Permit Comm Int Build out 363 Atlantic #1 2011 S r� 4 ' r f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 4 '' ' �} ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002019 Date 5/19/11 Property Address 363 ATLANTIC BLVD UNIT 01 Application type description COMMERCIAL INTERIOR BUILD -OUT Property Zoning TO BE UPDATED Application valuation . . . 250000 Application desc INTERIOR REMODEL Owner Contractor SHOPPES OF NORSHORE LLC URBAN PARTNERS CONSTRUCTION P.O. BOX 330108 4320 PABLO PROF CT STE 103 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32224 (904) 219 -7579 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type MERCANTILE Permit ELECTRICAL PERMIT Additional desc . REPAIR RELOCATE AND REMODEL Sub Contractor . LIMBAUGH ELECTRICAL CONTRAC Permit Fee . . . 90.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/15/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS FLORIDA FIRE PREVENTION CODE NATIONAL ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE ELEC DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 90.00 90.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 94.00 94.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph (904))247 - 5822 Fax (904) 247 -5845 c 4 7 — 5S JOB ADDRESS: • - a3 P - t,(' ni-1'c-7B( vdl • - -= PERMIT # 1/ Z'/ JEA INFORMATION REQUIRED ON ALL PERMITS 60) , ,AMPS ZYDVOLTS . � j PHASE ll VALUE OF WORK $ �j`/ 5 0v NEW SERVICE ❑ Overhead ❑ Underground D Underground up Pole ❑Residential (Main) Service 00 - 100 amps ❑ 101 150amps ❑ 151 200amps ❑ amps # of Meters ❑ Commercial (Main) Service 00 -100 amps 0101- 150amps ❑ 151- 200amps ❑ amps OCT Service amps Conductor Type Size ❑Multi Family (Main) Service 00 - 100 amps ❑ 101 150amps ❑ 151 200amps ❑ amps # of Unit Meters OTemporary Pole ❑ amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.) ❑ 100 amps ❑ 150amps 0200amps ❑ amps OCT Service amps ADDITIONS, REMODEL& REPAIRS, BUILD - OUTS, ACCESSORY STRUCTURES, ETC. Outlets /Switches: / $ 0- 30amps 31- 100amps 101- 200amps Appliances: 0- 30amps 31- 100amps 101- 200amps A/C Circuits: 0- 60amps 61- 100amps Heat Circuits: # circuits @ kw�� Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS :Swimming Pool ❑ Sign ❑Smoke Detectors _ Qty OTransformers KVA ❑Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts/amps VALUE OF WORK $ REPAIRS/MISCELLANEOUS //v34G% A&4 S G1,- /y. :Replace Burnt/Damaged Meter Can ❑Safety Inspection OPanel 6. Change ❑ OH to UG // if6ther: fibit - 4u/f& ba- Q4e'4� G�"lZ/`�� /2e (/`� 4ky 1 1 4 �/'l. /,L»v �5 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances goveming this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. , Property Owners Name t S L /t9 le/ el1 /4k' Phone Number 9 3r- 749 --1 7F` Electrical Company) irribli ill F.ler-A 1 crlitric_A- i (13TIT ,Office Phone at (--qa5 I Fax Co. Address: 4-2 Las+ /��,�l! ( ci e City At tiff iC =t State Ft • Zip 3223 License Holder (Print): ,, r— L ' k tic State Certification/Re ist v g 1 Notarized Signature of � z g e f License Holder 01) )c �� Sworn and sue .cribed •ef®• : this I"I" may of 1 _ 201 t e m Signature of Notary Public _ . / . 