Loading...
Permit Wind/door 548 Viking Ln 2010 r ,,„. 'lr ' „` CITY OF ATLANTIC BEACH . 4 �> ) 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 ” ` INSPECTION PHONE LINE 247 -5826 �� Application Number 10- 00001486 Date 12/22/10 Property Address 548 VIKINGS LN Application type description WINDOW AND /OR DOOR Property Zoning TO BE UPDATED Application valuation . . . 4668 Application desc window replacement Owner Contractor GESSEL, CHAD WINDOW WORLD OF JACKSONVILLE 8110 CYPRESS PLAZA DR #405 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256 (904) 249 -6111 (904) 443 -7001 Permit WINDOW AND /OR DOOR PERMIT Additional desc . Permit Fee . . . 75.00 Plan Check Fee . . 37.50 Issue Date . . . Valuation . . . . 4668 Expiration Date . 6/20/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE DCA SURCHARGE 2.00 STATE DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 75.00 75.00 .00 .00 Plan Check Total 37.50 37.50 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 116.50 116.50 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION . CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247 -5826 Fax (904) 247 -5845 Job Address: F) V l \ 5 Lan-e..- J� , FL 3 Permit Number: /0 - /'f Legal Description 3S -(p ( 11- a1 ,CUs to k a• Parcel # 1')0 h3 - Oaf 2. F loor A re f of Sq. Pt. Sq.Ft Valuation of Work $ Ug Proposed Work heated /cooled 1 a5 (4 non - heated /cooled /4 Class of Work (circle one): New Addition Alteration Repair Move Demolition pool /spa window /door Use of existing /proposed structure(s) (circle one): Commercial [Residential If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N /A Florida Product Approval # g 1 3c . I i- V1,34). 41 For multiple products use product approval Describe in detail the type of work to be performed: \/ Irmo!~) re e1ac.e v _!/ 4 Property Owner Information: Name: 1 � . 5 Address: 5 (/ </ 13 ifek" ,$ , City , A_ 4 6 Statea_Zip 3ZZ 3 Phone 2�t( 22.c E -Mail or Fax # (Optional) Contractor Information: Company Name: World 1,4 Snc gnnva fsa,, Qualifying Agent: G ✓ e 9 a� 2- R-1-e. Address:81 0 _ II ' 2 . . e. .. _ +._ , e ,...V 1 • J State F L Zip ,?, aZ_(p Office Phone ., - 001 Jo., t � < ; _'l_:X - ,r p /-fc/3- 7'7 '7b' _ State Certification /Registration # C . G I .: .' - • ' kii � 1 iii • 1 1 ' {' R /� CE Architect Name &Phone # VII 1 a or = Engineer's Name & Phone # I SEE PE' . yw iitibor Fee Simple Title Holder Name and Address I REQUIREMENTS AND a Of Iii • . 1 t a: II 1 . Bonding Company Name and Address (- gill n 1 1, ` Mortgage Lender Name and Address [ p` „ DATE ;�.�.1�,(l� =Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certi that no work or installation has commenced riot rill issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction, This permit becomes nail and void if work is not commenced within six (6) months, or if construction or work is sus ended or abandoned for a period of six 6) months at any !line odic, work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters Tanks and Air Conditioners, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. l hereby certify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing 1111. type of work will be complied with whether s eci ied herein or not. The granting of a permit does not presume to give authority to violate or cancel 112, provisions of any other federal, st te, r local w r gulating construction or the performance of construction. Signature of Owner