Loading...
Permit 2221 Fairway Villas N 1j\54:i'.1 CITY OF ATLANTIC BEACH 800 SEA/I:MOLE ROAD ) , ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 -7 ' , 1 I , Application Number 06-00033532 Date 9/19/06 Property Address 2221 FAIRWAY VILLAS LN Tenant nbr, name I REPLACE WINDOWS Application type description RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning TO BE UPDATED Application valuation . . . 5208 Owner Contractor ENDEREZ, NOLASCO LOWE'S HOME CENTERS INC 2221 FAIRWAY VILLAS LN 12945 ATLANTIC BLVD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 486-4701 Permit BUILDING PERMIT Additional desc . Permit Fee . . . 60.00 Plan Check Fee . . 30.00 Issue Date . . . Valuation . . . . 5208 Expiration Date . 3/18/07 - , Fee summary 4harged Paid Credited Due 1 , ■ Permit Fee Total 60.00 60.00 .00 .00 Plan Check Total 30.00 30.00 .00 .00 Grand Total 90.00 90.00 .00 .00 I I; I I ' I PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. NOTICE OF COMMENCEMENT State of � Op ) fr Tax Folio No. County of ?um L To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes, the following information is stated in is NOTICE OF COMMENCEMENT. L EMS t Ave Legal Description of property being improved: 'Z2 being improved: 2�2 Pk /RW/1 1IU rf It). N. „4 1; 5 f ` ,3. 2 ,33 Address of property gimp • y , General description of improvements: Owner. PPG 4', ' C 0 1,? - - e - A) 4PE Z. Address* 2 ;2/ fh1/24 I Im.S AV. N • /)/1/*'1k- Bat-41R- • 3. Owner's interest in site of the improvement: .24/11--4- /ertAXX./A Fee Simple Titleholder (if other than owner): Name: n l.eli9Fs - T T.As e..- A. cAr- ifac 1�,' , Contractor: /�, j • 3 2-Z Z� ��L P Address: [ Z�`f p S' ��t�� (- <�1 L1) D - ��� f_ -4'7 [ � Telephone No.: lL* 4' %' 4701 Fax No 6 Surety (if any) Amount of Bond $ Address: Telephone No: Fax No: Name and address of any person making a loan for the constriction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) - -- •- -- - Name: Address: '` 4 ;� �, r . Fax No � '� . nlr,►Mk - a r, Telephone No: ' Expiration date of Notice of Commencement (the expiration date is one (1) year from the .. a I g ����,. specified): /� / teazimp THIS SPACE FOR RECORDER'S USE ONLY OWNER '� A O / • P /0-0 Signed: ' / �' . Date. g.zq .6 & Before me this 0, o L� 1.c.. ST in the County of Duval, State / Of Florida, has personally : ."7"-: ed Doc # 2006326682, OR BK 13527 Page 1716, / ', , — — -- _i- Notary Public at Large, State of Florida, Co ty of Duval. L ,y _— M commission expires: • / . / u OT Number Pages: Filed ecorde d 09/19/2006 at 09:47 AM, Personally Known: . .,1' I r JIM M d �... FULLER CLERK CIRCUIT COURT DUVAL COUNTY Produced Identification: RECORDING $10.00 CITY OF ATLANTIC BEACH c s PLAN REVIEW SHEET Routed to: i yr Building Department Public Works & Public Utilities Departments L.Higgins �t J,il�r 800 Seminole Road 1200 Sandpiper Lane • ' • - Atlantic Beach, Florida 32233 Atlantic Beach, Florida 32233 R. Carper (904) 247 -5800 (904) 247 -5834 D. Kaluzniak (904) 247 -5845 Fax (904) 247 -5843 Fax Public Safety PLAN REVIEW COMMENTS Permit Application # 0(.0 Property Address: RA I Fa vwa V i 111 4- LO ni Al. Applicant: I... 0 W e Project: &p/aet LVir/bU - This permit application has been: /' b X Approved as noted by the latP Department. final application approval must come from the Building Department. i.ri.i Reviewed and the following items need attention: I) UJ `n; i s b c2ec.. e51 5 t4 (A., t c oovu A Qty S, ' 1►-t9 (-14Z 5 2. 44 — a b Z, , / Oc t ). l&.uP— ii- ldkror c(- ■) Ft a, Ft L L 14 1-j ��4 k K._ eco ozce c ' ' ,,∎1;7wc `(m 4- p i-Si 4-\ Tc wti 1 AWLtc cc.i teq) - s rii /4t' /22 --- V Please re- submit your application when these items have been completed. Reviewed By: Date: _ ll zot & Cr ' i Y ' Date Contractor Notified: -Q (Of h k i jCITY OF ATLANTIC BEACH . :_. t` w WINDOWS, SKYLIGHTS, GARAGE DOORS, HURRICANE SHUTTERS �U, ;s Date: Job Address: .22-2 -/ 1/1-) 411i ha 4. 12M7 meg- / �. 9.2_23 Owner: A & 1 -- 0 p' 5Aj75 7-- Address: A2-9./? Mhatt i4t L. ,/. /47' 7 1174 /agne: 3 7,.2:-bo3S - Legal Description: Block Number; Lot Number: Zoning Dist ict: Contractor: LOW 6 ! , T 5 � r` " ( 0 State License Number: C I .9 V' 7 r / 9 «.T All. 4G / 1i ` / it- 2 2 J Ph one : 9 6 i l c/70 / Address: , / j ` City: a tate: X.