1 J _ �� ,t f ' ,. ji � City of Atlantic Beach Building Department Certificate of Completion This Certificate issued pursuant to the requirements of Section 110.2 of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: Date: August 24, 2011 Contractor: Urban Partners Address: 363 Atlantic Boulevard Unit 01 (POE' S) Occupancy Classification: Restaurant Maximum Occupancy: 175 Seats Permit Number: 11-2387 and 11 -2019 ) it 4 Michael Griffin, BO, CFM Building Official 0 t 4111L i CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD �.� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002019 Date 5/18/11 Property Address 363 ATLANTIC BLVD UNIT 01 Application type description COMMERCIAL INTERIOR BUILD -OUT Property Zoning TO BE UPDATED Application valuation . . . 250000 Application desc INTERIOR REMODEL Owner Contractor URBAN PARTNERS CONSTRUCTION 4320 PABLO PROF CT STE 103 JACKSONVILLE FL 32224 (904) 219 -7579 Structure Information 000 000 Construction Type . . . . . TYPE 5 -B Occupancy Type MERCANTILE Permit COMMERCIAL ALTERATION /OTHER Additional desc . Permit Fee . . . 930.00 Plan Check Fee . . 465.00 Issue Date . . . Valuation . . . . 250000 Expiration Date . 11/14/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS FLORIDA FIRE PREVENTION CODE NATIONAL ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Fee summary Charged Paid Credited Due Permit Fee Total 930.00 930.00 .00 .00 Plan Check Total 465.00 465.00 .00 .00 Grand Total 1395.00 1395.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. G �S0Al x t x P F1FC ;'%i4r,O Ostiii ,Fire ' rev9 - tf : n "NJ m 1 E '� SHIM Fs cuf aCQ i EXCEP':ON FIRE PREVENTION DIVISION OFFICE OF PLAN REVIEW May 9, 2011 C f t TO: Atlantic Beach Building Department / /j FROM: Captain Bob Ratliff SUBJECT: Plan Review for Poe's Tavern 363 Atlantic Blvd. The following discrepancies are noted on the plans as submitted: 1. Comply with FAC 69A- 60.0081 Notice Required for Structures With Light -frame Truss -type Construction. " 2. NFPA 1- 11.1.7.1* Means shall be provided for the fire department to disconnect the electrical service to a building, structure, or facility when the electrical installation is covered under the scope of NFPA 70. /, ,yegvr- y- •p 11.1.7.2 The disconnecting means shall be maintained accessible to the fire . department. , 4 ., , r zr z &e`rtpN r fT P'dc" 11.1.7.3 Identification of Disconnecting Means.+, ��c _ 5,4" 11.1.7.3.1 Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose is evident. /.r" y 11.1.7.3.2 The marking shall be of sufficient durability to withstand the environment involved. � ' 1 /7149 3. NFPA 101 - 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapter 11 through Chapter 42 ... Provide Emergency Lighting in required areas. :.:= .'ey G.(977,77N �`,u'✓'V 4. NFPA 101 - 12.2.2.2.3 Any door in a required means of egress from an area having an occupant load of 100 or more persons shall be permitted to be provided with a latch or lock only if the latch or lock is panic hardware or fire exit hardware complying with 7.2.1.7. Verify Panic Hardware. , re"G -2' ,yrir ✓N a Facia Begins. 