Loading...
1999 Selva Marina Drive 2010 Pool III II III � II I GENERAL DESIGN REQUIREMENTS: -Slides shall meet the manufacturer's installation requirements. -Entry/Exit:required at the shallow end&at the deep end if over 5'deep.Acceptable are stairs(10" minimum tread with 240 square inch min.area 12"max riser with intermediate treads&risers uniform). Ladders underwater seats,&swim outs will be max.20 inches below water. I -Circulation systems,components&equipment ment shall comply with NSF 50. -The maximum turnover rate is 12 hours. Return Line -Filters shall have an air release andau ressure e. p gauge. -Pumps 3 hp&less shall meet ANSI/UL 1081 corrosion resistant with strainer&meet the required flow. -Surface skimmers shall meet NSF 50&there shall be one for every 800 sgft of surface area. 6'Spa+12" -Return inlets shall be a minimum of one for every 600 sgft.of surface area. -Heater shall meet ANSIZ21.56 or UL 1261 or UL 559. -Disinfectant equipment shall comply with NSF 50 -Pressure test piping at 15 psi for 30 minutes or meet local code if greater. 12", II I I Special Spa Requirements -Maximum water depth=4 feet&Maximum seat depth=28 inches eturn Line -Floor Slope 1.12 Steps: min tread 10"x 12" 7"minimum riser with 12"maximum riser except the bottom step may be 14" anning Ledge if it is the seat. r4r -Intermitently it shall have 1 hour turnover.If continuous a 6 hour turnover. Umbrella Sleeve -Maximum temperature to be 104 degrees. -Meet ANSI/NSPI Article XVII safety instruction/safety signs Pool Steps -Pressure test piping at 25 psi for 30 minutes or meet local code if greater. I Return Line Electrical Requirements Cleaner Line -Wiring and bonding&all electrical to NEC Art.580 or Local Code I -No outlet or overhead power within 10'if within 15'protect by GFI -Transformers min 10'from pool 8"above water,I box 4'from pool brass to)box or transformer,which ever is first except where PVC is approved Florida Building Code 424-2 The pool contractor is responsible for furnishing all detail design requirements for each individual pool in accordance with the Florida Building Code &all construction shall meet all appicable codes including plumbing electrical and gas Piping shall be sch 40 PVC NSFpw,Max pressure velocity 10 FPS suction 6 FPS The pool plan shall show the design plumbing as per the sample with the information required, shown.Main Drain plumbing shall be two drains seperated by 3'with approved ANSI/ASNE A112.29.8M AHentiC Beach covers As an alternate the approved drains may be placed on different plains. The two drains shall have j�� a common suction line. Suction grates may be used if approved at a maximum of 1.5 FPS&the suction piping is recessed from the grate the distance equal to the suction pump size In addition a safety fSOntpRanpe 1Mlt♦1 apPICabHt vacuum release system must be installed.This ma consist of an air release system. The vent pipe shall be n and Other localland tied to the main drain lines,sized the same as the main drain suction line&brought back to the filter for protection&labeled"Safe Vent". As an alternate the dna,but does con location,elbowed up and over with a grate p ct "Safety nOa pelni sante Safe Vacuum Release System SVRS may be an approved valve meeting IAPMU IGC 160-2001a. §deland aN Compliance Safety v ( ) v pp g Oft Oftr app b� Skimmers do not require protection&may be designed for 30 GPM suction The following shall be labeled namVMQ n�ui with red label marker tape at the filter location: pipes,valves,"Safety Vent"or"Safety Device"& pump(s) r O 9110 City Of OC Off switch.Main Drain covers will comply with ANSI/APSP-7 suction entrapment avoidance standard. ata kali It has been certified that these design requirments are compliant with the Florida 2007 Building Code 424-2 ANSI/APSP 2007 standard for permanantly installed Spas&ANSI/NSPI-7 2007 standard for residential in-ground swimming pools I Pool Specifications Spa Specifications Additional Specifications Additional Notes �I I I III II II gth:30' -ength: 6 Round Gas Tank By: Others dth: 15' • h I Nidth: Vented By.Others pth:3.5'to 6' Electrical By:Clift&Co. DOORS AND WINDOWS TO imeter:89 Ln Ft Depth: Timer: Easy Touch 4 function Controller POOL AREA TO BE ALARMED TO ping: Pieces Coping: w/wireless remote CODE. k Sq Ft: 1032 sq.ft.inc,Lanai Jertical Material: Skimmer(s); 1 Size 2" ter Feat Interior Material: Main Drains: 2 Size 2" Return Lines: 4 Wall Returns Area around P001 Area Will be ter:Shares Spa Water Feature:Spillover Stnd-Lighting: Pool; 1 White Light Screened to Code. p Size: 2.0 Pentair Whisper Flow Chlorinator: Pentair Salt Yes IC-40 Pump Size:Shares PoolDeck By: Clift&Co. All barrier codes Will be islet. er Type: 200 sq.ft.Clean&Clear Heater:400,000 BTU Gas Heater Deck Drainage:Away from Pool I I I Surface: 467 sq.ft. II li