__ Zip: J Z 2 .) -- Fax: Y� 1 ) «7/ 0 Describe proposed use and work to be done 0 r / / A 04 j ai(4,411,,e, Present use of land or building(s): a blir _ Valuation of proposed construction: / t' °' Is approval of Homeowner's Association or other private entity required? If yes, please submit with this application. Required Building Data: Mean Roof Height (ft) Building Width (ft) Building Length (ft) Roof Slope Window Height (ft) Window Width (ft) Window Elevation from Grade (ft) Measurement from corner of building to window (ft) Number of windows being installed Mean Roof Height 800 Seminole Road • Atlantic Beach, Florida 32233 - 5445 Phone: (904) 247 -5800 • Fax: (904) 247 -5845 - http : / /www.ci.atlantic- beach.fl.us Revised 1/27/03 Page 1 HP Officejet 7410 Log for Personal Printer /Fax/Copier /Scanner Information Systems 904 -247 -5845 Aug 22 2006 8:41 AM Last Transaction Date Time Type Identification Duration Pages Result Aug 22 8:40AM Fax Sent 94864710 0:40 2 OK ' Procedure: In order to expedite issuance of permits provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. In addition to the building data, the following information is required: 1. Manufacturer's Test Report with Uniform Structural Load (psf) 2. Installation Procedures 3. Window Description/Type 4. Garage Door Description/Type 5. Skylights Description/Type 6. Hurricane Shutter Description/Type 7. Elevation View of Window Locations I hereby certify that all info ation provided with this application is correct. Signature of Owner: hiz Ai' 1),, Date: V r �QP� l I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal, state or local rules, regulations, ordinances, or laws in any manner, including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the s mss and supporting data have been or shall be provided as required. Signature of Contractor: o i"l am t i l i?j, „ Date: 7ific:., Address and contact information of person to receive all correspondence regarding this application (please print). Name: / /4 " /2 A -2 L - t— / 9 VI �` t7� c.._ ' & /5 J 4- rl__ . 22 Z- f Mailing Address: /� J 9 7` , ! [� Telephone: gd y tee 4 ( I Fax: q'C 7 P' CI 7 / 0 E -Mail: AS TO OWNER: Sworn to and subscribed before me this ,j day of f^ , 20 Q . State of Florida, County of Duval ? 01.''x, Corinne Hundley aCtit-4-4kA , = a \ Commission # DD427539 Notary's Signature: 1 , ,,, ,: 4:t'` R �`: Expires May 13, 2009 '4 • . ' •`� Bonded Troy Fan - Insurance, Inc. 800-385-7019 ❑ Personally known [ 'Produced identification _ Type of identification produced NI-GAL ( (I-it R F -- 1-4 - _ - _/u_ b .1.-L AS TO CONTRACTOR: - Sworn to and subscribed before me this ( day of _J(1. ij ,, 20 State of Florida, County of Duval � N Signs ' K. CUNNINGHAM ` d' P Notary Public - Stele of Fouls Alt` Z F 21, . . , j -- P'�rsonally known ,? Commission ADD 523636 ❑ Produced identificatio • „q;., ^,.•" Bonded : National • Aim Type of identification produced 800 Seminole Road Atlantic Beach, Florida 32233 -5445 Phone: (904) 247 -5800 Fax: (904) 247 -5845 http : / /www.ci.atlantic- beach.fl.us Page 2 Revised 1/27/03 ■ ow� Home Improvement Warehouse Improving Home Improvement 8529 South Park Cr. Suite 430 Orlando, Florida 32819 Bus. 407/370 -2872 Fax. 407/352 -6309 Limited Power of Attorney Date: To: Building Department From: Peter Anthony Cafaro III I hereby name and appoint Maria O'Reilly, of Lowe's Home Centers, Inc. to be my lawful attorney in fact to act , for me to register my license and apply to .610 cribe Ga l- for a ate/114a) permit for work to be performed at a location de d as: , '� (Address of Job) �j G- /a4(-? ,: (Owner of Property) p „7 / And to sign my name and do all things necessary to this appointment. Thank you for your assistance. Sincerely, . / Peter Anthony Cafaro Area Installed Sales Manager Primary State Qualifi CGC 1 18417 o p, Sw•rn to and subscr before me this day of 005. .o�g . Rebecca Velez No.public �' .*__ MYCOMMISSION# DD176963 - XP :.^c' My commission expires ''u”' .�� January 12, 2007 Cli . A V� 8ONDEDTHRUTROYFAININSURANCE,INC 2006 -08 -24 09:09 (904)- 486 -4710 1699 - INST 2/3 PAGE AL SALES P 2/ 0B/17/200& 03;54 9044069341 SHAWN ANDREWS, INC 2 ._—' - 1:30 (9 04) -486 -4710 1699 - INSTALLED SALES A 2/2 ,s4s, . CITY OF ATLANTIC BEACH r WINDOWS, S YLYGurs, GARAGE DOM, HURRICANZ SA l' ER8 • Job Mc ss: ri - • • � I t0 ' - • Addre. 2,� 1 at/i La1~ �• Af1//' I , 5doe: .22 tad9s" Zoei D �x• Co ws "7'7• iff Liq+nret� Addeo= 2 2 . 7 Phosa Q ' City: 4 /L .. v 3*3 .r pea: 77 0 •De Bribe proposed use sod work to be , lf� i ,•' .1 - Present on of Lod or Wilding* r - • Valuation of proPosc+d emmmtvetios: ti7 v* ie _ 11 approval of Tiomeowser's Aseooiatiaa at aft prim atity required? Fyn, plow admit with this 1pPiiortion- >red »sadtss ]tress: Mesa > aa** _3&;1,0q Waft WIdtb 044 &dam R,of she df l tl. wisdom Med _.. __...,....,.. Window wide {1y wladew SWAIN, ire reo Grade 1t.. 414 1fi.:are t beadles le whitlow b . pq Nester et 1;i rdoers Wog b staled Ficonr— I.ad ,N6e41 sER'rFS �u � .