Loading...
1100 Sandpiper Ln WWTP#1DESIGN CRITEMA DESIGN PER 2007 FLORIDA BUILDING CODE WITH 2009 SUPPLEMENTS, UNLESS OTHERWISE NOTED. LIVE LOADS: STAIRS. 100 PSF GRATING 00 PSF CONCRETE (DESIGN PER CURRENT EDITION ACI 318) ALL CONCRETE ..... ..... ..... ... FC. 4000 PSI ALL REINFORCING STEEL ASN A615 GRADE 60. REWIFOtONG STEEL SHOWN ON MESE DRAWINGS TO BE WELDED SHALL BE ASTM A706. ALL WELDED WIRE FABRIC ASTM A85 GENERAL NOTES UNLESS OTHERWISE NOTED (LION) ON THE DRAWINGS, MINIUM COVER FOR REWORDING SHALL BE AS FOLLOWS FOOTNGS.......-..................... ........................ .... ......... ........ ............................................ 3" MATS ANO WALLS (EXPOSED TO EARN, LIQUID OR WEATHER) .............................. Z' SLABS AND WALLS (NOT EXPOSED TO EARN. UOUID OR MEANER) ..................... )L' ALL RENFORONG SMALL BE HELD SECURELY N POSITION NN STANDARD ACCESSORIES N CONFORMANCE NN CRS MANUAL OF STANDARD PRACTICE AND ACI 315 DURING THE PLACING OF THE CONCRETE. ALL HOOKS N REINFORCING BARS SHALL BE AN ACI STANDARD HOOK. UNLESS OTHERWISE NOTED. DOWELS FROM FOUNDATIONS OR SLABS TO WALLS SHALL MATO/ WALL REINFORCING, UNLESS OT ERWSE NOTED. DOWELS SHALL BE PLACED BEFORE CONCRETE IS POURED. THEY SHALL NOT BE PUSHED INTO THE CONCRETE. PROVIDE V CHAMFER AT ALL EXPOSED CORNERS OF BEAMS, WALL, ETC. ALL CONCRETE MIXES SHALL BE PROPORTIONED BY ME FIELD EXPERIENCE METHOD OR THE LABORATORY TRIAL MEMOD IN ACCORDANCE WAN ACI 318: MAXIMUM WATER/CEMENT RATIO SHALL BE 0.45. FDIIMDATIONS IF FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, UNSTABLE, OR UNSUITABLE SO.. THE ENGINEER SHALL BE NOTIFIED. STEPS IN WALL FOOTNOS SHALL NOT EXCEED A SLOPE O (1) VERTICAL TO TWO (2) HORIZONTAL. MINIMUM R I IN . & STAIRS HANDRAILS AND STAR RAILS SHALL BE DESIGNED TO WITHSTAND A 200/ CONCENTRATED LOAD APPLIED N ANY DIRECTION AT ANY PONT ON THE TOP RAL. HANDRAILS ANO STAIR RAILS SMALL ALSO BE DESIGNED TO WTHSTAND A LOAD O 50//FT APPLIED HORIZONTALLY TO THE TOPRAL. THE 200f LOAD WILL NOT BE APPLIED SIMULTANEOUSLY ON TE 50//FT LOAD. IN ADDITION, ME HANDRAILS SHALL BE DESIGNED TO WITHSTAND A LOAD OF 100#/FT APPLIED VERTICALLY DOWNWARD TO ME TOP RAL AND SIMULTANEOUSLY WITH THE 50i/FT HORIZONTAL LOAD. THE 100//FT VERTICAL LOAD DOES NOT APPLY TO STAIR RAILS. STAIRS SHALL BE DESIGED TO WITHSTAND THE LOADS DEFINED IN ME DESIGN CRITERIA. THE MANUFACTURER SHALL SUBMIT SIGNED AND SEALED CALCULATIONS AND SHOP DRAWINGS TO THE ENGNEER FOR APPROVAL. POST SPACING SMALL BE A MAXIMUM O B' -O POSTS ANO RAILINGS SHALL BE A "NUM OF UI` SCHEDULE 40 ALUMINUM PIPE ALLOY 8108-T5. ASTM -B-429 OR ASTM -8-231. ME HANDRAIL 94ALL BE MADE O PIPES JOINED TOGETHER WIN COMPONENT FITTINGS. COMPONENTS THAT ARE POP -RIVETED DR GLUED AT ME JOINTS WILL NOT BE ACCEPTABLE. ALL COMPONENTS MUST BE MECHANICALLY FASTENED WITH STAINLESS STEEL HARDWARE. HANDRAIL AND COMPONENTS SHALL BE AS MANUFACTURED BY THOMPSON FABRICATING COMPANY (BIRMINGHAM, ALABAMA) OR APPROVED EQUAL. POSTS SHALL NOT INTERRUPT THE CONTINUATION O THE TOP RAIL AT ANY PONT ALONG ME RALIING. INCLUDING CORNERS AND END TERMINATIONS. ME TOP SURFACE O THE TOP RAILING SHALL BE SMOOTH AND SHALL NOT BE NTERRUPTED BY PROJECTED FITTINGS. ME NDIRAL AT A CORNER RETURN SHALL BE ABLE TO WITHSTAND A 200/ LOAD WITHOUT LOOSENING. THE MANUFACTURER IS TO DETERMINE THIS DIMENSION FOR THEIR SYSTEM. PROVIDE PHYSICAL TESTS FROM A LABORATORY TO CONFIRM COMPLIANCE. EXPANSION BOTS SMALL BE SPACED IOW APART AND 5• EDGE DISTANCE FOR NO REDUCTION IN PULLOUT STRENGTH, A SAFETY FACTOR OF "4"- SHALL GE USED ON EXPANSION BOT PULLOUT VALUES PUBLISHED BY THE MANUFACTURER. EXPANSION BOLTS SHALL BE STAINLESS STEEL TYPE 18-8 WEDGE BOLTS AND SHALL BE FURNISHED BY THE HANDRAIL MANUFACTURER. TOE PLATE SHALL BE A MINIMUM OF 4' MGH AND SHALL BE AN EXTRUSION NAT ATTACHES TO ME POSTS WTH CLAMPS WINCH WILL ALLOW FOR EXPANSION AND CONTRACTION BETWEEN POSTS. TOE PLATES SMALL BE SET (" ABOVE THE WALXNG SURFACE. FINISH SHALL BE ALUMINUM ASSOCIATION M10 -C22-441 (215-R1). THE PIPE SMALL BE PLASTIC -WRAPPED. ME PLASTIC WRAP IS TO BE REMOVED AFTER ERECTION. ALUMINUM SURFACES IN CONTACT WITH CONCRETE. GROUT OR DISSIMILAR METALS WILL BE PROTECTED WIN A COAT OF BITUMINOUS PAINT, HYLAR ISOLATORS OR OTHER APPROVED MATERIAL. ALUMINUM GRATING GRATING SHALL BE FABRICATED OF ALUMINUM I -SHAPED BARS. ALLOY 6063-T6, WITH SWAGED CROSS BARS SPACED ON 4' CENTERS 13EAMNC BARS SHALL BE SPACED ON l I." CENTERS. TOP SURFACE OF BEARNG BARS SHALL BE STRIATED TO PROIOE A NONSUP SURFACE. PLANKING 91A1. BE EXTRUDED FROM ALUMINUM ALLOY 6063-T6. TOP SURFACE SMALL BE PUNCHED (NN UPSET EDGES) OR ND UNPUNCHED, AS SPECIFIED ON THE PLANS, A SHALL HAVE CONTINUOUS STRIATIONS FOR SKID RESISTANCE. STANDARD NSTMLATION CLEARANCES AND TOLERANCES SHALL CONFORM TO THE REDUREMENTS OF ME CURRENT METAL BAR GRATING MANUAL PUBLISHED BY THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS INSTALL ALUMINUM CLAMPS OR CUPS TO ANCHOR GRATING AND PLANKING TO SUPPORTS A MINIUM O FOUR FASTENERS IS REQUIRED PER PANEL UNLESS OTHERWISE NOTED ON THE DRAWINGS CLIPS SMALL NOT PROTRUDE ABOVE THE TOP OF THE GRATING. CUTOUTS FOR CIRCULAR OBSTRUCTIONS TO BE AT LEAST 2' LARGER IN DIAMETER MAN THE OBSTRUCTION. CUTOUTS FOR ALL P1P1NG 4' AND LESS IN DIAMETER TO BE MADE IN THE FIELD. ALL OPENINGS WHERE MORE THAN FOUR BEARNG BARS ARE CUT SHALL BE BANDED NM BAR THE SAME DEPTH AS ME BEARING BARS. THE ENDS OF ALL GRATING AND PLANKING PANELS SHALL BE BANDED. SHELF ANGLES SHALL BE ANCHORED TO CONCRETE WITH TYPE 18-8 STAINLESS STEEL WEDGE ANCHORS ALUMINUM STAR TREADS SHALL BE I -BAR GRATING TYPE TREADS AND SHALL BE I MI FL S14ED WITH EXTRUDED ALUMINUM CORRUGATED NOSING. ALUMINUM CARRIER ANGLES SHALL BE MELDED TO ME ENDS O STAR MEADS MINIMUM DEPTH O GRATING AT TREADS SHALL BE to". ALUMINUM SURFACES IN CONTACT NTH CONCRETE OR DISSIMILAR METALS SHALL BE PROTECTED WITH A COAT O 8111UMIIOUS PANT. aWPI NT PY NO � PROVIDE ALL TEMPORARY BRACING. SHORING, GUYING OR OTHER MEANS TO AVOID EXCESS A STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. THE STRUCTURE SHOULD NOT BE CONSIDERED STABLE UNTIL ALL STRUCTURAL ELEMENTS HAVE BEEN CONSTRUCTED IN ACCORDANCE WN THE CONTRACT DOCUMENTS. MCVEIGH & MANGUM ENGINEERING. INC OR ANY OF ITS EMPLOYEES SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES OR SEQUENCES FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING ME WORK, OR FOR THE FAILURE OF ANY OF THEY TO CARRY OUT THE WORK N ACCORDANCE WITH THE CONTRACT DOCUMENTS, VERIFY ALL DIMENSIONS NTH MECHANICAL ORAWNGS. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES. ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL AND PLUMBING EOUIPMENT SHALL BE VERIFIED NTH EOUPMENT PURCHASED BEFORE PROCEEDING WN STRUCTURAL WORK AFFECTED. CONTRACTOR SMALL VERIFY ALL EXISTNG DIMENSIONS AND CONDITIONS OF EXISTING STRUCTURE AND SITES THAT ARE AFFECTED BY NEW WORK BEFORE PROCEEDING NM FABRICATION AND CONSTRUCTION. EMBEDMENT FOR EXPANSION BOLTS SHALL BE 44" MINIMUM FOR %"* BOLTS IN CONCRETE OR GROUTED MASONRY. MITI KW BOLT 3 OR EQUAL EPDXY GROUT SHALL BE HnSO CARTRIDGE SYSTEM BY HILT: (MILT[ RE500, IF HOLE IS CORED INSTEAD OF DRILLED) OR APPROVED EOUAL. LION. EMBEDMENT SHALL BE 12 BAR DIAMETER MINIMUM, UON. HOLES SHALL BE A" LARGER MAN REBAR 92E AND IL" LARGER NAN THREADED ROD SIZE. HOLE SHALL BE BRUSHED OUT WITH BOTTLE BRUSH AND MEN BLOWN OUT NTH MR USING A COMPRESSOR NTH A FUNCTIONAL OIL TRAP. INSTALLATION SMALL BE IN ACCORDANCE NTH MANUFACTURERS PRINTED INSTRUCTIONS. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SMALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT. GENERAL CONTRACTOR MUST RENEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO ENGINEER. SUBMITTALS WHICH 00 NOT CONTAIN THE CONTRACTOR'S SHOP DRAWING STAMP OR HAVE BEEN MERELY *RUBBER STAMPED" SHALL BE RETURNED WTHOUT REVIEW. CHANGES TO ME CONTRACT DOCUMENTS SHALL BE CLOUDED ON 940P DRAWINGS OR REQUESTED IN WRITING. THE CONTRACTOR IS LIABLE FOR ANY DEVIATIONS UNLESS REVIEWED AND ACKNOWLEDGED BY THE ENGINEER. SHOP DRAWING SUBMITTALS SHALL ONLY BE CHECKED FOR CONFORMANCE NTH THE DESIGN CONCEPT AND THE INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS. HYDROSTATIC TESTING OF [OIG ETE TANKS WELLS & CHANNELS IT IS THE INTENT THAT ALL TANKS, FELLS. & CHANNELS DESIGNED TO HOLD OR CONVEY SEWAGE OR DERIVATIVES THEREOF, WILL DO SO WTHOU7 LEAKS OR WEEPS. PRIOR TO INTRODUCTION OF SEWAGE & AS A CONDITION OF SUBSTANTIAL COMPLETION, ALL CONCRETE TANKS. WELLS AND CHANNELS SHALL BE INDIVIDUALLY HYDROSTATICALLY TESTED FOR GROUNDWATER INFILTRATION, WHERE APPUCABLE & EXFILTRATION, ALL CONCRETE WALLS, COVERS, & BOTTOMS SHALL BE SUBJECTED TO VISUAL INSPECTION FOR HYDROSTATIC LEAKAGE AS WELL AS OTHER FAULTS OR DEFECTS, & ANY LEAKAGE OR OTHER M98LE DEFECT SHALL BE CORRECTED O ONCE. INVESTIGATION & REPAIR OF LEAKS & WEEPS SMALL BE PERFORMED AFTER COMPLETION OF PREPARATION AND PAINTING OF SURFACES SUBMERGED BY SEWAGE OR DERIVATIVES THEREOF. HOWEVER, TESTING & REPAIR SHALL BE CONDUCTED PRIOR TO THE APPLICATION OF CEMENTITIOUS COATING SPECIFIED. IN ANY EVENT, LEAKS & WEEPS WHICH ARE EVIDENCED PRIOR TO, DURING. OR AFTER PREPARATION & PANTING OPERATIONS SHALL BE REPAIRED IMMEDIATELY, & PRIOR TO, CONTINUING SUCH OPERATIONS. ALL HYDROSTATIC TESTING SHALL BE PERFORMED BY THE CONTRACTOR WHO SHALL PROVIDE ALL NECESSARY EOUIPMENT & MONITORING SERVICES REQUIRED. THE CONTRACTOR SHALL MAKE ARRANGEMENTS FOR & PAY ALL COSTS O WATER REOURED TESTING. WATER RESOURCES CONSIDERED ACCEPTABLE ARE: THE CITY/COUNTY WATER SUPPLY: TREATED PLANT EFFLUENT, IF AVAILABLE; & GROUNDWATER, IF THE PLANT EFFLUENT IS USED, IT LUST BE CHLORINATED PRIOR TO SPENT WATER DISCHARGE INTO THE REGULAR RECEIVING WATERS. ALL SURFACES PANTED OR LINPANTED. WHICH WILL NOT REMAIN SUBMERGED AFTER TESTING, & WHICH WERE COVERED OR SPLASHED WITH PLANT EFFLUENT WATER DURING TESTING, MUST BE SCRUBBED AFTER TESTING, IN ORDER TO PREVENT _ DEVELOPMENT O DOOR, IF GROUNDWATER USED. IT MAY BE NECESSARY TO SCRUB NESE SAME CONCRETE SURFACES COVERED OR SPLASHED BY IT TO REMOVE STAIN. IT MAY ALSO BE NECESSARY TO CHLORINATE GROUNDWATER USED FOR TESTING PRIOR TO DISCHARGE INTO THE REGULAR RECEIVING WATERS. VISIBLE INFILTRATION. SUCH AS THAT SEEPING THROUGH SHRINKAGE CRACKS. SHALL BE ALLOWED A PERIOD OF ONE WEEK TO "HEAL". IF INFILTRATION DOES NOT CEASE, THE CONTRACTOR SHALL TAKE WHATEVER STEPS NECESSARY TO REPAIR THE LEA( OR WEEP, AS WELL AS ANY OTHER GROUND WATER INFILTRATION THAT MAY BE APPARENT TO THE SATISFACTION OF THE ENGINEER. CONCRETE TANKS, WETWELLS, & CHANNELS SHALL BE INDIVIDUALLY FILLED NTH WATER SOURCES AS DEFINED ABOVE TO ME MAXIMUM DESIGN OPERATION LEVEL O EACH UNIT & MAINTAINED AT THIS ELEVATION FOR A PERIOD O ONE WEEK. THE TERM "INDIVIDUALLY FILLED', ALLOWS NON -ADJACENT TANKS, WETWELLS, & CHANNELS TO BE FILLED, NUS PERMITTING THE CHECKING FOR LEAKAGES INTO THE ADJACENT STRUCTURE. THE TESTING OF WATER TIGHTNESS SHALL BE IN ACCORDANCE WITH A0350.1. VISIBLE LEAKAGE OR WEEPS THAT DO NOT CEASE WITHIN A WEEK, MUST BE REPAIRED BY ME CONTRACTOR TO THE SATISFACTION O ME ENGINEER. UNDERGROUND LEAKAGE EVIDENCED BY DEVELOPMENT OF WET AREAS AROUND ME PERIPHERY OF THE STRUCTURES, MUST BE INVESTIGATED BY ME CONTRACTOR & THE SOURCE OF THE LEAKAGE REPAIRED. ANY TANK STRUCTURE. WHICH INDICATES A LOSS OF WATER, IN ACCESS OF OJX OF THE WATERVOLUME IN A 24 HOUR PERIOD MUST BE INVESTIGATED By THE CONTRACTOR FOR LEAKAGE & WATER POSSIBLY RETAINED IN SAID STRUCTURE FOR A PERIOD OF 2 TO 3 WEEKS IN CONTRACTOR'S EFFORT TO LOCATE LEAKAGE It MAKE ALL NECESSARY REPAIRS UPON THE SUCCESSFUL COMPLETION OF TME ABOVE DEFINED HYDROSTATIC TESTING. ME TEST WATER SHALL REMAIN IN THE VARIOUS STRUCTURES AT MAXIMUM OPERATING LEVELS PRESCRIBED ON ME CONTRACT DRAWINGS FOR THE PERFORMANCE O OTHER TESTING & ADJUSTMENTS SET FORTH IN THESE SPECIFICATIONS, UNTIL ISSUANCE OF SUBSTANTIAL COMPLETION FOR THE ENTIRE FACILITY. THE CONTRACTOR SHALL PROVIDE MAKE-UP WATER REQUIRED TO MAINTAIN THESE PRESCRIBED OPERATING LEVELS. UPON ISSUANCE OF SUBSTANTIAL COMPLETION. THE FACILITY WILL BE PLACED IN OPERATION & TEST WATER DISPLACED WITH SEWAGE & DERIVATIVES THEREOF. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE CHLORINATION AS RECURRED TO THE CONTROL GROWN O ALGAE & DEVELOPMENT OF ODOR DURNG THE CONTAINMENT OF TEST WATER, PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR CHLORINATION & CHLORINE CONTENT O ANY TEST WATER DISCHARGED PRIOR TO SUBSTANTIAL COMPLETION. BUT NOT AFTERWARDS. CONCRETE WORK SHALL CONFORM TO THE REQyIP�i(FjN� BEACH CONCRETE "SPECIFICATIONS FOR STRUCTURAL CONCRETE E RI BUIL C(�TLJOI EXCEPT AS MODIFIED BY ME REQUIREMENTS OF THE PING OFFICE FEB O l 2111 // } /11 By: iFv\,N. 0 1 •••••M••••, ��aYoo GEN % • • 1 • No. 52 ° R. ° • ro S" OF s'�t, Ad�IA •0a• � d 0•a i 0 W®moi Ve�` g(•yWg�o� �`a''j+, ,�4� &At MCVEIGH & MANGUM t. ENGINEERING•INC 9133 R.6. $Almlaf Parkway 483 5lle, PlwiEa 3223fi PL: (901)483-52(q Pax: (904)6366]]0 Tie 6330 wail: mul®Mcve��t.HauW�an.com PnW. oreaaa: rim w. oa® Lam.. Ha.: stns DESIGN CRITERIA do GENERAL NOTES ISSUED FOR BIDS 11/4/2010 ADDENDUM /2 11/17/2010 NO W Z Q J CL O J 0 cz O LLR L.L. 0 Z � W :5 - Lu O CL P. 'FF CL H 3 0 i A1° SEPTEMBER 2010 CALF AS SHOWN RAWN BY RMF ESIGNED BY TWO HEET SO.1 46 OF 72 SHEETS STRUCTURAL ABBREVIATIONS / NUMBER OR POUND EXT EXTERIOR x r' DESIGN CRITEMA DESIGN PER 2007 FLORIDA BUILDING CODE WITH 2009 SUPPLEMENTS, UNLESS OTHERWISE NOTED. LIVE LOADS: STAIRS. 100 PSF GRATING 00 PSF CONCRETE (DESIGN PER CURRENT EDITION ACI 318) ALL CONCRETE ..... ..... ..... ... FC. 4000 PSI ALL REINFORCING STEEL ASN A615 GRADE 60. REWIFOtONG STEEL SHOWN ON MESE DRAWINGS TO BE WELDED SHALL BE ASTM A706. ALL WELDED WIRE FABRIC ASTM A85 GENERAL NOTES UNLESS OTHERWISE NOTED (LION) ON THE DRAWINGS, MINIUM COVER FOR REWORDING SHALL BE AS FOLLOWS FOOTNGS.......-..................... ........................ .... ......... ........ ............................................ 