt
T. ❑ IndY►Itiel — t
�. Q Gereyc caprice elafiea
�. ❑ HOlpital. inrlilvl;aryl
E Type, Cf :uILD1114
10. ❑ OfGce. Lent, profatr:onsl IL ❑ Nwenber of rtornL—___.___...�
_.._�.-- ----- — ----- 17. ❑ Wcod forme
0. MECHANICAL FQUIFMENT TO tE INSTAUAD
11. ❑ I.lawn-y and.-.od
(Pro•:da camp'ale 141 of compan•ntr On L.rcl of Wo f,-ml 31. ❑ Re:ntartrl concrete
11. (jr' Fianace: ❑ Speco ❑ Rocosto/ W Control O finer
40. 0 SlrvctYral deet
N. Q"Air Condilioninv: ❑ toom ar Conlrel
Q ,
7S. Is!( Dvc1 Srrlo, matepial �L►� f rcA �n:d.� +• sl• ❑ OMor
'1'Ui\AGC t
M ❑ 16f1:;.1.lie0
M ❑ Cool:nv to-or- Cap.ci5v — v.par.
THIS SPACE POR ofNp YSE ONLY
(�wd)
7R. ❑ At* rpnnNon• Nvmbav of ho-.de 1
79. Q Elo.tlor ❑ tre-.'iU Q
I0. ❑ Gt:.aline Irnnfft-- — (wvrn'.er)
• i
It"dfig
11. Q UV
11. (� Unfired prerlYn .rust _`
Permit App•crod by Data_
14. ❑ blare 4
IS. Q Oth-f — spxily _ perrmil F..
III. GEN'--RAL I141FORMATION
A. Tr;.. c/L.eti•q mol: e•
IS OTPER CCNLTRVCTICN ICING 0.0Nc 0%
�Z. (� E'a:frit THIS IIJIl01N0 on SITR i
CITY OF ATLANTIC BEACH
FLORIDA
APPLICATION FOR BUILDING PERMIT
DATE �f t �--1 19
Owner ra IL ,c C16 Address 4'31 ,.t; ; �, Telephone ') 37- S3 L1
Architect Pe,-c z S v o,, Z. .. 0. o c. Address 41 D$0, 1 ,� Telephone -Z 3 7- `t 5 o ti
Contractor S to k a C,a n,p�.,•,, Address L431c, S A Q;g b�,y fZdt Telephone 23 7. 15 3 y
License Number }t C A 2 3 p 4 p Expiration Date g S
LOT # 1 b BLOCK # r a. Subdivision Zone
Street ,4%3(. Fa; v; 1 L r' S Between F a:1, L"J g=j 0'. cti 5 �,& y1h ,} �Side
Valuation 1-5--l-AT oO o Purpose of Building s�„.j c J&.,, j Const. r
Dimensions-Bld(j �k a,.-) Dimensions-Lot r,,e r S 1 t z Size Foot. %L, x Z o
SZ.Piers — SZ.Sills - Greatest Sill span ft. --
Heating St,,; n 1 c c,.�t ,.o•� Solid or Filled Ground S 1, i 11 Roof t r S S
SZ.Ceiling Joists ',� x y Distance on Centers 2` Greatest span —
SZ.Floor Joists Distance on Centers Greatest span
SZ.Rafters C� X y Distance on Centers � Greatest span
Two copies of plans and specification shall be submitted with application.
Inspections required:
1. When steel is in place and ready to pour footing.
2. When steel is in place and ready to pour columns and/or lintels.
3. When steel is in place and ready to pour beam.
4. When framing is completed.
5. When rought plumbing is completed and ready to cover up.
6. When septic tank drain field or sewer is laid but before covered.
7. Electrical inspection. SET BACKS
8. Final inspection.
In case of any rejection, reinspection MUST be Rear lot line
called for after corrections are made.
M
In consideration of permit given for doing
the woek as described in the above statement,
we hereby agree to perform said work in accord- o �'
ance with the attached plans and specifications,
which are a part hereof, and in accordance with
the building regulations of the City of Atlantic
m
Beach.
r1 O F %R. L P►- A c ei, Frt. lot line
Signature OWNER Address q 3t q a.�;�b rY J2 3221 V
Signature BUILD Address 31 °i ►S 6 ti 311 i V
CITY OF ATLANTIC BEACH, FLORIDA
A roved ION FOR ELECTRICAL, PERMIT
p Y APPLICAT
t-f
TO THE CHIEF ELECTRICAL INSPECTOR: DATE: '/ ' 19
IMPORTANT NOTICE:
t
IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE
HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS,
WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF
ATLANTIC BEACH ORDINANCES. 1
ELECTRICAL FIRM: MASTER ELECTRICIAN SIGNATURE JOUBNEXMAN
NAME ADDRESS: z� Q' FD _ BOXl&t l Q
put_n�l �� (D 00-7
BLDG.SIZE BETWEEN:
i
RES.( I APT.( 1 comm.11 1 PUBLIC( 1 INDUS.1 1 NEW( 1 OLD( ) . REW.( 1
ADDITION ( ► TRAILER ( ► TEMP. ( 1 SIGNS ( I SQ.FT.
SERVICE: NEW( 1 INCREASE ( REPAIR ( 1 FEE
CONDUCTOR SIZE AMPS COPPER ALUM.
