Permit Addition 1946 Beachside Ct 2011 . "144 s CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 s X33 Application Number . . . . . 11- 00001712 Date 3/01/11 Property Address 1946 BEACHSIDE CT Application type description RESIDENTIAL ADDITION Property Zoning TO BE UPDATED Application valuation . . . 10000 Application desc ADD 120 SF ADDITION TO DINING ROOM IN REAR OF HSE Owner Contractor POWERS SHIELA ANNE ALESCH CONTRACTING INC 1946 BEACHSIDE COURT 1946 BEACHSIDE CT ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 613 -6517 Structure Information 000 000 Construction Type . . . . . TYPE 5 -B Occupancy Type RESIDENTIAL Flood Zone ZONE X Permit BUILDING PERMIT Additional desc . Permit Fee . . . 100.00 Plan Check Fee . . 50.00 Issue Date . . . Valuation . . . . 10000 Expiration Date . 8/28/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination in needed, call 247 -5834. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. Other Fees STATE DCA SURCHARGE 2.00 ENG REV PRE APP > 3 HRS 25.00 iT fiKIiH SURCHARGE r� 2.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY "Ot 4 tLAl'Q i'IC A15A H`IN E�s D THE FLORA. 0 0 BUILDING CODES. 5 LAN y r ` CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ° X ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 a ' -QF0`' Page 2 Application Number 11- 00001712 Date 3/01/11 Fee summary Charged Paid Credited Due Permit Fee Total 100.00 100.00 .00 .00 Plan Check Total 50.00 50.00 .00 .00 Other Fee Total 54.00 54.00 .00 .00 Grand Total 204.00 204.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247 -5826 Fax (904) 247 -5845 Job Address: 1946 Beachside Ct Atlantic Beach Permit Number: / f — / 7 / cL Legal Description 42 -14 09- 2S-29E BEACHSIDE LOT 26 BLK 1 Parcel # LOT 26 BLK 1 Floor Area of Sq.Ft. Sq.Ft Valuation of WorMOBtfir Proposed Work heated/cooled I non- heated/cooled 40 j ° °o c) Class of Work (circle one): New Addition iteration Repair Move Demolition pool'spa v(1657711 Use of existing/proposed structure(s) (circle one)): Commercial esidential If an existing structure, is a fire sprinkler system installed? (Circle one): es No N A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed:Extend D' ' • room on back side of house _.,41Lll44i,•4.Ifa►aR.41'�:at4.44 4 Property Owner Information: Name: Sheila Powers Address:1946 Beachside Ct City Atlantic Beach State FLZip 32233 Phone 904 -463 -6989 E -Mail or Fax # (Optional)sheila(a)ttensalon.net Contractor Information: Company Name: Alesch Contracting, Inc Qualifying Agent: Theodore Alesch Address:1946 Beachside Ct City Atlantic Beach State FL Zip 32233 Office Phone 904 -613 -6517 Job Site Contact Number c Fax # JJ/A _ State Certification/Registration # CGC 1516238 Architect Name & Phone # NtQ Engineer's Name & Phone # _ ;a L 3. t-( L.• • E . • r _ — 0:: • Fee Simple Title Holder Name and Address ■ Pt Bonding Company Name and Address • ,A4 Mortgage Lender Name and Address nl( Application is hereby made to obtain a permit to do the work and installations as indicated 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction This permit becomes null and void if work is not commenced within six (6) months, or if constrvction or work is suspended or abandoned for a period of sir (6) months at am time filer work is commenced 1 understand that separate permits must be secured for Elecmcal Work, Plumbing, Signs, Walls, Pools, Furnaces, Boilers, Heaters, Tanks and Air Cond etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 1 hereby certify that I have read and examined this a ptication and know the same . to be true and correct All provisions Flaws and ordinances governin this type of work .4l be complied with whether specified herein or not The granting of a permit does not presume to • ' authority to vi. •to or cancel the provisions of any other federal, state, or local law regulating construction or the perfonnaoe afconstruction. ` Signature of Owne � / Signature of Contractor A ,I 1/ '"'" °, Print Name 6 44J7 ' /e.f' S Print Name �, x,11 L ! � <L r� A 1 . ............ . . Suit 4 d subscribed re me Sw ubscried �f me thi • - Day of . 20 1/ this Day of 1� 2 --''J , 20 Notary Public Notary Public A Revised 01.26.10 . _ - __3 /YI 7" � 9"2 O .11 i , `�'` : x? �) i € ! : . , t oQMM1s$I0N # BD 634126 .,,cr � ' a ,� *.ate -rr . : ' ,. r- �„ ; r X�IFi B ! la l l 1 ,t 01l .„ . ,- t .. �� a „ ,f' A ! , {, x t I of 4 ryptary Pu blic Undsrwiiisre 4 ' q FILE COPY , ti j FCY :,:,-; :, ) i:',' .. , fill_____........,.. ...,..,_,, G,' t'i . 'd y- ' T DO NOT WRITE BELOW - OFFICE USE ONLY Dplicable Codes: 2007 Florida Building Code w/ 2009 Revisions eview Result (circle one): pproved Disapproved Approved w/ Conditions .eview Tnitials/Date: /71? r9l� y/« 2evclopment Size [abitable Space /,-).c? S rr Non Habitable 1 ( ' se Impervious area Ladon/D CA/DBPR$ ✓Iiscelaneous Information )ccupancy Group /GPs ype of Construction 5=5 T Tumber of Stories / oning District IQ. (r tr1'� VIax. Occupancy Load Fire Sprinklers Required Flood Zone J, Conditions /Comments: CITY OF ATLANTIC BEACH PRODUCT APPROVAL SPECIFICATION SHEET (short form) As required by Florida Statute 553.842 and Florida Administrative Code 9B -72, please provide the information and approval numbers on the building components listed to be utilized on the construction project for which you are applying. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Statewide approved products are listed online @ www.floridabuilding.org Category/Subcategory Manufacturer Product Description FL Approval # (s) EXTERIOR DOORS a. Swinging rip....wui.oi1W' iii7: it =■Ai'dc b. Sliding - ���[or:'r�' rAiidPlv.�1►���•7■ - , - c. Sectional /Roll Up d. Other WINDOWS • a. Single /Double Hung 111; __.__.i�oi "'- l „„ _ orrotag _.* 6 ii , r • b. Horizontal Slider - , c. Casement 12068 , -1 d. Fixed e. Mullion f. Skylights g. Other PANEL WALL a. Siding b. Soffits c. Storefronts d. Glass Block e. Other f ,r1Q — ( 1it/Ul2vlt Fi___(1 143 t ROOFING PRODUCTS a. Asphalt Shingles G - (z•I,No - FL- (0(2 •1(r, b. Non - Structural Metal e,6 t Q FL- -- lc - G -6 1 : - \ c. Roofing Tiles d. Single Ply Roof e. Other . t C� ` 'L- t q e) 142. STRUCTURAL COMPONENTS a. Wood Connectors 51011290 a_ 1,14ri (' b. Wood Anchors 5 WI 19614) (33 2G c. Truss Plates d. Insulation Forms e. Lintels f. Others NEW EXTERIOR ENVELOPE I understand that, at the time of inspection, the following information must be available to the inspector on the jobsite: 1. A copy of the product approval. 2. The list of performance characteristics which the product was tested and certified to comply with. 3. A copy of the applicable manufacturers' installation requirements. Furt - I unde . nd a product may have to be removed if approval cannot be demonstrated during inspection. All illi ?talc\ App .nt gnature Date H: /Product approval spec sheet short formadsx FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Alesch Residence Builder Name: Owner Street: 1946 Beachside Court Permit Office: Atlantic Beach City, State, Zip: Atlantic Beach , FL , Permit Number: Owner: Alesch Jurisdiction: 261100 Design Location: FL, Jacksonville 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R =11.0 2048.00 ft b. Frame - Wood, Adjacent R =11.0 200.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 3 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft 1841 a. Under Attic (Vented) R =19.0 1363.00 ft b. N/A R= ft 7. Windows Description Area c. N/A R= ft a. U- Factor: Sgl, U =0.32 290.50 ft SHGC: SHGC =0.30 11. Ducts b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Attic Sup. R= 6, 368.2 ft SHGC: 12. Cooling systems c. U- Factor: N/A ft a. Central Unit Cap: 41.6 kBtu/hr SHGC: SEER: 13 d. U- Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.1 kBtu/hr e. U- Factor: N/A ft2 HSPF:7.7 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 allons a. Slab -On -Grade