3" MATS ANO WALLS (EXPOSED TO EARN, LIQUID OR WEATHER) .............................. Z' SLABS AND WALLS (NOT EXPOSED TO EARN. UOUID OR MEANER) ..................... )L' ALL RENFORONG SMALL BE HELD SECURELY N POSITION NN STANDARD ACCESSORIES N CONFORMANCE NN CRS MANUAL OF STANDARD PRACTICE AND ACI 315 DURING THE PLACING OF THE CONCRETE. ALL HOOKS N REINFORCING BARS SHALL BE AN ACI STANDARD HOOK. UNLESS OTHERWISE NOTED. DOWELS FROM FOUNDATIONS OR SLABS TO WALLS SHALL MATO/ WALL REINFORCING, UNLESS OT ERWSE NOTED. DOWELS SHALL BE PLACED BEFORE CONCRETE IS POURED. THEY SHALL NOT BE PUSHED INTO THE CONCRETE. PROVIDE V CHAMFER AT ALL EXPOSED CORNERS OF BEAMS, WALL, ETC. ALL CONCRETE MIXES SHALL BE PROPORTIONED BY ME FIELD EXPERIENCE METHOD OR THE LABORATORY TRIAL MEMOD IN ACCORDANCE WAN ACI 318: MAXIMUM WATER/CEMENT RATIO SHALL BE 0.45. FDIIMDATIONS IF FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, UNSTABLE, OR UNSUITABLE SO.. THE ENGINEER SHALL BE NOTIFIED. STEPS IN WALL FOOTNOS SHALL NOT EXCEED A SLOPE O (1) VERTICAL TO TWO (2) HORIZONTAL. MINIMUM R I IN . & STAIRS HANDRAILS AND STAR RAILS SHALL BE DESIGNED TO WITHSTAND A 200/ CONCENTRATED LOAD APPLIED N ANY DIRECTION AT ANY PONT ON THE TOP RAL. HANDRAILS ANO STAIR RAILS SMALL ALSO BE DESIGNED TO WTHSTAND A LOAD O 50//FT APPLIED HORIZONTALLY TO THE TOPRAL. THE 200f LOAD WILL NOT BE APPLIED SIMULTANEOUSLY ON TE 50//FT LOAD. IN ADDITION, ME HANDRAILS SHALL BE DESIGNED TO WITHSTAND A LOAD OF 100#/FT APPLIED VERTICALLY DOWNWARD TO ME TOP RAL AND SIMULTANEOUSLY WITH THE 50i/FT HORIZONTAL LOAD. THE 100//FT VERTICAL LOAD DOES NOT APPLY TO STAIR RAILS. STAIRS SHALL BE DESIGED TO WITHSTAND THE LOADS DEFINED IN ME DESIGN CRITERIA. THE MANUFACTURER SHALL SUBMIT SIGNED AND SEALED CALCULATIONS AND SHOP DRAWINGS TO THE ENGNEER FOR APPROVAL. POST SPACING SMALL BE A MAXIMUM O B' -O POSTS ANO RAILINGS SHALL BE A "NUM OF UI` SCHEDULE 40 ALUMINUM PIPE ALLOY 8108-T5. ASTM -B-429 OR ASTM -8-231. ME HANDRAIL 94ALL BE MADE O PIPES JOINED TOGETHER WIN COMPONENT FITTINGS. COMPONENTS THAT ARE POP -RIVETED DR GLUED AT ME JOINTS WILL NOT BE ACCEPTABLE. ALL COMPONENTS MUST BE MECHANICALLY FASTENED WITH STAINLESS STEEL HARDWARE. HANDRAIL AND COMPONENTS SHALL BE AS MANUFACTURED BY THOMPSON FABRICATING COMPANY (BIRMINGHAM, ALABAMA) OR APPROVED EQUAL. POSTS SHALL NOT INTERRUPT THE CONTINUATION O THE TOP RAIL AT ANY PONT ALONG ME RALIING. INCLUDING CORNERS AND END TERMINATIONS. ME TOP SURFACE O THE TOP RAILING SHALL BE SMOOTH AND SHALL NOT BE NTERRUPTED BY PROJECTED FITTINGS. ME NDIRAL AT A CORNER RETURN SHALL BE ABLE TO WITHSTAND A 200/ LOAD WITHOUT LOOSENING. THE MANUFACTURER IS TO DETERMINE THIS DIMENSION FOR THEIR SYSTEM. PROVIDE PHYSICAL TESTS FROM A LABORATORY TO CONFIRM COMPLIANCE. EXPANSION BOTS SMALL BE SPACED IOW APART AND 5• EDGE DISTANCE FOR NO REDUCTION IN PULLOUT STRENGTH, A SAFETY FACTOR OF "4"- SHALL GE USED ON EXPANSION BOT PULLOUT VALUES PUBLISHED BY THE MANUFACTURER. EXPANSION BOLTS SHALL BE STAINLESS STEEL TYPE 18-8 WEDGE BOLTS AND SHALL BE FURNISHED BY THE HANDRAIL MANUFACTURER. TOE PLATE SHALL BE A MINIMUM OF 4' MGH AND SHALL BE AN EXTRUSION NAT ATTACHES TO ME POSTS WTH CLAMPS WINCH WILL ALLOW FOR EXPANSION AND CONTRACTION BETWEEN POSTS. TOE PLATES SMALL BE SET (" ABOVE THE WALXNG SURFACE. FINISH SHALL BE ALUMINUM ASSOCIATION M10 -C22-441 (215-R1). THE PIPE SMALL BE PLASTIC -WRAPPED. ME PLASTIC WRAP IS TO BE REMOVED AFTER ERECTION. ALUMINUM SURFACES IN CONTACT WITH CONCRETE. GROUT OR DISSIMILAR METALS WILL BE PROTECTED WIN A COAT OF BITUMINOUS PAINT, HYLAR ISOLATORS OR OTHER APPROVED MATERIAL. ALUMINUM GRATING GRATING SHALL BE FABRICATED OF ALUMINUM I -SHAPED BARS. ALLOY 6063-T6, WITH SWAGED CROSS BARS SPACED ON 4' CENTERS 13EAMNC BARS SHALL BE SPACED ON l I." CENTERS. TOP SURFACE OF BEARNG BARS SHALL BE STRIATED TO PROIOE A NONSUP SURFACE. PLANKING 91A1. BE EXTRUDED FROM ALUMINUM ALLOY 6063-T6. TOP SURFACE SMALL BE PUNCHED (NN UPSET EDGES) OR ND UNPUNCHED, AS SPECIFIED ON THE PLANS, A SHALL HAVE CONTINUOUS STRIATIONS FOR SKID RESISTANCE. STANDARD NSTMLATION CLEARANCES AND TOLERANCES SHALL CONFORM TO THE REDUREMENTS OF ME CURRENT METAL BAR GRATING MANUAL PUBLISHED BY THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS INSTALL ALUMINUM CLAMPS OR CUPS TO ANCHOR GRATING AND PLANKING TO SUPPORTS A MINIUM O FOUR FASTENERS IS REQUIRED PER PANEL UNLESS OTHERWISE NOTED ON THE DRAWINGS CLIPS SMALL NOT PROTRUDE ABOVE THE TOP OF THE GRATING. CUTOUTS FOR CIRCULAR OBSTRUCTIONS TO BE AT LEAST 2' LARGER IN DIAMETER MAN THE OBSTRUCTION. CUTOUTS FOR ALL P1P1NG 4' AND LESS IN DIAMETER TO BE MADE IN THE FIELD. ALL OPENINGS WHERE MORE THAN FOUR BEARNG BARS ARE CUT SHALL BE BANDED NM BAR THE SAME DEPTH AS ME BEARING BARS. THE ENDS OF ALL GRATING AND PLANKING PANELS SHALL BE BANDED. SHELF ANGLES SHALL BE ANCHORED TO CONCRETE WITH TYPE 18-8 STAINLESS STEEL WEDGE ANCHORS ALUMINUM STAR TREADS SHALL BE I -BAR GRATING TYPE TREADS AND SHALL BE I MI FL S14ED WITH EXTRUDED ALUMINUM CORRUGATED NOSING. ALUMINUM CARRIER ANGLES SHALL BE MELDED TO ME ENDS O STAR MEADS MINIMUM DEPTH O GRATING AT TREADS SHALL BE to". ALUMINUM SURFACES IN CONTACT NTH CONCRETE OR DISSIMILAR METALS SHALL BE PROTECTED WITH A COAT O 8111UMIIOUS PANT. aWPI NT PY NO � PROVIDE ALL TEMPORARY BRACING. SHORING, GUYING OR OTHER MEANS TO AVOID EXCESS A STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. THE STRUCTURE SHOULD NOT BE CONSIDERED STABLE UNTIL ALL STRUCTURAL ELEMENTS HAVE BEEN CONSTRUCTED IN ACCORDANCE WN THE CONTRACT DOCUMENTS. MCVEIGH & MANGUM ENGINEERING. INC OR ANY OF ITS EMPLOYEES SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES OR SEQUENCES FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING ME WORK, OR FOR THE FAILURE OF ANY OF THEY TO CARRY OUT THE WORK N ACCORDANCE WITH THE CONTRACT DOCUMENTS, VERIFY ALL DIMENSIONS NTH MECHANICAL ORAWNGS. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES. ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL AND PLUMBING EOUIPMENT SHALL BE VERIFIED NTH EOUPMENT PURCHASED BEFORE PROCEEDING WN STRUCTURAL WORK AFFECTED. CONTRACTOR SMALL VERIFY ALL EXISTNG DIMENSIONS AND CONDITIONS OF EXISTING STRUCTURE AND SITES THAT ARE AFFECTED BY NEW WORK BEFORE PROCEEDING NM FABRICATION AND CONSTRUCTION. EMBEDMENT FOR EXPANSION BOLTS SHALL BE 44" MINIMUM FOR %"* BOLTS IN CONCRETE OR GROUTED MASONRY. MITI KW BOLT 3 OR EQUAL EPDXY GROUT SHALL BE HnSO CARTRIDGE SYSTEM BY HILT: (MILT[ RE500, IF HOLE IS CORED INSTEAD OF DRILLED) OR APPROVED EOUAL. LION. EMBEDMENT SHALL BE 12 BAR DIAMETER MINIMUM, UON. HOLES SHALL BE A" LARGER MAN REBAR 92E AND IL" LARGER NAN THREADED ROD SIZE. HOLE SHALL BE BRUSHED OUT WITH BOTTLE BRUSH AND MEN BLOWN OUT NTH MR USING A COMPRESSOR NTH A FUNCTIONAL OIL TRAP. INSTALLATION SMALL BE IN ACCORDANCE NTH MANUFACTURERS PRINTED INSTRUCTIONS. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SMALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT. GENERAL CONTRACTOR MUST RENEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO ENGINEER. SUBMITTALS WHICH 00 NOT CONTAIN THE CONTRACTOR'S SHOP DRAWING STAMP OR HAVE BEEN MERELY *RUBBER STAMPED" SHALL BE RETURNED WTHOUT REVIEW. CHANGES TO ME CONTRACT DOCUMENTS SHALL BE CLOUDED ON 940P DRAWINGS OR REQUESTED IN WRITING. THE CONTRACTOR IS LIABLE FOR ANY DEVIATIONS UNLESS REVIEWED AND ACKNOWLEDGED BY THE ENGINEER. SHOP DRAWING SUBMITTALS SHALL ONLY BE CHECKED FOR CONFORMANCE NTH THE DESIGN CONCEPT AND THE INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS. HYDROSTATIC TESTING OF [OIG ETE TANKS WELLS & CHANNELS IT IS THE INTENT THAT ALL TANKS, FELLS. & CHANNELS DESIGNED TO HOLD OR CONVEY SEWAGE OR DERIVATIVES THEREOF, WILL DO SO WTHOU7 LEAKS OR WEEPS. PRIOR TO INTRODUCTION OF SEWAGE & AS A CONDITION OF SUBSTANTIAL COMPLETION, ALL CONCRETE TANKS. WELLS AND CHANNELS SHALL BE INDIVIDUALLY HYDROSTATICALLY TESTED FOR GROUNDWATER INFILTRATION, WHERE APPUCABLE & EXFILTRATION, ALL CONCRETE WALLS, COVERS, & BOTTOMS SHALL BE SUBJECTED TO VISUAL INSPECTION FOR HYDROSTATIC LEAKAGE AS WELL AS OTHER FAULTS OR DEFECTS, & ANY LEAKAGE OR OTHER M98LE DEFECT SHALL BE CORRECTED O ONCE. INVESTIGATION & REPAIR OF LEAKS & WEEPS SMALL BE PERFORMED AFTER COMPLETION OF PREPARATION AND PAINTING OF SURFACES SUBMERGED BY SEWAGE OR DERIVATIVES THEREOF. HOWEVER, TESTING & REPAIR SHALL BE CONDUCTED PRIOR TO THE APPLICATION OF CEMENTITIOUS COATING SPECIFIED. IN ANY EVENT, LEAKS & WEEPS WHICH ARE EVIDENCED PRIOR TO, DURING. OR AFTER PREPARATION & PANTING OPERATIONS SHALL BE REPAIRED IMMEDIATELY, & PRIOR TO, CONTINUING SUCH OPERATIONS. ALL HYDROSTATIC TESTING SHALL BE PERFORMED BY THE CONTRACTOR WHO SHALL PROVIDE ALL NECESSARY EOUIPMENT & MONITORING SERVICES REQUIRED. THE CONTRACTOR SHALL MAKE ARRANGEMENTS FOR & PAY ALL COSTS O WATER REOURED TESTING. WATER RESOURCES CONSIDERED ACCEPTABLE ARE: THE CITY/COUNTY WATER SUPPLY: TREATED PLANT EFFLUENT, IF AVAILABLE; & GROUNDWATER, IF THE PLANT EFFLUENT IS USED, IT LUST BE CHLORINATED PRIOR TO SPENT WATER DISCHARGE INTO THE REGULAR RECEIVING WATERS. ALL SURFACES PANTED OR LINPANTED. WHICH WILL NOT REMAIN SUBMERGED AFTER TESTING, & WHICH WERE COVERED OR SPLASHED WITH PLANT EFFLUENT WATER DURING TESTING, MUST BE SCRUBBED AFTER TESTING, IN ORDER TO PREVENT _ DEVELOPMENT O DOOR, IF GROUNDWATER USED. IT MAY BE NECESSARY TO SCRUB NESE SAME CONCRETE SURFACES COVERED OR SPLASHED BY IT TO REMOVE STAIN. IT MAY ALSO BE NECESSARY TO CHLORINATE GROUNDWATER USED FOR TESTING PRIOR TO DISCHARGE INTO THE REGULAR RECEIVING WATERS. VISIBLE INFILTRATION. SUCH AS THAT SEEPING THROUGH SHRINKAGE CRACKS. SHALL BE ALLOWED A PERIOD OF ONE WEEK TO "HEAL". IF INFILTRATION DOES NOT CEASE, THE CONTRACTOR SHALL TAKE WHATEVER STEPS NECESSARY TO REPAIR THE LEA( OR WEEP, AS WELL AS ANY OTHER GROUND WATER INFILTRATION THAT MAY BE APPARENT TO THE SATISFACTION OF THE ENGINEER. CONCRETE TANKS, WETWELLS, & CHANNELS SHALL BE INDIVIDUALLY FILLED NTH WATER SOURCES AS DEFINED ABOVE TO ME MAXIMUM DESIGN OPERATION LEVEL O EACH UNIT & MAINTAINED AT THIS ELEVATION FOR A PERIOD O ONE WEEK. THE TERM "INDIVIDUALLY FILLED', ALLOWS NON -ADJACENT TANKS, WETWELLS, & CHANNELS TO BE FILLED, NUS PERMITTING THE CHECKING FOR LEAKAGES INTO THE ADJACENT STRUCTURE. THE TESTING OF WATER TIGHTNESS SHALL BE IN ACCORDANCE WITH A0350.1. VISIBLE LEAKAGE OR WEEPS THAT DO NOT CEASE WITHIN A WEEK, MUST BE REPAIRED BY ME CONTRACTOR TO THE SATISFACTION O ME ENGINEER. UNDERGROUND LEAKAGE EVIDENCED BY DEVELOPMENT OF WET AREAS AROUND ME PERIPHERY OF THE STRUCTURES, MUST BE INVESTIGATED BY ME CONTRACTOR & THE SOURCE OF THE LEAKAGE REPAIRED. ANY TANK STRUCTURE. WHICH INDICATES A LOSS OF WATER, IN ACCESS OF OJX OF THE WATERVOLUME IN A 24 HOUR PERIOD MUST BE INVESTIGATED By THE CONTRACTOR FOR LEAKAGE & WATER POSSIBLY RETAINED IN SAID STRUCTURE FOR A PERIOD OF 2 TO 3 WEEKS IN CONTRACTOR'S EFFORT TO LOCATE LEAKAGE It MAKE ALL NECESSARY REPAIRS UPON THE SUCCESSFUL COMPLETION OF TME ABOVE DEFINED HYDROSTATIC TESTING. ME TEST WATER SHALL REMAIN IN THE VARIOUS STRUCTURES AT MAXIMUM OPERATING LEVELS PRESCRIBED ON ME CONTRACT DRAWINGS FOR THE PERFORMANCE O OTHER TESTING & ADJUSTMENTS SET FORTH IN THESE SPECIFICATIONS, UNTIL ISSUANCE OF SUBSTANTIAL COMPLETION FOR THE ENTIRE FACILITY. THE CONTRACTOR SHALL PROVIDE MAKE-UP WATER REQUIRED TO MAINTAIN THESE PRESCRIBED OPERATING LEVELS. UPON ISSUANCE OF SUBSTANTIAL COMPLETION. THE FACILITY WILL BE PLACED IN OPERATION & TEST WATER DISPLACED WITH SEWAGE & DERIVATIVES THEREOF. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE CHLORINATION AS RECURRED TO THE CONTROL GROWN O ALGAE & DEVELOPMENT OF ODOR DURNG THE CONTAINMENT OF TEST WATER, PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR CHLORINATION & CHLORINE CONTENT O ANY TEST WATER DISCHARGED PRIOR TO SUBSTANTIAL COMPLETION. BUT NOT AFTERWARDS. CONCRETE WORK SHALL CONFORM TO THE REQyIP�i(FjN� BEACH CONCRETE "SPECIFICATIONS FOR STRUCTURAL CONCRETE E RI BUIL C(�TLJOI EXCEPT AS MODIFIED BY ME REQUIREMENTS OF THE PING OFFICE FEB O l 2111 // } /11 By: iFv\,N. 0 1 •••••M••••, ��aYoo GEN % • • 1 • No. 52 ° R. ° • ro S" OF s'�t, Ad�IA •0a• � d 0•a i 0 W®moi Ve�` g(•yWg�o� �`a''j+, ,�4� &At MCVEIGH & MANGUM t. ENGINEERING•INC 9133 R.6. $Almlaf Parkway 483 5lle, PlwiEa 3223fi PL: (901)483-52(q Pax: (904)6366]]0 Tie 6330 wail: mul®Mcve��t.HauW�an.com PnW. oreaaa: rim w. oa® Lam.. Ha.: stns DESIGN CRITERIA do GENERAL NOTES ISSUED FOR BIDS 11/4/2010 ADDENDUM /2 11/17/2010 NO W Z Q J CL O J 0 cz O LLR L.L. 0 Z � W :5 - Lu O CL P. 'FF CL H 3 0 i A1° SEPTEMBER 2010 CALF AS SHOWN RAWN BY RMF ESIGNED BY TWO HEET SO.1 46 OF 72 SHEETS STRUCTURAL ABBREVIATIONS / NUMBER OR POUND EXT EXTERIOR R OR RAD RADIUS e ROUND OR DIAMETER EW EACH WAY RD ROUND v SQUARE FB FLAT BAR REF REFERENCE & AND FD FLOOR DRAIN REINF REINFORCE(MENT) OAT FDN FOUNDATION RED REQUIRE ALUM ALUMINUM FF FINISH FLOOR REDID REQUIRED AR ANCHOR ROD FUR FLOOR RET RETAINING ARCH ARCHITECTURE FTG FOOTING REV REVISION ASSY ASSEMBLY FS FAR SIDE SCHED SCHEDULE B/ BOTTOM OF GA GAGE SECT SECTION BETWN BETWEEN GALV GALVANIZED SIM SIMILAR BOT BOTTOM GC GENERAL CONTRACTOR SPEC SPECIFICATION BM BEAM SQ SQUARE BLDG BUILDING- HGT HEIGHT STD STANDARD BPL BASE PLATE HORtZ HORIZONTAL STIFF STIFFENER BRG BEARING HSA HEADED STUD ANCHOR STL STEEL H T HEIGHT STR STRAIGHT C TOC CENTER i0 CENTER CANT CANTILEVER IF INSIDE FACE STRUCT STRUCTURAL CJ CONSTRUCTION JOINT INT INTERIOR SYM SYMMETRICAL rL OR CL CENTER UNE JT JOINT T&B TOP AND BOTTOM CLR CLEAR LB POUND T/ TOP OF CMU CONCRETE MASONRY UNIT LG LONG T/u PANEL 11LT-UP PANEL COL COLUMN LLH LONG LEG HORIZONTAL TE THICKENED EDGE CONIC CONCRETE LLV LONG LEG VERTICAL THK THICK CONN CONNECTION LSH LONG SIDE HORIZONTAL THRD THREADED CONST CONSTRUCTION LSV LONG SIDE VERTICAL TRANSV TRANSVERSE CONT CONTINUOUS TS THICKENED_ SLAB 'CONTR CONTRACTION MANUF MANUFACTURER n.P TYPICAL^ CTR CENTER MAT'L MATERIAL LION UNLESS OTHERWISE NOTED C7RD CENTERED MAX MAXIMUM MECH MECHANICAL VER VERIFY DBA DEFORMED BAR ANCHOR MIN MINIMUM VERT VERTICAL DEFL DET DEFLECTION DETAIL YISC MISCELLANEOUS W/ WITH DIAG DIAGONAL NIC NOT IN CONTRACT W/0 WITHOUT DIA DIAMETER NO NUMBER WS WATER STOP DIFF DIFFERENT NTS NOT TO SCALE WWF MELDED MARE FABRIC DIM DIMENSION NS NEAR SIDE DO DITTO GENERAL SYMBOLS DWG DRAWING OC ON CENTER OU OUTSIDE DIAMETER ,PLAN SECTIOR TAIL NO. EA EACH OF OUTSIDE FACE NUMBER EF EACH FACE EJ EXPANSION JOINT 0/0 OUT TO OUT ® NORTH ARROW EL ELEVATION OPNG OPENING ELEC ELECTRICAL OUP OPPOSITE ELEV ELEVATOR PERP PERPENDICULAR �J/ 0- KEYED NOTE TO PLAN ENGR ENGINEER It OR PL PLATE ED EQUAL PNL PANEL O FOUNDATION TYPE EQUIP EQUIPMENT PREFAB PREFABRICATED Q REVISION NUMBER EXIST EXISTING PSF POUNDS PER SQUARE FOOT EXP EXPANSION PSI POUNDS PER SQUARE INCH T FOOTING STEP CITY QUANTITY DESIGN CRITEMA DESIGN PER 2007 FLORIDA BUILDING CODE WITH 2009 SUPPLEMENTS, UNLESS OTHERWISE NOTED. LIVE LOADS: STAIRS. 