SWITCH OR BREAKER AMPS PH W c OlT RACEWAY
EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY
FEEDERS NO. SIZE NO. SIZE NO. SIZE
LIGHTING OUTLETS CONCEALED OPEN TOTAL
l
RECEPTACLES CONCEALED OPEN TOTAL
0.90 AMPS. 91.100 AMPS.
SWITCHES «
INCANDESCENT
FLUORESCENT&M.V.
FIXED 0.100 AMPS. OVER
APPLIANCES BELL TRANSF.
AIR H.P. RATING H.P. RATING
CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT
i
0.1 OVER
MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS
4
MISCELLANEOUS
i
rn Adl(-C^n%AtOQ. a@Llr%cn cnn v
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
SECTION 9—RESIDENTIAL POINT SYSTEM METHOD CLIMATE ZONES
FORM 900-A-84 DEPARTMENT OF COMMUNITY AFFAIRS NORTH 1 2 3
his form may be used to demonstrate compliance with the Energy Code for new single-family detached or multifamily attached dwellings under Section 9
, the Energy Code. An alternative to this method for single-family detached dwellings, and multifamily attached dwellings of three stories or less, is
provided in Section 10 of this Code.Only dwellings which are above ground frame(wood siding,brick veneer,etc.)or Concrete wall type construction may
be calculated using Sections 9 and 10.Other types of construction must comply under Section 4 or Section 5 of this Code.Additions to existing residential
buildings shall comply with the requirements of Section 10 of this Code.Detailed information on how to complete this form may be obtained from your local
building department or the Department of Community Affairs,Energy Code Program,2571 Executive Center Circle East,Tallahassee,Florida 32301.
PROJECT NAME I Fairway Villas - Lot 10 Unit 'CGL' PERMITTING OFFICE: Jacksonville
AND ADDRESS: _ __ - -- - -- -------------------
MAY--
_Road _ CIRCLE CLIMATE ZONE: 1 2
BUILDER: Stokes & Co. PERMIT NO.:
OWNER: Stokes & Co. JURISDICTION NO.:
FXI DETACHED IF COVERED MI TH SO,CALCULAUNITTION: , _GLASS AREA AND TYPE-- _
CLEAR TINT,FILM,SOLAR SCREEN
SEPARATE CALCULATIONS ARE REQUIREDf 1 =, 8
SGL SGL
FOR EACH WORST CASE UNIT TYPE.CHECK IF E l--
ATTACHED THIS CALCULATION REPRESENTS A WORST DBL 1— DBL
CASE CONDITION.
NET WALL AREA AND INSULATION CONDITIONED CEILING INSULATION
CBS R= FRAME R= FLOOR AREA UNDER ATTIC SGL.ASSEMBLY
- -11-t- L � �.I__. JtrT1.1 .215161 [1]1 1.1 � l 1 -1_ 9_._�_ R l�1y 1.i.�J R� E 1.�
COOLING SYSTEM PRIMARY HEATING SYSTEM PRIMARY HOT WATER SYSTEM
51
r _ l
g CENTRAL I NONE ELECTRIC STRIP I J GAS NONE ELECTRIC RESISTANCE SOLAR
F—
ROOM I OIL 1 SOLAR ( HEAT RECOVERY -� GAS
- PACKAGE TERMINAL AC HEAT PUMP COP I 2 5 I� 1 DED HEAT PUMP.COP
EER/SEER = ( T7
-8-1
tI 1 OTHER .----_- _ ----_._ - _ - ___-_-- [ - I OTHER: _---- —
CALCULATED E.P.I.: [ 17 1 8 1.1 7 I CALCULATED E.P.I.MUST NOT EXCEED 100 POINTS
In accordance with Section 553.907 FS., I hereby certify that the plans Review of the plans and specifications covered by this calculation indi-
and specifications covered by this calculation are in compliance with the cates compliance with the Florida Energy Code. Before construction is
Florida Energy Code _ �, completed, this building will be inspected for compliance in accordance
n with Section 553.908, F.S.
=-{
OWNER/AGENT J �A _ ___ BUILDING OFFICIAL.
6-I'25-84
DATE: -------.--- --------- ---- DATE: - -----_ - -__ ------------ __ --- --
PRESCRIPTIVE MEASURES(Must be met or exceeded by all residences)
MINIMUM REQUIREMENTS CHECK TO INDICATE
COMPONENTS REQUIREMENTS COMPLIANCE
WINDOWS L903 1) _ MAXIMUM OF 0 5 CFM per LINEAR FOOT OF OPERABLE SASH CRACK
DOORS L903 1) _MAXIMUM OF 0 5 CFM PER SQUARE FOOT OF DOOR AREA INCLUDES SLIDING GLASS DOORS.
EXT.JOINTS&CRACKS(903 1) TO BE CAULKED,GASKETED,WEATHER-STRIPPED OR OTHERWISE SEALED. ✓ _
CEILING INSULATION(903.9) _MINIMUM OF R-19.