— brr�lawi?vr -iris 10 C�4. jC , racgu 5�R1 �`J J u, • 1N�oReetllei� bac- = 2,N1Rooz- 0101. o p r ,( rams -6ei yis 04 se. Wok head • Alm* • Tege1 eevkai1/11103 • t'd 9,99-41a1011 guagq.A0 utnw volul eor90 90 at Dro► J- REVI ED X110 2006 - - 09:09 (904)- 486 -4710 1699 - INSTALLED SALES P 3/3 46114111 run e rx FQQ0.J� 4AVM OiC 1a 4164, To 644 ID To 7"1 a En Z III 2 ft , Str fr `o �^ - c lW l W 41� RE ISED II,I/ob Architectural Testing NOTICE THIS DOCUMENT IS BEING PROVIDED FOR THE LIMITED PURPOSE OF OBTAINING BUILDING CODE APPROVAL. ACTUAL TEST RESULTS PROVIDED HERIN SUPPORT AND. IN SOME CASES, EXCEED PUBLISHED PERFORMANCE CLAIMS. SEE PRODUCT LITERATURE FOR COMPLETE PERFORMANCE INFORMATION. ANSLAAMA/NWWDA 101/LS.2 TEST REPORT Rendered to: PELLA WINDOWS AND DOORS SERIES/MODEL: 25 TYPE: Vinyl Double Hung Window FILE COPY a REV SED Summary of Results Title Test Specimen #1 Test Specimen #2 AAMA Rating H -R25 48 x 72 H: R40* 36 x 62 Operating Force 241b max. 14 lb max. Air Infiltration 0.25 cfm/ft 0.27 cfm/ft Water Resistance Test Pressure 5.25 psf 6.0 psf Uniform Load Deflection Test Pressure +25.0 psf +40.0 psf Uniform Structural Load Test Pressure +37.5 psf +60.0 psf Forced Entry Resistance Grade 10 NIA Reference should be made to ATI Report No. 01- 47446.01 for complete test specimen description and data. 130 Derry Court York, PA 17402 -9405 phone 717.764.7700 fax 717.764.4129 www,archtest.com 1 • Architectural Testing NNSI/AAMA /NWWDA 101/LS.2 -97 TEST REPORT Rendered to: PELLA WINDOWS AND DOORS 2000 Praline Place Gettysburg, Pennsylvania 17325 Report No: 01- 47446.01 Test Dates: 10/09/03 And: 11/14/03 Report Date: 12/15/03 Expiration Date: 11/14/07 Project Summary: Architectural Testing, Inc. (ATI) was contracted by Pella Windows and Doors to perform tests on two Series/Modal 25, PVC double hung windows. The samples tested successfully met the performance requirements for the following ratings: Test Specimen #1: H -R25 48x72; Test Specimen #2: H R40* 36 x 62. General Note: An asterisk ( *) next to the performance grade indicates that the size tested for optional performance was smaller than the Gateway test size for the product type and class. Test Specification: The test specimens were evaluated in accordance with ANSU A 101/LS2 -97, Voluntary Speci for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. Test Specimen Description: Series/Model: 25 Type: PVC Double Hung Windows Test Specimen #1: H -R25 48 x 72 Overall Size: 3' 11 -1/2" wide by 5' 11 -1/2" high Interior Sash Size: 3' 8-3/4" wide by 2' 11 -1/4" high Exterior Sash Size: 3' 7 -3/4" wide by 2' 10 -1/4" high Screen Size: 3' 7 wide by 5' 8-3/4" high 130 Derry Court York, PA 17402 -9405 phone: 717.764.7700 fax: 717.764.4129 www.arehtest corn 01- 47446.01 • Page 2 of 8 Test Specimen Description: (Continued) Test Specimen #2: H -R 40* 36 x 62 Overall Size: 3' 0" wide by 5' 1 -7/8" high Interior Sash Size: 2' 9-1/4" wide by 2' 6- 7/16" high Exterior Sash Size: 2' 8-1/4" wide by 2' 5-3/8" high Screen Size: 2' 8 -1/4" wide by 4' 11 -1/8" high • The following descriptions app0 to all specimens. Finish: All PVC was white. Glazing Details: All mush utilized 11/16" thick insulating glass fabricated from two shoes of 3/32" thick clear annealed glass and an Intercept" spacer system. The sash were exterior glazed against dual adhesive foam tape and secured with a PVC glazing bead. Weatherstripping: pescription Quantity Location 0.187" backed by 0.250" 1 Row Interior meeting rail, exterior high polypile with center fin meeting rail, bottom rail, top rail, stiles, head and sill upstand 0.187" backed by 0.310" 1 Row Exterior of stiles and exterior of high polypile with center fin bottom rail Fame Construction: The frame was constricted of extruded PVC with mitered and welded corners. Sash Construction: The sash were constructed of extruded PVC with mitered and welded comers. Screen Construction: The screens were constructed of roll formed aluminum with keyed corners. The fiberglass mesh was secured with a flexible vinyl spline. 01-47446.01 Page 3 of 8 .•� Test Specimen Description: (Continued) Hardware: • Description Ouantity motion Plastic tilt latch 4 Interior meeting rail corners and corners of top rail Metal pivot bar 4 Buds of bottom rail and exterior meeting rail Metal cam lock with 1 Midspan of interior meeting rails adjacent keeper Block and tackle 4 Two per jamb balance system Drainage: peseription Ouantity Location 1/4" wide by 1/8" 2 2-1/2" from each end of sill draining high weepslot the exterior sdl hollow 1/4" wide by 1/8" 2 1 -1/2" from each jamb draining high weepslot interior sash pocket 1 -1/4" long by 1/4" 2 One each end of sill draining high weepslot screen track 3/8" wide by 1/4" 4 2-1/2" from each corner in the high weepslot g i g pocket 