Loading...
Permit Irrigation 1224 Ocean 2011 _ jr . � ,,, ., 0 , CITY OF ATLANTIC BEACH '' ' ,,:..4 ,; * - 800 SEMINOLE ROAD , ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5826 �Jjfi Application Number 11- 00001908 Date 4/12/11 Property Address 1224 OCEAN BLVD Application type description PLUMBING ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc IRRIGATION SYSTEM Owner Contractor LADA LAWN IRRIGATION SERVICES LLC 1224 OCEAN BLVD. 2604 SEBAGO AV ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 Permit PLUMBING PERMIT Additional desc . Permit Fee . . . 62.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/09/11 Other Fees STATE PLBG DCA SURCHARGE 2.00 STATE PLBG DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 62.00 62.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 66.00 66.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) Aa "z. 800 Seminole Road Atlantic Beach, Florida 32233 -5445 Phone (904) 247 -5826 Fax (904) 247 -5845 ` E-mail: buildin de t coab.us Date routed. f g p @ City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: / 5 ' )11 /3 Department review required Yes No BuiIdin AppIicant:���l _ Tannin & Zoning tree Admini�or Project: Public Works Public Utilities Public Safety Fire Services e =. `$ �. x u ""." ' .. ,f"=" 5 .;S`3"f. ^au? z y s . aisa ee p 9 Reie vws y5 I De txSi nature ... :, �� r;y; a ,. a... ..n.uW.,..w ,.wec ....�:.�" Wa...+.x.,..u._ w, .a,.o. ttir � x . -r .0 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: XApproved. DDenied. (Circle one.) Comments: BUILDING 'LANNING & ZONI Reviewed by: Date: �!'/� REE ADMIN. Second Review: (Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ['Denied. Comments: Reviewed by: Date: Revised 05/14/09 PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / es.\ Vl 1 PERMIT # NEW OR REPLACEMENT INSTALLATION: Project Value $ TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank & Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE -PIPE: TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank & Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement cAlack Flow Preventer ❑ Grease Interceptor (Trap) gallons (Requires 3 sets of plans) P Sprinkler System- Number of Heads ay ** ** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection. ** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name • 3 €r Y- oce( k Ct Phone Number Plumbing Company Lchto IN rrl a-i-i 3(rl2I e4 S Office Phone `s /50Y/ Fax / Co. Address: [00y Phcty ) I IJG • City Al- Iavt4- rc WA State 'pi • Zip 3)0,932 License Holder (Print): R0A5‘E State Certification/Registration # - +)9 /STS Notarized ~ S 'ogre o/6 1 W ld *• ,.� ;,,= MY COMMISSION # DD 634126 a � EXPIRES: May 21, 2011, and subscribed befor- m- this // • ay of i .�/L� 20 / 7 -: p tc Bonded Thru Notary ublic Und ry Signature of Notary Publ' k OraWl /'I 4130 770 63 9/0 WI A P 3 HOWING BOUNDARY SURVEY ®F LOT 1 BLOCK 49 ACCORDING TO THE PLAT OF AS RECORDED IN PLAT BOOK 11 ® (S) LAY 11 OF' THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: JENNIFER L. LADA, GIBRALTAR TITLE SERVICES, OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY, AND EVERBANK. OCEAN BOULEVARD 50' R/W 3/4" 50.18' (M) UNDER 50.00' (R) WALK b � :•1 - 3/4" O * N c0 N V' °'.." : N9 4' N CONCRETE N WAUC o ° o 'a v iie ,/� 0.9' 9 PLA NTER � `� ~ ry ° /��+`() s I� PLANTER A � S y V • 1 7 1 i M _2 \ ___ ; � 4' 1ST FLOOR CONCRETE PORCH , : yini ii^ ° BRICK 2ND FLOOR BALCONY 5' WALK 6 . 5 26.2' _ 17.5' • ' • 1.2' • PON, CD Ul v Ss v' v �j U U 1/ O O T. - - - -- ° 1�1 •° bid (� m m N W V 1 & 2 STORY CON ■U 0 0 ; , FRAME ,, Q ' III_ BRIC OC E N tr —' —' 0 RESIDENCE �- 4 w A LK ^ 3 . �.. NO. 1224 O , � w o , WELL c\1 AC PADS 5 / 1. c- (V 1— ,_. 