Loading...
Permit 1690 Jordan Street t CITY OF ATLANTIC BEACH TREE REMOVAL APPLICATION All applications must be received by 5,PM on the Monday prior to the scheduled meeting in order to be placed on thea agenda. INCOMPLETE APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE PROCESSED. �� 1�/ 12, 0 ylot-,/ j�l�' /G. _ 2 6 APPLICANT NAME ADDRESS TELEPHONE 2. /ca ADDRESS OR LEGAL DESCRIPTION OF TREE REMOVAL SITE 3. REASON FOR PROPOSED TREE REMOVAL: 4. HAS THIS SITE BEEN TO THE TREE BOARD BEFORE? ❑ YES NO ❑ NOT SURE 5. PROPERTY ZONING: 21 RESIDENTIAL ❑ COMMERCIAL 6. LIST TREES PROPOSED FOR REMOVAL: INTERIOR OR SPECIES DIAMETER * EXTERIOR ZONE** A� �FVIG d�2 * Diameter at Breast Height(D.B.H.) is measured at 4.5 feet above grade. To accurately determine diameter, measure the trunk circumference and divide by 3.1416. Diameter of multi-trunked trees is determined by adding together the diameter of each trunk as measured immediately above the forks. ** See attached diagram for determination of interior and exterior zones. ra 7. SITE PLAN/TREE SURVEY indicating: a) Changes of topographic features such as hills and low areas affecting trees. b) Existing and proposed structures. C) Location of all trees with Diameter at Breast Height (DBH) of six inches or more. d) Tree species and sizes in DBH. e) Trees to be removed should be clearly marked with an"X". f) Trees to be preserved on-site for mitigation must be marked with brackets g) Location, size and species of any proposed new replacement trees marked with a circle "O". h) Location of utilities and easements as applicable. i) Location of trees to be preserved on-site with barricading indicated. 8. ON-SITE REQUIREMENTS: a) All trees identified for removal MUST be marked on-site by RED flagging, paint or tape. b) All trees to be preserved on-site for mitigation MUST be marked with BLUE flagging, paint or tape. C) The front property corners must be marked by stakes or paint indicating the Lot Number or Address. 9. * INCOMPLETE APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE PROCESSED. I HEREBY AGREE TO COMPLY WITH ALL PROVISIONS OF CHAPTER 23, ARTICLE 11, TREE PROTECTION, AND ALL OTHER APPLICABLE CODES AND ORDINANCES OF THE CODE OF ORDINANCES OF ATLANTIC BEACH. x" Applicis Signature Date Owner's Signature Date CITY USE ONLY: Tree Conservation Board Chairperson Date Z//7,000 �f 4 y 1 f � / I a � 12 I N� �9 Yoe/ PrP' BUILDING, PLANNING AND ZONING INSPECTION DEPARTMENT CITY OFATLANTIC BEACH, FLORIDA CER TIFIC4TE OF OCCUPANCY WORKSHEET Date Requested: Al� O Building Contractor�R Building Permit Number: Address : I6 gd)1ZCDA4x) Lecal Descriptio : L0 (/�_ Improvements to the above described property have been completed in accordance with the terms of ,the permit and is certified to be ready for occupancy as L•cwest Floor Elevation: recruired as built BEFORE ISSUING CER777CATF OF OCCUPANCY THE FOLLOWING MUST BE COMPLETE DEPARTMENT DATE NOTIFIED DATE APPROVED BY Fire N Public `forks -- -a(_._� Planning Building MAP SHJVING BOUNDARY SURVEY DF ., THE NORTH 47.50 FEET OF LOT 8, BLOCK 1, ED SMITH SUBDIVISION, AS RECORDED IN PLAT BOOK 26, PAGE 50 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA, TOGETHER WITH THE SOUTH 2.50 FEET OF THE 20 FOOT ALLEY AS PLATTED BY SAID ED SMITH SUBDIVISION, SAID 2.50 FEET OF THE 20 FOOT ALLEY LYING BETWEEN THE NORTHERLY PROJECTION OF THE EAST AND WEST LINES OF SAID LOT 8. fo - - fOiJNO, �I BN//of Z O' ALLEY 6Y OLA T f04V4!¢"/RON/1�E (la ccffi pi�•vuNO'►f CoN�/oE 1V�9 X3(0 � 00 E /00.00 e.9' Q IN 411 .COAIGtETE 13 ONE AIRY Y/Nf[ S/D/NG tz: D!e!vE:ti• of N FIN1fNED FLOO,Q 4 w ELEYsIT/ON!37.44 fi levfCtD ENT�ANtt Q v Farad%'Iron Plop ✓ v y 118 66 45) Jam. 89 36�A0�!4/. X00.X $ This Portion Of Lot 8 Nol Inc/uot-d In This Survey re- Lor 7 ,00 oo. LOT 8 �% y 3 LOT 7 LOT �` o LOT 6 LOT 9 ,o cl N07ES: O BEARINGS ARE BASED ON THE WEST RIGHT-OF-WAY LINE OF ✓ORDAN STREET AS BEING S.0075'00'E 65YI-6.17' NO BUILDING RESTRICTION LINE BY PLAT,BUT THERE MAY BE RESTRICTION LINES OR EASEMENTS THAT AFFECT THIS PROPERTY BY ZONING OR RECORDED/N THE PUBLIC RECORDS OF THIS COUNTY " THAT ARE NOT SHOWN ON THIS SURVEY. THIS PROPERTY LIES/N FLOOD ZONE X"BY FLOOD MAPS 4/17/69, 7 COMMUNITY PANEL NO.120075 0001 D. mom 4a„„, City of Atlanfl' acl7 UU1161lig and PREPARED FOR THE 80E'F1T or: CITY OF ATLANTIC BEACH i' DEPARTMENT OF BUILDING 800 Seminole Road-Atlantic Beach, FL 32233-Tel: 247-5826-Fax: 247-5877 ELECTRICAL PERMIT LOCATION;INFO ,_..Permit Number:Number: 22324 Address: 1690 JORDAN STREET Permit Type: ELECTRICAL ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est. Value: Parcel Number: _ Improv. Cost: ilE3R11 ' IfNw Date Issued: 7/16/2001 _ Name: BEACHES HABITAT Total Fees: 53.00 Address: P. O. BOX 50939 Amount Paid: 53.00 JACKSONVILLE BEACH, FL 32240 Date Paid: 7/16/2001 Phone: (904)241-1222 Work Desc: NEW HVAC r _ CtTRATIF�I 3v".r , �� .. ►PttCATttl�f FEES I OCEAN STATE HEAT &AIR PERMIT 53.00 i +« ROUGH MECHANICAL NOTICE - INSPECTI(*S, M,,' T BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION f.. BUILDING MATERIAL, RUBBISHA DEBRIS FROM THIS WORK MUST NOT BEP` GED IN PUBLIC SPACE, AND MUST BE CLEARED IjP AND HAULED AWAY BY EITHER CONTRACTOR OR OW - - - - - -- "FAILURE TO COMPLY(WITH TkQONSTRUCTION LIEN AN RES4kT IN THE PROPERTY OWNER PAYING G EMENTS" ISSUED ACCORDING TO APPROVED PLANS V'►ffQSH AREARTJFIHI F4RI `AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PILO QV Ii514S OF I ` ( 1 o .• j(j.�f pp i SSS ATLANf C BEACH BUILDING DEPT. atm 7/16/61 61 RK#ipt: W73 I BUILDING AND ZONING NSPECTION DIVISION CITY OF ATLANTIC BEACH ATI-%NTiC STACH.FLORIDA SALTS APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPCRTANT—Applicant to complete ail items in sec"cns I, I1, 111, and IV. LOCATION Street Addrau: 16��� r) Jc' S� , OF lnbrsaollnq Stnee: 30—sn And BUILDING Suh.diritien 11. IDENTIFICATION —To be completed by ail applicants, In Consideration of permit given ter doinq the nark sa datcrib.d in the above statement»s h•raby ages to perform said pork in seeordanee with the attac4d plant .ere .perifications Which are a part hersaf and in accerdants»ith the CSiy of Jecktonvii1e ordinances and standards of good.peectlee bled thoain. Netee of Meehaeleal r� r/ C Cankaeron Coakeater(triol( rt F� Mester V f Name of Signaler•of t>wae Si niiTn+L +' er Acether' gen i•c neer INfC A. T of heating 8• 1Pe IS OTHER CONSTRUCTION BEING DON[ N/' Ry Asia THIS au1L01NG OR SITE? U ) Q baa—Q Lr Q Nuvni ❑ Central U+giiy F IF YES, GIVE NUMBER or tN N ❑ Gg PERMIT n[- ❑ 044W—Specify IV.kQCHANICAL EpUIPM11 T TO It 114TALLM }N��uRE OF WORK (rtenride complete list of tempeaeah on beak of*k fool `l'.1 Residential or ❑ Commercial Heat ❑ Space u tempted "Ittmi Q Rear New Building /6 — two 6two )�k-Ces" Q Existing Building +pecf SyaMn: lAalefie Thickse� Q Replacement of existing system � New Installation(Na syaltNn prwiously Installed) Masisaetn"!.tiff Q Extension or add-on to existing system ❑ R ~kO" ❑ Other—Specify ❑ eoeilaq losers Capacity 146V. C3 ❑ Rte whillj st Nttrnlow of beds - ❑ HaNar (3 httarAff 13 Inviable) T141S S►ACi.f0OR OFFICE USE ONLY Q.Gaadlee pomp• tnw"h'rt (Raa.t•dj ❑,•Tai" -tnasnia.i ft.wana ❑ IJC aRlainws. — !neetber) _ �.. p Wised pew«....." L snail Appsesod by- 13 y Q Wave Q Clbw--specify LIST AL2.EQUIPMENT AIR Cor=nOMNG AND REFR)GMUTIoN 8QUn%w1 CAty •ypsYelAtY Nmaber units Daaaat ]Cd"Numbs• manutacturer (woos) o� --jviIf(UJI AQ2Lj G MATING•FURNACES.BOiIFRSS,Fi[R n AMS �yp�dty A=NeastberVaYtn DeseelptWa ]LedMNtmtber ]Lautstaatvrer (EIV) �! G t TA21E9 S.sial App-wing Bar Yaa1 I111—fual ca b' Tc LWeid 2itame of Na AVt7 area Dlmaeatlsas Caatatoed ]Lataoatsettrter CITY OF ATLANTIC BEACH DEPARTMENT QF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH, FL 32233-TEL: 247-5826-FAX: 247-5877 .I ^ ,. .+vn,.. G:tivr 4Y,..t11 .R0.u...kJ..uNu J ,nW.w.a !.I#"U.r.F�.T..9.., 'CxLvw.•'L�4M.U��« „{+, a:r.,.. Permit Number: 21165 Address: 1690 JORDAN STREET Permit Type: BUILDING ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est. Value: Parcel Number: Improv. Cost: 55,347.00 ` .'OINNER4tNFORMATIOH , . s µ Date Issued: 12/19/2000 Name: BEACHES HABITAT Total Fees: 2,057.14 Address: P. O. BOX 50939 Amount Paid: 2,057 14JACKSONVILLE BEACH, FL 32240 Date Paid: 12/20/2000 Phone: 904)241-1222 Work Desc: CONSTRUCT NEW HOME PER-PLANS HSF 1213 PROPERTY OWNER SEWER IMPACT FEE 1,250.00 WATER METER/TAP 85.00 RADON GAS-H.R.S. 5.77 RADON CAB 5% 0.30 CAPITAL IMPROVE, 325.00 CROSS CONNECTION- 35.00 CONST.SURCHARGE ;` 5.46 SCHARGE/ATL.BCH. ;", 0.61 ----- > WATER IMPACT FEE 350.00 'k FOOTING/SLAB.. R-UP FINAL BUILDING=` CERTIF/OCCUPANCY NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN:,PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER M, "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR:BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICt 1 ARE PART,,OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. Operator: CHERYLE Date: 1/25/81 81 Receipt: 8819645 ATLANTIC BEACH 13UILDING DEPT. Tota] Payment SM7.14 CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH, FL 32233-TEL: 247-5826-FAX: 247-5877 PERMkT(N Permit Number: 21165 Address: 1690 JORDAN STREET Permit Type: BUILDING ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est. Value: Parcel Number: Improv. Cost: 55,347.00 OWNER:CN.F;bRMATiOiY }; > Date Issued: 12/19/2000 Name: BEACHES HABITAT Total Fees: 2,057.14 Address: P. O. BOX 50939 Amount Paid: 2,057.14 JACKSONVILLE BEACH, FL 32240 Date Paid: 12/20/2000 Phone: 904)241-1222 Work Desc: CONSTRUCT NEW HOME PER PLANS -HSF 1213 ------------- ON=FEES ; PROPERTY OWNER SEWER IMPACT FEE 1,250.00 WATER METER/TAP 85.00 RADON GAS-H.R.S. 5.77 RADON CAB 5% 0.30 CAPITAL IMPROVE, 325.00 CROSS CONNECTION 35.00 CONST.SURCHARGE 5.46 SCHARGE/ATL.BCH. 0.61 --.