Permit Mech 1719 Beach 2011 A r . ,f y
� ` � CITY OF ATLANTIC BEACH
: A ° ,, 800 SEMINOLE ROAD
J 1 - ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247 -5826
�. 9 f'
Application Number 11- 00001703 Date 2/22/11
Property Address 1719 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning TO BE UPDATED
Application valuation . . . 5100
Application desc
CHANGE OUT 3.5 TON SYSTEM
Owner Contractor
NAUGHTON, JAMES OCEAN STATE HEAT & AIR, INC.
1719 BEACH AVENUE #01 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 249 -8251
Permit MECHANICAL HVAC PERMIT
Additional desc . CHANGE OUT 3.5 TON SYSTEM
Permit Fee . . . 107.00 Plan Check Fee . . .00
Issue Date . . . Valuation . . . . 0
Expiration Date . 8/21/11
Other Fees STATE MECH DCA SURCHARGE 2.00
STATE MECH DBPR SURCHARGE 2.00
Fee summary Charged Paid Credited Due
Permit Fee Total 107.00 107.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 4.00 4.00 .00 .00
Grand Total 111.00 111.00 .00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION SL 1 lc/
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247 -5826 Fax (904) 247 -5845
JOB ADDRESS: / WI 3 ce c L Ave- PERMIT # / /—/ 70 3
PROJECT VALUE $ S i oo .UO
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI # GYY3 c c 7
Air Conditioning: Unit Quantity / Tons Per Unit .g. J REQUIRED
Heat: Unit Quantity / BTU's Per Unit to tow Seer Rating /3
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
- ` , Tanks (gallons)
.. C____ -- Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name TaLe,d-tc.-3 4- GlawAr, liclIt,-113K Phone Number LYt - QED3
Mechanical Company oc..40.t mac.. k`°'-ai"'`5 0«.e9 Air Office Phone zyF - sz.rl Fax 2 Y - 85'Yf
Co. Address: it/74, . - #40....xA. isi. I I .'>t &....c.(. City ,ci , e State Ft_ Zip 32-4 64
License Holder (Print): 6-1 . o.4--s , I State Cert lc. ■ ' egistration # c,¢L 6 �J 310
Notarized Signature of License Holder �'
,......... EiTe ................
......... -�+ oZ day of ��Dr 20
S orn and sub - 11 •re me thi
aa" r u Comm# 000860534 ��
Expires Si!. q ature of Notary P ,1 .lic , �� 1 � . �,
res 31?J2013
Florida Notary Assn., Inc
Ai :.1 CERTIFIED TM
www.ahridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 1443607 Date: 2/22/2011
Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source
Outdoor Unit Model Number: 4TWR3042A1
Indoor Unit Model Number: 4TEC3F42C1
Manufacturer: TRANE
Trade /Brand name: XR13 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240 -2006 for Unitary Air - Conditioning and Air- Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 40500
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 40500
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F: 26800
* Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which Indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(*) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed M the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificab shag only be used for Individual, personal and confidential reference purposes.
The contents of thls Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any
form or manner or by any means, except for the user's individual, personal and confidential reference.
CERTIFICATE VERIFICATION A
The Information for the model cited on this certificate can be verified at www.ahridirectory or Air Conditioning, Heating,
click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on riall .m � and Refrigeration Institute
which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed below.
02010 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129428575435182420