3/8" wide by 1/8" 8 Two at each end of bottom rail high weepslot draining glazing hollow Reinforcement: Galvanized steel reinforcement was utilized in the exterior meeting rail (Drawing #20 108) and the interior meeting rail (Drawing #20 -109). Installation: Bach window was installed into a #2 Spruce- Pine -Fir wood test buck. The integral nail flange was set against a bed of silicone and secured with #6 x 1 -3/8" screws with 1/4" fender washers located 5" from each end and 8" on center. • 01- 47446.01 Page 4 of 8 Test Results : The results are tabulated as follows: Faragtaph Title of Test - Test Method Results Allow Test Specimen #1: H -R25 48 x72 2.2.1.641 Operating Force 19 lbs max. 301bs max. 2.1.2 Air Infiltration (ASTM E 283 -99) 1.57 psf (25 mph) 0.25 cfm/ft 0.30 cfm/fi max. Note #1: The tested specimen meets the performance levels specified in ANSI/AAIMA WWDA 101/LS 2 -97 for air infiltration. 2.1.3 Water Resistance (ASTM E 547 -00) (with and without screen) WTP a= 2.86 psf No leakage No leakage 2.1.4.1 Uniform Load Deflection (ASTM E 330 -97) (Deflections reported were taken on the exterior meeting rail) (Loads were held for 52 seconds). 15.0 psf (positive) 0.12" See Note #2 15.0 psf (negative) 0.19" See Note #2 2.1.4.1 Uniform Load Deflection (ASTM B 330-97) (Deflections reported were taken on the interior sash stile) (Loads were held for 52 seconds) 15.0 psf (positive) 0.32" See Note #2 15.0 psf (negative) 0.04" See Note #2 Note #2: The Uniform Load Deflection test is not an ANSI /AAMI/NWWDA 101/LS.2 -97 requirement for this product designation. The data is recorded in this report for information only. 2.1.4.2 Uniform Load Structural (ASTM B 330-97) (Permanent Sets reported were taken on the exterior meeting rail) (Loads were held for 10 seconds) 22.5 psf (positive) a0.01" 0.16" max. 22.5 psf (negative) 0.01" 0.16" max. • 01- 47446.01 Page 5 of 8 ,.. Test Results : (Continued) Parasrraph Title of Test - Test Method Bonita owed Test Sbecimen I11: H -R25 48 x 72 (Continued) 2.1.42 Uniform Load Stluctu al (ASTM E 330 -97) (Permanent Sets reported were taken on the interior sash stile) (Loads were held for 10 seconds) 22.5 psf (positive) 0.01" 0.14" max. 22.5 psf (negative) <0.01" 0.14" max. 2.2.1.6.2 Deglazing Test (ASTM B 987 -88) In operating direction at 701bs Exterior top rail 0.11 " /22% 0.50 "I100% Exterior meeting rail 0.10 " /20% 0.50 " /100% Interior meeting rail 0.10 " /20% .0.50 " /100% Interior bottom rail 0.10 " /20% 0.50" /100% In remaining direction at 501bs Exterior left stile 0.08 " /16% 0.50 " /100% Exterior right stile 0.07 " /14% 0.50" /100% Interior right stile 0.08 " /16% 0.50 " /100% Interior left stile 0.09 " /18% 0.50 "/100% 2.1.7 Welded Corner Test Meets as stated Meets as stated 2.1.8 Forced Entry Resistance (ASTM F 588 -97) Type: A Grade: 10 Lock Manipulation Test No entry No entry Test Al through A7 No entry No entry Lock Manipulation Test No entry No entry • 01. 47446.01 Page6of8 Test Results: (Continued) Parana Title of Test - Test Method &MIA Allo Test Specimen #1: H R25 48 x 72 (Continued) Optional Performance 4.3 Water Resistance (ASTM B 547 -00) (with and without screen) WTP .. 5.25 psf No leakage No leakage 4.4.1 Uniform Load Deflection (ASTM B 330-97) (Deflections repotted were taken on the exteriar meeting rail) (Loads were held for 52 seconds) 25.0 psf (positive) 020" See Note #2 25.0 psf (negative) 0.30" See Note #2 4.4.1 Uniform Load Deflection (ASTM 13330-97) (Deflections reported were taken on the interior sash stile) (Loads were held for 52 seconds) 25.0 psf (positive) 0.62" See Note #2 25.0 psf (negative) 0.05" See Note #2 4.4.2 Uniform Load Structural (ASTM B 330 -97) (Permanent Seta reported were taken on the exterior meeting mil) (Loads were held for 10 seconds) 37.5 psf (positive) 0.02" 0.16" max. • 37.5 psf (negative) 0.02" 0.16" max. 4.4.2 Uniform Load Stcactu al (ASTM B 330-97) (Permanent Sets reported were taken on the interior sash stile) (Loads were held for 10 seconds) 37.5 psf (positive) 0.01" 0.14" max. 37.5 psf (negative) <0.01" 0.14" max. • 01. 47446.01 Page 7 of 8 Test Results : (Continued) Paragraph Title of Test - Test Method Rank wed Test Specimen #2: H R40* 36 x 62 Optional Performance 4.3 Water Resistance (ASTM E 547 -00) (with and without screen) WTP = 6.0 psf No leakage No leakage 4.4.1 Uniform Load Deflection (ASTM B 330 -97) (Deflections reported were taken on the exterior meeting rail) • (Loads were held for 52 seconds) 40.0 psf (positive) 0.13" See Note #2 40.0 psf (negative) 0.11" See Note #2 4.4.1 Uniform Load Deflection (ASTM B 330 -97) (Deflections reported were taken on the interior sash stile) (Loads were held for 52 seconds) .