Loading...
Permit 53 lewis St (vault folder) FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JACK1159 Builder Name: Jacksonville Homes Street: 53 Lewis Street Permit Office: City of Jacksonville City,State,Zip: Jacksonville, FL, Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1336.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=11.0 1072.00 ft2 b. Face Brick-Wood, Exterior R=11.0 264.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1508.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1508.00 ft2 6. Conditioned floor area above grade(ft2) 1442 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 7. Windows(90.0 sqft.) Description Area a. Sup:Attic, Ret:Attic,AH: RoomslnBlockl 6 258 a. U-Factor: Dbl, U=0.54 90.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 30.0 SEER:13.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 30.0 HSPF:7.70 SHGC: Area Weighted Average Overhang Depth: 1.667 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap:40 gallons 8. Floor Types (1442.0 sqft.) Insulation Area EF:0.950 a. Slab-On-Grade Edge Insulation R=0.0 1442.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 28.31 PASS Glass/Floor Area: 0.062 Total Standard Reference Loads: 37.51 I hereby certify that the plans and specifications covered by Review of the plans and ; 0 O ZKE STAT •:,,� this calculation are in co pliance ' h the Flo da Ener y specifications covered by this v ;� O Code. ✓ � calculation indicates compliance £c, •',., :`,kit',.--,4•2:..; ,• , ---eLdi with the Florida Energy Code. • L + ^,tai, ' ^ ^ti 0 PREPARED BY: OU S I�.§tickles Before construction is completed F - t` DATE: �!�/3a /� this building will be inspected for compliance with Section 553.908 r Florida Statutes. k I t� ?� I hereby certify that this building, as sig ed, is in compliance '��'C •.... , '�5 ., with the Florida Ener ..Ob wt ,-..0- OWNER/AGENT: BUILDING OFFICIAL: DATE: G - Z - 12 DATE: 6---5,--w___ - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist �,Y,.........:...,.,�..�.-.rte• „: FIDE COPY] 5/30/2012 11:01 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 53 Lewis Street PERMIT#: Jacksonville, FL, MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors &outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 5/30/2012 11:01 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: JACK1159 Builder Name: Jacksonville Homes Street: 53 Lewis Street Permit Office: City of Jacksonville City,State,Zip: Jacksonville , FL, Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: JACK1159 Bedrooms: 4 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 1442 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Jacksonville Homes Rotate Angle: 0 Street: 53 Lewis Street Permit Office: City of Jacksonville Cross Ventilation: County: Duval Jurisdiction: 261300 Whole House Fan: City, State,Zip: Jacksonville, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1442 12000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 RoomslnBlockl 1442 12000 Yes 4 4 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio RoomslnBlockl 167 ft 0 1442 ft2 ____ 0.25 0 0.75 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1562 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1442 ft2 N N CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) RoomslnBlockl 30 1508 ft2 0.11 Wood 5/30/2012 11:01 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Absor Grade% 1 N Exterior Frame-Wood RoomslnBloc 11 27 8 216 ft2 0 0.4 0 2 E Exterior Frame-Wood RoomslnBloc 11 50 6 8 404 ft2 0 0.4 0 3 S Exterior Face Brick-Wood RoomslnBloc 11 13 9 8 110 ft2 0 0 0.4 0 4 E Exterior Face Brick-Wood RoomslnBloc 11 6 8 48 ft2 0 0 0.4 0 5 S Exterior Face Brick-Wood RoomslnBloc 11 13 3 8 106 ft2 0 0 0.4 0 6 W Exterior Frame-Wood RoomslnBloc 11 56 6 8 452 ft2 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated RoomslnBloc None 0.460000 3 6 8 20 ft2 2 W Insulated RoomslnBloc None 0.460000 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.54 0.3 N 15 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 2 E 2 Metal Low-E Double Yes 0.54 0.3 N 45 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 3 S 3 Metal Low-E Double Yes 0.54 0.3 N 15 ft2 5 ft 0 in 1 ft 0 in HERS 2006 None 4 S 5 Metal Low-E Double Yes 0.54 0.3 N 15 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 1361.6 74.753 140.58 0.2771 6.8083 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:7.7 30 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 13 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None RoomslnBlock0.95 40 gal 70 gal 120 deg None 5/30/2012 11:01 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- Return---- Air Percent HVAC# V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 258 ft2 Attic 72.1 ft2 DSE=0.88 RoomslnBl 0.0 cfm 0.00% 0.00 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [X]Jan [X]Feb [X]Mar [X]Apr [X1 May [X]Jun [X]Jul [X]Aug [X]Sep [X]Oct [X]Nov [X]Dec Heating X Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov X Dec Venting X Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct ki Nov ki Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit 5/30/2012 11:01 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 75 The lower the EnergyPerformance Index, the more efficient the home. 53 Lewis Street, Jacksonville, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=11.0 1072.00 ft2 b. Face Brick-Wood, Exterior R=11.0 264.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 1508.00 ft2 6. Conditioned floor area(ft2) 1442 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 11. Ducts R ft2 a. U-Factor: Dbl, U=0.54 90.00 ft2 a. Sup:Attic, Ret:Attic,AH: RoomslnBlockl 6 258 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 30.0 SEER:13.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 30.0 HSPF:7.70 Area Weighted Average Overhang Depth: 1.667 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap:40 gallons a. Slab-On-Grade Edge Insulation R=0.0 1442.00 ft2 a. Electric EF: 0.95 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building { ;,©�liesti .ry.«r Construction through the above energy saving features which will be installed (or exceeded) ' o in this home before final inspection. Otherwise, a new EPL Display Card will be completed �`'i,,,,`'', ' ,�.. . o based on installed Code complia res. L Builder Signature: Date: L, ' -5 -( `Z �'• e 2 . Address of New Home: .-.---6.-.---6 �•S City/FL Zip: �� Cc 4,G .' , .' ` f.J�� = 00 if I *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Pro ect SummaryJob: SHAY1159 4 wrightsoft"' 1Date: Entire House By: DRS ShayCore Enterprises, Inc. 4230 Pablo Professional Court,Suite#110,Jacksonville,FL 32224 Phone:904-992-4405 Fax:904-992-4410 Pro'ect Information For: Jacksonville Homes, LLC. 1794 Rogero Road, Suite#1002, Jacksonville, FL 32221 Phone: 904-744-4755 Fax: 866-329-6692 Notes: 53 Lewis Street Desi• n Information Weather: Jacksonville, Intl Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 22085 Btuh Structure 16735 Btuh Ducts 5233 Btuh Ducts 6565 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27318 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 22834 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2502 Btuh Ducts 1404 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1442 1442 Equipment latent load 3906 Btuh Volume(ft') 11536 11536 Air changes/hour 0.45 0.23 Equipment total load 26741 Btuh Equiv.AVF (cfm) 87 44 Req. total capacity at 0.74 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC330(A,W)**30 Cond 25HBC330(A,W)**30 AHRI ref no.3699497 Coil FB4CNF030 AH RI ref no.3699497 Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 22200 Btuh Heating output 30000 Btuh @ 47°F Latent cooling 7800 Btuh Temperature rise 27 °F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-May-30 11:12:20 1 " Wrightsoft° Right-Suite®Universal 2012 12.0.07 RSU13256 Page 1 ACCA E:\Jacksonville Homes\JACK1159.rup Calc=MJ8 Front Door faces: S 4 wrightsok Right-J® Worksheet Job: SHAY1159 Entire House Date: By: DRS ShayCore Enterprises, Inc. 4230 Pablo Professional Court,Suite#110,Jacksonville,FL 32224 Phone:904-992-4405 Fax:904-992-4410 1 Room name Entire House Main House 2 Exposed wall 167.0 ft 167.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 1442.0 x 1.0 ft 5 Room area 1442.0 ft2 1442.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ULlI- 12B-Osw 0.097 n 3.69 2.74 216 201 741 550 216 201 741 550 C 3A-2ob 0.610 n 23.18 23.63 15 0 348 354 15 0 348 354 12B-Osw 0.097 e 3.69 2.74 404 359 1323 982 404 359 1323 982 3A-2ob 0.610 e 23.18 79.49 45 0 1043 3577 45 0 1043 3577 11 W 12B-0bw 0.097 e 3.69 1.63 48 48 177 78 48 48 177 78 12B-Obw 0.097 s 3.69 1.63 216 166 612 271 216 166 612 271 3A-2ob 0.610 s 23.18 38.32 30 1 695 1150 30 0 695 1150 11J0 0.600 s 22.80 18.36 20 20 456 367 20 20 456 367 WI 128-0sw 0.097 w 3.69 2.74 452 432 1592 1182 452 432 1592 1182 D 11J0 0.600 w 22.80 18.36 20 20 456 367 20 20 456 367 C 16B-21ad 0.044 w 1.67 2.38 1442 1442 2411 3433 1442 1442 2411 3433 F 22A-tph 1.358 w 51.60 0.00 1442 167 8618 0 1442 167 8618 0 6 c)AED excursion 0 0 Envelope loss/gain 18472 12310 18472 12310 12 a) Infiltration 3613 875 3613 875 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 5 1150 Appliances/other 2400 2400 Subtotal(lines 6 to 13) 22085 16735 22085 16735 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22085 16735 22085 16735 15 Duct loads 24% 39% 5233 6565 24% 39% 5233 6565 Total room load 27318 23300 27318 23300 Air required(cfm) 1000 1000 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr- htsoft` 2012-May-3011:12:20 9 Right-Suite®Universal 2012 12.0.07 RSU13256 Page 1 i4G \ E:\Jaclksonville Homes\JACK1159.rup Calc=MJ8 Frort Door faces: S wrightsoft Building Analysis Date: SHAY1159 Entire House By: DRS ShayCore Enterprises, Inc. 4230 Pablo Professional Court,Suite#110,Jacksonville,FL 32224 Phone:904-992-4405 Fax:904-992-4410 Pro'ect Information For: Jacksonville Homes, LLC. 1794 Rogero Road, Suite#1002, Jacksonville, FL 32221 Phone: 904-744-4755 Fax: 866-329-6692 Desi• n Conditions Location: Indoor: Heating Cooling Jacksonville, Intl Airport, FL, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 38 18 Latitude: 31°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 11.5 50.0 Dry bulb(°F) 32 93 Infiltration: Daily rang °F) - 18 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh % of load Walls 3.7 4445 16.3 VVall Duffs Glazing 23.2 2086 7.6 Doors 22.8 912 3.3 Ceilings 1.7 2411 8.8 Gm""°_________________ Floors 6.0 8618 31.5 ° s,tr,�n Infiltration 2.7 3613 13.2 Ducts 5233 19.2 °,� , Piping 0 0 Humidification 0 0 Ventilation 0 0 Floors Adjustments 0 Total 27318 100.0 Coolin• Component Btuh/ft2 Btuh % of load Walls 2.5 3062 13.1 walls Internal Gains Glazing 56.5 5081 21.8 Doors 18.4 734 3.2 Ceilings 2.4 3433 14.7 Floors 0 0 0 Infiltration 0.7 875 3.8 Glazing_ Ducts 6565 28.2 Ventilation 0 0 Ducts Internal gains 3550 15.2 Blower 0 0 Dors Adjustments 0 Total 23300 100.0 Ceilings/ Infiltration Latent Cooling Load = 3906 Btuh Overall U-value= 0.115 Btuh/ft2-°F Data entries checked. 2012-May-30 11:12:20 „` -41- wrightsoft" Right-Suite®Universal 2012 12.0.07 RSU13256 Page 1 RCCA E:\Jacksonville Homes\JACK1159.rup Calc=MJ8 Front Door faces: S