WATER HEATERS(903.2) MUST BEAR ASHRAE STANDARD 90-80 LABEL OR A MAX 4 WATT'SO FT STAND-BY LOSS SWITCH
OR CLEARLY MARKED CIRCUIT BREAKER(ELECTRIC)OR CUT-OFF VALVE(GAS)MUST BE
PROVIDED
SWIMMING POOLS(903.3) IF HEATED BY OTHER THAN SOLAR,MUST HAVE POOL COVER DESIGNED TO MINIMIZE HEAT LOSS
ALL NON-COMMERCIAL POOLS MUST BE EQUIPPED WITH A POOL PUMP TIMER N/A
HOT WATER PIPES(903.4) INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS IN SUCH CASES,PIPING HEAT
LOSS SHALL BE LIMITED TO A MAX.OF 17.5 BTU /H PER LINEAR FOOT OF PIPE(SEE 504 4) NSA
_SHOWERHEADS(903 — WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE
HVAC DUCT CONSTRUCTION CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND LOCAL MECHANICAL CODE.
(903.6) DUCTS IN UNCONDITIONED SPACE MUST BE INSULATED TO A MINIMUM R-4 2
HVAC CONTROLS 903 7 A SEPARATE,READILY ACCESSIBLE MANUAL OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM
fi
RESIDENTIAL CALCULATION
FORM 9WA-84 CLIMATE ZONES 1 2 3
COMPONENT WINTER WINOTEER SUMER GROSS
UM ER
AREA x WPM = POINTS AREA x SPM : POINTS
R 0-2.6 31.4 16.2
R 2.7-3.9 19.3 11.5
CONCRETE R 4.0-5.9 15.6 1 9.9
J R6.0&UP 13.1 9.2
J FRAME R 0-10.9 26.1 20.0
3 OR R 11.0-18.9 1256 7.8 9797 1256 9.2 11555
BRICK R 19-25.9 4.9 5.6
VENEER R26&UP 3.6 4.2
COMMON 7.8 2.5
WOOD OR METAL 21 247.7 5205 21 36.4 764
Q INSULATED 235.5 14.5
Q STORM DOOR 124.4 29.0
COMMON 61.9 4.5
R 19-21,9 1197 5.0 5985 1197 5.5 6584
UNDER R 22-29.9 4.1 5.0
ATTIC R 30&UP 3.3 3.7
z
2 R 6-7.9 14.2 14.9
J_ R 8-9.9 10.9 11.3
W SINGLE R 10-11.9 9.2 9.5
V ASSEMBLY
R 12-18.9 8.7 7.0
NO ATTIC R 19-21.9 5.0 5.5
COMMON 4.8 1.5
R 0-6.915.5_ 4.81
V R 7-10.9 8.5 - 2.
t - --- - --- ------ ----- - - - --- ----.1
a WOOD R11-18.9 _ 5.6_. - _ . _--__ _-_1_8_-
U) _.
o R19&UP 4.0 1.3
mo-Z
E R 0-2.9 19.4 -- - ._6.0_
R 3-5.9 12.4 3.7
O R 6-10.9 ----- - 9.3 - - - -- 2.6 --
CONCRETE R 11-18.9 _ _._ -6.2- _ __ _ _ _ _ -___-__ _--____-2.2_._-- --
cr w R19&UP 4.4 1.6
COMMON 4.8 1.5
W EDGE INSULATION PERIMETER WPM
in a R 0-2.9 157 _ 92_7_._ __-14554,--
cc 83-5.9 69.5 --- -
Z PERIMETER R 6 b UP 46.4 - -------- -
O V -
9-34
FORM 9WA44 CLIMATE ZONES 1 2 3
k
WINTER SUMMER
OR AREA SGL DBL MAF GROSS OR AREA SINGLE DOUBLE SOF GROSS
(9F) WINTER CLR TINT CLR TINT (9F) SUMMER
POINTS POINTS
N 15 15 120.8 1.00 2361. N 15 146 123 120 tot 1.001 2190
NE 157.4 120.8 NE 221 186 190 159
E 64 157 120.8 .9 9973. E 64 2 242 251 2o9 .94 17386
3 SE 157.4 120.8 SE 261 219 226 189
S 16 Q-5-7Z 120.8 .7 1914. S 16 ri-935 160 160 134 .91 2766
N SW 157.4 120.8 Sw 261 219 226 189
w2 4 w 23 Cl 5-7-k 120.8 .94 3403. W 23 28 242 251 209 .94 624
N cc W NW 157.4 120.8 NW 221 186 190 159
H 46.4 79.3 H 489 408 432 360
Q
J
V
2
I-
0
2
g Glass Sub-Total 17651. Glass Sub-Total 28590.
H=HORIZONTAL GLASS(SKYLIGHTS). FOR SC OTHER THAN 0.83 SEE SEC.902.2(a)5.TINT MOLT.MAY BE
USED FOR GLASS WITH SOLAR SCREENS FILM OR TINT.
TOTAL GROSS WINTER POINTS 53189. TOTAL GROSS SUMMER POINTS 47483.
R=4.2-4.9 53189 1.14 60635 R=4.2-4.9 47485 1.14 54142
e-J R= 5.0-6.6 1.12 R=5.0_-6.6 1.12
>> R=6.7AUP 1.09 --- R=6.78 UP 1.09
DUCTS IN CONDI- DUCTS IN CONDI-
TIONED SPACE 1.00 TIONED SPACE 100
AV
MSM FROM 9G 160635 x .40 1 2425= FCSM FROM 9H 1 54142 x .83 44938
DIVIDE BY DIVIDE BY
CONDITIONED 24254 _ 1197 20.3 CONDITIONED 44938 - 1197 37.5
FLOOR AREA ( WINTER POINTS FLOOR AREA SUMMER POINTS
CAL ULA-T-E E1 RGY PERF RMAN E_IN EX____
WINTER SUMMER HOT WATER E.P.I. ADJUSTMENT ADJUSTED CREDIT PTS. PENALTY CALCULATED
POINTS POINTS PTS. 91 SUBTOTAL MULTI.L8 E.P.I._ 9C + 9DZ PTS-_f9_E E.P.I.