� 40.0 psf (positive) 0.58" See Note #2 40.0 pat' (nom) 0.09" See Note #2 4.42 Uniform Load Structural (ASTM B 330 -97) (Permanent Sets reported were taken on the exterior meeting rail) (Loads were held for 10 seconds) 60.0 psf (positive) 0.01" 0.13" max. 60.0 psf (negative) 0.01" 0.13" max. 4.4.2 Uniform Load Structural (ASTM E 330 -97) (Permanent Sets reported were taken on the interior sash stile) (Loads were held for 10 seconds) 60.0 psf (positive) 0.02" 0.12" max. 60.0 psf (negative) 0.01" 0.12" max. • • 01. 47446.01 _ Page 8 of 8 Detailed drawings, representative samples of the test specimen, and a copy of this repo rt will be retained by ATI for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator. This report may not be reproduced, except in fiill, without approval of Architectural Testing. For ARCHITECTURAL TESTING, ]NC: CZ. f , 2 7.-"/ .......rwr rr ,.....w4.....uuw! Eric Westphal Steven M. Urich, P.E. Technician Senior Project Engineer EW:vIm 01-4 7446.01 •.•``1totl?t{Ifflrlr f • i � ;c • ,. .- �SlFic - ' ! •l . ` . ; 11' ..op. Yip DOCUMENT CONTROL ADDENDUM #01- 47446.00 Current Issue Date: 12/15/03 • Report No.: 01- 47446.01 Requested by Todd Umbel, Pella Windows & Doors Purpose: ANSI/AAMA/NWWDA 101/LS,2 -97 testing on a Series/Model 25, vinyl double hung window. Issued Date: 12/15/03 Comments: Certification copy to John Rent at Window & Door Manufacturers Association. Florida Professional Engineer review and seal. rlonda Building Code unhne Page 1 of 2 c ii i ty Affairs BCIS Moms I Log In I Hot Topics Submit Surcharge Stab it Facts ( Publications 1 FBC Staff I BCIS Site Map I Unks f Search 1 I o Product Approval USER: Public user 1u� ri ( „ Aftiir product Anornval Meru > Ergslustgapplimpniparali > Application J > Application Wail FL # FL2309 -R1 Application Type Revision Code Version 2004 r s ! r.r Application Status Approved �--. Comments __ Archived Product Manufacturer Pella Corporation ► - Address / Phone/Email 102 Main St. Pella, IA 50219 �,,1 i (641) 621 -1000 • jahayden ©peila.com Authorized Signature Joseph Hayden jahayden @pella.com _-- Technical Representative Address /Phone/Email ..■ Quality Assurance Representative . Address /Phone /Email --_ Category Windows ._- Subcategory Double Hung Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturers Association Referenced Standard and Year (of Standard) Standard 101/LS.2 -97 ASTM E1300 -02 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A http : / /www.floridabuilding.org/pr /pr app dtl. aspx? param= wGEVXQwtDgv3Pn54vJpohnUx %2f... 4/13/2006 r ionaa tsuilding Code Online Page 2 of 2 Date Submitted 08/05/2005 Date Validated 08/05/2005 Date Pending FBC Approval 08/15/2005 Date Approved 08 /24/2005 Summary of Products FL # Modal Number or Name Description 2309.1 Model 25 Vinyl Double Hung Win 411 -H -654.0 PVC Double Hung Omits of Use (See Other) Approved for use In HVHZ: Certification Agency CnrtMic Approved for use outside HVHZ: Installation Instructions Impact Resistant: PTID 2309 R1 I CCL for Pent' Design Pressure: +/- Verified By: Other: (411 -11- 654.0) - H -R25 (3ft 11 -1 /2in x 5ft 11- 1/21n. Confl • urations of • lass conform to ASTM E1300 -02. 2309.2 Model 25 Vinyl Double Hung Win 411 -H- 654.01 FVC Double Hun. Omits of Use (See Other) Approved for use in HVHZ: Certification stals Agency Cartifle Approved for use outside HVHZ: Installation Instructions Impact Resistant: Verified By: Design Pressure: +/- Other: (411 -H- 654.01) H -R40 (3ft Oin x 5ft 1- 7/81n. Configurations of • lass conform to ASTM E1300 -02. 2309.3 Model 25 Vinyl Double Hung Win 411 -11-658.0 PVC Double Hung Omits of Use (See Other) Certification Agency Certiflc Approved for use in HVHZ: Installation Instructions Approved for use outside HVHZ: Verified By: Impact Resistant: Design Pressure: +/- Other: (411 -H- 658.0) H -R30 (4ft Oin x 6ft 61n).Conflgurations of glass conform to ASTM E1300 -02. lack I I Next I DCA Adminlstrarlpn Dap.,tm nt of Communlly Affairs Florida building Code Online Codes end Standards 2555 Shunard Oak Boulevard Tallahassee, Florida 32399 -2100 (850) 487 -1824, Suncom 277 -1824, Fax (850) 414 -8436 O 2000 -2005 The State of Florida. All rights reserved. Coovrlaht and Disclaimer Product Approval Accepter 1111111 . • http : / /www.floridabuilding.org/pr /pr app dtl. aspx? param= wGEVXQwtDgv3Pn54vJpohnUx %2f... 4/13/2006 ®Pella Cor • oration 2005 Part Number: V782588 1MNsM!! ' 1I �, i glom Illustrations s own are for a Double -Hung Window product. The steps are the same as the Single - hung, Sliding, Fixed, Casement, and Awning units. Notes are provided at steps where the information is not the same for all products. Installation Instructions