Permit 1931 Francis Ave JOB ADDREW r`?., 0 ,2&,77 /1 TYPE WORK Xa7y�
PROPERTY O C� / ` .� TM EPHOAE /-/ Z 2 2
COATRACTOR � � TEL FPEONE
PERWT N UMBER_ao3o g DATE 2 3-0
INSPECTIONS.- FOOTING
rye. 6&rriu Qs ,SLAB
TTEBE"
LLVTEL
NAILING MM
�o� FRAMING/COVER GP ` t4'—?fid
IIVSDLA1I0N
FINAL BUILDING
CER=CA.TE OF OCCUPANCY
ELEcnuc4L PE smv
lNSPECITONS ROUGE 9 1U
FINAL Cl
A&CHA1VICAL PER11:fM ao 932-
IVSPECITONS ROUGE
FINAL
PLUMB VG PF.VhlM �Z o 4 6-7 —
IZVSPEC 7ONS ROUGUANDER SL4 B
TOPOUT
WA�E3YER
FINAL
NOTES: e�- /C o u� J 2v _z 7 z
CITY OF ATLANTIC BEACH
CERTIFICATE OF OCCUPANCY
This Certificate issued pursuant to the requirements of Section 146 of the Standard Building Code certifying that at the time of issuance this structure was in
compliance with the various ordinances of the City regulating building construction or use. For the following:
Address: 1931 FRANCIS AVENUE Owner: BEACHES HABITAT
ATLANTIC BEACH, FL 32233 P. O. BOX 50939
JACKSONVILLE BEACH, FL 32240
Construction Type: WOOD FRAME
Use Classification: SINGLE FAMILY
Permit Number: 20309
Date: 4/3012001
rte----
DON C. FORD, C.B.O.
Post in a conspicuous apace
CITY OF ATLANTIC BEACH
DEPARTMENT OF BUILDING
800 Seminole Road -Atlantic Beach, FL 32233-Tel: 247-5826-Fax: 247-5877
ELECTRICAL PERMIT
y PERNItT NP MM
.�.r,f .L4C` `TI `�iINF:ORM/ u.0
Permit Number: 20651 Address: 1931 FRANCIS AVENUE
Permit Type: ELECTRICAL ATLANTIC BEACH, FL 32233
Class of Work: NEW Township: Range: Book:
Proposed Use: SINGLE FAMILY Lot(s):3 Block: Section:
Square Feet: Subdivision: FRANCIS COVE
Est. Value: Parcel Number:
Improv. Cost: .: Cf1AMERfr1NFkS
Date Issued: 9/19/2000 rName: BEACHES HABITAT
Total Fees: 45.00 Address: P. O. BOX 50939
Amount Paid: 45.00 JACKSONVILLE BEACH, FL 32240
Date Paid: 9/19/2000 Phone: (904)241-1222
Work Desc: CS2/0 150AMPS 1 PH 3W 240V CABLERW ALUM NEW RESIDENTIAL SERVICE
. . �. R �-
CMA ELECTRICAL CONTRACTOTS`OF FL PERMIT 45.00
t ns actions Re q"u�red o.
ROUGH ELECTRIC FINAL ELECTRIC
NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION
BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND
MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER
"FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY
OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"
ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION
FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
I
$45.00 14
�- - CHECKS 9/20/00 01 Receipt: 0590429
2562
AT TIC BEA BUILDING DEPT. 00100003221000
CITY OF
800 SEMINOLE ROAD
r ATLANTIC BEACH, FLORIDA 32233-5445
TELEPHONE (904) 247-5300
FAX (904) 247-5805
SUNCOM 352-5800
DATE ZI
JEA Construction & Maintenance
2325 Emerson Street
Jacksonville, FL 32207
Attention: Connie
Re: Final Electrical Inspections
Dear Connie:
Final Inspections on the following locations have been completed and approved:
PERMIT NO. ADDRESS
Please call me at 904-247-5826 if you have any questions.
Sincerely,
ATLA B ACH BUILDING DEPARTMENT
't
CITY OF ATLANTIC BEACH '
APPLICATION FOR PLUMBING PERMIT
JOB LOCATION . S Ry '—
:OWNER OF PROPERTY : t J:FJ4 Cµit, S 114A 1 7-4 f '1
PLUMBING CONTRACTOR Q e G Kulvxn'n16
CONTRACTOR' S ADDRESS : 1%< 14 44.✓a
STATE LICENSE NUMBER: G1�c a 11693 TELEPHONE :
HOW MANX OF THE FOLLOWING FIXTURES INSTALLED
SINKS SHOWERS
Z
LAVATORY ' WATER HEATERS `I
z
DISHWASHERS- BATH TUBS
URINALS ___ DISPOSALS
Z CLOSETS WASHING MACHINE
FLOOR DRAINS SHOWER PANS
OTHER
TOTAL, FIXTURES : SI5 . 00 1-13.
miNIMUM PERMIT FEE - $25 . 00
SIGNATURE OF OWNER:
SIGNATURE OF CONTRACTOR:
-------------------------------- ------------------------- --------
INSTALLATION OF -PLUMBING, AND FIXTURES MUST BE IN ACCORDANCE WITH It
THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. '+�
CALL A DAY AHEAD TO SCHEDULE INSPECTIONS
- ( 904 ) 247 -5826
• SEWER CONNECTIONS MUST BL•' CALLEI) INTO PUBLIC WORKS FOR INSPECTION
PRIOR TO COVERING UP 24'1 - 5634
y�
i,.
CITY OF ATLANTIC BEACH
DEPARTMENT OF BUILDING
800 Seminole Road -Atlantic Beach, FL 32233 -Tel: 247-5826 - Fax: 247-5877
PLUMBING PERMIT
Permit Number: 20467 Address: 1 FRANCIS AVENUE
Permit Type: PLUMBING ATLANTIC BEACH, FL 32233
Class of Work: NEW Township: Range: Book:
Proposed Use: SINGLE FAMILY Lot(s):2 Block: Section:
Square Feet: Subdivision: FRANCIS COVE
Est. Value: Parcel Number: FRANCIS COVE
Improv. Cost:
Date Issued: 8/09/2000 Name: BEACHES HABITAT
Total Fees: 43.00 Address: P. O. BOX 50939
Amount Paid: 43.00 JACKSONVILLE BEACH, FL 32240
Date Paid: 8/09/2000 Phone: (904)241-1222
Work Desc: INSTALL PLUMBING IN NEW HOME
r
B &G PLUMBING PERMIT 43.00
UNDERSLABPLUMBING SEWER WATER TOPOUT
FINAL
NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION
BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC
SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER
"FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY
OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"
ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION
FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
$43.88 14
, Date: 8/89/88 81 Receipt: 8879155
CHECKS 18269
ATLA TIC BEACH EIUILDING DEPT. 88188883221888
CITY OF
4&4a&' 3emA-/f
Office of Building Official
REQUEST FOR INSPECTION
Date V r / y Permit No. o
Time .M•
Received P
A Mil
/ C
Job Address Locality
ContTsr
BUIL ING NCHETE ELECTRICAL PLUMBING MECHANICAL
Framing ❑ ❑ Rough Wiring ❑ Rough ❑ Air Cond. & ❑
Re Roofing ❑ Slab Temp Pole ❑ Top Out Cl Heating
Insulation ❑ Lintel Final ❑ Sewer ❑ Fire Place ❑
Pre Fab
READY F011 INSPECTION M
Mon. J
GO
Thurs. Friday _
�,—•� A.M.
