Loading...
Permit Mech 2010 MS CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 10-00001099 Date 9/03/10 Property Address . . . . . . 400 GARDEN LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 3 ton HVAC system change out ------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PERSICO CYNTHIA ET AL WAYCHOFFS AIR CONDITIONING 400 GARDEN LANE 6929 PHILLIPS PARKWAY DR S ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256 (904) 838-9052 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . ARI 3647405 3 TON CHANGE OUT Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/02/11 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 O /0 .TOB ADDRESS: TLJO "( d-P"tl LLiu PERMIT# PROJECT VALUE $ G-7 ) I ° NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3 4-1gpG Air Conditioning: Unit Quantity (_ Tons Per Unit REQUIRED Heat: Unit Quantity I BTU's Per Unit ,g Lv-O O Seer Rating S -10 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Yl `I" -I'd S e4 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ✓ Phone Number S Mechanical Company C� ,V �it A Q, Office Phone g q bS Fax agQ- -7 Co. Address: 1,tAkS r . S City VA 61r'SW V 11(-0 State'— Zip License;3older (Print): tate ication/Registration#CAG 113"1 Notarized,Signature of Lzcente Holder �Yn vEpNAcEANFFvw�iMPTON Sworn and subscribed be re me this 3� day of �2rD ha� 201�j MY COt�tdItSS10N#DD627785 —� WIRES:JAN 08,2011 Signature of Notary Public Sandia thfaugh tst State Insurance I. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17,2009 and Dec 31,2010. Certificate of Product Ratings AHRI Certified Reference Number: 3647405 Date: 9/3/2010 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 215BNA036****A Indoor Unit Model Number: FX4DN(B,F)043 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY 15 PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240.2006 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34800 EER Rating(Cooling): 12.50 SEER Rating(Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 34200 Region IV HSPF Rating(Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 21600 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS.which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, 6 the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at - - �- click on" "link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2010 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129280051083792983