Loading...
Permit 2039 Selva Madera Ct 1020 relocate kitchen 4r f* CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 it tp Application Number . . . . . 10-00000161 Date 2/19/10 Property Address . . . . . . 2039 SELVA MADERA CT Application type description RESIDENTIAL ADDITION/ALTERATION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 50000 ---------------------------------------------------------------------------- Application desc RELOCATING KITCHEN INTO EXISTING SCREEN PORCH AREA ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LEBLANC MATTHEW & CATERINE REDSTONE BUILDERS 2039 SELVA MADERA CT. 2105 EVENTIDE RD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32259 (904) 591-0332 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE II-A Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE A ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 300 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 50000 Expiration Date . . 8/18/10 ------------------------------------------------------------------- ------ Special Notes and Comments *2007 FLORIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . l 2007 FLORIDA BUILDING CODE - RESIDENTIAL. �1 2005 NATIONAL ELECTRICAL CODE. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 300 . 00 300 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 300 . 00 300 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. z� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 10-00000172 Date 2/19/10 Property Address . . . . . . 2039 SELVA MADERA CT Application type description WINDOW AND/OR DOOR Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 4200 ---------------------------------------------------------------------------- Application desc NEW WINDOWS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LEBLANC MATTHEW & CATERINE REDSTONE BUILDERS 2039 SELVA MADERA CT. 2105 EVENTIDE RD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32259 (904) 591-0332 ---------------------------------------------------------------------------- Permit . . . . . . WINDOW AND/OR DOOR PERMIT Additional desc . . Permit Fee . . . . 75 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 4200 Expiration Date . . 8/18/10 ---------------------------------------------------------------------------- Special Notes and Comments *2007 FLORIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2007 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 75 . 00 75 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH — 600 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 1■O- :y OFFICE:(904)247-5x26•FAX NO.:(904)247-5645 VNM/.COAB.US BUILDING PERMIT APPLICATION DUVA m2vAw= ,ON'�taXK?Rk; � _ :3:se rmoi�IDER oor COUNTY 26S S Selvq �y�d Zo0=ov fa'-C,I rt G A DESCRIPTION ;�. ,t*Ae. a : 6 GLASS OFyyORK '.fir � 9 t s # Bi`USEDFSTRUGTURFM,�`'T ❑NEW BUILDING ❑DEMOLITION ❑RESIDENTIAL LOT2Z BLOCK SUB DIVISION SC IV-q Nc,r}C ❑ADDITION ❑CONVERTING USE ❑COMMERCIAL �'jTDESCR1PPONI'OF,WOR ��°�3� .) . a '� v' ?), T e rr ❑ALTERATION 11ACCESSORY BLDG. kIFIRESI�RINKLER•«... r RC ' G ern+a nk �,�✓i✓�� ❑REPAIR ❑POOL/SPA ❑YES ❑N/A C�dJs ❑MOVE ❑OTHER ❑NO PROPERTY.OWNER*, 4ONCTOR.W ti ; %� �RCHITEG3(,ENGINEER„ r��;t 9.NAME. 15.COMPANY NAME: 23.COMPANY NAME: ideT3 16.NAME: 24.LICENSEE NAME: J�.sF�r �1tOMhlat� 10.ADDRESS: 17.STATE OF FLORIDA LICENSE NO.: 25.STATE OF FLORIDA LICENSE NO.: Ge- I L 2'I 16.A D SSSS�k R(' 13 N #u^2 J 7 26.ADDRESS: Je.x FL 32259 11.OFFICE PHONE: 12.FAX NO.: 19.OFFICE PHONE: 20.FAX NO.: 27.OFFICE PHONE: 26.FAX NO.: 13.CELL PHONE: 21.CELL PHONE: 29.CELL PHONE: T&III —541-0332 14.EMAIL ADDRESS: 22.EMAIL ADDRESS: 30.EMAIL ADDRESS: E SIMILE TLE,HOL ER ( s x .Sa �( bri`bwrilzlxlCOONt?A + A�{TORTE LENDER ,,,��,. .. ., m r 7;�x. 31.NAME: 33.NAME: 35.NAME: 32.ADDRESS: 34.ADDRESS: 36.ADDRESS: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6) months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks, Air Conditioners,etc. OWNER'S AFFIDAVIT- I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning.I will not occupy or use the referenced building or any part therof, until all inspections are finaled and prior to obtaining a certificate of occupancy or completion issued by the building official,as required by law. r WARNING TO OWNER: * YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. E AGE w CO RACrTO ' W n.: . ., f v ottorn „�. 9�y atlas T re ` Signeq(~ Date: �'�is a Signed: Date: rf U Before me this day of 2010 in the county of Before this ay of ,a10 in the county of Duval,State of Florida,has personally appeared Duva ate of Florida,has personally appeared CaAerine. A./U. Le6j�fiZr e,r7N Lorhetf herin by*imI elF/herself and affirms that all statements and declarations are herin by himself/herself and affirms that all statements and declarations are true and accurate. true and accurate. �+,/� �.w... Notary Public at Large,State of FLDRlAR,County of 'DuV A L Notary Public at Large,State of /"' County of I ❑Personally Known 11 Personally Known ^L /� C� �(2 3 FZ/7 �l Produced Idenf ratio - + �9roduced Identificat' (--t-// / `l T c� Notary Signature .q�_ Notary Signature: a `. r ® p Y REVIEWED FOR CODE CO Q3 �t I eoww NHITE , 1"ry¢,• PAIR IA A.JINK F ATLANTIC B �Iv c tvt1SS10N#DD 634126 W Bldg Permit App aTieh Com sion DD 87F�8�E RMIT'S FOR ADD %•• q�°' I IRE. Expire ►�aya�,`�� hruNc,..,vFuhlroUnderwnters Rf,ka• Bwdad Troy Fo n In:ur. eoo QUI MENTS AND CONDI �•..,. - __ .r.. L� REVIEWED DATE:v2'/7_/D k CITY OF ATLANTIC BEACH PRODUCT APPROVAL SPECIFICATION SHEET (short form) As required by Florida Statute 553.842 and Florida Administrative Code 96-72,please provide the information and approval numbers on the building components listed to be utilized on the construction project for which you are applying. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Statewide approved products are listed online @ www.floridabuilding.org Category/Subcategory Manufacturer Product Description FL Approval#(s) EXTERIOR DOORS a. Swinging b. Sliding c. Sectional/Roll Up d. Other WINDOWS a. Single/Double Hung Sr�t,Cr�;,.e c AceYne-4- W;-40u.> l�L /Zoev. I 2ocy. 2-- b. b. Horizontal Slider c. Casement d. Fixed _ -/0 e. Mullion f. Skylights g. Other PANEL WALL a. Siding b. Soffits c. Storefronts d. Glass Block e. Other ROOFING PRODUCTS a. Asphalt Shingles b. Non-Structural Metal c. Roofing Tiles d. Single Ply Roof e. Other STRUCTURAL COMPONENTS a. Wood Connectors b. Wood Anchors c. Truss Plates d. Insulation Forms e. Lintels f. Others NEW EXTERIOR ENVELOPE I understand that,at the time of inspection,the following information must be available to the inspector on the jobsite: 1. A copy of the product approval. 2. The list of performance characteristics which the product was tested and certified to comply with. 3. A copy of t e applicable manufacturers'installation requirements. Further,I rstand roduct may have to be removed if approval cannot be demonstrated during inspection. plicant Signature Date H:/Product approvaf spec sheet short form.xfsx � City of Atlantic Beach APPLICATION NUMBER BuildingDepartment Pa (To be assigned by the BrtJiiding Department) 800 Seminole Road r� Atlantic Beads,Florida 32233-5445 Phone(904)247-5828 • Fax(904)247-5845 / D;,icE-mail: building-deptGooab.us Date routed: City web-site: httpJ/www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: s -3 7 C`l�a�� ads Via- Deinrtment review required Yew No uildin Applicant f� � S Ing&Zoning Tree Administrator Project: 1-4 2) l!() Public Works Public Utilities Public Safety Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verifred B Florida Dept of Environmental Protection Florida Dept of Transportatlon St Johns River Wates'Management District Army Corps of Engineers Division of Hous and Restaurants Division of Alcoholic Beverages and Tobacco Other. APPU ATION STATUS Reviewing Department First Review: proved. ❑Denied. (Circle one.) Comments: =BUILDING PLANNING&ZONING Reviewed by: Date:a-17—/0 TREE ADMIN. Second Review: QApproved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. [Denied. Comments: Reviewed by: Date: Revised MUM �a►`i City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road l /& . � Atlantic Beach,Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 yJ� � 0I E-mail: building-dept@coab.us Date routed: // /y City web-site: http:ltwww.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address- y cS4"vt- /lit Department review required Yes No -o+�'%T Building Applicant` Planning&Zoning Tree Administrator Project: ?� Public Works Public Utilities Public Safety Fire Services Review fee$ .E?ept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Amry Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Toba= Other: APPLICATION STATUS Reviewing Department First Review: proved. QDenied. (Circle one.) Comments: �BUIL�NG PLANNING&ZONING Reviewed by: `� Date: '�'/7'ta TREE ADMIN. Second Review: nApproved as revised. ❑Den ed. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05!14108 F CITY OF ATLANTIC BEACHAO�800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 1 > OFFICE:(904)247-5826•FAX NO.:(904)247-5845 J' W W W.COAB.US BUILDING PERMIT APPLICATION DUVAL COUNTY 1.JOB ADDRESS: 2.VALUATION OF WORK: 11 SQ:FT.UNDER ROOF 20`37 d LEGAL DESCRIPTION: 5,CLASS OF WORK: 6.USE OF STRUCTURE: ❑NEW BUILDING ❑DEMOLITION ❑RESIDENTIAL LOT?jBLOCK_SUBDIVISION °k&ot ya t-3411 ❑ADDITION ❑CONVERTING USE ❑COMMERCIAL 7.DESCRIPTION OF WORK ❑ALTERATION ❑ACCESSORY BLDG. 8.FIRE SPRINKLER: ' i 1 „ A I I t �, ❑REPAIR 13POOL/SPA 13 YES 13 WA 'rC c C ❑MOVE ❑OTHER ❑NO PROPERTY OWNER: CONTRACTOR: ARCHITECT/ENGINEER: 9.NAME: 15.COMPANY NAME: 23.COMPANY NAME: Cc k.e i3urljes 16.NAME: 24.LICENSEE NAME: J4 n 10.ADDRESS: 17.STATE OF FLORIDA LICENSE NO.: 25.STATE OF FLORIDA LICENSE NO.: 2c�3� sets r�� c(3c 1?- 52 II 18.ADDRESS: qk5 Sl,,k ( 2 I 2 " 26. Y FL 3 2 2 6 s 1W PPP I 01"I M 11.OFFICE PHONE: 12.FAX NO.: 19.OFFICE PHONE: 20.FAX NO.: 27.ffHCE N .. 13.CELL�60,PHOZ5"� L 37 D 21.CELL tj-5 SI--0 29.lby PHONE: 14.EMAIL AD0 ESS: 22.EMAIL ADDRESS: 30,EMAIL ADDRESS: a { 2f0e wv..'� c ��slbtilld��s�© b�Ilsa FEE SIMPLE TITLE HOLDER: (IF OTHER THAN ONMFJ2) BONDING COMPANY: MORTGAGE LENDER: s. 31.NAME: 33.NAME: 35.NAME: 32.ADDRESS: 34.ADDRESS: 36.ADDRESS: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six(6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks, Air Conditioners,etc. OWNER'S AFFIDAVIT-I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I will not occupy or use the referenced building or any part therof,until all inspections are finaled and prior to obtaining a certificate of occupancy or completion issued by the building official,as required by law. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORAflMnORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NER or AGENT CONTRACTOR Ag t,P er of Attorney or Agency Letter Required) (Qu 'er Only) Sig,-8-1 Date: i O Signed: Date: /U /O Befor this day of { ,2010 in the county of Before me is day of ,2010 in the county of Duval,State of Florida,has personally appeared Duval,7toforida,hasappTred Ma �a � �e��nc herin by himself/4umseltand affirms that all statements and declarations are herin by self/herself and affirms that all statements and declarations are true and accurate. If'-`, true and accurate. Notary Public at Large,State of rVrt C' ,County of bo CL Notary Public at Large,State of / ,County of-IL a Personally Known 1 V 1 ` L 9-4f a 513 ❑^Personally Known UPIS'duced Idents ti I, t►Yr•roduwd Iden 0-6-631V) Notary Signature: Notary Signatu REVIEWED FOR �l` CITY OF AV A'NTIPENNYru� EY @$ .i N �tl; i Bldg Permit Application 20 „f •� Commissions#DD 1672 SEE PERMITS } "°"' "" Expires April 26, 3 REQUIREMENTS AN I QUIREMENTS AND CoDITIONS. 6a,dltlnMYnoypWi eo9-aWrels ir"�", D BY: -' DATE: ' 4 FORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Addition,2039 Selva Madera Ct Builder Name: Redstone Builders Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 b.N/A R= ft2 7. Windows Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap: 18.0 kBtu/hr SHGC: SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC: e. U-Factor: N/A ft2 a.Electric Heat Pump Existing Cap: 18.0 kBtu/hr HSPF:7.7 SHGC: 8. Floor Types Insulation Area 14.Hot water systemsa. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 1 hereby certify that the plans and specifications covered by Review of the plans and $7,4 this calculation are in compliance with the Florida Energy specifications covered by this AV 1 p Code. calculation indicates compliance '06, with the Florida Energy Code. PREPARED BY: —_ cxaa;r. �lis Before construction is completed DATE: —_ 7 `) IO this building will be inspected for compliance with Section 553.908 *� I hereby certify that this building, s designed, is in compliance Florida Statutes. with the Florida Energy �4b W'E.'T OWNER/AGENT: ____ _ BUILDING OFFICIAL: / 7 DATE: __ ? ° DATE: -l7-io 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 1 of 5 PROJECT Title: Addition,2039 Selva Madera C Bedrooms: 0 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 312 Lot# Owner: Total Stories: 1 SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Redstone Builders Rotate Angle: 0 Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 75 70 1281 49 Medium FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulation 50.5 ft 0 312 ft2 0 0 1 ROOF / Roof Gable Roof Solar Deck \/ # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 338 ft2 0 ft2 Medium 0.96 No 0 22.6 deg ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 312 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly(Vented) 19 338 ft2 0.11 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type Cavity Area R-Value Fraction Absor. _ 1 E Exterior Frame-Wood 11 130.5 ft2 0.23 0.75 2 N Exterior Frame-Wood 11 193.5 ft2 0.23 0.75 3 W Exterior Frame-Wood 11 130.5 ft2 0.23 0.75 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 2 of 5 a DOORS # Ornt Door Type Storms U-Value Area 1 E Wood None 0.460000 20.09999 WINDOWS Orientation shown is the entered,asBuilt orientation. Overhang _# Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 E Vinyl Low-E Double Yes 0.4 0.4 N 15 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None 2 N Vinyl Low-E Double Yes 0.4 0.4 N 30 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None 3 N Vinyl Low-E Double Yes 0.4 0.4 N 9 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None INFILTRATION&VENTING ----Forced Ventilation---- Run Time Fan Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts Default '! 0.00036 295 6.30 16.2 30.4 0 cfm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR-Ducts--- 1 ucts_1 Central Unit None SEER: 13 18 kBtu/hr 540 cfm 0.75 sys#1 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF:7.7 18 kBtu/hr sys#1 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----supply---- ----Return---- Air Percent �j # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 i Attic 6 42.4 ft2 Attic 15.6 ft' Default Leakage Attic (Default)c (Default)% 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 3 of 5 TEMPERATURES Programable Thermostat: None Ceiling Fans: Cooling Jan [X Feb ]Mar X Apr May [X]Jun X Jul X Aug [X Sep X Oct (X Nov (X Dec Heating IX Xj Jan [X�Feb IX X]Mar f X1 Apr lxxi May [X]Jun f X�Jul EX�Aug [X�Sep EX�Oct [X�Nov EXi Dec Ventin X Jan [X Feb X Mar [X A r X Ma [X]Jun [X Jul [X Au [X Se [X Oct [X Nov X]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/11/2010 8:52 AM EnergyGaugeO USA-FlaRes2008 Page 4 of 5 FORM 1100A-08 Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 2039 Selva Madera Ct PERMIT#: Atlantic Beach, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows& Doors N1106.AB.1.1 Maximum: .3 cfm/sq.ft. window area; .5 cfm/s .ft.door area. _ Exterior&Adjacent Walls N1106.AB.1.2.1 Caulk, gasket,weatherstrip or seal between:windows/doors& frames, surrounding wall;foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations; between wall panels&top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is / installed that extends from, and is sealed to,the foundation to the --------------- - _ _�_tom plate. Floors N1106.AB.1.2.2 Penetrations/openings> 1/8"sealed unless backed by truss or joint members. / EXCEPTION: Frame floors where a continuous infiltration barrier ✓ is installed that is sealed to the erimeter, enetrations and seams. Ceilings N1106.AB.1,2.3 Between walls&ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board &top plate; attic access. / EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams! Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation; or Type IC with <2.0 cfm from conditioned space, tested. Multi-story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavit between floors. _ Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker(electric) or cutoff(gas) must be __provided. External or built-in heat tra re uired. Swimming Pools&Spas N1112.AB.2.3 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer. Gas spa&pool heaters must have a minimum thermal efficiency of 78%. _ Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. _ Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for ii each system. Insulation N1104.AB.1 Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both / N1102.B.1.1 sides. Common ceiling&floors R-11. �/ 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 83 The lower the Energy Performance Index, the more efficient the home. 2039 Selva Madera Ct, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 3. Number of units,if multiple family 1 b.N/A R= ft2c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 7. Windows** Description Area b.N/A R= ft2c.N/A R= ft2 a. U-Factor: Dbl,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11. Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap: 18.0 kBtu/hr SHGC: SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC: e. U-Factor: N/A ft2 a.Electric Heat Pump Existing Cap: 18.0 kBtu/hr SHGC: HSPF:7.7 8. Floor Types Insulation Area 14.Hot water systemsa. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building TIDE ST Construction through the above energy saving features which will be installed (or exceeded) 01 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code nt fe ures. f�, „a " �`0 Builder Signature: _ _ Date: 2 12 1 Address of New H e: -203 -5c-l✓,� City/FL Zip: Ah� � � r�, � WE *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA- FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge®USA-FlaRes2008 r Project Summa Job: + -•wrightsoft, Date: 2/10/10 Entire House By: M.Ellis Energy Design Systems, Inc. Project I • • For: Addition 2039 Selva Madera Ct, Atlantic Beach, FL Notes: Door of new addition faces East. Existing 1 1/2 ton HVAC unit currently servicing Master Suite will also service the new addition as well Design Information Weather: Jacksonville, Int'I Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 93 OF Inside db 72 OF Inside db 72 OF Design TD 40 OF Design TD 21 OF Daily range M Relative humidity 50 % Moisture difference 56 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 7500 Btuh Structure 5049 Btuh Ducts 613 Btuh Ducts 871 Btuh Central vent(35 cfm) 1539 Btuh Central vent(35 cfm) 808 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9653 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 6594 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 574 Btuh Ducts 212 Btuh Heating Cooling Central vent(35 cfm) 1342 Btuh Area(ft2) 312 312 Equipment latent load 2128 Btuh Volume(ft') 2808 2808 Air changes/hour 0.61 0.32 Equipment total load 8722 Btuh Equiv.AVF (cfm) 29 15 Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond Coil Efficiency 0 HSPF Efficiency 0 EER Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 292 cfm Actual air flow 292 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.76 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. f, -44- wrightsc►ft` Right-Suite Residential 6.0.119 RSR29784 2010-Feb-11 08:39:20 GK E:\EDS\Current\Residential Manual J\Redstone Bldrs,Addition,2039 Salva Madera Ct,Atlantic Bch.rr Page 1 CITY OF ATLANTIC BEACH PRODUCT APPROVAL SPECIFICATION SHEET (short form) As required by Florida Statute 553.842 and Florida Administrative Code 913-72,please provide the information and approval numbers on the building components listed to be utilized on the construction project for which you are applying. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Statewide approved products are listed online @ www.floridabuilding.org Category/Subcategory Manufacturer Product Description FL Approval#(s) EXTERIOR DOORS I� �l l 6-Z a. Swinging , S b. Sliding c. Sectional/Roll Up d. Other WINDOWS a. Single/Double Hung 51 Keri,me Ive", &,,15V C60 b. Horizontal Slider c. Casement d. Fixed e. Mullion f. Skylights g. Other PANEL WALL a. Siding b. Soffits c. Storefronts d. Glass Block e. Other ROOFING PRODUCTS a. Asphalt Shingles b. Non-Structural Metal c. Roofing Tiles d. Single Ply Roof e. Other STRUCTURAL COMPONENTS IYA a. Wood Connectors b. Wood Anchors c. Truss Plates y d. Insulation Forms �0 e. Lintels f. Others NEW EXTERIOR ENVELOPE I understand that,at the time of inspection,the following information must be available to the inspector on the jobsite: 1. A copy of the product approval. 