Loading...
Permit Add Fire Alarm 2010 �`‘ CITY OF ATLANTIC BEACH 5, ► ` � y 800 SEMINOLE ROAD _ '' z ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 4 r).1119 Application Number 10- 00001458 Date 12/17/10 Property Address 1 OCEAN BLVD Application type description ELECTRIC ONLY Property Zoning COM GENERAL DISTRICT Application valuation . . . 0 Application desc addition to existing fire alarm Owner Contractor ASHFORD ATLANTIC BEACH LLP LIFE SAFETY DESIGNS INC C.O EASLEY MCCCALEB & ASSOC 3038 LENOX AVE 431 E HORATIO AVE SUITE 120 JACKSONVILLE FL 32254 MAITLAND FL 32751 (904) 388 -1700 Permit ELECTRICAL PERMIT Additional desc . ADDITION TO EXISTING FIRE ALAR Permit Fee . . . 90.00 Plan Check Fee . . .00 Issue Date Valuation . . . . 0 Expiration Date . . 6/15/11 Other Fees STATE ELEC DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 90.00 90.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 94.00 94.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. UFE OEAFEI.Y ID lE S II Q MI S WWW.LI FESAFETYDESIGNS.COM SUBMITTAL DATA FOR ONE OCEAN ATLANTIC BEACH, FLORIDA JOB No. 2102651 NOVEMBER 8, 2010 ELECTRICAL CONTRACTOR: STILES ELECTRICAL TABLE OF CONTENTS: I FIRE ALARM MANUFACTURERS CATALOG DATA DESCRIPTION MANUFACTURER PART# PAGE# a) ADDRESSABLE MANUAL PULL STATION SILENT KNIGHT SD500 -PSDA 1 -2 b) PHOTOELECTRIC SMOKE DETECTOR SILENT KNIGHT SD505 -APS 3-4 c) DUCT SMOKE DETECTOR SILENT KNIGHT SD505 -DUCTR 5 -6 d) ADDRESSABLE RELAY MODULE SILENT KNIGHT SD500 -ARM 7 -8 e) SPEAKER/STROBE SYSTEM SENSOR SPSW 9 -12 o� 64 Jk "' l —l� L v Ran 4 1 ;(° - --°c- II 1�D1NG�U Cf 5 7 ill 3038 LENOX AVE. • Jacksonville • Florida 32254 • 904- 388 -1700 • Fax 904- 388 -1718 FL — EF000878 FL CONTRACTOR 1 — 13235500011993 GA — 1V0004677 INTELLIKNIGHT ACCESSORY 1 S D500 -PS and SD500 -PSDA Addressable Pull- Station ' --.?) y IntelliKnight's addressable pull stations combine fast response with p pin -point , location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA • Corrosion - resistant gold - plated I contacts. 4 PULL 4 Addressable Pull • Reflective label makes it easier 1 Station to locate in low light The SD500 -PS is a single action Operation it g* d �_ addressable fire pull st ation, and t P . ,,„- � ... the SD500 - -PSDA is a dual action pull stations are operated by a pull 1 The SD500 -PS /PSDA single action ,. � addressable fire pull station. The on the front pull cover of the SD500 -PS /PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable , on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs; panel. The SD500 -PS /PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset t a t ,I R , 1 explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold - plated to avoid relocking the station with a reset - key. The reset keys are the same - a -I risk of corrosion. The SD500- ke Y Y ��tt'; PS /PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500 -PS /PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32 °F to 120 °F • UL Listed communicating with the loop. The (0 00 to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS -SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications available Operating Voltage: 24VDC 0 S1LI NT Standby Current: .55mA • Terminals - accept up to 14 Alarm Current: .55mA tO` gauge wire 6, A Piwortottewott i INTELLIKNIGHT ACCESSORY II SD500 -PS and SD500 -PSDA Addressable Pull- Station ,,'.... ._ .t . Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. P '1 � ii i ' I . V .INtSii . / ' 's ,, ,,,, , h 7,---: �� c w t� � � �.,. 