20.3 + 37.5 _ 0 _ 57.8 x 1.31 _ 75.7 _ 0 + 3 _ 78.7
THE CALCULATED E.P.I.MUST BE EOUAL TO OR LESS THAN 100 POINTS.
98 ADJ ENT Mt IPLIERS _
CONDITIONED901- 1101- 1301- 1501- 1701- 1901- 2101- 2301-
FLOOR AREA(SO.FT.) 0-900 1100 1300 _100_5 1700 1900 2100 2300 ABOVE
ADJUSTMENT 1.21 1.25 1.31 1.36 1.42 1.49 1.57 1.65 1.74
MULTIPLIER
9-35
FORM 900-A44
9C DESIGN CREDIT POINTS CP 90 HEATING SYSTEM CREDIT POINTS
CEILING FAN IN COND SPACE(max 5 CP) t -- NATURAL GAS/PROPANE HEATING ISA
MULTIZONE A/C SEPARATED BY DOOR 5 -- OIL HEATING ILS
CROSS VENTILATION(1 CP per room) 1 --
WHOLE HOUSE FAN(min.1.5 cfm/s.f.) 5 --
WOOD STOVE 7 9E DESIGN PENALTY POINTS
FIREPLACE WITH OUTSIDE COMBUSTION AIR 2 -- WASHER AND DRYER IN COND SPACE 3
TOTAL GLASS OPENS LESS THAN 40% 5
9C TOTAL(not to exceed 12 points) 0 FIREPLACE WITH INSIDE COMBUSTION AIR 5
9F WINTER OVERHANG FACTOR 9F SUMMER OVERHANG FACTOR SO
ET N NE E SE S SW W NW FEET N NE E SE S SW W NW
0-0.9 1.00 0.98 0.99 0.74 0.71 0.82 0.93 1.00 0-0.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
3-3.9 1.00 0.9896
.8 0.� 0.81 0.79 0.87 1.00 3-3.9 0.95 0.88 0 91 0.86 0.69 0.95
4-4.9 1.00 0.98 0.99 0.84 0.83 0.89 0.94 1.00 4-4.9 1.00 0.91 0.84 0.80 0.82 0.80 0.64 0.91
5-5.9 1.00 0.99 1.00 0.87 0.87 0.92 0.95 1.00 5-5.9 0.99 0.88 0.79 0.76 0.79 0.76 0.79 0.88
6-6.9 1.00 0.99 1.00 0.90 0.90 0.93 0.96 1.00 6-6.9 0.99 0.85 0.75 0.73 0.78 0.73 0.75 0.85
7-7.9 1.00 0.99 1.00 0.93 0.94 0.96 0.97 1.00 7-7.9 0.99 0.83 0.72 0.70 0.77 0.70 0.72 0.83
8-8.9 1.00 0.99 1.00 0.95 0.96 0.97 0.98 1.00 8-8.9 0.99 0.81 0.70 0.68 0.77 0.68 0.70 0.81
9-9.9 1.00 1.00 1.00 0.97 0.98 0.98 0.98 1.00 9-9.9 0.98 0.79 0.68 0.67 0.76 0.67 0.68 0.79
10-10.9 1.00 1.00 1.00 0.99 0.99 0.99 0.99 1.00 10-10.9 0.98 0.77 0.66 0.66 0.76 0.66 0.66 0.77
11-11.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 11-11.9 0.97 0.76 0.64 0.64 0.76 0.64 0.64 0.76
12 UP 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 12 UP 0.97 0.75 0.63 0.64 0.76 0.64 0.63 0.75
913 1 HEATING SYSTEM MULTIPLIER HSM
HEAT PUMP COP I Gi7lb2.7-2.8 2.9-3.0 3.1-3.2 3.3-3.4 3.5 A UP
HSM .37 .34 _.32 .30 .29
SOLAR HEATING SYSTEM _ (BACKUP SYSTEM FRACTION) x (BACKUP SYSTEM HSM)
ELECTRIC STRIP HEAT _ 1.0
NATURAL GAS/PROPANE/OIL - 1.0(SEE TABLE 90 FOR CREDITS) _
PTAC&ROOM HEAT PUMPS MINIMUM COP 2.2.HSM FOR COP 2.2- 2.4=•.45.
SEE TABLE ABOVE FOR COP> 2.4
9H
COOLING SYSTEM MULTIPLIER CSM
ELECTRIC EERISEER 7 8.0-8.4 8.5-8.9 9.0-9.4 9.5-9.9 10.0-10_4 10.5-10.9 111.0-11.9 12.0-UP
CSM 83 .81 0.78 0.T2 0.68 0.85 0.82 0.59 0.54
GAS COP 0.40-0.44 0.45-0.49 0.50-0.54 0.5S-0.59 0.60-0.64` 0.65-0.69 0.70 d UP
CSM 1.50 1`25_ 1.20^ - 1.09 _ 1.00- 0.92 0.89
MINIMUM SEER/EER LEVEL 7.8 FOR STRAIGHT COOL OR HEAT PUMPS;MINIMUM OF 7.5 EER FOR ROOM UNITS AND PTAC.