2. The list of performance characteristics which the product was tested and certified to comply with. 3. A copy of the applicable manufacturers'installation requirements. Further,I urstand a product may have to be removed if approval cannot be demonstrated during inspection. plicant Signature Date H:/Product approval spec sheet short farm.xlsx IZ 0 -+-C), 0 g , S a Silver Line -----� = ° WIND0WS • D00RSFFEB _ N1w an Andersen Company 1 SILVERLINE DRIVE. NORTH BRUNSWICK,NJ 08902 - ` SERIES.2200 - MODEL 2202 752Y MAX OVERALL FIN WIDTH EXTRUDED VINYL 72.00'MAX.OVERALL FRAME WIDTH TWIN SINGLE HUNG WINDOW 3 W/ NAILING FIN �W "NON-IMPACT' O = m � r_J Vt W W GENERAL NOTES - � a a 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code (FBC)structural requirements excluding the Iiigh Velocity Hurricane Zone"(HVHZ). O a 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to g base material shall be beyond wall dressing or stucco. h 3. When used in areas requiring wind borne debris protection this product is required to be X X z o protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. V) 15 4. Site conditions that deviate from the details of this drawing require turther engineering o analysis by a licensed engineer or registered architect. ri u 2 i Q W = e 2 TABLE OF COMEMS z air: 1128109 1 Typical elevation.design pressures 3 general notes � �A N.T.S. 2 Horizontal S vertical doss sections AL 3 Horizontal a vertical cross sections - - - a«.W. LFS ; 4 Buds a horn°anchoring75.25"x 7s.25" 72.00"x 72.00" 31.69"x 28.00" G1 +25.0 -25.0 murno No.: a S Billof materials, m detail d coponents FL-12068.6 °o e S swzr 1 a� Q c SilverLine- 'A" i N (J ll W S * D 0 0 R S � �\W r- J� 8 Y:^.S ;t i 51.25 MAx.OVERALL FRI w7�j .19 9 d r r 18110"MAX.OVERAII �i�t SILVERLBYE DRIVE, NORTH BRUNSW)CK,NJ 08902 FRAMEWIDTH •z?;.irk 55.25tMX.OV6tALLFIN WIDTH $ � r 5200'MAX.OVERALL 7— a V SERIES 2200 - MODEL 2201 Ftr---- `"°'. . ! EXTRUDED VINYL SINGLE HUNG WINDOW O 3z W/ NAILING FIN o g o T �/ tD "NON-IMPACT' %` � � � x Asn w vii > � p W GENERAL NOTES 1. This product has been evduated and is in compliance with the 2007 Florida Budding Code i (FBC)structural requirements excluding the"High Velocity Hurricane Zone'(HVHZ). 2. Product anchors shah be as fisted and spaced as shown on details.Anchor embedment to base material shah be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product is required to be 3 protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. _ 9 (ORIEL) 4. Site conditions that deviate from the details of this drawing require further engineering c analysis by a licensed engineer or registered architect. MWO1714-11-A �L g 39.25"x 65.25" 36.00'x 62.00' 31.69"x 28.0(' +50.01-4 -50.0 2 e TABU OF COMEHTS z v s SHEET 9 DESCRUTION 55.25"x 76.25" 52.00'x 73.00" 47.69"x 33.50" +30.0 -30.0 arae 1/27/09 2° 1 T elevation, S notes GI Srxe N.T.S. ° 48.00"x 96.00" 43.69"x 28.00"(X) 2 Horizontal 6 vertical cross seclim 51.25"x 99.25' +30.0 -30.0 arc rr: AL m' 3 tlor¢orstal b vertical crosssec8oru (ORIEL) 43.69-X 62.00"(0) aK BY.. LFS ; 5 N of materials.gl aft detail a c nts 51.25"x 87 25" 48.00"x84.00" 43.69"x39.00' +20.0 -20.0 NO"12068.5 a A FL- 0 s 'NOTE:MAX.OVERALL FRAME HEIGHT AND WIDTH OCCUR ON SEPARATE UNITS SrcFr 1 a 5 a 5 Builders Hardware 'nc. 5615 E. POWHATAN AVE ^--'^""' 37.50" MAX. O.A. TAMPA, FL 33610 (7 (� FRAME WIDTH PH. (800) 966-7753 U� i 5 A FEB 12 010 GLAZED FIBERGLASS DOOR z 1NSWINGIUUTSINING By o z NON-IMPACT X M T w Gt N12A1, N, 2 a /'► e t. This product has been evaluated and is in compliance with the �1 2007 Florida Building Code structural requirements excluding the d o "High Velocity Hurricane Zone'. O X 2. Product anchors shalt be as Listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. c�a 3. When used in areas requiring wind borne debris protection this 'a CO Q product is required to be protected with an impact resistant covering that complies with Section 1605.1.2 of the Florida Building Code, 4, For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. °L 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. S OVERALL OVERALL GLASS DESIGN PRESSURE SWING FRAME D.L.O. TYPE " TABLE OF CONTENTS DIMENSION DIMENSION POSITIVE NEGATIVE SHEET DESCRIPTION 37.50" 20.50" t TYPICAL ELEVATION, DESIGN PRESSURES & GENERAL NOTES INSWING X X +60.0 —60.0 2 PANEL DETAILS, COMPONENTS & VERTICAL CROSS SECTIONS 81.63' 62.75" G1 3 HORIZONTAL & VERTICAL CRASS SECTIONS 37.50" 20.50" 4 VERTICAL CROSS SECTIONS OUTSWING X X +60.0 —60.0 5 BUCK & FRAME ANCHORING 80.50" 62.75- 6 JBILL OF MATERIALS, GLAZING DETAILS & COMPONENTS s a. FORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Addition,2 Builder Name: Redstone Builders Street: 2039 Sely ffra Ct Permit Office: Atlantic Beach City,State,Zip: Atlantic B FL,o Permit Number: Owner: , N Jurisdiction: 261100 Design Location: FL,Jack oin:ZA N 1. New construction or existin � N b.N/A R= ft2 (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple fa . gle-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 3. Number of units,if multip c.N/A R= ft2 4. Number of Bedrooms Q� d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 7. Windows Description Area b.N/A R= ft'c.N/A R= ft2a. U-Factor: Dbl,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft' a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft' SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit SHGC: Existing Cap: 18.0 kBtu/hr SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC: e. U-Factor: N/A ft2a. Electric Heat Pump Existing Cap: 18.0 kBtu/hr HSPF:7.7 SHGC: 8. Floor Types Insulation Area 14.Hot water systemsa. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b.N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 1 hereby certify that the plans and specifications covered by Review of the plans and � H S7,4,1, this calculation are in compliance with the Florida Energy specifications covered by this Code. `�y > ,� calculation indicates compliance y r„ a+ W , with the Florida Energy Code. PREPARED BY: Before construction is completed .- DATE: ___ __ Z• 1�• 1 O __ __ _- this building will be inspected for compliance with Section 553.908 _ I hereby certify that this buildjing,4s designed, is in compliance Florida Statutes. AA with the Florida Energy COr)wt.,T OWNER/AGENT:: BUILDING OFFICIAL: DATE: G' _ DATE: _ 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 1 of 5 PROJECT Title: Addition,2039 Selva Madera C Bedrooms: 0 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 312 Lot# Owner: Total Stories: 1 SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Redstone Builders Rotate Angle: 0 Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL-JACKSONVILLE-INT 2 32 93 75 70 1281 49 Medium FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulation 50.5 ft 0 312 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 338 ft2 0 ft2 Medium 0.96 No 0 22.6 deg ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 312 ft2 N N CEILING _#_ _Ceiling Type R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly(Vented) 19 338 ft2 0.11 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 E Exterior Frame-Wood 11 130.5 ft2 0.23 0.75 2 N Exterior Frame-Wood 11 193.5 ft2 0.23 0.75 3 W Exterior Frame-Wood 11 130.5 f12 0.23 0.75 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 2 of 5 DOORS # Ornt Door Type Storms U-Value Area 1 E Wood None 0.460000 20.09999 WINDOWS Orientation shown is the entered,asBuilt orientation. Overhang # Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 E Vinyl Low-E Double Yes 0.4 0.4 N 15 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None 2 N Vinyl Low-E Double Yes 0.4 0.4 N 30 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None 3 N Vinyl Low-E Double Yes 0.4 0.4 N 9 ft2 1.3 ft 0 in 2 ft 0 in HERS 2006 None INFILTRATION &VENTING ----Forced Ventilation---- Run Time Fan Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 295 6.30 16.2 30.4 0 cfm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR___ Ducts 1 Central Unit None SEER: 13 18 kBtu/hr 540 cfm 0.75 sys#1 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF:7.7 18 kBtu/hr sys#1 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air Percent v # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage ON RLF 1 Attic 6 42.4 ft2 Attic 15.6 ft2 Default Leakage Attic (Default)c (Default)% 2/11/2010 8:52 AM EnergyGaugeg USA-FlaRes2008 Page 3 of 5 TEMPERATURES Programable Thermostat: None Ceiling Fans: Cooling Jan Feb [[X]Mar [X]]A r rXj Ma [X Jun X Jul rxi Au Se Oct X Nov [X Dec Heatin �Xj XJan �XXJ Feb [X}Mar [X]Apr May [X�Jun f Xj Jul Aug jxxj Se f X�Oct Ix �Nov EX�Dec Ventin X Jan X Feb [X Mar [X A r may (X Jun [X Jul Au X Se [X Oct Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 4 of 5 FORM 1100A-08 Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 2039 Selva Madera Ct PERMIT#: Atlantic Beach, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows& Doors N1106.ABA A Maximum: .3 cfm/sq.ft.window area; .5 cfm/s .ft.door area. ✓ Exterior&Adjacent Walls N1106.AB.1.2.1 Caulk, gasket,weatherstrip or seal between:windows/doors& frames, surrounding wall; foundation &wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations; between wall panels&top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to, the foundation to the top plate. _ Floors N1106.AB.1.2.2 Penetrations/openings> 1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier _ is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls&ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits,chimneys, cabinets sealed to continuous air barrier; gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier ✓ is installed that is sealed at the perimeter, at penetrations and Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from / insulation; or Type IC with <2.0 cfm from conditioned space, tested. Multi-story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker(electric) or cutoff(gas)must be provided. External or built-in heat trap required. Swimming Pools&Spas N1112.AB.2.3 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer. Gas spa&pool heaters must have a minimum thermal efficiency of 78%. _ Heat _ump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. ✓ Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system._ Insulation N1104.AB.1 Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both N1102.B.1.1 sides. Common ceiling&floors R-11. 