1+ ' ztm�as�c +msnc r t - .., _ ,. ,.. , . ,.., ,,„,,,,,, , , , ,,,. ..,.. , , ,: Wiring -'- ' , , 1 - l 2,412- 1 Mounting to Single Mounting to Optional Surface Mount Box Gang Electrical Box, „ k 5tdt�f` ; SD500 -PSDA ,, } WIR 3A- 1 5 LIFT ry' . f L r M.... , ' ` far �1 _ ._ ° i Eloctricai Bc* rust be Installing SD500 -LK Dimensions etc ast14f2"Deep SILENT KNIGHT d o 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800- 446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http: / /www.silentknight.com Copyright © 2003 Silent Knight 02 INTELLIKNIGHT ACCESSORY Addressable Photoelectric Type ,, Smoke Detector - Detect smoldering fires quickly and get T help fast with IntelliKnight® photoelectric . smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS The light received is converted into Analog / Addressable an electronic signal. Under normal Aii Photoelectric Type conditions, the status LED blinks , � ,. Smoke Detector approximately every 15 seconds, The SD505 -APS is particularly indicating that the head is suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the i such as soft furnishings, plastic, alarm period. k , " i foam or other similar materials F which tend to smolder and produce Features large visible particles. Low profile, 2 inches, including ,SD505 -APS Smoke Detector base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 -41 VDC compensation for contamination without mechanical switches and a simple detector calibration Current Consumption: • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the Built-in fire test feature Alarm: .55 mA WindowsTM based downloading Ambient Temperature:32°F ° software). • Simple detector calibration perature:32 F to 120 F testing through the control panel (0 °C to 49 °C) Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable from the pulsing light source. In the Air Velocity: 0 - 300 FPM • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505 -6AB detector and light is reflected from CSFM approved (Sold Separately) (6" Base) the smoke particles to the receiving SD505 -4AB element. • MEA approved (4" Base) • FM Approved SILENT KNIGHT by Honeywell INTELL!KNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type Smoke Detector , Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. N Diameter = 5- 15/16" N Diameter = 3- 15/16" It el 0 _h _ m / 4i o 4 / � i ~ ( CD " . -- " l including base � � e , I € e Height = 2 inches, � � � � �� f � j JJ / \\,,,, , a , xrncarr a Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) El SILENT document is not intended to be used for installation purposes. We try to MADE IN AMERICA FORM# 350225 Rev C,. 05/05 KNIGHT keep our product information upt -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. L/ INTELLIKNIGHT© ACCESSORY Model SD505 - DUCTR Duct Detector Housing with SD505 -APS Analog Photoelectric Smoke Sensor and Relays Model SD505 - DTS - K Remote Test Switch. Detect smoke in air handling systems and prevent re- circulation with Silent Knight's addressable duct smoke detector Analog Duct Smoke Detector with Relay Module and Remote Test Switch The SD505 -DUCTR Addressable duct smoke detector provides early detection of smoke and products of combustion present in air moving through an HVAC "' duct to prevent re- circulation of smoke into the air handling system. The SD505 -DUCTR is a heavy duty metal housing with a pre - installed SD505 -APS Analog y'F Photo Electric Smoke Sensor and relay module. When �•_ smoke is detected in a duct, the unit communicates the condition to the IntelliKnight FACP. The built -in relay module, in tum, turns off fans, blowers, and other SD505-DUCTR devices. The SD505 -DTS -K is a remote test switch that is used with the SD505 -DUCTR so you can remote test the Duct Detector. It also provides LED indication of the status of the SD505- DUCTR. The SD505 -DTS -K uses the same key as the control panel. Features SD505 - DTS - • Two -wire connection to SLC • Detects and limits the spread of smoke • Rugged steel backbox with clear plastic cover Specifications Rating • LED alarm indication and communication on sensor head SD505 -DUCTR • No screens or filters to clean Alarm Relay Contact Rating 10A @ 24VDC • SD505 -APS Photoelectric Smoke Detector pre- loA@ llsvnc installed. 