Inspection Made P.M.
Inspector / Final Inspection ❑
Certificate of Occupancy ❑
Date
CITY OF ATLANTIC BEACH
DEPARTMENT OF BUILDING
800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 2.47-5877
PERMIT INFORMATION _ LOCATION INFORMATION
Permit Nurrrber: -20309 _
I � Address: 1931 FRANCIS AVENUE
Permit Type: BUILDING ATLANTIC BEACH, FL 32233
Class of Work: NEW Township: Range: Book:
Proposed Use: F``-I E FAMILY Lot(s):;?, Block: Section:
tl Square Feet: I Subdivision: FRANCIS COVE I
Est.Value- Parcel Number:
Improv. Cost: 1
OWNER INFORMATION
Date Issued: "Ame: BEACHES HABITAT -
Tota! Fees: c/T n. BOX 50939
Amount Pair '4� Y OF """ LE BEACH, FL 32240
Date Pair Date Office s_
Work Deg Time � REQV of @4i/an
-_ -
�.—_ Receiveq -- EST FOR � g Of0/Cla/
FP—RkO—PEkTY-( NSPEC O.OQ -_-�
T/ON
Note: Jo c3 P.M. 350.00
1 b
250.00
�Wn s Addre _ P reit �
Hamer, ss er No 520 5.21
Framing �,
C 0.27
ttsu/,Root.
1- �NCgET locati 325.Q0
0 Slab ng E ESE Contractor �' ty 35.00
Mon Lintel � Roug hR/Cq� 1,164.00
O Tem Wining PI.I/ 5.33
I
Final
na p Pole � R MBING
ou 0.59
Inspection Tues. REA p 0 D Top o ME Hq #
Inspectorn Made Y F R/ P Sewer ut Air o N/cA�
— Wed Ng FCT/pN Meati 0d g
Ire
�TRE� P e ACe
Pb
COVER ur �` �J M Friday i
A.M j
j CERTIF/OCCUPAP4 ., �Z Final toSPM.
I Certitlcate pectipn 0
f
I
Date of occupancy G
NOTICE-INSPECTIONS MUST BE REQUESTED AT LEAST c-. . 3PECTION
- -- — -- — — _ - -- --- — C --- - - 1
BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED►,. . UBLIC SPACE,AND
MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER I
.. _ 1
"FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY
I OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"
ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION
FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
1
, Operator: CHERYLE
C ___.____._._ Date: 8130/00 01 Receipt; 0084847
NTIC BEACH BUILDING DEPT. Total Payment $3660.40
CITY OF ATLANTIC BEACH, FLORIDA jr,
- by APPLICATION FOR ELECTRICAL PERMIT
r,
TO THE CHIEF ELECTRICAL INSPECTOR: DATE:
IMPORTANT NOTICE:
IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE
HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS,
WHICH ARE A PART HEREOF,AND IN'ACCORDANCE THE ELECTRICAL REGULATIONS, CODES AND CITY OF
ATLANTIC BEACH ORDINANCES.
ELECTRICAL FIRM: M IIC'IAN SIGNATURE JOURI
NAM4 P � ADDRESS: Z 1. t 5 5I RFO BOX
BLDG.SIZE BETWEEN: L� QAJ►y SIL (IZ
RES(YI' APT.( ) COMM.( ? PUBLIC( I INDUS.( ) NEW YET OLD( 1 REW.( 1
ADDITION( I TRAILER( ) TEMP.( ) SIGNS ( ) SQ.FT.
SERVICE: NEW(INCREASE( ) REPAIR( ) ' FEE
CONDUCTOR SIZE O AMPS 1:5 Q COPPER g ALUM.I'T—
SWITCH OR BREAKER �� AMPS PH > W Zt</OLT A (/*ACEWAY
EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY
FEEDERS NO. SIZE NO. SIZE NO. SIZE
LIGHTING OUTLETS CONCEALED OPEN TOTAL
RECEPTACLES CONCEALED OPEN TOTAL
0.30 AMPS. JS•f00 AMAB.
SWITCHES
INCANDESCENT
FLUORESCENT&M.V.
FIXED 2.100 AM". ovsn
APPLIANCES BELL TRANSF.
AIR MY.RATING H.P.RATING
CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT
0-IOVER
MOTORS H.P. 11 VOLTAGE I PHS NO. I H.P. VOLTAGE PHS
MISCELLANEOUS
D(J
TRANSFORMERS: UNDER 600 V. OVER 600 V.
NO. I KVA NO. KVA
NO.NEON TRANSF. N0. VA. MA. MOTOR SIZE I SWITCH FLASHES:
EACH SIGN
FORWARDED
s
TOTAL FEES
CITY 4 O
800 SEMINOLE ROAD
ATLANTIC BEACH, FLORIDA 32233-5445
-- TELEPHONE(904)247-5800
-- �^ FAX (904)247-5805
.--------�V t�� SUNC()M 8`"-.-5800
DATE
JEA Construction & Maintenance
2325 Emerson Street
Jacksonville, FL 32207
Attention: Connie
Re: Rough Electrical Inspections
Dear Connie:
Rough inspections on the following locations have been completed and
approved:
PERMIT NO. ADDRESS
Please call me at 904-247-5826 if you have any questions.
Sincerely,
ATLANTIC BEACH BUILDING DEPARTMENT
Boob 9649 Page 237
This,ins as pre aced byoc .2(�tl►t13t7►131
Page: 237
P.O.Box 50939 Filed & Recorded
Jacksonville Beach,Florida 32240 06/09!00 01:52:81 PM
CCL RK CIRCUIT COURT
5 MIN.^ R U DUVAL COUNTY
TRUST F00
PHONE # �' NOTICE OF,COMMENCEMENT RECORDINGD $ 5.