100 PSF GRATING 00 PSF CONCRETE (DESIGN PER CURRENT EDITION ACI 318) ALL CONCRETE ..... ..... ..... ... FC. 4000 PSI ALL REINFORCING STEEL ASN A615 GRADE 60. REWIFOtONG STEEL SHOWN ON MESE DRAWINGS TO BE WELDED SHALL BE ASTM A706. ALL WELDED WIRE FABRIC ASTM A85 GENERAL NOTES UNLESS OTHERWISE NOTED (LION) ON THE DRAWINGS, MINIUM COVER FOR REWORDING SHALL BE AS FOLLOWS FOOTNGS.......-..................... ........................ .... ......... ........ ............................................ 3" MATS ANO WALLS (EXPOSED TO EARN, LIQUID OR WEATHER) .............................. Z' SLABS AND WALLS (NOT EXPOSED TO EARN. UOUID OR MEANER) ..................... )L' ALL RENFORONG SMALL BE HELD SECURELY N POSITION NN STANDARD ACCESSORIES N CONFORMANCE NN CRS MANUAL OF STANDARD PRACTICE AND ACI 315 DURING THE PLACING OF THE CONCRETE. ALL HOOKS N REINFORCING BARS SHALL BE AN ACI STANDARD HOOK. UNLESS OTHERWISE NOTED. DOWELS FROM FOUNDATIONS OR SLABS TO WALLS SHALL MATO/ WALL REINFORCING, UNLESS OT ERWSE NOTED. DOWELS SHALL BE PLACED BEFORE CONCRETE IS POURED. THEY SHALL NOT BE PUSHED INTO THE CONCRETE. PROVIDE V CHAMFER AT ALL EXPOSED CORNERS OF BEAMS, WALL, ETC. ALL CONCRETE MIXES SHALL BE PROPORTIONED BY ME FIELD EXPERIENCE METHOD OR THE LABORATORY TRIAL MEMOD IN ACCORDANCE WAN ACI 318: MAXIMUM WATER/CEMENT RATIO SHALL BE 0.45. FDIIMDATIONS IF FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, UNSTABLE, OR UNSUITABLE SO.. THE ENGINEER SHALL BE NOTIFIED. STEPS IN WALL FOOTNOS SHALL NOT EXCEED A SLOPE O (1) VERTICAL TO TWO (2) HORIZONTAL. MINIMUM R I IN . & STAIRS HANDRAILS AND STAR RAILS SHALL BE DESIGNED TO WITHSTAND A 200/ CONCENTRATED LOAD APPLIED N ANY DIRECTION AT ANY PONT ON THE TOP RAL. HANDRAILS ANO STAIR RAILS SMALL ALSO BE DESIGNED TO WTHSTAND A LOAD O 50//FT APPLIED HORIZONTALLY TO THE TOPRAL. THE 200f LOAD WILL NOT BE APPLIED SIMULTANEOUSLY ON TE 50//FT LOAD. IN ADDITION, ME HANDRAILS SHALL BE DESIGNED TO WITHSTAND A LOAD OF 100#/FT APPLIED VERTICALLY DOWNWARD TO ME TOP RAL AND SIMULTANEOUSLY WITH THE 50i/FT HORIZONTAL LOAD. THE 100//FT VERTICAL LOAD DOES NOT APPLY TO STAIR RAILS. STAIRS SHALL BE DESIGED TO WITHSTAND THE LOADS DEFINED IN ME DESIGN CRITERIA. THE MANUFACTURER SHALL SUBMIT SIGNED AND SEALED CALCULATIONS AND SHOP DRAWINGS TO THE ENGNEER FOR APPROVAL. POST SPACING SMALL BE A MAXIMUM O B' -O POSTS ANO RAILINGS SHALL BE A "NUM OF UI` SCHEDULE 40 ALUMINUM PIPE ALLOY 8108-T5. ASTM -B-429 OR ASTM -8-231. ME HANDRAIL 94ALL BE MADE O PIPES JOINED TOGETHER WIN COMPONENT FITTINGS. COMPONENTS THAT ARE POP -RIVETED DR GLUED AT ME JOINTS WILL NOT BE ACCEPTABLE. ALL COMPONENTS MUST BE MECHANICALLY FASTENED WITH STAINLESS STEEL HARDWARE. HANDRAIL AND COMPONENTS SHALL BE AS MANUFACTURED BY THOMPSON FABRICATING COMPANY (BIRMINGHAM, ALABAMA) OR APPROVED EQUAL. POSTS SHALL NOT INTERRUPT THE CONTINUATION O THE TOP RAIL AT ANY PONT ALONG ME RALIING. INCLUDING CORNERS AND END TERMINATIONS. ME TOP SURFACE O THE TOP RAILING SHALL BE SMOOTH AND SHALL NOT BE NTERRUPTED BY PROJECTED FITTINGS. ME NDIRAL AT A CORNER RETURN SHALL BE ABLE TO WITHSTAND A 200/ LOAD WITHOUT LOOSENING. THE MANUFACTURER IS TO DETERMINE THIS DIMENSION FOR THEIR SYSTEM. PROVIDE PHYSICAL TESTS FROM A LABORATORY TO CONFIRM COMPLIANCE. EXPANSION BOTS SMALL BE SPACED IOW APART AND 5• EDGE DISTANCE FOR NO REDUCTION IN PULLOUT STRENGTH, A SAFETY FACTOR OF "4"- SHALL GE USED ON EXPANSION BOT PULLOUT VALUES PUBLISHED BY THE MANUFACTURER. EXPANSION BOLTS SHALL BE STAINLESS STEEL TYPE 18-8 WEDGE BOLTS AND SHALL BE FURNISHED BY THE HANDRAIL MANUFACTURER. TOE PLATE SHALL BE A MINIMUM OF 4' MGH AND SHALL BE AN EXTRUSION NAT ATTACHES TO ME POSTS WTH CLAMPS WINCH WILL ALLOW FOR EXPANSION AND CONTRACTION BETWEEN POSTS. TOE PLATES SMALL BE SET (" ABOVE THE WALXNG SURFACE. FINISH SHALL BE ALUMINUM ASSOCIATION M10 -C22-441 (215-R1). THE PIPE SMALL BE PLASTIC -WRAPPED. ME PLASTIC WRAP IS TO BE REMOVED AFTER ERECTION. ALUMINUM SURFACES IN CONTACT WITH CONCRETE. GROUT OR DISSIMILAR METALS WILL BE PROTECTED WIN A COAT OF BITUMINOUS PAINT, HYLAR ISOLATORS OR OTHER APPROVED MATERIAL. ALUMINUM GRATING GRATING SHALL BE FABRICATED OF ALUMINUM I -SHAPED BARS. ALLOY 6063-T6, WITH SWAGED CROSS BARS SPACED ON 4' CENTERS 13EAMNC BARS SHALL BE SPACED ON l I." CENTERS. TOP SURFACE OF BEARNG BARS SHALL BE STRIATED TO PROIOE A NONSUP SURFACE. PLANKING 91A1. BE EXTRUDED FROM ALUMINUM ALLOY 6063-T6. TOP SURFACE SMALL BE PUNCHED (NN UPSET EDGES) OR ND UNPUNCHED, AS SPECIFIED ON THE PLANS, A SHALL HAVE CONTINUOUS STRIATIONS FOR SKID RESISTANCE. STANDARD NSTMLATION CLEARANCES AND TOLERANCES SHALL CONFORM TO THE REDUREMENTS OF ME CURRENT METAL BAR GRATING MANUAL PUBLISHED BY THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS INSTALL ALUMINUM CLAMPS OR CUPS TO ANCHOR GRATING AND PLANKING TO SUPPORTS A MINIUM O FOUR FASTENERS IS REQUIRED PER PANEL UNLESS OTHERWISE NOTED ON THE DRAWINGS CLIPS SMALL NOT PROTRUDE ABOVE THE TOP OF THE GRATING. CUTOUTS FOR CIRCULAR OBSTRUCTIONS TO BE AT LEAST 2' LARGER IN DIAMETER MAN THE OBSTRUCTION. CUTOUTS FOR ALL P1P1NG 4' AND LESS IN DIAMETER TO BE MADE IN THE FIELD. ALL OPENINGS WHERE MORE THAN FOUR BEARNG BARS ARE CUT SHALL BE BANDED NM BAR THE SAME DEPTH AS ME BEARING BARS. THE ENDS OF ALL GRATING AND PLANKING PANELS SHALL BE BANDED. SHELF ANGLES SHALL BE ANCHORED TO CONCRETE WITH TYPE 18-8 STAINLESS STEEL WEDGE ANCHORS ALUMINUM STAR TREADS SHALL BE I -BAR GRATING TYPE TREADS AND SHALL BE I MI FL S14ED WITH EXTRUDED ALUMINUM CORRUGATED NOSING. ALUMINUM CARRIER ANGLES SHALL BE MELDED TO ME ENDS O STAR MEADS MINIMUM DEPTH O GRATING AT TREADS SHALL BE to". ALUMINUM SURFACES IN CONTACT NTH CONCRETE OR DISSIMILAR METALS SHALL BE PROTECTED WITH A COAT O 8111UMIIOUS PANT. aWPI NT PY NO � PROVIDE ALL TEMPORARY BRACING. SHORING, GUYING OR OTHER MEANS TO AVOID EXCESS A STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. THE STRUCTURE SHOULD NOT BE CONSIDERED STABLE UNTIL ALL STRUCTURAL ELEMENTS HAVE BEEN CONSTRUCTED IN ACCORDANCE WN THE CONTRACT DOCUMENTS. MCVEIGH & MANGUM ENGINEERING. INC OR ANY OF ITS EMPLOYEES SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES OR SEQUENCES FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING ME WORK, OR FOR THE FAILURE OF ANY OF THEY TO CARRY OUT THE WORK N ACCORDANCE WITH THE CONTRACT DOCUMENTS, VERIFY ALL DIMENSIONS NTH MECHANICAL ORAWNGS. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES. ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL AND PLUMBING EOUIPMENT SHALL BE VERIFIED NTH EOUPMENT PURCHASED BEFORE PROCEEDING WN STRUCTURAL WORK AFFECTED. CONTRACTOR SMALL VERIFY ALL EXISTNG DIMENSIONS AND CONDITIONS OF EXISTING STRUCTURE AND SITES THAT ARE AFFECTED BY NEW WORK BEFORE PROCEEDING NM FABRICATION AND CONSTRUCTION. EMBEDMENT FOR EXPANSION BOLTS SHALL BE 44" MINIMUM FOR %"* BOLTS IN CONCRETE OR GROUTED MASONRY. MITI KW BOLT 3 OR EQUAL EPDXY GROUT SHALL BE HnSO CARTRIDGE SYSTEM BY HILT: (MILT[ RE500, IF HOLE IS CORED INSTEAD OF DRILLED) OR APPROVED EOUAL. LION. EMBEDMENT SHALL BE 12 BAR DIAMETER MINIMUM, UON. HOLES SHALL BE A" LARGER MAN REBAR 92E AND IL" LARGER NAN THREADED ROD SIZE. HOLE SHALL BE BRUSHED OUT WITH BOTTLE BRUSH AND MEN BLOWN OUT NTH MR USING A COMPRESSOR NTH A FUNCTIONAL OIL TRAP. INSTALLATION SMALL BE IN ACCORDANCE NTH MANUFACTURERS PRINTED INSTRUCTIONS. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SMALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT. GENERAL CONTRACTOR MUST RENEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO ENGINEER. SUBMITTALS WHICH 00 NOT CONTAIN THE CONTRACTOR'S SHOP DRAWING STAMP OR HAVE BEEN MERELY *RUBBER STAMPED" SHALL BE RETURNED WTHOUT REVIEW. CHANGES TO ME CONTRACT DOCUMENTS SHALL BE CLOUDED ON 940P DRAWINGS OR REQUESTED IN WRITING. THE CONTRACTOR IS LIABLE FOR ANY DEVIATIONS UNLESS REVIEWED AND ACKNOWLEDGED BY THE ENGINEER. SHOP DRAWING SUBMITTALS SHALL ONLY BE CHECKED FOR CONFORMANCE NTH THE DESIGN CONCEPT AND THE INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS. HYDROSTATIC TESTING OF [OIG ETE TANKS WELLS & CHANNELS IT IS THE INTENT THAT ALL TANKS, FELLS. & CHANNELS DESIGNED TO HOLD OR CONVEY SEWAGE OR DERIVATIVES THEREOF, WILL DO SO WTHOU7 LEAKS OR WEEPS. PRIOR TO INTRODUCTION OF SEWAGE & AS A CONDITION OF SUBSTANTIAL COMPLETION, ALL CONCRETE TANKS. WELLS AND CHANNELS SHALL BE INDIVIDUALLY HYDROSTATICALLY TESTED FOR GROUNDWATER INFILTRATION, WHERE APPUCABLE & EXFILTRATION, ALL CONCRETE WALLS, COVERS, & BOTTOMS SHALL BE SUBJECTED TO VISUAL INSPECTION FOR HYDROSTATIC LEAKAGE AS WELL AS OTHER FAULTS OR DEFECTS, & ANY LEAKAGE OR OTHER M98LE DEFECT SHALL BE CORRECTED O ONCE. INVESTIGATION & REPAIR OF LEAKS & WEEPS SMALL BE PERFORMED AFTER COMPLETION OF PREPARATION AND PAINTING OF SURFACES SUBMERGED BY SEWAGE OR DERIVATIVES THEREOF. HOWEVER, TESTING & REPAIR SHALL BE CONDUCTED PRIOR TO THE APPLICATION OF CEMENTITIOUS COATING SPECIFIED. IN ANY EVENT, LEAKS & WEEPS WHICH ARE EVIDENCED PRIOR TO, DURING. OR AFTER PREPARATION & PANTING OPERATIONS SHALL BE REPAIRED IMMEDIATELY, & PRIOR TO, CONTINUING SUCH OPERATIONS. ALL HYDROSTATIC TESTING SHALL BE PERFORMED BY THE CONTRACTOR WHO SHALL PROVIDE ALL NECESSARY EOUIPMENT & MONITORING SERVICES REQUIRED. THE CONTRACTOR SHALL MAKE ARRANGEMENTS FOR & PAY ALL COSTS O WATER REOURED TESTING. WATER RESOURCES CONSIDERED ACCEPTABLE ARE: THE CITY/COUNTY WATER SUPPLY: TREATED PLANT EFFLUENT, IF AVAILABLE; & GROUNDWATER, IF THE PLANT EFFLUENT IS USED, IT LUST BE CHLORINATED PRIOR TO SPENT WATER DISCHARGE INTO THE REGULAR RECEIVING WATERS. ALL SURFACES PANTED OR LINPANTED. WHICH WILL NOT REMAIN SUBMERGED AFTER TESTING, & WHICH WERE COVERED OR SPLASHED WITH PLANT EFFLUENT WATER DURING TESTING, MUST BE SCRUBBED AFTER TESTING, IN ORDER TO PREVENT _ DEVELOPMENT O DOOR, IF GROUNDWATER USED. IT MAY BE NECESSARY TO SCRUB NESE SAME CONCRETE SURFACES COVERED OR SPLASHED BY IT TO REMOVE STAIN. IT MAY ALSO BE NECESSARY TO CHLORINATE GROUNDWATER USED FOR TESTING PRIOR TO DISCHARGE INTO THE REGULAR RECEIVING WATERS. VISIBLE INFILTRATION. SUCH AS THAT SEEPING THROUGH SHRINKAGE CRACKS. SHALL BE ALLOWED A PERIOD OF ONE WEEK TO "HEAL". IF INFILTRATION DOES NOT CEASE, THE CONTRACTOR SHALL TAKE WHATEVER STEPS NECESSARY TO REPAIR THE LEA( OR WEEP, AS WELL AS ANY OTHER GROUND WATER INFILTRATION THAT MAY BE APPARENT TO THE SATISFACTION OF THE ENGINEER. CONCRETE TANKS, WETWELLS, & CHANNELS SHALL BE INDIVIDUALLY FILLED NTH WATER SOURCES AS DEFINED ABOVE TO ME MAXIMUM DESIGN OPERATION LEVEL O EACH UNIT & MAINTAINED AT THIS ELEVATION FOR A PERIOD O ONE WEEK. THE TERM "INDIVIDUALLY FILLED', ALLOWS NON -ADJACENT TANKS, WETWELLS, & CHANNELS TO BE FILLED, NUS PERMITTING THE CHECKING FOR LEAKAGES INTO THE ADJACENT STRUCTURE. THE TESTING OF WATER TIGHTNESS SHALL BE IN ACCORDANCE WITH A0350.1. VISIBLE LEAKAGE OR WEEPS THAT DO NOT CEASE WITHIN A WEEK, MUST BE REPAIRED BY ME CONTRACTOR TO THE SATISFACTION O ME ENGINEER. UNDERGROUND LEAKAGE EVIDENCED BY DEVELOPMENT OF WET AREAS AROUND ME PERIPHERY OF THE STRUCTURES, MUST BE INVESTIGATED BY ME CONTRACTOR & THE SOURCE OF THE LEAKAGE REPAIRED. ANY TANK STRUCTURE. WHICH INDICATES A LOSS OF WATER, IN ACCESS OF OJX OF THE WATERVOLUME IN A 24 HOUR PERIOD MUST BE INVESTIGATED By THE CONTRACTOR FOR LEAKAGE & WATER POSSIBLY RETAINED IN SAID STRUCTURE FOR A PERIOD OF 2 TO 3 WEEKS IN CONTRACTOR'S EFFORT TO LOCATE LEAKAGE It MAKE ALL NECESSARY REPAIRS UPON THE SUCCESSFUL COMPLETION OF TME ABOVE DEFINED HYDROSTATIC TESTING. ME TEST WATER SHALL REMAIN IN THE VARIOUS STRUCTURES AT MAXIMUM OPERATING LEVELS PRESCRIBED ON ME CONTRACT DRAWINGS FOR THE PERFORMANCE O OTHER TESTING & ADJUSTMENTS SET FORTH IN THESE SPECIFICATIONS, UNTIL ISSUANCE OF SUBSTANTIAL COMPLETION FOR THE ENTIRE FACILITY. THE CONTRACTOR SHALL PROVIDE MAKE-UP WATER REQUIRED TO MAINTAIN THESE PRESCRIBED OPERATING LEVELS. UPON ISSUANCE OF SUBSTANTIAL COMPLETION. THE FACILITY WILL BE PLACED IN OPERATION & TEST WATER DISPLACED WITH SEWAGE & DERIVATIVES THEREOF. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE CHLORINATION AS RECURRED TO THE CONTROL GROWN O ALGAE & DEVELOPMENT OF ODOR DURNG THE CONTAINMENT OF TEST WATER, PRIOR TO SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR CHLORINATION & CHLORINE CONTENT O ANY TEST WATER DISCHARGED PRIOR TO SUBSTANTIAL COMPLETION. BUT NOT AFTERWARDS. CONCRETE WORK SHALL CONFORM TO THE REQyIP�i(FjN� BEACH CONCRETE "SPECIFICATIONS FOR STRUCTURAL CONCRETE E RI BUIL C(�TLJOI EXCEPT AS MODIFIED BY ME REQUIREMENTS OF THE PING OFFICE FEB O l 2111 // } /11 By: iFv\,N. 0 1 •••••M••••, ��aYoo GEN % • • 1 • No. 52 ° R. ° • ro S" OF s'�t, Ad�IA •0a• � d 0•a i 0 W®moi Ve�` g(•yWg�o� �`a''j+, ,�4� &At MCVEIGH & MANGUM t. ENGINEERING•INC 9133 R.6. $Almlaf Parkway 483 5lle, PlwiEa 3223fi PL: (901)483-52(q Pax: (904)6366]]0 Tie 6330 wail: mul®Mcve��t.HauW�an.com PnW. oreaaa: rim w. oa® Lam.. Ha.: stns DESIGN CRITERIA do GENERAL NOTES ISSUED FOR BIDS 11/4/2010 ADDENDUM /2 11/17/2010 NO W Z Q J CL O J 0 cz O LLR L.L. 0 Z � W :5 - Lu O CL P. 'FF CL H 3 0 i A1° SEPTEMBER 2010 CALF AS SHOWN RAWN BY RMF ESIGNED BY TWO HEET SO.1 46 OF 72 SHEETS EXOSTING PIPE TYP REVISIONS ISSUED FOR BIDS 11/4/2010 ADDENDUM J2 11/17/2010 PROJECT FILE NO j CONIC WALL "B" 2 SEE DET 2/S2.1 52.1: CONC WALL "A" I �AY SEE DET I/S2.1 I N_ `— EVSTING CONC CHAMBER SLAB U N N C J N ' IL c W (0 N ai @2 to T _ _ 52.1 C N to c N r TYP CONIC WALL -Q to 173 Y N _j' INTERSECTIONS U Q K Ip N 2 1 'o I i !� OUSTING CONIC JI CHAMBER WALL. TYP in I - --- E U i o m CL ! i ( 0 U ' J L 2 CONIC WALL "B" SEE DET 2/52.1 CONIC WALL "A" Cie52.1 4' 0"x4' -0"x1'-0" FTC A �tL SEE DET 1/52.1 W/5 -r5 BARS EA WAY O BOTT OF FTC O LL D i N r I: r ILL ol SLE MECH FOR OPEIANc r 1 LOWER FOUNDATION PLAN 1-7Z - El151iNG CONIC LOCATIONS TYP 'f-------- LO J 51.1 SCALE: 3/32" 1'-0" N W CHAMBER SLAB {r- PLAN NOTES 1) ME 50.1 FOR DESIGN CRITERIA AND GENERAL NOTES piluorie9erinA;4� i 2 SEE DETAIL 4/52,1 FOR REINF O WALL CORNERS AIN 8tJ _ - r , - 3) SEE DETAIL 4/52.1 FOR REINi O WAIL AND SLAB O Oe 4) SEE SCHEDULE 1/S2.2 FOR RERIF SPLICE. �� y �� y ' L 5) CONTRACTOR TO COORD WALL OPENING LOCATI Cw/'�•p•....... G 1 6) JOINTS R. AND CONSTRUCTION WITH ME FOR WALL OR SLAB SHALL FOLLOW D�I� 3 --# ` ®`d �'"1�6J • p - .'-... ..