for Typical Wood Frame Construction. These instructions were developed and tested for use with typical wood frame wall construction in a wall system designed to manage water. These instructions are not to be used with any other construction method. Installation instructions for use with other construction methods may be obtained from Pella Corporation, a local Pella retailer, or by visiting bttp : / /wunatbermaatarbypella,com. Building designs, construction methods, building materials, and site conditions unique to your project may require an installation method different from these instructions and additional care. Determining the appropriate installation method is the responsibility of you, your architect, or construction professional. Handling and Storage: Provide full support under the framework while storing, moving and installing the product. DO NOT lift the product by the head member only. Remove the plastic shipping material prior to storing or installing the product. DO NOT store in direct sunlight. Allow sufficient spacing between products for ventilation. YOU WILL NEED TO SUPPLY: TOOLS REQUIRED: • Cedar shims /spacers (12 to 20) 4011 1.14r • Tape measure • 2" galvanized roofing nails (1/4 lb.) ..s • Level . _ _ _ • Closed: cell foam backer rod/sealant backer (12 to 30 ft.) \ • Square I. • Pella. SmartFlash'a' foil backed butyl window and door • Hammer flashing tape or equivalent • Stapler aii • Great Stuff TM Window and Door Insulating Foam Sealant 81 • Scissors or utility knife maw by the Dow Chemical Company or equivalent low pressure • Small flat blade screwdriver polyurethane window and door foam - DO NOT use high pressure or latex foams. • High quality exterior grade polyurethane or C Installation will require (2) or silicone sealant (1 tube per window) more persons for safety reasons. REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT. Pin g'Window Top t } 4. Corner Tape ng � _ _ I' i . Com �VV i tit$ Tape Top •E t l r Ta Si h I •. de hi Phun 1 1 Tape 1l I11 – f ° Si – - - Cheduai� F �hmg l _ -,, L' – 1 Window Sotto - / Sill Plathing Tape dl �'°" Sill Plashing Tape N2 <, 4' Weather Rdirtive Barrier — Sheathing i �� , Framing °++-"a"':Uri Always read the ThermaStar by PellaTM Limited Warranty before purchasing or installing ThermaStar by Pella products. By installing this product,: you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance instructions may void your Pella limited warranty See Limited Warranty for complete details at bttp: / /warranty.thermastar.com, � ROUGH OPENING PREPARATION A. Verify the opening is plumb, level and square. Ensure the bottom of the rough opening does not slope toward the interior. I '� Note: Do not install in out-of-square opening or on a surface that is not level ' lA 1 B. Verify the window will fit the opening. Measure all four sides t of the opening to make sure it is 1/2" larger than the window in both width and height. On larger openings measure the width and height in several places to ensure the header or studs are not L= bowed. — - a Note: 1 -1/2" or more of solid wood blocking is required around t h e p e r i m e t e r o f t h e o p e n i n g . F i x a n y p r o b le m s w i t h t h e r o u g h : -* opening bafivre proceeding. ,�, iB 23 C. Cut the weather resistive barrier (1C). Weatbet ltcsistive Barrier Nk.„ �Isrcut 'M ir e 4th cut: ;-• aid cut Make a 6" cut up from each top corner at a 45 angle to allow the weather Y-----.... � .4s7 ; • .ti barrier to be lapped over q.` it y - 45. ,.. the fin at the head of the ' �, 'S In , window. -1:;;.---.. - ' - - - - - d ;y -2nd' �� i ` cut 1 D. Fold the weather resistive barrier (1D). Fold side and bottom flaps into the opening and staple to inside wall. Fold top flap up and temporarily fasten with flashing tape. 1 D E. Apply sill flashing tape #1. Cut a piece of flashing tape 12" longer - _ _ -_ than the opening width. Apply at the bottom of the opening as " - - ----- _ _ , shown (1 E) so it overhangs 1" to the exterior. 1" Note: The tape is cut 12 longer than the width so that it will extend 6" up each side of the opening. e ; 11 i 49 a F. Tab the sill flashing tape and fold Cut 1" wide tabs at each corner „` (1/2" from each side of corner) (1F). Fold tape to the exterior and press firmly to adhere it to the weather resistive barrier. ;/ G. Apply sill flashing tape #2. Cut a piece of flashing tape 12" longer , PP g tape than the opening width. Apply at the bottom, overla in e #1 by at least 1 ". Do not allow the tape to extend past the interior face a ` ± "` of the framing (1G). y , Note: The /lathing tape does not need to extend all the way to the !1; 4. interior of the framing. H. Install and level sill. Place 1" wide by 1/4" thick shims on the bottom of the window opening, 1/2" from each side, beneath transition bars, mullion joints and sliding window interlockers. Place an additional 1" wide by 1/4" thick shims, ensuring that the distance between shims is not more than 18" on center. Adjust shims as necessary to ensure the silt is level. � �, 1 H Note: To determine the depth of the shim, measure the distance I � li t... from the back of the fin to the interior frame edge and cut the r, e shim to this dimension. Place the exterior edge of the shim flush ' with the exterior of the building. Improper placement of shims may result in bowing the bottom of the window. 