STATE OF FLORIDA Permit No.:
COUNTY OF DUVAL Tax Folio No.:
The undersigned hereby gives notice that improvements will be made to certain real property,and
in accordance with section 713,Florida Statutes,the following information is provided in this Notice of
Commencement.
1. Dnscription of property:(le al description of property and street address ifavailable)
�
2. General description of improvements: To build a single family residence
3. Owner Information:
a. Name and Address: Habitat For Humanity Of The Jacksonville Beaches,Inc.
P.O.Box 50939,Jacksonville Beach,FL 32240
b. Owner's interest in the site of the improvements: 100%
C. Name and Address of fee simple title holder(if other than owner) :N/A
4. Contractor: l—
a. Name and Address: c�c� C' uv��r)'L c� 01-
., b. Phone Number: j04—�44
C. Fax Numben(optional, if service by fax is acceptable)
C>?
` i-(-1 -L}- 1 1�
5. Surety on any payment bond: NONE
6. Name of any lender making a loan for the construction of the improvements: N/A
7. Persons within the State,of Florida designated by owner upon whom notices may be served as
provided by Section 713.13(1) (a)7,Florida Statutes:
Praullt- P.O.Box 50939,Jacksonville Beach,FL 32240,
Phone: (904)241-1222
Facsimile: (904).241-4310
8. In addition to himself, owner designates the following person to receive a copy of the lienor's
notice as provided in Section 713.13 (1)(b),Florida Statute(Name,Bank and Address): N/A
9. Expiration date of notice of commencement: 1 year from the date of recording.
Thefore oingins rwnentwasacknowledgedbefore HABITAT FOR HUMANITY OF THE
me this day of 2000 byJACKSONVILLE BEACHES,INC.
(�c12K/ti9-le ,who [ s personal y known to me or
r 1 u- .x._,.,7......,7 ,._ :.]-_i:�--`=-- ^--- S'�61✓�_
A00's".
BUILDING AND ZONING INSPECTION DIVISION
CITY OF ATLANTIC BEACH
ATLANTIC 11"",FLORIDA 31133
APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER
IMPORTANT—Applicant to complete all items in sections I, 11, III, and IV.
1, Sheat Address: 1q31
LOCATION �/�
OF laterseefing Streets: Sefrreen 0V/ / And 3 C1NA) r
BUILDING
Sob-division
11. IDENTIFICATION—To be completed by all applicants.
In consideration of permit given for doing the work as described in the above statement we hereby agree to perform said work in accorrlenu
with theof echrd plans and specifications which are a part here*(and in accordance with the City of Jacksonville ordinances and standards
of good.practice listed therein.
Nano of Meehaskol / Contractors
Contractor 1►rint) .G_CNwa, y s'rA Mader
Name
per/y Owner
Signature of Owner 9 of
or Authorked Agesf a ee r
11. GWRAL INFO
Type of hoofing fed: DING OR SITE1 8'
CONSTRUCTION BEING e'7,ON�
a V rnrrsryrV
❑ 6u- ❑ N.Nn Cl Control Utility
IF YES, GIVE NOMI! g$gU 'ION
13 Oil PERMIT G�
❑ Other—Specify
1V, ktIECNANMAL EQUIPMWT TO EE IN11TAUM NATURE OF WORK
(Provide complete list of components an back of thio fern) 10' Residential or ❑ Commercial
Nest ❑ Spee ❑ Recessed 'zi—Ceefol 0 Floor New Building
❑��Nr Ccs Is Ing: (3 Room Genfnl / ,f, I/ CI Existing Building
/�DeN Syefew: Meforfel r1 ' Thkk / ? ❑ Replacement of existing system
Mnimum capacity SA-QN—sw Installation(No system previously Installers
❑ Extension or add-on to existing system
❑ Reff4—tw4 ❑ Other—Specify
❑ Cosillq Mer:Capacity 94
❑ Are strf t"s Number of hoed,
(3 Ekwter Q MoeRfl ❑ Eeufatw (neolbar) THIS SPACE POR OFFICE USE ONLY
❑.GoeepM pe111,•• —jawasborl
Q,•Tuk,_. Inamber) Remarks
❑ IPC rxusb (number)
❑ Usfired preewes,vessel
Permit Approved by Data
—
13 Belk"
Q Other—'Specify Permit Fee
L18T ALL RQUIPMENT
AIR coNDl'ilwk;AND REFRIGERATION EQUIPMENT ppaacctI yp �
tree Veli. DUGAptlon modal Number Manufacturer �('faaajy Awloeay
O G a
MUTING•FURNACES,BOILERS,FIREPLACES Capacity
NUtabortfulta Ussedptt— ]t bee, Y ufaoWrer (NM A=
NI' al
T
TANKS
NOW many Newlin" Capacity Name of
serial Approving
sed Dkmm lona i .qu1t
Nanmfaeturl r No. ngmcy
CITY OF ATLANTIC BEACH
DEPARTMENT OF BUILDING
800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233—TEL: 247-5826—.FAX: 247-5877
rs•'
Permit Number: 20273 Address: 1941' FRANCIS AVENUE
Permit Type: TREE REMOVAL ATLANTIC BEACH, FL 32233
Class of Work: NEW Township: Range: Book:
Proposed Use: SINGLE FAMILY Lot(s):2 Block: Section:
Square Feet: Subdivision: FRANCIS COVE
Est. Value: Parcel Number: FRANCIS COVE
Improv. Cost: RUVINAMEM
Date Issued: 6/23/2000 Name: BEACHES HABITAT
Total Fees: Address: P. O. BOX 50939
Amount Paid: JACKSONVILLE BEACH, FL 32240
Date Paid: Phone: (904)241-1222
Work Desc: TREE REMOVAL FOR LOT 2, FRANCIS COVE
PROPERTY OWNER
NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION
BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND
MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER
"FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY
OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"
ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION
FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
A TIC B-6kCIA BUILDING PT.
CITY OF ATLANTIC BEACH
DEPARTMENT OF BUILDING
800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877
Permit Number: 20272 Address: 1941 FRANCIS AVENUE
Permit Type: FOUNDATION ONLY ATLANTIC BEACH, FL 32233
Class of Work: NEW Township: Range: Book:
Proposed Use: SINGLE FAMILY Lot(s):2 Block: Section:
Square Feet: Subdivision: FRANCIS COVE
Est. Value: Parcel Number: FRANCIS COVE
Improv. Cost:
Date Issued: 6/23/2000 Name: BEACHES HABITAT
Total Fees: Address: P. O. BOX 50939
Amount Paid: JACKSONVILLE BEACH, FL 32240
Date Paid: Phone: 904)241-1222
Work Desc: FOUNDATION PERMIT FOR LOT 2, FRANCIS COVE
PROPERTY OWNER
TREE BARRICADES FOOTING SLAB
NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION
BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND
MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER
FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY
OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"
ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION
FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW.