FOR ROOM UNITS AND PTAC CSM FOR EER 7.5- 7.7= .87.SEE TABLE ABOVE FOR EER -7.7.
91 1 HOT WATER CREDIT POINTS HWCP
ELECTRIC RESISTANCE WATER HEATER
GAS WATER HEATER _ - 10
INSTANTANEOUS WATER ELECTRIC 4.5
HEATER GAS 12.6
HRU(AIC)WATER HEATER _ELECTRIC BACKUP 6.7
GAS BACKUP 13.9
HRU(HP)WATER HEATER ELECTRIC BACKUP 9.7GAS BACKUP _ 14.5
HEAT PUMP WATER HEATER COP 1.60-1.89 1.90-2.19 2.20-2.4_9 2.50-2.79 2.80-3.00
(DEDICATED HEAT PUMP) CREDIT POINTS 9.0 11.4 13.1 14.4 15.4
OVERALL SOLAR FRACTION* 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
SOLAR c= ELECTRIC BACKUP 2.4 4.8 7.2 9_6 12.0 14.4 16.8 19.2 21.6 24.0
NOT WATER EE I GAS BACKUP 11.4 12.8 14.2 15.6 17.0 18.8 19.8 21.2 22.8 24.0
•PERCENT OF ANNUAL HOT WATER PROVIDED BY SOLAR SYSTEM +100=OVERALL SOLAR FRACTION
9-35
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
SECTION 9—RESIDENTIAL POINT SYSTEM METHOD CLIMATE ZONE
FORM 900-A-84 DEPARTMENT OF COMMUNITY AFFAIRS NORTH t 2 9
his form may be used to demonstrate compliance with the Energy Code for new single-family detached or multifamily attached dwellings under Section 9
, the Energy Code. An alternative to this method for single-family detached dwellings, and multifamily attached dwellings of three stories or less, is
provided in Section 10 of this Code.Only dwellings which are above ground frame(wood siding,brick veneer,etc.)or Concrete wall type construction may
be calculated using Sections 9 and 10.Other types of construction must comply under Section 4 or Section 5 of this Code.Additions to existing residential
buildings shall comply with the requirements of Section 10 of this Code.Detailed information on how to complete this form may be obtained from your local
building department or the Department of Community Affairs,Energy Code Program,2571 Executive Center Circle East,Tallahassee,Florida 32301.
PROJECT NAME Fairway Villas - Lot 10 Unit 'CGL' PERMITTING OFFICE: Jacksonville
AND ADDRESS: 1_Maport Road CIRCLE CLIMATE ZONE: 1 2
BUILDER: Stokes & Co. PERMIT NO.:
OWNER: Stokes & Co. JURISDICTION NO.:
DETACHED IF MULTIFAMILY,NO.OF UNITS GLASS AREA AND TYPE
OCOVERED BY THIS CALCULATION: �- I_ _--J _ CLEAR
—ASR--- TINT,FILM,SOLAR SCREEN
SEPARATE CALCULATIONS ARE REQUIRED ( i 1 , I I SGL -�� SGL
FOR EACH WORST CASE UNIT TYPE.CHECK IF ❑ t_L -1-1 8 I
ATTACHED THIS CASE CONDITION.CALCULATION REPRESENTS A WORST �� DBLFT
DBL
NET WALL AREA AND INSULATION CONDITIONED CEILING INSULATION
CBS R= FRAME R= FLOOR AREA UNDER ATTIC SGL.ASSEMBLY
IF]IFN ?I 516=1 �1�1 J.� U I i_1 . 9 R-1 _9 l�l R= FT].[]
COOLING SYSTEM PRIMARY HEATING SYSTEM PRIMARY HOT WATER SYSTEM
X l CENTRAL I - NONE I ELECTRIC STRIP I J GAS NONE I X I ELECTRIC RESISTANCE ❑ SOLAR
ROOM I OIL SOLAR I HEAT RECOVERY Ll GAS
1_ PACKAGE TERMINAL AC I I HEAT PUMP COP I 2 I I .5 I I DED. HEAT PUMP.COP
J _ L J 111 111 l
EER/SEER = 7 8 OTHER —__—_ —__ l -_J OTHER:
CALCULATED E.P.I.: [ �� -1 8] l 7 , CALCULATED E.P.I.MUST NOT EXCEED 100 POINTS
In accordance with Section 553.907 FS., 1 hereby certify that the plans Review of the plans and specifications covered by this calculation indi-
and specifications covered by this calculation are in cwwliance with the cates compliance with the Florida Energy Code. Before construction is
Florida Energy Code�Cc-
completed, this building will be inspected for compliance in accordance
with Section 553.908, F.S.