6. T-- 26.3' 17`x' . COVERED CONCRETE 17..3 J ' • 0.1' 5.4' 27.7' ' CONC . ' WALK 9 STUCCO • P ' M & FRAME '? ' • • • N GARAGE "' ONCRETE. C a N : >. . DRIVE . rit, 1w 27.6' 5.5' , 1 I' 1 17.1' w c CONCRETE v� = = 0.5' TO 0.9' CONCRETE WALL METAL WALK v 6 SHED 6 d Y c � N R ON SKIDS III ,Q.O 0 CONC S. 0.5' °§ STOOP 2.2' J SUBDIVISION BOUNDARY �a 9 1/2' 50.00 (R) 2.5 7 J2" , o a LB 3672 LB 3672 , 50.26' (M) LOT 2 BLOCK 4 , ATLANTIC BEACH PARKWAY, UNIT NO. 2 PLAT BOOK 15, PAGE 83 FLOOD ZONE "X" m AREAS DETERMINED TO BE OUTSIDE THE 0.25 ANNUAL CHANCE FLOOD PLAIN / FLOOD ZONE "X (SHADED)•' o AREAS OF 0.25 ANNUAL CHANCE FLOOD; AREAS OF IX ANNUAL CHANCE WTH AVERAGE DEPTHS OF LESS THAN 1 FOOT OR WTH DRAINAGE AREAS LESS THAN 1 SQUARE MILE: AND AREAS PROTECTED BY LEVEES FROM 1X ANNUAL CHANCE FLOOD. ,1 E Y p GENERAL NOTES: J R , R ■S 1. ANGLES ARE SHOWN FOR THIS SURVEY. ��� _ _ 2 . STRUCTURE NO. 1224 SHOWN HEREON LIES WITHIN FLOOD ZONE . _ X Ac . r1 ! -=\1:1 l Florida Friendly Landscapes s IRRIGATION COMPLIANCE CHECKLIST j yr DATE LI" // A. PROVIDE PROJECT INFORMATION: SIDENTIAL, ADDRESS /9 L i O e eINN Q) NEW INSTALLATION RESIDENTIAL, CONTRACTOR h--Awn Irr9a- l-x)V' Sj I& ?.S _1-L UPGRADE /REPLACE ~� NON- RESIDENTIAL, OFFICE a L i I — .S U ! CELL 3 ? ,3 /.70 FAX aq `S05 - 7 n NEW INSTALLATION t NON - RESIDENTIAL, EMAIL r:k�v4- 0162_ be//sou74, / j / 4 UPGRADE /REPLACE B. CALCULATE MAXIMUM HIGH VOLUME IRRIGATION: HYDROZONE shall mean an irrigation watering zone _ r _ SQ FT in which plant materials with similar water needs are TOTAL LOT AREA C , �S grouped together. TOTAL IMPERVIOUS SURFACE AREA - � SQ FT HIGH VOLUME IRRIGATION shall mean an irrigation system that does not limit the delivery of water directly to the root zone and which has a minimum SQ FT flow rate, per emitter, of thirty (30) gallons per hour TOTAL PERVIOUS AREA /LANDSCAPE 3 ��y (gph) or one -half (.5) gallons per minute (gpm) or greater. (PER SECTION 24 181(b)(4)iil x 0.60 IRRIGATION ZONE shall mean the grouping together / •� SQ FT of any type of water emitter and irrigation equipment MAX HIGH VOLUME IRRIGATION � c�3 � p operated simultaneously by the control of a timer and a single valve. C. PREPARE & ATTACH A HYDROZONE PLAN: ON A COPY OF THE SITE PLAN OR SURVEY (RESIDENTIAL APPLICANTS) OR A LANDSCAPE PLAN (NON- RESIDENTIAL APPLICANTS), INDICATE THE LOCATION OF THE FOLLOWING AND FILL IN APPROXIMATE COVERAGES BELOW. Id HIGH WATER USE HYDROZONE(S) [ALL APPLICANTS] ( R(,) SQ FT a e 5- %TLA High Water Use Hydrozones contain plants that require supplemental watering on a regular basis throughout the year. These areas include turf and lawn grasses and are typically characterized by high visibility focal points of landscaping design where High Volume Irrigation is used. High Water Use Zones shall be placed on a separate irrigation zone. MODERATE WATER USE HYDROZONE(S) [NON - RESIDENTIAL ONLY SQ FT % TLA Moderate Water Use Hydrozones contain plants that, once established, require irrigation every two to three weeks in absence of rainfall or when they show visible stress such as wilted foliage or pale color. These are typically perennials, seasonal plants and flower beds. F LOW WATER USE HYDROZONE(S) [NON - RESIDENTIAL ONLY] SQ FT % TLA Low Water Use Hydrozones contain plants that rarely require supplemental watering and that are drought tolerant during extreme dly' periods, such as native shrubs and vegetation, established trees and ground covers, and wooded areas. Rfi\�� T/MOrSTURESENSOR(S) [ALL APPLICANTS] At least one (1) moisture sensor shall be located in each Irrigation Zone. MITTERS ALL APPLICANTS] Emitters shall be sized and spaced to avoid excessive overspray on to impervious surfaces. City ofAtlantic Beach • 800 Seminole Road • Atlantic Beach, Florida 32233 (P) 904.247.5800 • (F) 904.247.5845 • www.coab.us FFL- ICCv12.07.10