C�
ATLANTIC BEAC BUILDI EPT.
CITY OF ATLANTIC BEACH
TREE REMOVAL APPLICATION
All applications must submitted with seven(7) copies and received by 5 PM on Friday ten(10)
days prior to the scheduled meeting,in order to be placed on the agenda. * INCOMPLETE
APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE
PROCESSED.
ll r fi�f ;� 4. 3�, 5'c,232 PIX s.+ 4-(-""
l 1
d
APPLICANT NAME ADD SS TELEPHONE
2 �' i�1 1 Y �-` �-
ADDRES9 OR LEGAL DESCRIPTION OF TREE REMOVAL SITE
3. REASON FOR PROPOSED TREE REMOVAL:
i
Hc ti f-
4. HAS THIS SITE BEEN TO THE TREE BOARD BEFORE? ❑YES )1 NO ❑ NOT SURE
5. PROPERTY ZONING: ;R RESIDENTIAL ❑ COMMERCIAL
6. LIST TREES PROPOSED FOR REMOVAL:
INTERIOR OR
SPECIES DIAMETER * EXTERIOR ZONE**
14 CA ew IL y 611
Z
*Diameter at Breast Height(D.B.H.)is measured at 4.5 feet above grade. To accurately determine
diameter,measure the trunk circumference and divide by 3.14. Diameter of multi-trunked trees is
determined by adding together the diameter of each trunk as measured immediately above the
forks.
7. SITE PLAN/TREE SURVEY indicating:
a) Changes of topographic features such as hills and low areas affecting trees.
b) Existing and proposed structures.
c) Location of all trees with Diameter at Breast Height (DBH) of six inches or more.
d) Tree species and sizes in DBH.
e) Trees to be removed should be clearly marked with an"X".
f) Trees to be preserved on-site for mitigation must be marked with brackets
g) Location, size and species of any proposed new replacement trees marked with a
circle"O".
h) Location of utilities and easements as applicable.
i) Location of trees to be preserved on-site with barricading indicated.
8. ON-SITE REQUIREMENTS:
a) All trees identified for removal MUST be marked on-site by RED flagging,
paint or tape.
b) All trees to be preserved on-site for mitigation MUST be marked with BLUE
flagging,paint or tape.
C) The front property corners must be marked by stakes or paint indicating the Lot
Number or Address.
9. * INCOMPLETE APPLICATIONS OR INACCURATELY MARKED SITES
WILL NOT BE PROCESSED.
I HEREBY AGREE TO COMPLY WITH ALL PROVISIONS OF CHAPTER 23, ARTICLE II,
TREE PROTECTION, AND ALL OTHER APPLICABLE CODES AND ORDINANCES OF
THE CODE OF O INANCES OF ATLANTIC BEACH.
Applicant's Signature Date
Owne 's Signature Date
CITY USE ONLY:
w
Tree Conservatio d Chairperson Date
o v U K. 8 , P A G E 4
0 20' ALLEY BY PLAT BOOK 19, PAGE 16 IS THE
HEREIr
LU IN AU'
a so(m'06"E 214.76' of TNI
24-86 PCSP 84.48 PCSP �,21.12 BE ADi
Go- ON TNI
o RECORI
m PC w PT
=r •s l 1p
L O T 6 L O T 5 Fl
- e7 co u) m H 41
x tw.9z C-4 v 0
m d D E Q
o4 � � rn
m u1 �
z N00'00'46"W 99:41' NOO'00'46"W 99.42'
-' cv Y
Y m 49.70' 49.71' 49.71' 49.71' 0
0 0
O O m
z [D C4
°� ►
6.00'-
10-00'
.00'--+-10-00' J
w J p
a � N
a p °' }
m -4 00 � m
oyL 0 T 1 '- 0 T 2 L 0 T 3 3 LOT 4 r., W
m w 1 p d 0o w J
o
J w � o r
a Q rnp� O 0) a
co
rJ 0 in
Q) N r Ln Qj
F rn
O z00
z
O
}
PT PC
o
4.94' PCSP 34,88' 49.71' 49.71' 34.63 PCSP-,5V21.O
N00'00 48 214.96'
FRANCIS AVENUE
NAIL do DISK S00'00'46"E 301.02'
,BEN & ASSOC (30' RIGHT—OF—WAY Bt' PLAT BOOK 19, PAGE 16)
�0 30 9
CITY F A LANTIC BEACH PERMIT CALCULATION SHEET
Address Il /Zf�NC ( S V Fi
Date
Heated Sauare Footage .� @ per sa ft =
Garag She - �c( @ $ Z� per sq ft. =
Carlaart rc: .._.._per sq
Deck �@ $ per sq ft = S
Patio a $ per sq ft = 8 _
DOTAL VALUATION ; 5
r T, ,
Total Valuation 1st $
S
Remaining Value $ per thousand
or Dortion thereof
TOTAL BUILDING FEE S
+ 1 /2 Filing Fee $
(0) Fireplaces @ S15 , 00
BUILDING PERMIT FEE $
WATER IMPACT FEE $_ , 0?-) ,
SEWER IMPACT FEE $ ! 2 5-G.C}
WATER METER/TAP $___ 5 v
CAPITAL IMPROVEMENT
SEWER TAP
ZVI RADON (HRS) .C050ION H PAVING ( $i
HYDRAULIC SHARES --
CROSS CONNECTION
J17a) SURCHARGE . 0050
rHER
GRAND TOTAL DUE
ADDITIONAL PERMITS OR FEES; : Mechanical Plumbing
Electric/New Electric/Temp ; Swimmingpool
Septic Tankwe'_ i Sign Finish Floor Elevation
Survey ; other
CALCULATIONS anti/or NOTES:
PLAN REVIEW CHECKLIST
PROPERTY DESCRIPTION: l -/ /"/L wo,(S U r
OWNER: ' /
1. Determine Occupancy Classification of the structure. Select occupancy classification f
which most accurately fits the use of the Building. (Chapter B3)
[Vf 2. Determine actual physical properties of building.
[ a. Determine building area each floor. (Area definition Chapter B2)
b. Determine grade elevation for building. (Grade definition Chapter 132)
C. Determine building height in feet above grade. (Height definition Chapter B2)
U d. Determine building height in stories. (Story definition Chapter B2)
e. Determine separation distance from exterior walls to assumed and common
property lines. (Property line definition Chapter 132)
E/] f. Determine percent of exterior openings per floor.
