Loading...
Permit 5809 & 5810 Fleet Landing Blvd r�'l -Ail rf� City of Atlantic Beach Building Department Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: Date: June 12, 2008 Contractor: R.P.C. General Contractors Address: 5809 Fleet landing Blvd., Atlantic Beach, Fl 32233 Construction Type: Residential Occupancy Class: Group R-2 Permit Number: 07-0762 MICHAEL GRIFF BUILDING OFFICIAL FbRM 60OA-2004R EnergyGauge®4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: villa5809 Builder: RPC Address: 5809 Fleet Landing Blvd. Permitting Office: City, State: Atlantic Beach, FL 32233- Permit Number: Owner: Jurisdiction Number: Climate Zone: North 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:39.4 kBtu/hr _ 3. Number of units,if multi-family 1 - SEER:21.00 _ 4. Number of Bedrooms 2 _ b.N/A _ 5. Is this a worst case? No _ 6. Conditioned floor area(ft2) 1670 ftz c. N/A _ 7. Glass type I and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble,U=0.4)242.7 ft' _. a. Electric Heat Pump Cap:39.4 kBtu/hr _ b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear)242.7 ft' _ b.N/A _ 8. Floor types a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. NIA b.N/A _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=21.0, 1000.8 ftz _ EF:0.94 _ b. Concrete,Int Insul,Adjacent R=21.0,142.2 ft' _ b.N/A c. N/A _ d.N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=22.0,1670.0 ft' 15. HVAC credits PT,CF, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A - HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.15 Total as-built points: 13865 PASS Total base points: 20822 I hereby certify that the plans and specifi o s covered by Review of the plans and111! Ti1E ST this calculation are in com n e with th FI rida Energy specifications covered by this O2 'Ta Code. calculation indicates compliance ' PREPARED/BY' with the Florida Energy Code. DATE: Before construction is completed r this building will be inspected for a 1 hereby certify that this building,as designed, is in compliance compliance with Section 553.908 with the Florida Energy Code. Florida Statutes. coo WE OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.JBS ITE COPY FORM 60OA-2004R EnergyGauge®4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points .18 1670.0 18.59 5588.0 1.Double,U=0.45,Clear E 1.0 1.0 160.2 44.10 0.52 3658.0 2.Double,U=0.45,Clear N 1.0 1.0 72.5 21.45 0.71 1105.0 3.Double,U=0.45,Clear S 1.0 1.0 10.0 37.91 0.52 197.0 As-Built Total: 242.7 4960.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 142.2 0.70 99.5 1.Concrete,Int Insul,Exterior 21.0 1000.8 0.17 171.6 Exterior 1000.8 1.70 1701.4 2.Concrete,Int Insul,Adjacent 21.0 142.2 0.17 24.4 Base Total: 1143.0 1800.9 As-Built Total: 1143.0 195.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 2.40 50.4 1.Adjacent Wood 21.0 2.40 50.4 Exterior 42.0 6.10 256.2 2.Exterior Insulated 21.0 4.10 86.1 3.Exterior Insulated 21.0 4.10 86.1 Base Total: 63.0 306.6 As-Built Total: 63.0 222.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1670.0 1.73 2889.1 1. Under Attic 22.0 1670.0 2.11 X 1.00 3523.7 Base Total: 1670.0 2889.1 As-Built Total: 1670.0 3523.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 126.0(p) -37.0 -4662.0 1.Slab-On-Grade Edge Insulation 2.0 126.0(p -38.53 -4855.2 Raised 0.0 0.00 0.0 Base Total: -4662.0 As-Built Total: 126.0 -4855.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1670.0 10.21 17050.7 1670.0 10.21 17050.7 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGaugeO 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT Summer Base Points: 22973.3 Summer As-Built Points: 21097.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 39400btuh,SEER/EFF(21.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 21098 1.00 (1.09 x 1.147 x 1.00) 0.163 0.902 3868.9 22973.3 0.3250 7466.3 1 21097.7 1.00 1.250 0.163 0.902 3868.9 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge8/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point .18 1670.0 20.17 6063.0 1.Double,U=0.45,Clear E 1.0 1.0 160.2 6.75 1.29 1391.0 2.Double,U=0.45,Clear N 1.0 1.0 72.5 12.35 1.02 911.0 3.Double,U=0.45,Clear S 1.0 1.0 10.0 1.34 2.73 36.0 As-Built Total: 242.7 2338.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 142.2 3.60 511.9 1.Concrete,Int Insul,Exterior 21.0 1000.8 1.73 1730.0 Exterior 1000.8 3.70 3703.0 2.Concrete,Int Insul,Adjacent 21.0 142.2 1.56 221.4 Base Total: 1143.0 4214.9 As-Built Total: 1143.0 1961.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 11.50 241.5 1.Adjacent Wood 21.0 11.50 241.5 Exterior 42.0 12.30 516.6 2.Exterior Insulated 21.0 8.40 176.4 3.Exterior Insulated 21.0 8.40 176.4 Base Total: 63.0 758.1 As-Built Total: 63.0 694.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1670.0 2.05 3423.5 1.Under Attic 22.0 1670.0 2.45 X 1.00 4091.5 Base Total: 1670.0 3423.5 As-Built Total: 1670.0 4091.6 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 126.0(p) 8.9 1121.4 1.Slab-On-Grade Edge Insulation 2.0 126.0(p 12.47 1570.8 Raised 0.0 0.00 0.0 Base Total: 1121.4 As-Built Total: 126.0 1570.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 1670.0 -0.59 -985.3 1670.0 -0.59 -985.3 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT Winter Base Points: 14595.6 Winter As-Built Points: 9560.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Electric Heat Pump 39400 btuh,EFF(8.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0 9560.7 1.000 (1.069 x 1.169 x 1.00)0.426 0.950 4838.0 14595.6 0.5540 8086.0 9560.7 1.00 1.250 0.426 0.950 4838.0 EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach,FL, 32233- PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 40.0 0.94 2 1.00 2578.94 1.00 5157.9 As-Built Total: 5157.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 7466 8086 5270 20822 1 3869 4838 5158 13865 PASS 04.Tfw ST91�` fM CpD W8'1� EnergyGaugeTM'DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area;.5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. _ Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker electric or cutoff as must be provided.External or built-in heat trap required. _ Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficient of 78%. _ Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGauge'"' DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =90.6 The higher the score,the more efficient the home. 5809 Fleet Landing Blvd., Atlantic Beach, FL, 32233- 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:39.4 kBtu/hr _ 3. Number of units,if multi-family 1 _ SEER:21.00 _ 4. Number of Bedrooms 2 _ b.N/A _ 5. Is this a worst case? No 6. Conditioned floor area(ft2) 1670 ft2 _ c. N/A 7. Glass type and area:(Label regd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a. (Dble,U=0.4)242.7 ft2 _ a. Electric Heat Pump Cap:39.4 kBtu/hr _ b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear)242.7 ft2 _ b.N/A _ 8. Floor types _ a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. N/A _ b.N/A a N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=21.0,1000.8 ft2 _ EF:0.94 _ b.Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A _ c. N/A d.N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 ft2 _ 15. HVAC credits PT,CF, b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft _ MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building TIiS ST Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card will be completed l/lll ry. ar �` based on installed Code compliant features. Builder Signature: Date: y Address of New Home: City/FL Zip: COD .rg� *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating.If your score is 80 or greater(or 86 for a US EPADOE EnergyStar' designation), your home may quay for energy efficiency mortgage(EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass outut on ages 2&4. EnergyGauge®(Version:FLpRCSB v4.5.2) Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Class 3 Rating 5809 Fleet Landing Blvd. villa5809 Registration No. 0 Atlantic Beach, FL 32233- Climate: North 6/1/2007 Building Loads Base As-Built Summer: 22973 points Summer: 21098 points Winter: 14596 points Winter: 9561 points Hot Water: 4848 points Hot Water: 4848 points Total: 42417 points I Total: 35507 poin#s Energy Use Base As-Built Cooling: 7466 points Cooling: 3869 points Heating: 8086 points Heating: 4838 points Hot Water: 5270 points Hot Water: 5158 points Total: 20822 points Total: 13865 points PASS e-Ratio: 0.67 EnergyGauge®(Version: FLRCSB v4.5) Doc # 2007038237, OR BK 13790 Page 88, Number Pages: 3, Filed & Recorded 02/01/2007 at 04:03 PM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $27.00 THIS INSTRUMENT PREPARED BY AND RETURN TO: JOHN M.WELCH,JR.,Attorney Fla.Bar No.212873 Foley&Lardner LLP One Independent Dr..Suite 1300 P.O.Box 240 Jacksonville.FL 32201-0240 Permit No.06-00033328 Tax Folio No.169384-0010 NOTICE OF COMMENCEMENT STATE OF FLORIDA COUNTY OF DUVAL The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Section 713.13, Florida Statutes,the following information is stated in this Notice of Commencement. 1. Description of Property: See Exhibit A attached hereto. The street address of the property is: various 2. General Description of Improvement: Construction of residential buildings and activity center 3. Owner: Naval Continuing Care Retirement Foundation,Inc. One fleet Landing Boulevard Atlantic Beach,FL 32233 4. Owner's Interest in the Site of the Improvements: Fee simple owner. 5. Fee Simple Title Holder(if Other Than Owner): NIA 6. Contractor: RPC General Contractors,Inc. 248 Levy Road Atlantic Beach,FL 32233 T. Surety On Any Payment Bond: Not applicable 8. Any Person Making a Loan for the Construction of the Improvements: JACKZ80322.1 '3 OR EK 13790 PAGE 89 Wachovia Bank,National Association 225 Water Street,Third Floor Jacksonville,FL 32202 Attn: Lisa Braman and Lorraine Cross 9. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided in Section 713.13(1)(a)(7), Florida Statutes, which service shall constitute service upon Owner. None 10. In addition to himself, Owner designates the following person to receive a copy of the lienor's notice as provided in Section 713.13(1)(b),Florida Statutes: a. Lender named in Paragraph 8 above. b. Contractor named in Paragraph 6 above. 