__._ CONC CHAMBER ABOVE. u ®• V s ^- SEE SHEET SI.2 a No. t b 12"x12" CONIC COL o s a. CL 2 1 W/ (8) 15 VERT BARS a i 8: r3 TIES O 8" OC ,y • 52.1 52.1 � 76 • • 5 p 3 18 X16*)1' TYPO EXISTING ''.. 0 pps � x WALL wTERSECTION '..� ✓I✓✓ Q,� ,,((�� �Ms'`�V. "' ®® ALUMINUM CANOPY COL N. ( �___ _ — _ — _ )( ✓O'4E4�t� w ev6+ed4a%9 DATE SEE 7/Sa3. MN sze �-� SEPTEMBER 2010 3'x3" (TMP AT EA CORDER) I _ I _5. _: –o - _ -—r--�"-�"�_ -I - —O M cVEIGH MAN GUM SCALE j K1„1 a — — f ENGINEERING -INC AS SHOWN —1 >.:r`, ; EXISTING STAIR POSTS - RMF j PPE TYP ALUMRNRA VERIFY */STAIR YANUF irx,on um P1^oon��arXrn=r DRAWN BY 5” SLAB ON GRADE I -O" STAw TW £B 6330 eme 13-m.W Pu Inoej a36e-eno �TA+ov��xAnr.^¢w�.wm DESIGNED BY W/r3 BARS O 12" OC L — -b 8' CONIC SL W/ £^s ^rx�.a r n, w o...^ 52735 P2/0 EACH WAY 52,3 ROOF OUIIJNE r] BARS O 12" OC EW s'-0"x8'-6"xl'-0" FTG """` PRONDE 12"x8" WIDE W/15 BARS O 10" DC SHEET $" MGH CURB THICKENED EDGE O EA WAY O BOTT OF FTC 4'- 16'-2A' PERIMETER AERATION TANK MODIFICATIONS LOWER PLAN TYP 47 OF 72 • SHEETS Z } r EXOSTING PIPE TYP REVISIONS ISSUED FOR BIDS 11/4/2010 ADDENDUM J2 11/17/2010 PROJECT FILE NO j CONIC WALL "B" 2 SEE DET 2/S2.1 52.1: CONC WALL "A" I �AY SEE DET I/S2.1 I N_ `— EVSTING CONC CHAMBER SLAB U N N C J N ' IL c W (0 N ai @2 to T _ _ 52.1 C N to c N r TYP CONIC WALL -Q to 173 Y N _j' INTERSECTIONS U Q K Ip N 2 1 'o I i !� OUSTING CONIC JI CHAMBER WALL. TYP in I - --- E U i o m CL ! i ( 0 U ' J L 2 CONIC WALL "B" SEE DET 2/52.1 CONIC WALL "A" Cie52.1 4' 0"x4' -0"x1'-0" FTC A �tL SEE DET 1/52.1 W/5 -r5 BARS EA WAY O BOTT OF FTC O LL D i N r I: r ILL ol SLE MECH FOR OPEIANc r 1 LOWER FOUNDATION PLAN 1-7Z - El151iNG CONIC LOCATIONS TYP 'f-------- LO J 51.1 SCALE: 3/32" 1'-0" N W CHAMBER SLAB {r- PLAN NOTES 1) ME 50.1 FOR DESIGN CRITERIA AND GENERAL NOTES piluorie9erinA;4� i 2 SEE DETAIL 4/52,1 FOR REINF O WALL CORNERS AIN 8tJ _ - r , - 3) SEE DETAIL 4/52.1 FOR REINi O WAIL AND SLAB O Oe 4) SEE SCHEDULE 1/S2.2 FOR RERIF SPLICE. �� y �� y ' L 5) CONTRACTOR TO COORD WALL OPENING LOCATI Cw/'�•p•....... G 1 6) JOINTS R. AND CONSTRUCTION WITH ME FOR WALL OR SLAB SHALL FOLLOW D�I� 3 --# ` ®`d �'"1�6J • p - .'-... ..__._ CONC CHAMBER ABOVE. u ®• V s ^- SEE SHEET SI.2 a No. t b 12"x12" CONIC COL o s a. CL 2 1 W/ (8) 15 VERT BARS a i 8: r3 TIES O 8" OC ,y • 52.1 52.1 � 76 • • 5 p 3 18 X16*)1' TYPO EXISTING ''.. 0 pps � x WALL wTERSECTION '..� ✓I✓✓ Q,� ,,((�� �Ms'`�V. "' ®® ALUMINUM CANOPY COL N. ( �___ _ — _ — _ )( ✓O'4E4�t� w ev6+ed4a%9 DATE SEE 7/Sa3. MN sze �-� SEPTEMBER 2010 3'x3" (TMP AT EA CORDER) I _ I _5. _: –o - _ -—r--�"-�"�_ -I - —O M cVEIGH MAN GUM SCALE j K1„1 a — — f ENGINEERING -INC AS SHOWN —1 >.:r`, ; EXISTING STAIR POSTS - RMF j PPE TYP ALUMRNRA VERIFY */STAIR YANUF irx,on um P1^oon��arXrn=r DRAWN BY 5” SLAB ON GRADE I -O" STAw TW £B 6330 eme 13-m.W Pu Inoej a36e-eno �TA+ov��xAnr.^¢w�.wm DESIGNED BY W/r3 BARS O 12" OC L — -b 8' CONIC SL W/ £^s ^rx�.a r n, w o...^ 52735 P2/0 EACH WAY 52,3 ROOF OUIIJNE r] BARS O 12" OC EW s'-0"x8'-6"xl'-0" FTG """` PRONDE 12"x8" WIDE W/15 BARS O 10" DC SHEET $" MGH CURB THICKENED EDGE O EA WAY O BOTT OF FTC 4'- 16'-2A' PERIMETER AERATION TANK MODIFICATIONS LOWER PLAN TYP 47 OF 72 • SHEETS SUED FOR BIDS 1/4/2010 PROJECT m FRE NO i - ---- A T -- - -- r I CONCRETE WALKWAY AND LATERAL BEAM B ® TYPE A, I ! I I SEE DETAIL 1/52.1 I I 6 S2.1 CONCRETE WALKWAY I II ® m ® TYPE D, 6 SEE DETAIL 6/'51.2 I I J i s2s I I, L I CID m Y 13 r- U N N IT cm izL-5 a TYPE CONCRETE WALKWAY C Lu (� 6 I SEE DE AIL 6/52.1 I C .O M C N r - - NOTCH EXISTING WALL - O ' ____ 0WALKWAY,TYP 52.1 'i 11 ty+ ()US 10 Y N I_ _ _ _ _ I (SEE DETAIL 8/52.2) i i L .. - 8 Q '- l N "• PIPE C==:::z::::- , 11 I SPACED � I I SPACED � o+ O 10MAX SECT 7 I I I SEE sEcr 2/52.1 ---- ' i 1L I I w II Z `4��iyl1$IINI!!/!i!/yt J — — — I_� • 0.•..... ® ! 2 , — H ••`f' EN , O ' 5 I 52.1v`J ;•00 U 2.2 J E_== ---- i ; L — CONCRETE WALKWAY ,I L .. - . _ _ _ _ _ _ i TYPE D. ! 1I 2 CHUANNELI m 7� • 1Ow SEE DETAIL 6/S2.2 ® 523 C8:125 3 • Cr • LL PLUG 6". °ROP INLETS BY INCREASING THE OPENING I w 10'-0" A •• r ( • �V�J O ---- 512E BY Y " ON TNAN THE OF THE SRL AND TO : I I APPE ANCE WILL BE SIMILAR TO A COUNTERSUNK HOLE- (3) OPENINGS AT THE TOP OF THE WALL IN THEs>e' .� N 1 DEPTH OF 2" ON EACH FACE OF THE WALL (FINAL I I I I i Tj� .11y9I��E5 • BOX. EACH OPENING IS 2'-8" WIDE a 2'-2A" DEEP, �j • � � N y 9 I ON EACH FACE.) OVA1E A CRDNUg15 WARSTOP I I 5 Zr CENTER Tiff OPENINGS W/1N THE WIDTH OF THE WALL. `••OMM;rti1i.•••r�� ® Z V i u . + SEE 9/52.1 (VERIFY OPENING 92E w/MECH) �g.. ®a' ® L IN THE OPENING AND PLUG THE OPENING - y�yui 52.2 I WITH 5.000 P9 NON -SHRINK ROUT. (TMP) I 52.2 j ,yAP. Ii pl ZY+ _ "!� w CM 11 -7_ - - - -O UPPER PLAN r - - - -' - - - J 1 5,.2 SCALE: 3/32" ' ,'-0" IN i -\JJ7 O a EXISTING ELEVATED I I I I CONCRETE WALKWAY 1 it -2.PLAN NOTES ® - TRENCH, ETYPLEVATED I 1 : TYPE C. 1) SEE SO.1 FOR DESIGN CRITERIA AND GENERAL NOTES. CL E DETAIL 6/52.1 I n 2) CONTRACTOR TO CORD WALL OPENING LOCATIONS FOR STOP GATE �_..' PROVIDE 1'-0" THICK CUT-OFF WALL. I I 6 r Y i WEIR. AND CONSTRUCTION WITH MECH. o 3) T/SLAS ELEVATION =+100'-0"(REF NGVD+=1&0') VERIFY WITH C@1L. _ ---- RENF W/ 15 BARS O 8 -OC EA FACE, EW. I _ ' EPDXY {' INTO EXIST W/ HILTI HY-150 (TYP) 1 L„_„ $1,1 RA EIR GO TE !) TOP OF WALL ELEVATION .. _.. .. _.._.. _,._.. _.. _..J SEE WE H TR OF WALKWAY ELEVATION = +118-6 Rik1 I ® _ •I 5) DENOTES RB ASS MESH AND RATING, SEE SPECS. 0 YIN RATING DEPTH IS Y ANO YIN SECTION PROPERTY IS CL i BASED R 4CALL AIN 5-200 G'SFIBERGLASS ECOM RATING, I X-_0” CONNECT TO ALL FRAYING PER MFG'S RECOMMENDATIONS. PUMP SEE MECH - I 6) —"— DENOTES ALUMINUM HANDRAILS, SEE DETAIL 2/S2.2. I T7-0" WIDE z 2'-6" DEEP OPENING CUT IN EXISTRIC WALL AT TOP OF; WALL (TYP) FR GATES. SEE 8/92.1 m rill ! I I I (VERIFY OPENING SRE W/11ECH), K Aw J -- —-— -- ---- ' DATE SEPTEMBER 2010 M CVEIGH & MANGUM SCALE AS SHOWN ^a ALUMINUM E N G IN E E R T N G - I NC STAIRS BY YANUF DRAWN BY TYP O WALKWAY 5 0 STEPS 5'-0" 10 STEP STAIR POSTS AND LANDING, vlss K.c. slrlm,« ra.tw- RMF EXISTING WALL 52.1 _ BY STAIR YAN1F 1.at. IS F—,N 32256 INTERSECTION VERIFY W/ STAIR YANUF 5-0" TYP - EB 330 eme83 me>;IQQ MCVegliMen3gum2Jcem DESIGNED BY TWO ..reQ.rd: T®w. w,® I-- stns SHEET AERATION TANK MODIFICATIONS UPPER PLAN S1.2 4$ OF 72 SHEETS V i I I I I I I I I I I I I I I I I I I I I I I 1 I I 1 I I I I I I 1 I I I I I I I T/PLATFORM SEE PLAN I 07 O 8"OC I I SEE 2/S2.2 FOR 1 I I Es TYPICAL RAIL _ DETAIL = LATERAL BEAM W/(20) IF9 BARS • • & a5 TIES O 12 -OC s. NOTE /8 O 6"OC VERT— ALL HORIZ BARS ARE EPDXIED INTO EXISTG SIDE WALLS. ALSO PROVIDE WATERSTOP IN BETWEEN PROVIDE WATERSTOP BETWEEN ,.. NEW AND EXISTING WALL AS SHOWN O SECT 3/S2.1 NEW V-0" PEINF CONC WALL, TYP EO _ 4-a4 DOWELS W/ NEW V -O" REINF 180' HOOK O 18"OC t �. EPDXIED INTO E1aITG DRAWN BY RMF CONC TYP Ph: (901)483-52M Pu: (9 )63-0 ee 633o em.u: Rl.ilc�4lucve;glNl.RBum.cmn Eug. ofRecoN: Tim W.Ovm Lisnx Ne.: 53'I35 DESIGNED BY TWO 1) ALL HOOKS ARE T/EXISTG CONIC. SECTIONS AND DETAILS SEE uECH 3 6-06 HORIZ EQUAL SPA 3 VLALL & WALKWAY TYPE •A" 1 'SECTION -- ALL CONDUIT SHALL BE CENTR'D WITHIN SLAB (MAX SIZE OF GROUPED CONDUIT - 2'-0"X8") —05 HORIZ a 8 -OC = U i 3 BAR LAP, S SEE 1/52.2 0 CONC FTG ED REINFORCED N W/a8 O 6"OC y T&B WATER STOPS, SEE DET 3/S2.1 TYP WIDTH, SEE WATE SEE DE' DOWELS TO VERT WAL DRILL AND EPC EXISTII xc A.c�n w 07 O 8"OC REINFORCING ••i EW EF .-LUENT��s••�/\ R DOX � \Cie 0- OTE ` • • ALL LL HORIZ. BARS ARE EPDXIED s. To PRIOR TO SEALANT INTO EXISTG SIDE WALLS. ALSO PROVIDE WATERSTOP BETWEEN ,.. s NEW AND EXISTING O NOTES, WALL AS SHOWN O SECT DATE SEPTEMBER 2010 3/S2.1 s NEW V -O" REINF SCALE AS SHOWN CONC WALL, TYP DRAWN BY RMF Ph: (901)483-52M Pu: (9 )63-0 ee 633o em.u: Rl.ilc�4lucve;glNl.RBum.cmn Eug. ofRecoN: Tim W.Ovm Lisnx Ne.: 53'I35 DESIGNED BY TWO 1) ALL HOOKS ARE STD. 90'. SECTIONS AND DETAILS U WALL 3 WALL TYPE W 2 SECTION 52.1 SCALE: NTS I I I I I�DETAILCALRAIL SEE 2/S2.2 FOR-\ j 1 TYPICAL RAIL i PIPE DETAIL I I i I I I I i I I a5 DOWELS O 12 EPDXIED INTO EXISTG I I 1 I CONIC WALL CONIC WALKWAY, SEE I (2) W"• 55 & DETAILS 1/S2.1 & 6/S2.2 FORM EL. 1 T ATF M rl W SEE PLAN I ' i I I CONC WALKWAY W/8-ae MEC. PUMP PIPING T&B & a4 TIES O 8" OC PENETRATION EXIST CONC SEE 4/S2.2 FOR FOR WALL ALL CONDUIT SHALL BE REINFORCEMENT FOR _ CENTR'D WITHIN SLAB REINFgLCEMENT AT (MAX SIZE OF GROUPED WALKWAY TYPE = OPNG'S IN SLAB 5 SECTION GDNDDIT - 2' -D -XB") 6 SECTION 52.1 SCALE: NTS ST.1 SCALE: NTS HORZ REINF INTO EXISTING CONIC WALL, SEE DETAILS 1 & 2 S2.1 FOR WALL REINF PROVIDE CONT RX -100 SERIES WATER STOP BETWEEN EXISTING AND NEW CONCRETE WALL 2• CLR. TYP�' < 4-/8 O 6" OC EF VERT REINF TIP CONIC WALL REINF, SEE DETAILS 2" a 1 & 2 52.1 TYP II MATCH S12E AND SPACING OF HORIZ AND HORIZ REVISIONS ISSUED FOR BIDS 11/4/2010 ADDENDUM i2 11/17/2010 PROJECT FILE MO SIKH FLEX -1A— SEALANT BOTH SIDES, USE SIKA 429 PRIMER w e0 •o••eu• s• REINFORCING ••i .-LUENT��s••�/\ R DOX � \Cie 0- ` • • s. To PRIOR TO SEALANT E s NOTES, DATE SEPTEMBER 2010 CONC SCALE AS SHOWN ENGI N EERING•INC 9133 R.G. Skinner Pe.kway 1., FIonG 32256 DRAWN BY RMF Ph: (901)483-52M Pu: (9 )63-0 ee 633o em.u: Rl.ilc�4lucve;glNl.RBum.cmn Eug. ofRecoN: Tim W.Ovm Lisnx Ne.: 53'I35 DESIGNED BY TWO 1) ALL HOOKS ARE STD. 90'. SECTIONS AND DETAILS WALL INTERSECTION OF CONC WALL T -INTERSECTION l•MUFR RITERQ_C710N N c1 N TYP CONCRETE WALL INTERSECTION N N & EXISTING WALL DETAILSJ M N 3 DETAIL 4 DETAIL Sm a)-0,° C w LO m 52.1 SCALE: NTS 52.1 SCALE: NTS Icn,26 ON C SLIDE GATE. (OA Y SEE MECH O TA In U Q W N N WALWAY (TYP) IN WAWC()ENING T WAY SEE PLAN d 4 a a a Q ° ° a d EXISnNG ELEVATED - G O O O 0 0 W TRENCH (BEYOND) U a z Q d __ J __________________ a__________ ____ ___________ __ L ------------------ — — — — ----------- ---------- O °d J � �CC L O 1 EXISTING TANK DANDER NEW DANDER LL O i WALL (BEYOND) WALL (TYP) B SECTION z U) ALUM �T7.5s7.5a9.46 YYYYYY 52.1 SCALE: NTS ��} e0eeaesaaaaaaaar re LL • SS AN HOF ACH OF 7 SECTION WIDTH -SEE PLAN/MECH SCALE: NTS ---ffh��- SECTION 52.1 SCALE: NTS ��� w e0 •o••eu• s• p ••i .-LUENT��s••�/\ R DOX � \Cie 0- ` • • s. ,CL E s DATE SEPTEMBER 2010 MCVEIGH & MANGUM SCALE AS SHOWN ENGI N EERING•INC 9133 R.G. Skinner Pe.kway 1., FIonG 32256 DRAWN BY RMF Ph: (901)483-52M Pu: (9 )63-0 ee 633o em.u: Rl.ilc�4lucve;glNl.RBum.cmn Eug. ofRecoN: Tim W.Ovm Lisnx Ne.: 53'I35 DESIGNED BY TWO SHEET S2.1 SECTIONS AND DETAILS 50 OF 72 SHEETS J SEE SPECS FOR J TYPICAL RAIL FIBERGLASS CHANNEL, DETAIL I I I I I I I I J SEE PIAN 1 SEE 2/S2.2 FOR-��- SEE SPECS FOR J TYPICAL RAIL SEE 2/S2.2 FOR-��- SEE SPECS FOR r ALUMINUM TYPICAL RAIL FIBERGLASS CHANNEL, DETAIL I I I I I I I I I I I I I 1 I SEE PIAN 1 I I I I 1 I I I I I I I ALUMINUM CHANNEL. I 1 SEE PLAN I I CONIC CURB, SEE � I I I 1 I I I I DETAIL 3/S2.3 SEE DET 7/S2.1 I I I I I ` T/EX15T CONIC WA PROJECT SEE ME EXIST CONC WALL SEE DET 2/S2.2 FOR TYP RAIL DETAIL — — I) III I I I I III SEE SPECS FOR FIBERGLASS GRATING AND ME. 111 I SEE PLAN FOR BRACE. SECURE ./r SS BOLT. E 523 SECTION SCALE: NTS EXISTING WALL SEE SPECS FOR FIBERGLASS GRATING AND MESH SPLITER BOX FLOOR W/N4 O B' OC EW CENTERED IN SLAB WIDTH -SEE PLAN/MECH SECTION 52.3 SCALE: NTS ALUMINUM CHANNEL. SECURE TO COL ./ (2) r DIA SS BOLT$, SEE PLAN ALUMINUM COL, SEE PLAN. SECURE TO CONIC ./(2) 5/8" OIA B TS EPDXIED 6' DEEP ON r BA E PL. TER CONT % ALUM CHANNEL C4X2.50 ATTACH CHANNEL TO CONIC WALL W/ %'e EPDXY ANCHOR 'I EMBED 6' MIN INTO CONC WALL I 8' F CONIC BEAM W/8- i5 hP a 8 /3 TIES O 12' OC o TYP I I CONT /4 BAR W/ /4 BAR O 12'OC 11TOP h S O BOTT 5 SECTION 52.3 SCALE: NTS 2 SECTION 52.3 SCALE: NTS FLASH/SEAL ROOF TO WALL TRANSITION TO PREVENT WATER FLOW INTO COVERED AREA. -CONN TO EXIST TANK BY ALUM MFG 12 —�2 I SEE PLAN I I I I I I I I I I ALUM CHANNEL BY ALUM MFG SEE SPECS FOR r ALUMINUM ISSUED FOR BIDS FIBERGLASS CHANNEL, 1A' 11/4/2010 SEE PIAN 1 6' 6'TRENCH DEPTH VARIES ADDENDUM /2 CDNC BEAM FOR J O] J m g' 11/17/2010 C ID SPLITTER BOX, SEE DET 2/S2.2 "D U O O SEE DET 7/S2.1 � FOR TYP RAIL DETAIL PROJECT CONC WALL � -� SEE 2/52.2 FOR ® — TYPICAL RAIL // DETAIL —� I — — — — — — — — FLLE NO ---__ --__ � I�-- i 1 I I EXISTING a III III WALL I��yIy I I I I I SEE PLAN WROTH I > I I ��pp I I I I I ---- -SEE I ALUMINUM CHANNEL, — — — — — — — - PLAN I 52.3 SCALE: NT$ I I I SEE SPECS I I I SLOPE Li --------\C\ FOR I SEE SPECS FOR V-6- 0 FIBERGLASS I 1 FIBERGLASS �j GRATING AND i I I I A GRATING AND MESH., Z I MESHLl I I IgLATFRRM EL. I:��. I 52.3 SCALE: NTS 2 SECTION 52.3 SCALE: NTS FLASH/SEAL ROOF TO WALL TRANSITION TO PREVENT WATER FLOW INTO COVERED AREA. -CONN TO EXIST TANK BY ALUM MFG 12 —�2 I SEE PLAN I I I I I I I I I I ALUM CHANNEL BY ALUM MFG SEE SPECS FOR r ALUMINUM ALUM CHANNEL, FIBERGLASS CHANNEL, 1A' GRATING AND MESH SEE PIAN 1 6' 6'TRENCH DEPTH VARIES SEE PLAN CDNC BEAM FOR J O] J m g' FROM 4- TO .- C ID SPLITTER BOX, CONT T&SOTT & /5018' OC PERT DRILLED AND EPDXY ANGLES EA18ED 6' MIN INTO "D U O O SEE DET 7/S2.1 2 SECTION 52.3 SCALE: NTS FLASH/SEAL ROOF TO WALL TRANSITION TO PREVENT WATER FLOW INTO COVERED AREA. -CONN TO EXIST TANK BY ALUM MFG 12 —�2 I SEE PLAN I I I I I I I I I I ALUM CHANNEL BY ALUM MFG 3- COMPOSITE ALUM PANELS BY ALUM MFG IC SEE MECH DWGS FOR SEE SPECS FOR N ALUM CHANNEL, FIBERGLASS 2•-W 1A' GRATING AND MESH N N 6' 6'TRENCH DEPTH VARIES N 6' J O] J m g' FROM 4- TO .- C ID CONT T&SOTT & /5018' OC PERT DRILLED AND EPDXY ANGLES EA18ED 6' MIN INTO "D U O O (DEEPEST O SUMP) EPDXIED INTO EXISTING CONIC W Ll LLI CONC WALL SOPE ® C pM c N ELPLAN — to � 0 .O 0N ---__ --__ � WALL I a GRATING AND MESH � O SEC110H A -A > (� SECTION J I C SEE PLAN 52.3 SCALE: NT$ O SLOPE Li --------\C\ J SEE PLAN V-6- 0 `-SUMPIT BEYOND. SEE DETAIL 7/52.3 Z 6 SECTION 52.3 SCALE: NTS 3- COMPOSITE ALUM PANELS BY ALUM MFG IC SEE MECH DWGS FOR - N ALUM CHANNEL, M - SEE PLAN N N N ALUM Lh4xK.'x 0'-6' LG j N c7 N EA SIDE CHANNEL W/ 2-i'• S$ BOLTS CONNECTING J O] J m g' CONIC CURB W/2-/5 CHANNEL TO ANGLES h 2-11'e C ID CONT T&SOTT & /5018' OC PERT DRILLED AND EPDXY ANGLES EA18ED 6' MIN INTO "D U O O EPDXIED INTO EXISTING CONIC W Ll LLI CONC WALL 1Q N m ® C pM c N EXIST CONC — to � 0 .O 0N v WALL UD U Q r U0 N GRATING AND MESH � O SEC110H A -A � N (� SECTION 52.3 SCALE: NT$ O 3- COMPOSITE ALUM PANELS BY ALUM MFG IC SEE MECH DWGS FOR - Z PRE -ENG ALUM CANOPY ALL FRAMING h CONN TO BE BY ALUM MFC - SUBMIT SIGNED h SEALED Z OWLS FOR REVIEW k APPROVAL SEE MECH FOR PAVING $UMP REINF TO MA I SLAB RE BARS !lO NCL Lu U a Z Q ♦ �'�4i OdA�$i -Av J WV CL »t;4 DATE SEPTEMBER 2010 McVEIGH & MANGUM O E N G T N E E RI N G - I NC 3 a.G. smoeR P..I�mmY 1 kpnvilM R.