[Jj 3. Determine minimum Type of Construction necessary to accommodate proposed structure.r.
(Chapter 136)
[✓f a. Determine maximum allowable heights and floor areas for Types of Construction
and Occupancy classification. (Table B500)
[VI b. Check allowable height and area increases permitted. (Chapter 135)
[lj 4. Check detailed Occupancy requirements. (Chapter B4)
[V) 5. Check detailed Construction requirements
[� a. Fire Protection of Structural Members(Chapter B6&Table B600)
G/f b. Fire Protection Requirements(Chapter B7 and Table B700)
[�
C. Means of Egress Requirements(Chapter B10)
[ d. Special restrictions if in Fire District. (Appendix BF The provisions of Appendix BF
are applicable only where specifically adopted by Ordinance)
j df 6. Review design as related to standards. (Chapters B16-B26)
7. Check other requirements as necessary.
a. Construction projecting into public property(chapter B32)
[�I b. Elevators and conveying systems(Chapter B30)
M C. Sprinklers,standpipes and alarm systems(Chapter B9)
[ d. Use of combustible materials on the interior(Chapter B8)
[Y e. Roofs and roof structures(Chapter B15)
[�] f. Light,ventilation and sanitation (Chapter B12)
[ l 9• Other
- 2 L CITY OF ATLANTIC BEACH BUILDING DEPARTMENT
Date n
By: � L Com---
Don C. Ford, Building/Official
don/sb.1
REC"
PROPERTY DESCRIPTION
# X" `Bloc # ?eetion 'i C
division: L9i°ti°°°,, and Zoning
� �
Street Name DESCRIPTION OF WORK
or Address:
(If in a FLOOD HAZARD
Flood Zone: area complete page 3)
Brief Description
Class of Work: (New/ ,
Remodel/Addition: 1—x6,(-�
ZONING INFORMATION Type of Construction: �-
Zoning Proposed
District:--� ` Use: ze,�, Estimated Value $
Exceptions or Variances Materials:
Granted:
Solid or Fild/J
L -Ground:�
R of:
Method oina- k
OWNER INFORMATION
r /
Property Owner: e Phone:
Mailing Address f
Zip:
CONTRACTOR INFORMATION
Contractor. , r Phone: j�24 — �
Mailing d ress:
zip Z
Expiration
STATE L NSE NO: Date:
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO
BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK
WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL
RULES, REGULATIONS, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDING THE GOVERNING OF
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE
ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND
THAT THE PLANS AND SUPPORTING DATA HA BEEN R L B PROVIDED AS REQUIRED.
Owner Signature ` P ,( DATE
Contractor Signature DATE
N 0 AND SUBSCRIBEDFORE ME BYGR�i6-_ vl�K �� —7�
'� THIS / DAY
`� " • HAYWOOD M.BALL
OTARY PUBLIC
a=
MY Comm #CC606678 ex gyres
R
January 21, 2001
raa,�,nr Bonded thr,°Troy Fain Insurance,Inc.
FLOODPLAIN DEVELOPMENT INFORMATION
Location:: -L�7 k c l -2
Type of Development: '
1
Flood Zone:
Required Lowest Floor Elevation: , j
If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB
HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above
the base flood elevation established for that zone.
No final inspection will be made and no certificate of occupancy will be issued until the survey is
on file with the Building Department.
COMMENTS:
Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon
the above information being correct and that the plans and supporting data have been or shall be
provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11
and all other laws or ordinances affecting the proposed development.
Date /10-� Applicant's Signature ez e- C `
Department Use:
Required Lowest Floor Elevation
As Built Lowest Floor Elevation
Survey Filed with Building Department
Building Department Representative
CITY OF ATLANTIC BEACH
TREE REMOVAL APPLICATION
All applications must submitted with seven(7) copies and received by 5 PM on.Friday ten(10)
days prior to the scheduled meeting in order to be placed on the agenda. * INCOMPLETE
APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE
PROCESSED.
1.
APPLICANT NAME ADDRESS TELEPHONE
2.
ADDRESS OR LEGAL DESCRIPTION OF TREE REMOVAL SITE
3. REASON FOR PROPOSED TREE REMOVAL:
4.HAS THIS SITE BEEN TO THE TREE BOARD BEFORE? ❑YES ❑ NO ❑ NOT SURE
5. PROPERTY ZONING: ❑ RESIDENTIAL ❑ COMMERCIAL
6. LIST TREES PROPOSED FOR REMOVAL:
INTERIOR OR
SPECIES DIAMETER * EXTERIOR ZONE**
r.
E
*Diameter at Breast Height(D.B.H.)is measured at 4.5 feet above grade. To accurately determine
diameter,measure the trunk circumference and divide by 3.14. Diameter of multi-trunked trees is
determined by adding together the diameter of each trunk as measured immediately above the
forks.
` k,M,•J�� � M
� f
+ 1
VIP
.91
o o
o,9 wZ'
INA
Ott
yin
ice' t�� �1d 3� •� 1Q� � ���/'
5.�yNtX�
.
5
I
TakeOff Shl et
HOLMES LUMBER COM ANY JOB #: 0-0358
6550 Roosevelt Blvd . Date: 02/25/00
Jacksonville, FL 2230 Delivery Date: 00/00/00
(904) 772-6100.
Builder: Job Location:
HABITAT OF JAX . BEACH LOT
Salesman: PAUL ADAMS
ty pan russ Profile Pitch Overhangs Cantilevers
FT IN SX Description Left Right Left Right
2 25' 4 .00 1 ' 4" 1 ' 4" 0 ' 0 ' 67741
TIG
23 25' 4 .00 1 ' 4" 1 ' 4" 0 '- 0 ' 67737
T1
I
Notes:
ATP RIP— MP1t— • AIPSn. En91-16O P-0uet6. Inc. • 1]]1 S.W. Ttn AVPPY�. P....— •I-10. ]]060 • 1-600-766-6066 FORM-2.REP
PAGE 1
klBulmiderS
Builders FirstSource
FirstSourceTruss Co.
6550 Roosevelt Blvd.
Jacksonville, Florida 32244
Phone: (904) 772-6100
Fax: (904) 772-1973
JOB: 0-0358
CUSTOMER: HABITAT OF BEACH
LOCATION 1565 FRANCIS
BUILD SET
I. Truss Takeoff
II. Layout
III. Engineering
IV. Framing Details
V. Simpson Strong-Tie Hanger Details
VI. HIB-91 Summary Sheet
Builders FirstSource.Policy re: Repair,correction or rebuilding of faulty trusses. This company is not liable or
subject to any backcharges levied against it by a customer unless that customer so notifies Builders FirstSource in
writing of the problem and allows Builders FirstSource a reasonable amount of time to correct, alter or remake the
truss or trusses to solve the existing problem.