11. Expiration Date of Notice of Commencement(the expiration date is two(2)years from the date of recording unless a different date is specified): Signed: NAV CONTINUING CARE RETIREMENT FOU TION,INC. .A\�— By.. J s rve Ex cutwe 'rector and Authorized Agent STATE OF FLORIDA COUNTY OF DUVAL Swom to and subscribed before me this 29th day of January,2007,by Jahn Meserve,Executive �^ Director and Authorized Agent of Naval Continuing Care Retirement Foundation, Inc., a Florida no ,t-for- profit corporation,on behalf of the corporation. Such person(notary must check applicable box)11111slare personally known to me;or 0 produced a current Florida drivers license as identification;or O produced as identification. [Affix Notary Seal[ 6�&W-Ar'LWW—t— KWENWL (i nWEN [Print or type name] MMI8810N#DD28 o Notary Public,State of E8:SF8&m19,2008 Commission No. "�" My Commission Expires: JACK.580322.1 OR BK 13790 PAGE 90 EXHIBIT A A PART OF THE ANDREW DEWEES GRANT, SECTION 37, AND SECTION 5, ALL IN TOWNSHIP 2 SOUTH,RANGE 29 EAST,CITY OF JACKSONVILLE AND THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE SOUTHWEST CORNER OF THAT CERTAIN TRACT OF LAND TO THE CITY OF JACKSONVILLE, BY CONDEMNATION RESOLUTION NUMBER 70- 801-236,AND BEING RECORDED IN OFFICIAL RECORDS VOLUME 3202, PAGES 481 THROUGH 485 OF THE CURRENT PUBLIC RECORDS OF SAID COUNTY, SAID POINT ALSO BEING ON THE EASTERLY RIGHT-OF-WAY LINE OF MAYPORT ROAD AND/OR STATE ROAD NUMBER 101 (A 100 FOOT RIGHT-OF-WAY AS NOW ESTABLISHED); THENCE SOUTH 09°53'10" WEST, ALONG SAID EASTERLY RIGHT OF WAY LINE OF MAYPORT ROAD, A DISTANCE OF 850.00 FEET TO A POINT ON SAID EASTERLY RIGHT-OF-WAY LINE; THENCE LEAVING SAID RIGHT-OF-WAY LINE RUN NORTH 88055'40"EAST,A DISTANCE OF 534.02 FEET TO THE POINT OF BEGINNING FOR THIS DESCRIPTION; THENCE NORTH 14116'44" WEST, A DISTANCE OF 1.07 FEET; THENCE NORTH 01°04'20"WEST, A DISTANCE OF 119.40 FEET TO THE SOUTHWEST CORNER OF LOT 1, COURTYARDS AT MAYPORT, AS RECORDED IN PLAT BOOK 49,PAGES 67 THROUGH 67C OF SAID CURRENT PUBLIC RECORDS; THENCE NORTH 88°55'40" EAST, ALONG THE SOUTH LINE OF SAID PLAT, A DISTANCE OF 598.78 FEET TO THE SOUTHEAST CORNER OF LOT 13 OF SAID PLAT; THENCE SOUTH 09°53'10"WEST,A DISTANCE OF 1158.12 FEET TO A POINT ON THE SOUTH LINE OF SAID SECTION 5, TOWNSHIP 2 SOUTH, RANGE 29 EAST; THENCE SOUTH 89°23'12"WEST ALONG THE SOUTH LINE OF SECTION 5, A DISTANCE OF 482.25 FEET; THENCE NORTH 09°53'10" WEST, DEPARTING SAID SOUTHERLY SECTION LINE, A DISTANCE OF 361.90 FEET TO A POINT OF INTERSECTION WITH THE SOUTHERLY RIGHT-OF-WAY LINE OF MAYPORT CROSSING BOULEVARD (A VARIABLE WIDTH PUBLIC RIGHT-OF-WAY); THENCE ALONG AND AROUND A CURVE IN SAID RIGHT-OF-WAY LINE CONCAVE WESTERLY AND HAVING A RADIUS OF 50.00 FEET FOR AN ARC DISTANCE OF 5. 157.08 FEET TO THE WESTERLY LINE OF LANDS DESCRIBED AND RECORDED IN OFFICIAL RECORDS VOLUME 6032, PAGE 199, OF SAID CURRENT PUBLIC RECORDS, THE ARC OF LAST SAID CURVE BEING SUBTENDED BY A CHORD BEARING AND DISTANCE OF NORTH 09053'10"EAST,A DISTANCE OF 100.00 FEET; RUN THENCE NORTH 09053'10"EAST ALONG THE EASTERLY BOUNDARY OF LAST SAID LANDS, A DISTANCE OF 569.61 FEET TO THE NORTHEAST CORNER OF SAID LANDS DESCRIBED IN AFORESAID OFFICIAL RECORDS VOLUME 6378, PAGE 657; THENCE SOUTH 88055'40" WEST, A DISTANCE OF 92.23 FEET TO THE POINT OF BEGINNING. JACK.580963.1 �ti� OCT-30-2007 09:07 AMERICAN ELECTRIC 904 737 1069 P.002 Oct 30 2007 9: 37RM RPCGENERRLCONTRACTORS 9042414427 P. 2 EARLY POWER AGREEMENT & RELEASE CITY OF ATLANTIC BEACH Electric power is requested now under the conditions and terms of this Wy executed Ageemeat tit Release 1►cb ad es: eli Permit No. V 7-OW' IP 760M Service Typo(Circle One): Overbcad Underground We,the undersigned General Contractnr and Electrician,understand and agree: 1. "Early Power" isurely for our construction convenience, it is not required by Codes and does not mbstiture for Finalspeetions or the C/O(Certificate of OccupancyMat must be issued bc("ore occupancy, and as such is at the discretion of the Buildmg Official, 2. The City of Atlantic Beach will Yxxake a spagial inspection prior to the early power energizing. All rough inspection must have prior Approval,including meter base connections. 3. Occupancy or use of the new construction before # formal GO cousdMes fiaudaleut use of the early electric, service. Stroh action is expressly probihrted and penalimd by The City of Atlant)c Beach Ordinances. A violation of this Agreement shall result is a request for prompt.removal of electric service after a twenty-four hour notice. 4. "Early Powuee'mrelease authority is the Electrician and/or the Contractor and must not occur bel'nre: b P�7 is complete devices bre and cover and(labeluig rangiced ay.finof inspection). C. Service connection and grounding is complete. d. The electric system has safely passed through electrical check e, Meter can is crmenently ararked wins address. f Z'erpporary ar�dress numbers displuyod(Permanent numbers are required For C/O). 5. Pay$300.administration fee,any tainspection fees and airy autstrtading requirements must bye satisfied prior to release. 6. This fixity completed form is to be submitted to the Building Department by hand,mail or fax. 7. Future such Ag cuts u not be accepted!'tom those wbo violate any ono of the above items. CON'1'RAC'thlt DKI'E d Q D PRINT NAMH ELECTRICIAN' DATE AV"30%'7 _ PRINT NAME XA S S 800 Scminole Road,Atlantic Beach FL 32233 Phoue.(904)247-Sa26, lax:(904)247-5845 htj:/lwy wcoab.us revised 11,29.06 TOTAL P.002 HP Offic;ejet 7410 Lug for Personal Printer/FaxJCopier/Scanner Information Systems 904-247-5845 Oct 31 2007 10:09AM Last Transaction Date Time Type Identification Duration Pages Result Oct 31 10:09AM Fax Sent 96657372 0:58 1 OK CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD r ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 �"rfyr= INSPECTION EMAIL REQUEST: Building-deptgcoab.us Application Number . . . . . 07-00001511 Date 10/31/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---- - ------------ --------------------------------- ------------------ --- ----- Application desc early power ----------------- -------- --------------- ---------- ------- ------------------- Owner Contractor ---- -------------- ------ ------- -- ----- ---------- THE PALMS AT FLEET LANDING AMERICAN ELECTRICAL CONTRACTOR Q/A:GRASS, ROBERT ATLANTIC BEACH FL 32233 5065 ST . AUGUSTINE RD. #3 JACKSONVILLE FL 32207 (904) 737-7770 ---- ------------------ ----------------------------- ---- - -------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 300 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/28/08 ------ ----- --- -------- --- ------------- -- -- ------- - ------- --------- ---------- Fee summary Charged Paid Credited Due ------------ ----- - --- ------ ------ - --- -- ---- ---- - -- ----- -- Permit Fee Total 300 . 00 300 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 300 . 00 300 . 00 . 00 . 00 �o PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. HP Offiicejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Oct 31 2007 10:07AM Last Transaction Date Time Type Identification Duration Parses Result Oct 31 10:07AM Fax Sent 96657372 0:36 1 OK S, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Ji>>° INSPECTION EMAIL REQUEST: Building-dept(a,coab.us Application Number . . . . . 07-00000829 Date 6/18/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Applichtikn desc � � �����&,e Y-�'c 9s LiI�'' ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ AMERICAN ELECTRICAL CONTRACTOR Q/A:GRASS, ROBERT 5065 ST. AUGUSTINE RD. #3 JACKSONVILLE FL 32207 (904) 737-7770 ---------------------------------------------------------------------------- Permit ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/15/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION Date: .07 Property Address: VQ_ Owner: Ree� �OTelephone #• Contractor: ��1�I C1�N V,-K)doL OtoA, Z Telephone #: 3 Contractor Address: R I'!1 Fax #: --jZQ- 9 Contractor Signature C/Ae4l ;1,11 In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: ❑ Trailer Service: If other construction is of New dO Residence ❑ Temp. New being done on this building Or site,list the building ❑ Old ❑ Commercial ❑ Signs ❑ Increase Permit Dumb ❑ Re-wire ❑ Addition Sq.Ft. ❑ Repair Conductor Size: AMPS: COPPER ALUMINUM Switch or RACE Breaker AMPS PH W '13 VOLTA WAY f7p Existing Service RACE Size AMPS PH W VOLT WAY Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP. MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER I H.P. PHS UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon_Transf. Ea. Si n Miscellaneous 800 Seminole Road•Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800• Fax: (904)247-5845• httn://www.ei.atiantic-beach.n.us Revised 1/04 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 F4 INSPECTION PHONE LINE 247-5826 %�1131rti INSPECTION EMAIL REQUEST: Buildin�dept(a,coab.us Application Number . . . . . 07-00000816 Date 6/12/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 15 fixtures ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KING PLUMBING CONTRACTORS INC PAUL T. KING 6900 PHILLIPS HWY, SUITE 50 JACKSONVILLE FL 32216 (904) 296-2568 ---------------------------------------------------------------------------- Permit PLUMBING PERMIT Additional desc . . Permit Fee . . . . 140 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/09/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 140 . 00 140 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 140 . 00 140 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH SS 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 '�1� INSPECTION EMAIL REQUEST: Building-dept&coab.us Application Number . . . . . 07-00000762 Date 6/11/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description TWO FAMILY RESIDENCE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 300000 ---------------------------------------------------------------------------- Application desc DUPLEX HOME ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ R. P.C. GENERAL CONTRACTORS 248 LEVY RD ATLANTIC BEACH FL 32233 (904) 241-4416 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 1060 . 00 Plan Check Fee 530 . 00 Issue Date . . . . Valuation . . . . 300000 Expiration Date . . 12/08/07 ---------------------------------------------------------------------------- Special Notes and Comments *2004 FLROIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2004 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. *PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O. *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *EMAIL INSPECTION REQUESTS TO: BUILDING-DEPTQCOAB.US ---------------------------------------------------------------------------- Other Fees . . . . . . . . . CITY RADON SURCHARGE .41 CAPITAL IMPROVEMENT 325 . 00 ST CONSTRUCTION SURCHARGE 9 . 92 AB CONSTRUCTION SURCHARGE 1 . 10 STATE RADON SURCHARGE 7 . 95 SEWER IMPACT FEES 1250 . 00 WATER IMPACT FEE 460 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1060 . 00 1060 . 00 . 00 . 00 Plan Check Total 530 . 00 530 . 00 . 00 . 00 Other Fee Total 2054 . 38 2054 . 38 . 00 . 00 Grand Total 3644 . 38 3644 . 38 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. i' 141',% CITY OF ATLANTIC BEACH PERMIT ' BUILDING / ZONING DEPARTMENT F APPLICATION # 800 Seminole Road r Atlantic Beach,Florida 32233 .LJlilvi (904)247-5800 , (904)247-5845 Fax t` www.coab.us TRACKING FORM APPLICATION C REQUIRED DEPT:_ Y N PLANING ING Property Address: � / �D�ng z v N ILDING ^�� = Y N O S Applicant: K 0 Y N PUBLIC u1i ILITIES Y N FIRE DEPT. fy� Project: �� my Y N PUBLIC SAFETY co w APPROVAL REQUJIRED AGENCY: RECEIVED BY: INITIAL: DATE: N D.E.P HUFSTETLER 4 Y N S.J.R.W.M. CARPER �O LU Y i. N ARMY CORPS of ENG CARPER O Y HOTELS&RESAURANTS HUFSTETLER APPLICATION STATUS CIRCLE ONE: SITE BUILDI G DA AP VIEWED BY: INITIA DATE: 1 ST REV+ I&Ice 5�i-e S 66 res fey k'ki rz5v PLANNING 2ND REV BUILDING PUBLIC WORKS PUBLIC UTILITIES FIRE DEPT. PUBLIC SAFETY 3RD REV Return this form to the Building Department once you have entered your comments into the AS400- 3. 