� WATER IMPACT FEE 350.00 dTE FOOTING/SLAB, R-UP FINAL BUILDING CERTIF/OCCUPANCY NOTICE- INSPECTION'S MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. Operator: DOYLE Date: 1/25/91 91 Receipt: 9929645 ATLANTIC BEACH UILDING DEPT. Total Payumt 12857.14 ECITY OF ATLANTIC BEACH )IEPARTMIENT OF BUILDI NI C-3. 800 SEMINOLE ROAD-ATLANTIC BEACH, FL 3/233-TEL: 247-5826-FAX: 24Y-58.17 j: I 1%N1-A, 1 0 rt 1-1 Permit Number: 21188 j Address:� i529 JORDAN STREET Permit Type: FOUNDATION ONLY ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: FRANCIS COVE Est. Value: Parcel Number: Improv. Cost: -0 C �L6r"" ,'': "7.:"",:L "","-','�.�'..";,- WN-RI—WPORMATIORT' Date Issued: 12/21/2000 . Name: BEACHES HABITAT Total Fees: Address: P. O. BOX 50939 Amount Paid: JACKSONVILLE BEACH, FL 32240 Date Paid: Phone: (904)'241-1222 Work Desc: FOUNDATION PERMIT FOR BEACHES HABITAT HOME C PROPERTY OWNER nw,-T el FOOTING/SLAB NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. —S� -- ATLANTIC BEACH B ILDING�DE . CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 Seminole Road -Atlantic Beach, FL 32233- Tet: 247-5826 - Fax: 247-5877 PLUMBING PERMIT PERMIT INFORMATION LOCATIQN INFORMATION Permit Number: 21182 Address: 1690 JORDAN STREET Permit Type: PLUMBING ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est.Value: Parcel Number: Improv. Cost: OWNER JNFORM�4TiON Date Issued: 12/21/2000 Name: BEACHES HABITAT Total Fees: 46.50 Address: P. O. BOX 50939 Amount Paid: 46.50 JACKSONVILLE BEACH, FL 32240 Date Paid: 12/21/2000 Phone: (904)241-1222 Work Desc: INSTALL PLUMBING CONT"046- S r z `P N FEES B& G PLUMBING PERMIT 46.50 t ctions UNDER SLAB PLUMBING SEWERNVATER TOPOUT FINAL NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS ISSUED ACCORDING TO APPROVED PLANS WHIT LAW. 74 PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS O f46. 74 CRgIECK5 1?J21/98 $' 19536 ATLA TIC BEAC BUILDI EPT. M18W32200 CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 Permit Number: 19701 Address: 1690 JORDAN STREET Permit Type: TREE REMOVAL ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est.Value: Parcel Number: Improv. Cost: Date Issued: 3/09/2000BEACHES HABITAT Total Fees: A sr0 BOX 50939 Amount Paid: � � NVIL 2 E BEACH, FL 32240 Date Paid: Work Desc: TREE R VA ..R P°b N ,,,,.,>a PROPERTY OWNER .. x. , A5 ,. A 00-1 T � Y k ' 150 zl 161-1,AM 0", y FINAL - � ., 0 Wi� WON NOTIC' Al, INSPECTIO .UST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERINUBBISH AND R@FROM THIS WORKMU T TBE PLACED IN R JBLIC SPACE, AND MUST BE CLEARED HAULE ,a '�I1/AY"By..E,T , I CQN ,;CSI ISR Old ,WNER "FAILURE TO COMPLY, F THE CONST C I OWNER PAYING TWICE FO�t`' 1J11 ,I C��I ESULT IN THE PROPERTY 1W I ISSUED ACCORDING TO APPROVED PLAkt-'WH, �.O iS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LA CQ� e.—••. ( jt�", AT TIC BEACH bUILDING DEPT. CITY OF ATLANTIC BEACH TREE REMOVAL APPLICATION All applications must be received by 5 PM on the Mondaypriox to the scheduled meeting in order to be placed on the agenda. INCOMPLETE APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE PROCESSED. P':�5 -?C>" ,ra5737 Z'/-/Z Z '— vl-"l 1,:5L -�Tzzz/a APPLICANT NAME ADDRESS TELEPHONE 2. ADDRESS OR LEGAL DESCRIPTION OF TREE REMOVAL SITE r 3. REASON FOR PROPOSED TREE REMOVAU 0 4. HAS THIS SITE BEEN TO THE TREE BOARD BEFORE? ❑ YES 0 NO ❑ NOT SURE 5. PROPERTY ZONING: 2rRESIDENTIAL ❑ COMMERCIAL 6. LIST TREES PROPOSED FOR REMOVAL: INTERIOR OR SPECIES DIAMETER * EXTERIOR ZONE** /,c1L 17�' �x i * Diameter at Breast Height(D.B.H.) is measured at 4.5 feet above grade. To accurately determine diameter, measure the;trunk circumference and divide by 3.1416. Diameter of multi-trunked trees is determined by adding together the diameter of each trunk as measured immediately above the forks. ** See attached diagram for determination of interior and exterior zones. 