J o b: -0 3 5 7 LOT T4 THIS DWG. PREPARED FROM COMPUTER INPUT LOADS & DIMENSIONS SUBMITTED BY TRUSS MFR.
TOP CHORD 2x4 SP #2 N 100 MPH WIND, 15.00 FT MEAN HGT, SBCCI,
BOT CHORD 2x4 SP #2 N ENCLOSED BLDG, NOT LOCATED WITHIN 8.50 FT FROM ROOF EDGE.
WEBS 2x4 SP #3 WIND TC OL - 5.0 PSF, WIND BC OL - 5.0 PSF.
A RIGID CEILING OR CONTINUOUS LATERAL BRACING AT 24' O.C. ROOF OVERHANG DESIGNED FOR A 2.00 PSF SOFFIT LOAD.
MUST BE PROPERLY ATTACHED TO THE BOTTOM CHORD.
12.6" 12.6"
T W4X4
4 12
W1.5X3 W1.5X3 !n
v o
u�
W2X6(A1) W2X6(AS)� 8'1"2
W W4X (�'
25' w
Rv-1005# U=500# W-3"8 Rv-1005# U-500# W-3'8
TAG = T13 SEG = 67949
PLATE-WAVE TPI95 TPI STD QTY= 12 PLIES= 1 TOTAL= 12 REV. 18.2f3 SCALE =0.2500
ALPINE ENGINEERED PRODUCTS, INC. TRUSSES REQUIRE EXTREME CARE T C L L 20.0 PSF REF
*IMP 0 R T AN T**SHALL NOT BE RESPONSIBLE FOR ANY WARNINGIN HANDLING, ERECTION AND
DEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY BRACING. SEE HIB-91 BY TPI. SEE THIS DESIGN TC DL 7.O PSF DATE 03/06/00
FAILURE TO BUILD THE TRUSS IN CONFORMANCE WITH OSTBB BY TPI. FOR ADDITIONAL SPECIAL PERMANENT BRACING RE
ALPINE CONNECTORS ARE MADE OF 2OGA GALV. STEEL MEETING ASTM OUIREMENTS. UNLESS OTHERWISE INDICATED, TOP BC DL 10.0 PSF DRWG
A446 GR 6 EXCEPT AS NOTED. APPLY CONNECTORS TO EACH FACE OF CHORD SHALL BE LATERALLY BRACED WITH PROPER
TRUSS AND UNLESS OTHERWISE LOCATED ON THIS DESIGN, POSITION LY ATTACHED PLYWOOD SHEATHING, BOTTOM CHORD BC LL 0•O PSF MSK
CONNECTORS PER DRAWINGS 130, 150 & 15OA-F. DESIGN STANDARDS WITH PROPERLY ATTACHED RIGID CEILING--SEE TOT.LD. 37.O PSF 0/A LEN. 25
CONFORM W/APPLICABLE PROVISIONS OF NOS& TPI. AN ENGINEER'S ALPINE TECHNICAL UPDATE (7/1/911 FOR PROPER
SEAL ON THIS DRAWING APPLIES TO THE COMPONENT DEPICTED HERE DRYWALL APPLICATION. FURNISH A COPY OF THIS DUR.FAC. 1 .25 -
IN ONLY, AND SHALL NOT BE RELIED UPON IN ANY OTHER WAY. DESIGN TO THE TRUSS ERECTION CONTRACTOR,
BEACHES HABITAT
HVAC LOAD ANALYSIS
for
am
Wwwwwww
t
a
M1MMI,
WAC LoADs
n,.y N.t+M11 !i
Prepared By:
i ()i #� , ;;'i4il Andy Bryan
t fA,BLOcean State Heating&Air Conditioning
1476 Atlantic Boulevard
Neptune Beach,FL 32266
(904)249-8251
3-5-99
Project: Beaches Habitat Company: Ocean State Heating &Air Conditioning
Client: Beaches Habitat Representative: Andy Bryan
Address: P.O. Box 50939 Address: 1476 Atlantic Boulevard
City: Jacksonville Beach, FL 32240 City: Neptune Beach, FL 32266
Phone: (904)241-1222 Phone: (904)249-8251
Fax: Fax: (904)249-8949
d71
. �
Project Name: Beaches Habitat
Reference City: Jacksonville, Florida
Daily Temperature Range: Medium
Latitude: 30 Degrees
Elevation: 26 Feet
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter: 27 N/A N/A 72 N/A
Summer: 96 78 50% 75 51
Total Building Supply CFM: 767 CFM per square foot: 0.72
Square feet of room area: 1,066 Square feet per ton: 583.902
Total heating required with outside air: 23,326 Btuh 23.326 MBH
Total sensible gain: 16,869 Btuh 85
Total latent gain: 2,898 Btuh 15
Total cooling required with outside air: 19,767 Btu h 1.647 Tons (based on sensible+ latent)
1.826 Tons (based on 77% sensible capacity)
F f �
Y
.yi.,.x!:
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
z o•�'�,a ;s .,.o,'
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3C Window Double Pane Clear Glass Metal Frame 130 4,241 0 6,243 6,243
1 OD Door Wood Solid Core 38 787 0 430 430
12C Wall R-11 + 1/2" Gypsum(R-0.5) 980 3,968 0 2,168 2,168
16G Ceiling R-30 Insulation 1,066 1,583 0 1,583 1,583
22A Slab on Grade No Edge Insulation 146 5,321 0 0 0
Subtotals for structure: 2,360 15,900 0 10,424 10,424
Active People: 4 0 920 1,200 2,120
Inactive People: 0 0 0
0 0
Appliances: 0 0 0 2400 2,400
Lighting: 0 0 0 0, 0
Ductwork: 0 1,110 0 1,535 1,535
Infiltration:Winter CFM: 127.7, Summer CFM: 56.8 168 6,316 1,978 1,310 3,288
Ventilation:Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain Total: 16,869
Temperature Swing Multiplier: X1.00
Building Load Totals: 23,326 2,898 16,869 19,767
hL
Total Building Supply CFM: 767 CFM per square foot: 0.72
Square feet of room area: 1,066 Square feet per ton: 583.902
a="
Total heating required with outside air: 23,326 Btuh r 23.326 MBH
Total sensible gain: 16,869 Btuh 85
Total latent gain: 2,898 Btuh 15 %
Total cooling required with outside air: 19,767 Btuh 1.647 Tons (based on sensible+ latent)