10A @ 240VAC • 3 standard tube lengths Trouble Relay Contact Rating 2.5A @30VDC • Large terminal connection screws Operating Voltage 24VDC • UL Listed Aux. Power Input Current 20mA Standby • CSFM 62mAAlarm • MEA 429 -92 -e Vol XI SLC Input Current 0.5mA Maximum SLS Resistance 50 Ohms Operating Temperature 32 °F - 100 °F Humidity 10% -85% RH Non - Condensing SILENT 7550 Meridian Circle, Suite 100 Air Velocity Rating 300 - 4000 ft. /min TO KNIGHT Maple Grove, MN 55369 Dimensions 91 /8'L x 71/4 "W x 21/4 "H 763 -493 -6400 or 800 - 328 -0103 Maximum Net Weight albs by Honeywell Fax: 763 - 493 -6475 www.silentknight.com Sampling Tubes 2.5ft., 5ft, or loft Intelliknight Accessory SD505 -DUCTR Duct Detector Housing — , with Relay Module and = Itttitiii, SD505 -DTS -K Remote Test Switch Engineering Specifications : i The Air Duct smoke detector with relay module remote test switch shall be Silent Knight module SD505 -DUCTR and SD505- DTS -K. The housing shall contain a Analog Photoelectric Smoke Sensor, Silent Knight model SD505 -APS. Alarm Relay rated at 10A @ 120/240 VAC and 24 VDC to control HVAC power. Module shall have separate LEDs that indicate normal or alarm condition. Module shall have a momentary key switch for testing of the duct detector. i H 1 � - -J -, I r - , , . . 4: 4 Class A (Style 6) Wiring A r; k I 8 i ti l r 4 r , F4 w SD505 -DUCTR and SD505 -DTK -K Wiring Connection '1 5 MiC r E r , i Class B (Style 4) Wiring E:1 SILENT This docu is not intended to be used for installation purposes. We try to keep » KNIGHT our product i nformat i on up-to-date and accurate. We cannot cover all specific Made in America application or anticipate all requirements. All specifications are subject to change by Honeywell without notice. For more information contact Silent Knight 7550 Meridian Circle, Suite 100, Maple Grove, MN 55369 -4927 Form# 350005 Rev A Phone: (763) - 493 -6400 or (800) 328 -0103, fax (763) 493 -6475 © 2009 Honeywell International Inc. www.silentknight.com INTELLIKNIGHT ACCESSORY ti SILENT Model SD500 -ARM KNIGHT Addressable Relay Module by Honeywell Place relay applications anywhere on the IntelliKnight loop with the SD500 -ARM Addressable Relay Module. The SD500 -ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500 -ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500 -ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. Model SD500 -ARM Features Addressable Relay • Two sets of Form C contacts. Module • Contacts are rated at 2A @ 30 The SD500 -ARM provides two VDC or .6A @ 120 VAC.'' Form C contacts rated at 2A 30 @ Up to 127 relays can be used on VDC or .6A @ 120 VAC. These each SLC loop. contacts can be used for virtually • Relay programming is any normally open or normally y y p y completely flexible —can be closed application. mapped to zone conditions. Model SD500 -ARM • Polling LED visible through Approvals cover plate. • UL listed, complies with Specifications NFPA 72. Operation • CSFM approved Each relay module is programmed Contact Rating: Form C • MEAApproved, 429 -92 -E, with a unique SLC loop address. 2A @ 30 VDC Vol. 9 When an event that controls the .6A @ 120 VAC • relay module occurs, the relay is FM approved triggered by the IntelliKnight panel. Standby Current: .55 mA Alarm Current: .55 mA Compatible Control Panels Ambient 32 °F to 120°F Temperature (0 °C to 49 °C) • 5820XL Mounting 4- square electrical box • 5808 • 5700 7 INTELLIKNIGHT ACCESSORY Model SD500 -ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500 -ARM. The modules shall be UL listed compatible with Silent Knight's Intelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW CAUTION REMOvE avE POWER PRIOR TO 5,. 