2/11/2010 8:52 AM EnergyGauge®USA-RaRes2008 Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 83 The lower the Energy Performance Index, the more efficient the home. 2039 Selva Madera Ct, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= f12 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(f12) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 b.N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 a. U-Factor: Dbl,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 f12 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap: 18.0 kBtu/hr SHGC: SEER:13 d. U-Factor: N/A f12 13.Heating systems SHGC: a.Electric Heat Pum Cap:18.0 kBtu/hr e. U-Factor: N/A ft2 p Existing HSPF:7.7 SHGC: 14.Hot water systems 8. Floor Types Insulation Area a. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b.N/A R= f12 b. Conservation features c.N/A R= ft2 None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building ST Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed .a AN based on installeACOC liantfeatures. 71 `�C4Builder Signatur -�' Date: Z C7 c .W . -,c Cit /FL ZiAddress of NewZG3 1 _ � Ver ,/dad elrt i_— Y p: *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA- FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321)638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge®USA-FlaRes2008 + Wrightsoft Project Summary Date: 2110110 Entire House By: M.Ellis Energy Design Systems, Inc. Project I • • For: Addition 2039 Selva Madera Ct, Atlantic Beach, FL Notes: Door of new addition faces East. Existing 1 1/2 ton HVAC unit currently servicing Master Suite will also service the new addition as well. Design Information Weather: Jacksonville, Int'I Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 93 OF Inside db 72 OF Inside db 72 OF Design TD 40 OF Design TD 21 OF Daily range M Relative humidity 50 % Moisture difference 56 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 7500 Btuh Structure 5049 Btuh Ducts 613 Btuh Ducts 871 Btuh Central vent(35 cfm) 1539 Btuh Central vent(35 cfm) 808 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9653 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 6594 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 574 Btuh Ducts 212 Btuh Heating Cooling Central vent(35 cfm) 1342 Btuh Area(ft) 312 312 Equipment latent load 2128 Btuh Volume(ft') 2808 2808 Air changes/hour 0.61 0.32 Equipment total load 8722 Btuh Equiv.AVF (cfm) 29 15 Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond Coil Efficiency 0 HSPF Efficiency 0 EER Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 292 cfm Actual air flow 292 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.76 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. _} _ Wrigtttsoft Right-Suite Residential 6.0.119 RSR29784 2010-Feb-11 08:39:20 ,C>k, E:\EDS\Current\Residential Manual J\Redstone Bldrs,Addition,2039 Selva Madera Ct,Atlantic Bch.rr Page 1 Ac FORM 1100A-08 r/�I FLORIDA ENERGY EFFICIENCY CODE FOR B ILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Addition,2039 Selva Madera Ct Builder Name: Redstone Builders Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.NIA R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10,Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 b.NIA R= ft2 7. Windows Description Area c.NIA R= f12 a. U-Factor: Db(, U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap:18.0 kBtu/hr SHGC: SEER:13 d. U-Factor: N/A ft2 13,Heating systems SHGC: e. U-Factor: N/A ft2 a.Electric Heat Pump Existing Cap: 18.0 kStu/hr WSPF:7.7 SHGC: 8. Floor Types Insulation Area 14.Hot water systemsa. None a. Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 I hereby certify that the plans and specifications covered by Review of the plans and [1AE S"7 . ' this calculation are in compl'ance with the Florida Energy specifications covered by this Code, calculation indicates compliance �' `` '•rn with the Florida Energy Code. r ', gip PREPARED BY: 7 �p _ Before construction Is completed f DATE ____.__ _.__2 L1_tZ this building will be inspected for + t . compliance with Section 553.908 s I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy COAP. t OWNER/ EN BUILDING OFFICIAL: DATE: Z11DATE: _ � _ 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 1 of 5 Pro ect Summa Dat + Wrightsoft" � � Date: 2!10110 Entire House By: M.Ellis Energy Design Systems, Inc. Project Information For: Addition 2039 Selva Madera Ct, Atlantic Beach, FL Notes: Door of new addition faces East. Existing 1 1/2 ton HVAC unit currently servicing Master Suite will also service the new addition as well. Design Inforrnation Weather: Jacksonville, Int'I Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 93 OF Inside db 72 OF Inside db 72 OF Design TD 40 OF Design TD 21 OF Daily range M Relative humidity 50 % Moisture difference 56 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 7500 Btuh Structure 5049 Btuh Ducts 613 Btuh Ducts 871 Btuh Central vent(35 cfm) 1539 Btuh Central vent(35 cfm) 808 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9653 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 6594 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 574 Btuh Ducts 212 Btuh Heating Cooling Central vent(35 cfm) 1342 Btuh Area (ft') 312 312 Equipment latent load 2128 Btuh Volume(ft') 2808 2808 Air changes/hour 0.61 0.32 Equipment total load 8722 Btuh Equiv.AVF (cfm) 29 15 Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond Coil Efficiency 0 HSPF Efficiency 0 