7. SITE PLAN/TREE SURVEY indicating: a) Changes of topographic features such as hills and low areas affecting trees. b) Existing and proposed structures. c) Location of all trees with Diameter at Breast Height (DBH) of six inches or more. d) Tree species and sizes in DBH. e) Trees to be removed should be clearly marked with an"X". f) Trees to be preserved on-site for mitigation must be marked with brackets g) Location, size and species of any proposed new replacement trees marked with a circle h) Location of utilities and easements as applicable. i) Location of trees to be preserved on-site with barricading indicated. 8. ON-SITE REQUIREMENTS: a) All trees identified for removal MUST be marked on-site by RED flagging, paint or tape. b) All trees to be preserved on-site for mitigation MUST be marked with BLUE flagging,paint or tape. C) The front property comers must be marked by stakes or paint indicating the Lot Number or Address. 9. * INCOMPLETE APPLICATIONS OR INACCURATELY MARKED SITES WILL NOT BE PROCESSED. I HEREBY AGREE TO COMPLY WITH ALL PROVISIONS OF CHAPTER 23, ARTICLE II, TREE PROTECTION,AND ALL OTHER APPLICABLE CODES AND ORDINANCES OF THE CODE OF ORDINANCES OF ATLANTIC BEACH. x" A1i t's,Signature Date ���4j- - z a,e Owner's Signature Date CITY USE ONLY: Tree ConseryBoard Chairperson Date 7 f FOR ANY 4, free Re oval Approved Pp ed i "All treec. to remain mast be barricaded a minima of 5 ft. from the trunk of each > tree. Bari icad s must be installed BEFORE PIXY e site clear ng End remain in place during 7 ( ALL pha s of construction." �II- QV , C�q CITY OF 800 SEMILE ROAD ATLANTIC BEACH,,FLORIDAF32233-5445 TELEPHONE(904) 247-5800 FAX (904)247-5805 SUNCOM 852-5800 DATE -d ! JEA Construction & Maintenance 2325 Emerson Street Jacksonville, FL 32207 Attention: Connie Re: Rough Electrical Inspections Dear Connie: Rough Inspections on the following locations have been completed and approved: PERMIT NO. ADDRESS p Please call me at 904-247-5826 if you have any questions. Sincerely, er / N ATLANTIC BEACH BUILDING DEPARTMENT BUILDING,PLANNING AND ZONING INSPECTION DEPARTMENT CITY OFATLANTIC BEACH, FLORIDA CERTIFICATE OF OCCUPANCY WORKSHEET Date Requested: S-. 7'3`01 Building Contractor: t-6f��A Building Permit Number: aj}u S- Address: Legal Description: Improvements to the above described property have been completed in accordance with the terms of the permit and is certified to be ready for occupancy as Lowest Floor Elevation: required as built BEFORE ISSUING CERTIFICATE OF OCCUPANCY THE FOLLOWING MUST BE COMPLETE DEPARTMENT DATE NOTIFIED DATE APPROVED BY Fire kj�zl --&/A Public Works5�� I Planning Building S7-61 CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address C �1 30 fz-D" Date la -/ ;"'-00 Heated Square Footage 1.213 @ $ per sq ft = $ ,S3 3 ? Z Garag hed @ $ 2�� per sq ft = $ / 000 Carpor /Porch s @ $ per sq ft = $ �1 S - Deck @ $ per sq ft = $ Patio @ $ per sq ft = $ TOTAL VALUATION: S Total Valuation 1st $ ..5(Z/, OJ 3 Y7 /. nom Remaining Value per thousand or portion thereof TOTAL BUILDING FEE $ + 1/2 Filing Fee $ ( ) Fireplaces @ $15 . 00 $ BUILDING PERMIT FEE $ ' WATER IMPACT FEE $ D.0® SEWER IMPACT FEE cro WATER METER/TAP S -Lo- IMPROVEMENT SEWER TAP $ U,�t,5) RADON (HRS) . 0050 $ 7 A � U SECTION H PAVING ( ) $ HYDRAULIC SHARES $ --O CROSS CONNECTION $ O2(3) SURCHARGE .0050 $ 5 Ll4 • G THER $--Z GRAND TOTAL DUE $ 49S— . ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ;SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES: SINGLE FAMILY RESIDENCE HVAC LOAD ANALYSIS for Beaches Habitat P.O. Box 50939 Jacksonville, FL 32240 Oftwo fe RHR�SIDMIAL VAC. HVAC LOADS Prepared By: Jeri Boxx Ocean State Heating&Air Conditioning 1476 Atlantic Boulevard Neptune Beach,Fl- 32266 (904)249-8251 06-29-00 1 RHVAC-Residential 8,Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach,FL 32266-1798 06-29-00 Page 2 Project Summary Project: Single Family Residence Company: Ocean State Heating &Air Conditioning Client: Beaches Habitat Representative: Jeri Boxx Address: P.O. Box 50-439 Address: 1476 Atlantic Boulevard City: Jacksonville,FL 32240 City: Neptune Beach, FL 32266 Phone: 241-1222 Phone: (904) 249-8251 Fax: Fax: (904) 249-8949 Design Data Project Name: Single Family Residence Reference City: Jacksonville, Florida Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 Feet Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factgr: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 27 N/A N/A 72 N/A Summer: 96 78 50% 75 51 Check Figures Total Building Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 Building Loads Total heating required with outside air: 25,232 Btuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible +latent) 1.930 Tons (based on 77%sensible capacity) Notes Calculations are based on 7th edition of RCCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,June 29,2000 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach,FL 32266-1798 06-29-00 Page 3 Total Building Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain ` 3C Window Double Pane Clear Glass 4etal Frame 150 4,894 0 6,728 6,728 10D Door Wood Solid Core 38 787 0 430 430 12C Wall R-11 + 1/2"Gypsum(R-0.5) 934 3,783 0 2,068 2,068 13C Part R-11 + 1/2"Gypsum(R-0.5) 64 130 0 92 92 16G Ceiling R-30 Insulation 1,214 1,802 0 1,802 1,802 22A Slab on Grade No Edge Insulation 149 5,431 0 0 0 Subtotals for structure: 2,549 16,827 0 11,120 11,120 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 2,400 2,400 Lighting: 0 0 0 0 0 Ductwork: 0 1,202 0 1,622 1,622 Infiltration: Winter CFM: 145.6, Summer CFM: 64.7 188 7,203 2,255 1,494 3,749 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,836 Temperature Swing Multiplier: X1.00 Building Load Totals: 25,232 3,175 17,836 21,011 Check Figures Total Building Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 Building Loads Total heating required with outside air: 25,232 Stuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible +latent) 1.930 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,June 29,2000 10BADDRESS146 9�) 3,,dA� � TYPE WORK L(- J mom PROPERTY OWNE,I O C l 1 vl� TELEPHONE CONTRACTOR TELEPHONE !z PERMIT NUMBER "� DATE INSPECTIONS FOOTING SLAB 1 ITE B I LIlVTF.L NAILIIVGASHEATAEVG 77 FRAMINGACO INSo / OLATION Q FINAL BUILDMV CERTIFICATE OF OCCUPANCY �2 _o ELECTRICAL PERDrII3# ',- INSPECTIONS ROUGH "? FINAL M aUMCAL PERMIT# a INSPECTIONS ROUGE Y-19 -Q PLUMBING PERM INSPECTIONS ROUGMUNDER SLAB l2 �22(o TOPOUT 1 v�- WATEMEW.R l(c /0 NOTES: r� - CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 PERMIT INFORMATION 77 LOCA�TIQ JRIYIATION% Permit Number: 19701 Address: 1690 JORDAN STREET Permit Type: TREE REMOVAL ATLANTIC BEACH, FL 32233 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est. Value: Parcel Number: Improv, Cost: s.' C WNEf NIFQt;;tj i 'Ttm=4 1 Date Issued: 3/09/2000 Name: BEACHES HABITAT Total Fees: Address: P. O. BOX 50939 Amount Paid: JACKSONVILLE BEACH, FL 32240 Date Paid: Phone: (904)241-1222 Work Desc: TREE REMOVAL PER PLANS PROPERTY OWNER i FINAL I NOTICE-INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. AT TIC BEACH UILDING DEPT. �RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach,FL 32266-1798 06-29-00 Page 4 System#1 Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 150 4,894 0 6,728 6,728 10D Door Wood Solid Core 38 787 0 430 430 12C Wall R-11 + 1/2"Gypsum(R-0.5) 934 3,783 0 2,068 2,068 13C Part R-11 + 1/2" Gypsum(R-0.5) 64 130 0 92 92 16G Ceiling R-30 Insulation 1,214 1,802 0 1,802 1,802 22A Slab on Grade No Edge Insulation 149 5,431 0 0 0 Subtotals for structure: 2,549 16,827 0 11,120 11,120 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 2,400 2,400 Lighting: 0 0 0 0 0 Ductwork: 0 1,202 0 1,622 1,622 Infiltration:Winter CFM: 145.6, Summer CFM: 64.7 188 7,203 2,255 1,494 3,749 Ventilation:Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,836 Temperature Swing Multiplier: X1.00 System Load Totals: 25,232 3,175 17,836 21,011 Check Figures Supply CFM: 811 CFM per square foot: 0.668 Square feet of room area: 1,214 Square feet per ton: 628.917 System Loads Total heating required with outside air: 25,232 Stuh 25.232 MBH Total sensible gain: 17,836 Btuh 85 % Total latent gain: 3,175 Btuh 15 % Total cooling required with outside air: 21,011 Btuh 1.751 Tons (based on sensible + latent) 1.930 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C,�rs Thursday,June 29,2000 �IRHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ocean State Htg&A/C Single Family Residence Neptune Beach,FL 32266-1798 06-29-00 Page 5 Room Load Summary Reports System#1 Room Load Summary Htg ; Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 1 Bedrms 322 5,283 69 0-0 0 3,637 820 165 1.00 165 165 2&3 2 Bedrm4 322 7,808 101 0-0 0 5,145 950 234 1.00 234 234 Living 3 Bedrml 322 4,517 59 0-0 0 2,963 482 135 1.25 169 135 Bath 4 Kitchen 248 7,624 99 0-0 0 6,091 923 277 1.00 277 277 Dining System 1 1214 25,232 328 17,836 3,175 811 845 811 Totals Main Trunk Size. 12x12 in. System#1 Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tans Split Btuh Btuh Btuh Net Required: 1.751 85%/15% 17,836 3,175 21,011 Recommended: 1.930 77%/23% 17,836 5,328 23,164 System#1 Equipment Data Heating System Cooling System i 4 Thursday,June 