3 .,t.t.? ; <.:i pITLO gL�eB�i I R ' L � k C 11[ .�. I r A�� "SQENT r \i i ':\1KDDQ3f I iir3�. 4 -7/8" 4 1/4" N M 1 " Model SD500 -ARM Addressable Relay Module Dimensions SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA 0 KNIGHT to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350218 Rev. D by Honeywell subject to change without notice. For more information, contact Silent ©2010 Hone y Knight 12 Clintonville Road, Northford, CT 06472 -1610. Honeywell International Inc. Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com 6-,M, SYSTEM SENSOR' /7 ._ Indoor 7 0,00'0 ittrt fon at 0471 e' araJrlt y r Output Speaker Strobes * and Dual Voltage , Evacuation Speakers w � r -` The new SpectrAlert Advance selectable output ,„ speaker strobes and dual evacuation speakers can reduce ground faults and allow faster installation. SPECT e / ^, • p Id y A N E Features The SpectrAlert Advance Series of speakers and speaker strobes Plug-in design is designed to reduce ground faults.The plug -in design allows the • installer to pre -wire mounting plates and dress the wires before • Protective cover isolates speaker components, reduces ground plugging in the speakers. The plastic cover prevents nicked wires by faults covering exposed speaker components. • Electrical compatibility with existing SpectrAlert products Field selectable candela settings on wall and ceiling units: This design also allows faster installations with instant feedback to • Standard: 15, 15/75, 30, 75, 95, 110, 115 ensure that wiring is properly connected, rotary switches to select High: 135, 150, 177, 185 voltage and power settings, and 11 field selectable candela settings for wall and ceiling speaker strobes. • Shorting spring on mounting plate tests continuity before installation The low total harmonic distortion of the SP speaker offers high • Rotary switch simplifies field selection of speaker voltage (25 and fidelity sound output while the SPV speaker offers high volume 70.7 Vrms) and power settings (' /,,'h,1 and 2 watts) sound output for use in high ambient noise applications. • Universal mounting plate for wall- and ceiling -mount units SpectrAlert Advance makes installation easy • Compatible with System Sensor synchronization protocol • Attach a universal mounting plate to a 4 x 4 x 2' /e inch back box . • SP speakers offer high fidelity sound output Flush mount applications are achievable without the need for an SPV speakers offer high volume sound output extension ring. • Connect the notification appliance circuit or speaker wiring to the • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 terminals on the mounting plate. candela • Attach the speaker or speaker strobe to the mounting plate by • No extension ring required inserting the product tabs into the mounting plate grooves. Rotate • Ceiling and wall mount application the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a • Optional tamper resistant Torx head screw included catch until it is secured with a captured mounting screw. Agency Listings SIGNALING T 4� ( ) ® MEA LISTED lI ,, approved 54048 7320 - 1653:201 1008 -E SpectrAlert Advance Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications � General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 2 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync - Circuit"'' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync - Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 °F and 120 °F from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177,185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual - voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature between 32°F and 120 °F. Speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps which are selected by rotary switch.The strobe shall comply with the NFPA72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync- Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 HzThe module shall mount to a 4 4"/16x 2'/8 -inch back box.The module shall also control two StyleY (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non - condensing Dimensions, Wall -Mount SPS Speaker Strobe 6.0 in L x 5.0 in W x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.0 in L x 5.0 in W x 4.9 in D (including lens and speaker) SP Speaker 6.0 in L x 5.0 in W x 2.8 in D SPSV Speaker 6.0 in L x 5.0 in W x 2.9 in D Dimensions, Ceiling -Mount SP5 Speaker Strobe 6.8 in Dia. x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.8 in Dia. x 4.8 in D (including lens and speaker) SP Speaker 6.8 in Dia. x 2.8 in D SPV Speaker 6.8 in Dia. x 2.9 in D Electrical /Operating Specifications Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm 8 to 17.5V (12 V nominal) or 16 to 33V (24 V nominal) panels with built in sync) Operating Voltage with MDL Sync Module 9 to 175V (12 V nominal) or 17 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power Y4, Y2, 1, 2 watts 605- 0424 -002 / 0 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 ft.) 2W 1W lh W V. W Wall -Mount SP Series 86 83 80 77 Wall -Mount SPV Series 90 87 84 81 Ceiling -Mount SPC Series 86 83 80 77 Ceiling -Mount SPCV Series 90 87 84 81 Wall -Mount SPS Series 85 82 79 76 Wall -Mount SPSV Series 89 86 83 80 Ceiling -Mount SPSC Series 85 82 79 76 Ceiling -Mount SPSCV Series 89 86 83 80 Dimensions 6.81 " 97� — 1.96 6.81 " 97" 1.84" 2.83" r 6.81" 10" 1.84" � n :: f f� ' ' t, j{ �+ w. s °� '' � u 1 i ...,,,!;.;%.. & - ' g ° ` ,i4.2:,,,,:, ...., . o'ss s .i, ......, t0 fs, .!: GS Ceiling Mount SPV Speaker Ceiling Mount SP Speaker Ceiling Mount SPS Speaker Strobe 5.00" .97=1 —1.84" 5.00" 2.83" 60 I X1.84" = [. „: 1 , ■ 5.98" I 5.97" _ 11- I) C i _ - II' El ro oc _ ,.� —� o a Wall Mount SP Speaker Wail Mount SPS Speaker Strobe A05 -0424 -002 /1 Surface Mounting 8 0. ` I k I I , , � , N 0 0� C °. I1��111,VA i - ~'C 111-..1 J ��� ■ Ceiling Mount Speaker with SPBBSCW Back Box Skirt Walt Mount Speaker Strobe with SPBBS Back Box Skirt Ordering Information for SpectrAlert Advance Speakers and Speaker Strobes Walt Mount White Red Description SPW SPR Speaker only SPWV SPRV Speaker only, High dB ,,,,• SPSW* SPSR* Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95, 110, 115) SPSWH* SPSRH* Speaker Strobe, Selectable Candela, High cd (135, 150, 177, 185) SPSWV* SPSRV* Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95, 110, 115), High dB Ceiling Mount White Red Description SPCW SPCR Speaker only SPCWV SPCRV Speaker only, High dB SPSCW* SPSCR Speaker Strobe, Selectable Candela (15, 15/75, 30, 50, 75, 95, 110, 115) SPSCWH* SPSCRH Speaker Strobe, Selectable Candela, High cd (135, 150, 177, 185) SPSCWV* SPSCRV Speaker Strobe, Selectable Candela (15,15/75, 30, 75, 95, 110,115), High dB SPSCWVH* SPSCRVH Speaker Strobe, Selectable Candela, High dB, High cd (135, 150, 177, 185) Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt SPBBSW SPBBS Wall Mount Back Box Skirt TRW TR Wall Mount Trim Ring TRCW TRC Ceiling Mount Trim Ring *Add -P to model number for plain housing (no'FIRE marking on the cover) e.g. SPSW -P �` '� ■ ST r1 Ei 3825 Ohio Avenue • St. Charles, IL 60174 e��R, ozooe5ntem5en�r. �'` SE SOR Phone: 800- SENSOR2 •Fax: 630- 377 -6495 current product Info JectmchangewMou[notice rystemsensmcwn(or �' \� \3 }' current t pr0dC1rf on" a ` b " °'°y '"e u[es`"e'y°"a["saam Shea` nos- az+- aoz -sroa• «[see /r7 City of Atlantic Beach APPLICATION NUMBER ,s i5 Building Department (To be assigned by the Building Department.) 