Permit Mech 725 Redfin 2011 ci _ CITY OF ATLANTIC BEACH '' 800 SEMINOLE ROAD U ' ` ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 ,. %.)1119f Application Number 11- 00002011 Date 4/28/11 Property Address 725 REDFIN DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 ahu Owner Contractor WEEKS A COMFORTABLE ENVIRONMENT, INC 725 REDFIN DRIVE 250 WINTER SPRINGS WAY ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 221 -5386 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 75.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/25/11 Fee summary Charged Paid Credited Due Permit Fee Total 75.00 75.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 75.00 75.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 725 K e- of 1 I 1J Oki.. PERMIT # PROJECT VALUE $ LI 06 ' 6° ARI# 31 7- c ni -1 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 2 S 3 Heat: Unit Quantity BTU's Per Unit Seer Rating 13. Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name gy A N) V.) -e-Q \< -S Phone Number 7 ' Z,_ 9R., '1 Mechanical Company A C a M F o'- 4c) 4, ( V r'1r a r- nN t 2^'C . Office Phone 27./1 - S3 a Fax 7,7/ I - SSA a Co. Address: 2 S� \; id-} e i .gyp f; b y -s' W A 7 City J AI- State L- Zip 3 Z Z Z S License Holder (Print): 4 le, u g P. D ° c in) . S, . State Certification/Registration # C ✓ 1 C6 V) 0 d Notarized Signature of License Holder t /! * r -- i p 0-4- 7 ,rf r �. '__ Commission # DD 946778 •; : MARY ANNE DUPONT S Horn and subscribed before me this a g day of P r- 20 t �` ��f�f W Expires January 19, 2014 S 'gnature of Notary Public i i 704. £Z j't4 L A it. Raided Thru Troy Fain Insurance 800385 -7019 Apr 28 2011 3:12PM BAKER DIST #314 904- 998 - 9169 p•1 Baker GRANDAJREi DlstrlbuUng Company Heating 6' Cooling Products 13 SEER 410A HEAT PUMP _ Width Depth Height Filter Line Size 1.5 TON WCH3184GKA 23 1l8 23 118 28 7/16 1 3/8" 13 SEER WAHM184A 22 118 14 5/16 4211/16 13 x 21 1/2 ARI #( 3140977 EHK05AKN 131SEER 10.81EER 7.71HSPF 3/4" Width Depth Height Filter Line Size 2 TON WCH3244GKA 23 1/8 23 1/8 28 7/16 3/8" 1 it 13 SEER WAHM244A 22 1/8 17 7/8 4711/16 16 3/8 X 21 1/2 ARI #I 3129868 EHKO7AKN 13ISEER 10.6JEER 7.71 HSPF 3/4" Width Depth Height _ Filter Line Size 2.5 TON WCH3304GKA 23 1/8 23 1/8 35 3/16 16 3/8 X 21 112 3/8" 13 SEER WAHM304A 22 118 17 7/8 49 5/8 ARI #1 3129871 EHKO7AKN , 13ISEER 10.5IEER 7.71 HSPF 3/4" Width Depth Height Filter Line Size 3 TON WCH3364GKA 31 3116 31 3/18 28 7/16 19 7/8 X 21 1/2 3/8" 13 SEER WAHM364A 22 118 21 1/8 53 7/16 ARI #I 3129874 EHK1OAKN _ 13IsEER 10.8 JEER 7.7 f HSPF 7/8" Width Depth Height Filter Line Size 3.5 TON WCH3424GKA 31 3/16 31 3/16 3113/16 197/8 1/2 3 /8" 13 SEER WAHM424A 22 1/8 21 1/8 49 5/8 ARI #I 3129877 EHK1OAKN 131 SEER _ 10.6 IEER 7.71 HSPF 718" Width Depth Height Filter Line Size it 4 TON WCH3484GKA 31 3/16 31 3/16 38 5/8 19 7/8 X 21 1/2 3/3" 13 SEER WAHM484A 22 1/8 21 1/8 63 7/16 ARI #I 3129880 EHK1OAKN 131 SEER 10.6 IEER 7.81 HSPF 1 1/8" Width Depth Height _ Filter Line Size 5 TON WCH3604GKA 31 3/16 31 3/16 31 13/18 23 5/16 X 21 112 3/8" 13 SEER WAHM604A 22 1/8 24 11/16 59 3/16 , ARI #I 3129883 EHK15AKI3 131 SEER , 11 j EER 7.8_ HSPF _ 1 1,8" Heater Kits with Breaker - EHKO5AKB EHKO7AKB f 1 EHKIOAKB 1 Year Unit Replacement Limited Warranty 10 Year Compressor Limited Warranty 5 Year Parts - (Additional 5 Year Parts If Properly Registered) Rev 09/21/10 Prices subject to change without notice. GAI CPT 1