1.826 Tons (based on 77% sensible capacity)
7777777-77777
01
RIN
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
�/�`ll p ,'�, a, s; .? a .,!� t,.,�:�:.. a„ cm..• s: �,�'`.: .t Asa.�. .arra
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3C Window Double Pane Clear Glass Metal Frame 130 4,241 0 6,243 6,243-
10D Door Wood Solid Core 38 787 0 430 430
12C Wall R-11 + 1/2" Gypsum(R-0.5) 980 3,968 D 2,168 2,168
16G Ceiling R-30 Insulation 1,066 1,583 0 1,583 1,583
22A Slab on Grade No Edge Insulation 146 5,321 0 0 0
Subtotals for structure: 2,360 15,900 0 10,424 10,424
Active People: 4 0 920 1,200 2,120
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 2,400 2,400
Lighting: 0 0 0 0 0
Ductwork: 0 1,110 0 1,535 1,535
Infiltration:Winter CFM: 127.7, Summer CFM: 56.8 168 6,316 1,978 1,310 3,288
Ventilation:Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain Total: 16,869
Temperature Swing Multiplier: X1.00
System Load Totals: 23,326 2,898 16,869 19,767
77
0-11.fir,FIT-
Supply CFM: 767 CFM per square foot: 0.72
Square feet of room area: 1,066 Square feet per ton: 583.902
Total heating required with outside air: 23,326 Btuh 23.326 MBH
Total sensible gain: 16,869 Btuh 85 %
Total latent gain: 2,898 Btuh 15 %
Total cooling required with outside air: 19,767 Btuh 1.647 Tons (based on sensible+ latent)
1.826 Tons(based on 77% sensible capacity)
v,L ,
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Y .��q S e• rc � �'� x tl ��.� q., Y '$�v�"ri°F b w&4'y'N
rt
.s £. ;�, ��, ,'.,r> �•kz �r"� �p� x�s�.3'�rd� ,�: r��.a 1j'�k � �<� � zn
Htg Htg Run Run Clg Clg Clg Zone Clg Air
Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM
---Zone 1---
1 Master 176 5,505 72 0-0 0 3,594 884 164 1.00 164 164
Bedroom
/Bath
2 Bath 2 100 2,250 29 0-0 0 2,101 212 96 1.00 96 96
3 Bedroom 137 2,195 29 0-0 0 2,054 407 93 1.00 93 93
8
4 Living 233 6,519 85 0-0 0 3,328 647 151 1.17 177 151
Room
5 Dinette 105 3,054 40 0-0 0 1,209 235 55 1.30 72 55
6 Kitchen 98 1,284 17 0-0 0 2,350 . 106 107 1.25 134 107
7 Bedroom 217 2,519 33 0-0 0 2,233 407 102 1.25 127 102
2
System 1 Totals 1066 23,326 303 16,869 2,898 767 861 767
Main Trunk Size: 12x12 in.
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 1.647 85%/15% 16,869 2,898 19,767
Recommended: 1.826 77%/23% 16,869 5,039 21,908
11111m;lip a
'-.. •1, s a
Heating System Coolinq System
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: Beaches Habitat Builder: Beaches Habitat
Address: Permitting Office:
City, State: , FL 32250- Permit Number:
Owner: Jurisdiction Number:
Climate Zone: North
1. New construction or existing New - 12. Cooling systems
2. Single family or multi-family Single family - a. Central Unit Cap: 100.0 kBtu/hr _
3. Number of units,if multi-family 1 - SEER_ 10.00 _
4. Number of Bedrooms 3 _ b.N/A _
5. Is this a worst case? No _
6. Conditioned floor area(ft2) 1066 ft2 c. N/A
7. Glass area&type _
a. Clear-single pane 0.0 ft2 _ 13. Heating systems
b. Clear-double pane 130.0 ft2 _ a. Electric Heat Pump Cap: 100.0 kBtu/hr _
c. Tint/other SC/SHGC-single pane 0.0 ft2 _ HSPF:7.00 _
d.Tint/other SC/SHGC-double pane 0.0 ft2 b.N/A _
8. Floor types _
a. Slab-On-Grade Edge Insulation R=0.0,146.0(p)ft _ c.N/A
b.N/A
c.N/A 14. Hot water systems
9. Wall types _ a.Electric Resistance Cap:50.0 gallons _
a. Frame,Wood,Exterior R=11.0,980.0 ft2 _ EF:0.92 _
b.N/A _ b.N/A
c.N/A _
d.N/A _ c. Conservation credits _
e.N/A (HR-Heat recovery,Solar
10. Ceiling types _ DHP-Dedicated heat pump)
a.Under Attic R=30.0, 1066.0 ft2 _ 15. HVAC credits _
b.N/A _ (CF-Ceiling fan,CV-Cross ventilation,
c.N/A HF-Whole house fan,
11. Ducts _ PT-Programmable Thermostat,
a. Sup:Unc. Ret:Unc. AH:Attic Sup.R=6.0,25.0 ft _ RB-Attic radiant barrier,
b.N/A MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.12 Total as-built points: 16762.00 PASS
Total base points: 17597.00
I hereby certify that the plans and specifications covered Review of the plans and
by this calculation are in compliance with the Florida specifications covered by this o4zx>3S0.
Energy Code. calculation indicates compliance
PREPARED BY: Andy Bryan with the Florida Energy Code. M
DATE: Before construction is completed
this building will be inspected for
I hereby certify that this b ' g, as designed, i i compliance with Section 553.908 �.coD �gt
compliance with the Flo d E r Co,de. Florida Statutes.