800 Seminole Road la — / (f jaw � Atlantic Beach, Florida 32233 -5445 ! Q Phone (904) 247 -5826 • Fax (904) 247 -5845 / L,0". E-mail: building- dept @coab.us Date routed: /2/J3//? City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: / gefliil D ment review required Yes No C / Y 7)gisi Building_,,, Applicant: - 1 � Gy g Planning & Zoning Tree Administrator Project: / - T 0 r? 7 pj Public Works Public Utilities / frrr2 v$ ys / /f Publi afety ire Services. Roc- �' "`�dM ' �� � f �i rd� � ° av ��' a `� �' 9 A l G IIf 9�I � � p � (i ��i � � a� & f 4� ; �yt i,� , l a ( i (� p� °.a6h, a :` r% Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: Approved. DDenied. (Circle one -:j Comments: BUILDI PLANNING & ZONING Reviewed by: Date: / 2 "6S 4 0 TREE ADMIN. Second Review: DApproved as revised. DDenied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. DDenied. Comments: Reviewed by: Date: Revised 05/14/09 6 EXISTING TO REMAIN EXISTING TO REN • FIELD VERIFY FIELD VERIFY c - ADDRESS — ��- SP1 -4 ADDRESS RTU -3 � � � D A B c •. I S1 —a E A 3 0 R 1 ll©, I 1 • -_ � R A B C - c _ v E M REO G Q A WY 1 ©i, r. FIELD VERIFY SP155 E.O.L. S1 E D A D ADDRESS , 30cd E.O.L. SP1 A B,C A �� IE I AB, C FIELD VERIFY 0 J= ADDRESS I � ' '� E Al III111111111111111111111111 1 111111111111111111111111111tIiII11111111I I I IIIIIIIIII E MtETING au 'EOM 101 E. A,B,C E FIELD VERIFY E ADDRESS E 0 SP1 -3 S1 -3 A,B,C E A,B,C 30cd L IMIIIIIIMUMMIEMIIII1111111 ' i IIIIIIIIIIIIIIIIIIIIIIIIIINIIIIIIIIIIIIIIUIII! ADDRESS FIELD VERIFY r ° , FIRE ALARM ADDITION ,, N ,, SCALE: 1/8"=1'-0" WIRING LEGEND A - 18/2 TWISTED, UNSHIELDED, JACKETED FPLP CABLE - ADDRESSABLE LOOP B - 18/2 FPLP CABLE - STROBE CIRCUIT ti (S1) - FROM EXISTING JUNCTION BOX C - 18/2 TWISTED, SHIELDED, JACKETED FPLP CABLE - SPEAKER CIRCUIT #1 (SP1) - FROM EXISTING JUNCTION BOX D - 18/4 FPLP CABLE - REMOTE TEST INTERFACE WIRING • • . / / /// ; Q IN EXISTING J -BOX WITH 5 CABLES EXISTING FIELD FIELD VERIFY VERIFY CABLES CIRCUIT TYPES ADDRESS AND USE ACCORDINGLY SP1 -1 I 1 ' 30cd ABC I —� AD a A,B,C �I9i a 4 �. A 1 ,B,C 4© - R A,B,C . 0 A,B,C . w _Q © D gi22 (A g FIELD VERIFY 1 i i ETING ADDRESS .. - • RUN 102 A,B,C i 0 W 0V N 2 I ll io n U1 © w1. W SPt -2 FIELD VERIFY W o ADDRESS ' m S1 -2 - 0 W m 30cd _ LL .. fit. A ABC ID w+ m 111111111'1 ' IIIIIIIIIIIIIIIIIIIIIIImhui 111111111, W X FIELD VERIFY 3 ADDRESS 3 N J FIRE ALARM DEVICE LEGEND FACP EXISTING FIRE ALARM CONTROL PANEL (SILENT KNIGHT 5820XL) a MANUAL PULL STATION 4e• Alf TO MIDDLE OF DEVICE 0 M (SILENT KNIGHT SD500-PSDA - SINGLE GANG BACKBOX) n O PHOTOELECTRIC SMOKE DETECTOR a 0 0 (SILENT KNIGHT SD505 -APS w /SD505 -6AB BASE - 4' OCTAGONAL BACKBOX) E Q U 10? DUCT SMOKE DETECTOR o 6 (SILENT KNIGHT SD505 -DUCTR w/ SD505 -APS, SD505 -T5) ® DUCT SMOKE DETECTOR REMOTE TEST SWn'CH (SILENT KNIGHT SD505 -DTS -K - SINGLE GANG BACKBOX) R ADDRESSABLE RELAY MODULE g.0 W (SILENT KNIGHT SD500 -ARM - 4' SQ BACKBOX) Gi M )- ® SPEAKER /STROBE Mr ANF TO BOTTOM OF DEVICE C i (SYSTEM SENSOR SP - 4• x 2.188• SQ DEEP BACKBOX) SW EXISTING CEILING MOUNT SPEAKER /STROBE (SYSTEM SENSOR sPSCW) ( JOB NUMBER 2102851 , -AN- E.O.L. RESISTOR i SHEET NUMBER • 1 OF 1 ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: dive- "-eA i AtvD. Ari fl Acit, 1:40404 33153 PERMIT # NEW SERVICE 1 (Overhead ❑ Underground ❑ Underground up Pole ❑ Residential (Main) Service ❑ 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Meters ❑ Commercial (Main) Service ❑ 