— 1— 2236 U d -52D0 Pu (9M1636-6]]0 -d; E 6330 im mail�igMCVcighMkngwn .. g o(Rca,tl: Tim YI. OV.< :32]33 DESIGNED BY TWO SECTIONS AND DETAILS SEE SPECS FOR Q 52 OF 72 SHEETS FIBERGLASS < GRATING AND MESH F— CONC SLAB, SEE PLAN O SLOPE Li LL 1 SEE PLAN LL_ 0 Z v SLLJ C LLJ %tilt s1jM ' IS. > 6' �I✓IO� O . sy � !lO NCL I ALE: NTO a ♦ �'�4i OdA�$i -Av WV »t;4 DATE SEPTEMBER 2010 McVEIGH & MANGUM SCALE AS SHOWN E N G T N E E RI N G - I NC 3 a.G. smoeR P..I�mmY 1 kpnvilM R.— 1— 2236 DRAWN BY RMF d -52D0 Pu (9M1636-6]]0 -d; E 6330 im mail�igMCVcighMkngwn .. g o(Rca,tl: Tim YI. OV.< :32]33 DESIGNED BY TWO SECTIONS AND DETAILS SHEET S2.3 52 OF 72 SHEETS q��4wn�� r -av-.r W. DAVID LASSETTER PE/37971 REVISIONS CONFORME 12/16/10 PROJECT FILE NO C N N U N N [L w m h m C p cn c N _W`b0 O Cn NY N Lu U Z Q J EL O U J L F- IY O LL LL O H Z v Lu Lu 1 O CL 0- F- DATE Z1- DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-2 54 OF 72 SHEETS CONDUIT AND CABLE SCHEDULE CONDUIT NO. SIZE CONDUIT NO. SIZE COND. CABLE AWG TYPE VOLT FROM TO FOR NOTES P230 2.50 3 3/0 C001 1.50 37 14 THWN 600 MCC1 MAIN INST PANEL STATUS, CONTROL THWIN S001 1.50 4TSP 18 XLP 600 MCC1 MAIN INST PANEL ANALOG SIGNALS 600 1 MCC2 TURBO BLOWER 1 SH C230 1 0.75 7 14 THWIN 600 MCC2 C002 1.50 37 14 THWN 600 MCC2 MAIN INST PANEL STATUS, CONTROL TURBO BLOWER 1 VALVE S002 1.50 4TSP 18 XLP 600 MCC2 MAIN INST PANEL ANALOG SIGNALS STATUS, CONTROLS C233 0.75 5 14 THWN 600 TURBO BLOWER 1 LCP TURBO BLOWER 1 DIS VALVE STATUS C003 1.50 37 14 THWN 600 MCC3 MAIN INST PANEL STATUS, CONTROL 5003 1.50 4TSP 18 XLP 600 MCC3 MAIN INST PANEL ANALOG SIGNALS 3 3/0 THWN 600 MCC2 TURBO BLOWER 3 POWER P240 --- 1 2 C004 2-2" SOEA 14 THWN 600 MCC4 MAIN INST PANEL STATUS, CONTROL THWN 5004 2.00 BTSP 18 XLP 600 MCC4 MAIN INST PANEL ANALOG SIGNALS 600 MCC2 TURBO BLOWER 3 LCP STATUS, CONTROLS C241 0.75 9 14 THWN 600 TURBO BLOWER 3 LCP F005 2.00 6PR FO XLP --- MAIN LIFT STATION PANEL MAIN INST PANEL ETHERNET NETWORK FIBER OPTIC CABLE STATUS, CONTROLS C243 0.75 5 14 THWN 600 TURBO BLOWER 3 LCP TURBO BLOWER 3 DIS VALVE STATUS S006 1.00 CAT6 --- --- --- MAIN SWITCHBOARD MAIN INST PANEL ETHERNET NETWORK CAT6 CABLE -250 2.50 5007 1.00 CAT6 --- --- --- TURBO BLOWER MCP MAIN INST PANEL ETHERNET NETWORK CAT6 CABLE 2 THWN 600 MCC2 TURBO BLOWER 5 GROUND -250 --- 4 14 THWN 600 MCC2 TURBO BLOWER 5 SH C250 0.75 7 14 THWN 600 MCC2 TURBO BLOWER 5 LCP STATUS, CONTROLS C251 0.75 9 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER 5 VALVE STATUS, CONTROLS C252 0.75 9 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER MCP STATUS, CONTROLS C253 0.75 5 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER 5 DIS VALVE STATUS P320 1.50 6 8 THWN 600 MCC3 MH E4 POWER P320 --- 2 10 THWN 600 MCC3 MH E4 GROUND C320 1.50 22 14 THWN 600 MAIN INSTRUMENT PANEL MH E4 STATUS, CONTROLS P321 1.00 3 8 THWN 600 MH E4 FILTER 1 CONTROL PANEL POWER P321 --- 1 10 THWN 600 MH E4 FILTER 1 CONTROL PANEL GROUND C321 1.00 11 14 THWN 600 MH E4 FILTER 1 CONTROL PANEL CONTROLS P322 0.75 4 12 THWN 600 FlLTER 1 CONTROL PANEL FILTER 1 DRIVE MOTOR POWER, GROUND P323 0.75 4 12 THWN 600 FILTER 1 CONTROL PANEL FILTER 1 BACKWASH PUMP POWER, GROUND C324 0.75 9 14 THWN 600 FILTER 1 CONTROL PANEL FILTER 1 JUNCTION BOX CONTROLS P325 1 1.00 3 8 THWN 600 MH E4 FILTER 2 CONTROL PANEL POWER P325 --- 1 10 THWN 600 MH E4 FILTER 2 CONTROL PANEL GROUND C325 1.00 11 14 THWN 600 MH E4 FILTER 2 CONTROL PANEL CONTROLS P326 0.75 4 12 THWN 600 FILTER 2 CONTROL PANEL FILTER 2 DRIVE MOTOR POWER, GROUND P327 0.75 4 12 THWN 600 FILTER 2 CONTROL PANEL FILTER 2 BACKWASH PUMP POWER, GROUND C328 0.75 9 1 14 THWN 1 600 FILTER 2 CONTROL PANEL FILTER 2 JUNCTION BOX CONTROLS P330 2.00 3 2 THWN 600 MCC3 REUSE PUMP CONTROL PNL POWER P330 --- 1 4 THWN 600 MCC3 REUSE PUMP CONTROL PNL GROUND C330 1.00 11 14 THWN 600 MAIN INSTRUMENT PANEL REUSE PUMP CONTROL PNL STATUS, CONTROLS P331 1.50 3 8 THAN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 POWER P331 --- 1 10 1 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 GROUND P331 --- 4 14 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 TS, SH P332 1.50 3 1 8 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 POWER P332 --- 1 10 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 GROUND P332 --- 4 14 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 TS, SH q��4wn�� r -av-.r W. DAVID LASSETTER PE/37971 REVISIONS CONFORME 12/16/10 PROJECT FILE NO C N N U N N [L w m h m C p cn c N _W`b0 O Cn NY N Lu U Z Q J EL O U J L F- IY O LL LL O H Z v Lu Lu 1 O CL 0- F- DATE Z1- DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-2 54 OF 72 SHEETS CONDUIT AND CABLE SCHEDULE CONDUIT NO. SIZE COND. CABLE AWG TYPE VOLT FROM TO FOR NOTES P230 2.50 3 3/0 THWN 600 MCC2 TURBO BLOWER 1 POWER P230 --- 1 2 THWIN 600 MCC2 TURBO BLOWER 1 GROUND P230 --- 4 14 THWN 600 1 MCC2 TURBO BLOWER 1 SH C230 1 0.75 7 14 THWIN 600 MCC2 TURBO BLOWER 1 LCP STATUS, CONTROLS C231 1 0.75 9 14 THWN 600 TURBO BLOWER 1 LCP TURBO BLOWER 1 VALVE STATUS, CONTROLS C232 0.75 9 14 THWN 600 TURBO BLOWER 1 LCP TURBO BLOWER MCP STATUS, CONTROLS C233 0.75 5 14 THWN 600 TURBO BLOWER 1 LCP TURBO BLOWER 1 DIS VALVE STATUS P240 2.50 3 3/0 THWN 600 MCC2 TURBO BLOWER 3 POWER P240 --- 1 2 THWN 600 MCC2 TURBO BLOWER 3 GROUND P240 --- 4 14 THWN 600 MCC2 TURBO BLOWER 3 SH C240 1 0.75 7 14 THWN 600 MCC2 TURBO BLOWER 3 LCP STATUS, CONTROLS C241 0.75 9 14 THWN 600 TURBO BLOWER 3 LCP TURBO BLOWER 3 VALVE STATUS, CONTROLS C242 0.75 9 14 THWN 600 TURBO BLOWER 3 LCP TURBO BLOWER MCP STATUS, CONTROLS C243 0.75 5 14 THWN 600 TURBO BLOWER 3 LCP TURBO BLOWER 3 DIS VALVE STATUS -250 2.50 3 3/0 THWN 600 MCC2 TURBO BLOWER 5 POWER P250 --- 1 2 THWN 600 MCC2 TURBO BLOWER 5 GROUND -250 --- 4 14 THWN 600 MCC2 TURBO BLOWER 5 SH C250 0.75 7 14 THWN 600 MCC2 TURBO BLOWER 5 LCP STATUS, CONTROLS C251 0.75 9 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER 5 VALVE STATUS, CONTROLS C252 0.75 9 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER MCP STATUS, CONTROLS C253 0.75 5 14 THWN 600 TURBO BLOWER 5 LCP TURBO BLOWER 5 DIS VALVE STATUS P320 1.50 6 8 THWN 600 MCC3 MH E4 POWER P320 --- 2 10 THWN 600 MCC3 MH E4 GROUND C320 1.50 22 14 THWN 600 MAIN INSTRUMENT PANEL MH E4 STATUS, CONTROLS P321 1.00 3 8 THWN 600 MH E4 FILTER 1 CONTROL PANEL POWER P321 --- 1 10 THWN 600 MH E4 FILTER 1 CONTROL PANEL GROUND C321 1.00 11 14 THWN 600 MH E4 FILTER 1 CONTROL PANEL CONTROLS P322 0.75 4 12 THWN 600 FlLTER 1 CONTROL PANEL FILTER 1 DRIVE MOTOR POWER, GROUND P323 0.75 4 12 THWN 600 FILTER 1 CONTROL PANEL FILTER 1 BACKWASH PUMP POWER, GROUND C324 0.75 9 14 THWN 600 FILTER 1 CONTROL PANEL FILTER 1 JUNCTION BOX CONTROLS P325 1 1.00 3 8 THWN 600 MH E4 FILTER 2 CONTROL PANEL POWER P325 --- 1 10 THWN 600 MH E4 FILTER 2 CONTROL PANEL GROUND C325 1.00 11 14 THWN 600 MH E4 FILTER 2 CONTROL PANEL CONTROLS P326 0.75 4 12 THWN 600 FILTER 2 CONTROL PANEL FILTER 2 DRIVE MOTOR POWER, GROUND P327 0.75 4 12 THWN 600 FILTER 2 CONTROL PANEL FILTER 2 BACKWASH PUMP POWER, GROUND C328 0.75 9 1 14 THWN 1 600 FILTER 2 CONTROL PANEL FILTER 2 JUNCTION BOX CONTROLS P330 2.00 3 2 THWN 600 MCC3 REUSE PUMP CONTROL PNL POWER P330 --- 1 4 THWN 600 MCC3 REUSE PUMP CONTROL PNL GROUND C330 1.00 11 14 THWN 600 MAIN INSTRUMENT PANEL REUSE PUMP CONTROL PNL STATUS, CONTROLS P331 1.50 3 8 THAN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 POWER P331 --- 1 10 1 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 GROUND P331 --- 4 14 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 1 TS, SH P332 1.50 3 1 8 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 POWER P332 --- 1 10 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 GROUND P332 --- 4 14 THWN 600 REUSE PUMP CONTROL PNL REUSE PUMP 2 TS, SH q��4wn�� r -av-.r W. DAVID LASSETTER PE/37971 REVISIONS CONFORME 12/16/10 PROJECT FILE NO C N N U N N [L w m h m C p cn c N _W`b0 O Cn NY N Lu U Z Q J EL O U J L F- IY O LL LL O H Z v Lu Lu 1 O CL 0- F- DATE Z1- DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-2 54 OF 72 SHEETS JEA UG PRIMARY " JEA PAD MOUNTED SERVICE TRANSFORMER: 1500 KVA, 5.757, 480/277V, 3 PH SERVICE. MAXIMUM AIC: 31,414 AMPS SERVICE I It METERING ar- 6-4"C, 4EA #500 2-4`C, SPARE EXISTING MAIN SWITCHBOARD (CUTLER -HAMMER POW -R -LINE C) 3000 AMP, 480/277 VOLT, 3 PHASE, 4 WIRE, 100,000 AIC, SERVICE ENTRANCE RATED NOTES 1. THE SCADA SYSTEM INTEGRATOR SHALL EXPAND THE EXISTING PLANT SCADA SYSTEM TO MONITOR AND CONTROL PLANT ELECTRICAL POWER CONSUMPTION AND DEMAND. THE SCADA SYSTEM INTEGRATOR SHALL DEVELOP A SET OF HMI POWER MONITORING AND CONTROL SCREENS WITH ACCESS TO ALL OF THE POWER MONITORING PARAMETERS AVAILABLE FROM THE NEW SWITCHBOARD ELECTRONIC POWER METERING. 2. THE NEW SCADA SYSTEM HMI POWER MONITORING SCREENS SHALL ALLOW THE OPERATOR TO RECORD AND TREND KWH AND KW DEMAND, AND TO ASSIGN PEAK DEMAND ALARM AND LOAD SHED SETPOINTS. INDIVIDUAL LOAD SHED PARAMETERS (PRIORITY 1-4, MIN TIME, MAX TIME) SHALL BE INPUT FOR EACH PLANT LOAD CAPABLE OF BEING CONTROLLED BY THE SCADA SYSTEM. WHEN THE PEAK DEMAND LOAD SHED SET POINT HAS BEEN EXCEEDED FOR AN ADJUSTABLE TIME PERIOD, THE SCADA SYSTEM SHALL AUTOMATICALLY SEQUENTIALLY SHED LOAD (BEGINNING WITH PRIORITY 1) AS REQUIRED TO REDUCE THE TOTAL DEMAND BELOW THE LOAD SHED SETPOINT FOR AN ADJUSTABLE TIME PERIOD. 3. THE NEW SCADA SYSTEM HMI POWER MONITORING SCREENS SHALL PROVIDE DUPLICATE POWER MONITORING FOR THE TOTAL ELECTRICAL SERVICE AND FOR THE MAIN SWITCHBOARD EMERGENCY BUS, INCLUDING SEPARATE LOAD SHED SETPOINT DURING STANDBY POWER OPERATION. 6-4"C, 4EA #500 & tEA 114/OG I i 700 KW 1601 1100 STANDBY GENERATOR #3 29�6&. / v-1-14 W. DAVID LASSETTER PE#37971 SINGLE LINE DIAGRAM - MAIN SWITCHBOARD REVISIONS CONFORMED 12/16/10 I FILE NO N 4 J> M N C J m a = C w - 1L .. c W G .N o N O m m N U Q c N Ll U � W U Z Q J CL L O J C0 t— O M. 1 LL }0 F- F•' Cell Z V W W O w 0 - CL F— ►9 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-4 56 OF 72 SHEETS NORMAL BUS (3000 AMP, 480 VOLTS, 3 PHASE, 3 WIRE, 100,000 A.I.C.) EMERGENCY BUS (3000 AMP, 480 VOLTS, 3 PHASE, 3 WIRE, 100,000 A.I.C.) T I I > g0 ) pp � } DELAYED TRANSITION AUTOMATIC TRANSFER 120 > 164Q0 ) 11200 ) 800 } � � y l) J J 400 `} 70 1 SW TCH SPO TYPICAL PROVIDE NEW SWITCHBOARD DISTRIBUTION MOUNTED SURGE PROTECTION (UL 1448 3RD VS 3WkA 45 KVA DRY TRANSFORMER 3000 \ 2000 /1 ? E I 300kA 1 2 EDITION LISTED, UL 96A COMPLIANT, MODULAR CONSTRUCTION, MINIMUM 300kA PER PHASE) TYPICAL PROVIDE NEW SWITCHBOARD ELECTRONIC WITH ETHERNET PORT AND MODBUS TOP NETWORK CONNECTION TO THE EXISTING SCADA SYSTEM (POWER MEASUREMENT ION 7350 -EO) 3400 4P j V KW A AS O " I I I I PROVIDE NEW FEEDER BREAKERWITHIN THE EXISTING SWITCHBOARD DISTRIBUTION SECTION.METERING P400 __-p PANEL 14 480-240/120V 3 PHASE, 4 WIRE SWITCHBOARD MAIN BREAKER SWITCHBOARD SURGE MCC1 METERING PROTECTION SPACE SPACE SPACE ( AUTOMATIC TRANSFER SWITCH MCC2 MCC3 SPARE SPARE NEW MCC4 LIGHTING PANEL NOTES 1. THE SCADA SYSTEM INTEGRATOR SHALL EXPAND THE EXISTING PLANT SCADA SYSTEM TO MONITOR AND CONTROL PLANT ELECTRICAL POWER CONSUMPTION AND DEMAND. THE SCADA SYSTEM INTEGRATOR SHALL DEVELOP A SET OF HMI POWER MONITORING AND CONTROL SCREENS WITH ACCESS TO ALL OF THE POWER MONITORING PARAMETERS AVAILABLE FROM THE NEW SWITCHBOARD ELECTRONIC POWER METERING. 2. THE NEW SCADA SYSTEM HMI POWER MONITORING SCREENS SHALL ALLOW THE OPERATOR TO RECORD AND TREND KWH AND KW DEMAND, AND TO ASSIGN PEAK DEMAND ALARM AND LOAD SHED SETPOINTS. INDIVIDUAL LOAD SHED PARAMETERS (PRIORITY 1-4, MIN TIME, MAX TIME) SHALL BE INPUT FOR EACH PLANT LOAD CAPABLE OF BEING CONTROLLED BY THE SCADA SYSTEM. WHEN THE PEAK DEMAND LOAD SHED SET POINT HAS BEEN EXCEEDED FOR AN ADJUSTABLE TIME PERIOD, THE SCADA SYSTEM SHALL AUTOMATICALLY SEQUENTIALLY SHED LOAD (BEGINNING WITH PRIORITY 1) AS REQUIRED TO REDUCE THE TOTAL DEMAND BELOW THE LOAD SHED SETPOINT FOR AN ADJUSTABLE TIME PERIOD. 3. THE NEW SCADA SYSTEM HMI POWER MONITORING SCREENS SHALL PROVIDE DUPLICATE POWER MONITORING FOR THE TOTAL ELECTRICAL SERVICE AND FOR THE MAIN SWITCHBOARD EMERGENCY BUS, INCLUDING SEPARATE LOAD SHED SETPOINT DURING STANDBY POWER OPERATION. 6-4"C, 4EA #500 & tEA 114/OG I i 700 KW 1601 1100 STANDBY GENERATOR #3 29�6&. / v-1-14 W. DAVID LASSETTER PE#37971 SINGLE LINE DIAGRAM - MAIN SWITCHBOARD REVISIONS CONFORMED 12/16/10 I FILE NO N 4 J> M N C J m a = C w - 1L .. c W G .N o N O m m N U Q c N Ll U � W U Z Q J CL L O J C0 t— O M. 1 LL }0 F- F•' Cell Z V W W O w 0 - CL F— ►9 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-4 56 OF 72 SHEETS J FROM MAIN SWITCHBOARD 4-4'C, 3EA #500, IEA #4/DG i za • MCC2 POWER MAIN LUSS METERING so TVSS SURGE PROTECTION EXISTING CUTLER HAMMER FREEDOM 2100 MOTOR CONTROL CENTER "MCC2" (1600 AMP, 480 VOLT, 3 PH, 3W, 65,000 AIC) 100 mr-p- 20 20 3 3 100 100 �. LC LC FVNR FVNR FVNR FVNR R 3P2a JR 3P20 A SIZE i ASIZE 1 R SIZE 3 R SIZE 3 G6 G G GH O A PB PB H 0 A EL 0 A 4 4 TASK SECURITY No.1 No.2 No.t No.2 HIGH MAST SITE LIGHTING SECONDARY CLARIFIERS RAS PUMPS NOTES:- 1. OTES:1. FOR EACH NEW TURBO PLANT AERATION BLOWER, REMOVE THE COMPLETE EXISTING AUTO -TRANSFORMER TWE REDUCED VOTAGE MOTOR STARTER UNITS FROM THE MCC AND PROVIDE COMPLETE NEW SOLID STATE REDUCED VOLTAGE SOFT START MOTOR STARTER UNITS WITHIN THE MCC. 2. FOR EACH EXISTING EFFLUENT PUMP PROVIDE REMOTE CONTROL FROM THE SCADA SYSTEM INCLUDING NEW MCC MOUNTED INTERPOSING RELAYS INTERCONNECTED TO THE EXISTING MOTOR STARTERS TO PROVIDE 'FORCE STOP', 'FORCE LOW SPEED' AND 'FORCE HIGH SPEED' CONTROL 3. REPLACE THE EXISTING EFFLUENT PUMP AUTOMATIC ALTERNATOR AND LEAD PUMP SELECTOR SWITCH LOCATED IN THE MAIN INSTRUMENTATION PANEL, TO RESTORE LEAD PUMP AUTOMATIC ALTERNATION. 4. REMOVE AND REPLACE THE EXISTING HIGH MAST LIGHTING SYSTEMS FOR EACH HIGH MAST LIGHT POLE (THREE POLES), INCLUDING COMPLETE NEW TOP LATCHING LOWER DEVICE, HEADFRAME, RING ASSEMBLY. LUMINAIRE MOUNTING ARMS, STAINLESS STEEL HOIST CABLES, TWO CIRCUIT 480 VOLT POWER CABLES, AND TWO CIRCUIT ENCLOSED CIRCUIT BREAKERS FOR EACH POLE REPLACE THE EXISTING HIGH MAST LUMINAIRES (SIX PER POLE) WITH NEW MATCHING LUMINAIRES (HOLOPHANE HMST400HP48APS). ALL NEW EQUIPMENT SHALL BE COMPATIBLE WITH THE EXISTING POLES AND SHALL MAINTAIN THE EXISTING WAND LOAD RATINGS PROVIDE ONE NEW PORTABLE WINCH AND POWER UNIT INCLUDING STEP DOWN TRANSFORMER. 