Signature of Contractor _ , Ilk., if __ _ Print Name ro „ � C.4 4 s5C( Print Name � # Sworn to and subscribed before mg Sworn to and subscribed before me this /G Day of pe.CCA, e , 20 /0 this 2-( Day of 73,2_ r , 20 /ca l , . •a.r Notary Public �p�" """ Notary 'ublic fir: " ;.;Y _ CARLA JEAN PROBST " �. ARIA JEAN PROBST ! MY COMMISSION # DD 955269 t _,� r MV u0NI I O A� Q X5269 ; w 4 ' 0 FIRES: January 25, 2014 . • J anua 25, L tat aed . ,ru Notary Publ Underwriters ,j '4 , 8r.,tz o unaed Thru Notary Public Underwriters Doc # 2010292495 OR BK 15463 Page 1324, NOTICE OF COMMENCEMENT Number Rages: 1 Recorded 12/21 2010 at 0220 PM. JIM FULLER CLERK CIRCUIT COURT DUVAL 86 COUNTY Permit No. © '-1 `y v RECORDING $10.00 Tax Folio No. 11 0"103 - oa a. THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property (legal description): 99 5easeral Co- 5 elk a 9�-to� t`l -2lS- a) Street (job) Address: 5' Vi kinoo L t ASrAperlic, eaac -V F[ i rl 3x233 2.General description of improvements: Wfn air. vv r one ne wl 3.Owner Information a) Name and address: CM—) XT.5C ( 5 8 \ ► )c. s c b) Name and address of fee simple titleholder (if other than owner) V al ► gy p " '�� c) Interest in property S Jr' tj � � 4.Contractor Information (J J a) Name and address: Wt rap .,v o-dd OC In ot�;►�ls- `� ►�� b) Telephone No.: Lit-1.3- 7 0 ' ' P • Sk- '. A2.5 �0 5.Suret Information Fax No. (Opt.) • 413- ? _ -�-7 S `0 a) Name and address: b) Amount of Bond: c) Telephone No.: Fax No. (Opt.) blender a) Name and address: Phone 7. Identity of person within the State of Florida designated by owner upon whom noti es or other documents may be served: a) Name and address: b) Telephone No.: Fax No. (Opt.) 8.In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes: a) Name and address: b) Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEME T. . STATE OF FLORIDA COUNTY OF PINELLA 10. �^ CARLAJEAN PROBST Signature of Owner or Owner's r/ er's Authorize 0 ficer /Director /Parts Manager 3►r "` :r MY COMMISSION #DD955269 C4�-ll4 ��// r j [� y) EXPIRES: ES: January 25, 2014 Ak tii∎it Fton;;ad Thru Notary Public Underwriters Print Name �y The foregoing instrument was acknowledged before me this 2.1 day of cam , 20 l o , by v�i .... as / t4".a (type of authority, e.g. officer, trustee, attorney in fact) for (name of y ( part on behalf of whom instrument was executed). Personally Known OR Produced Identification v Notary Signature Type of Identification Produced Name (print) � � TC�-- A be OR Verification pursuant to Section 92.525, Florida Statutes. Under penalties of perjury, I declare that 1 have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. I ORMS/NOC,rvsd2010 Signature of Natural Person Signing (in line N 10.) Above House Map For: Chad Gessel Window World of Jacksonville, Inc 548 Vikings Lane 8110 Cypress Plaza Dr. Ste 405 Atlantic Beach, Florida 32233 Jacksonville, FL 32256 Contractor: Gregory Fite License No.: CBC1250321 5 V — 1 g _q NOT TO SCALE I I I Window Size Manufacturer Window Type & DP Rating 1) 35 15/16 x 61 5/8 Alside Inc/ Div of AMI 201 DP 50 2) 35 15/16 x 61 5/8 Alside Inc/ Div of AMI 201 DP 50 3) 34 7/8 x 51 1/8 Alside Inc/ Div of AMI 201 DP 50 4) 35 x 51 1/8 Alside Inc/ Div of AMI 201 DP 50 5) 51 x 49 1/4 Alside Inc/ Div of AMI 501 DP 40 6) 24 3/8 x 36 7/8 Alside Inc/ Div of AMI 201 DP 50 7) 51 1/8 x 49 3/8 Alside Inc/ Div of AMI 501 DP 40 8) 35 1/4 x 36 1/2 Alside Inc/ Div of AMI 201 DP 50 9) 34 