Edge Insulation R =0.0 1363.00 ft2 g EF: 0.92 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat Glass/Floor Area: 0.158 Total As -Built Modified Loads: 35.21 PASS Total Baseline Loads: 41.68 I hereby certify that the plans and specifications covered by Review of the plans and Oi S •.. this calculation are in compliance with the Florida Energy specifications covered by this ; 1+ .. O . Code. „ calculation indicates compliance ` fi r 1 ' Robert Fultz with the Florida Energy Code. F- ;, „k ,,,, „ { O 't PREPARED BY m "�OO Before construction is completed - -- * 'z DATE: this building will be inspected for ` -.. " . , a compliance with Section 553.908 " -.: a *: �C I hereby certify that this �l ing, a e . Florida Statutes. ✓ " i ned, i in compliance -.�.c ..,.•..,...... •: �4 t with the Florida Energy .... OD wEll ... OWNER/AGENT: BUILDING O FFICIAL: r DATE: \, \ DATE: ,_..1F1 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with N1110.A.3. 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 1 of 6 PROJECT Title: Alesch Residence Bedrooms: 3 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 1841 Lot # Owner: Alesch Total Stories: 2 SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Owner Rotate Angle: 0 Street: 1946 Beachside Court Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City, State, Zip: Atlantic Beach , Family Type: Single - family FL , New /Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Jacksonville FL_JACKSONVILLE_INT 2 32 93 75 70 1281 49 Medium FLOORS # Floor Type Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation 175 ft 0 1363 ft 0.2 0 0.8 ROOF V / Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 1579 ft 0 ftz White 0.96 No 0 30.3 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1363 ft N N CEILING V # Ceiling Type R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) 19 1363 ft 0.11 Wood WALLS Cavity th V # Ornt Adjacent To Wall Type R -Value Area Shea -Value ing Fraction Framing Solar Absor. 1 N Exterior Frame - Wood 11 256 ft' 0.19 0.75 2 W Exterior Frame - Wood 11 360 ft' 0.19 0.75 3 S Exterior Frame - Wood 11 16 ft 0.19 0.75 4 N Exterior Frame - Wood 11 64 ft 0.19 0.75 5 S Exterior Frame - Wood 11 280 fr 0.19 0.75 6 E Exterior Frame - Wood 11 24 ftz 0.19 0.75 7 SE Exterior Frame - Wood 11 24 ft 0.19 0.75 8 E Exterior Frame - Wood 11 32 ft 0.19 0.75 9 NE Exterior Frame - Wood 11 24 ft 0.19 0.75 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 2 of 6 WALLS Cavity Sheathing Framing Solar V # Ornt Adjacent To Wall Type R -Value Area R -Value Fraction Absor. 10 E Exterior Frame - Wood 11 80 ft 0.19 0.75 11 SE Exterior Frame - Wood 11 24 ft 0.19 0.75 12 E Exterior Frame - Wood 11 16 ft 0.19 0.75 13 N Garage Frame - Wood 11 16 ft 0.19 0.01 14 E Garage Frame - Wood 11 160 ft 0.19 0.01 15 S Garage Frame - Wood 11 24 ft 0.19 0.01 16 N Exterior Frame - Wood 11 104 ft 0.19 0.75 17 W Exterior Frame - Wood 11 320 ft 0.19 0.75 18 S Exterior Frame - Wood 11 104 ft 0.19 0.75 19 E Exterior Frame -Wood 11 320 ft 0.19 0.75 DOORS V # Ornt Door Type Storms U -Value Area 1 E Wood None 0.460000 21 ft 2 E Wood None 0.460000 21 ft WINDOWS Orientation shown is the entered, asBuilt orientation. / Overhang V # Ornt Frame Panes NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N Vinyl Single (Tinted) Yes 0.32 0.3 N 18 ft 1.5 ft 0 in 8 ft 0 in HERS 2006 None 2 W Vinyl Single (Tinted) Yes 0.32 0.3 N 42 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 3 W Vinyl Single (Tinted) Yes 0.32 0.3 N 15 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 4 W Vinyl Single (Tinted) Yes 0.32 0.3 N 15 ft 8 ft 0 in 0.5 ft 0 in HERS 2006 None 5 W Vinyl Single (Tinted) Yes 0.32 0.3 N 30 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 6 N Vinyl Single (Tinted) Yes 0.32 0.3 N 35 ft 5 ft 0 in 0.5 ft 0 in HERS 2006 None 7 S Vinyl Single (Tinted) Yes 0.32 0.3 N 30 ft 1.5 ft 0 in 3 ft 0 in HERS 2006 None 8 S Vinyl Single (Tinted) Yes 