29-d ;1 �f L,Z 4 01 Crry OF ATLANTIC BEACH j PER ff CALCULATION MEET �o�2 Date Permit Number Address ' Contact Name, Phone Heated Square Footage J(0 @ $ per sl ft=$ 2 Z 6 @ $ persgft=$ rit� h @ $ per sq ft=$ Deck @ $ per sq ft=$ Patio ( $ per sl ft=$ TOTAL VALUATION: $ Total Valuation lst $ Remaining Value $ per thousand or-portion thereof CONSTRUCTION TYPE: TOTAL BUILDING FEE S ZONING: +Y2 Filing Fee $ FLOOD ZONE: ( )Fimplam @$35.00 $ RdPERVIOUS SURFACE: f?�t f AB CONSTRUCTION SURCHARGE $ CAPITAL McROVENIENT = $ `ee'� y�f 4 CITY WON SURCHARGE to 7 $ �'Jl' F / SECTION H A4PACT FEE $ t � SEWER IMPACT FEES $ D SEWER TAP FEES $ t�<`pxcAc�'&j'#ALSTCONSTRUCTIONSURCHARGE 22as $ 9. 9z. jJWfb STATE RADON SURCHAROE 1b yS $ 7.9 WATER CONNECTAIRTER ONLY $ AIIA WATER CONNECT/TAP&METER $ AJIA WATER CROSS CONNECTION $ WATER IMPACT FEE $ OTHER $ G, Ar TOTAL DUE: $ !/13!03 BUILDING PERMIT APPLICATION rj w`Ama CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach FL 32233 Office: (904)247-5826 ■ Fax: (904)247-5845 Job Address: j So T/er 4AWD,WH &/D. t", IF. 322 33 Permit Number: Legal Description ,CT Cil Nom- NaRY>/�cM1�Lt ter tli �'T;o.11 �Li'��cId ��7e�,e71-J1 ryiOV!l'14G�Sc�/✓YJ��� � /cf✓HC. Grp. j'LD,� Valuation of Work(Replacement Cost) $,51V-CW- ■ Class of Work(Circle one): Ne Addition Alteration Repair C—.■ Use of existing/proposed structure s) (Circle one): Commercial If an exi sting sh ucture, is a fire sprinkler system installed? (Circle one): N/ ■ Is approval of homeowner's association or other private entity required? (Circle one): NesNo Describe in detail the type of work to be performed: I &, L60- Property m0- Property Owner Information t , Name:/V,q f!L 6 e)w-rwul,v&Cl��FF' ;,Ecr3uw/'Address:OIIL4�:- City Stater,-- Zip AL1'�-� Phone Contractor Information: Name of Company: --TX<Oualifying Agent:'?ZTomOU&--S Address: eD- State t' Zip 02/ Office Phone J� Job Site/Contact Number -c::�/Y--Y. Y-32 State Certification/Registration# �� C� ''o �'��`� Office Fax#�/ CV A '— L7 'j - Architect Name & Phone# ��i-->;�.� ���� ��=. ��G' -/n i/;,f-cru - 717 Engineer's Name & Phone# d% L L1c�+9 S �/�55oc - of���� L-it �5 -- I o I/- -36,&',& Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to thl issuance of allermit and that all work will be performed to meet the standards ofall laws regulating construction in this1'urisdiction. This permit becomes null am void if work as not commenced within six(6)months, or if construction or work is suspended or abandoned for a period ofsix(6)months at any time after work i, commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers,Heaters,Tanks andAi, Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOL INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEN BEFORE RECOR*heed R NOTICE OF COMMENCEMENT. 1 hereby certiy that I have rthis application and know the same to be true and correct. All provisions o laws and ordinances governing this pr of work will be complied witherein or not. The granting of a ermit does not presume to give author o violate or cancel the provisions ojan other federal,state, or locanstruction or the performance ojconstruction. Signature of Property OwSignature of Contractor:Sworn t and subscribed Swo-ntO and subscr• e be i e this Z�Day of lyipr(, thi Day of Notary Public: Notary Public: pti PU61-11 evert J. ones Commission#DD567168 ti 'eye%, Stacey Brooks ; ,f Expires September 3,2010 r MY COMMISSION# DD140162 EXPIRES T�OF Pn� Bonded Troy Fain-Insurance,Inc.800-385.7019 'a= August 11,2007 BONDED WU TROY FAIN INSURANCE INC DO NOT WRITE BELOW THIS LINE: OFFICE USE ONLY review Result (Circle one): Doc # 2007038237, OR BK 13790 Page 88, Number Pages: 3, Filed & Recorded 02/01/2007 at 04:03 PM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $27.00 THIS INSTRUMENT PREPARED BY AND RETURN TO: JOHN M.WELCH,JR.,Attorney Fla.Bar No.212873 Foley 8 Lardner LLP One Independent Dr.,Suite 1300 P.O.Box 240 Jacksonville,FL 32201-0240 Permit No.06-00033328 Tax Folio No.169384-0010 NOTICE OF COMMENCEMENT STATE OF FLORIDA COUNTY OF DUVAL The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Section 713.13, Florida Statutes,the following information is stated in this Notice of Commencement. 1. Descriotion of Property: See Exhibit A attached hereto. The street address of the property is: various 2. General Description of Improvement: Construction of residential buildings and activity center 3. Owner: Naval Continuing Care Retirement Foundation,Inc. One fleet Landing Boulevard Atlantic Beach,FL 32233 4. Owner's Interest in the Site of the Improvements: Fee simple owner. 5. Fee Simple Title Holder(if Other Than Owner): N/A 6. Contractor: RPC General Contractors,Inc. 246 Levy Road Atlantic Beach,FL 32233 7. Surety On Any Payment Bond: Not applicable 8. Any Person Making a Loan for the Construction of the Improvements: JACK.580322.1 '3 OR EK 13790 PAGE 89 Wachovia Bank,National Association 225 Water Street,Third Floor Jacksonville,FL 32202 Attn: Lisa Braman and Lorraine Cross 9. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided in Section 713.13(1)(a)(7), Florida Statutes, which service shall constitute service upon Owner. None 10. In addition to himself, Owner designates the following person to receive a copy of the lienor's notice as provided in Section 713.13(1)(b),Florida Statutes: a. Lender named in Paragraph 8 above. b. Contractor named in Paragraph 6 above. 11. Expiration Date of Notice of Commencement(the expiration date is two(2)years from the date of recording unless a different date is specified): Signed: NAV CONTINUING CARE RETIREMENT FOU ION,INC. By: s Excrve e 'rector and Authorized Agent STATE OF FLORIDA COUNTY OF DUVAL Swom to and subscribed before me this 29th day of January,2007,by John Meserve,Executive Director and Authorized Agent of Naval Continuing Care Retirement Foundation, Inc., a Florida no)-for- profit o-for- profit corporation,on behalf of the corporation. Such person(notary must check applicable box) is/are personally known to me;or 0 produced a current Florida driver's license as identification;or 17 produced as identification. [Affix Notary Seal) SAL r-TtAIN (Print or type name] W00WASSIONIp028 M Notary Public,State of EORES:Fakwyto,2008 Commission No. My Commission Expires: JACK.580322.1 OR BK 13790 PAGE 90 EXHIBIT A A PART OF THE ANDREW DEWEES GRANT, SECTION 37, AND SECTION 5, ALL IN TOWNSHIP 2 SOUTH,RANGE 29 EAST,CITY OF JACKSONVILLE AND THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE SOUTHWEST CORNER OF THAT CERTAIN TRACT OF LAND TO THE CITY OF JACKSONVILLE,BY CONDEMNATION RESOLUTION NUMBER 70- 801-236,AND BEING RECORDED IN OFFICIAL RECORDS VOLUME 3202, PAGES 481 THROUGH 485 OF THE CURRENT PUBLIC RECORDS OF SAID COUNTY,SAID POINT ALSO BEING ON THE EASTERLY RIGHT-OF-WAY LINE OF MAYPORT ROAD AND/OR STATE ROAD NUMBER 101 (A 100 FOOT RIGHT-OF-WAY AS NOW ESTABLISHED); THENCE SOUTH 09153'10" WEST, ALONG SAID EASTERLY RIGHT OF WAY LINE OF MAYPORT ROAD, A DISTANCE OF 850.00 FEET TO A POINT ON SAID EASTERLY RIGHT-OF-WAY LINE; THENCE LEAVING SAID RIGHT-OF-WAY LINE RUN NORTH 88055'40"EAST,A DISTANCE OF 534.02 FEET TO THE POINT OF BEGINNING FOR THIS DESCRIPTION; THENCE NORTH 14°16'44" WEST, A DISTANCE OF 1.07 FEET; THENCE NORTH 01°04'20"WEST, A DISTANCE OF 119.40 FEET TO THE SOUTHWEST CORNER OF LOT 1, COURTYARDS AT MAYPORT, AS RECORDED IN PLAT BOOK 49,PAGES 67 THROUGH 67C OF SAID CURRENT PUBLIC RECORDS; THENCE NORTH 88°55'40" EAST, ALONG THE SOUTH LINE OF SAID PLAT, A DISTANCE OF 598.78 FEET TO THE SOUTHEAST CORNER OF LOT 13 OF SAID PLAT; THENCE SOUTH 09°53'10"WEST, A DISTANCE OF 1158.12 FEET TO A POINT ON THE SOUTH LINE OF SAID SECTION 5, TOWNSHIP 2 SOUTH, RANGE 29 EAST;THENCE SOUTH 89°23'12"WEST ALONG THE SOUTH LINE OF SECTION 5,A DISTANCE OF 482.25 FEET; THENCE NORTH 09°53'10" WEST, DEPARTING SAID SOUTHERLY SECTION LINE, A DISTANCE OF 361.90 FEET TO A POINT OF INTERSECTION WITH THE SOUTHERLY RIGHT-OF-WAY LINE OF MAYPORT CROSSING BOULEVARD (A VARIABLE WIDTH PUBLIC RIGHT-OF-WAY); THENCE ALONG AND AROUND A CURVE IN SAID RIGHT-OF-WAY LINE CONCAVE WESTERLY AND HAVING A RADIUS OF 50.00 FEET FOR AN ARC DISTANCE OF 157.08 FEET TO THE WESTERLY LINE OF LANDS DESCRIBED AND RECORDED IN OFFICIAL RECORDS VOLUME 6032, PAGE 199, OF SAID CURRENT PUBLIC RECORDS, THE ARC OF LAST SAID CURVE BEING SUBTENDED BY A CHORD BEARING AND DISTANCE OF NORTH 09053'10"EAST,A DISTANCE OF 100.00 FEET; RUN THENCE NORTH 09053'10"EAST ALONG THE EASTERLY BOUNDARY OF LAST SAID LANDS, A DISTANCE OF 569.61 FEET TO THE NORTHEAST CORNER OF SAID LANDS DESCRIBED IN AFORESAID OFFICIAL RECORDS VOLUME 6378, PAGE 657; THENCE SOUTH 88055'40" WEST, A DISTANCE OF 92.23 FEET TO THE POINT OF BEGINNING. JACK.580963.1 � t t r FIRM 60OA-2004R EnergyGauge®4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: villa5809 Builder: RPC Address: 5809 Fleet Landing Blvd. Permitting Office: City, State: Atlantic Beach, FL 32233- Permit Number: Owner: Jurisdiction Number: Climate Zone: North 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:39.4 kBtu/hr _ 3. Number of units,if multi-family 1 - SEER:21.00 _ 4. Number of Bedrooms 2 _ b.N/A _ 5. Is this a worst case? No _ 6. Conditioned floor area(112) 1670 ft2 _ c. N/A _ 7. Glass type and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble,U=0.4)242.7 ft2 _ a. Electric Heat Pump Cap:39.4 kBtu/hr _ b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear)242.7 ft2 _ b.N/A _ 8. Floor types a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. N/A _ b.N/A _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=21.0, 1000.8 ft2 _ EF:0.94 _ b. Concrete,hit Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A _ c. N/A _ d.N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 112 15. HVAC credits PT,CF, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Una AH:Garage Sup.R=6.0,80.0 ft MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.15 Total as-built points: 13865 PASS Total base points: 20822 I hereby certify that the plans and sperm o s covered by Review of the plans and ZtiE sT this calculation are in comp' n e with th FI rida Energy specifications covered by this o4 Code. //��,, calculation indicates compliance PREPARED BY: `� with the Florida Energy Code. DATE: Before construction is completed this building will be inspected for 1 hereby certify that this building,as designed, is in compliance compliance with Section 553.908 with the Florida Energy Code. Florida Statutes. G'pDWE t¢ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) FORM 60OA-2004R EnergyGaugeO 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points .18 1670.0 18.59 5588.0 1.Double,U=0.45,Clear E 1.0 1.0 160.2 44.10 0.52 3658.0 2.Double,U=0.45,Clear N 1.0 1.0 72.5 21.45 0.71 1105.0 3.Double,U=0.45,Clear S 1.0 1.0 10.0 37.91 0.52 197.0 As-Built Total: 242.7 4960.