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps ❑ CT Service amps Conductor Type Size ❑ Multi - Family (Main) Service 0 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Unit Meters ❑ Temporary Pole ❑ amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.) ❑ 100 amps ❑ 150amps ❑ 200amps ❑ amps [ Service amps ADDITIONS, REMODELS, REPAIRS, BUILD -OUTS, ACCESSORY STRUCTURES, ETC. Outlets /Switches: 0- 30amps 31- 100amps 101 -200amps Appliances: 0- 30amps 31- 100amps 101- 200amps A/C Circuits: 0- 60amps 61- 100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS ❑ Swimming Pool ❑ Sign ❑ Smoke Detectors Qty ❑ Transformers KVA ❑ Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts /amps VALUE OF WORK $ 3. / REPAIRS/MISCELLANEOUS ❑ Replace Burnt/Damaged Meter Can ❑ Safety Inspection ❑ Panel Change ❑ OH to UG kOther: ADD /from to ,zrszrvJI OP-4 Am12,1 5757crr i=ofl 7Ht mee -7 ni< evo• -i expaNsia6 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name /ASufato A7 %'r u ItAcH /- -P Phone Number Electrical Company kfe SArel7 pES/Go/s, ZNl Office Phone ("°V) J /7vo Fax (&ids 3.Y: -/z /y Co. Address: 3o3 d' n/ox. 4vj , City TAC //s aw✓lj State fL Zip 34SY License Holder (Print): D0R7L , _ 41/51,45 a Sii a State Certification/Registration # fl- aoom,i'-7,fr 1 1 Notarized Signature of License Holder / # TE=S! -4 31+ l..Efu' P E' Sworn and a Sd su c before lo ;o4s ComtntE DD084707s 3 .. - s • _ ` da y o /' 20 r � v C.n<re,1 /21/2012 's Signature of Notary Pub • u /,, talk /i + i , ' < rtona �aoraMAssn.,tnc = le — — SIN ; EXISTING J —BOX WITH 5 CABLES EXISTING FIELD t FIELD VERIFY VERIFY CABLES CIRCUIT TYPES I ADDRESS AND USE ACCORDINGLY SP1 -1 30cd A B —21A ,-D g M : A,B,C Zei i r 1 A'B'C - > •. 1 BC fifer - R . c , vt ! I i girt FIELD VERIFY l M ETING ADDRESS S • /Iv ROOM � �r \..) 0� A,B,C I � t D1 31N t 1— 9 0 W °v N 2 © LL to FIELD VERIFY G�NG w '3P1-2 ADDRESS W o , es\V{ OF P ` G ° \C > m 10cd ... _ �t�11D1N p A,B,C e i g . , 1i a a C A - fi m 0 111111II117 k. = ; 1111111111111111111111111111111 = u .. I IIIIIIIIIIIIIIIIIIIIIIIII� , 1 . W ADDRRE VERIFY . v I f 3 3 m J FIRE ALARM DEVICE LEGEND FACP EXISTING FIRE ALARM CONTROL PANEL '-__, (SILENT KNIGHT 5820XL) p MANUAL PULL STATION ,B• ArF TO MIDDLE OF DEVICE O M " (SILENT KNIGHT SD500 -PSDA - SINGLE GANG BACKBOX) V i z P HOTOELECTRIC SMOKE DETECTOR z O E (SILENT KNIGHT SD505-APS w /S0505 -8AB BASE - 4' OCTAGONAL BACKBOX) M g p WY DUCT SMOKE DETECTOR ° m c (SILENT KNIGHT SD505 -DUCTR w/ SD505 -MPS, SD505 -T5) i I DUCT SMOKE DETECTOR REMOTE TEST SwiTCH (SILENT KNIGHT SD505 -DTS -K - SINGLE GANG BACKBOX) R ADDRESSABLE RELAY MODULE W (SILENT KNIGHT SD500 -ARM - 4' SO BACKBOX) o 8 SPEAKER /STROBE BG• AFF TO BOTTOM OF DEVICE 30 Z (SYSTEM SENSOR SPSW - 4' x 2.188' SO DEEP BACKBOX) p X EXISTING CEILING MOUNT SPEAKER /STROBE ("'"") ( JOB NUMBER 2102651 , E.O.L. RESISTOR ( NUMBER , 1 of 1 ) 1 EXISTING TO REMAIN EXISTING TO RE6 • a. _ L FIELD VERIFY ADDRESS SP1 -4 FIELD VERIFY RTU -3 D P l' � ,S1 -4 ADDRESS B 1 _ 30cd • j!1 A , � R 17t ©�� ��! • R 1 r Az MEETING R��M Q A ► I + = FIEL�VERSS _ . A re A B,C E A,B,C FIELD VERIFY o A - - ILI111111111111 ADDRESS IIIII 11111111111111111111111 It ' I MIETING IS 'OEM 101 A,B,C FIELD VERIFY ADDRESS IS ffi 0 SP1 -3 S1 -3 A,B,C B A,B,C 30cd r_ • A �I IIIIIIIIIIIIIIIIIIIIII11111111111111111111111 ' '� - FIELD VERIFY � ADDRESS °�� FIRE AL ARM LARM ADDITION SCALE: 1/8 " =1' -0" WIRING LEGEND A - 18/2 TWISTED, UNSHIELDED, JACKETED FPLP CABLE - ADDRESSABLE LOOP B - 18/2 FPLP CABLE - STROBE CIRCUIT #1 (Si) - FROM EXISTING JUNCTION BOX C - 18/2 TWISTED, SHIELDED, JACKETED FPLP CABLE - SPEAKER CIRCUIT 11 (SP1) - FROM EXISTING JUNCTION BOX D - 18/4 FPLP CABLE - REMOTE TEST INTERFACE !IRING