0.32 0.3 N 9 ft 1.5 ft 0 in 8 ft 0 in HERS 2006 None 9 SE Vinyl Single (Tinted) Yes 0.32 0.3 N 10 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 10 E Vinyl Single (Tinted) Yes 0.32 0.3 N 15 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 11 NE Vinyl Single (Tinted) Yes 0.32 0.3 N 10 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 12 N Vinyl Single (Tinted) Yes 0.32 0.3 N 13.5 ft 1.5 ft 0 in 1 ft 0 in HERS 2006 None 13 W Vinyl Single (Tinted) Yes 0.32 0.3 N 18 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 14 E Vinyl Single (Tinted) Yes 0.32 0.3 N 12 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None 15 E Vinyl Single (Tinted) Yes 0.32 0.3 N 18 ft 1.5 ft 0 in 0.5 ft 0 in HERS 2006 None INFILTRATION & VENTING - -- Forced Ventilation - Run Time Fan V Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 1738 6.30 95.4 179.5 0 cfm 0 cfm 0 0 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 3 of 6 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 446 ft 446 ft 25 ft 8 ft (invalid) COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 13 41.6 kBtu/hr 1248 cfm 0.75 sys#0 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 7.7 27.5 kBtufir sys#0 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft DUCTS - -- Supply -- — Retum -- Air Percent i # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 368.2 ft Attic 92.05 ft Default Leakage Attic (Default) c (Default) % TEMPERATURES Programable Thermostat: Y Ceiling Fans: Jan 'X Feb Cooling Heating X� Jan )C F X] Mar X Apr X� May X Ju n ' C Jul X1 Aug Aug X] S X Oct X N X] Dec • 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 4 of 6 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 5 of 6 FORM 1100A -08 Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 1946 Beachside Court PERMIT #: Atlantic Beach, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm /sq.ft. window area; .5 cfm /sq.ft. door area. Exterior & Adjacent Walls NI 106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows /doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top /bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations /openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi-story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts NI 106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both N1102.B.1.1 sides. Common ceiling & floors R -11. 2/20/2011 11:10 AM EnergyGauge® USA - FlaRes2008 Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD 1 1 ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformance Index, the more efficient the home. 1946 Beachside Court, Atlantic Beach, FL, 1. New construction or existing New (From Plans) 9. WaII Types Insulation Area 2. Single family or multiple family Single - family a. Frame - Wood, Exterior R =11.0 2048.00 ft b. Frame - Wood, Adjacent R =11.0 200.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 3 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft 1841 a. Under Attic (Vented) R =19.0 1363.00 ft b. N/A R= ft 7. Windows ** Description Area c. N/A R= ft a. U- Factor: Sgl, U =0.32 290.50 ft SHGC: SHGC =0.30 11. Ducts b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Attic Sup. R= 6, 368.2 ft SHGC: 12. Cooling systems c. U- Factor: N/A ft a. Central Unit Cap: 41.6 kBtu/hr SHGC: SEER: 13 d. U- Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.1 kBtu/hr e. U- Factor: N/A ft2 HSPF: 7.7 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R =0.0 1363.00 ft2 EF: 0.92 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) ti+� SNE s S .- O , •` •• in this home before final inspection. Otherwise, a new EPL Display Card will be completed , wQ',, f �:'n based on installed Code co • n f..a • e-. ;,.