7/8 x 49 1/4 Alside Inc/ Div of AMI 201 DP 50 10) 37 1/4 x 49 1/2 Alside Inc/ Div of AMI 201 DP 50 Florida Building Code Online Page 1 of 3 BCIS Home Log In User Registration : Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search ret Product Approval fit ittr va. USER: Public User ' M441 ommunity Affairs Product Approval Menu > Product or Application Search > Application List > Application Detail Q FL # a rt FL8134 -R6 Application Type Revision � Code Version 2007 , 5..,emu a Application Status Approved '' Comments 11 Archived Product Manufacturer Alside Window Company Address /Phone /Email 3773 State Road Cuyahoga Falls, OH 44223 (330) 922-2108 rickw @rwbldgconsultants.com Authorized Signature Marsh Fernbaugh rickw @rwbidgconsultants.com Technical Representative Marsh Fernbaugh Address /Phone /Email 3773 State Road Cuyahoga Falls, OH 44281 mfernbaugh @alside.com Quality Assurance Representative Address /Phone /Email Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Lyndon F. Schmidt, P.E. developed the Evaluation Report Florida License PE -43409 Quality Assurance Entity Architectural Testing, Inc. Quality Assurance Contract Expiration Date 12/31/2011 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL8134 R6 COI Certificate of Indeoendence.pdf Referenced Standard and Year (of Standard) Standard Year 101 /I.S.2 1997 AAMA/ W DMA /CSA101 /I. S.2/A440 2005 Equivalence of Product Standards Certified By Sections from the Code http: / /www.floridabuilding.org /pr /pr_ app_ dtl. aspx ?param= wGEVXQwtDqu l j dteSXaTw... 12/21/2010 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 07/15/2010 Date Validated 09/13/2010 Date Pending FBC Approval 09/16/2010 Date Approved 10/13/2010 Date Revised 12/15/2010 Summary of Products • FL # r or Name Description 8134.1 InErdel 0201 Extruded Vinyl Double Hung Window "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports ". Other: See INST 8134.1 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.1.pdf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. 8134.2 l b. Model 0301 Extruded Vinyl Double Hung Window with Nail Fin - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.2 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.2.odf any additional use limitations, Installation instructions Created by Independent Third Party: Yes and product particulars. 8134.3 jc. Model 0401 Extruded Vinyl Double Hung Window - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes • Design Pressure: N/A Evaluation Reports Other: See INST 8134.3 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.3.pdf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. ,,„1.10� 8134.4 tE 0501 A OMMIIIII Extruded Vinyl Double Hung Window - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.4.pdf ' Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.4 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.4.pdf any additional use limitations, installation Instructions Created by Independent Third Party: Yes and product •articuiars. 8134.5 1e. Model 0501 HP Extruded Vinyl Double Hung Window - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.5.pdf ':. Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.5 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.5.pdf any additional use limitations, installation instructions Created by Independent Third Party: Yes and • roduct particulars. • 8134.6 If. Model 0601 Extruded Vinyl Double Hun• Window - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.6 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.6.odf I any additional use limitations, Installation Instructions Created by Independent Third Party: Yes I and •roduct particulars. http:// www. floridabuilding .org /pr /pr_app_dtl.aspx ?param= wGEVXQwtDqu 1 j dteSXaTw... 12/21/2010 Florida Building Code Online Page 3 of 3 j 8134.7 N. Model 8001 Extruded Vinyl Double Hung Window - "Non- Impact" Limits of Use Installation Instructions i Approved for use in HVHZ: No FL8134 R6 II INST 8134.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.7 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.7.odf any additional use limitations, Installation instructions Created by Independent Third Party: Yes and product particulars. 18134.8 h. Model 9001 Extruded Vinyl Double Hung Window - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.8.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 pP y' y Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.8 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.8.odf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. 8134.9 i. Model "i' 201 Extruded Vinyl "Tilt" Double Hung Window - "Non - Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.9 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.9.odf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. 8134.10 j. Model V101 Extruded Vinyl Double Hung Window with Nail Fin - "Non- Impact" Limits of Use Installation Instructions f Approved for use in HVHZ: No FL8134 R6 II INST 8134.10.l2df ( Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes • Design Pressure: N/A Evaluation Reports Other: See INST 8134.10 for Design Pressure Ratings, FL8134 R6 AE EVAL•8134.10.odf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. 8134.11 [k. Model V121 Extruded Vinyl Twin Double Hung Window with Integral Mullion and Nail Fin - "Non- Impact" Limits of Use Installation Instructions Approved for use in HVHZ: No FL8134 R6 II INST 8134.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8134.11 for Design Pressure Ratings, FL8134 R6 AE EVAL 8134.11.Ddf any additional use limitations, installation instructions Created by Independent Third Party: Yes and product particulars. Back I Next 1 Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399 -2100 (850) 487 -1824, Fax (850) 414 -8436 © 2000 -2010 The State of Florida. All rights reserved. Privacy Statement I Coovriaht Statement I Accessibility Statement I plus -in Software I Customer Service Survey I Contact Us Product Approval Accepts: SCCUrit 111 MR'S' gV"49" r ti SAFE ii r'rrrt http: / /www. floridabuilding. org /pr /pr _app_dtl.aspx ?param= wGEVXQwtDqu 1 jdteSXaTw... 12/21/2010 RLIA- GmYrfc \pmja+FnlMn \Drnj 17111- 11M1rf 1]71‘n 9WRf nraueinrocV1- R1gLIVI A 114L 1 AaD j1.9f.7S1 5A A W IJ V ul> wn1— M V GO r O (p CD O O N? 1.6.'n z N-1 m W < 2 '� - O V c � O 7 c-8. c N N A c o =n 0 m 2.2,_ 3 w a q9. m m'o VP. ;5- 7 0 7 - Z O • §ia°g = 7 D. n o o a no v D ti O S 0 7 a3 C 9. moo 3n ° o m° om c 3 g. 3 3 "3 R 2 Q 7 g- -9 5: O CI? 2 w �7 M o c o (1 a ■ O m a3 o m 8 . oa a °- z = C O D 8 o- m fi n 8 g o a s x a Z r- , �� c v v rr 3 / m � O r•- 3 Q o o �• . a s c 3 n V J v O = E N _ T •a 1 $ � y-- Z Z4 w v ; a gg 0 3 j r 3 o Y2. < g. Z '� .. • � a o? Qm 5 - =. v -4 r" 0 �� p T 0 B -. o = * r� = 3 0 � s , , CD Q o a I El a 0 co CZ 5 - a �D = a IJ 6 0 O 4 4 R �{ i< 0. K k K x Zit A O O V . . g �i 78.00" MAX. O. A. FRAME HEIGHT a a 01 0 > ti 0 _ x x x x x 1" .. _._. ... ... .