Permit Mech 1371 Linkside Dr 2010 CITY OF ATLANTIC BEACH S IB 800 SEMINOLE ROAD ' 4 ATLANTIC BEACH, FL 32233 .a ::*1 ! `e ^ / i INSPECTION PHONE LINE 247 -5826 ' 4 0,111 Application Number 10- 00001405 Date 11/22/10 Property Address 1371 LINKSIDE DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc lcu lahu Owner Contractor ARMSTRONG, PATRICIA CHAPPELL HEATING & AIR 6451 BEACH BLVD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32216 (904) 724 -1344 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 5/21/11 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / 3 7/ l I" " 1 )) e-- pi PERMIT # PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INS # ONE Air Conditioning: Unit Quantity / Tons Per Unit REQ RED Olt Heat: Unit Quantity BTU's Per Unit Seer Rating S -�— Duct Systems: Total CFM QUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisio s of any other state or local law regulation construction or the performance of construction. Property Owners Name ?ht Aril) � /C> Phone Number Mechanical Compan A / , e- / / � 7 ! A Office Phone Fax Co. Address: (9TC" . G n V 1) City ,,.5 Statej( Zip3,2Z J6 License Holder (Print)/ e AA '`/ to - Ce 'fication/' ey' tration —U(D SA Notarized Signature of License Holde/ • �'I I Al f A F O' 1 #k --G / Sworn and subscri before • e 4 's' :! day 7.f dV 20 /' Signature of Notary Public _�k.._.oi �2.. 1 , V — f L,�A This combination qualifies for a Federal Energy ti RI CERTIFIED TM E fficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2010. www.ahridirectory.orq Certificate of Product Ratings AHRI Certified Reference Number: 3519775 Date: 11/22/2010 Product: Split System: Heat Pump with Remote Outdoor Unit- Air- Source Outdoor Unit Model Number: 4TWR5036E1 Indoor Unit Model Number: 4TEE3F39A1 Manufacturer: TRANE Trade /Brand name: XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2006 for Unitary Air- Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 36000 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 34000 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 23600 *Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Crtificate and The co of this Certificate ate may not, in e whole or part, be reproduced; ' coped; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION ��r Air- Conditionin He a ti ng, The information for the model cited on this certificate can be verified at www.ahridirectory.org, 11111 -' click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on and Refrigeration g, Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. CERTIFICATE NO.: ?29349187998435477 ©2010 Air- Conditioning, Heating, and Refrigeration Institute