2 SETTING AND FASTENING THE WINDOW A. Remove packaging from window. DO NOT open the window until it is fully fastened. Inspect the unit for any crack or penetration in the frame. DO NOT install damaged units. TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS. B. Insert the window from the exterior of the building. Place . the bottom of the window on the spacer at the bottom of the opening, then tilt the top into position. Center the window 2B ' - -, between the sides of the opening to allow clearance for _ corner on each end of the top nailing in the first hole from the , ling fin. These are used to hold f shimming, and insert one roofing the window in place while shimming it plumb and square. IM i Note: DO NOT drive the nail all the way in. TA C. Plumb and square window. Place shims 1" from the bottom and top of the window between the 1 window and the sides of the opening. Adjust Interior View the shims as required to plumb and square the - - '� ° j window in the opening. �I d 2C Casement, Fixed & Sliding: If the frame height exceeds 47 ", place shims at the midpoint of the window sides. r Double and S - hung: Be sure to shim at the checkrail. If the frame height exceeds 47 ", place additional shims midway between the checkrail shims and both the top and bottom 1 I I .e shims. ii D. Fasten the window to opening by driving 2" VIM galvanized roofing nails into every other pre - punched hole in the nailing fin. Drive nails until the head contacts the . .... fin, however do not sink the head. This allows for movement of building .`e„,,;,- - - materials. DP 50: Insert #8 x 2" pan head stainless steel wood screws with flat 1 washers into every pre - punched hole in the nailing fin. Drive screws until ` the head/washer contacts the fin, however do not sink the washer. This allows for movement of building material. 1 s 2D E. Check window operation (vent units only). Open and close the window ` �' a few times to check for proper operation. Close and lock the window. Double and Single-hung: Make sure the window will tilt correctly. Note: If there are any problem with the operation of the windowr, recheck shim locations and adjust for plumb and square. 3 INTEGRATING THE WINDOW TO THE WEATHER RESISTIVE BARRIER A. Apply side flashing tape. Cut 2 pieces of flashing tape 4" longer than .-� ti frame height of the window. Apply one piece to each side over ., ' ' - - the nailing fin and onto the weather resistive barrier. The tape should '° �„ extend 2" above the top of the window and 2" below the bottom �� of the window. Press the tape down firmly. !i B. Apply top flashing tape. Cut a piece of flashing tape long enough to — \ go across the top of the window and extend at least 1" past the side flashing tape on both sides. Apply the tape over the top nailing fin as shown. Press the tape down firmly. P g =\ tape or seal the bottom nailingfin. -�.. I Note: DO NOT ,m _____,,,L...............,.. p C. Fold down top flap of weather resistive barrier (3C). D. Apply flashing tape to diagonal cuts. Cut pieces ' - of flashing tape at least 1" longer than the diagonal cuts in the A - . - - weather resistive barrier. Apply the tape, covering the entire 1 - ........ diagonal cut in the weather resistive barrier at both upper corners : I de of the window. Press the tape down firmly. I �� Note: Be sure to overlap th t corners (3D). 3D �i`; , 5 f" I I ;� 4 INTERIOR SEAL - f Caution: Ensure use allow pressure po*notbane window and door insulating foams and strictly ollow the foam manufacturers r commendations for application. Use of b:gh pressure foams or improper application of the fians may cause the window frame to bow and hinder operation. A. Apply insulating foam sealant. From the interior, insert the nozzle of the applicator approximately 1" deep into the space between the window and the rough opening and apply a 1" deep bead of foam. This will allow room for expansion of the foam and will minimize squeeze out. For windows with jamb extensions installed, ensure the foam is placed between the All window frame and the rough opening, not between the jamb ff ,, 111 . 