OWNER/AGE T• BUILDING OFFICIAL:
DATE: 3 DATE:
EnergyGauge®(Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL, 32250- PERMIT#:
BASE AS-BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points
.18 1066.0 33.05 6342.5 Double,Clear N 1.5 4.0 6.0 19.22 0.88 101.4
Double,Clear N 1.5 6.0 15.0 19.22 0.94 2700
Double,Clear W 1.5 6.0 15.0 36.99 0.91 506.7
Double,Clear E 1.5 6.0 15.0 40.22 0.91 550.7
Double,Clear E 1.5 6.0 15.0 40.22 0.91 550.7
Double,Clear S 1.5 6.0 20.0 34.50 0.86 590.7
Double,Clear S 6.0 6.0 20.0 34.50 0.52 359.2
Double,Clear W 1.5 4.0 9.0 36.99 0.81 270.9
Double,Clear W 1.5 6.0 15.0 36.99 0.91 506.7
As-Built Total: 130.0 3707.7
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adajcent 0.0 0.0 0.0 Frame,Wood, Exterior 11.0 980.0 1.70 1666.0
Exterior 980.0 1.70 1666.0
Base Total: 980.0 1666.0 As-Built Total: 980.0 1666.0
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 6.10 231.6
Exterior 38.0 6.10 231.8
Base Total: 38.0 231.8 As-Built Total: 38.0 231.8
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Under Attic 1066.0 0.60 639.6 Under Attic 30.0 1066.0 0.60 639.6
Base Total: 1066.0 639.6 As-Built Total: 1066.0 639.6
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 146.0(p) -37.0 -5402.0 Slab-On-Grade Edge Insulation 0.0 146.0(p) -41.20 -6015.2
Raised 0.0 0.00 0.0
Base Total: -5402.0 As-Built Total: -6015.2
INFILTRATION Area X BSPM = Points Area X SPM = Points
1066.0 10.21 10883.9 1066.0 10.21 10883.9
EnergyGauge®DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRONA-200
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL,32250- PERMIT#:
BASE AS-BUILT
Summer Base Points: 14361.8 Summer As-Built Points: 11113.8
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
11113.8 1.000 1.089 0.341 1.000 4130.3
14361.8 0.3573 5131.5 11113.8 1.00 1.089 0.341 1.000 4130.3
EnergyGaugeTm DCA Form 60OA-97 EnergyGaugeWFIaRES'97 FLRCNA-200
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL, 32250- PERMIT#:
BASE AS-BUILT
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Points
18 1066.0 9.76 1873.7 Double, Clear N 1.5 4.0 6.0 14.30 1.01 86.3
Double, Clear N 1.5 6.0 15.0 14.30 1.00 215.1
Double,Clear W 1.5 6.0 15.0 10.77 1.02 165.3
Double,Clear E 1.5 6.0 15.0 9.09 1.04 141.2
Double, Clear E 1.5 6.0 15.0 9.09 1.04 141.2
Double,Clear S 1.5 6.0 20.0 4.03 1.12 90.1
Double,Clear S 6.0 6.0 20.0 4.03 2.73 220.2
Double, Clear W 1.5 4.0 9.0 10.77 1.05 102.1
Double, Clear W 1.5 6.0 15.0 10.77 1.02 165.3
As-Built Total: 130.0 1326.8
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adajcent 0.0 0.0 0.0 Frame,Wood, Exterior 11.0 980.0 3.70 3626.0
Exterior 980.0 3.70 3626.0
Base Total: 980.0 3626.0 As-Built Total: 980.0 3626.0
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 12.30 467.4
Exterior 38.0 12.30 467.4
Base Total: 38.0 467.4 As-Built Total: 38.0 467.4
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Under Attic 1066.0 1.20 1279.2 Under Attic 30.0 1066.0 1.20 1279.2
Base Total: 1066.0 1279.2 As-Built Total: 1066.0 1279.2
FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Slab 146.0(p) 8.9 1299.4 Slab-On-Grade Edge Insulation 0.0 146.0(p) 18.80 2744.8
Raised 0.0 0.00 OA
Base Total: 1299.4 As-Built Total: 2744.8
INFILTRATION Area X BWPM = Points Area X WPM = Points
1066.0 -0.59 -628.9 1066.0 -0.59 -628.9
EnergyGauge®DCA Form 60OA-97 EnergyGaugeWFIaRES'97 FLRCNA-200
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL, 32250- PERMIT#:
BASE AS-BUILT
Winter Base Points: 7916.7 Winter As-Built Points: 8815.3
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
8815.3 1.000 1.107 0.487 1.000 4751.9
7916.7 0.5340 4227.5 8815.3 1.00 1.107 0.487 1.000 4751.9
EnergyGaugelm DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL,32250- PERMIT#:
BASE AS-BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2746.00 8238.0 50.0 0.92 3 1.00 2626.61 1.00 7879.8
As-Built Total: 7879.8
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points` Points Points Points Points Points
5131.5 4227.5 8238.0 17597.0 4130.3 4751.9 7879.8 16762.0
EF:PASS
o4'T S .
Nry/ .b3 1
a
COD wB t�v
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/RaRES'97 FLRCNA-200
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: Third Avenue South,Jacksonville Beach, FL,32250- PERMIT#:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area;.5 cfm/s .ft.door area.
Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall;
foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility
penetrations;between wall panels&top/bottom plates;between walls and floor.
EXCEPTION:Frame walls where a continuous infiltration barter is installed that extends
from,and is sealed to,the foundation to the to late.
Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members.
EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter,penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor,around shafts,chases,
soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate;
attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is
Installed that Is sealed at the perimeter,at penetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,Installed inside a
sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from
conditioned space,tested.
Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences.
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics:R-6 min.insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling&floors R-11.
EnergyGauge'rm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* =83.0
The higher the score,the more efficient the home.
Third Avenue South, Jacksonville Beach; FL, 32250-
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-family Single family — a. Central Unit Cap: 100.0 kBtu/hr —
3. Number of units,if multi-family 1 — SEER: 10.00 —
4. Number of Bedrooms 3 — b.N/A —
5. Is this a worst case? No — —
6. Conditioned floor area(ft') 1066 ft' c. N/A —
7. Glass area&type — —
a. Clear-single pane 0.0 ft' — 13. Heating systems
b. Clear-double pane 130.0 ft' — a. Electric Heat Pump Cap: 100.0 kBtu/hr —
c. Tintlother SC/SHGC-single pane 0.0 ft' — HSPF:7.00 —
d.Tintlother SC/SHGC-double pane 0.0 ft' b.N/A —
8. Floor types — —
a. Slab-Cm-Grade Edge Insulation R--O.O,146.0(p)ft — c. N/A —
b.N/A — —
c.N/A 14. Hot water systems
9. Wall types — a. Electric Resistance Cap:50.0 gallons —
a. Frame,Wood,Exterior R=11.0,980.0 ft' — EF:0.92 —
b.N/A — b.N/A —
c.N/A — —
d.N/A — c. Conservation credits —
e.N/A (HR-Heat recovery,Solar
10. Ceiling types — DHP-Dedicated heat pump)
a. Under Attic R=30.0,1066.0 ft' — 15. HVAC credits —
b.N/A — (CF-Ceiling fan,CV-Cross ventilation,
c.N/A HF-Whole house fan,
11. Ducts — PT-Programmable Thermostat,
a. Sup:Unc. Ret:Unc. AH:Attic Sup.R=6.0,25.0 ft — RB-Attic radiant barrier,
b.N/A MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed(or exceeded) 4.ti%sTA?,
in this home before final inspection.Otherwise,a new EPL Display Card will be completed 'o, e 80
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPADOE EnergyStar""designation),
Your home may quay for energy efficiency mortgage(EEAV incentives fyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf edufor
information and a list of certified Raters.For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 850/487-1824.
EnergyGauge®(Version:FLRCNA-200)