5. PROVIDE DN/OFF/AUTO REMOTE CONTROL OF EACH HIGH MAST LIGHTING CIRCUIT FROM 7HE SCADA SYSTEM, INCLUDING PHOTO -CELL AUTOMATIC CONTROL AND 14 DAY/OAY OF WEEK/TIME OF DAY AUTOMATIC CONTROL NSA •\ Oj 400 l/ SSRV A SIZE 5 R G A R G 400 : / O A R G W40ZO:/ O — C230 P230 0240 P240 C250 125 LCP 125 LCP 125 No.1 No.3 No.5 NEW TURBO PLANT AERATION BLOWERS - TYPICAL NEW TURBO BLOWER LOCAL CONTROL PANEL kir mcp- 1M �1 100 �)15�! FVNR FVNR FVNR I SIZE 3 C SIZE 3 G SIZE 1 gOA H O A 30 30 3 No.1 No.2 No.1 WAS PUMPS CL2 INDUCTOR Wcp � 50 •\ l} � ! 1} 1 1} I 2S2W R SIZE 4 G I 2S2W R SIZE 4 j G 2S2W R SIZE 4 G FVNR G 512E 1 �.._� R G '' SI H L O A O2 H L 0 A OZ H L 0 A O2 H 0 A HE O A t i I 4O 40 40 No.t No.2 No.3 No.t No.2 EFFLUENT PUMPS S02 INDUCTORS W. DAVID LASSETTER PE/37971 112/16/10 I FILE NO P. CL 3 1 3 DATE OCT, 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-6 58 OF 72 SHEETS I FUSE CPT MANUAL DISCONNECT FUSE CPT MANUAL DISCONNECT 120VAC SPEED SAFE OFF POT OFF TSTAT HAND AUTO SPEED - -0 - - XOO MOTOR - - M OPERATED SIGNAL -- MOTOR PLC 4-2OMA - - WINDING 1 START OlLe ISOLATOR -I F- M RUN O-O0X - - M RUN RUN R M START OFF qLO-CAL G M CR I I -------------------------- HOA M a WINDING PLC INPUT PLC INPUT PLC INPUT 'RUNNING' 'AUTO MODE' "FAIL' TYPICAL AERATION TANK MIXER CONTROL WIRING DIAGRAM LOCAL TYPICAL VALVE MANUAL DISCONNECT MOTOR OPERATOR SPEED SWITCH - POT a SPEED - -0 - - MOTOR - - M OPERATED SIGNAL -- - ' VALVE 4-2OMA - - SPEED SIGNAL ISOLATOR --'� MCP INPUT RUN •VALVE OPEN' - - LCP RUN --� MCP INPUT TSTAT START VALVE CLOSED' qLO-CAL --�--,� ------ CR MOTOR MCP OUTPUI t T JJ LLL•IN _ PUT SIGNAL OUTPUT SIGNAL 4-2OMA 4-20MA FUSE CPT II 12OVAIC II CR SSRV RESET SSRV FAULT INVERTER DUTY MOTOR MCP NEMA MGI SECTION IV OC PART 31 (160OV) /T\ n - ���V13X VFD WTH i0- --0 INPUT UNE i 01 ACTOR ANDTPUT FILTER o - WD CABLE CPT 12OV II CR OC RUN SAFE OFF OFF TSTAT HAND AUTO XOO MOTOR WINDING START CR VFD 1 OOX CR OC I -I H MANUAL SPEED FLT - POT SPEED SPEED AT CONTROL SIGNAL -- - INPUT 4-2OMA - - SPEED SIGNAL ISOLATOR RUN M SAFE LCP RUN OFF TSTAT START --�--,� ------ CR MOTOR WINDING FLT FAULT A M RUN R M STOP G M X700 WATTS 1 ---------------------------J M FLT -�-d f -�-A 1-4 LCP INPUT LCP INPUT 'RUNNING' 'SSRV FAULT' TYPICAL TURBO BLOWER MOTOR STARTER CONTROL WIRING DIAGRAM INVERTER DUTY MOTOR MCP NEMA MGI SECTION IV OC PART 31 (160OV) /T\ n - ���V13X VFD WTH i0- --0 INPUT UNE i 01 ACTOR ANDTPUT FILTER o - WD CABLE CPT 12OV II CR OC RUN SAFE OFF OFF TSTAT HAND AUTO XOO MOTOR WINDING START CR VFD 1 OOX CR OC I -I H FLT A RUN RUN ii R RUN OFF G SF RESET MOISTURE j- - SF SEAL FAIL REIAY SENSOR o- - A SUBMERSIBLE PUMP MOISTURE DETECTION SEAL FAIL RELAY, FURNISHED BY THE PUMP SUPPLIER, AND INSTALLED IN THE MCC BY THE CONTRACTOR. HOA �UFLT SF � PLC INPUT PLC INPUT PLC INPUT PLC INPUT 'RUNNING' "AUTOMODE" 'VFD FAULT' 'SEAL FAIL' TYPICAL AERATION TANK RECIRCULATION PUMP CONTROL WIRING DIAGRAM W. DAVID LASSETTER PE/37971 REVISIONS CONFORMED 12/16/10 PROJECT FILE NO N N N J ; M N 0] C a) li c W N uJ m IQ C N p fA N N UQ�m N � o W W Z Q CL A :E O U J <Q G H f� O 0 LL I o LL- Q H Lu V L W O w a_ —IL OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-9 61 OF 72 SHEETS MANUAL SPEED - POT SPEED SPEED OUTPUT CONTROL SIGNAL -- - INPUT 4-2OMA - - 4-20MA SIGNAL ISOLATOR RUN RUN FAULT r� FLT A RUN RUN ii R RUN OFF G SF RESET MOISTURE j- - SF SEAL FAIL REIAY SENSOR o- - A SUBMERSIBLE PUMP MOISTURE DETECTION SEAL FAIL RELAY, FURNISHED BY THE PUMP SUPPLIER, AND INSTALLED IN THE MCC BY THE CONTRACTOR. HOA �UFLT SF � PLC INPUT PLC INPUT PLC INPUT PLC INPUT 'RUNNING' "AUTOMODE" 'VFD FAULT' 'SEAL FAIL' TYPICAL AERATION TANK RECIRCULATION PUMP CONTROL WIRING DIAGRAM W. DAVID LASSETTER PE/37971 REVISIONS CONFORMED 12/16/10 PROJECT FILE NO N N N J ; M N 0] C a) li c W N uJ m IQ C N p fA N N UQ�m N � o W W Z Q CL A :E O U J <Q G H f� O 0 LL I o LL- Q H Lu V L W O w a_ —IL OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-9 61 OF 72 SHEETS MAIN HEADER BLOW -OFF VALVE T PT PROCESS AIR FROM AERATION BLOWERS HS LEGEND NEW TURBO LCP BLOWER N0.1 I P&ID SIGNAL DESIGNATIONS ACM I NEW TURBO LCP I BLOWER NO.3 I 2C I ...... _. -0 I I I NEW TURBO LCP I I XY FIELD MOUNTED ff INSTRUMENT XY PANEL MOUNTED INSTRUMENT BLOWER NO.5 1 I I DISCRETE OUTPUT SIGNAL ANALOG INPUT SIGNAL ANALOG OUTPUT SIGNAL I I I I D DIFFERENTIAL ------ ------------- NETWORK COMMUNICATIONS VOLTAGE ------ ------ --------------- F FLOW I I 480V AERATION ZONE D.O. CONTROLLER (TYPICAL OF 8) DIGESTER LEVEL PID ------+------- PID CONTROLLER H HAND (FUTURE) I AERATION ZONE FLOW CONTROLLER (TYPICAL OF 8) I I DIGESTER FLOW PID –._._.+._._._. PID CONTROLLER J POWER (FUTURE) I K TIME I MAIN HEADER PRESSURE PID L LEVEL CONTROLLER r-------------- CP ---- -------i DISSOLVED OXYGEN I I TRANSMITTER r-- I �-'-(-'-'� I I AIT L FE 4-2 ZI HS HS ZT 0�0 AE °�/° L/R R � HEI �] FLOW CONTROL FLOW METER AERATION ZONE VALVE THERMAL 4-2 V-4-2 DISPERSION r --- CP ---- -------i DISSOLVED OXYGEN I I TRANSMITTER r-- I--I-'-'� I 1 AIT 480V FlT 4-1 ZI�/CL�/R AE ° FE 4-1 4-1 E �] I FLOWCONTROL AERATION ZONE VALVE 4-1 V-4-1 r----------- +--------------� DISSOLVED OXYGEN 1 TRANSMITTER I FIT 480V AIT 3-2 M ZSH ZSL ZC ZT HS HS ZI 3-2 3--2 L/A o/s/c 3-2 FE AE IEI FLOW METER FLOW CONTRA THERMAL VALVE DISPERSION V-3-2 AERATION ZONE 1 } 3-2 r----------- + - -----� DISSOLVED OXYGEN I I F- I-'- 1-- i TRANSMITTER I FlT 480V AIT 3-1 M ZSH ZSL ZC 2T HS HS ZI 3-1 FE L/R o/s/c AE 3-1 3-1 E D-�'�ZIHJ- FLOW CONTROL VALVE V-3-1 AERATION ZONE 3-1 FLOW METER FLOW METER THERMAL THERMAL DISPERSION DISPERSION INSTRUMENTATION LEGEND SUCCEEDING LETTERS P&ID SIGNAL DESIGNATIONS ACM ANALOG CONTROL MODULE A ...... _. -0 DISCRETE INPUT SIGNAL XY FIELD MOUNTED ff INSTRUMENT XY PANEL MOUNTED INSTRUMENT / XY I BACK OF PANEL 1\ / MOUNTED DEVICE S41 Q � _- 9 - --- DISCRETE OUTPUT SIGNAL ANALOG INPUT SIGNAL ANALOG OUTPUT SIGNAL CONTROLLER D DIFFERENTIAL r- --------♦ NETWORK COMMUNICATIONS "Xy" FIRST LETTER SUCCEEDING LETTERS ACM ANALOG CONTROL MODULE A ANALYTICAL ALARM B BURNER, COMBUSTION I C r-- CONTROLLER D DIFFERENTIAL I--j–'–•� I E VOLTAGE SENSOR, PRIMARY ELEMENT F FLOW HAND–OFF–AUTOMATIC SELECTOR SWITCH G INSTRUMENTATION CONTROL PANEL GLASS, VIEWING DEVICE H HAND HIGH I CURRENT INDICATE J POWER L K TIME CONTROL STATION L LEVEL LOW M PH MEASUREMENT MIDDLE, INTERMEDIATE N RIM RADIO INTERFACE MODULE 0 FLOW CONTROL FLOW METER ORIFICE P PRESSURE, VACUUM POINT 0 QUANTITY DISPERSION R RADIATION RECORDER S SPEED, FREQUENCY SNATCH T TEMPERATURE TRANSMITTER U MULTIVARIABLE MULTIFUCTION V VIBRATION VALVE, DAMPER, LOUVER W WEIGHT, FORCE WELL X I AIT Y EVENT RELAY, COMPUTE, CONVERTER Z POSITION ACTUATOR "XYZ" MISCELLANEOUS ABBREVIATIONS ACM ANALOG CONTROL MODULE Al I DISSOLVED OXYGEN ANALOG MONITOR MODULE AO I TRANSMITTER r-- DCM DIGITAL CONTROL MODULE DI I--j–'–•� I DO DIGITAL OUTPUT SIGNAL FOR FORWARD–OFF–REVERSE SELECTOR SVATCH HOA HAND–OFF–AUTOMATIC SELECTOR SWITCH ICP INSTRUMENTATION CONTROL PANEL NTU NEPHELOMETRIC TURBIDITY UNITS HS HStnL MOTOR CONTROL CENTER MIP MAIN INSTRUMENTATION PANEL o/s/c L' MIXED LIQUOR SUSPENDED SOLIDS 02 L 01 OPERATOR INTERFACE PUMP CONTROL MODULE PLC PROGRAMMABLE LOGIC CONTROLLER MODULE pH PH MEASUREMENT PSM IEI RIM RADIO INTERFACE MODULE RTU FLOW CONTROL FLOW METER S/C SIGNAL CONVERTER VALVE THERMAL AERATION ZONE V-2-2 DISPERSION 2-2 r-------------- CP ----------� DISSOLVED OXYGEN I I TRANSMITTER r-- I--j-'-'� I AIT I 2-1ml9linL AE 2-1 "XYZ" MISCELLANEOUS ABBREVIATIONS ACM ANALOG CONTROL MODULE Al ANALOG INPUT SIGNAL AMM ANALOG MONITOR MODULE AO ANALOG OUTPUT SIGNAL CL I CHLORINE RESIDUAL MEASUREMENT DCM DIGITAL CONTROL MODULE DI DIGITAL INPUT SIGNAL DO DIGITAL OUTPUT SIGNAL FOR FORWARD–OFF–REVERSE SELECTOR SVATCH HOA HAND–OFF–AUTOMATIC SELECTOR SWITCH ICP INSTRUMENTATION CONTROL PANEL NTU NEPHELOMETRIC TURBIDITY UNITS MCC MOTOR CONTROL CENTER MIP MAIN INSTRUMENTATION PANEL MLSS MIXED LIQUOR SUSPENDED SOLIDS 02 DISSOLVED OXYGEN MEASUREMENT 01 OPERATOR INTERFACE PCM PUMP CONTROL MODULE PLC PROGRAMMABLE LOGIC CONTROLLER MODULE pH PH MEASUREMENT PSM POWER SUPPLY MODULE RIM RADIO INTERFACE MODULE RTU REMOTE TELEMETRY UNIT S/C SIGNAL CONVERTER S/I SIGNAL ISOLATOR VFD VARIABLE FREQUENCY DRIVE ----------------------------- ------------- DISSOLVED OXYGEN i I r. _. _I _. _. _ _ TRANSMITTER I 480V i i i r FLOW METER FLOW CONTROL THERMAL VALVE DISPERSION V-1-2 AERATION ZONE {} 1-2 r----------- +-------- -� DISSOLVED OXYGEN I I TRANSMITTER I FlT 480V AIT 1-1 M ZSH ZSL ZC ZT HS HS ZI 1-1 FE L/R 0/S/C AE 1-1 1-1 E d FLOW CONTROL FLOW METER FLOW METER FLOW CONTROL fA AERATION ZONE VALVE THERMAL THERMAL VALVE V-2-1 DISPERSION DISPERSION V-1-1 AERATION ZONE 2-1 1-1 W. DAVID LASSETTER PE/37971 CONFORMED 12/16/10 I FILE NO C N N U N N J 00 V) J m w C) to o W a C p � c N y v; 0 V 0 y N W L) LL) U z Q J CL L 0 0 t O LL z LL) W C� L a. I— ►A DATE OCT, 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-11 63 OF 72 SHEETS PLOT EXISTING DIGITAL INPUT SIGNALS DI _TAG DESCRIPTION O1 AUTO INFLUENT SCREEN 02 RUN INFLUENT SCREEN 03 ALARM INFLUENT SCREEN 04 AUTO SCUM PUMP 1 05 RUN SCUM PUMP 1 06 AUTO SCUM PUMP 2 07 RUN SCUM PUMP 2 08 FAULT SECONDARY CLARIFIER 1 09 RUN SECONDARY CLARIFIER 1 10 FAULT SECONDARY CLARIFIER 2 11 RUN SECONDARY CLARIFIER 2 12 FAULT SECONDARY CLARIFIER 3 13 RUN SECONDARY CLARIFIER 3 14 AUTO RAS PUMP 1 i5 RUN RAS PUMP 1 16 AUTO RAS PUMP 2 17 RUN RAS PUMP 2 18 AUTO WAS PUMP 1 19 RUN WAS PUMP 1 20 AUTO WAS PUMP 2 21 RUN WAS PUMP 2 22 AUTO EFFLUENT PUMP 1 23 LOW EFFLUENT PUMP 1 24 HIGH EFFLUENT PUMP 1 25 AUTO EFFLUENT PUMP 2 26 LOW EFFLUENT PUMP 2 27 HIGH EFFLUENT PUMP 2 26 AUTO EFFLUENT PUMP 3 29 LOW EFFLUENT PUMP 3 30 HIGH EFFLUENT PUMP 3 31 AUTO EFFLUENT PUMP 4 32 LOW EFFLUENT PUMP 4 33 HIGH EFFLUENT PUMP 4 34 AUTO CL2 INDUCTOR 35 RUN CL2 INDUCTOR 36 AUTO S02 INDUCTOR 1 37 RUN S02 INDUCTOR 1 38 AUTO S02 INDUCTOR 2 39 RUN S02 INDUCTOR 2 40 AUTO BLOWER 1 41 RUN BLOWER 1 43 AUTO BLOWER 3 43 RUN BLOWER 3 44 AUTO BLOWER 5 45 RUN BLOWER 5 46 AUTO BLOWER 7 47 RUN BLOWER 7 46 AUTO BLOWER 2 49 RUN BLOWER 2 50 AUTO BLOWER 4 51 RUN BLOWER 4 52 AUTO BLOWER 6 53 RUN BLOWER 6 54 AUTO BLOWER 8 55 RUN BLOWER 8 56 SPARE SPARE 57 ALARM POWER SYSTEM FAIL 58 ALARM GENERATOR FAIL 59 ALARM SLOWER CONTROL FAIL 60 ALARM CLARIFIER 1 HIGH TORQUE 51 ALARM CLARIFIER 2 HIGH TORQUE 62 ALARM CLARIFIER 3 HIGH TORQUE 63 ALARM RAS/WAS WET WELL HIGH 64 ALARM RAS/WAS WET WELL LOW 65 ALARM EFFLUENT WET WELL HIGH 66 ALARM SLUDGE TANK LEVEL HIGH 67 ALARM CHLORINE LEAK ALARM 68 ALARM CHLORINE SUPPLY LOW 69 ALARM S02 LEAK ALARM 70 ALARM S02 SUPPLY LOW 71 ALARM MAIN PANEL ALARM 72 SPARE 19 73 RUN INFLUENT PUMP 1 74 FAIL INFLUENT PUMP 1 75 RUN INFLUENT PUMP 2 76 FAIL INFLUENT PUMP 2 77 RUN INFLUENT PUMP 3 78 FAIL INFLUENT PUMP 3 79 ALARM MASTER LIFT STATION HIGH 80 SPARE WAS PUMP 2 81 ALARM EFFLUENT PUMP i FAIL 82 ALARM EFFLUENT PUMP 2 FAIL 83 ALARM EFFLUENT PUMP 3 FAIL 84 ALARM BLOWER 1 FAIL 85 ALARM BLOWER 2 FAIL 86 ALARM BLOWER 3 FAIL 87 ALARM BLOWER 4 FAIL 88 ALARM BLOWER 5 FAIL 89 ALARM CL2 INDUCTOR FAIL 90 ALARM S02 INDUCTOR 1 FAIL 91 ALARM SO2 INDLUTDR 2 FAIL 92 ALARM RAS PUMP 1 FAIL 93 ALARM RAS PUMP 2 FAIL 94 ALARM WAS PUMP 1 FAIL 95 ALARM WAS PUMP 2 FAIL 96 SPARE 24 97 SPARE 24 98 SPARE LOW HIGH 99 SPARE AUTO 100 SPARE SPARE SPARE 101 SPARE AER TK 1 MIXER 2 START/STOP 102 SPARE EFFLUENT PUMP 3 103 SPARE AER TK 2 MIXER 4 AER TK 2 MIXER 104 SPARE REVISIONS CONFORME 12/16/10 FILE NO Lu Z Q J C� L O U J G t— 0 t2 LL LTJ O Ex CIL L F- 3 3 LLC 0 U UAIL OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-13 65 OF 72 SHEETS PLC1 PLC1 NEW DIGITAL INPUT SIGNALS NEW DIGITAL INPUT SIGNALS PLC!EXIST NG DIGITAL OUTPUT SIGNALS PLC7IGITAL CI TAG DESCRIPTION DI TAG DESCRIPTION EXISTING D OUTPUT SIGNALS DO TAG pESCRlPTiON O1 02 STATUS STATUS ATS IN NORMAL 998 7 FAIL RECIRCULATION PUMP 3 DO TAG DESCRIPTION 03 STATUS AIS IN EMERGENCY EMERGENCY AVAILABLE 99 �� RECIRCULATION PUMP 4 O1 02 EFFLUENT PUMP SPEED CHANGE SPARE Oi EFFLUENT PUMP SPEED CHANGE 04 AUTO SCUM PUMP i RUN 100 FAIL RECIRCULATION PUMP 4 RECIRCULATION PUMP 4 03 SPARE 02 EFFLUENT FORCE MAIN LOW PRESSURE OS 06 RUN SCUM PUMP 1 101 AUTO AER 1K 1 MIXER 1 04 SPARE 03 EFFLUENT PUMP 1 FORCE HIGH OJ AUTO RUN SCUM PUMP 2 102 RUN AER TK 1 MIXER 1 05 SPARE 04 05 EFFLUENT PUMP 1 FORCE LOW 08 FAULT SCUM PUMP 2 103 FAIL AER TK 1 MIXER 1 06 SPARE 06 EFFLUENT PUMP 1 FORCE OFF EFFLUENT SECONDARY CLARIFIER f 104 AUTO AER TK 1 MIXER 2 07 SPARE PUMP 2 FORCE HIGH07 09 10 RUN SECONDARY CLARIFIER 1 105 RUN AER TK 1 MIXER 2 08 SPARE 08 EFFLUENT PUMP 2 FORCE LOW EFFLUENT PUMP 2 FORCE OFF ti FAULT RUN SECONDARY CLARIFIER 2 SECONDARY CLARIFIER 2 106 107 FAIL AER TK 1 MIXER 2 OS 10 SPARE SPARE 09 EFFLUENT PUMP 3 FORCE HIGH 12 FAULT SECONDARY CLARIFIER 3 108 AUTO RUN AER TK 1 MIXER 3 AER TK 1 MIXER 3 12 SPARE 10 EFFLUENT PUMP 3 FORCE LOW 13 14 RUN SECONDARY CLARIFIER 3 109 FAIL AER TK 1 MIXER 3 12 SPARE 11 EFFLUENT PUMP 3 FORCE OFF 15 AUTO RUN RAS PUMP 1 110 AUTO AER TK 1 MIXER 4 13 SPARE 12 13 AER TK 1 MIXER 1 START/STOP AER 76 AU70 RAS PUMP 1 RAS PUMP 2 111 RUN AER TK 1 MIXER 4 14 15 SPARE 14 TK 1 MIXER 2 START/STOP AER TK 1 MIXER 3 START/STOP 112 FAIL AER TK 1 MIXER 4 fS SPARE SPARE 15 AER TK 1 MIXER 4 START/STOP 17 18 RUN AUTO RAS PUMP 2 113 AUTO AER TK 2 MIXER 1 16 AER TK 1 MIXER 1 START/STOP 19 RUN WAS PUMP 1 WAS PUMP 7 114 115 RUN FAIL AER TK 2 MIXER 1 17 18 SPARE SPARE 17 AER TK 1 MIXER 2 START/STOP 20 AUTO WAS PUMP 2 118 AUTO AER TK 2 MIXER 1 AER TK 19 SPARE 18 AER TK 1 MIXER 3 START/STOP 21 RUN WAS PUMP 2 117 RUN 2 MIXER 2 AER TK 20 SPARE 19 AER TK 1 MIXER 4 START/STOP 22 AUTO EFFLUENT PUMP 1 118 FAIL 2 MIXER 2 AER TK 2 MIXER 2 2i SPARE 20 AER TK 1 MIXER 1 START/STOP 23 24 LOW HIGH EFFLUENT PUMP 1 119 AUTO AER TK 2 MIXER 3 22 SPARE 21 22 AER TK 1 MIXER 2 START/STOP EFFLUENT PUMP i 120 RUN AER TK 2 MIXER 3 23 SPARE 23 AER TK 1 MIXER 3 START/STOP AER TK 25 26 AUTO EFFLUENT PUMP 2 121 FAIL AER TK 2 MIXER 3 24 SPARE 24 1 MIXER 4 START/STOP AER TK 1 MIXER 1 START/STOP 27 LOW HIGH EFFLUENT PUMP 2 EFFLUENT PUMP 2 1ZZ 123 AUTO AER TK 2 MIXER4 25 26 SPARE SPARE 25 AER TK 1 MIXER 2 START/STOP 28 AUTO EFFLUENT PUMP 3 124 RUN FAIL AER TK 2 