EER Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 292 cfm Actual air flow 292 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.76 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. M '`"P`,- wr1ghtsctiftRight-Suite Residential 6.0.119 RSR29784 2010-Feb-11 08:39:20 .. E:\EDS\Current\Residential Manual J\Redstone Bldrs,Addition,2039 Selva Madera Ct,Atlantic Bch.rr Page 1 0 FORM 1100A-08 FLORIDA ENERGY E N Y CODE FOR BUILDING CONSTRUCTION Florida Departme Colmun Affairs Residential Performance Method A r Project Name: Addition,2039 Selva Mad ,.A Builder Name: Redstone Builders Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(FTom Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 0 d.N/A R= f12 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 7. Windows Description Area b. N/A R= ft2c.N/A R= ft2 a. U-Factor: Dbl,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42,4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap: 18.0 kStu/hr SHGC: SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC: e. U-Factor: N/A ft2 a.Electric Heat Pump Existing Cap:18.0 kBtu/hr SHGC: HSPF:7.7 8. Floor Types Insulation Area 14.Hot water systemsa. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b. N/A R= ft2 b. Conservation features c.NIA R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 ,ft I hereby certify that the plans and specifications covered by Review of the plans and -t)AE S7'A{ this calculation are in compliance with the Florida Energy specifications covered by this Code. QQ,� calculation indicates compliance .[ with the Florida Energy Code. PREPARED BY: fit„ Before construction is completed a p DATE ___-__- _ 2_ Li•-lQ __-- _ _-___-- this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ,r Sa4s ri with the Florida Energ + , OWNER/A NT: BUILDING OFFICIAL: DATE: _ °. — DATE: -- — --- 2/11/2010 8:52 AM EnergyGaugeO USA-FlaRes2008 Page 1 of 5 �z,, �\ FQRPV11100A-08 V `� FLORIDA ENERGY EFFI Co>;Y CO E FOR BUILDING CONSTRUCTION Florida Department of r> `iity airs Residential Performance Method A Project Name: Addition,2039 Selva M t Builder Name: Redstone Builders Street: 2039 Selva Madera Ct Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.N/A R= ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 b.N/A R= ft2 7. Windows Description Area c.N/A R= ft2 a. U-Factor: Dbl, U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit Existing Cap: 18.0 kBtu/hr SHGC: SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC: a.Electric Heat Pump Existing Cap: 18.0 kBtu/hr e. U-Factor: N/A ft2 HSPF:7.7 SHGC: 14.Hot water systems 8. Floor Types Insulation Area a. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b. N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 I hereby certify that the plans and specifications covered by Review of the plans and '011"ST4r this calculation are in compliance with the Florida Energy specifications covered by this � � Code. calculation indicates compliance vYY�a with the Florida Energy Code. ', PREPARED BY: ____ _ 9+ _ENS Before construction is completed DATE: _._.__-__ 2' tQ_ _ _ —__-. ____ _____ this building will be inspected for compliance with Section 553.908 * :_ ✓ 4 I hereby certify that this building, as designed, is in compliance Florida Statutes. V with the Florida Energy Code. X01) a OWNER/AGENT:-----.____._-._ ____ _____ ___—_ BUILDING OFFICIAL:DATE: ----- - ---- -- ---- — - — - — DATE: --- — 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 1 of 5 FOR 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Addition,2039 Seiva Madera Ct Builder Name: Redstone Builders Street. 2039 Selva Madera Ct Permit Office: Atlantic Beach City, State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 454.50 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4 Number of Bedrooms 0 d.N/A R= ft2 5. Is this aworst case? No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft2) 312 a.Cathedral/Single Assembly(Vented) R=19.0 338.00 ft2 b.N/A R= ft2 7. Windows Description Area c.N/A R= ft2 a. U-Factor: Dbi,U=0.40 54.00 ft2 SHGC: SHGC=0.40 11.Ducts b. U-Factor: N/A ft2 a. Sup:Attic Ret:Attic AH:Attic Sup.R=6,42.4 ft2 SHGC: 12.Cooling systems c. U-Factor: N/A ft2 a.Central Unit SHGC: Existing Cap: 18,0 kBtulhr SEER:13 d. U-Factor: N/A ft2 13.Heating systems SHGC a.Electric Heat Pump Ca 18.0 kBtu/hr e. U-Factor: N/A ft2 Existing p HSPF:7.7 SHGC: 8. Floor Types Insulation Area 14.Hot water systemsa. None a.Slab-On-Grade Edge Insulation R=0.0 312.00 ft2 b N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15.Credits None Glass/Floor Area: 0.173 Total As-Built Modified Loads: 10.21 PASS Total Baseline Loads: 12.37 I hereby certify that the plans and specifications covered by Review of the plans and 1H E ST,4 this calculation are in compliance with the Florida Energy specifications covered by this y 4 0 Code. ,1 calculation indicates compliance �,r A,� with the Florida Energy Code. PREPARED BY Before construction is completed DATE: this building will be inspected for 0Ir � - __---- _ x .- � compliance with Section 553.948 I hereby certify that this building, as designed, is in complianceFlorida Statutes. with the Florida Energy Code. {��WE, OWNER/AGENT:— BUILDING OFFICIAL: ATE _____ — _ __---_- _ --------_-.-- DATE: __._--_-- 2/11/2010 8:52 AM EnergyGauge®USA-FlaRes2008 Page 1 of 5