„ , ;• „ : Builder Signature: A A Date: -\ I o l __. __e - a boa S. " '..2 Address of New Home: 1 3 V' City /FL Zip: 2�� .,!4, .. ay « OD WE • *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638 -1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the * *Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 84 The lower the EnergyPerformance Index, the more efficient the home. 1946 B eac h si d e (-nut c Beach FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2 Single family or multiple a family Single a. Frame - Wood. Exterior R=11.0 2048.00 T` b. Frame - Wood, Adjacent R =11.0 200.00 ft 3. Number of units, if multiple family 1 C. N/A R. ft` 4. Number of Bedrooms 3 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types insulation Area 6. Conditioned floor area (ft 1841 a. Under Attic (Vented) R =19.0 1363.00 ft b. N/A R= ft 7. Windows ** Description Area c. N/A R= ft a. U- Factor: Sgl, U =0.32 290.50 ft SHGC: SHGC =0.30 11. Ducts b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Attic Sup. R= 6, 368.2 ft SHGC: 12. Coding systems c. U- Factor: N/A ft a. Central Unit Cap: 41.6 kBtu /hr SHGC: SEER: 13 d. U- Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.1 kBtu /hr e. U- Factor: N/A ft2 HSPF:7.7 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R =0.0 1363.00 ft2 EF: 0.92 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building -cm ST Construction through the above energy saving features which will be installed (or exceeded) ' p4 .. ;. i �FO :. in this home before final i pection Othe ise, a new EPL Display Card will be completed ;vQ',; `'' n.'> °,;>. .r, based on installed Code Ii t = -- i�r. s. "'',, 9,: -., Builder Signature: r Date: C, I di ` � � , A Address of New Home: k /I <;())_ L f City /FL Zip: �� - ?-- , fl, a � 4c d c Department of Community Affairs at (850) 487 -1824. * *Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 MANUAL J, 8TH EDITION BASED HEAT LOAD CALCULATIONS Prepared By: ResCalc of Southwest Florida, Inc. Date: 02/19/2011 PAGE 1 OF 5 JOB NAME Alesch Residence A/C SYSTEM 1 JOB ADDRESS 1946 Beachside Court CONTRACTOR _ Owner PERMITTING OFFICE Atlantic Beach JURISDICTION 261100 DESIGN CONDITIONS Reference City: Jacksonville Latitude: 30 Attitude: 26' WINTER SUMMER Outside db 32 deg F Outside db 93 deg F Inside db 70 deg F Inside db 75 deg F Temp Diff 38 deg F Temp Diff 18 deg F Grains 53 Daily Range M HEATING SUMMARY Design Heating Load Requirments 27556 BTUH COOLING SUMMARY Total Sensible Gain 34352 BTUH Total Latent Gain + 4538 BTUH From Procedure D Total Sensible + Latent 38890 BTUH Submitted Cooling Capacity 41613 BTUH w / 7% of Calculation ResCalc of Southwest Florida, Inc. 616 96th Avenue North Naples, Florida 34108 Office: 239.596.4575 Cell: 239.250.1568 www.rescalc.com bob @rescalc.com JOB NAME: Alesch Residence Page 2 of 4 ADDRESS: 1946 Beachside Court A/C System 1 HEATING REQUIREMENTS DUE TO GLASS AREA AREA DESIGN TEMP DIFF 38 deg F HEATING SQ FT HEATING MULTIPLIER BTUH LOSS Glass Doors, infiltration 0.50 CFM /FT Metal Frame, Single Glass 77.00 41.3 2217.60 Metal Frame, Double Glass 28.8 0.00 Movable Windows .50 CFMIFT Metal Frame, Single Glass 213.50 43.6 7024.15 Metal Frame, Double Glass 32.9 0.00 Awning Windows .50 CFMIFT _ Metal Frame, Single Glass 0.00 45.9 0.00 Fixed or Picture Windows Metal Frame, Single Glass 0.00 35.8 0.00 Metal Frame, Double Glass 25.1 0.00 GLASS AREA BTUH LOSS 290.50 9242 COOLING REQUIREMENTS AREA COOLING MULTIPLIER 18 deg F COOLING DUE TO GLASS AREA SQ FT Single Pane Glass BTUH GAIN Clear Tint Reflective Low -E N 31.50 34 27 24 17 850.50 NO NE & NW 10.00 66 50 52 37 500.00 E & W 150.00 89 68 73 53 10200.00 SHADING SE & SW 10.00 78 59 63 45 590.00 S 39.00 50 37 38 26 1443.00 SHADED All Directions 50.00 34 27 24 17 1350.00 SKYLIGHT Horizontal 0.00 150 91 143 84 0.00 GLASS AREA BTUH GAIN 290.50 14933.50 i JOB NAME: Alesch Residence PAGE 3 OF 5 ADDRESS: 1946 Beachside Court A/C System 1 DESIGN TEMPERATURE DIFFERENCE AREA HEATING HEATING COOLING COOLING ITEM SQUARE MULTIPLIER (BTUH MULTIPLIER (BTUH FEET 38 degrees LOSS) 18 degrees GAIN) Gross Wall Area 2248.00 Glass Area BTUH Loss /Gain 290.50 9241.75 