MIXER 4 AER TK 2 MIXER 27 SPARE 26 AER TK 1 MIXER 3 START/STOP 29 30 LOW HIGH EFFLUENT PUMP 3 EFFLUENT PUMP 3 125 STD 4 AER TK 3 MIXER i 28 29 SPARE SPARE 27 28 AER TK 7 MIXER 4 START/STOP RECIRCULATION PUMP 1 START/STOP 31 AUTO EFFLUENT PUMP 4 126 127 RUN FAIL AER TK 3 MIXER 1 30 SPARE 29 RECIRCULATION PUMP 2 START/STOP 32 LOW EFFLUENT PUMP 4 128 AUTO AER TK 3 MIXER 1 AER TK 3 MIXER 2 31 SPARE 30 RECIRCULATION PUMP 3 START/STOP 32 SPARE 31 RECIRCULATION PUMP 4 START/STOP 33 34 HIGH AUTO EFFLUENT PUMP 4 129 RUN AER TK 3 MIXER 2 32 BLOWER 2 START/STOP 35 RUN CL2 INDUCTOR CL2 INDUCTOR 130 131 FAIL AER TK 3 MIXER 2 33 BLOWER 4 START/STOP 36 AUTO S02 INDUCTOR 1 132 AUTO RUN AER TK 3 MIXER 3 34 SLUDGE BLOWER 1 START/STOP 37 RUN S02 INDUCTOR 1 133 FAIL AER 7K 3 MIXER 3 35 SLUDGE BLOWER 2 START/STOP 38 AUTO S02 INDUCTOR 2 134 AUTO AER TK 3 MIXER 3 AER TK 3 MIXER 4 36 HIGH MAST SECURITY ON/OFF 39 40 RUN AUTO S02 INDUCTOR 2 FILTER 1 135 RUN AER TK 3 MIXER 4 37 38 HIGH MAST TASK ON/OFF CARBON FEED PUMP 1 START/STOP 136 FAIL AER TX 3 MIXER 4 39 CARBON FEED PUMP 2 START/STOP 41 43 RUNFILTER 1 137 AUTO AER TK 4 MIXER 1 40 CARBON FEED PUMP 3 START/STOP 43 FAIL ALARM FILTER 7 FILTER 1 HIGH LEVEL 138 139 RUN AER TK 4 MIXER 1 41 CARBON FEED PUMP 4 START/STOP 44 45 RUN FILTER BACKWASH 140 FAIL AUTO AER TK 4 MIXER 1 AER TK 4 MIXER 2 42 43 SPARE 48 AUTO RUN FILTER 2 FlL1TR 2 141 RUN AER 1K 4 MIXER 2 44 SPARE SPARE 47 FAIL FILTER 2 142 143 FAIL AER TK 4 MIXER 2 45 SPARE 48 AUTO BLOWER 2 AUTO AER TK 4 MIXER 3 46 SPARE 144 RUN AER TK 4 MIXER 3 47 SPARE 49 50 RUN48 AUTO BLOWER 2 145 FAIL AER TK 4 MIXER 3 SPARE 51 RUN BLOWER 4 BLOWER 4 146 AUTO AER TK 4 MIXER 4 52 ALARM FILTER 2 HIGH LEVEL 147 148 RUN FAIL AER TK 4 MIXER 4 53 54 RUN ALARM FILTER 2 BACKWASH 149 AUTO AER TK 4 MIXER 4 SLUDGE BLOWER 1 55 RUN REUSE LOW PRESSURE 1 REUSE PUMP 7 150 RUN SLUDGE BLOWER 1 58 FAIL REUSE PUMP 2 151 FAIL SLUDGE BLOWER 1 152 AUTO SLUDGE BLOWER 2 57 58 ALARM ALARM POWER SYSTEM FAIL GENERATOR FAIL 753 RUN SLUDGE BLOWER 2 EXISTING ANALOG PLG" INPUT SIGNALS PLC1 59 ALARM SLOW R BLOWER CONTROL FAIL 154 FAIL SLUDGE BLOWER 2 NEW ANALOG OUTPUT SIGNALS 60 61 ALARM 1 HIGH TORQUE 155 158 AUTO RW/ CARBON FEED PUMP 1 CARBON FEED PUMP 1 Ai TAG DESCRIPTION AI TAG DESCRIPTION 62 ALARM ALARM CLARIFIER 2 HIGH TORQUE CLARIFIER 3 HIGH TORQUE 157 FAIL CARBON FEED PUMP 1 01 FT102 EFFLUENT FLOW 63 ALARM RAS/WAS WET WELL HIGH 159 CARBON FEED PUMP 2 02 PTI 04 EFFLUENT PRESS 01 RECIRCULATION PUMP 1 SPEED CONTROL 64 ALARM RAS/WAS WET WELL LOW 780 RUN FAIL 2 03 ATI 5 EFFLUENT RESIDUAL 02 03 RECIRCULATION PUMP 2 SP® CONTROL RECIRCULATION ACA FED PP�UMP 04 AT10 EFFLUENT Ph PUMP 3 SP® CONTROL 65 ALARM EFFLUENT WET WELL HIGH 161 AUTO 04 04 RECIRCULATION PUMP 4 SP® CONTROL 66 67 ALARM ALARM SLUDGE TANK LEVEL HIGH 162 RUN CARBON FEED PUMP 3 CARBON FEED PUMP 3 05 06 SPARE SPARE OS CARBON FEED PUMP 1 SP® CONTROL 68 ALARM CHLORINE LEAK ALARM CHLORINE SUPPLY LOW 163 FAIL CARBON F® PUMP 3 07 SPARE O5 CARBON F® PUMP 2 SPEED CONTROL 69 ALARM SO2 LEAK ALARM 164 AUTO CARBON FEED PUMP 4 08 SPARE 07 CARBON FEED PUMP 3 SPEED CONTROL 70 ALARM S02 SUPPLY LOW 185 RUN CARBON FEED PUMP 4 08 CARBON FEED PUMP 4 SPEED CONTROL 71 ALARM MAIN PANEL ALARM 166 166 FAIL SPARE CARBON FEED PUMP 4 09 SPARE 72 RUN REUSE PUMP 2 188 SPARE 10 SPARE 73 74 FAIL AUTO REUSE PUMP 2 189 SPARE 11 12 SPARE SPARE 75 RUN RECIRCULATION PUMP 1 RECIRCULATION PUMP 1 170 SPARE PLCI 78 FAIL RECIRCULATION PUMP 1 171 172 SPAR E SPARE NEW ANALOG INPUT SIGNALS 77 78 AUTO RUN RECIRCULATION PUMP 2 RECIRCULATION PUMP 2 173 174 SPARE Al TAG DESCRIPTION 79 FAIL RECIRCULATION PUMP 2175 SPARE SPARE 80 AUTO RECIRCULATION PUMP 3 176 SPARE 01 FT102 EFFLUENT FLOW 87 ALARM EFFLUENT PUMP T FAIL 177 SPARE 02 03 PT104 ATI 05 EFFLUENT PRESSURE EFFLUENT CL2 RESIDUAL 82 ALARM EFFLUENT PUMP 2 FAIL 178 SPARE b4 ATIO6 EFFLUENT Ph 83 84 ALARM EFFLUENT PUMP 3 FAIL 179 SPARE 05 AT -0-3 EFFLUENT NO3—N 85 ALARMBLOWER 2 FAIL 180 181 SPARE SPARE O6 AT -4-3 BNR NO3—N as 87 ALARMBLOWER 4 FAIL 182 183 SPARE SPARE 07 08 SPARE SPARE as ,84 SPARE 09 P-1-1 RECIRCULATION PUMP 1 SPEED 89 ALARM CL2 INDUCTOR FAIL 185 SPARE 10 P-2-1 RECIRCULATION PUMP 2 SPEED 90 ALARM SO2 INDUCTOR i FAIL 188 SPARE 11 P-3-1 RECIRCULATION PUMP 3 SPEED 91 ALARM S02 INDLUTDR 2 FAIL 187 SPARE 12 P-4-1 RECIRCULATION PUMP 4 SPEED 92 93 ALARM ALARM RAS PUMP 1 FAIL RAS PUMP 2 FAIL ,88 189 SPARE 13 IT -8L2 BLOWER 2 CURRENT 94 ALARM WAS PUMP 1 FAIL 190 SPARE 14 IT—BL4 BLOWER 4 CURRENT 95 ALARM WAS PUMP 2 FAIL 191 SPARE 15 IT—S81 SLUDGE BLOWER , CURRENT 96 RUN RECIRCULATION PIMAP 3 192 SPARE 16 IT—SB2 SLUDGE BLOWER 2 CURRENT 17 FP -1-1 CARBON FED PUMP , SPEED 18 FP -2-1 CARBON FEED PUMP 2 SPEED 19 FP -3-1 CARBON FEED PUMP 3 SPEED 20 FP -4-1 CARBON FEED PUMP 4 SPEED 21 SPARE 22 SPARE 23 SPARE 24 SPARE W. DAVID LASSETTER PE#37971 SCADA SYSTEM 1/0 SCHE REVISIONS CONFORME 12/16/10 FILE NO Lu Z Q J C� L O U J G t— 0 t2 LL LTJ O Ex CIL L F- 3 3 LLC 0 U UAIL OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-13 65 OF 72 SHEETS FP" S49T"" T_..... . NOTES: 1. ALL CONDUIT SHALL BE EMBEDDED IN THE NEW CONCRETE WALKWAYS 2. PROVIDE 1'C SLEEVE FOR EACH SENSOR CABLE EMBEDDED IN THE CONCRETE WALKWAY FROM THE TRANSMITTER TO THE SENSOR. 3. PROVIDE WP RECEPTACLE ADJACENT TO EACH POWER TERMINAL BOX SCALE 3/16' - 1- 0 5 10 W. DAVID LASSETTER PE#37971 CONFORMED 12/16/10 PROJECT FILE NO N C N N � _j DO N J m � C J 020 Cf V1 c o C CIL Lu m C 0 C N .O c) N i U � Lu U Z Q J CCL O U J C� H O a 0 F Z Lu w > O CL 12 3 3 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-15 67 OF 72 SHEETS O ^ Of m ma m 0 CARBON FEED PUMPS CARBON FEED PUMPS 1h2 CONTROL PANEL 3B4 CONTROL PANEL (P406, 5451) (P407, 5452) a L4A-2 L4A-2 C32 u I (P325, 0325) TYPICAL LITHONIA DMW-232-ES-GEB-AL is ELECTRICAL PLAN - SUPPLEMENTAL CARBON FEED SYSTEM SCALE: 3/8' - 1' 1p 910 20 REUSE PUMP NO.2 (P332) REUSE PUMP CONTROL PANEL (P330, C330) ELECTRICAL PLAN - PLANT REUSE PUMP STATION 3/8'=1'-0' SCALE: 3/8' - 1' 10 10 20 FILTER NO.1 CONTROL PANEL (P321, C321) I �' AE -0-3: NEW EFFLUENT NO3-N PROBE WITH 315SS MOUNTING SYSTEM EXISTING EFFLUENT WET WELL LEVEL CONTROL PANEL - MODIFY THE EXISTING CONTROLS (SEE SHEET E-10) O5 10 ELECTRICAL PLAN - FILTERS 2�1-►I MH E3 SCALE: 3/18' = 1' W. DAVID LASSE7TER PE/37971 REVISIONS CONFORME 12/16/10 PROJECT FILE NO C N N � V �N N � J m W C �v as vi 0 0 C � � LL W ca m m Cc— C •Q C? C N •_ y m O UQ� W N U � W U Z Q J C� C O U J C� L O ,L 1 LL o Z CW G W O CEL CLG H 3 3 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-17 69 OF 72 SHEETS FILTER CONTROL PANEL C32 u I (P325, 0325) MN E4 AT -O-3: INSTALL NEW EFFLUENT NO3-N TRANSMITTER WITHIN THE EXISTING FIELD INSTRUMENTATION PANEL PROVIDE NEW POWER AND SIGNAL LINE SURGE PROTECTION. CONNECT OUTPUT SIGNAL TO THE BLOWER BUILDING PLC USING DOSTING SPARE TSP#18. I �' AE -0-3: NEW EFFLUENT NO3-N PROBE WITH 315SS MOUNTING SYSTEM EXISTING EFFLUENT WET WELL LEVEL CONTROL PANEL - MODIFY THE EXISTING CONTROLS (SEE SHEET E-10) O5 10 ELECTRICAL PLAN - FILTERS 2�1-►I MH E3 SCALE: 3/18' = 1' W. DAVID LASSE7TER PE/37971 REVISIONS CONFORME 12/16/10 PROJECT FILE NO C N N � V �N N � J m W C �v as vi 0 0 C � � LL W ca m m Cc— C •Q C? C N •_ y m O UQ� W N U � W U Z Q J C� C O U J C� L O ,L 1 LL o Z CW G W O CEL CLG H 3 3 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-17 69 OF 72 SHEETS DEMOLISH AND REMOVE EXISTING ANTENNA — TOWER CONCRETE FOUNDATION EXISTING MOTOR CONTROL CENTER 3 (C003. SDO3) fr' i r EXISTING MAIN NSTRUMENTATION PANEL (MIP) EXISTING MAIN SWITCHBOARD (SDO6) EXISTING MOTOR CONTROL CENTER 2 (CD02, SDO2) NEW NEMA 4X ALUMINMUM LARGE WALL MOUNTED PULL BOX ol EXTEND THE EXISTING CONCRETE PAD TO ACCOMMODATE THE NEW MCC ELECTRICAL PLAN - BLOWER BUILDING 3/B' = 1'4• SCALE 3/8' — 1' 10 0 10 20 W. DAVID LASSETTER PE#37971 REVISIONS CONFORMED 12/16/10 I FILE NO N C N N cc Jm M cJ� C N �1i LL1 y c .0 C N U N U � Lu z Q J <L L O U J L H r� OLL1 LL o z ri W w O w 12 EL H C� G DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-18 70 OF 72 SHEETS TYPICAL NEW RIGID ALUMINUM CONDUITS SUSPENDED FROM THE CEILING (SEE CONDUIT AND CABLE SCHEDULES) MAIN HEADER BY—PASS VALVE V—G-1 (P470, 5470) z-! z �g �g q ' 8g Om U Om V U m U N ��a �s.' �4 ' 5004, C004 P401 NEW TURBO BLOWER MCP ol EXTEND THE EXISTING CONCRETE PAD TO ACCOMMODATE THE NEW MCC ELECTRICAL PLAN - BLOWER BUILDING 3/B' = 1'4• SCALE 3/8' — 1' 10 0 10 20 W. DAVID LASSETTER PE#37971 REVISIONS CONFORMED 12/16/10 I FILE NO N C N N cc Jm M cJ� C N �1i LL1 y c .0 C N U N U � Lu z Q J <L L O U J L H r� OLL1 LL o z ri W w O w 12 EL H C� G DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-18 70 OF 72 SHEETS ` COMPOSOUTE REINFORCED POLYMER CONTROL STATION MIN. 4' RIGID ALUMINUM CONDUIT SUPPORT POST WITH MINIMUM 6"x 2" x 5/16" CONCRETE SERVICE BOX AND LOCKING AT 4'-0" A.F.F. ALUMINUM CHANNEL WITH WELDED BASE PLATE ALUMINUM FRAM (CAST U PLACE COVER WITH MOLDED "ELECTRIC' LOGO; SURFACES BELOW GRADE OR EMBEDDED IN CONCRETE. MINIMUM: 31rx 24. 16' DEEP (POWER ELECTRICAL EQUIPMENT ENCLOSURE 24". 18'. 18' DEEP (INSTRUMENTATION) III .; II 12" I•�- 12' MIN. I I MA 4X ALUM BOX ALUMECOVER) J (nl 8 MIN 1/2" X 3" ALUM FLAT BAR _III I I II 2! WARNING TAPE 2'-D. SUPPORT CHANNEL (TYPICAL) o N I •II I -: ":•- x;:'K;:' ;,.'�„ SCH 40 PVC CONDUITS 4• TWO SECTION ALUMINUM I�' „.`,".'• `' .-'-=:�. = UNDERGROUND (TYPICAL) III I DIRECTBURIED UCONDUIT CONDUITS m _ DUIT -III—III -I PER GROU D ROD WITH ALUMINTIGHT UM CONNEBLE CTORS 2.5" MIN. SPACING CABLE SCHEDULE HECKERED PLATE OVER MOTOR POWER AND CONTROL I I CONDUITS PER SCHEDULE TYPICAL DIRECT BURIED CONDUIT DETAIL TYPICAL UNDERGROUND PULL BOX DETAIL TYPICAL MOTOR CONNECTION NOT TO SCALE NOT TO SCALE H _20 LOAD RATING NOT TO SCALE NOTES: I I 1. SEE ELECTRICAL SITE PLAN AND CONDUIT AND CABLE ALUMINUM FLAT BAR SUPPORT SCHEDULE FOR NUMBER AND SIZE OF CONDUITS. ` MIN. 4' RIGID ALUMINUM CONDUIT SUPPORT POST WITH PIPE CAPS. PROVIDE MASTIC SEAL COATING ON ALL ALUMINUM FRAM (CAST U PLACE SURFACES BELOW GRADE OR EMBEDDED IN CONCRETE. ELECTRICAL EQUIPMENT ENCLOSURE ���.� �I I•�- 12' MIN. MIN 1/2" X 3" ALUM FLAT BAR SUPPORT CHANNEL (TYPICAL) o 4• TWO SECTION ALUMINUM m r i CONDUIT SUPPORT POSTS (TYPICAL) HECKERED PLATE OVER I I H _20 LOAD RATING I I ALUMINUM FLAT BAR SUPPORT I I CHANNEL (TYPICAL) r REINFORCED0 CONCR TE ( H -2LOAD RATINGF} I I I CONDUIT ENTRANCE OPENING � L J KNOCKOUT WINDOW o(TYPICAL EACH WALL) — _ = I III 12" MIN. 2" MIN 4 REINFORCED CONCRETE T124" MIN 6" SO. x 5" DEEP EQUIPMENT PAD g• g. SUMP T ELECTRICAL EQUIPMENT ENCLOSURE T PROVIDE 12" DIAMETER CONCRETE FOOTER FOR EACH SUPPORT POST TYPICAL ELECTRICAL MANHOLE DETAIL TYPICAL ELECTRICAL EQUIPMENT MOUNTING DETAIL NOT TO SCALE NOT TO SCALE NOTES: 1. PROVIDE A MINIMUM OF ONE 10' LONG GROUND ROD AT EACH ELECTRICAL MANHOLE. W. DAVID LASSETTER PE#37971 REVISIONS CONFORMED 12/16/10 PROJECT FILE NO C N N J C"4 N � Do m J C 0 v Elf N c 0 CSN �[L W to W m w— C .O m C N O 1A In N U Q r W N U Obi Lu Z .�Q • J ACL O U J 0 O LL 1 LL O z Lu O LL 0 14 ty Q - H 3 DATE OCT. 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET E-19 71 OF 72 SHEETS T m P100: PROVIDE NEW UNDERGROUND PRIMARY SERVICE CONDUITS (1WO 4' SCH 40 PVC. MINIMUM 48" COVER. GIS LONG RADIUS ELBOWS) FROM THE 1 TRANSFORMER PAD 70 THE JEA SERVICE POLE AND ITERMINATE IN ACCORDANCE WITH JEA REQUIRMENTS 1 NEW JEA PAD MOUNTED SERVICE TRANSFORMER (480/277 VOLT, 3 PH SERVICE) I ONEW SERVICE METERING 1 C101 PER JEA REQUIREMENTS P101 I 600 ) 1 UL SERVICE ENTRANO: RATED MAIN BREAKER WITH Elml \ OVERSIZED NEMA 4X X>TAINLESS STEEL ENCLOSURE TO ACCOMMODATE BOTTOM LINE AND LOAD CONDUIT 1 ENTRY (CUTLER HAMMER WNHND). _ GROUNDING GRID (MAX 10 OHMS) 1 1 P102 1 1 NEW ASCO 7000 DELAYED TRANSITION AUTOMATIC I TRANSFER SWITCH WITH NEMA 12 FREE STANDING 1 ENCLOSURE WITH OPEN BOTTOM FOR INSTALLATION ON MAIN gimTOP OF CONCRETE CURB WIREWAY. THE ATS SHALL BE 3p EQUIPPED WITH BOTTOM LINE AND LOAD CONNECTONS. BREAKER THE ATS SHALL BE ECUIPPED WITH THE FOLLOWING DRYCONTACTS: ATS NORMAL, ATS i 1 NORMAL SOURCEI AVAILABLE, EMERIGENCYRSOURCE 1 AVAILABLE 1 NEW MOTOR CONTROL CENTER "MCC- (600 AMP, 480 VOLTS, 3 PHASE, 3 WIRE, 65,000 AIC) im>� 1SiQ ` \ \ 20 . 60 .) 20 .) _ / _ / m 1 30 KVA DRY TYPE TRANSFORMER 480-12EVOLTSFA 3 PHASE, E, 4 HARE P105 PANEL I 100kA L ELECTRONIC METERING WITH ETHERNET PORT FOR SCADA NETWORK CONNECTION (POWER MEASUREMENT ION 7300 -EO) POWER SURGE GENERATOR LIGHTING METERING PROTECTION HEATER PANEL I THE MCC SHALL BE EQUIPPED WITH A COMPLETE SPARE 1 1 VERTICAL SECTION TO ACCOMMODATE FUTURE ODOR P704. CI04 1 CONTROL SYSTEM EQUIPMENT. INCLUDE SPARE 3OA/3P A t _- _-_ - - - __ _ -- 1 AND BOA/3P FEEDER BREAKERS WITHIN THIS VERTICAL -J AND 6O. 1 JACKET WATER HEATER AND BATTERY CHARGER PIGS, P106 I RELOCATE AND RECONNECT EXISTING STANDBY gpp GENERATOR. FIELD VERIFY AND REPORT THE EXISTING GENERATOR 1 MAIN BREAKER MAKE, MODEL NUMBER AND TIRP I •/ O BSYrnTIN ENO THE ENGINEER. ADJUST AS DIRECTED P103. 0703 NEW EXISTING ELECTRICAL STANDBY SERVICE GENERATOR NOTES- 1. OTES1. PROVIDE COMPLETE AUTOMATIC SEQUENTIAL REMOTE CONTROL OF THE WASTEWATER PUMP VARIABLE FREQUENCY DRIVES FROM THE NEW PUMP STA7ION CONTROL PANEL PL.C. PROVIDE SUPERVISORY MONITORING AND CONTROL FROM THE SCADA SYSTEM HMI AT WWTP/7. PROVIDE OPERATOR SELECTABLE CONSTANT LEVEL OR PUMP DOWN MODES OF OPERATION. PROVIDE OPERATOR ADJUSTOU3LE WET WELL LEVEL SETPOINT FROM THE SCADA SYSTEM. 2. THE EXISTING STANDBY GENERATOR MUST REMAIN IN SERVICE AT WWTP/2 UNTIL THE NEW PUMP STATION IS COMPLETE AND PLACED IN SERVICE PROVIDE TEMPORARY STANDBY GENERATOR FOR THE PUMP STATION DURING RELOCATION OF THE EXISTING STANDBY GENERATOR. THE TEMPORARY STANDBY GENERATOR SHALL BE MINIMUM 175KW. THE AUTOMATIC CONTROLS SHALL BE INTERLOCKED TO INHIBIT OPERATION OF THE LAST LAG PUMP WHEN OPERATING ON STANDBY POWER. 3. THE NEW PUMP STATION COIITROL PANEL, INCLUDING BUBBLER SYSTEM AND MASTER PUMSHALL P STATIONCON'RiOL PANEL MANPROVIDED BY THE CITY OF UFACTURER: IC EG CONTROLS STANDARD INC., JACKSONVILLE, FL 904-.292-0110. TYPICAL EXPLOSION PROOF CONDUIT SEALING FITTING WITH PERMANENT SEALING COMPOUND TYPICAL CLASS 1. ZONE 2, EXPLOSION PROTECTED TYPE Ex TERMINAL BOXES (ROSE+BOPLA PART NUMBER 34504016) CONDUIT SIZE PER EQUIPMENT CABLE REQUIREMENTS (TYPICAL) VFD P11 70 No.1 No.2 WASTEWATER PUMPS R III G A C120 c#�- P130, C130 70 No.3 ALL EQUIPMENT LOCATED WITHIN THE WET WELL AND EXPOSED TO POTENTIAL HAZARDOUS CONCENTRATIONS OF FLAMMABLE GASES OR VAPORS SHALL BE RATED FOR CLASS I, DIVISION 1, GROUP D LOCATIONS. ALL ELECTRICAL EQUIPMENT AND INSTALLATION SHALL BE SUITABLE FOR CORROSIVE CONDITIONS. 