OWNER/AGENT - . ._._. ___— BUILDING OFFICIAL
DATE: 6-25-84 DATE
9A PRESCRIPTIVE MEASURES(Must be met or exceeded by all residences I
MINIMUM REQUIREMENTS CHECK TO INDICATE
COMPONENTS REQUIREMENTS COMPLIANCE
WINDOWS(903_1 _ MAXIMUM OF 0 5 CFMper LINEAR FOOT OF OPERABLE SASH CRACK
DOORS 903 1 MAXIMUM OF 0 5 CFM PER SQUARE FOOT OF DOOR AREA INCLUDES SLIDING GLASS DOORS
EXT.JOINTS 8 CRACKS(903 1) TO BE CAULKED,GASKETED,WEATHER-STRIPPED OR OTHERWISE SEALED. We _
CEILING INSULATION(903.9) MINIMUM OF R-19. V
WATER HEATERS(903.2) MUST BEAR ASHRAE STANDARD 90.80 LABEL OR A MAX 4 WATT'SQ FT STAND-BY LOSS SWITCH
OR CLEARLY MARKED CIRCUIT BREAKER(ELECTRIC)OR CUT-OFF VALVE(GAS)MUST BE
PROVIDED V
SWIMMING POOLS(903 3) IF HEATED BY OTHER THAN SOLAR.MUST HAVE POOL COVER DESIGNED TO MINIMIZE HEAT LOSS
ALL NON-COMMERCIAL POOLS MUST BE EQUIPPED WITH A POOL PUMP TIMER N/A
HOT WATER PIPES(903.4) INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS IN SUCH CASES,PIPING HEAT
LOSS SHALL BE LIMITED TO A MAX.OF 17 5 BTU /H PER LINEAR FOOT OF PIPE(SEE 504.4). N/A
SHOWER HEADS X903 5 — — WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE ►�
-- - _ .._ _. -------
HVAC
-.HVAC DUCT CONSTRUCTION CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND LOCAL MECHANICAL CODE.
(903 6) DUCTS IN UNCONDITIONED SPACE MUST BE INSULATED TO A MINIMUM R-4 2
HVAC CONTROLS(903 7) A SEPARATE.READILY ACCESSIBLE MANUAL.OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM
RESIDENTIAL CALCULATION
FORM 900•A-84 CLIMATE ZONES 1 2 3
COMPONENT WINTER GROSS SUMMER GROSS
WINTER ~� SUMMER
AREA x WPM = POINTS AREA x SPM = POINTS
R 0-2.6 31.4 16.2
R 2.7-3.9 19.3 11.5
CONCRETE R 4.0-5.9 15.6 9.9
N R6.08UP 13.1 9.2
J
J FRAME R 0-10.9 26.1 20.0
OR R 11.0-18.9 1256 7.8 9797 1256 9.2 11555
BRICK R 19.25,9 4.9 5.6
VENEER R 26 8 UP 3.6 4.2
COMMON 7.8 2.5
WOOD OR METAL 24T.7 5205 21 36.4 764
Q INSULATED 235.5 14.5
STORM DOOR 124.4 29.0
COMMON 61.9 4.5
R 19-21.9 1197 5.0 5985 1197 5.5 6584
UNDER R 22-29.9 4.1 5.0
ATTIC R 30 8 UP 3.3 3.7
z R 6-7.9 14.2 14.9
2
_1 R 8-9.9 10.9 11.3
W SINGLE R 10-11.9 9.2 9.5
V ASSEMBLY
R 12-18.9 8.7 7.0
NO ATTIC R 19-21.9 5.0 5.5
COMMON 4.8 1.5
R 0-6.915.5_ 4.8
--
U A 7-10.9 8.5 -- -------- -------- - 2.1
t - - - ----- - ---- ---
a WOOD R 11-18.9 5.6 1.8
d R198UP 4.0 1.3
W - -------- - - - - ------- - ----- - --
m Z
R 0-2.9 - 19.4 - -- ---6.0
a R 3-5.9 12.43.7
LL 0
V R 6-10.9 --- ---9.3 - - - - - -- -- 2.6_.
CONCRETE R 11-18.9 6.2
¢ R 19 8 UP ---- - 4.4 - -- 1.6
COMMON 4.8 1.5
W EDGE INSULATION PERIMETER WPM
gQ RG-2.9 157 927_ 14554
R 3-5.9 69.5 - -- -
Z PERIMETER R 6 8 UP 46.4 - -- _ -
p -- --- -
9-34
..
FORM 900-A44 CLIMATE ZONES 1 2 3
WINTER SUMMER
OR AREA SGL DBL WOF GROSS OR AREA SINGLE I DOUBLE SOF GROSS
(9F) WINTER CLR TINT I CLR TINT (9F) SUMMER
POINTS POINTS
N 15 Gip 120.8 1.00 2361. N 15 146 123 1 120 101 1.001 2190
NE 157.4 120.8 NE 221 186 190 159
E 64 157 120.8 .99 9973. E 64 C2- 242 251 209 .94 17386
Z- SE 157.4 120.8 SE 261 219 226 189
< S 16 157 120.8 .76 1914. S 16 CK 160 160 134 .91 2 766
N SW 157.4 120.8 SW 261 219 1 226 189
¢ W 23 157 AY 120.8 .94 3403. W 23 28 242 251 209 .94 6248
0
N W NW 157.4 120.8 NW 221 186 190 159
N H 46.4 79.3 H 489 408 432 360
g�
Z
0
Z
g Glass S -Tot 1 17651. GlassSub-T tal
H=HORIZONTAL GLASS(SKYLIGHTS). FOR SC OTHER THAN 0.83 SEE SEC.902.2(o)S.TINT MOLT.MAY BE
USED FOR GLASS WITH SOLAR SCREENS FILM OR TINT.
TOTAL GROSS WINTER POINTS 53189. TOTAL GROSS SUMMER POINTS 47483.