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 142.2 0.70 99.5 1.Concrete, Int Insul,Exterior 21.0 1000.8 0.17 171.6 Exterior 1000.8 1.70 1701.4 2.Concrete,Int Insul,Adjacent 21.0 142.2 0.17 24.4 Base Total: 1143.0 1800.9 As-Built Total: 1143.0 195.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 2.40 50.4 1.Adjacent Wood 21.0 2.40 50.4 Exterior 42.0 6.10 256.2 2.Exterior Insulated 21.0 4.10 86.1 3.Exterior Insulated 21.0 4.10 86.1 Base Total: 63.0 306.6 As-Built Total: 63.0 222.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1670.0 1.73 2889.1 1.Under Attic 22.0 1670.0 2.11 X 1.00 3523.7 Base Total: 1670.0 2889.1 As-Built Total: 1670.0 3523.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 126.0(p) -37.0 -4662.0 1.Slab-On-Grade Edge Insulation 2.0 126.0(p -38.53 -4855.2 Raised 0.0 0.00 0.0 Base Total: -4662.0 As-Built Total: 126.0 -4855.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1670.0 10.21 17050.7 1670.0 10.21 17050.7 EnergyGauge®DCA Form 60OA-2004R EnergyGaugeO/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT Summer Base Points: 22973.3 Summer As-Built Points: 21097.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 39400btuh,SEER/EFF(21.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0QNS) 21098 1.00 (1.09 x 1.147 x 1.00) 0.163 0.902 3868.9 22973.3 0.3250 7466.3 21097.7 1.00 1.250 0.163 0.902 3868.9 EnergyGaugeT" DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point .18 1670.0 20.17 6063.0 1.Double,U=0.45,Clear E 1.0 1.0 160.2 6.75 1.29 1391.0 2.Double,U=0.45,Clear N 1.0 1.0 72.5 12.35 1.02 911.0 3.Double,U=0.45,Clear S 1.0 1.0 10.0 1.34 2.73 36.0 As-Built Total: 242.7 2338.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 142.2 3.60 511.9 1.Concrete, Int Insul,Exterior 21.0 1000.8 1.73 1730.0 Exterior 1000.8 3.70 3703.0 2.Concrete,Int Insul,Adjacent 21.0 142.2 1.56 221.4 Base Total: 1143.0 4214.9 As-Built Total: 1143.0 1951.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 11.50 241.5 1.Adjacent Wood 21.0 11.50 241.5 Exterior 42.0 12.30 516.6 2.Exterior Insulated 21.0 8.40 176.4 3.Exterior Insulated 21.0 8.40 176.4 Base Total: 63.0 758.1 As-Built Total: 63.0 594.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1670.0 2.05 3423.5 1.Under Attic 22.0 1670.0 2.45 X 1.00 4091.5 Base Total: 1670.0 3423.5 As-Built Total: 1670.0 4091.5 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 126.0(p) 8.9 1121.4 1.Slab-On-Grade Edge Insulation 2.0 126.0(p 12.47 1570.8 Raised 0.0 0.00 0.0 Base Total: 1121.4 As-Built Total: 126.0 1570.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 1670.0 -0.59 -985.3 1670.0 -0.59 -985.3 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT Winter Base Points: 14595.6 Winter As-Built Points: 9560.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Electric Heat Pump 39400 btuh,EFF(8.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0 9560.7 1.000 (1.069 x 1.169 x 1.00)0.426 0.950 4838.0 14595.6 0.5540 8086.0 9560.7 1.00 1.250 0.426 0.950 4838.0 EnergyGaugeTM' DCA Form 60OA-2004R EnergyGaugeODIFlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 40.0 0.94 2 1.00 2578.94 1.00 5157.9 As-Built Total: 5157.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 7466 8086 5270 20822 3869 4838 5158 13865 PASS o4T�ST9rFo =S� o a EnergyGaugeTM'DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 5809 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area;.5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Mufti-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker electric or cutoff as must be provided.External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGauge^" DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =90.6 The higher the score,the more efficient the home. 5809 Fleet Landing Blvd., Atlantic Beach, FL, 32233- L New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap:39.4 kBtu/hr - 3. Number of units,if multi-family 1 - SEER:21.00 - 4. Number of Bedrooms 2 - b.N/A - 5. Is this a worst case? No - 6. Conditioned floor area(ft=) 1670 ft2 - c. N/A - 7. Glass typel and area:(Label reqd.by 13-104.4.5 if not default) - a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a. (Dble,U=0.4)242.7 W - a. Electric Heat Pump Cap:39.4 kBtu/hr - b. SHGC: HSPF:8.00 - (or Clear or Tint DEFAULT) 7b. (Clear)242.7 ft2 - b.N/A - 8. Floor types - a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft - c.N/A - b.N/A - - c. N/A 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons - a. Concrete,Int Insul,Exterior R=21.0, 1000.8 ft2 - EF:0.94 - b.Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A - c. N/A - - d.N/A - c. Conservation credits - e. N/A - (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 ft2 - 15. HVAC credits PT,CF, - b.N/A - (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, I L Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft - MZ-C-Multizone cooling, b.N/A - MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building �4 JUE ST,- Construction through the above energy saving features which will be installed(or exceeded) z 0 in this home before final inspection.Otherwise,a new EPL Display Card will be completed �f based on installed Code compliant features. «" s Builder Signature: Date: Address of New Home: City/FL Zip: c'oD WE *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a LIS EPADOE EnergyStar7mdesignation), your home may qualify for energy efficiency mortgage(EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass outut on ages 2&4. EnergyGauge®(Version:FLPRCSIP3 v4.5.2) Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Class 3 Rating 5809 Fleet Landing Blvd. villa5809 Registration No. 0 Atlantic Beach, FL 32233- Climate: North 6/1/2007 Building Loads Base As-Built Summer: 22973 points Summer: 21098 points Winter: 14596 points Winter: 9561 points Hot Water: 4848 points Hot Water: 4848 points Total: 42417 points I Total: 35507 points Energy Use Base As-Built Cooling: 7466 points Cooling: 3869 points Heating: 8086 points Heating: 4838 points Hot Water: 5270 points Hot Water: 5158 points Total: 20822 points Total: 13865 points PASS e-Ratio: 0.67 EnergyGauge®(Version: FLRCSB v4.5) , CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 19 ' INSPECTION EMAIL REQUEST: Building-dept(a,coab.us Application Number . . . . . 07-00001060 Date 7/25/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description ROOF Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 20000 ---------------------------------------------------------------------------- Application desc TNSTALL TILE ROOF 5809/5810 ---------- ------------------------------------------------------------------ Owner Contractor ------------------------ ------------------------ PROFESSIONAL SUNSHINE ROOFING 1017 IRELAND DR DELTONA FL 32725 ---------------------------------------------------------------------------- Permit . . . . . . ROOF PERMIT Additional desc Permit Fee . . . . 90 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 20000 Expiration Date . . 1/21/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 90 . 00 90 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 90 . 00 90 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH �l'"��s�� 800 Seminole Road,Atlantic Beach FL 32233 Office: (904)247-5826 ® Fax: (904)247-5845 ob Address: Jt/ 677 ��' �°� «�- 161 Permit Number: Legal Description Valuation of Work(Replacement Cost) S �4,,e►c�c� ■ Class of Work(Circle one): Ne Addition Alteration Repair ■ Use of existing/proposed structure s (Circle one): - Commercial R entia ■ If an existing structure, is a fire sprinkler system installed?(Circle Dane): o N/A ® Is approval of homeowner's association or other private entity required?(Circle one): Y_t-�s No )escribe in detail the type of work to be performed: "n jA // 11(,,4_ AL/ u� l� � �� ��sr� ,�'/� Ted r ProtAerty Owner Information lame: Address: my State Zip Phone -ontractor Information: name of Company: � . } nt: ity Aikddress: C State / Zip 3�ug office Phone �fS4 a� � � Job Site/Contact Numberi Mate Certification/Registration# «' G? Office Fax# C� krchitect Name&Phone# Engineer's Name&Phone# 4pplication is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance o�f a permit and that all workwill be erformed to meet the standards of all 'aws regulating construction.in this jurisdiction, This permit becomes null and void ifwork is not commenced within six(6) Months, orf construction or work as suspended or abandoned for a period of six f6) months at any time mer work is �ommence . I understand that separate permits must be secured for Electrical ork, Plumbing, Signs, ells,Pools, Furnaces,Poilers,�Ieaters, Wanks and Air Conditioalers, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU [NTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. thereby certify that have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this ty�e of work will be complied with whether specified herein or not granting of a Permit does not presume to give aut.writ'y' to violate or Cancel the provisions of any other deral, st or local law regulating construction or the performance of construction. Signature of Property Owner: Signature of Contra Sworn to and subscribed before me Sworn to and subscribed before me this_Day of this Day of [Notary Public: Notary Public: REVISED 03.05.07 CITY OF ATLANTIC BEACH 800 SENIINOLE ROAD -� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-dept@coab.us Application Number . . . . . 07-00001270 Date 9/11/07 Property Address . . . . . . 5809 FLEET LANDING BLVD Application type description MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc INSTALL GEOTHERMAL HP ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PENINSULAR MECHANICAL CONTRACTORS INC P.O. BOX 8116 MADEIRA BEACH FL 33738 (727) 573-4822 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . 69. 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 69. 00 69. 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 69. 00 69. 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. S.DEPART' Or HOMELAND SECURITY t LEVAi��C���`t!I C E r' l IiNC aI f OMB No. 1660-0008 :deral Emergency Management Agency Expires February 28. 2009 ational Flood Insurance Program Important: Reed the instructions on pages 1-8. SECTION A-PROPERTY INFORMATION For Insurance Company Use: 41. Building m Own rs Nae Policy Number nifa ��, 'w�A ef1f0- el', �bAODAi; � PSA C'taCT LA -'D,.,< 42. Building Street Address(inclu trig Apt.,Unit,Suite,and/or Bldg.No.)or P.O. Route and Bo;No. Company NAIC Number ,%6fj. Sc6 ,0 r,.>e- IrE L c 134 City State 1--L ZIP Code 3 ZZ3`3 43. Property Description(Lot and Bloc)c,Numbers,Tax Parcel Number,Legal Deschetion,etc.) R2A 1, (z.F' / :!_15 / Va5,0 s 5 . pt-pr«-s Dv-u/nt-s 6r'0 44. Building Use(e.g.,Residential,Non-Residential,Addition,Accessory,etc,) 45. Latitude/Longitude:Lat.N.":;6 - L I-23 Long. W ` 24 -:12"L Horizontal Datum: ❑NAD 1927 EJtNAD 1983 46. Attach at least 2 photographs of the building If the Certificate is being used to obtain flood insurance. 