29,2000 FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS. , , , PERMIT* BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1214.0 33.05 7223.1 Double,Clear N 1.5 6.0 15.0 19.22 0.94 270.6 Double,Clear W 1.5 6.0 15.0 36.99 0.91 506.7 Double,Clear N 1.5 6.0 30.0 19.22 0.94 541.2 Double,Clear E 1.5 6.0 30.0 40.22 0.91 1101.4 Double,Clear W 1.5 6.0 15.0 36.99 0.91 506.7 Double,Clear S 1.5 2.0 6.0 34.50 0.57 117.0 Double,Clear E 5.5 6.0 30.0 40.22 0.54 649.0 Double,Clear S 1.5 4.0 9.0 34.50 0.74 228.9 As-Built Total: 150.0 3921.6 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 64.0 0.7 44.8 Frame,Wood, Exterior 11.0 934.0 1.70 1587.8 Exterior 934.0 1.70 1587.8 Frame,Wood,Adjacent 11.0 64.0 0.70 44.8 Base Total: 998.0 1632.6 As-Built Total: 998.0 1632.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 6.10 231.8 Exterior 38.0 6.10 231.8 Base Total: 38.0 231.8 As-Built Total: 38.0 231.8 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1213.8 0.60 728.3 Under Attic 30.0 1214.0 0.60 728.4 Base Total: 1213.8 728.3 As-Built Total: 1214.0 728.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 149.0(p) -37.0 -5513.0 Slab-On-Grade Edge Insulation 0.0 149.0(p) -41.20 -6138.8 Raised 0.0 0.00 0.0 Base Total: -5513.0 As-Built Total: -6138.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1214.0 10.21 12394.9 1214.0 10.21 12394.9 EnergyGauge®DCA Form 60OA-97 EnergyGauge@/FIaRES'97 FLRCNA-200 FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT Summer Base Points: 16697.7 Summer As-Built Points: 12770.5 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 12770.5 1.000 0.974 0.341 1.000 4244.0 16697.7 0.3573 5966.1 12770.5 1.00 0.974 0.341 1.000 4244.0 EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®IFlaRES'97 FLRCNA-200 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 1214.0 9.76 2133.8 Double,Clear N 1.5 6.0 15.0 14.30 1.00 215.1 Double,Clear W 1.5 6.0 15.0 10.77 1.02 165.3 Double,Clear N 1.5 6.0 30.0 14.30 1.00 430.1 Double,Clear E 1.5 6.0 30.0 9.09 1.04 282.4 Double, Clear W 1.5 6.0 15.0 10.77 1.02 165.3 Double,Clear S 1.5 2.0 6.0 4.03 2.27 54.8 Double,Clear E 5.5 6.0 30.0 9.09 1.26 344.7 Double,Clear S 1.5 4.0 9.0 4.03 1.35 49.1 As-Built Total: 150.0 1706.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 64.0 3.6 230.4 Frame,Wood, Exterior 11.0 934.0 3.70 3455.8 Exterior 934.0 3.70 3455.8 Frame,Wood,Adjacent 11.0 64.0 3.60 230.4 Base Total: 998.0 3686.2 As-Built Total: 998.0 3686.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 38.0 12.30 467.4 Exterior 38.0 12.30 467.4 Base Total: 38.0 467.4 As-Built Total: 38.0 467.4 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1213.8 1.20 1456.6 Under Attic 30.0 1214.0 1.20 1456.8 Base Total: 1213.8 1456.6 As-Built Total: 1214.0 1456.8 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 149.0(p) 8.9 1326.1 Slab-On-Grade Edge Insulation 0.0 149.0(p) 18.80 2801.2 Raised 0.0 0.00 0.0 Base Total: 1326.1 As-Built Total: 2801.2 INFILTRATION Area X BWPM = Points Area X WPM = Points 1214.0 -0.59 -716.3 1214.0 -0.59 -716,3 EnergyGauge®DCA Form 60OA-97 EnergyGauge®lFlaRES'97 FLRCNA-200 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: s BASE AS-BUILT Winter Base Points: 8353.8 Winter As-Built Points: 9402.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 9402.1 1.000 0.990 0.487 1.000 4532.2 8353.8 0.5340 4460.9 9402.1 1.00 0.990 0.487 1.000 4532.2 EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: s BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2746.00 10984.0 50.0 0.92 4 1.00 2526.61 1.00 10506.4 As-Built Total: 10506.4 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 5966.1 4460.9 10984.0 21411.0 4244.0 4532.2 10506.4 19282.6 F:PASS y�yo4 sTAT�oA�+ rl c01)WE EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details [ADDRESS: , , , PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows& Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area; .5 cfm/s .ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between wails and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit breaker electric or cutoff as must be provided.External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min. R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-11. EnergyGa uge rm DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score,the more efficient the home. 