214 N. Hogan Street 1 Jacksonville, FL 32202 -4128 I Phone: 904 - 255 -8320 I Fax: 904 -255 -8559 I bratliff@coj.net 5. Answer all comments in written summary with revised / clouded plans. y arAsvi‘ Ada . 214 N. Hogan Street 1 Jacksonville, FL 32202 -4128 1 Phone: 904- 255 -8320 1 Fax: 904 - 255 -8559 1 bratliff @coj.net _ / 106 7 ATT-ifiv / i 1 ■ 1 i i ! -,.. -- 1 ;, ', ,, (&, , .,...) 1 k ' i i i f ! t t I ■______LI I I I I I I ., ii ,, :t.k,t - Le t-d, ` c c_.,- - ' :, .._, • ,.._ . I I i i r j i . . i ! 7 ----- ! ! ,!........ -. ----._. .1-% '- - -,, ■ . ■ '=. --'' {--, I .e '.-,.. / ,• ' r ;-•; . - - / ..,144.=. __ 1.,,__ FI ------, t i L4: r .'. (15''. ' t i ........., .., ,.. . ._. : ,, ,, 1 - i i 1 i i ' „ 7 , , , ---?, , , a, • ; i ! i r-------, . , 1 r----- ,....j....; 1 ; t■'.2.--1 L ,ili 1 7 i 1 ' ::: !.. r• -!-!' . !. .. - t ; L (31 A to Z Contracting Inc : 46 1 : .:._ ...,_ . , s,:. er : ..i. , AM411.ffili ‘ . 1 . i ..: FILE i x " . :.Brett Thomas Office: 390-0907 President Fax: 783-1280 C: 219 EMAIL 1-ea* EiVt Masteripcgeonlcast.net .,„ „...-, -, „,:,,,,-;-., ,-:••,:' -.... -„,,,,,..: . it .• ...„..,,,„........„.. -,,, ,.., ..: ct , t 1 . . . hdo3 311,1 . I , . i t.:. _ ..... 1716ai li' c2 ?eetthwi c &cifitraethw, ,fne, 1 6t' t 8 Street ,lt /ar�7ic Beach. Florida 32233 Phone (904) 241 9051 Fax (904) 249 -07)3 alexlimbaugh@bellsouth.net April 25 2011 Urban Partners Construction CIO Mike Bressler 4230 Pablo Professional Ct., Ste 103 Jacksonville, Fl. 32224 904- 270 -2225 office 904- 270 -2245 Fax 904- 614 -2085 mobile Job Information : Poe's Tavern 363 Atlantic Blvd. Atl. Bch., Fl. 32233 Mike, Here is the information I believe you will need for the City of Atlantic Beach building department for your BP# to be issued. If I can be of any more assistance or they need more information please call me at 904- 219 -5044. Loads being added in the bar are replacing equipment that was removed when the bar area was relocated. 1 - 120 volt 15.4 amps glass washer 1 - 115 volt 9.1 amp Bar Back Cooler 2 - 115 volt 12.5 amps each Draught Beer Towers 1 - 115 volt 15 amp glass chiller 1 - 115 volt 6.3 amp bottle cooler. The existing lighting outlets are being removed and replaced as shown on Drawing # A900 dated 3/30/11. They are similar in number to the those being removed. The additional loads are 1 - 5 ton 3 phase 240 volt AC unit. 2 - walk in coolers - no data available as of 4/25/11. The existing service is 3 phase 240 volt 600 amps and is adequate for the loads both existing and those being added. Thank you, Alex S. Limbaugh State Certified Electrical Contractor EC13002296 1? arr J`4 /-)69e 15 - :56 /f� f °' ` " ' /, / ' ''b. '. . 4 44 5 l , "5 ' r# , 4-6e/I U O &I ccs s t"tskcf 6) 6q" /2gv /5( 2,0 ,0 4 ? ( r'' C / /6v 49,/4 f 0 9,b, ikt- t3 c I 115 /Z5 E] c)r ,S. GL, It ,- F- / /s /54 e .. e, e t, w +Gtl'i,k c <„ k ' a : Li (_ , , i �- 0 n Item # -- --- Quantity -- _._ --- C.S.l, Section 11 400 i `H O B A R T/ LXiG r = 701 S Ridge Avenue, Troy, OH 45374 G LASS WAS H E R 0 1- 888- 4HOSART • www.hobartcorp.com __.._ __._____— a STANDARD FEATURES STANDARD VOLTAGES XI • 30 racks per hour ❑ 120/60/1 (LXiGC model only) 4%,„„,. • .74 