47. Building Diagram Number 48. For a building with a crawl space or enclosure(s),provide: A9. For a building with an attached garage,provide: a) Square footage of crawl space or enclosure(s) d sq ft a) Square footage of attached garageI�_sq ft b) No.of permanent flood openings in the crawl space or b) No.of permanent flood openings in the attached garage enclosure(s)walls within 1.0 foot above adjacent grade O walls within 1.0 foot above adjacent grade o c) Total net area of flood openings in AB.b _ 0 sq in c) Total net area of flood openings in A9.b sq in SECTION E-FLOOD INSURANCE RATE MAF'(FIRM)INFORMATION 31,NFIP Community Name&Community Number B2.County Name 133.State /Z0 a-7-7 .1,4�rtl t- &A114 / i/o/,r' cl? - B4.Map/Panel Number 65.Suffix B6.FIRM Index B7,FIRM Panel B8.Flood 89.Base Flood Elevation(s)(Zone Date Effective/Revised Date Zo e(s) AO, use base flood depth) i2oo-n o; 6-/6.-1-3sS 8�-1.5_/98S A C Q 10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9. ❑FIS Profile .FIRM ❑Community Determined ❑Other(Describe) 11. Indicate elevation datum used for BFE in Item 69: _NGVD 1929 ❑NAVD 1988 ❑Other(Describe) 12. Is the building located in a Coastal Barrier Resources.System(CBRS)area or Otherwise Protected Area(OPA)? ❑ Yes No Designation Date ❑CBRS ❑OPA SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) i. Building elevations are based on: ❑Construction Drawings" ❑ Building Under Construction RFinished Construction 'A new Elevation Certificate will be required when construction of the building is complete. ?. Elevations-Zones Al-A30,AE,AH,A(with BFE),VE,V1430,V(with BFE),AR,ARIA.,ARAE,AR/A1-A30,AR/AH,AR/AO. Complete Items C2.a-g below according to the buildin diagram specified in Item A7. Benchmark Utilized �S "o. ,s 6 Vertical Datum..-.--,<I G V 'D 1 Z� Conversion/Comments Check the measurement used. a) Top of bottom floor(including basement,crawl space,or enclosure floor) b ®feet ❑meters (Puerto Rico only) b) Top of the next higher floor N - .�0 feet ❑meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member(V Zones only) r'/ .A ❑feet ❑meters (Puerto Rico only) d) Attached garage(top of slab) --/0 ,-�3a Z feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building _ iC.30 W feet ❑meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent(finished)grade(LAG) - feet ❑meters (Puerto Rico only) g) Highest adjacent(finished)grade(HAG) 7v feet ❑meters (Puerto Rico only) _ SECTION D-SURVEYOR,ENGINEER, OR ARCHITECT CERTIFICATION chis certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation nformation, 1 certify that the information on this Certificate represents my best efforts to interpret the data available. understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Check here If comments are provided on back of form. ,ertifiers Name License Number A14 nH k6//ass 5-7/Z i itie Company Name 6 40,0 _5W VC tour Rol- -' W,7 St,, vis S _ addressCity Slate ZIP Code 10c/35 /a�� /� 1�IL,�S�.v, NC_ �L_ 3zLzG Signature Date Z-7-07 a 7 Telephone 70_03/V _MA Form 81-31, February 2006 See reverse side for continuation. Replaces all previous editions IMPf?IRTANT: In these spaces,copy the corresponding information from Section A. For insurance Company Use: Building Street Address(including Ant Unit,Suite,and/or Bldg, No.)or P.O. Route and Box No. Policy Number S8 � .s� City State ZIP Code Company NAIC Number "FL . !?,U35 SECTION D-SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION(CONTINUED) Copy both sides of this Elevation Certificate for(1)community official,(2)insurance agent/company, and(3)building owner. Comments AC Signature Date ❑ Check here if attachments SECTION E-BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A(without BFE),complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request,complete Sections A,B, and C. For Items E1-E4,use natural grade,if available. Check the measurement used. In Puerto Rico only,enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade(HAG)and the lowest adjacent grade(LAG). a)Top of bottom floor(including basement,crawl space,or enclosure)is _❑feet ❑ meters ❑above or ❑below the HAG. b)Top of bottom floor(Including basement,crawl space,or enclosure)is —❑feet ❑meters ❑above or [f below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in SectionA items 8 and/or 9(see a e 8 of Instructions),the next higher floor (elevation 02.b in the diagrams)of the building is _(]feet meters ❑above or (below the HAG. E3. Attached garage(top of slab)is []feet F-1meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is `❑feet ❑meters ❑above or ❑below the HAG. E5. Zone AO only: If no flood depth number is available,is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? F] Yes []No ❑Unknown. The local official must certify this information in Section G. SECTION F-PROPERTY OWNER(OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A.B,and E for Zone A(without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A, B,and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address city State ZIP Code Signature Date Telephone Comments ❑Check here if attachments SECTION G-COMMUNITY INFORMATION(OPTIONAL) rhe local official who is authorized by few or ordinance to administer the community's floodplain management ordinance can complete Sections A,B,C (or E), and G of this Elevation`Certificate. Complete the applicable Item(s)and sign below. Check the measurement used In Items G8. and G9. 31. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,engineer,or architect who is authorized by law to certify elevation Information. (Indicate the source and date of the elevation data in the Comments area below.) 32. ❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE)or Zone AO. 33. ❑ The following information(Items G4.-G9.)is provided for community floodplain management purposes. G4.Permit Number G5. Date Permit Issued 7_Date Certificate Of Compliance/Occupancy Issued _ l 37.This permit has been issued for: F] New Construction ❑ Substantial improvement 38.Elevation of as-built lowest floor(including basement)of the building: El feet ❑meters(PR) Datum 39. BFE or(in Zone AO)depth of flooding at the building site: ❑feet ❑meters(PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑Check here if attachments FEiVIA Form 81-31, February 2006 Replaces all prevlous editions Bufld�ng Photographs See Instructions for Item A6. For Insurance Company Use: Building Street Address(including Apt., Unit, Suite,and/or Bldg. No.)or P.O. Route and Box No. Policy Number city State ZIP Code Company NAIC Number If using the Elevation Celiificate to obtain NFIP flood insurance, affix, at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View"-and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. t City of Atlantic Beach Building Department Certificate of Completion This Certificate issued pursuant to the requirements of Section 110.2 of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: Date: March 14, 2008 Contractor: RPC General Contractors Address: 5810 Fleet Landing Blvd., Atlantic Beach, F1 32233 Construction Type: Residential Occupancy Class: Group R-2 Permit Number: 07-0763 Aa WALT BROWN BUILDING OFFICIAL Building, Planning & Zoning Inspection CITY OF ATLANTIC BEACH Department CERTIFICATE OF OCCUPANCY WORKSHEET Date Requested: -31101d g Contractor Name: �f Permit #: D 7 Property Address: -5'a lb t'-wT ,en Legal Description: Improvements to the above-described property have been completed in accordance with the terms of the permit and are certified to be ready for occupancy as: ❑ Single-Family Residence ❑ Commercial �' ❑r'' Other: Lowest Floor Elevation: Required As Built FFE The following must be completed before issuing Certificate of Occupancy: Department Date Notified Date Approved Approved By Fire Dept. /d Public Works Public Utilities Building Planning Final Survey with FFE Yes No All Re-Inspect Fees Paid Yes No Termite Treatment Yes No CITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD J ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-dept coab.us Application Number . . . . . 07-00000817 Date 6/12/07 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 15 fixtures ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KING PLUMBING CONTRACTORS INC PAUL T. KING 6900 PHILLIPS HWY, SUITE 50 JACKSONVILLE FL 32216 (904) 296-2568 ---------------------------------------------------------------------------- Permit . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 140 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/09/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 140 . 00 140 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 140 . 00 140 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH PLUMBING PERMIT APPLICATION f � I i I! II� � I i 1 , i fl I li' II i G- I i k , i' ppR ' k i I CITY OF ATLANTIC BEACH :L PLUMBING PERMIT APPLICATION „r Dat —42 Property Address: /fie Owner: F /dr'e e4 6 1 J'ov 0A Telephone#• y Contractor: Ie- � 'f""� `� Telephone Contractor Address: 60\© � Fax Contractor Signature: In consideration of permit given for doing the work as describe&o thk above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are alpaA hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing Code. Plumbing Type•• If other construction is being done on this building or site, t New list the building permit number: ❑ Re-Pipe Number of Fixtures: / Bath Tubs / Showers Closets Shower Pans / Dishwashers / Sinks Disposals Urinals Floor Drains Washing Machine J Lavatory / Water ` Sewer Water Heaters Sprinkler System Other *See attached sheet see For Backflow and Irrigation procedures Fees Permit Issuing Fee: /35.00 Total Fixtures: _ X$7.00 + $35.00= 800 Seminole Road •Atlantic Beach, Florida 32233-5445 Phone: (904) 247-5800. Fax: (904) 247-5845. http:l/www.ci.atlantic-beach.fl.us Revised 9/06 FORM 60OA-2004R EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: vi11a5810 Builder: RPC Address: 58010 Fleet Landing Blvd. Permitting Office: City, State: Atlantic Beach, FL 32233- Permit Number: Owner: Jurisdiction Number: Climate Zone: North 1. New construction or existing New — 12. Cooling systems 2. Single family or multi-family Single family — a. Central Unit Cap:39.4 kBtu/hr — 3. Number of units,if multi-family 1 _ SEER:21.00 — 4. Number of Bedrooms 2 _ b.N/A — 5. Is this a worst case? No — — 6. Conditioned floor area(W) 1670 ft2 _ c. N/A — 7. Glass type and area:(Label regd.by 13-104.4.5 if not default) — a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble,U=0A)212.7 ft2 _ a. Electric Heat Pump Cap:39.4 kBtu/hr — b. SHGC: HSPF:8.00 — (or Clear or Tint DEFAULT) 7b. (Clear)212.7 ft2 _ b.N/A — 8. Floortypes — a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. N/A — b.N/A _ — c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons — a. Concrete,Int Insul,Exterior R=21.0, 1000.8 ft2 _ EF:0.94 — b. Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A — c.N/A d.N/A — c. Conservation credits — e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types — DHF-Dedicated heat pump) a. Under Attic R=22.0,1670.0 ft2 15. HVAC credits PT,CF, — b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts — PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft MZ-C-Multizone cooling, b.N/A MZ-H-Multizone heating) Glass/Floor Area: 0.13 Total as-built points: 13479 PASS Total base points: 20822 I hereby certify that the plans and specifications covered by Review of the plans and 4'tuz Sr4T this calculation are in compliance with^Florida Energy specifications covered by this O Code. � calculation indicates compliance PREPARED BY: with the Florida Energy Code. / Before construction is completed DATE: lam' IQ 7 this building will be inspected for O 1 hereby certify that this building,as designed,is in compliance compliance with Section 553.908 with the Florida Energy Code. Florida Statutes. r`i'�+OD W111 OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pa es 2&4. EnergyGauge®(Version:FLRCSB v4.5.2) pa COP} FORM 60OA-2004R EnergyGauge®4,5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points .18 1670.0 18.59 5588.0 1 1.Double,U=0.45,Clear SW 1.0 1.0 150.2 42.20 0.49 3108.0 2.Double,U=0.45,Clear NW 1.0 1.0 52.5 28.18 0.64 944.0 3.Double,U=0.45,Clear SE 1.0 1.0 10.0 44.78 0.49 221.0 As-Built Total: 212.7 4273.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 142.2 0.70 99.5 1.Concrete,Int Insul,Exterior 21.0 1000.8 0.17 171.6 Exterior 1000.8 1.70 1701.4 2.Concrete,Int Insul,Adjacent 21.0 142.2 0.17 24.4 Base Total: 1143.0 1800.9 As-Built Total: 1143.0 195.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 2.40 50.4 1.Adjacent Wood 21.0 2.40 50.4 Exterior 42.0 6.10 256.2 2.Exterior Insulated 21.0 4.10 86.1 3.Exterior Insulated 21.0 4.10 86.1 Base Total: 63.0 306.6 As-Built Total: 63.0 222.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM= Points Under Attic 1670.0 1.73 2889.1 1. Under Attic 22.0 1670.0 2.11 X 1.00 3523.7 Base Total: 1670.0 2889.1 As-Built Total: 1670.0 3523.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 126.0(p) -37.0 -4662.0 1.Slab-On-Grade Edge insulation 2.0 126.0(p -38.53 -4855.2 Raised 0.0 0.00 0.0 Base Total: 4662.0 As-Built Total: 126.0 -4855.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1670.0 10.21 17050.7 1670.0 10.21 17050.7 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT Summer Base Points: 22973.3 Summer As-Built Points: 20410.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 39400btuh,SEER/EFF(21.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 20411 1.00 (1.09 x 1.147 x 1.00) 0.163 0.902 3742.9 22973,3 0.3250 7466.3 1 20410.7 1.00 1.250 0.163 0.902 3742.9 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point .18 1670.0 20.17 6063.0 1.Double,U=0.45,Clear SW 1.0 1.0 150.2 4.69 1.60 1125.0 2.Double,U=0.45,Clear NW 1.0 1.0 52.5 12.05 1.02 648.0 3.Double,U=0.45,Clear SE 1.0 1.0 10.0 2.73 1.94 52.0 As-Built Total: 212.7 1825.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 142.2 3.60 511.9 1.Concrete,Int Insul,Exterior 21.0 1000.8 1.73 1730.0 Exterior 1000.8 3.70 3703.0 2,Concrete,Int Insul,Adjacent 21.0 142.2 1.56 221.4 Base Total: 1143.0 4214.9 As-Built Total: 1143.0 1961A DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 11.50 241.5 1.Adjacent Wood 21.0 11.50 241.5 Exterior 42.0 12.30 516.6 2.Exterior Insulated 21.0 8.40 176.4 3.Exterior Insulated 21.0 8.40 176.4 Base Total: 63.0 758.1 As-Built Total: 63.0 594.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM= Points Under Attic 1670.0 2.05 3423.5 1.Under Attic 22.0 1670.0 2.45 X 1.00 4091.5 Base Total: 1670.0 3423.5 As-Built Total: 1670.0 4091.5 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Stab 126.0(p) 8.9 1121.4 1.Slab-On-Grade Edge Insulation 2.0 126.0(p 12.47 1570.8 Raised 0.0 0.00 0.0 Base Total: 1121.4 As-Built Total: 126.0 1570.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 1670.0 -0.59 -985.3 1670.0 -0.59 -985.3 EnergyGaugeV DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT Winter Base Points: 14595.6 Winter As-Built Points: 9047.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Electric Heat Pump 39400 btuh,EFF(8.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0 9047.7 1.000 (1.069 x 1.169 x 1.00)0.426 0.950 4578.4 14595.6 0.5540 8086.0 9047.7 1.00 1.250 0.426 0.950 4578.4 EnergyGaugeTm DCA Form 60OA-2004R EnergyGaugeOFIaRES'2004R FLRCS8 v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 40.0 0.94 2 1.00 2578.94 1.00 5157.9 As-Built Total: 5157.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water - Total Points Points Points Points Points Points Points Points 7466 8086 5270 20822T 3743 4578 5158 13479 PASS 04��ST9r� ........... EnergyGaugel"DCA Form 60OA-2004R EnergyGauge8/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 68010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.I.1 Maximum:.3 cfm/s .ft.window area;.5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-sto Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker electric or cutoff as must be provided.External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons pw minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =90.9 The higher the score,the more efficient the home. 58010 Fleet Landing Blvd., Atlantic Beach, FL, 32233- 1. New construction or existing New - 12, Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap:39.4 kBtu/hr _ 3. Number of units,if multi-family 1 ` SEER:21.00 _ 4. Number of Bedrooms 2 _ b.N/A 5. Is this a worst case? No _ 6. Conditioned floor area(ft2) 1670 ft2 _ c. N/A 7. Glass type and area:(Label reqd.by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble,U=0.4)212.7 ft2 - a. Electric Heat Pump Cap:39.4 kBtu/hr , b. SHGC: HSPF:8.00 (or Clear or Tint DEFAULT) 7b. (Clear)212.7 ft2 _ b.N/A _ 8. Floor types a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. N/A _ b.N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=21.0, 1000.8 112 _ EF:0.94 _ b.Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A _ c. N/A _ d.N/A _ c. Conservation credits ^ e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 ft2 T 15. HVAC credits PT,CF, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft _ MZ-C-Multizone cooling, b.N/A MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building 4T8E STAB Construction through the above energy saving features which will be installed(or exceeded) ,yO = _ �O in this home before final inspection.Otherwise,a new EPL Display Card will be completed ?r,�*"{�� based on installed Code compliant features. �6? Builder Signature: Date: a Address of New Home: City/FL Zip: cOD WE K4 *NOTE. The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStar""designation), your home may qualijy for energy efficiency mortgage(EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efciency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on ages 2&4. EnergyGauge®(Version:FLpRCSB v4.5.2) Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Class 3 Rating 58010 Fleet Landing Blvd. villa5810 Registration No. 0 Atlantic Beach, FL 32233- Climate: North 6/1/2007 Building Loads Base As-Built Summer: 22973 points Summer: 20411 points Winter: 14596 points Winter: 9048 points Hot Water: 4848 points Hot Water: 4848 points Total: 42417 points I Total: 34307 points Energy Use Base As-Built Cooling: 7466 points Cooling: 3743 points Heating: 8086 points Heating: 4578 points Hot Water: 5270 points Hot Water: 5158 points Total: 20822 points Total: 13479 points PASS e-Ratio: 0.65 EnergyGauge®(Version: FLRCSB v4.5) CITY OF ATLANTIC BEACH r 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building - coab.us Application Number . . . . . 07-00000763 Date 6/11/07 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description TWO FAMILY RESIDENCE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 300000 ------------------------------------------------------------------------ Application desc DUPLEX HOME ----------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ R. P. C. GENERAL CONTRACTORS 248 LEVY RD ATLANTIC BEACH FL 32233 (904) 241-4416 -------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 1060 . 00 Plan Check Fee 530 . 00 Issue Date . . . . Valuation . . . . 300000 Expiration Date . . 12/08/07 -------------------------------------------------------------------------- Special Notes and Comments *2004 FLROIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2004 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. *PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O. *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *EMAIL INSPECTION REQUESTS TO: BUILDING-DEPT@COAB.US ---------------------------------------------------------------------------- Other Fees . . . . . . . . . CITY RADON SURCHARGE .41 CAPITAL IMPROVEMENT 325 . 00 ST CONSTRUCTION SURCHARGE 9 . 92 AB CONSTRUCTION SURCHARGE 1 . 10 STATE RADON SURCHARGE 7 . 95 SEWER IMPACT FEES 1250 . 00 WATER IMPACT FEE 460 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1060 . 00 1060 . 00 . 00 . 00 Plan Check Total 530 . 00 530 . 00 . 00 . 00 Other Fee Total 2054 . 38 2054 . 38 . 00 . 00 Grand Total 3644 . 38 3644 . 38 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH PERMIT r } BUILDING / ZONING DEPARTMENT APPLICATION# 1 r� 800 Seminole Road / 2 v Atlantic Beach,Florida 32233 >� 9' (904)247-5800 (904)247-5845 Fax www.coab.us APPLICATION TRACKING FORM REQUIRED DEPT: Y N PLA NG Property Address: Q ��T � z Y N UILDIN Y N PUBLI ORKS Applicant: Y N PUBLIC I71ES G Y N FIRE DEPT. Project: �� (Yl C� Y N PUBLIC SAFETY W APPROVAL 0 REQU D AGENCY: RECEIVED BY: INITIAL: DATE: Z Y N D.E.P HUFSTETLER Q M Y N S.J.R.W.M. CARPER WW Y N ARMY CORPS of ENG CARPER O Y N HOTELS&RESAURANTS HUFSTETLER APPLICATION STATUS CIRCLE ONE: SITE BUILDJyG DA AP zkEVIEWED BY: IN IAL: D E: 1 ST REV 1111ffl JA PLANNING 2ND REV BUILDING PUBLIC WORKS PUBLIC UTILITIES FIRE DEPT. PUBLIC SAFETY 3RD REV 0 111 Return this form to the Building Department once you have entered your comments into the AS400. 3. 29•D :1 �.� t4 " •5.ts14r , r ✓rpt•. s CITY OF ATLANTIC BEACH, PERMIT CALCULATION SHEET Date 0 la PermitNumber Address Ica - ►` Li Contact Name* Phone Heated Square Footage l(d 1:5� @ $ per sq ft=$ Gange4 r*l- 220Y @ $ persgft=$ Ca�pexl-fS"'h @ $ Per sq ft=$ ' Deck @ $ per sq ft=$ Patio. @ $ per'sqft=$ TOTAL VALUATION: $ Tote Valuation Remaining Value $ per thousand or.portion threof CONSTRUCTION TYPE: TOTAL BUILDING FEE $ ZONING: +% Filing Fee $ FLOOD ZONE: ( }Fireplaces Aja. $35.00 $ IMPERVIOUS SURFACE: fA l AB CONSTRUCTION SURCHARGECAPITAL yE*ncD CM"MON SURCAGE If $�I Pvl- SECTION H IMPACT FEE $ Y 1 SEWER IMPACT FEES $ AZ 1A PALST CONSTRUMON SURCHARGE 22cs $ Wf b STATE RADON SURCHARGE $ 7. 