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap: 100.0 kBtu/hr 3. Number of units,if multi-family I - SEER: 10.00 4. Number of Bedrooms 4 _ b.N/A 5. Is this a worst case? No _ 6. Conditioned floor area(ft) 1214 ft2 c. N/A 7. Glass area&type _ a. Clear-single pane 0.0 ft2 _ 13. Heating systems b. Clear-double pane 150.0 ft2 - a. Electric Heat Pump Cap: 100.0 kBtu/hr _ c. Tint/other SC/SHGC-single pane 0.0 ft2 _ HSPF:7.00 d.Tintiother SC/SHGC-double pane 0.0 ft2 b.N/A 8. Floor types _ a. Slab-On-Grade Edge Insulation R=0.0,149.0(p)ft _ c. N/A b.N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap:50.0 gallons _ a. Frame,Wood,Exterior R=11.0,934.0 ft2 _ EF:0.92 _ b. Frame,Wood,Adjacent R=11.0,64.0 ft2 _ b. N/A _ c.N/A _ d.N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,1214.0 ft2 _ 15. HVAC credits b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Interior Sup.R=6.0,25.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) "'t%E sT9T1 in this home before final inspection. Otherwise,anew EPL Display Card will be completed ti - based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: �'coD Vv� 4�5 *NOTE: The home's estimated energy performance score is only available through the FLAIRES computer program. This is not a Building Energy Rating.Ifyour score is 80 or greater(or 86 for a USEPA/DOEEnerg6tarTMdesignation), your home may qualify for energy efficiency mortgage(EEAIP incentives if you obtain a Florida Energy Gaugl-Rating. Contact the Energy Gauge Hotline at 407/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters.For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge®(Version:FLRCNA-200) RECEIVED PROPERTY DESCRIPTION Lot # 0 , Block # Section # uLv 7 2000 Subdivision: City of Atlantic Beach Street Name /� / DESCRIPTION �uitand Zoning or Address: IVI 7 A 9 x.10 J0,0/V sG1W,,F7— (If in a FLOOD HAZARD Flood Zone: area complete page 3) Brief Description_.S(/✓61��f�yJ/Ly,yOM,E Class of Work: (New/ Remodel/Addition: NeW ZONING INFORMATION Type of Construction: 0001�1) `t'Z#A96 Zoning Proposed /' District: Use: leI6(E/�"�►'wo Estimated Value $ a Exceptions or Variances Materials: Ndop', Y/NyL- Granted; 1110A46 !— �I Solid or Filled (� Ground: S'C�LI(� Roof l�/ 6 Gi(jsS. /9(IN4W'T Method of Heating: M6W PUP OWNER INFORMATION Property Owner: Phone:Ci?V J 1 L2-2--- Mailing Address ,g"p .5b V1 Zip: `�2 2-yo CONTRACTOR INFORMATION Contractor: �ESWV TR% Phone: Mailing Address: t3pk 22 ' Zip: 2SGa Expiration STATE LICENSE NO: Date: I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL RULES, REGULATIONS, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE VE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATAVE B EN O HAL BE PROVIDED AS REQUIRED. Owner SignatureFX�TC DATE a44#& Contractor Signature ) J —nje' DATE L O0 SWO TO AND SUBSCRIBED BEFORE ME BY 6Ad THIS _ DAY OF ry•,� Carol A Marcello �/� . NOTARY PUBLIC Expires June 08,2004 FLOODPLAIN DEVELOPMENT INFORMATION Location:: /G 90 -�O,2�64Al ! d 7-c..4A/ Type of Development: S�NGGE �R.►-,jL y Flood Zone: rC Required Lowest Floor Elevation: If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. Date, y Applicant's Signature ;;3r9CW:S' //�1-3,17;P7— Department Use: Required Lowest Floor Elevation As Built Lowest Floor Elevation Survey Filed with Building Department Building Department Representative MAP SHOWING BOUNDARY SURVEY DF, THE NORTH 47.50 FEET OF LOT 8, BLOCK 1, ED SMITH SUBDIVISION, AS RECORDED IN PLAT BOOK 26, PAGE 50 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. R lFV E DEC 7 2000 _ City of Atlantic Beach Building and Zoning ZO' A L L E Y fyrrnd!�t'/ran Pix �e yriG45j�� X00. moo' W 8 � pie I`asj 1'°r S. 88 036'00"it/. /00.00' W This Rbrtion 4V Lof 8 Nof/x/artrd/n Thrf SurKy M -� LOT 7 'pro y > LOT 7 LOT 6 /00oo' LOT 8 „ LOT 9 LOT 6 Zt 4- I Th'N instrume was pre ared by ZA %O 77450 P.O. Box 50939 Raee., 21aga CO Jacksonville Beach, Florida 32240 Filed & Recorded 12/04/2000 11:06. AM W _ HENRY Y COOK CLERK CIRCUIT COURT y MIN. RETURN NOTICE OF COMMENCEMENT Duval. COUNTY PHONE; �41— ��a COPYTFEEND $ 1.40 CL RECORDING I 5.00 STATE OF FLORIDA Permit No.: In COUNTY OF DUVAL Tax Folio No.: .q a0 M The undersigned hereby gives notice that improvements will be made to certain real property,and 0 in accordance with section 713,Florida Statutes, the following information is provided in this Notice of p Commencement. A4 1. Description of property:(legal description of property and street address if available) .S T /-'4JGC.' ►'1 rue cse4^1. 