gallons of water per rack ❑ 120/208- 240(3W)/60/1 • Hot water or chemical sanitation units available • Low chemical alert indicator VOLTAGE OPTIONS AT EXTRA COST • Sense -A- Temp'" booster heater capable of ❑ 208- 240(2W)/60/1 70° rise, provided on LXiGH models • Delime notification with cycle ACCESSORIES • Chemical pump "auto- prime" ❑ Power cord kits • Service diagnostics ❑ Pressure regulator valve • Fresh water rinse ❑ Caster assembly kit • 16 gauge stainless steel tank ❑ Trim kit, top cover • Microcomputer, top mounted controls with ❑ Rolled top, dish rack holder digital cycle/temperature display III Revolving upper and lower anti - clogging ❑ DWT2 drain water tempering kit wash arms Specifications, Details and Dimensions on Back. i • Revolving upper and lower rinse arms • Removable stainless steel scrap screen • Corrosion resistant pump • Automatic pumped drain • 12" door opening • Automatic fill '1' 1 • Labyrinth -type door seal a1' • Electric tank heat ' ,, °,; - ,� ; • Two dishracks - one peg and one combination - $ r, I type • Detergent and rinse aid pumps NOHART' CD i C CO US 0 F�EF(I S?Af, _ s t CD LISTED 4'06404 0 , m XI F -8367 - LXiG Glasswasher Page 1 of 2 7 LXiG ‘HOBART/ ' GLASSWASHER 701 S Ridge Avenue, Troy, OH 45374 1- 888- 4HOBART • www.hobartcorp.com WARNING: REQUIRED FLOWING WATER PRESSURE TO THE GLASSWASHER IS 20 t 5 PSIG. IF PRES- 12.7/8" SURES HIGHER THAN 25 PSIG ARE PRESENT, A PRESSURE REGULATING VALVE MUST BE 12" INSTALLED IN THE WATER LINE TO THE GLASSWASHER (BY OTHERS). IMPORTANT: THE SODIUM HYPOCHLORITE (LIQUID BLEACH) CONTAINER SHOULD BE 2" PLACED NO HIGHER THAN 10" ABOVE FLOOR. ( I 1. 5/16" IF BLEACH CONTAINER IS TO BE PLACED IN CABINET ADJACENT TO GLASSWASHER, A ��i� 1/2" DIA. HOLE IS REQUIRED IN THE CABINET TO RUN BLEACH SUPPLY LINE. // �� A .ir� F 0 USE ONLY 6% SODIUM HYPOCHLORITE (LIQUID BLEACH) AS SANITIZING CHEMICAL TO INSURE PROPER OPERATION OF DISHMACHINE. IF 8.496 IS TO BE UTILIZED, CONTACT T J r HOBART SERVICE TO CHANGE THE SANITIZER PUMP SETTINGS. T, O 13- 3/16" D0 NOT PRE -MIX WETTING AGENT AND SODIUM HYPOCHLORITE (LIQUID BLEACH), , A 17.3/16" CERTAIN MATERIALS INCLUDING SILVER PLATE, ALUMINUM AND PEWTER ARE ATTACKED V BY SODIUM HYPOCHLORITE (LIQUID BLEACH). SEE INSTRUCTION MANUAL. v „ 1, AL , / 1, ALL VERTICAL MACHINE DIMENSIONS TAKEN FROM FLOOR MAY BE INCREASED BY 1". 2. USE ONLY MOISTURE RESISTANT MATERIALS ADJACENT TO LXIG SIDES AND TOP, , S ; ♦ CIP 1 3. A VENT HOOD IS NOT RECOMMENDED ABOVE THE LXIG UNDERCOUNTER GLASSWASHER I I SINCE IT DOES NOT PRODUCE EXCESSIVE VAPORS I I' 1 3" PLUMBING NOTES-. J MIN. 1. WATER HAMMER ARRESTOR (MEETING ASSE -1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN COMMON WATER SUPPLY LINE AT SERVICE CONNECTION. 2, RECOMMENDED WATER HARDNESS TO BE 4 -6 GRAINS FOR BEST RESULTS. & 3 MINIMUM WATER CONDUCTIVITY REQUIRED - 30 MICRO- MHOS /CM. IF DRAIN HOSE IS LOOPED ABOVE A SINK, THE LOOP MUST NOT EXCEED 38" AFF. _ _ WARNINQ CONNECTION INFORMATION S 2 �" � ELECTRICAL AND GROUNDING CONNECTIONS ( AFF . ABOVE FINISHED FLOOR) � 4 1 \ MUST COMPLY WITH THE APPLICABLE PORTIONS LEGEND OF THE NATIONAL ELECTRICAL CODE AND /OR E1 ELECTRICAL CONNECTION: 1.3/8" DIA. HOLE FOR' �.