14933.50 Adjacent Wall FRAME, R -11 1/2" Gypsum Board 179.00 _ 2.7 483.30 1.3 _ 232.70 FRAME, R -19 1/2" Gypsum Board 0.00 1.8 0.00 0.9 0.00 CBS Furred, R-4.1 Insulation 0.00 5.2 0.00 2.1 0.00 Doors (Excluding Glass) Solid Wood - Weatherstripped 42.00 21.4 898.80 10.9 457.80 Metal - Urethane Core - Weatherstripped 0.00 13.3 0.00 4.5 0.00 Net Exterior Walls CBS Furred, R-4.1 Insulation 0.00 5.1 0.00 3.3 0.00 CBS Furred, R -5 Insulation 0.00 4.3 0.00 2.3 0.00 FRAME, R -11 1/2" Gypsum Board 1736.50 2.7 4688.55 2.1 3646.65 FRAME, R -19 1/2" Gypsum Board 0.00 1.8 0.00 1.4 0.00 Ceiling Under Attic R- 19Insluation _ 1363.00 4.9 _ 6678.70 5.3 _ 7223.90 R -30 Insulation 0.00 3.1 0.00 3.5 0.00 Ceiling Single Assembly R -19 Insulation 0.00 5.7 0.00 7.4 0.00 R -30 Insulation 0.00 4.1 0.00 4.7 0.00 Floor, Concrete Slab (Perimeter) No Edge Insulation 175.00 24.3 4252.50 0 0.00 Raised Floor Wood Adjacent, R -19 0.00 2.4 0.00 1.5 0.00 Wood Post/Pier, R -19 0.00 2.1 0.00 1.3 0.00 Concrete No Insulation 0.00 1.6 0.00 1.1 0.00 Infiltration - Calculation B 1734.92 Subtotal 26243.60 People (& Appliance Load) 6 _ 3000.00 Sensible BTUH Gain 31229.47 Duct BTUH Loss & Gain R-6 Ductwork 0.05 1312.18 0.1 3122.95 Total BTUH Loss 27555.78 Total Sensible Gain 34352.42 JOB NAME: Alesch Residence PAGE 4 OF 5 ADDRESS: 1946 Beachside Court A/C System 1 CALCULATION PROCEDURES A, B, C, D Calculation Procedure A - Summer Infiltration for the Entire House 1. Air Changes Per Hour (.3 New Construction, .5 Residential) 0.3 AC /HR 2. Volume of Conditioned Space Floor Area x Avg Ceiling Height 1841 9.5 17489.5 CU. FT. 3. Total Infiltration AC /HR X CU.FT X .0167 87.62 CFM Calculation Procedure B - Summer Infiltration 1. Design Temperature Difference Summer Design - Room Temp 18 deg F 2. Total Infiltration form Calculation Procedure A 87.62 CFM 3. Sensible Gain 1.1 x Temp Diff x CFM 1735 Btuh Calculation Procedure C - Latent Infiltration Gain for the Entire House 1. Grain of Moisture Difference for SW Florida 53 Grains 2. Total Infiltration from Calculation Procedure A 87.62 CFM 3. Total Latent Infiltration Load .68 x Grains x CFM 3158 Btuh Calculation Procedure D - Equipment Sizing Calculation Latent Load for Appliances & People No. of People 6 1380 Btuh Latent Infiltration Load from Calculation Procedure C 3158 Btuh Latent: Equipment Sizing Load 4538 Btuh JOB NAME: Alesch Residence PAGE 5 OF 5 ADDRESS: 1946 Beachside Court A/C System 1 SYSTEM SIZING SUMMARY Summer Calculations Windows 10.0% Walls 5.5% 1.5% Ceilings 47.6% s Floors 23.0% Doors Infiltration 12.4% Ducts Winter Calculations Windows 15.0% 4.6% 32.6% Ceilings 2.8% 3.2% Floors Doors 23.6% Latent Gain 18.2% Ducts MAR -3 -2011 12:50 FROM: CLERK OF COURTS 904 270 1512 TO:92475845 P:1 /1 NOTICE OF COMMENCEMENT Permit No. 11-00001112_ Tax Folio No. - State of Florida, County of Duval THE UNDERSIGNED hereby give notice that the improvement will be made to certain real property in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Descri tion property (le 1 de ription of property and address if available): 2. General De- ri.ti•n •f improvemen 3. Owner Information: a) Narne and Address: ~/ b) Interest in property: e • . + A.17- A AZ, ,...,- _ G. _ c) Narne and address of simple titleholder (if other than owner): 4. Contractor Information: ,� p ,( / �J / � a) Name and Address: rift S rev C 1 9 ° (4a7 F— / (9 7s ;, r 6 6X77 rte • �1 b) Phone Number tt/lc f1 t( -6577 v' /1"'" 1 O 5. Surety Information: t a) Name and Address: b) Phone Number: e) Amount of Bond: $ 6. Lender Information: a) Name and Address: b) Phone Number: 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by 713.13 (1)(a) 7, Florida tatutes: a) Name and Address: Alf A b) Phonc Numbers of Designated Person: 8. In addition to himself/herself, Owner designates A of to receive a copy of the Lienor's Notice as provided in Sectio 71 13 (1) (b), Florida Statutes. a) Name and Address: b) Phone Number of person or entity designated by owner: 9 Expiration date of Notice of Commencement (The expiration date is one (1) year from the date of Recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMEN'T'S TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST .INSP.ECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. The fo;l' going instrument was ackn ed before me this Zd ay of 7r-1 _ , 20 r/ .S /tE2, iii-,4/F 6-,e-5 - y 04 _ NOTARY P STATE OF FLORIDA °'.