12t� 2. General description of improvements: To build a single family residence 3. Owner Information: a. Name and Address: Habitat For Humanity Of The Jacksonville Beaches, Inc. P.O. Box 50939, Jacksonville Beach, FL 32240 b. Owner's interest in the site of the improvements: 100% C. Name and Address of fee simple title holder(if other than owner) : N/A 4. Contractor: a. Name and Address: As b. Phone Number: A 4-1 _ / Z Z i-- c. Fax Number:(optional, if service by fax is acceptable) 5. Surety on any payment bond: NONE 6. Name of any lender making a loan for the construction of the improvements: N/A CITY OF ATLANTIC BEACH, FLORIDA l7 _ Approved by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:�� 19 L IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM" SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN'ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ( A! /Ej �" ELECTRICAL FIRM S�;yy ���� J MAST ELECT JAN SIGNATURE pJOURNEYMAN NAME 1 eLw-s ' �`��'� ADDRESS: Z6 �1.�,T ®lam-p J RFD-SOX- BLDG. FDBOXBLDG.SIZE /&e)52 / ZA7- - BETWEEN: "5 AD ` eO 76K r✓i s/1 stJ RES.s?Q APT.( 1 COMM.( ) PUBLIC( ) INDUS.( i NEW,04 OLD( 1 REW.( ► ADDITION( ) TRAILER ( 1 TEMP.( I SIGNS ( 1 SO.FT. SERVICE: NEW INCREASE( ) /` REPAIR ( 1 FEE CONDUCTOR SIZE r AMPS/,5e COPPER I ALUM. SWITCH OR BREAKER AMPS I PH I W VOLT RACEWAY EXIST.SERV.SIZE AMPS PH I W VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0-30 AMPS. ]1•f 00 AMPS. SWITCWES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVSA APPLIANCES BELL TRANSF. AIR H.P.RATING H.P.RATING ' CONDITIONING COMP-MOTOR OTHER MOTORS AMPS CELL HEAT: KW-HEAT 04 oval MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS TRANSFORMERS: UNDER 600 V. OVER 600 V. NO. KVA NO. KVA NO.NEON TRANSF. NO. VA. MA. MOTOR SIZE SWITCH FLASHER EACH SIGN -- FORWARDED s TOTAL FEES F ' CITY OF ATLANTIC BEACH a . APPLICATION FOR PLUMBTNG ;PERMTT t 30B LOCATION: 1410 'TQ/Z p o►.1 S -rR E.,E T- a Etc II ESA-Q OWNER OF PROPERTY : � '►'�T' TELEPHONE NO . PLUMBING CONTRACTOR {3CV nn,Q,,jb c o , .r I• CONTRACTOR' S ADDRESS : (39R -7 464CN QLv� STATE LICENSE NUMBER: G C a Z 2 S `13 TELEPHONE : zz 3 3585 HOW MANY OF THE FOLLOWING FIXTURES INSTALLED ( SINKS SHOWERS Z LAVATORY I WATER HEATERS Z BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS WASHING MACHINE FLOOR DRAINS SHOWER PANS SEWER WATER REPIPE OTHER TOTAL FIXTURES :-- _ x $3 . 50 a $ 15 . 00 `?��• S ° MINIMUM PERMIT FEE - $25 . 00 SIGNATURE OF OWNER: SIGNATURE OF CONTRACTOR: ----------------------------------------------------------------- INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH1` THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE .: CALL A DAY AHEAD TO SCHEDULE INSPECTIONS - (904 ) 247-5826 SEWER CONNECTIONS MUST BE CALLED INTO PUBLIC WORKS FOR -INSPECTION PRIOR TO COVERING UP - (904 ) 247-5834 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Beaches Habitat Spec 1214 Builder: Beaches Habitat Address: 16FU•. � , Permitting Office;e rz-4A177C ei fk if City, State: F� �-� � F�3Zz.37 Permit Number: x116.11 Owner. & :At: A/317-fit`, Jurisdiction Number: ( Climate Zone: North j1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family a. Central Unit Cap: 100.0 kBtu/hr _ 3. Number of units,if multi-family 1 _ SEER 10.00 _ j 4. Number of Bedrooms 4 _ b.NIA 15. Is this a worst case? No 6. Conditioned floor area(W) 1214 W c.N/A _ 7. Glass area&type j a. Clear-single pane 0.0 ft 13. Heating systems b.Clear-double pane 150.0 W a. Electric Heat Pump Cap: 100.0 kBtulhr _ c. Tint/other SC/SHGC-single pane 0.0 f 2 HSPR 7.00 d.Tintlother SC/SHGC-double pane 0.0 ft= b.N/A _ i8. Floor types _ a. Slab-On-Grade Edge Insulation R=0.0,149.0(p)ft c.N/A b.N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap:50.0 gallons _ a. Frame,Wood,Exterior R=11.0,934.0 fP _ EF:0.92 _ b.Frame,Wood,Adjacent R=11.0,64.0 ft_ b.N/A c.N/A _ d.N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a.Under Attic R-30.0,1214.0 fP _ 15. HVAC credits _ b.N/A (CF-Ceiling fan,CV-Cross ventilation, c.N/A HF-Whole house fan, 11. Ducts PT-Programmable Thermostat a. Sup:Une. Ret:Unc. AH:Interior Sup.R-6.0,25.0 ft RB-Attic radiant barrier, b.N/A M&C-Multizone cooling, M&H-Multizone heating) Glass/Floor Area: 0.12 Total as-built points: 19283.00 PASS Total base points: 21411.00 I hereby certify that the plans and specifications covered Review of the plans and by this calculation are in compliance with the Florida specifications covered by this +.o�� So Energy Code. calculation indicates compliance € A ! PREPARED BY: Ocean State HVAC with the Florida Energy Code. DATE' 6a- -tom Before construction is completed a this building will be inspected for 1 hereby certify that this bui 'ng,as de ned,is in compliance with Section 553.908 compliance with the Florid ergy C Florida Statutes. °D OWNER/AGENT: BUILDING OFFICIAL: . DATE: DATE' ,C_ a. EnergyGauge®(Version: FLRCNA-200)