9 �+ WATER CONNECT/hOMR,ONLY?S $= WATER CONNECT/TAP&METER $ AJIA WATER CROSS CONNECTION $ WATER IMPACT FEE $ OTHER S +GRAND'TOTAL DUE: $ 1/13/63 BUILDING PERMIT APPLICATION =' pw CITY OF ATLANTIC BEACH �j •` 800 Seminole Road,Atlantic Beach FL 32233 Office: (904)247-5826 ■ Fax: (904)247-5845 Job Address: 561D / /QCT 1,q-X7)jX6, &,Q). • 3-2233 Permit Number: Legal Description r;�u g p lu�r© idL� 7 S �� ,tit l� ✓nlsyyP ,5&,rWd0,-1e—z- C�ry_oG �f�4G, i✓n/J� T •C �fl�i' ��r✓NC. C�c>. �Z-ex r7 �V aluation of Work(Replacement Cost) $ 6O °D Class of Work(Circle one): 1. Addition Alteration Repair _ Use of existing/proposed structure s) (Circle one): Commercial Residential ■ If an existing structure, is a fire sprinkler system installed? (Circle one): o N/ ■ Is approval of homeowner's association or other private entity required? (Circle one): es No Describe in detail the type of work to be performed: 11 e Property Owner Information ,�� �,� � Name: f1VAC }icl�nl�t/uh C'�,P� /% i�� �vTAddress: 24,K P, City States Zip Phone Contractor Information: Name of Company: &1 --At 60X, l�C:«.CS=?ieQualifying Agent: Address: City11iL,�7-1C / fl State F Zip �Z '- Office Pi,),/ " � �(�� Job Site/Contact Number State Certification/Registration# �' C� ''o' �' �`l� Office Fax #� C,7/-A Y/- V�,A " Architect Name & Phone# /-eez-t- - 717 (,3 --<?�I& Engineer's Name & Phone # ..%- lz�;jl/)? L 1162-4.5 1041- U Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to thi issuance of a permit and that all work will be performed to meet the standards o fall laws regulating construction in this1'urisdiction. This permit becomes null am void if work as not commenced within six(6)months, or if construction or work is suspended or abandoned for a period ofsix(6)months at any time after work i, commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers,Heaters,Tanks and Ai. Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOL INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING OUR NOTICE OF COMMENCEMENT. I hereby certi� that 1 have read an e i d this application and know the same to be true and correct. All provisi4ofland ordinances governing this p+ ofwork will be complied with whet e i ed herein or not. The granting of a ermit does not presume to give autolate or cancel the provisions ojan, other federal,state, or local law r i onstruction or the performance ojconstruction. Signature of Property Owner: Signature of Contractor: Sworn t and subscribed beP7� fore Sworn to and subscri this VW Day of MR"t' 2O� this Day of Notary Public: Notary Public: RY » ro�P Gey Beverl J. Jones ��;r+r"• Stacey Brooks Commission#DD567168 � = MYCOMMISSION# DD240262 EXPIRES ,� ��o Expires September 3,2010 "�• J® `� AU9U9t t 2DU7 + Bonded Troy Fain•Insurance.Inc 8 r 00.385.7019 ''Foifkd;.� BONDED THRU TROY FAIN INSURANCE,INC DO NOT WRITE BELOW THIS LINE: OFFICE USE ONLY review Result(Circle one) FORM 60OA-2004R EnergyGauge®4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: villa5810 Builder: RPC Address: 58010 Fleet Landing Blvd. Permitting Office: City, State: Atlantic Beach, FL 32233- Permit Number: Owner: Jurisdiction Number: Climate Zone: North 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap:39.4 kBtu/hr _ 3. Number of units,if multi-family 1 - SEER:21.00 _ 4. Number of Bedrooms 2 _ b.N/A _ 5. Is this a worst case? No _ 6. Conditioned floor area(W) 1670 ft2 _ c. N/A 7. Glass type and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble,U--0.4)212.7 ft' _ a. Electric Heat Pump Cap:39.4 kBtu/hr b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear)212.7 W _ b.N/A 8. Floor types a. Slab-On-Grade Edge Insulation R=2.0,126.0(p)ft _ c. N/A b.N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=21.0, 1000.8 W _ EF:0.94 _ b.Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A c. N/A d.N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 ft2 15. HVAC credits PT,CF, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts - PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,80.0 ft MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.13 Total as-built points: 13479 PASS Total base points: 20822 I hereby certify that the plans and specifications covered by Review of the plans and -f%E sT this calculation are in compliance with^Florida Energy specifications covered by this 04 Code. �r ' calculation indicates compliance PREPARED BY: / Y r � with the Florida Energy Code. ry !!11 •• E -,`. DATE: /67 Before construction is completed 0 this building will be inspected for 0 a 1 hereby certify that this building,as designed, is in compliance compliance with Section 553.908 with the Florida Energy Code. Florida Statutes. �YcoD yvi3'i��y'S OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) FORM 60OA-2004R EnergyGauge®4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points .18 1670.0 18.59 5588.0 1 1.Double,U=0.45,Clear SW 1.0 1.0 150.2 42.20 0.49 3108.0 2.Double,U=0.45,CIear NW 1.0 1.0 52.5 28.18 0.64 944.0 3.Doubie,U=0.45,Clear SE 1.0 1.0 10.0 44.78 0.49 221.0 As-Built Total: 212.7 4273.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 142.2 0.70 99.5 1.Concrete,Int Insul,Exterior 21.0 1000.8 0.17 171.6 Exterior 1000.8 1.70 1701.4 2.Concrete,Int Insul,Adjacent 21.0 142.2 0.17 24.4 Base Total: 1143.0 1800.9 As-Built Total: 1143.0 195.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 2.40 50.4 1.Adjacent Wood 21.0 2.40 50.4 Exterior 42.0 6.10 256.2 2.Exterior Insulated 21.0 4.10 86.1 3.Exterior Insulated 21.0 4.10 86.1 Base Total: 63.0 306.6 As-Built Total: 63.0 222.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM= Points Under Attic 1670.0 1.73 2889.1 1.Under Attic 22.0 1670.0 2.11 X 1.00 3523.7 Base Total: 1670.0 2889.1 As-Built Total: 1670.0 3523.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 126.0(p) -37.0 -4662.0 1.Stab-On-Grade Edge Insulation 2.0 126.0(p -38.53 -4855.2 Raised 0.0 0.00 0.0 Base Total: 4662.0 As-Built Total: 126.0 -4855.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1670.0 10.21 17050.7 1670.0 10.21 17050.7 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 I FORM 60OA-2004R EnergyGaugeO 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT Summer Base Points: 22973.3 Summer As-Built Points: 20410.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Paints) (DM x DSM x AHU) (sys 1:Central Unit 39400btuh,SEER/EFF(21.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 20411 1.00 (1.09 x 1.147 x 1.00) 0.163 0.902 3742.9 22973.3 0.3250 7466.3 20410.7 1.00 1.250 0.163 0.902 3742.9 EnergyGaugeTm DCA Form 60OA-2004R EnergyGaugeVFlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL, 32233- PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point .18 1670.0 20.17 6063.0 1 1.Double,U=0.45,Clear SW 1.0 1.0 150.2 4.69 1.60 1125.0 2.Double,U=0.45,Clear NW 1.0 1.0 52.5 12.05 1.02 648.0 3.Double,U=0.45,Clear SE 1.0 1.0 10.0 2.73 1.94 52.0 As-Built Total: 212.7 1825.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 142.2 3.60 511.9 1.Concrete,Int Insul,Exterior 21.0 1000.8 1.73 1730.0 Exterior 1000.8 3.70 3703.0 2.Concrete,Int Insul,Adjacent 21.0 142.2 1.56 221.4 Base Total: 1143.0 4214.9 As-Built Total: 1143.0 1951.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 11.50 241.5 1.Adjacent Wood 21.0 11.50 241.5 Exterior 42.0 12.30 516.6 2.Exterior Insulated 21.0 8.40 176.4 3.Exterior Insulated 21.0 8.40 176.4 Base Total: 63.0 758.1 As-Built Total: 63.0 594.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1670.0 2.05 3423.5 1.Under Attic 22.0 1670.0 2.45 X 1.00 4091.5 Base Total: 1670.0 3423.5 As-Built Total: 1670.0 4091.5 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 126.0(p) 8.9 1121.4 1.Slab-On-Grade Edge Insulation 2.0 126.0(p 12.47 1570.8 Raised 0.0 0.00 0.0 Base Total: 1121.4 As-Built Total: 126.0 1570.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 1670.0 -0.59 -985.3 1670.0 -0.59 -985.3 EnergyGauge®DCA Form 60OA-2004R EnergyGauge®/FlaRESTOWR FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT Winter Base Points: 14595.6 Winter As-Built Points: 9047.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Electric Heat Pump 39400 btuh,EFF(8.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0 9047.7 1.000 (1.069 x 1.169 x 1.00)0.426 0.950 4578.4 14595.6 0.5540 8086.0 9047.7 1.00 1.250 0.426 0.950 4578.4 EnergyGauge""DCA Form 60OA-2004R EnergyGaugeVFlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd,,Atlantic Beach,FL,32233- PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 40.0 0.94 2 1.00 2578.94 1.00 5157.9 As-Built Total: 5157.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water - Total Points Points Points Points Points Points Points Points 7466 8086 5270 20822 3743 4578 5158 13479 PASS LT-�O.e � a tr rl, EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge4D/FIaRES'2004R FLRCSS v4.5.2 FORM 60OA-2004R EnergyGaugene 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 58010 Fleet Landing Blvd.,Atlantic Beach,FL,32233- PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area .5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at comers;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the to late. _ Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Mufti-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker electric or cutoff as must be provided.External or built-in heat trap re wired. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 oallons Der minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =90.9 The higher the score,the more efficient the home. 58010 Fleet Landing Blvd., Atlantic Beach, FL, 32233- 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:39.4 kBtu/hr - 3. Number of units,if multi-family 1 - SEER:21.00 - 4. Number of Bedrooms 2 - b.N/A - 5. Is this a worst case? No 6. Conditioned floor area(112) 1670 ft2 - c. N/A - 7. Glass types and area:(Label reqd.by 13-104.4.5 if not default) - a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a. (Dble,U=0.4)212.7 ft2 _ a. Electric Heat Pump Cap:39.4 kBtu/hr - b. SHGC: HSPF:8.00 - (or Clear or Tint DEFAULT) 7b. (Clear)212.7 ft2 _ b.N/A - 8. Floor types - a. Slab-On-Grade Edge Insulation R=2.0, 126.0(p)ft _ c. N/A - b.N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons - a. Concrete,Int Insul,Exterior R=21.0, 1000.8 ft2 _ EF:0.94 _ b.Concrete,Int Insul,Adjacent R=21.0, 142.2 ft2 _ b.N/A - c. NIA _ - d.N/A _ c. Conservation credits - e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=22.0, 1670.0 ft2 - 15. HVAC credits PT,CF, - b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. NIA _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Rei:Unc. AH:Garage Sup.R=6.0,80.0 ft _ MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building �4T8E ST9 h Construction through the above energy saving features which will be installed(or exceeded) __ p in this home before final inspection.Otherwise,a new EPL Dis la Card will be completed P P Y P ani 4g ' based on installed Code compliant features. Builder Signature: Date: > Address of New Home: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLAIRES computer program. This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPAIDOE EnergyStarTmdesignation), your home may qualify for energy efficiency mortgage(EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on ages 2&4. EnergyGauge®(Version:FERCSl v4.5.2) Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Class 3 Rating 58010 Fleet Landing Blvd. villa5810 Registration No. 0 Atlantic Beach, FL 32233- Climate: North 6/1/2007 Building Loads Base As-Built Summer: 22973 points Summer: 20411 points Winter: 14596 points Winter: 9048 points Hot Water: 4848 points Hot Water: 4848 points Total: 42417 points I Total: 34307 points Energy Use Base As-Built Cooling: 7466 points Cooling: 3743 points Heating: 8086 points Heating: 4578 points Hot Water: 5270 points Hot Water: 5158 points Total: 20822 points Total: 13479 points PASS e-Ratio: 0.65 EnergyGauge®(Version: FLRCSB v4.5) f, j/lj'' CITY OF ATLANTIC BEACH 800 SENIINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 r J1 INSPECTION EMAIL REQUEST: Building deptkwab.us Application Number . . . . . 