R=4.2-4.9 53189 1.14 60635 R =4.2-4.9 47485 1.14 54142
r J R=5.0-6.6 1.12 R =5.0-6.6 1.12
>> R=8.7&UP 1.09 - R =6.76 UP 1_09
DUCTS IN CONDI- DUCTS IN CONDI-
TIONED SPACE 1.00 T10NEO SPACE 1.00
HSMFROM9G 160635 x .40 1 24254 CSM FROM 9H 54142 x .83 44938
DIVIDE BY DIVIDE BY
CONDITIONED 24254 _ 1197 20.3 CONDITIONED 44938 - 1197 37.5
FLOOR AREA WINTER POINTS FLOOR AREA SUMMER POINTS
UI�TE EN RAY PR FRMANE_INC ___
WINTER SUMMER HOT WATER E.P.I. ADJUSTMENT ADJUSTED CREDIT PTS. PENALTY CALCULATED
POINTS POINTS PTS. 91 SUBTOTAL MU j. 991 _E.P.I. 9C+ 9DL PTS. 9E E.P.I.
20.3 + 37.5 _ 0 _ 57.8 x 1.31 _ 75. 7 _ 0 + 3 _ 78.7
THE CALCULATED E.P.I.MUST BE EQUAL TO OR LESS THAN 100 POINTS.
ADJU IPLIER ---CONDITIONED 901- 1101- 1301- 1501- 1701- 1901- 2101- 2301-
FLOOR AREA(SQ.FT.) 0-900 1100 1300 _1_500 1700 1900 2100 2300 ABOVE
ADJUSTMENT 1.21 1.25 1.31 1.36 1.42 1.49 1.57 1.65 1.74
MULTIPLIER
9-35
FORM 900-A-IM
9C DESIGN CREDIT POINTS CP 90HEATING SYSTEM CREDIT POINTS
CEILING FAN IN COND SPACE(max 5 CP) 1 -- NATURAL GAS/PROPANE HEATING 10.0
MULTIZONE AIC SEPARATED BY DOOR 5 OIL HEATING me
CROSS VENTILATION(1 CP per room) 1 --
WHOLE HOUSE FAN(min.1.5 ctmis.t.) 5 --
WOOD STOVE 7 -- 9E DESIGN PENALTY POINTS
FIREPLACE WITH OUTSIDE COMBUSTION AIR 2 -- WASHER AND DRYER IN COND SPACE 3
TOTAL GLASS OPENS LESS THAN 40% 5
9C TOTAL(not to sxawd 12 points) 0 FIREPLACE WITH INSIDE COMBUSTION AIR 5
9F WINTER OVERHANG FACTOR 9F SUMMER OVERHANG FACTOR SO
ET N NE E SE S SW W NW FEET N NE E SE S SW W NW
0-0.9 1.00 0.98 0.99 0.74 0.71 0.82 0.93 1.00 0-0.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1-1.9 1.00 0.98 0.99 0.75 0. 0.83 0.93 1.00 1-1.9 1.00 1.00 0.99 0.98 0.97 0.98 1.00
2-2.9 1.00 0.98 099 0.77 .76 0.84 1.00 2-2.9 0.98 ( ') 0.92 .91 0.92 0� 0.98
3-3.9 1.00 0.98 0.81 0. 9 0.87 0.94 1.00 3-3.9 1.00 0.95 fig§ 0.86 �5 0.86 0.89 0.95
4-4.9 1.00 0.98 0.99 0.84 0.83 0.89 0.94 1.00 4-4.9 1.00 0.91 0.84 0.80 0.82 0.80 0.84 0.91
5-5.9 1.00 0.99 1.00 0.87 0.87 0.92 0.95 1.00 5-5.9 0.99 0.88 0.79 0.76 0.79 0.76 0.79 0.88
6-6.9 1.00 0.99 1.00 0.90 0.90 0.93 0.96 1.00 6-6.9 0.99 0.85 0.75 0.73 0.78 0.73 0.75 0.85
7-7.9 1.00 0.99 1.00 0.93 0.94 0.96 0.97 1.00 7-7.9 0.99 0.83 0.72 0.70 0.77 0.70 0.72 0.83
8-8.9 1.00 0.99 1.00 0.95 0.96 0.97 0.98 1.00 8-8.9 0.99 0.81 0.70 0.68 0.77 0.68 0.70 0.81
9-9.9 1.00 1.00 1.00 0.97 0.98 0.98 0.98 1.00 9-9.9 0.98 0.79 0.68 0.67 0.76 0.67 0.68 0.79
10-10.9 1.00 1.00 1.00 0.99 0.99 0.99 0.99 1.00 10-10.9 0.98 0.77 0.66 0.66 0.76 0.66 0.66 0.77
11-11.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 11-11.9 0.97 0.76 0.64 0.64 0.76 0.64 0.64 0.76
12 UP 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 12 UP 0.97 0.75 0.63 0.64 0.76 0.64 0.63 0.75
9G HEATING SYSTEM MULTIPLIER HSM
HEAT PUMP COP S-2. 2.7-2.8 1 2.9-3.0 3.1-3.2 3.3-3.4 3.5&UP
HSM 37 .34 .32 .30 .29
SOLAR HEATING SYSTEM (BACKUP SYSTEM FRACTION) x (BACKUP SYSTEM HSM)
ELECTRIC STRIP HEAT[7
NATURAL GAS/PROPANE/OIL __ J 1 0(SEE TABLE 90 FOR CREDITS)
PTAC a ROOM HEAT PUMPS MINIMUM COP 2.2.HSM FOR COP 2.2- 2.4=-.45.