` f ti. a• P P P -! Y 1 Y it �. d d Pa H y y .51 o r Q � • x { x , � W x O > _ H H N2 p... b 47 0 0 0 0 0 \, P‘ o o \ 1 Ln A N U W " P‘ \ vt x o o 0 0 0 , R I 01 1 e 01 o , r b '' > M o 0 0 0 0 � _ .............. 4 Q PRODUCT: oocnt. Procne By: 25 � BUILDING CONSULTANTS. INC. P DOUBLE HUNG WINDOW W P.o. Bo. 230 V9lriao FL 33595 I - g, Z N Phone No.: 813.559.9197 g ' r- –( to 2 3 10//10 ANCHOR CORRECTION JK PART OR ASSEMBLY: FloAda Board m Professional E I : 4 -L,1 c n 1 8)20J09 ANCHOR CLARIFICATION RW TYPICAL ELEVATION, DESIGN Certificate / oe Authorization No. 9613 t7 -' oo NO, DATE BY PRESSURES & GENERAL NOTES 9 6.4340 REVISIONS Lmeon F. Sohmlet P.E. No. 43409 ® 2009 R.W. BUILOINO CONSULTANTO INC. US . DrnienzAplart FnlAers\pl 17111_iinfllpf 17 1 DWRr I rewingcVI .R1a4\Ft .A 114A 1 Aug 7 1 40 0 1 110 01 I l 1 411) e 1 0 410 0 s_ 4D �` N a p A 5. z - n 4 yy 4D j D O y 7 Z Z Z fm F . . O O N 3 g2- Poi R X 3 '0 ,I a A s o _ _.g cl n �11 o .< 9° CD ^ e. � IN • E IR 110.110r 41) CI F - El I ...pia o P. — —• z O NN � ii __ 0 5.� o' 6 N n^n1 ° C) O �N11• a zN O m : 1, :?...,„,9, \-] , 7.4. S A p> e p C1 i....j. j , A 0 all Tgdgk il a 0 Voir lia•L - na • 7 P. il i 41 i1M ,.., �0 m ' • PVI F. po' N h I PRODUCT: Damon-wits Prepared By P- �p BUILOING CONSULTANTS. INC. I N b N DOUBLE HUNG WINDOW r/� W P.O. Bo. 230 Vain.. FL. 33895 CO C Z Phone No.: 813.559.9197 R L;, .. r - y Ln 2 03/18/10 ANCHOR CORRECTION JK PART OR ASSEMBLY: Florida Board of Professional Engineer, ;` 0 In O 1 8/20/09 ANCHOR CLARIFICATION RW Certificate Of Authorization No. 9813 of NOI DATE BY HORIZONTAL CROSS SECTIONS if REVISIONS & GLAZING DETAIL �� 9./2-47 Lyndon F. Schmidt, P.E. No. 43409 09 © 2009 R.W. BUILDING CON.ULTANT. INC. R: A - or„1.rtelOmy,rr Fnld>rsIprn117n1- 1iflnlrf 1771 \11 ownr nrowingelF1- 412A1C1 91244 1 nue2 11 °? or ° ° ° W Al T 0 70 ° ° a ■rrn va MAX. n ' a ° + SHIM SPACE y f o m .: 1— Q o air Z o m Q NI a , , Z r.„. 0 I D ° e p O O °� CIO © 9 o a 0 CI w w ° I T °o O 0 70 — Ti o s Q Z O ° • H ., O w l� ■E Z ° _� 0 0 0 0 o 1/4 " MAX. $ SHIM SPACE O O © SHIM PACE —` a 4 — A ft 77 GILL' d ` ° : n 12) tae 0 ci) el ,ii:1-11.' °11-11 111111 '' 4 '1* r. . r _r_ , ! k 1 I 0 0 0 0 0 0 p / 4 0 . ' 4, 8 0 O 1 -1/4" MIN. EMS. r. PRODUCT: Document. Pr.por.d By: BUILDING CONSULTANTS, INC. WI1i I * " Z N DOUBLE HUNG WINDOW P.O. Box 230 Vain... Fl 33595 00 , Phon. No.: 013.059,9197 $ W - —1 to 2 0,3/18/10 ANCHOR CORRECTION JK PART OR ASSEMBLY: Florida Board of Prof...lona! Engineer. Tx h 5 F y a 1 8/20/09 ANCHOR CLARIFICATION RW Certificate Of Authorization No. 9813 03 N0, DATE BY VERTICAL CROSS SECTIONS L7--c....- �. ,, /o REVISIONS Lyndon F. Schmidt, P.E. No. 43409 02009 R.W. BU,LOINS CONSULTANTS INC. R., A . D..liMr iy♦• FNAa.r\Dmi »n1.1 a1np? 1»n'n DWPr nr.mingr`FI _41a4lFI .R11441 Awl 41 4 N- OK N o f c1 0 ="(0) -0 „ X El m nn 2 g 3 78E ZZ Co c . g a a -. . • x v :0 e. � ..• �a 7 n Z :. C .-ii H z 0 0 x 8 0 ' n S ,?, h. : .s i • °.. rn 3 3 o >e v : g,< g + rn a . moa 4” --.-1 CD a m c 4" —.•-i •� a3om' re) •a 3 ' c 3 e z' 3 3 0 > � .. N o 5 • o � -0 cn Pzi m C y CS r n . ; 0 3 m '. m C)-< :.' • r ij ' - 3 a . �CC� W a 3 0 . >x Er go •. 6 O N 7 w 3 o a b x 1 1All Q a' 0 wry g . I o p- 0 Q 0 I 3" 6" --∎1 I a • 7 ] 7C A \ I / o y rr10 •• ...I 1 / rri z 2 ''1 E • •*. •••• •,. . ... ..- e' x..• A 0 T T 1 �� 111 .. II n f 611 7 6.. 