Loading...
Permit Mech 800 Seminole Rd 2011 i , r' ✓ ` { � s ; CITY OF ATLANTIC B ti 4"..) BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 '"�` INSPECTION PHONE LINE 247 -5826 Application Number Property Address 800 00001 OL Date 4/11/11 E RD Application type description MECHANICAL HVAC ONLY Property Zoning RES SF DISTRICT Application valuation . . . 0 Application desc CHANGE OUT 5 TON SYSTEM Owner Contractor CITY OF ATLANTIC BEACH WEATHER ENGINEERS INC. 800 SEMINOLE RD 1000 EDISON AVENUE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32204 (904) 356 -3963 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 5 TON SYSTEM Permit Fee . . . 115.00 Plan Check Fee Issue Date .00 Valuation . . . . 0 Expiration Date 10/08/11 Other Fees STATE MECH DCA SURCHARGE STATE MECH DBPR SURCHARGE 2.00 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 115.00 115.00 Plan Check Total . 00 . .00 .00 . .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 119.00 119.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: C9 0 0 5-e r- i N 4 1 R d /+1 B h / Fl RI-35 PERMIT # /- / 9.°7 PROJECT VALUE $ 7 3 a S o NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity 5 BTU's Per Unit i 0 o00 Seer Rating 1 Duct Systems: Total CFM a 60 REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM / REQUIRED FIRE PREVENTION 7 Fire Sprinkler System Quantity / (Requires 3 sets of lans P ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: - Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name (2 -- % •" \( rJ -C t) e, yo + + C_ {3 C k _ Phone Number a LI 1 - 5 8 13 Mechanical Company LU-e.a 11 - r E N ; N .o„e. c S l T N Q. Office Phone S A fi t-- Fax N j A Co. Address: 10 0 0 € d i se lq V 3 00c f 1 3 LZ Q Z- City 3c, c, KS o N V ; \ \ e State F 1 Zip 3a. Q Z- License Holder (Print): Tc, , , , F; NI State Certification/Registration # Notarized Signature of License Holder ,Q ------ - Sworn an subscribed be me this , r ill day of 1 \. 20 i 1 yYa < � a , is tl aLE L _ Jvi l-LIPS Si r U, � . -. !; r iD745624 Signature of Notary Public gat e_ i _ le . 0 4 ! J rat �,,�■. �i � n This combination qualifies for a Federal Energy -- 0 E RTI FI E DTM Efficiency Tax Credit when placed in service www.ahridirectory,org between Feb 17, 2009 and Dec 31, 2011. C ertificate of Product Ratings AHRI Certified Reference Number: 3495355 Date: 4/11/2011 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 226ANA060 -A Indoor Unit Model Number: FV4CNB006 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade /Brand name: LEGACY 16 PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 56500 EER Rating (Cooling): 12.60 SEER Rating (Cooling): 16.00 Heating Capacity(Btuh) @ 47 F: 59000 Region IV HSPF Rating (Heating): 9.50 Heating Capacity(Btuh) @ 17 F: 36600 *Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION A URN The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on AM... •' which the certificate was issued, which is listed above, and the Certificate No., which is listed below. and Refrigeration Institute ©011 Air- Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129470051371998756