07-00001271 Date 9/11/07 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc INSTALL GEOTHERMAL HP ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PENINSULAR MECHANICAL CONTRACTORS INC P.O. BOX 8116 MADEIRA. BEACH FL 33738 (727) 573-4822 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 69 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 69 . 00 69. 00 . 00 .00 Plan Check Total . 00 . 00 . 00 .00 Grand Total 69. 00 69. 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. SEP-11-2007GUE) 10:25 Peninsular Mechanical Contractor (FAX)727 572 0978 P. 002/003 CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION Date: Property Address: Owner: N ecr zy(:, 17oR rt Lar L*AJD>&X- Telephone#: Contractor: ME-" ��%%1'�� Telephone#: -727-X79 Contractor Address: I a!o 9 a ( doS�d a 4, I U t7 Fax#: -7 Z 7-572 097 Gt.r✓ t Contractor Signature: In comidemtion of pemrit given for doing the work ac dcactr d in the above statement,we hereby agra to perform said wort:in accordanl:c with the attached plans and speeificalious which are apart hereof and in accordance with the City of Atlantic Hench ordinances and standards of rxrd practicc listed therein. Type of Heating Fact: Irother construction is being done on this building or site,list the building permit number: U Electric U Gas: _1.13 _Nulurd —.Central Utility U Gil JC Other-1 eCil �-ECi 7-H c!2M�u MECHA ICAL TQURNENT TO BE INSTALLED NATURE OF WORK 1X I lent _Space _Recessed central _Floor el ltesidenliul Air Conditioning: _Room '_Central T' Duct Systcm: Matethal it6 r t°7�F,(laicknctis Zl.?CsF1 O Commercial Maximum capacity %SOD elm U Refrigeration U New Building U Cooling Tower:Capacity Rpm p Existing Building O vire Sprinklers:Number of Heads O Elevator: __ Manlitl Escalator (Number) 13 Replacement of Existing System * Gasoline Pumps­ (Number) o Tanks (Number) New Installation U LPG Containers (Number) (No system previvusly installed) U Unwed Pressure Vessel G Extension or Add-on to Existing System C) Boilers U Gas piping U Other-Spcciry„- O Other-Spcci fy, _ LIST ALL E UMMF.NT AIR CONDITIONING.REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Dcseription Model N Manufacturer 'fon`x Agency ttEATtNC—FURNACES.BOILERS.FlAXPtaCES&AIR HANDI,F.R'S Approving Number Units Description Model a ManW'acturcr 11'111's Ageney TANKS Non+inalCapaciiy Type Liquid %trial Approving [low Maim &Dirmnsrons ('retained Manul'saurcr Nu. Aga c w 800 Seminole Road-Atlantic Beach.Florida 32233-5445 Phone:(904)247-5800- Fax: (904)247-5845 a help:M=w.cLatlnntic-heaeh_tl.0Revised 1/04 CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 4 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-deptna coab.us Application Number . . 07-00001062 Date 7/25/07 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description ROOF Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 12000 -----------------7-------------------------------------------------------- Application desc INSTALL TILE ROOF ------------------ ---------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- PROFESSIONAL SUNSHINE ROOFING 1017 IRELAND DR DELTONA FL 32725 ---------------------------------------------------------------------------- Permit . . . . . . ROOF PERMIT Additional desc . . Permit Fee . . . . 55 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 12000 Expiration Date . . 1/21/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 55 . 00 55 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 55 . 00 55 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION 4- CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach FL 32233 Office: (904)247-5826 • Fax: (904)247-5845 Job Address: f �/ l r� �[ Permit Number: Legal Description Valuation of Work(Replacement Cost) S ;26/&9z ■ Class of Work(Circle one): a Addition Alteration Repair ■ Use of existing/proposed structure s Circle one): Commercial entia ■ If an existing structure, is a fire sprier system installed?(Circle one): o N/A ■ Is approval of homeowner's association or other private entity required?(Circle one): Ys No Describe in detail the type of work to be performed: / ,,fin st< j/ � �fu u�.�r l•� ,�t/���t � ?��.��I a.,��`t�fir ;�"/� �t�C�1� Property Owner Information Name: Address: City State_Zip Phone Contractor Information: Name of Company: 1,reAy a f f� 4 g Agent: Address: CityIle mla State Zi Office Phone --1!jy ,d tW Job Site/Contact Number State Certification/Registration# C�',n 4!°� Office Fax# O Architect Name &Phone# Engineer's Name&Phone# Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced rior to the issuance o f{a ermit and that all workwill be erformed to meet the standards of all laws regulating construction an this jurisdiction, 7`his permit becomes null and void if work is not commenced within six(6) months, or if canstruction or work as suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate ppermits must be secured for Electrical Work, Plumbing, Signs, Fells,Pools, Furnaces,Poilers,Heaters, Tanks and Air Conditioners, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COlV T/IENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR. IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF CONY NIENCEMENT. thereby certify that have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. grantini ra permit does not presume to give authority to violate or cancel the provisions of any other,, deral, st or loca w regulating construction or the performance of construction. Signature of Property Owner: Signature of Contra Sworn to and subscribed before me Sworn to and subscribed before me this_Day of this Day of Notary Public: Notary Public: REVISED 03.05.07 4000 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD `- ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-dept&coab.us Application Number . . . 07-00000830 Date 6/18/07 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc hvac hookup --------------------- ------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- AMERICAN ELECTRICAL CONTRACTOR Q/A:GRASS, ROBERT 5065 ST. AUGUSTINE RD. #3 JACKSONVILLE FL 32207 (904) 737-7770 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/15/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. lir CITY OF ATLANTIC BEACH x 4 ELECTRICAL PERMIT APPLICATION Date: nap_Property Address: 90, Owner: Telephone#• Contractor: n M E Fi Ci(NN E I W-F IC14� L1`a�l Telephone #: 3 Contractor Address: 1'n Fax #: —72Q- t�q9 Contractor Signature: �Y� C-Z In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: ❑ Trailer Service: If other construction is A New Residence ❑ Temp. New being done on this building Or site,list the building ❑ Old ❑ Commercial ❑ Signs ❑ Increase pe�rm�. n�umb ❑ Re-wire L3 Addition Sq.Ft. La Repair t r i- Conductor Size: AMPS: COPPER ALUMINUM Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service RACE Size AMPS PH W VOLT WAY Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P. RATING CEILING KW-HEAT Conditioning COMP. MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER-] H.P. PHS UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon_Transf. Ea. Si n Miscellaneous _ 800 Seminole Road •Atlantic Beach, Florida 32233-5445 Phone: (904)247-5800. Fax: (904)247-5845• httn://www.ei.atiantic-beach.fl.us Revised 1104 t S CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD :r ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-deptocoab.us Application Number . . . . . 08-00000047 Date 1/14/08 Property Address . . . . . . 5810 FLEET LANDING BLVD Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------------------------------------- Application desc EARLY POWER FEE ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ R. P.C. GENERAL CONTRACTORS 248 LEVY RD ATLANTIC BEACH FL 32233 (904) 241-4416 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 300 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation 0 Expiration Date . . 7/12/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 300 . 00 300 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 300 . 00 300 . 00 . 00 . 00 PERMIT'I&APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA BUILDING CODES. JAN-11-2009 11•:10 AMERICAN ELECTRICAL CONT 7371099 P.01/01 j. � JAN 1 1 2008 A POWER OWER GREEMENT & RELEASE B Y.--_ s> .� CITY OF ATLANTIC BEACH Floctric power is requested now under the conditions and farms of this&W executad Agreement&Release Job Address: PesmitNo. I"— C CCX>Q.UAA Service'ype(Clyde One): Overhead Underground Wig,the undersigned General Contractor and Electrician,understand and agree: I. "Early power" is areltiy for our construction oonvojeoce, it is not required by Codes and does rco substitute for Final'' -P6ctions 0r the C/ (Cert' cite of OempancyTT t must be issued before occupancy, and as such is at the discretion of the Buidrng Acial. 2. T.hs City of Atlantic Beach will make a special inspection prior to the early power energizing. All rough inspec6ons must have prior Approval,including meter base connectiotis, 3. Occupancy or use of the new constriction before a formal C/O constitums fraudulent use of the early electne service. Sucb, action is expressly pno.ibited and penalized by The City of, q I=tjo Res Ordinanom. A viaMon of this Agen==t sh"rosult in a,request fur prompt removal of electric service after at twenty-four hour notice. 4. "Early Powq"ralaasa authority is the Eleotrieian and/or the Contractor and must not ocout before: a. Equipment;devices and 6xtur"are installed(or blanked o�sanely. b. Panel is complete with breakers and cover an (labeling required A final inspectioo), C, Service connection and grounding is eolztp'1 e. d. The electric systmo has k&ly passed throng electrical check. o. Meter can is permdnentlyy marked witch dress. f. Temporary address numbera displayed((permanent numbers are required for C/O). S,.' Pay$300.administration Fee,any reisispoetioa fees amd any outstanding requirements must be satisfied prior to release. 6. This fully completed form is to be submitted to the Building Department by hand,mail or fax.. 7. Future melt Agree .eats 11 oot be accepted from those who violate anyone of the above items, C-0WRACT011. DATE PRINT NAME ELECTRICIAN DA'[p f o PRINT NAME 800 5emiaoleRoad,A,tiautic Beach FL 32233 Phone!(904)247-5826 Fax!(904)247-5845 htwWwww coab,us revised 11,29,06 TOTAL P.01