3" 5 0 N A PRODUCT: Documents Prepared Or T 7 BUIIDINO CONSULTAN INC. T p � -' DOUBLE HUNG WINDOW �P.o. Bo 230 Voh10 TS• F L 33595 I4` Co Z N Phone No.: 813.659.9197 $ w ' y • u 2 03/18/10 ANCHOR CORRECTION JK PART OR ASSEMBLY: Florida Board or Pr4M•s•lonal Engineers I ? '1 F y1 1 8/20/09 ANCHOR CLARIFICATION RW Certificate Of Authari :a n No. 9613 N - co NO. DATE BY BUCK & FRAME ANCHORING &Z ^.3 -.7 REVISIONS Lyndon F. Schmidt. P.E. No. 43409 ® 2009 R.W. 9u1LDIN0 CONSUCT•Nre INC. Ft e) . oml FNdner4Dmj 17n1 ann,pf l ]7a,11 owRr f)rruin0c,F1.5114W .5114A 1 dus r 1 • 0 0 Z T C) Oo Y N N O. 1. A W N -o Co V O. 0 A W N -+ 0 O 2 z 5§ n N N N ; 5 ‹P Z- Z C C C C C C C i9 A n n 77pp O �7o`t Io�1 X0ar{71 il P1 R � 2 C Sm T �y D ITt 070000 00 77 W R n V n &0 2 ^ Z Z ZZ Z II N � y Z O < - < <K K< Y v T , J) Po O A 1 P R N Y n PA r= N \ ?1, z l ,„, n 8Z O\ m Z� �r z0 Oy ,7,- 34 -0 W a n 3T °. r 070" �a y c�Z ; Z g 8 o G 1 r1 1 a 2 m n F 1.736" 1 . o m a 2.196 g C L � 1 RI n `< G y O N N y 07 , 4 N H-1 A A 0 70 70 1 N A , Cj O [I= 0 R w i , 0 ' m 0 0< nn N 2 m I 0.461" > U } O 0.360 M o A r n D t ` 1 A m r �...,...5 m Tro m 1 ' 1 - ' - O y ° b w 1 g r O L ° N o 1 070" f T 0.047 1 .177' 1.352' 1.358" - 1 F 1 : a :-.. r c=1==, ,...„ �0 m 070 ^v3 171 N r m zi — 2.14" ---1 r 4 r s 3.06" s f � PRODUCT: Oo cum.nt. Pr.par.d B T �p BUILOINO CONSULTANTS, INC. N I DOUBLE HUNG WINDOW g4 BUILDING Box 230 Volrloo FL. 33595 ,, ? N ' • Phone No.: 513.559.9197 $ y \ 2 03/18(10 ANCHOR CORRECTION JK PART OR ASSEMBLY: Florida Board of Prof...Ional Engineers NO, DATE OI09. ANCHOR CLARIFICATION RW Certificate Of Authorisation No. 9513 BY BILL OF MATERIALS_�� 9 REVISIONS &COMPONENTS Lyndon F. Schmidt, P.E. No. 4 © 2009 R.W. BUILCINC CONSULTANTS INC. R: \A - Projects \Project Folders\Proj 1201 - 1300 \pf 1273 \D. RWBC Drawings \FL - 8134 \FL- 8134.4.dwg, IF 4 •rl :4. W h) N u, A rJ N -. r. CD N H (T (B --I a ( p(D o a N 3 o CO? m 9. 01 < -1 7 CD C N 0 " R rn R c 1 tor 8 O r r0 N . �. N CD 7. O C v CD (p 3 o W C r g 9• 0 0 1 co O a CA (p -- - j n ,- 0 a yeN g �7 „.0 nab c- -i c- v v `§ : 5 T.0 Q 3 g o'a 2g N O o ' Z o 7c0 = N o s c g N s0 go a Qrn o o � m o ° - - rn .0 >n >n � . m . 2 ° 7: c c g Z rn `-i o to Pa >° a a a m 3 '0 7 < 3a m g 0 =c0 aaN co 0 7� e- s =g ma m a 3 z rnfll x C co 0 C 0 8 • o 3 cg can Q 1"� R to o o c o 6. a o ( 3 n a` 0 r Vi a 0 0 0 — 7 Z N i a O 0 N c v '_ W ee.. a= ti 3 O .o <g, O On co - 0 7 CQ > CD 3 .5)- n (D S O C = -n« n-. a 3 7 pee Fr; .2 c-a— o -, . 0 8- co e W W (n A A N D` P N A A N 8 8 8$ 8 8 3 ,0 x x k x x x Z 0- V a. P V 8 8 8 8 8 8 Z - 84.00' MAX. OVERALL FRAME HEIGHT - -- -- - - - - - -- . O N O . O N ) .. T A A b 'O 0 '0 'a '0 '0 / i N W N N W ( 8 P A A O 01 A W ya�, 0 O pp . O A , , . N 0 01 . 41i .... P. (0 C N , 0 '0 V v , o r A $ x x x x x x Z r 3; d O w A W a0 0 rn O X X • N N N N N 0 z O� 2 D + + + + + p + / - _\ CI. 0 o ccn o to Y ' 0 0 o c o o TM . ao H : M H O. CA A V1 A N 0 , n 0 0 0 0 o v/ A ^1 0 0 0 0 0 o Z !y zpp 1 * N PRODUCT: Document. Pr.parod By: =1 BUILDING CONSULTANTS. INC. j E tl V DOUBLE HUNG WINDOW P.o. Ba. 230 Valrico F t. 33598 I "' Cb Z Ph o n e No 813 N $ ca r- -1 PART OR ASSEMBLY: Florida Board of Profeeelonal Engineer. { . D N \ Certificate Of Authorization No. 9813 i . ' r 8 NO DATE BY TYPICAL ELEVATION, DESIGN 4?