100 AMP MCB 96 AMPS LIGHTING PANEL L NEMA 1C 120/208VOLTS/3 H/ 4IN CKT 1 3 5 7 LOAD DESCRIPTION LTGS - INTERIOR RCTS - INTERIOR LTGS - EXTERIOR RCTS -EXTERIOR POLE TRIP 1 20 1 20 1 20 1 20 KVA 0.2 0.6 0.7 0.2 CKT 2 4 6 8 LOAD DESCRIPTION PUMP STA CNTRL PNL BUBBLER SYSTEM BACKUP CONTROLS SPARE POLE TRIP KVA 1 20 1.0 1 20 1.0 1 20 0.2 1 tp -__ 9 SPARE 1 20 --- 10 SPARE 1 20 --- 11 SPARE 1 20 --- 12 SPARE 1 20 --- 13 _F5 SPARE 1 20 --- 14 SPARE 1 PO --- SPARE 1 20 --- 16 SPARE 1 20 --- 17 SPARE 1 20 --- 18 SPARE 1 20 --- SPARE 1 20 --- 20 SPARE 1 20 --- SPARE 1 20 --- 22 SPARE 1 20 --- 23 SPARE 1 20 --- 24 SPARE 1 PO _ BATTERY CHARGER 1 20 1.0 26 TVSS 3 30 --- t29 HVAC SYSTEM 2 20 3.4 28 TVSS __ -- -- HVAC SYSTEM - -_ ___ 30 TVSS TYPICAL' NEW VARIABLE FREQUENCY DRIVE SHALL BE IN ACCORDANCE WITH LATEST CITY OF ATLANTIC BEACH STANDARDS (CUTLER -HAMMER SVX9000). EACH VFD SHALL BE EQUIPPED WITH AN INTEGRATED INPUT LINE REACTOR (MINIMUM 5%). DV/DT OUTPUT FILTER, AND SSRV CONSTANT SPEED BYPASS NEW PUMP STATION CONTROL PANEL y SnP-CyR BUBBLER SYSTEM ALLEN- SLC 500 Dlq-GAGE 2300 PROVIDE BUBBLER LUBE ACCESS 0140 HL LL START STOP PROVIDE BACKUP FLOAT SWITCHES WITH 316SS CABLE HANGERS. EG CONTROLS BUBBLER SYSTEM WITH DUPLEX AIR COMPRESSORS AND BUBBLER AIR MANAGEMENT SYSTEM (BAMS) EG CONTROLS BUBBLER SYSTEM LEVEL CONTROLLER WITH AUTOMATIC BUBBLER TUBE NR PURGE CONTROLS SNB -UP SLEEVE OUTSIDE ELECTRICAL BUILDING 1'x 1'x 1/2" SS TEE, PLUG, AND UNION. 1/2' 316SS TUBING. EXTEND TO CONTROL PANEL WITHIN 2' PVC SLEEVE 316SS CLAMP AROUND BUBBLER PIPE TO REST ON PVC PIPE 316SS PIPE STRAP WITH 316SS ANCHOR BOLTS 316SS SET SCREW 3' CPVC PIPE SLEEVE 1' 316SS BUBBLER PIPE WITH MIN. OF (3) 1/2' DEEP V -NOTCHES AT BOTTOM NEW BUCCANEER PUMP STATION ELECTRICAL LOAD CALCULATIONS WASTEWATER PUMP 1 70 HP 96 AMPS WASTEWATER PUMP 2 70 HP 96 AMPS WASTEWATER PUMP 3 70 HP 96 AMPS TOTAL MOTOR LOAD 288 AMPS LIGHTING AND CONTROLS 30 KVA 36 AMPS GENERATOR HEATER 6 KVA 13 AMPS TOTAL CONNECTED LOAD 337 AMPS TOTAL NON -COINCIDENTAL LOAD 96 AMPS PEAK DEMAND AMPS 241 AMPS PEAK DEMAND KVA 200 KVA PEAK STANDBY POWER DEMAND 160 KW 0.25 X LARGEST MOTOR 24 AMPS MIN SERVICE AMPACITY 361 AMPS MIN SERVICE ENTRANCE BREAKER 451 AMPS NEW ELECTRICAL SERVICE: 600 AMP, 480/277 VOLT, 3 PHASE, WYE JEA FAULT CURRENT LETTER: ??,9?? AIC W. DAVID LASSETTER PE/37971 Ism REVISIONS CONFORMED 12/16/2010 I FILE NO N C C U N m 4) 1 > C4 N C J m v rnvi�o CY CULL CU � 3 � Q TIi N N N 7 Lu Z Q J CL O U J C t— O IL H Z LCL W O IY (L CL 3 LL A 0 V E NOV 2010 JE AS SHOWN ,WN BY JCA ICNED BY WDL ET BE -1 OF 12 SHEETS L-8 N L-4 N CB4 C83 N N EDCO HSP1218TI I I EDCO HSP121BTI I CB I 1 CB SURGE SURGE PLC POWER SUPRESSOR SUPRESSOR SUPPLY 120V INTRINSICALLY SAFE RELAY PLC SLC ISR CPT 500/05 24V r-----1 HIGH LEVEL SCADA I FLOAT SYSTEM I HLR DIG -GAGE ETHERNET I 2300 I SWATCH HIGH ETHERNET L -_-_-J PORT HLR LEVEL PNEUMATIC INPUT _ _ _ _ IaI ANALOG OUTPUT A BUBBLER WET WELL LEVEL ®--------�}-- WET WELL LEVEL ANALOG INPUT ------ ANALOG OUTPUT LLL (4-20 mA) WET WELL LEVEL - ---_-_--�-- SPARE LOW LEVEL (4-20 mA) FLOAT COMPR LLR � PURGE AIR SOLENOID OUTI E ICR DIGTAL OUTPUT LOW 1 PUMP 1 CALL TO RUN LLR LEVEL SOL A OR 022 PURGE ISOLATION SOLENOID ANALOG INPUT ------ ANALOG OUTPUT PUMP 1 SPEED _ _ _ _ _ _ - _ _ _ _ PUMP 1 VFD SPEED CONTRA. (4-20 mA) _ - (4-20 mA) HLR BCR � BAMS -208 OUT2 ICR DIGITAL OUTPUT BACKUP 2 PUMP 2 CALL TO RUN CONTROLS LLR BCR ACTIVE WARNING _ _ - _ _ _ A (0'.33 ANALAIR SUPPLY WARNING PUMPO2 SPEEDPUT -L(-XJT4 --_--- PUMP 22 VFD ALOG OUTPUT CONTRA. (4-20 mA) _- (4-20 mA) FAILED SCR MCR2A CR AIR SUPPLY FAILED 81R SET O 10s ICR DIGITAL OUTPUT 3 PUMP 3 CALL TO RUN MCR3A 120V SIMPLEX ANALOG INPUT------ ANALOG OUTPUT RECEPTACLE PUMP 3 SPEED _- _ - _ _ _ - _ _ _ PUMP 3 VFD SPEED CONTROL AIR COMPRESSOR (4-20 mA) _- (4-20 MA) N NOA MCR1A BTR TDE 0-1208 ICR DIGITAL OUTPUT 2 SET 030a 120V SIMPLEX 4 ALARM SILENCE RECEPTACLE AIR COMPRESSOR �M-3j N NO.2 MCR1A SIMPLEX BTR TOE 0-1208 RECEPTACLE 3 SET O SOs AIR COMPRESSOR PURGE PUMP STATION CONTROL PANEL PLC CONTROL WIRING DIAGRAM MCR2A CROI SV01 PURGE AIR HLR SR - `1SOLENOID VALVE ICR1 ICR2 ICR3 ICR4 CR02 SVO2 �� ~4 �� ~4 ¢� �¢ ~4 ALARIA SILENCE L �. _ �I_ _ PURGE ISOLATION PUMP 1 PUMP 2 PUMP 3 ALARM '1'r CALL TO RUN CALL TO RUN CALL TO RUN SILENCE I LOCAL ALARM SILENCE PB PURGE ID VALVE PLC CALL TO RUN CONTACTS TO EACH PUMP VFD ICR4 PLC 'ALARM RESET' OUTPUT PROVIDE CITY OF ATLANTIC BEACH STANDARD BUBBLER TWE WET WELL LEVEL CONTROL SYSTEM AS MANUFACTURED BY EG CONTROLS, INC. INCLUDING DUPLEX BUBBLER AIR COMPRESSORS WITH BUBBLER AIR MONITOR SYSTEM (BAMS -20B), LEVEL MONITORING CONTROLLER NEMA 4X ALARM STROBE AND WITH AUTOMATIC AIR PURL: CONTROLS (AG -GAG= 2300), AIR PURGE I HORN MOUNTED ON EXTERIOR SOLENOID VALVES AND AIR COMPRESSOR. PROVIDE EXTERNAL SR I WALL OF ELECTRICAL BUILDING REPLACEABLE FILTERS ON EACH AIR UNE. PUMP STATION CON ?OL PANEL BACKUP FLOAT CONTROLS PUMP STATION CONTROL PANEL BUBBLER SYSTEM LEVEL CONTROLS BTR1 BTR2 BTR3 HLR CRO3 CRO4 PLC INPUT PLC INPUT PLC INPUT 'HIGH LEVEL' 'AIR SUPPLY WARNING' 'NR SUPPLY FAILED" �/� LLR PLC INPUT BACKUP CALL TO RUN CONTAi'TS TO EACH PUMP VFD 'LOW LEVEL' e7[ W. DAVID L4SSETTER PE/37971 BUCCANEER CONTROL WIRING DIAGR 12/16/2010 I FILE NO N C c N J; 04 lh N Zvi C 0 C� CIL W m73 m N e C Q C N .Q N UQ yNy -01 W U Z Q J 0 O OL J A C0 G F- � O LL) LJ_ O V) H W i1 O W O O ix 0- (L F- 3 3 - NOV 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET BE -3 9 OF 12 SHEETS SCALE: 1/4" = 1'-0" THE ELECTRICAL BUILDING SHALL BE A PRECAST CONCRETE BUILDING AS MANUFACTURED BY OLDCASTLE PRECAST, INC. THE MINIMUM BUILDING DIMENSIONS (20' LONG, 10' WIDE, 10'-5" HIGH) SHALL BE INCREASED AS REQUIRED TO ACCOMMODATE THE EQUIPMENT FURNISHED. TYPICAL i' PVC CONDUIT SLEEVE RT EACH CORNER THROUGH CONDUIT AND CABLE SCHEDULE CONDUIT N0. SIZE COND. CABLE AWG TYPE I VOLT FROM TO FOR NOTES m ___________ I F100 2.00 --- --- --- --- PUMP STATION CONTROL PNL UG PULL BOX SCADA NETWORK REROUTE FO CABLE S110 1.00 --- OPENINGS U� --- MOTOR CONTROL CENTER PUMP 1 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE T100 2.C10 --- --- --- --- SERVICE POLE ELECTRICAL BLDG EXTERIOR FUTURE TELEPHONE T101 1.CO --- --- --- --- ELECTRICAL BLDG EXTERIOR PUMP STATION CONTROL PNL FUTURE TELEPHONE a I X --- --- --- K � z � N I P100 2-4" --- --- --- --- SERVICE POLE SERVICE TRANSFORMER PRIMARY lx I I I o 4 1/0 m I ,a I X I I I b VFD CABLE P101 2-4" 3 EA 500 XHHW2 600 SERVICE TRANSFORMER SERVICE MAIN BREAKER POWER MONITORING CABLE P101 --- 1 EA 4/0 XHHW2 600 SERVICE TRANSFORMER SERVICE MAIN BREAKER NEUTRAL C101 1.50 --- --- --- --- SERVICE TRANSFORMER SERVICE METER METERING P121 3.00 --- --- --- --- PUMP 2 DEMARCATION BOX WET WELL PUMP 2 P102 2-4" 3 EA 500 XHHW2 600 SERVICE MAIN BREAKER AUTO TRANSFER SWITCH POWER P102 --- 2 EA 1 4/0 IXHHW2 600 SERVICE MAIN BREAKER AUTO TRANSFER SWITCH GROUND, NEUTRAL VFD CABLE 5130 1.00 --- --- --- --- MOTOR CONTROL CENTER PUMP 3 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE P103 2-4" 3 EA 500 XHHW2 600 STANDBY GENERATOR AUTO TRANSFER SWATCH POWER P103 --- 2 EA 4/0 XHHW2 600 STANDBY GENERATOR AUTO TRANSFER SWATCH GROUND, NEUTRAL C103 0.75 7 14 THWN 600 STANDBY GENERATOR AUTO TRANSFER SWATCH CONTROL, STATUS, ALM P104 2-4" 3 EA 500 XHHW2 600 AUTO TRANSFER SNATCH MOTOR CONTROL CENTER POWER P104 --- 1 EA 4/0 XHHW2 600 AUTO TRANSFER SWITCH MOTOR CONTROL CENTER GROUND C104 1.OD 13 1 14 1 THWN 600 AUTO TRANSFER SWITCH PUMP STATION CONTROL PNL CONTROL, STATUS, ALM P150 5 3 12 THWN 600 MOTOR CONTROL CENTER STANDBY GENERATOR JACKET WATER HEATER C150 5 3 12 THWN 600 PANEL L STANDBY GENERATOR BATTERY CHARGER L-25 UP10775 3 10 THWN 600 PANEL L HVAC UNIT POWER, GROUND L-27 5 3 12 THWN 600 PANEL L WET WELL AREA GFI POWER, GROUND L-5 SCALE: 1/4" = 1'-0" THE ELECTRICAL BUILDING SHALL BE A PRECAST CONCRETE BUILDING AS MANUFACTURED BY OLDCASTLE PRECAST, INC. THE MINIMUM BUILDING DIMENSIONS (20' LONG, 10' WIDE, 10'-5" HIGH) SHALL BE INCREASED AS REQUIRED TO ACCOMMODATE THE EQUIPMENT FURNISHED. TYPICAL i' PVC CONDUIT SLEEVE RT EACH CORNER THROUGH BUILDING FOR LIGHTNING CONDUIT NO. SIZE PROTECTION DOWNLEAD CONDUCTORS CABLE AWG TYPE VOLT FROM TO FOR 12.12' m ___________ I TYPICAL 2.00 4 1/0 XLP X FLOOR MOTOR CONTROL CENTER PUMP 1 DEMARCATION BOX POWER, GROUND VFD CABLE S110 1.00 --- OPENINGS U� --- MOTOR CONTROL CENTER PUMP 1 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE C110 0.75 7 14 THWN 600 MOTOR CONTROL CENTER PUMP 1 SAFE OFF SO, TS, MD W 0.75 5 14 THWN 600 1 PUMP 1 SAFE OFF PUMP 1 DEMARCATION BOX M a I X --- --- --- K � z � N I I m a m N iV I I II lx I I I o 4 1/0 m I ,a I X I I I b VFD CABLE S120 1,00 --- --- --- 10'-0" BUILDING EXTERIOR MOTOR CONTROL CENTER PUMP 2 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE 10'-6" ROOF LINE 0.75 7 PRE -CAST THWN CONCRETE BUILDING FLOOR PLAN SCALE: 1/4" = 1'-0" THE ELECTRICAL BUILDING SHALL BE A PRECAST CONCRETE BUILDING AS MANUFACTURED BY OLDCASTLE PRECAST, INC. THE MINIMUM BUILDING DIMENSIONS (20' LONG, 10' WIDE, 10'-5" HIGH) SHALL BE INCREASED AS REQUIRED TO ACCOMMODATE THE EQUIPMENT FURNISHED. iI f"Agi DUCTLESS SPLIT SYSTEM HVAC TYPICAL /4/0 BARE COPPER TYPICAL TWE 'Wr LIGHT FIXTURE PAD MOUNTE0WITH 0) OUTDOOR UNIT COUNTERPOISE LOOP ;LITH WI M LAMP AND PE-CR-PER FLANGED PVC CABLE GUARD TO PROTECT PIPING AND ELECTRICAL�� — — — — �- CONNECTIONS BETWEEN OUTDOOR \111,�I x I \ P107 UNIT AND INDOOR UNIT. COLOR SHALL MATCH BUILDING EXTERIOR. TYPICAL AT EACH CORNER: I I PROVIDE GROUND ROD BONDED TO BUILDING FOUNDATION STEEL — — I I INDOOR UNIT WALL MOUNTED a c WITH WIRED REMOTE CONTROL I h I i b I TYPICAL CONCRETE CURB WIREWAY I I WITH ALUMINUM CHECKERED PLATE I ' COVER OVER OPEN SPACES LIGHTING PANEL "L" W I lG i I I TYPICAL TE 'X" LIGHT FIXTURE MOTOR CONTROL CENTER (UTHONIA IND1236, EMERGENCY (MCC) I I --� TYPICAL BOND TO POWER — I LIGHT WITH 2-9W KRYPTON LAMPS) DISTRIBUTION EQUIPMENT I I I i PUMP STATION CONTROL PANEL �< TYPICAL TWE "A" LIGHT FIXTURE AUTOMATIC TRANSFER I i i i I (UTHCNIA DMS-232-ES-GEB-AL, SWITCH (ATS)STROBE $ ALUM BODY WITH 2-F32TS LAMPS) ALARM -- -- ALARM HORN ll� (C142) — — n w (TYPICAL) AT TWO DIAGONAL CORNERS: BOND LIGHTNING PROTECTION DOWNIEAD CONDUCTOR TO COUNTERPOISE --- — — — — — — SERVICE ENTRANCE MAIN BREAKER ELECTRIC SERVICE METER ELECTRICAL BUILDING - EQUIPMENT LAYOUT ELECTRICAL BUILDING - LIGHTING PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE 1/4" 1'-0" 0 4 B 62�� W. DAVID LASSETTER PE/37971 I -LLl -I / BUCCANEER ELECTRICAL BUILDIN REVISIONS CONFORMED 12/16/2010 I FILE NO N CA C J ; M N J m co C �v 07 0 o C W C LL m � m CO C N O o w U Q W yNy � d rn U W U Z Q O J O LL LL. O H W U Lu O ix 4C_ EL_ I — NOV 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET BE -5 11 OF 12 SHEETS CONDUIT AND CABLE SCHEDULE CONDUIT NO. SIZE COND. CABLE AWG TYPE VOLT FROM TO FOR NOTES P110 2.00 4 1/0 XLP 1000 MOTOR CONTROL CENTER PUMP 1 DEMARCATION BOX POWER, GROUND VFD CABLE S110 1.00 --- --- --- --- MOTOR CONTROL CENTER PUMP 1 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE C110 0.75 7 14 THWN 600 MOTOR CONTROL CENTER PUMP 1 SAFE OFF SO, TS, MD C111 0.75 5 14 THWN 600 1 PUMP 1 SAFE OFF PUMP 1 DEMARCATION BOX TS, MD P111 3.00 --- --- --- --- PUMP 1 DEMARCATION BOX WET WELL PUMP 1 P120 2.00 4 1/0 XLP 1000 MOTOR CONTROL CENTER PUMP 2 DEMARCATION BOX POWER, GROUND VFD CABLE S120 1,00 --- --- --- --- MOTOR CONTROL CENTER PUMP 2 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE C120 0.75 7 14 THWN 600 MOTOR CONTROL CENTER PUMP 2 SAFE OFF SO, TS, MD C121 0.75 5 14 THWN 600 PUMP 2 SAFE OFF PUMP 2 DEMARCATION BOX TS, MD P121 3.00 --- --- --- --- PUMP 2 DEMARCATION BOX WET WELL PUMP 2 P130 1 2.00 4 1/0 XLP 1 1000 MOTOR CONTROL CENTER PUMP 3 DEMARCATION BOX POWER, GROUND VFD CABLE 5130 1.00 --- --- --- --- MOTOR CONTROL CENTER PUMP 3 DEMARCATION BOX MOTOR SENSORS MONITORING CABLE C130 0.75 7 14 THWN 600 MOTOR CONTROL CENTER PUMP 3 SAFE OFF SO, TS, MD C131 0.75 5 14 THWN 600 PUMP 3 SAFE OFF PUMP 3 DEMARCATION BOX TS, MD P131 3.00 --- --- --- --- PUMP 3 DEMARCATION BOX WET WELL PUMP 3 C140 1.00 5 14 THWN 600 PUMP STATION CONTROL PNL PUMP 3 DEMARCATION BOX LSH, LSL C141 1.50 --- --- --- --- PUMP 3 DEMARCATION BOX WET WELL LSH, LSL C142 1 0.75 5 14 THWN 1 600 PUMP STATION CONTROL PNL ALARM STROBE AND HORN POWER, CONTROL P150 4-2" --- --- --- --- MOTOR CONTROL CENTER STUB -OUT OF BUILDING FUTURE C150 4-2" --- --- --- --- PUMP STATION CONTROL PNL STUB -OUT OF BUILDING FUTURE iI f"Agi DUCTLESS SPLIT SYSTEM HVAC TYPICAL /4/0 BARE COPPER TYPICAL TWE 'Wr LIGHT FIXTURE PAD MOUNTE0WITH 0) OUTDOOR UNIT COUNTERPOISE LOOP ;LITH WI M LAMP AND PE-CR-PER FLANGED PVC CABLE GUARD TO PROTECT PIPING AND ELECTRICAL�� — — — — �- CONNECTIONS BETWEEN OUTDOOR \111,�I x I \ P107 UNIT AND INDOOR UNIT. COLOR SHALL MATCH BUILDING EXTERIOR. TYPICAL AT EACH CORNER: I I PROVIDE GROUND ROD BONDED TO BUILDING FOUNDATION STEEL — — I I INDOOR UNIT WALL MOUNTED a c WITH WIRED REMOTE CONTROL I h I i b I TYPICAL CONCRETE CURB WIREWAY I I WITH ALUMINUM CHECKERED PLATE I ' COVER OVER OPEN SPACES LIGHTING PANEL "L" W I lG i I I TYPICAL TE 'X" LIGHT FIXTURE MOTOR CONTROL CENTER (UTHONIA IND1236, EMERGENCY (MCC) I I --� TYPICAL BOND TO POWER — I LIGHT WITH 2-9W KRYPTON LAMPS) DISTRIBUTION EQUIPMENT I I I i PUMP STATION CONTROL PANEL �< TYPICAL TWE "A" LIGHT FIXTURE AUTOMATIC TRANSFER I i i i I (UTHCNIA DMS-232-ES-GEB-AL, SWITCH (ATS)STROBE $ ALUM BODY WITH 2-F32TS LAMPS) ALARM -- -- ALARM HORN ll� (C142) — — n w (TYPICAL) AT TWO DIAGONAL CORNERS: BOND LIGHTNING PROTECTION DOWNIEAD CONDUCTOR TO COUNTERPOISE --- — — — — — — SERVICE ENTRANCE MAIN BREAKER ELECTRIC SERVICE METER ELECTRICAL BUILDING - EQUIPMENT LAYOUT ELECTRICAL BUILDING - LIGHTING PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE 1/4" 1'-0" 0 4 B 62�� W. DAVID LASSETTER PE/37971 I -LLl -I / BUCCANEER ELECTRICAL BUILDIN REVISIONS CONFORMED 12/16/2010 I FILE NO N CA C J ; M N J m co C �v 07 0 o C W C LL m � m CO C N O o w U Q W yNy � d rn U W U Z Q O J O LL LL. O H W U Lu O ix 4C_ EL_ I — NOV 2010 SCALE AS SHOWN DRAWN BY JCA DESIGNED BY WDL SHEET BE -5 11 OF 12 SHEETS