� OTHER LOCAL ELECTRICAL CODES. 1" TRADE SIZE CONDUIT; 31 -3/4" AFF. — - PLUMBING CONNECTIONS MUST COMPLY WITH P1 SINGLE FILL AND RINSE CONNECTION: 3/4" FEMALE APPLICABLE CODES. DRAIN AND LINE CONFIGURATIONS AIONS WIT HI WITH MACHINE, 1 0 F WATER MIN, FOR LXIGC, 11 �! N VARY, SOME METHODS ARE SHOWN ON THIS DRAWING. WATER MIN. FOR LXIGH, 1 -1/2" AFF. AMINE 23- 15/16" P2 DRAIN CONNECTION: 3/4" MPT FITTING WITH 6' LONG HOSE SUPPLIED WITH MACHINE; 3-9/18" AFF. S 38- 13/16" 1-1/2" TRADE SIZE E ' - 9" MIN. PIPE MIN. REDUCED �� CONTROLS 26.3/4" --- DOWN TO 3/4" FPT ii - �� DRAWER CONNECTION (BY CUSTOMER) ACCESS 25-5/16" (� 1- 5/16" MIN. 1 ----� 33.3/4 - HOSE 11.11" RECOMMENDED 17" Q MAX. 6 CLEARANCE 4 ' OR LESS • • ` c . •. - *_ % ' II I HEIGHT RINSE -AID 0 P1 J ' AMIIIIIIIIMMI DETERGENT CHEMICAL BOTTLES � Inv RECOMMENDED WATER SERVICE 9/18" MAY BE LOCATED ON / ROUGH -IN 1/2" TRADE SIZE PIPE ..-22- 13/18" EITHER SIDE OF MACHINE �/ CHLORINE _ MIN. W /SHUTOFF VALVE, LINE ¢A ∎ I SANITIZER STRAINER & 3/4" MALE GARDEN - ∎` LXiGC ONLY HOSE FITTING (BY CUSTOMER) t _ -�� MIN SUPPLY MAX 14 - 3/8" ' j'I \ MACHINE TYPE & RATED CKT CONDUCT PROTECTIVE Y SPECIFICATION AMPS AMPACITY DEVICES LX aC (120/60/1) 3 - 7/8" 15 USE 90 "C STRANDED 15.4 20 20 COPPER WIRE ONLY. LXIGC (120/208-240(3W)/60/1") LXIGC (208 - 240/60/1) 13.6 20 20 " THIS SYSTEM REQUIRES THREE POWER WIRES WHICH INCLUDES USE 90 STRANDED A CURRENT CARRYING NEUTRAL, AN ADDITIONAL FOURTH WIRE COPPPPER R WIRE ONLY. MUST BE PROVIDED FOR MACHINE GROUND. LXIGH (1 20/206- 240(3W)/60/1 ") LXIGH (208. 240/80/1) 37,7 50 50 ACCESSORY CORD KITS AVAILABLE FOR ALL MACHINES USE 90 °C STRANDED COPPER WIRE ONLY. ELECTRICAL OPTIONS BELOW ARE NON STANDARD VOLTAGES AVAILABLE SHIPPING WEIGHTS (LBS) LXIGC LXIGH MODELS: AT EXTRA COST. CONSULT FACTORY FOR PRICING AND LEAD TIME. NET WEIGHT OF MACHINE 194 Ibs. 214 Ibs. LXIGC, LXIGH LXIGH 208- 240/60/3 29.5 35 35 DOMESTIC SHIPPING WEIGHT 239 Ibs. 259 Ibs. 892881 480/60/3 14.8 20 20 220- 240/50/1 38.1 50 50 380- 400/60/3 17,1 25 25 As continued product Improvement Is a policy of Hobart, specifications are subject to change without notice. Page 2 of 2 F -8367 — LXIG Glasswasher F -8387 (REV. 10/07) LITHO IN U.S.A. (H -01) 0 P.i..mo. im 0 AIA # TRUE FOOD SERVICE Project Name: v EQUIPMENT, INC. Location: St. Charles Industrial Center • P.O. Box 970.O'Fallon, Missouri 63366 515 # (636)240 -2400 • FAX (636)272 -2408 • (800)325 -6152 • www.truemfg.com Item #: Qty: Parts Dept. (800)424 -TRUE • Parts Dept. FAX# (636)272 -9471 Model #: Model: Back Bar Cooler: TBB -3G-S Glass Door, Stainless Steel Exterior TBB -3G -S 1 True's refrigerated back bar coolers are designed with enduring quality and value. Our commitment to using the highest quality materials and oversized refrigeration assures colder ,LLB __ _--- _ product temperatures and years s " ,. ``. of trouble free service. - ett�v, ' " °� 1 Oversized, factory balanced, 1 ) ° • i f(+ refrigeration system holds 33 °F r„ ° ' ' . to 38 °F (.5 °C to 3.3 °C). 1--.