SEE TABLE ABOVE FOR COP> 2.4
9H COOLING SYSTEM MULTIPLIER(CSMA
ELECTRIC EERISEER 7 8.0-8.4_1 8.5-8.9 1 9.0-9.4 9.5_-9.9_ 10.0-10.4 10.5-10.9 11.0-11.9 12.0-UP
CSM .83 .81 0.78 _0.72 _0.68_ 0.65 _0.62 0.59 0.54
GAS COP 0.40-0.44 0.45-0.49 0.5_0-0.54 0.55-0.59 0.60-0.64 0.85-0.69 0.70 A UP
CSM 1.50 1,25 1.20 _ 1.09 1_00--�_ 0.92 _0.89
MINIMUM SEEP/EER LEVEL 7.8 FOR STRAIGHT COOL OR HEAT PUMPS;MINIMUM OF 7.5 EER FOR ROOM UNITS AND PTAC
FOR ROOM UNITS AND PTAC CSM FOR EER 7.5-7.7 = .87.SEE TABLE ABOVE FOR EER 7.7.
91 1 HOT WATER CREDIT POINTS HWCP
ELECTRIC RESISTANCE WATER HEATER _ CO-)
GAS WATER HEATER _ 10
INSTANTANEOUS WATER ELECTRIC4.5
HEATER GAS -_ _ �----- - 12.6
ELECTRIC BACKUP ---�-�-'-_-�_--_-----_ i-- 6.7
HRU(AIC)WATER HEATER GAS BACKUP _ 13.9
ELECTRIC BACKUP i 9.7
HRU(HP)WATER HEATER GAS BACKUP 14.5
HEAT PUMP WATER HEATER COP 1.60-1.89 1.90-2.19 2.20-2.4_9 2.50-2.79 2.80-3.00
(DEDICATED HEAT PUMP) CREDIT POINTS 9.0 11.4 13.1 14.4 15.4
OVERALL SOLAR FRACTION' 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
SOLAR o= j ELECTRIC BACKUP 2.4 4.8 7.2 9.6 12.0 14.4 16.8 19.2 21.6 24.0
HOT WATER ff 1 GAS BACKUP 11.4 12.8 14.2 15.6 17.0 16.8 19.8 1 21.2 1 22.8 24.0
*PERCENT OF ANNUAL HOT WATER PROVIDED BY SOLAR SYSTEM t 100=OVERALL SOLAR FRACTION
9-36
INSPECTION LOG
JOB ADDRESS
CONTRACTOR
OWNER
BUILDING PERMIT &OC') ELECTRICAL PERMIT
PLUMBING PERMIT TEMPORARY POLE PERMIT
MECHANICAL PERMIT MISCELLANEOUS PERMIT
FLOOD ZONE DATE SURVEY FILED ,SCJ
Called-In Approved J.E .A.
Temp Pole
Footing
Slab C ow
Framing
Plumbing (R)
Electrical (R)
Mechanical
Fireplace
Top out
Other
Electrical (F)
FINAL INSPECTION
Certificate of Occupancy Issued
C0121ENTS :
OT: ------- ----- - - --- -
x)):(:)1:1\1 CAL: - ——-- — ---
-- h1.E0 h1 CAl.:
BUILDING PE}•AI T 1:'O};1;S){}ET
per- sq. f t
SQUARE FOOTAGE: �d� � @ $ " . _ $
�lEATEll _-- _ — - --- -
;:;:RAGE (PH I VATE/SHED) : -- — per q• ft. - - —
CARPORT: _ _ @ $ - per sq. ft.
PORCHES: _ @ $ _ per sq. ft.
DECK: — -- @ $ — — ---- per sq. ft. _ $ --
PAT10: _ _— @ $ � -- -- per sq. ft. _ $- -------
TOTAL VALUATION:
PERAIT FEES
TOTAL \ALL'AT 10\ DATA 1st
_ $ 77 S�
REHAI',DER VALUATION @ thousand
or portion thereof
TOTAL BUILDI':G PERMIT FEE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $
PLUS 2 THE BUILDING PER1•1IT FOR PLAN FILING FEE. . . . . . . . . . . $
TOTAL FEE DUE- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • . . . $ - ----
----------------------------------------------------------------------------------------------
PLC-'BING PERMIT FEE: $ lx�7 J. Cr-' \-ICAL PER..JIT FEE:
EI-ECIRICAL RESIDENTIAL: $ ELECTRICA1 TE','POR4RY: $ —_—
DATER METER SIZE: FEE: $
SE1,ER CONNECTION CHARGE: SQUARE FOOTAGE: FEE S
EATER CONNECTION CYARGE: FIXTURE L'NITS $10. 00 PER bNIT: $
ACCOL;NT NO- :
APPROVED BY: TOTAL BUILDI`:G/FLAN FILI\G FEES: $ �c.�
TOTAL '.•TATER -'E--,-TR CHAP.GE:
TOTAL WATER CO"':ECT10\ C12--4RGE:
•-, � TOTAL SEWER CO':':ECTIO\ C::-aRGE:
GRAND TOTAL DUE: