Loading...
Permit Remodel Carriage House 631 Beach 2011 ► 'L�l te> CITY OF ATLANTIC BEACH s 1 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 - ` .4 0,111 914 Application Number 11- 00001809 Date 3/28/11 Property Address 631 BEACH AVE Application type description RESIDENTIAL ALTERATION Property Zoning TO BE UPDATED Application valuation . . . 125000 Application desc renovations to carriage house Owner Contractor HUGHES SATILLA INC 631 BEACH AVENUE 2742 HERSCHEL STREET ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32205 (904) 389 -3704 Permit RESIDETNIAL ALT /OTHER Additional desc . Permit Fee . . . 555.00 Plan Check Fee . . 277.50 Issue Date . . . Valuation . . . . 125000 Expiration Date . 9/24/11 Special Notes and Comments Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247 -5834. Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE DCA SURCHARGE 8.33 DEV REVIEW - SINGLE & 2 -FAM 25.00 ENG REV PRE APP > 3 HRS 25.00 STATE DBPR SURCHARGE 8.33 UTIL REV PRE APP >3 HRS 25.00 BUPERLDINGMIT IN ACCORDAN �Ij�LL CITY OF A�L {IC BEACH QRDID'iN AND THE FLORIDA 6 .. �'� CITY OF ATLANTIC BEACH i 800 SEMINOLE ROAD r' ! ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 11- 00001809 Date 4/18/11 Application Number Property Address 631 BEACH AVE Application type description RESIDENTIAL ALTERATION Property Zoning TO BE UPDATED Application valuation . . . • 125000 Application desc renovations to carriage house Owner Contractor HUGHES SATILLA INC 631 BEACH AVENUE 2742 HERSCHEL STREET ATLANTIC BEACH FL 32233 A K O 389-3704 FL 32205 Permit ELECTRICAL PERMIT Additional desc . Sub Contractor . UNITED ELECTRIC COMPANY OF .00 Permit Fee . . . • 104.00 Plan Check Fee . . Issue Date . . . • Valuation . . . . 0 Expiration Date . . 10/15/11 Special Notes and Comments Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247 -5834. Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE ELEC DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ' � e CITY OF ATLANTIC BEACH ::_, :+ 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 ` ' Page 2 Application Number . . . . . 11- 00001809 Date 4/18/11 Permit Fee Total 104.00 104.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 108.00 108.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION J- - R,09 CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 I t /�� Ph (904) 247 -5826 Fax (904) 247 -5845 ca JOB ADDRESS: o 3 } �, e_ c- (-: v„.._ i^ A v PERMIT # 11 - 1 l JEA INFORMATION REQUIRED ON ALL PERMITS U 0 AMPS 0 Li i� VOLTS / t PHASE ,VALUE OF WORK$ 6too,��o N(A NEW SERVICE El Overhead ❑ Underground ❑T Underground up Pole ❑Residential (Main) Service 0 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Meters ❑Commercial (Main) Service 00 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps OCT Service amps Conductor Type Size ❑Multi- Family (Main) Service 00 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Unit Meters ❑Temporary Pole ❑ amps ' SERVICE UPGRADE / ❑ amps ❑ CT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.) N A ❑ 100 amps ❑ 150amps ❑ 200amps ❑ amps ❑ CT Service amps ADDITIONS, REMODELS, REPAIRS, BUILD -OUTS, ACCESSORY STRUCTURES, ETC. Outlets/Switches: 7 0 0- 30amps 31- 100amps 101- 200amps Appliances: 3 0- 30amps 1 31- 100amps 101- 200amps A/C Circuits: I 0- 60amps 61- 100amps Heat Circuits: I # circuits @ 5 kw Number of Lighting Outlets, Including Fixtures: :2 3 O'T'HER ELECTRICAL PROJECTS ❑Swimming Pool ❑ Sign %Smoke Detectors 1 Qty ❑Transformers KVA ❑Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts /amps VALUE OF WORK $ REPAIRS/MISCELLANEOUS OReplace Burnt/Damaged Meter Can ❑ Safety Inspection Panel Change ❑ OH to UG ❑ Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ` e S (�e .3 Phone Number 5 3 _. 7 9 5 ` j 0 r 3 Phone - / - (/°?/ Fax 73/ 3 1/ Electrical Company \.A1), t" � C ! � c� � , Z Go Office �.s , n ✓( State FL Zip 3; Co. Address: 5 1 1 Le .5 }' � `y'' � � City � � � � P License Holder (Print): ()oil ii n E. 41-1/17,A, (Iv State Certification/Registration # E C- 0 (Po 3 Y `/ • a��ah�.n_vf I ieer_c Holder ,1 ( il f yrt' -`2's GEORGE BOWER JEFFRIES, JR. v i* , , 4 MY COMMISSION # DD 813331 , Sworn and subscribed before me this 15 1 day of 19 t' 1 20 h "-:. % - EXPIRES: December 10, 2012 , - Thai Notary Public Undo/wawa Signature of Notary Public _ -- _ d`_ .. � ,,-� 0i /.- /r j'ilj s , ;` CITY OF ATLANTIC BEACH :,,, 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 .4J331 Page 2 Application Number 11- 00001809 Date 3/28/11 Permit Fee Total 555.00 555.00 .00 .00 Plan Check Total 277.50 277.50 .00 .00 Other Fee Total 91.66 91.66 .00 .00 Grand Total 924.16 924.16 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247 -5826 Fax (904) 247 -5845 Job Address: 10 I b-r2 e h it ve.- 11416.114 c • &O'1 FL- Permit Number: // — 11?'0 ? Legal Description LOT 2 , 01k 31 4'fl , al IV. R., Parcel # I'70I 1 3--- 0000 i F Area of Sq.Ft. Sq.Ft Valuation of Work $ / 2 ! f Q /1 Proposed Work heated /cooled 19,50 non- heated /cooled Class of Work (circle one): New Addition _fiferatioi) Repair Move Demolition pool /spa window /door Use of existing /proposed structure(s) (circle one): Commercial ' eside s ��� If an existing structure, is a fire sprinkler system installed? (Circle one): • es C=.:o N / • Florida Product Approval # For multiple products use product approval form / LS (�" owl ift U De ribe in detail the type o ork to be performed: L.'` 0 ` ■ A L / , _ _ CS Irk II 8 Q Q4 d A • - —' 8 2011 flI .y El Property Owner I : rmation: I '� Name: ,iiife5 A. f Susan }Ughe6 , r� Address: Mg RQ.('eflcc Roctti City ?je The 5 d& StateP1 Zip ZZO5il Phone 5u.5.- l-tv .3 , G! lb Z - Write E -Mail or Fax # (Optional) 5W ' a hu9he5 ?4 o44-. ne+ Contractor Information: Company Name: 3O. l I a i d41t Qualifying Agent: UdQ.1l1 ' e% V11Q.1 ,r� (6044) Address: 8449, i- }er5Me1 51-r e:r City t,. +`iv�1 State FL - Zip 3LZc'S Office Phone Cc f 3 ?Li - 3r/DL{ Job Site/ Contact Number got - s oq - 149 Fax # r - 3s-q - in 1'7 State Certification /Registration # e 6 C 12 3 "► $ v �^' ' �� . Architect Name & Phone # clY'. ■ Iu...e.h 1 r fe.1- Cett.(SC. CA- 'i3- 5 5 111101r Engineer's Name & Phone # • . "on-4-i • o s ; 4 � _ .C:. rxt •-, ♦ ©y - 2 2 - i og MINNI !;: ` Fee Simple Title Holder Name and Address . ' Bonding Company Name and Address v s ; ' g P Y � 1���. ■ ,� ;r►� i Sri i a c i ;a �� i � a�, : �� Mortgage Lender Name and Address . �„ e .. i ,�� itt :; �.i CITY OF AT lC ° ' Application is hereby made to obtain a permit to do the work and in .nations as i• .o z.. ,�:: . r�q a • • ion has co e to. Ii issuance of a permit and that all work will be performed to meet the . ndards of . i v . • ' diction Thi I p it ces w 4 if and void work is not commenced within six (6) months, or if const non or w ' • . ,: N ., r ,' b , �, o p 4 e � (s, • •. six (6) ms , t s -:'t .. , • y work is commenced. I understand that separate permits must be s: ured for Electrica Work, Plumbing, igns, 'le s, 'ools, Furna , g, '4iilure.: . a t Tanks and Air Conditioners, etc. REVIEWED WED BY. ' 3 3 DATE: 3 J / ! r 1 WARNING TO OWN YO _ -- •- -_ - - - - - - -- '-- - - - -'1 COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROV ~ mtNts j TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 1 hereby certify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to viol. or cancel the a provisions of other federal, state, or local law regulating construction a; the performance of construction. // Signature of Owner �' Signature of Contracto /' Print Name J S 4N.( I"b-c_f14 1 -} S Print Nam rid VJ & r5 ;r , Sworn t• and +su cr befo e ,- Swe n t and subscr'.ed before Ap this Dad £ r ' 0 ,f thi. 1; D.1of /, / 20/ r: , t.. .i •, M Y COMMISSION ik DO 747923 .� ' , , ; a n p n 74 . A. Notary iblic j r r No � ;✓ ,RFS Ja n �y �s, 2o�� EXPIRES: January 13 2012 ,..s Bonded Tin NOhtyPublic Underwdten �F;; — Brn , iThruNotary tublicUndanvrrte•s ed 01.26.10 DO NOT VITRITF, BELOW - OFFICE USE ONLY )plicable Codes: 2007 Florida Building Code wl 2009 Revisions eview Result (circle one) : pproved Disapproved Approved w/ Conditions eview Tnitials/Date: .,. 3 ; / levelopmment Size fabitable Space / 90 s Non- Habitable Impervious area 'adon/D CA/DBPR$ Miscellaneous Info rmation_ )ccupancy Group e ype of Construction V (3 Number of Stories 2. .. honing District p - _ vlax. Occupancy Load Fire Sprinklers Required ►v' Flood Zone Conditions /Comments: Satilla, Inc. 27+2 Herschel Street, Jacksonville, FL 32205 Telephone: 904.389.3704 rax: 904.389.7817 March 16, 2011 RE: 631 Beach Avenue Atlantic Beach, FL 32233 To Whom It May Concern: I hereby appoint Satilla, Inc and Brad Walters as my agent in all matters related to the acquisition of a building permit and /or any documents relating to the construction of the improvements located at 631 Beach Avenue. 3 1. 1 Susan Hughes (Owner) Date: 3/7/// Brad Walters of Satilla, Inc. (Contractor) Date: The foregoing instrumerA was acknowledged before me this / '7 day of / A& 2011, by ,`-uSC'. -r\ .�►.e (Owner) and -jY4. V✓O.J4ers as Agent for g i t 5 G� 11 Prz-4_ c a (Owner) in Duval County, Florida. itto? Ott,A Notaryr. Print Name 1 h JL, trYt \1 Date: My Commission E *__ 1 : „��;�,, CHR�Y V. CARROLL -,;' .;: MY COMMISSION # DD 747923 Rfui`�' ` Bonded I T ru Notary January 13, Underwriters FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Hughes Carria a House Builder Name: 131 &A LJ .p., 1r �- Street: 45 1 C . C °r " ] i t , Permit Office: Atlantic Beach City, State, Zip: lantic eac FL , ` Permit Number: Owner: r‹D Jurisdiction: 261100 Design Location: , Jac sonville 1. New construction or existing New (From Plans) 9. Wall Types (1699.2 sqft.) Insulation Area 2. Single family or multiple family Single - family a. Frame - Wood, Exterior R =11.0 1505.60 ft b. Frame - Wood, Adjacent R =11.0 193.60 ft 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 1 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types (1168.0 sqft.) Insulation Area 6. Conditioned floor area (ft 1290 a. Under Attic (Unvented) R =1.0 1168.00 ft b. N/A R= ft 7. Windows(158.5 sqft.) Description Area c. N/A R= ft a. U- Factor: Dbl, default 158.50 ft SHGC: Clear, default 11. Ducts b. U- Factor: N/A ft2 a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 167.7 ft SHGC: 12. Cooling systems c. U- Factor: N/A ft a. Central Unit Cap: 30.0 kBtu /hr SHGC: SEER: 14 d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.0 kBtu /hr e. U- Factor: N/A ft2 HSPF: 8.1 SHGC: 14. Hot water systems 8. Floor Types (1007.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Floor over Garage R =19.0 636.00 ft2 EF: 0.92 b. Slab -On -Grade Edge Insulation R =0.0 371.00 ft2 b. Conservation features c. N/A R= ft2 None 15. Credits None Glass /Floor Area: 0.123 Total As -Built Modified Loads: 28.96 PASS Total Baseline Loads: 34.66 I hereby certify that the plans and specifications covered by Review of the plans and ``` E S7 ,47 .4 this calculation are in compliance with the Florida Energy specifications covered by this �� �a � �. Code. �Q,11„J calculation indicates compliance y ' „ , a As v, 4, ti with the Florida Energy Code. a ; � , PREPARED BY J e Ell iS_ Before construction is completed x is 73 DATE: 3.1-it this bu will be inspected for t ., f' compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 4, ?; ,, 5 ' with the Florida Ener. Code. �Lf,, OWNER /AG T: , . ■ ∎ BUILDING OFFICIAL: rn P"' DATE: .‹ f . - DATE: 3/93/ 1/ 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 1 of 5 , FORM 1100A -08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Hughes Carriwe House Builder Name: 0,4 t,kc-L "lc -e',,, Street: �p 51 i Permit Office: Atlantic Beach City, State, Zip: Atl�nti , FL , Permit Number: Owner: Jurisdiction: 261100 Design Location: FL, Jacksonville 1. New construction or existing New (From Plans) 9. Wall Types (1699.2 sqft.) Insulation Area 2. Single family or multiple family Single- family a. Frame - Wood, Exterior R =11.0 1505.60 ft b. Frame - Wood, Adjacent R =11.0 193.60 ft 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 1 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types (1168.0 sqft.) Insulation Area 6. Conditioned floor area (ft 1290 a. Under Attic (Unvented) R =1.0 1168.00 ft b. N/A R= ft 7. Windows(158.5 sqft.) Description Area c. N/A R= ft a. U- Factor: Dbl, default 158.50 ft SHGC: Clear, default 11. Ducts b. U- Factor: N/A ft2 a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 167.7 ft SHGC: 12. Cooling systems c. U- Factor: N/A ft a. Central Unit Cap: 30.0 kBtu /hr SHGC: SEER: 14 d. U- Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.0 kBtu /hr e. U- Factor: N/A ft2 HSPF:8.1 SHGC: 14. Hot water systems 8. Floor Types (1007.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Floor over Garage R =19.0 636.00 ft2 EF: 0.92 b. Slab -On -Grade Edge Insulation R =0.0 371.00 ft2 b. Conservation features c. N/A R= ft2 None 15. Credits None Glass /Floor Area: 0.123 Total As -Built Modified Loads: 28.96 PASS Total Baseline Loads: 34.66 I hereby certify that the plans and specifications covered by Review of the plans and d T this calculation are in compliance with the Florida Energy specifications covered by this r/ ,'� ` 'N,Q.\ • Code calculation indicates compliance '� r, '� ``, �; with the Florida Energy Code. : t 1= d' - : ' , „ PREPARED BY l"'1 r� 3L El 5 Before construction is completed . '. , `� 73 DATE: 3 ` (• (t this build will be inspected for 0 , .):• compliance with Section 553.908 * „ . , i I hereby certify that this building, as designed, is in compliance Florida Statutes. 1 _� ,,, with the Florida Ener• Code. . C a b WE OWNER /AGEN • - . . - • ` � , - BUILDING OFFICIAL: DATE: l I - -- DATE: 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 1 of 5 t PROJECT Title: Hughes Carriage House Bedrooms: 1 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 1290 Lot* Owner: Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City, State, Zip: Atlantic Beach , Family Type: Single- family FL , New /Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Jacksonville FL_JACKSONVILLE_INT 2 32 93 75 70 1281 49 Medium FLOORS V # Floor Type Perimeter Perimeter R -Value Area Joist R -Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation 75.8 ft 0 371 ft 0 0 1 2 Floor over Garage 636 ft 19 0 0 1 ROOF V Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 1064 ft 0 ft Medium 0.96 No 19 30.3 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 919 ft N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 1 1168 ft 0.11 Wood WALLS — Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R -Value Area R -Value Fraction Absor. 1 E Exterior Frame - Wood 11 413.6000 0.23 0.75 2 N Garage Frame - Wood 11 193.6000 0.23 0.01 3 W Exterior Frame - Wood 11 413.6000 0.23 0.75 4 S Exterior Frame - Wood 11 436 ft 0.23 0.75 5 N Exterior Frame - Wood 11 242.3999 0.23 0.75 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 2 of 5 DOORS V # Ornt Door Type Storms U -Value Area 1 N Wood None 0.460000 18.89999 2 N Wood None 0.460000 18.89999 3 E Wood None 0.460000 8.75 ft 4 E Wood None 0.460000 8.75 ft 5 E Wood None 0.460000 21 ft WINDOWS Orientation shown is the entered, asBuilt orientation. Overhang _ __ # Ornt Frame Panes NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening 1 E Metal Double (Clear) No 0.87 0.66 N 8 ft 2 ft 0 in 15 ft 0 in HERS 2006 None 2 E Metal Double (Clear) No 0.87 0.66 N 17.5 ft 8 ft 0 in 1 ft 0 in HERS 2006 None 3 S Metal Double (Clear) No 0.87 0.66 N 15 ft 11 ft 0 in 1 ft 0 in HERS 2006 None 4 E Metal Double (Clear) No 0.87 0.66 N 4 ft 2 ft 0 in 1 ft 0 in HERS 2006 None 5 N Metal Double (Clear) No 0.87 0.66 N 8 ft 2 ft 0 in 1 ft 0 in HERS 2006 None 6 W Metal Double (Clear) No 0.87 0.66 N 90 ft 2 ft 0 in 1 ft 0 in HERS 2006 None 7 S Metal Double (Clear) No 0.87 0.66 N 16 ft 2 ft 0 in 1 ft 0 in HERS 2006 None INFILTRATION & VENTING - - -- Forced Ventilation - - -- Run Time Fan V Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 1218 7.08 66.9 125.8 0 cfm 0 cfm 0 0 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 636 ft O ft 84.8 ft 8 ft 0 COOLING SYSTEM V # System Type _ Subtype Efficiency _ Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 14 30 kBtu /hr 900 cfm 0.75 sys #0 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 8.1 30 kBtu /hr sys #0 HOT WATER SYSTEM V _ # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 40 gal 120 deg None 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 3 of 5 SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V / - - -- Supply - - -- Return - - -- Air Percent # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Interior 6 167.7 ft Interior 64.5 ft Default Leakage Interior (Default) c (Default) % TEMPERATURES Programable Thermostat: None Ceiling Fans: Coolin X jaann X Mar X A o maa, X Jun X J 1 ul A u Oct Nov r(, Dec Venting �X� Jan �X� Feb Feb � X X� Mar �X� r Apr May € X � Jun �X� Jul XX J Aug �X� Sep Sep � X Oct � Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 4 of 5 } FORM 1100A -08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: PERMIT #: Atlantic Beach, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm /sq.ft. window area; .5 cfm /sq.ft. door area. Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows /doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top /bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the ✓ top plate. Floors N1106.AB.1.2 Penetrations /openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier _ is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. ✓ OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R -6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for J _ each system. Insulation N1104.AB.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both N1102.B.1.1 sides. Common ceiling & floors R -11. • 3/1/2011 8:25 AM EnergyGauge® USA - FlaRes2008 Page 5 of 5 S ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformance Index, the more efficient the home. , Atlantic Beach, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single - family a. Frame - Wood, Exterior R =11.0 1505.60 ft b. Frame - Wood, Adjacent R =11.0 193.60 ft 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 1 d. N/A R= ft 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft 1290 a. Under Attic (Unvented) R =1.0 1168.00 ft b. N/A R= ft 7. Windows`" Description Area c. N/A R= ft a. U- Factor: Dbl, default 158.50 ft SHGC: Clear, default 11. Ducts b. U- Factor: N/A ft2 a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 167.7 ft SHGC: 12. Cooling systems c. U- Factor: N/A ft a. Central Unit Cap: 30.0 kBtu /hr SHGC: SEER: 14 d. U- Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 30.0 kBtu /hr e. U- Factor: N/A ft HSPF: 8.1 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Floor over Garage R =19.0 636.00 ft2 EF: 0.92 b. Slab -On -Grade Edge Insulation R =0.0 371.00 ft2 b. Conservation features c. N/A R= ft2 None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) �, o' . , as a' \ 0 in this home before final inspection. Oth -rwise new EPL Display Card will be completed z'/ '/ _ 46 '`< based on installed Code ,- a lant fe -' . , 00- _ / �� _ ._ r Builder Signature: �� Date: �' �7 Cl c Address of New Home: 63 / i3 Atli , v " "'�- City /FL Zip:A r6 f-- , 3-22_3? ,jM ° y4 *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638 -1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the **Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section 82.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 4 Project Summary Job: wrightsoft' Date: 2/28/11 Entire House By: M. Ellis Energy Design Systems, Inc. Project Information For: Hughes Carriage House Atlantic Beach, FL Notes: Front door faces East. Desi • n Information Weather: Jacksonville, Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 94 °F Inside db 74 °F Inside db 74 °F Design TD 42 °F Design TD 20 °F Daily range M Relative humidity 50 % Moisture difference 51 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25076 Btuh Structure 24287 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (21 cfm) 953 Btuh Central vent (21 cfm) 454 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26029 Btuh Use manufacturer's data n Rate /swing multiplier 0.99 Infiltration Equipment sensible load 24493 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1775 Btuh Ducts 0 Btuh Heating Cooling Central vent (21 cfm) 717 Btuh Area (ft 1290 1290 Equipment latent load 2492 Btuh Volume (ft 10320 10320 Air changes /hour 0.45 0.23 Equipment total load 26985 Btuh Equiv. AVF (cfm) 77 40 Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond Coil Efficiency 0 HSPF Efficiency 0 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47 °F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1163 cfm Actual air flow 1163 cfm Air flow factor 0.046 cfm /Btuh Air flow factor 0.048 cfm /Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.91 Bold italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . , -44- wr Right -Suite Residential 6.0.119 RSR29784 2011 - Mar -01 08:31:53 ACCP. E: \EDS \Current \Residential Manual J\ Hughes Carriage House, Atlantic Beach.rrp Calc = MJ8 Orient Page 1 PRODUCT APPROVAL INFORMATION SHEET PROJECT NAME: HUGHES REMODEL Permit # // _ [ (l 0 / PROJECT ADDRESS: 631 BEACH AVENUE, ATLANTIC BEACH, FL 32233 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. Exterior Doors 1. Swinging Andersen Doors 400 Series Frenchwood DP +50 to -65 psf 109724 Hinged Patio Doors - Outswinq with Stormwatch Protection, FWO 6080 AP /PA with HPIR GLASS 400 Series Stormwatch Andersen Doors 400 Series Frenchwood DP +50 to -65 psf 109725 Gliding Door with Storm- watch Protection - Outswing, FW03180 AR LOW -E IR- FWO 6080AP 2. Sliding 3. Sectional 4. Rollup 5. Automatic 6. Other B. Windows 1. Single Hung 2. Horizontal slider 3. Casement 4. Double Hung PGT DH -560 WinGuard Vinyl Impact Resistant, Missile Level D (9.0 lb 7058.20 2x4 traveling at 50 f /s) Rating is H -R50 52.125x75 (act. window buck size) with1 /8 Annealed -air space- 5/16 Laminated Annealed Insulating Glass or stronger. 5. Fixed 6. Awning 7. Pass - through • 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other C. Panel Wall 1, Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain Walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. Roofing Products 1. Asphalt shingles Owens Corning Asphalt Roofing Shingles 10674.10 and Starters 2. Underlayments Owens Corning WeatherLock Specialty Tile 13029.10 and Metal Self- adhering roof underlayment, 3 -tab • laminated, starter and hip & ridge 3. Roofing fasteners 4. Nonstructural metal roof 5. Built -up roofing 6. Modified Bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles /shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement - adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. Shutters 1. Accordian 2. Bahama 3. Storm panels PRODUCT APPROVAL INFORMATION SHEET PROJECT NAME: HUGHES REMODEL Permit# PROJECT ADDRESS: 631 BEACH AVENUE, ATLANTIC BEACH, FL 32233 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. Exterior Doors 1. Swinging Andersen Doors 400 Series Frenchwood DP +50 to -65 psf 109724 Hinged Patio Doors- Outswing with Stormwatch Protection, FWO 6080 AP /PA with HPIR GLASS 400 Series Stormwatch Andersen Doors 400 Series Frenchwood DP +50 to -65 psf 109725 Gliding Door with Stom1- watch Protection - Outswing, FW03180 AR LOW -E IR- FWO 6080AP 2. Sliding 3. Sectional 4. Rollup 5. Automatic 6. Other B. Windows 1. Single Hung 2. Horizontal slider 3. Casement 4. Double Hung PGT DH -560 WinGuard Vinyl Impact Resistant, Missile Level D (9.0 lb 7058.20 2x4 traveling at 50 f /s) Rating is H -R50 52.125x75 (act. window buck size) withl /8 Annealed -air space- 5/16 Laminated Annealed Insulating Glass or stronger. 5. Fixed 6. Awning 7. Pass - through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other C. Panel Wall 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain Walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. Roofinq Products 1. Asphalt shingles Owens Corning Asphalt Roofing Shingles 10674.10 and Starters 2. Underlayments Owens Corninq WeatherLock Specialty Tile 13029.10 and Metal Self- adhering • roof underlayment, 3 -tab laminated, starter and hip & ridge 3. Roofinq fasteners 4. Nonstructural metal roof 5. Built -up roofing 6. Modified Bitumen 7. Single ply roofing 8. Roofinq tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles /shakes 12. Roofinq slate 13. Liquid applied roofing 14. Cement - adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. Shutters 1. Accordian 2. Bahama 3. Storm panels 4. Colonial 5. Roll -up 6. Equipment 7. Other F. Structural Components 1. Wood connector /anchor A 35 Simpson Stronptie Framing Anchor ABU 66 Simpson Stronptie Adjustable Post Base 10446.4 CS 16 Simpson Stronptie Coiled Strap 108421 H 2.5T Simpson Stronptie Hurricane Tie 11852.1 H3 Simpson Stronptie Hurricane To 11478.3 LUS 210 Simpson Stronptie Joist Hanger 10456.13 LUS 210 -2 Simpson Stronptie Joist Hanger 10655.106 LUS 28 Simpson Stronptie Joist Hanger 10655.107 MSTA 24 Simpson Stronptie Strap Tie 10655.113 MSTA 48 Simpson Stronptie Strap Tie 10852.9 13872.2 2. Truss plates 3. Engineered Lumber 4. Railing 5. Coolers- freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck -roof 11. Wall 12. Sheds 13. Other G. Skylights 1. Skylight 2. Other H. New Exterior Envelope Products 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, it is the Contractors or Authorized Agents responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected. they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent. (Contractor or Design Professional) Brad Walters Satilla, Inc. Date 2742 Herschel Street Jacksonville, FL 32205 ph: 904.389.3704 fax: 904.389.7817 Erad;esalillainc.corn r i ., City of Atlantic Beach ��\ APPLICATION NUMBER 6 Building Department k9 (To be assigned by the Building Department.) r 1 800 Seminole Road \ 7 / � e ,,r Atlantic Beach, Florida 32233 -5445 N'J , °' Phone (904) 247 -5826 • Fax (904) 247 -5845 a �„r ;i �r E -mail: building- dept @coab.us Date routed: rl City web -site: http: / /www.coab.us ` APPLICATION REVIEW AND TRACKING FORM Property Address: 1 J 25 ' h 4 .1/- ' - * - ' nt review required Ye No l - _:,..•11.1 77 Applicant: c5/9 ��a.- /,ve. _ Planning & • ing / �} re- trator Project: Z'Ain li!'v7� O )S • 0 C.; m' -r'li. / ' . •lic Utilities ie SL e y Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPyCATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: Date: /r 3)// TREE ADMIN. Second Review: ❑Approved as revised. ❑De Qed. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 ! �x City of Atlantic Beach /). APPLICATION NUMBER Building Department 44# (To be assigned by the Building Department.) r �:. ' 800 Seminole Road Atlantic Beach, Florida 32233-5445 44 4 - f lr -- Phone (904) 247 -5826 • Fax (904) 247 - '". 9r E -mail: building- dept @coab.us Date routed: City web -site: http:!/www.coab.us APPLICATION REVIEW AND TRACKING FORM /f Property Address: /Ali &ti.14 i1 / I - ent review required Yes No 1 rw� Applicant: ,6/? /I LL / ,v . Planning & • ing • -- • • • trator Project: it/ 0_40 .. 1 - 0 �Af r'l� i • - • lic Utilities • - - Fire Services Review fee $ D5:07.) Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING p PLANNING & ZONING Reviewed by: de Date: A 9h TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 a y ^ M AR it 2 2011 ,o,A, ,.,, City of Atlantic Beach 8Y : ` , APPLICATION NUMBER �g j ' Building Department -�_ (To be assigned by the Building Department.) rV v 800 Seminole Road j�� ; Atlantic Beach, Florida 32233 -5445 f , � Phone (904) 247 -5826 • Fax (904) 247 -5845 � E-mail: building- dept @coab.us Date / J � City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: (, 15 4/j r L. review re. uired Yes No Applicant: „51q - 4 //et__ /AIL 4 Planning & • mg / re-__, trator � - Project: TZ a D '10 eAi rd., i9 F.e : l immim _ A le _5 L.,- 9 rr ... Fire Services _- Review fee $ Dept Signature , g° . , g ( 96 ' Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING diglik -. PLANNING & ZONING Reviewed by: Date: Lig- / / TREE ADMIN. Second Review: ❑Approved as revised. ODenied. P j O' omments: L UI PUBLI - - E Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BP250U01 CITY OF ATLANTIC BEACH 3/25/11 Application Tracking Step Selection by Revision 15:14:25 Application number . . . : 11 00001809 Address : 631 BEACH AVE RE number : 170113 -0000- - Application type : RESIDENTIAL ALTERATION NCR OLD ACCOUNT NUMBERS . : AB01067 Tenant name, number . . . : Type options, press Enter. 2= Change 4= Delete 5 =View 6 =Fast log 8= Action log maintenance 9 =In /out maint Path - - -- Key Dates - -- - Action Summary - Opt Agency description Rev Step Req In Est Cmpl Last Type By PLANNING & ZONING A 01 N 03/23/11 04/04/11 03/23/11 AP SD PUBLIC UTILITIES A 01 Y 03/22/11 04/04/11 03/22/11 AP LS PUBLIC WORKS A 01 Y 03/24/11 04/04/11 03/24/11 AP LS BUILDING DEPT. 1 01 Y 03/23/11 04/04/11 03/23/11 AP MJ Bottom F3 =Exit F5 =Land inquiry F6 =Add F7= Revisions F8 =Misc info inquiry F9= Corrections report FlO =View 3 F11 =Sort by agency F24 =More keys ks- CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ' ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 t2i.3 Application Number 11- 00001809 Date 4/15/11 Property Address 631 BEACH AVE Application type description RESIDENTIAL ALTERATION Property Zoning TO BE UPDATED Application valuation . . . 125000 Application desc renovations to carriage house Owner Contractor HUGHES SATILLA INC 631 BEACH AVENUE 2742 HERSCHEL STREET ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32205 (904) 389 -3704 Permit MECHANICAL HVAC PERMIT Additional desc . Sub Contractor . ENVIRONMENTAL A/C SERVICES,INC Permit Fee . . . 95.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/12/11 Special Notes and Comments Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247 -5834. Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due PERMIT IS 1N ACCURDANCE PITH ALL CITY 'OF ATEANTIC DRDTQ <<CNCES AND THE FLURIIIA - BUILDING CODES. , CITY OF ATLANTIC BEACH ; ) 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 tt Page 2 Application Number 11- 00001809 Date 4/15/11 Permit Fee Total 95.00 95.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 99.00 99.00 .00 .0 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 z Ph (9 04) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: CO 3 ( �eac f ` AUe PERMIT # //— f rO PROJECT VALUE $ Oek) ' NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity / Tons Per Unit g , - Heat: Unit Quantity BTU's Per Unit 30 Seer Rating (.3, C) Duct Systems: Total CFM /©00 REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALL TIO ARI # 0 6 d Air Conditioning: Unit Quantity 1 Tons Per Unit R Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority o viola the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name is . Pid Phone Number Mechanical Company it UG /'fN me , 6it is ,„ Sercrcaffice Phone a- 79 Fax X79 -,,-,' $ Co. Address: g1' /O C ecs hz 19v 0 / / City e roiv vfri1 e State r'[— Zip ?.?- 1 License Holder (Prin Goctie ' - ,7s 'Y, State Certification/Registration # r ecc.S`74Co Notarized Si: nature of License-Holder / O : �.r" ` SHIRt EYL GRA • , rn and subscribed b ores . y o ` a ; ; ' L 20 / - �' {. �•� c *= MY Cf E M ISSfoN # DD 95776G ,� � _ Plt7 + 1 W= / `IV • � a? EXPI ''�•••• February 1a, 201451 �� , ature of Notary Pub � � , . , � i d tr , t , ' Bon ded 1 rwu Notary public U)d erwriters .9R CERTIFIED TM www.ahridirectory.org certificate of Product Ratings AHRI Certified Reference Number: 1106402 Date: 4/15/2011 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 4TWR3030A1 Indoor Unit Model Number: 4TEE3F31B1 Manufacturer: TRANE Trade /Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 31000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 28600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 15300 Ratings followed by an asterisk ( ") indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION LIMP The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on 0191111 •l. -' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129473549314677500 r irlr ‘ CITY OF ATLANTIC BEACH r Pik F a 800 SEMINOLE ROAD J ��'" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 " .1319 Application Number 11- 00001809 Date 5/11/11 Property Address 631 BEACH AVE Application type description RESIDENTIAL ADDITION Property Zoning TO BE UPDATED Application valuation . . . 125000 Application desc ADDITION AND RENOVATIONS TO CARRIAGE HOUSE Owner Contractor HUGHES SATILLA INC 631 BEACH AVENUE 2742 HERSCHEL STREET ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32205 (904) 389 -3704 Structure Information 000 000 Construction Type TYPE I -A Occupancy Type RESIDENTIAL Flood Zone ZONE X Permit MECHANICAL GAS PIPE PERMIT Additional desc . GAS LINE FOR WATER HEATER Sub Contractor . AA BOTTLED GAS COMPANY INC Permit Fee . . . 65.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/07/11 Special Notes and Comments Avoid damage to underground water /sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247 -5834. Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS PERMIT IS AFPR�v1 ONLY IN ACCORDArI'CW RCILL CITY OF A BEACHCANAUM AND THE FAA BUILDING CODES. , r S' ' CITY OF ATLANTIC BEACH °� 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 r/ t VII3v ' Page 2 Application Number 11- 00001809 Date 5/11/11 Permit Fee Total 65.00 65.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 65.00 65.00 .00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. r r CITY OF ATLANTIC BEACH OA 800 SEMINOLE ROAD, ATLANTIC BEACH, FL 32233 7 1 III I . OFFICE: (904BU)247 ILDI826 EPT@C•FAX NOAB.O.:(904)247 -5845 US - D \ MECHANICAL PERMIT APPLICATION DUVAL COUNTY 1 '• = ADDRESS ., - . I : , .. ; ' , 3f1S THIS A SUB PERMIT'' r k ❑ NO • G C • 1% ' ❑ E PERMIT S # / bcbn / 6 4. NAME: 5. ADDRESS IF DIFFERENT FROM JOB ADDRESS: 6. PHONE: A Li I I 1 �y s,� �g ,',,,,1:4'! 'vim �,, % � . PVMIIECHAIVICANTRAG7tlRMOrd. 4 _ 16, r 1E ak....,.. IN 00 ... 0 #,. 4 f;,,' 7. NAME OF COMPANY: 8. ADDRESS.: f:1- A r C— CO I a.10 n 1 n.. , rn i n S 9. STATE OF FLORIDA LICENSE NO: 10. CELL PHONE: 11. FAX NO.: 12. EMAIL ADDRESS: 13. OFFICE PHONE: 14 _ .75 - 7 -1 ct a4- Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six (6) months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. CONTRACTORS SIGNATURE: (C., .&.LS > 0 S.;Ct SS'ttf NMtORK ..' ' Pik ; :.. , s s 8.... 16 , sIJI.DING; 47 $SERVICE :=" ? V 18; cuRRENteopeadwgo4045 ❑ NEW INSTALLATION ❑ NEW IU- RESIDENTIAL ❑ '06 FLORIDA BUILDING CODE- 0 REPLACEMENT OF EXISTING SYSTEM ❑ EXISTING ❑ COMMERCIAL MECHANICAL 1314(2TERATION / ADDITION TO EXIST SYSTEM ❑ REPAIR ❑ OTHER r,. , mM'',49,..• r 4MECHANICAL EQUIPMENT/TO BE INSTALLED :I 4 Aw ;41ft • K' 19. HEAT: ❑ SPACE ❑ RECESSED ❑ CENTRAL ❑ FLOOR BURNERS: 20. AIR CONDITIONING: ❑ ROOM ❑ CENTRAL 21. DUCT SYSTEM: MATERIAL: THICKNESS: MAX CAPACITY: cfm 22. REFRIGERATION: MAX CAPACITY: cfm 23. COOLING TOWER: CAPACITY: gpm 24. FIRE SPRINKLER: NUMBER OF HEADS: 25. LIFT SYSTEM: ELEVATOR: MANLIFT: ESCALATOR: AUTOLIFT: 26. COMMERCIAL HOOD NUMBER: 27. FIREPLACE: PREFABRICATED: MASONRY: 28. IRRIGATION: ❑ PUMP ❑ WELL ❑ PIPING 29. GAS PIPING: # OF OUTLETS: ❑ GAS AHU: I1147(S WATER HEATER: 30. OTHER - SPECIFY: SOLAR HEATING, BOILERS, UNFIRED PRESSURE VESSEL, HEAT EXCHANGER OR COIL IN DUCTS ETC. VALUE FOR OTHER ITEMS: 9;, + 4' ; , ,5. f a c .4u • 3i r+,QOUNG EQUIPf tEJ T: " �',.�, It *�"�� 4 4-�r ;.. , ,. 04 ',' ,., . AIR COND1T1ON)NG RFRfGERAT1QM EQUIPMEN S RS ETf / / 4 r ." 9 < $ NUMBER APPROVING OF UNITS DESCRIPTION MODEL# MANUFACTURER TONS AGENCY , 3,HI:A1�+' E+ GIIPME T:''.. . • � a -. .. .x: :.. , i ''''' W . ES: BOi `ERS'`IREI ' £ .,.� ems; J ACESAfiFvWANbL1:R�ET.� , . �,•_ _ ' _ NUMBER APPROVING OF UNITS DESCRIPTION MODEL # MANUFACTURER BTU AGENCY '7 i n <$ : $3, TANKS' 1 $ <. tY- 0 1 1 APPROVING NUMBER GALLONS CONTAINED MANUFACTURER SERIAL# AGENCY BLDG04 Permit Applicaton Mach: REVISED: 12/18/2008 F T tiE S z, State of Florida Department of Agriculture and Consumer Services 4. —v ..o Division of Standards ` t/�`'' Certificate No 14813 � , � {� Bureau of Liquefied Petroleum Gas Inspection Exam Date: May 18, 2001 {47 •- E xpiration Date: J ul y Tallahassee, Florida (850) 921 -8001 Issue Date: July 11, 2010 ° °r,,, r y 10, 2013 Exam: 0601 MASTER QUALIFIER CERTIFICATE This Certificate is issued under authority of Section 527.02, Florida Statutes, to: EDDIE GENE THIGPEN Valid For License Number: 01320 A A BOTTLED GAS COMPANY, INC. 12601 N MAIN ST JACKSONVILLE, FL 32218 -2699 H RLES H. BRONS COMMISSIONER OF AGRICULTURE `d - State of Florida m , A Department of Agriculture and Consumer Services " "` Division of Standards '<s•` a ? License Number: 01320 <ro ry a (850) 921 -8001 Bureau of Liquefied Petroleum Gas Inspection Expiration Date: August 31, 2011 POST LICENSE Date of Issue: September 1, 2010 CONSPICUOUSLY Tallahassee, Florida License Fee: $425.00 Type and Liquefied Petroleum Gas License lass: 0601 CATEGORY I LP GAS DEALER FOR ONE LOCATION ONLY ANY CHANGE OF OWNERSHIP OR O SALE OF THIS BUSINESS RENDERS THIS LICENSE INVALID This license is issued under authority of Section 527.02, Florida Statutes, to: A A BOTTLED GAS COMPANY, INC. /1/31g07"41#7 , 12601 N MAIN ST JACKSONVILLE, FL 32218-2699 C H RLES H. BRONS COMMISSIONER OF AGRICULTURE •