- - Ut 1 ) ate _ . I ► Exterior - stainless steel front, countertop. Matching 1` ' t, ( l t : sides and counterto aluminum back. `� T ' ! x'' / Interior - 300 series stainless steel ii e ` t , :1 floor with 1 /2" (13 mm) reinforced �� lip and heavy gauge galvanized "I ", i4 , , steel walls. NSF approved for pre • ' packaged and bottled product. „.;;: f 1 Positive seal doors. thermal . ,{ �' 4 ► Low -E ", double � n u , � . � glass door assemblies with extruded aluminum frames. i � The latest in energy efficient technology. 1 Patented integrated door light (IDL) system for brighter, shadow free illumination. ► Entire cabinet structure foamed - ) in -place using high density, CFC 5 free, polyurethane insulation. 0 , .. ,,f ti , 0 0 m i. 1YUS_ i •, S; v , -; , , r0 be bu it t C,, 3 ,,, ,, , , ,. ROUGH-1N DATA Specifications subject to change without notice. Chart dimensions rounded up to the nearest 1 /8" (nt ■ << , ! - ( 1 Cabinet Dimensions Cord ! Crated Ca aci (inches) Length Weight 12 oz. 1/2 —,_ (rnm) NEMA (total ft.) (lbs.) Model_ __ Doors Cans Barrels Shelves L Dt H HP Volta .e Am•s Config. (total m ,,�r, TBB -3G -S 2 161 3 4 69 27 37 1 /2 115/60/1 9.1 5 -15P 7 405 6 acks 1 7Y) 699 970 1/z t 50 2/X015011 5 -'1 � I tr?r t Depth does not include 1 (:35 mm) for door handles. A Plug typ , fie I , 40 au APPROVALS: AVAILABLE A7: 11 ITt461. "" O NSE 4/06 Printed in U.S.A. d I Model. Back Bar Cooler: "ma tivitahreimir TBB -3G -S Glass Door, Stainless Steel Exterior STANDARD FEATURES DESIGN • Insulation - entire cabinet structure is MODEL FEATURES • True's refrigerated back bar coolers foamed -in -place using high density, • Evaporator is epoxy coated to are designed with enduring quality CFC free, polyurethane insulation. eliminate the potential of corrosion. and value. Our commitment to using • Welded, heavy duty galvanized frame • Listed under NSF -7 for the storage the highest quality materials and dipped in rust inhibiting enamel paint and/or display of packaged or bottled oversized refrigeration assures colder for corrosion protection inside and product. product temperatures and years of out. — — — — trouble free service. DOORS ELECTRICAL REFRIGERATION SYSTEM • "Low -E ", double pane thermal • Unit completely pre -wired at factory • Factory engineered, self - contained, glass door assemblies with extruded and ready for final connection to a capillary tube system using aluminum frames. The latest in energy 115/60/1 phase 15 amp dedicated environmentally friendly (CFC free) efficient technology. outlet. Cord and plug set included. 134A refrigerant. • Each door fitted with 15" (381 mm) 115/60/1 • Extra large evaporator coil balanced long extruded aluminum handle. NEMA - - 15R with higher horsepower compressor • Positive seal doors. and large condenser; maintains cabinet • Magnetic door gaskets of one piece -- temperatures of 33 °F to 38 °F (.5 °C construction, removable without tools OPTIONAL FEATURES /ACCESSORIES to 3.3 °C). for ease of cleaning. Upcharge and lead times may apply. • Sealed, cast iron, self - lubricating • Door lock standard. 