- x26 + �� � L � fi :'y ce ° �i 1 Print Name: r e erdrd - ,_ y_l ' rsonally Known 71 (v (c 2_0 J ldentilitation/Type: >r f 4-ze 7t-/ Verification pursuant to Section 92.525, Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knodge and brligf. ... , 1 4 ii- . --7----,. ( 0. . roc 1c 201104581 /. out 8K 15531 Page 5133, �_ _ _ Signature of Property Owner Number Pages: 1 Recorded 01'0342011 at 11 56 AM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 Revised 10/1/2009 .1!yr4 City of Atlantic Beach APPLICATION NUMBER j . � � Building Department (To be assigned by the Building Department.) ' 1 ti 800 Seminole Road 2 , r Atlantic Beach, Florida 32233 -5445 Phone (904) 247 -5826 • Fax (904) 247 -5845 r x � ' - E -mail: building- dept @coab.us Date routed: �� City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /94 4tdslie 0. Department review required Yes No 1 , :ui••• ✓ Applicant: /6 £ 7411_ /!y , Planning & Zonio":' ✓ - • inistrator Project: Mdf /?4,./)2 o 'e , - • is w• ti-, ✓ lic Utiliti- Public Safety Fire Services R , e , 11 epi Silgna it 4'; ' 3, 1 4 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. (Circle one.) Comments: BUILDIN PLANNING & ZONING Reviewed by: /11 Date: 2-2`( TREE ADMIN. Second Review: Approved as revised. ❑De led. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 i City of Atlantic Beach RECEIVED APPLICATION NUMBER A `r s B uilding Department (To be assigned by the Building Department.) 800 Seminole Road '; ,, FEB 2 8 2011 • - /7/2' 0 Atlantic Beach Florida 32233 -5445 �" Phone (904) 247 -5826 • Fax (904) =-"r• .- • -* to 10. E -mail: building- dept @coab.us Date routed: 2 /1 City web -site: http: //www.coab.us APPLICATION REVIEW AND TRACKING FORM roperty Address: l %� , Department review required Yes No Building ✓ pplicant: • Planning & Zoning ✓ p Tree Administrator � Public Works roject: Public Utilities ' � Public Safety Fire Services ReVlrew.feew$ ° _ Dept Signatuee Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) ) Comments: BUILDING / PLANNING & ZONING Reviewed by: Date: tai - // TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ODenied. Comments: Reviewed by: Date: Revised 05/14/09 5 City of Atlantic Beach APPLICATION NUMBER � �s Building Department (To be assigned by the Building Department.) 800 Seminole Road / j ' Atlantic Beach, Florida 32233 -5445 // ^ / 7� Phone (904) 24,7 -5826 Fax (904) 247 -5845 n 91" E -mail: building- dept @coab.us Date routed: 7- // City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM L4(o Property Address: /qt( OZ. Department review required Yes No Building Applicant: Planning & Zoning Tree Administrator Project: Public Works Public Utilities Public Safety Fire Services 131 :7 15e13igrafur1 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: RtXpproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: 3 AIPS Date: ?• _2" TREE ADMIN. Second Review: Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 ,t r�� City of Atlantic Beach VED APPLICATION NUMBER o " , Building Department F EB 2 3 2011 ( To be assigned by the Building Department.) ... - A.. .. 8 00 Seminole Road Atlantic Beach, Florida 32233 -5445 if ^ /7/ Phone (904) 247 -5826 • Fax (904) - r it 93" E -mail: building- dept @coab.us Date routed: 2 7/ City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM roperty Address: � : , - - Oc • Department review required Yes No Building • pplicant: 094.