-v- rL g REVISIONS PRESSURES & GENERAL NOTES Lyndon F. Schmidt, P.E N o. 4 o 2009 R.W. Bu1LO!Na CONSULTANTS INC. !IAA - Projects \Project Folders \Prof 1201- 1300 \pf 1273 \D. RWBC Drawings \FL - 8134 \FL- 8134.4.dwg, 2F Ilillif. . ,. N N O ! J I II O ; W ; i ° ,�I a , ii. I ,,\ 41110 40 0 � 0 vi cn ,,u_: , d� 0 ..- p z i J, a III 1 ©10 ® O H o�� 4D a l l ` N Nw � QL— ,m r „ z Z � 1. o Ri 2 =� I 0 ^ t om �, �m afillia, . A a f Qp � �, � m m A (l � Z ll • 70 7N D o ig v O Om 0 Ao0 (n D © p Z = 3 A en o • ! O� �o N y a 2 ) C1 ' n 0 i 0 0 0 zom 0 A e O O s\‘‘,..\\‘‘‘,\‘‘ is SI ; r e — =El - 'I'-' !!;:‘ lie"4 -I] n 1.. ..... :.. ..... 4 .... , 4 D to e _ ncin; �, I=iu ki a�l r� O r#1111 0 a rn LI © 1 -1/4" MIN. p EMB. (TYP.) mR z ri PRODUCT: Document. Prepared By: CD BUILDING CONSULTANTS. INC. IN Z N DOUBLE HUNG WINDOW �� /Ph No 2 VoIrI9.0 X595 $ C Y i (7, PART OR ASSEMBLY: Florida Board of Pre».eional Engineer* ICe a in co NO, DATE BY VERTICAL & HORIZONTAL Certificate . Dr Avt ori:onan o. Seta CROSS SECTIONS REVISIONS Lyndon F. Schmidt, P.E. No. 43409 3400 ® 2009 R.W. BLnLOINa CONSULTANTS INC. R: \A - Projects \Project Folders \Prof 1201- 1300\pf 1273 \D. RWBC Drawings \FL - 8134 \FL- 8134.4.dwg, 3F S CI II 41:1 i A (--1) ♦ ,•• vv, 171 • n ^ O . c! i : ��1 . N .� v • to � - Co o �o o > Z t� y i :- °'Z z rn z * rr,. u3 X a r- , oR Z --D. 0 n O D , m - D > z 0 m D m Z z r =3 morn N z _A00 ODD ,, D m 0 n © 0 li )1 d: 0 LIK v or) rn 2 ri • P. n 2 O . .. n ,�' Z E ��� ©gym m- z i P. r... -+ y m N 4 r 61 a ,'` _ A • rg .P . • O e 1 t - ` 0 0 C to -_= Z Z .i o Q .'Ql �, x m © ..:. -,� y W aG --I d. .P .♦ y O ' z • • •d E. U� 9, 1 T x x PRODUCT: Document* Pr.par.d By: r"" 9 :9 _. 7 � / BUILDING CONBULTANTS, INC. 1 ('' 40 Z PART OR ASSEMBLY: S. Certificate HUNG WINDOW YY P.O. n o e N? IrI 9197 33595 p y - :_i F lorida Board of Prof.Engineer. l Engineer. Y y �` rtiflcat. Of uthorizatto No. 9817 I N0, DATE BY VERTICAL & HORIZONTAL 7- vG q ,. p REVISIONS CROSS SECTIONS Lyndon F. Behmidt, P.E. No. 47109 C 2009 R.W. BUILDING CONSULTANTS INC. R: \A - Projects \ Project Folders \Pro) 1201 - 1300 \pf 1273 \D. RWBC Drawings \FL - 8134 \FL- 8134.4.dwg, 4F 1 W N —. n y Q Stio;c'o z n o Z 2 r 3 ° m c n O n O M °c morn n ye j < 0 n D • ,m, °yypn2 f co m 2 C' mm D CD m O ° S A 3 3 3 a � 3 ffi 3 °. Ig • 3 3 30° - -4 II I A A E . O • p : O N 4., —1 tom-' o (D O H z O CD a -t 3 3. 0 3 02 aa 3.0 N N j . 3 O Q m . r 1 '.. 70 rri; ° g O a Z A <D m ' ° g �< c n GS 21 O3 2 m M m: aa) 5 m '.' $ am a P , D 1_ 1 I_ _Al FA. O!' O N O a gn m no\ a 7070 C A ° 3 o D _—' m D I o n j z j n m W A Ins 2 mF' o Z 0 x -2 z 0i c 7t C X D _ Z Z C) i in o 6„ • 3 ., ■ ,;o M 3" 3" A_ �� R n Yc A `y O Q Z A 9C oo g PRODUCT: Document. Prepared By r te ' .. � B UILDING CONSULTANTS, INC. � 4. CO € DOUBLE HUNG WINDOW J P.0. 90.23o valnoo FL. 33595 2 N Phone No.: 913.659.9197 q W r - y Cr PART OR ASSEMBLY: Florida Board of Proleesionel Engineer I � N r N O Certificate Of uthorI otio No, 9813 NO. DATE REVISIONS BY BUCK ANCHOR 1' /, OQ Lyndon F. Schmidt, P.E. No. 4340 ® 2009 R.W. BuILO,NO CONe0LTANTe INC. R:\A - Projects\ Project Folders \Pro) 1201- 1300\pf 1273 \D. RWBC Drawings \FL - 8134 \FL- 8134.4.dwg, SF o C r . = , a Co v l o- N s w r-, _ o ..o m ., D (re s w Iv — 3 r- x m m co D m N tO tt • v [ CI c 2 H A m O m O WO m� O O �� O v u m � � -N x _' It — — N �" O O N Z c Z m rD !l p A D - ^' s x p � ' N • � x O �1 n Z 2 I�r7J 0.060" ?