10 extension and the rough opening. If using insulating foam Interior,- p other than Great Stufm Window and Door Insulation T' Foam by the Dow Chemical Company, allow the foam to 0044 ' cure completely (usually 8 to 24 hours) before proceeding to ,, the next step. Q Note: It may be necessary to squeeze the end of the tubs with pliers to be able to insert into the space between the window frame and the ►ugh opening. DO NOT complete .P the space from the back of then to the interior the wi f o ndou+c ' B. Check window operation by opening and dosing the window. Notes: If the window does not operat comedy, check to make sure it is still plumb, level square and that the sides are not bowed If adjustments are requirn4 remove the Amps with a serrated knifie. Adjust the shims, and reapply the insulating foam sealant: 5 SEALING THE WINDOW TO THE EXTERIOR WALL CLADDING Note: The Vinyl/Steel siding detail below applies to windows that do not have al as part of theframe. For windows that have J - mould as part of the frame, this s t e p should be omitteai When suing windows that have J -mould as part ofthe fivane in masonry or with wood sidin g, the the J-mould must be removed from the fame, and the backer rod sealant must be applied as shown in Li I and rl - — •• mime ryrioi twine _ •. r' • . 'R.. Ned aid , clue typical .. , :: { .. n. rice rypkJ sad sell 110 Ili -la 112• ilf• ....... -.. ham f'dni.•. A. Insert closed cell foam backer rod into the space around the window as deep as it will go. This should provide at least a 1 / 2 " clearance between the backer rod and the exterior face of the window. Note: Backer rod adds shape and depth for the sealant line. 4 III B. Apply a bead of high quality exterior grade sealant to the entire perimeter of the window. Note: Refer to the sealant =- manu label to verify compatibility with vinyl and the `10' SB E adjoining building components and priming requirements. C. Shape, tool and clean excess sealant. When finished, the sealant should be the shape of an hourglass. I Note: This method creates a more fhtxible sealant line •� capable of expands'ng and contracting. , I CLEANING INSTRUCTIONS Remove labels and clean the glass, using a soft, clean, grit -free cloth and mild soap or detergent. Be sure to remove all liquid by wiping dry or use a clean squeegee. The vinyl frame may be cleaned as described above. For stubborn dirt, a "non - abrasive" cleaner such as Bon -Ami® or Soft Scrub® may be used. Do not use solvents such as mineral spirits, toluene, xylene, naphtha or muriatic acid as they can dull the finish, soften the vinyl and/or cause failure of the insulated unit seal. Keep door tracks clear of dirt and debris. Keep weep holes open and clear of obstructions. IMPORTANT NOTICE Because all construction must anticipate some water infiltration, it is important that the wall system be designed and constructed to properly manage moisture. Pella Corporation is not responsible for claims or damages caused by anticipated and unanticipated water infiltration; deficiencies in building design, construction and maintenance; failure to install Pella products in accordance with Pellas installation instructions; or the use of Pella products in wall systems which do not allow for proper management of moisture within the wall systems. The determination of the suitability of all building components, including the use of Pella products, as well as the design and installation of allow for proper management of moisture within the wall systems. The determination of the suitability of all building components, including the use of Pella products, as well as the design and installation of flashing and sealing systems are the responsibility of the Buyer or User, the architect, contractor, installer, or other construction professional and are not the responsibility of Pella. Pella products should not be used in barrier wall systems which do not allow for proper management of moisture within the wall systems, such as barrier Exterior Insulation and Finish Systems, (EIFS) (also known as synthetic stucco) or other non -water managed systems. Except in the states of California, New Mexico, Arizona, Nevada, Utah, and Colorado, Pella makes no warranty of any kind on and assumes no responsibility for Pella windows and doors installed in barrier wall systems. In the states listed above, the installation of Pella Products in barrier wall or similar systems must be in accordance with Pella's installation instructions. Product modifications that are not approved by Pella Corporation will void the Limited Warranty.