• Planning & Zoning ✓ Tree Administrator roject: Public Works ./✓ Public Utilities Public Safety Fire Services k _r De t 81 ur �: r` Review fees$ . , . nat p S q Fv Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ['Denied. L (Circle one.) Comments: BUILDING PLANNING & ZONI Reviewed by: Date: TREE ADMIN. Second Review: DApproved as revised. ['Denied. pj_g,�•= Co mments: Of al UTI ITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 '� ' t, CITY OF ATLANTIC BEACH fy 800 SEMINOLE ROAD . ATLANTIC BEACH, FL 32233 t..),73f 41 INSPECTION PHONE LINE 247 -5826 A. t y Jf3a > 11- 00001712 Date 4/11/11 Application Number Property Address 1946 BEACHSIDE CT Application type description RESIDENTIAL ADDITION Property Zoning TO BE UPDATED Application valuation . . . • 10000 Application desc ADD 120 SF ADDITION TO DINING ROOM IN REAR OF HSE Owner Contractor POWERS SHIELA ANNE ALESCH CONTRACTING INC 1946 BEACHSIDE COURT 1946 BEACHSIDE CT ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 613 -6517 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type RESIDENTIAL Flood Zone ZONE X Permit ELECTRICAL PERMIT Additional desc . WIRE ADDITION Sub Contractor . ISLAND ELECTRIC OF THE FIRST C .00 Permit Fee . . . 62.20 Plan Check Fee . Issue Date Valuation . . . . 0 Expiration Date . . 10/08/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination in needed, call 247 -5834. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. Other Fees STATE ELEC DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 PERMIT I APPROVED ONLY IN ACCORDANCE WIT ALE tTI't U� A- N C BEA -CFI DIN Ned AND THE TEORII7�C BUILDINCESSummary Charged Paid I. �L�j , , CITY OF ATLANTIC BEACH r.) lkilk f y 800 SEMINOL �' 7 '• k j A BEACH, 32233 �3 INSPECTION PHONE LIN E Page 2 Date 4/11/11 11- 00001712 ---_______ Application Number - -_ -_ - _- ___ -___ ---- - --.o0 .00 _ --- - - - - -- 62.20 62.20 .00 .00 Permit Fee Total .00 .00 .00 .00 Plan Check Total 4.00 4.00 .00 .00 Grand Fee Total 66.20 66.20 Grand Total E z irrErrr rsaenzuvED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 a Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / f �i SW U 3iL I Cr- PERMIT # I g 1 " 1711 JEA INFORMATION REQUIRED ON ALL PERMITS 2O 0 AMPS IzU %%VOLTS / PHASE VALUE OF WORKS 1, a, 0 NEW SERVICE ❑ Overhead n Underground ❑J Underground up Pole ❑ Residential (Main) Service 0 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Meters ❑ Commercial (Main) Service ❑ - 100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps ❑ CT Service amps Conductor Type Size ❑ Multi- Family (Main) Service 0 0 - 100 amps ❑ 101 150amps ❑ 151 200amps ❑ amps # of Unit Meters [1] Temporary Pole ❑ amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.) 11100 amps ❑ 150amps 0 200amps ❑ amps 0 C Service amps ADDITIONS, REMODELS, REPAIRS, BUILD - OUTS, ACCESSORY STRUCTURES, ETC. Outlets /Switches: IS 0- 30amps 31- 100amps 101- 200amps Appliances: 0- 30amps 31- 100amps 101- 200amps A/C Circuits: 0- 60amps 61- 100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: I t OTHER ELECTRICAL PROJECTS ❑ Swimming Pool ❑ Sign ❑ Smoke Detectors _ Qty ❑ Transformers KVA ❑ Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts /amps VALUE OF WORK $ REPAIRS/MISCELLANEOUS ❑ Replace Burnt/Damaged Meter Can ❑ Safety Inspection ❑ Panel Change ❑ OH to UG ❑ Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 1 '4 /.-.Ste. H Phone Number 44S * 62 i 7 Electrical Company 15 t. A 1 -- 1 - (2CTt i G Office Phone 2 -'t -4,0 65" Fax 2'(& " To 7C Co. Address: 6, 21/ S3.1 xi - Cit JAS- & i4 . State R- Zip 327 Sl? License Holder (Print): J01 Ni R . gze State Certification/Registration # Fla 130 (3jSlo Notarize , 7:, . _ _; • - ,x.:. - . :,'.,:44 old , )alLa�%% J- z�C1 � . .. ..t v: a A. WHITE I , :. MY COMMISSION # D(, C34s 8wi r and subscribed before Ale 'is � 4- da of i 20 -sue: o: EES: May 21 �! r' + � � ' Pf gty �`, Bonded Thru XPIR Notar Public Uf'Ger4 11 , , / - - - -- �---, . ature of Notary Public -.1,,A a --0 dd--d /