Loading...
Palmwood Lane 463 This plan approved subject to the following provisions being included in the building; In hollow mason v unit construction, each unit cell shall be reinforced with at least one No. 5 bar at all corners; poured and tamped with concrete,- such reinforcing shall be properly tied into the footing and spandrel beam. All wood truss rafters-- Loof constructinn shall be securely fastened to the exterior --- walls with approved hurricane anchors or clips. E22tjnaa shall be continuous monolithic concrete under exterior walls, reinforced with two 5/8" deformed reinforcing rods for one- story buildings and three 5/8" deformed reinfor- cing rods for two-story buildings. Reinforcing APP110VED rods shall be placed in the lower one-third of theCITY Of ATLAMFIC BEACH the footings, properly placed and fastened on BUILD;IN OFF CE U metal saddles with wire. Footings shall be 20" Date--_ wide and 8" thick minimum. o qo Pairnwc)o-j