° z O a rn 3 a Qro D m a m rn Z P° �' r� n r% y n r� rn ^' D m (� m m r A m A D i nn (_ O N? N a 0 < x -roi y ZZ A Z m Z O D Z 0 0 r 0 Z S ` . : A o_ �- O r'' G � O O D'Om —H 104 0 m 0 D mZ D O 0 N c 0715" o M� i D ,T mO'^ <_vD. D m= n Z k'; c A �O `- - n nn Z Z0 A 0K ' -' i - 7 n Z m r" A m O m n m N n m - 'm D> K m O O zz O C 1.87T'� n,,,, m° 1 O O .. A = A n A z - 5 7 F 4 1 0.079° v n A,c„ O _ N ^ O Z ° y A o a ,Dr -� a F n z 1.327" I--- u o o A p z O D ti n N 1 D x I m A m A �® A Q Pi Ii. m o 0.050' -�{� • O L._ 0.461. c m A 70 A A A A A A �o < n N GlNNG1C)G1L)G) N GIG)G� O G ) NNG O O Z 6 O n ^ � m �� � O � O � m Q — m m r- r v m O O m v v - 0 -o ^' O A I O A r- K m n r n n n n n n n n n r " z -i } z 0.265" 0 n 3.250" - m s Z o I 4 ,c]....„_, ii o I I I� 1.630" � -{ 1.377" T '= + T o c r J Z L �� 0.079 [ i o 4.087" m I ° 0 F 0.827" I A O to 0.887' 0 rji� V I e r� IF T L . m 7 0 , 1.693 0 0 2.689" o 1.876" o I 4 o- P _ L A y N m ; m m o 0.079" �� 0 = lLO'0 o O O - o?o_ CI \D PRODUCT: Document. Pr.POnd By: R -. BUILDING CONSULTANTS, INC. Ia x m DOUBLE HUNG WINDOW gZ�P.O. Bo. 23o volrmo FL. 33595 2 N Phan. No.: 813.859.9 197 ? :"r U Florida Boord of Prol.lonol Engin.. r- : OR ASSEMBLY: Ith t Grtl /scat. Of Authori><atlon No. 9913 A co NO, DATE BY BILL OF MATERIALS, GLAZING 5Z e9 REVISIONS DETAIL do COMPONENT Lyndon F. Schmidt, P.E. N. 43409 © 2009 R.W. BUILD/NO CONSULTANTS INC. }/' � y, 110 Cypress Plaza Drive, Ste. 405 Jacksonville, FL 32256 � - FL STATE (904) 443 -7001 - �t ��, 888 C3`r \ CBC 1250321 (800) 549 -5132 Atelatuagelle, Tote. • Windborne Debris Statement for Home Owner I /WE, (' tr.•sse ( residing at vs' fr .,0 "-5 at-46 , Florida, 3 22 3 Do swear /affirm that we have or are responsible for providing WBD protection at the above address. We do realize that the WBD protection IS required by the State of Florida building codes, as this has been explained to us by the salesperson of Window World of Jacksonville, Inc. OR Do Swear /affirm that we have existing WBD protection that meets the State of Florida building codes, as this has been explained to us by the salesperson of Window World of Jacksonville, Inc: HO R , IC) DATE HOMEOWNER DATE POST A COPY OF RECORDED NOTICE AT JOB SITE. STATE OF FLORIDA COUNTY OF Ot.AL THIS INSTRUMENT WAS ACKNOWLEDGE BEFORE ME THIS - t day of .0 . 20 Known Personally Or Identification t_— Type of Identification Notary Public )J` — f Ast e.v es �; ` CARLA JEAN PROBST °. ' tdYCOM rvtf$SlOiilipp955269 • EXPIRES` tat ttaiy 25, 2014 Wood Pm NotatyPutuicunderwriters. `,A r-- l Ai -ea.. Die' 42/ • (Name of Notary, typed or printed) (Commission Number and Expiration Date) .11.\f -4, City of Atlantic Beach APPLICATION NUMBER Building Department , 800 Seminole Road (To be assigned by the Building Department.) a .• Rr Atlantic Beach, Florida 32233 -5445 G °" Phone (904) 247 -5826 • Fax (904) 247 -5845 a�•- ri 1%' E -mail: building- dept @coab.us Date routed: cR o* / 0 City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: h'/' Y l kJN � Lin 6 ent review required No Y 9 Building Applicant: ) / - 17Pn iv 064/a D 1 Zoning Tree Administrator Project: Al/ by b...5 NT Public Works Public Utilities Public Safety Fire Services te 4 hh E �'` teWa fi rJr : o- . d + g nafur ,i r' , R a Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPI ATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle o .) Comments: 1 UILDIN PLANNING & ZONING Reviewed by: Date: /Z- TREE ADMIN. Second Review: ['Approved as revised. ❑Den d. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. Comments: Reviewed by: Date: Revised 05/14/09