0 230 - 240V / 50 Hz. evaporator fan motor(s) and larger SHELVING 0 6" (153 mm) standard legs. fan blades give True merchandisers • Four (4) adjustable, heavy duty, black 0 6" (153 mm) seismic/flanged legs. a more efficient low velocity, high PVC coated wire shelves 31 "L x 0 2 (64 mm) diameter castors. volume airflow design. This unique 21 "D (807 mm x 540 mm). Four (4) 04" (102 mm) diameter castors. design insures faster temperature pull chrome plated shelf clips included per 0 Wine racks (left door only). down of warm product, colder holding shelf. 0 TrueTrac one (1) Liter beer and wine temperatures and faster recovery in . Aluminum shelf support pilasters. organizers. high use situations. Shelves are adjustable on 1 /2" (13 mm) 0 TrueTrac 12 oz. (355 ml) beer bottle • Condensing unit accessed from behind increments. organizers. front grill, slides out for easy cleaning LIGHTING 0 Remote cabinets (condensing units and maintenance. supplied by others; system comes CABINET CONSTRUCTION • Fluorescent interior lighting. Each standard with 404A expansion valve • Exterior - stainless steel front, sides door utilizes full - length, patented, and requires R404A refrigerant). integrated door light (IDL) system. Consult factory technical service and countertop. Matching aluminum Safety shielded. department for BTU information. back. • Cabinet lighting utilizes electronic • Interior - 300 series stainless steel floor ballast and T -8 bulbs for brighter with 1 /2" (13 mm) reinforced lip and illumination, longer bulb life and heavy gauge galvanized steel walls. increased energy efficiency. PLAN VIEW t t t A L ( 7 mm) >i 28 277/16" 271/16" (732 mm)(697 mm) (688 mm) 48 (1238 mm) 37" ! ; , t (940 mm) 1318" i 1 2121/37" (35 mm) ■ i . (551 mm) i 1111111■1 3" 14 (1709 ELEVATION ( mm) PLAN VIEW WARRANTY METRIC DIMENSIONS ROUNDED UP TO THE One year warranty on all parts NEAREST WHOLE MILLIMETER A Model Elevation Right Plan 3D and labor and an additional 4 KCL TBB -3G -S TFJY13E TFJY13S TFJY13P TFJY133 year warranty on compressor. SPECIFICATIONS SUBJECT TO CHANGE Whir (U.S.A. only) WITHOUT NOTICE - -- -- — — TRUE FOOD SERVICE EQUIPMENT St. Charles Industrial Center • P.O. Box 970 • O'Fallon, Missouri 63366 • (636)240 -2400 • FAX (636)272 -2408 • (800)325 -6152 • www.truemfg.com CENTURY SYSTEM POWER PAKS - WATER- COOLED Perlick Features MODEL NOS. ❑ 4404W Series • 1 /3, 1 /2 and 3 /4 HP 115 volt models. ❑ 4410W Series • 134a, constant pressure expansion ❑ 4414W Series valve and condensing unit with service valves. 0 CO • Adjustable electronic temperature Adjustable p control with digital readout. • High efficiency, compact heat exchanger provides more efficiency for longer beer runs. Horsepower Length of run 1 /3 150 feet 1 /2 300 feet 3 /4 500 feet Based on 75 degree ambient temperature. • Top mounted closed - coupled pump and 1 /3 HP ball bearing motor assembly for easy service. O 0 0 1 • Factory pre -mixed glycol guarantees performance. OO • Optional leg kit for free standing off the floor installation. • Optional multiple pump kits. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414- 353 -7060 • Fax 414- 353 -7069 lerlic Toll Free 800 - 558 -5592 • E -Mail: Penick @Perlick.com • www.Perlick.com Penick is committed to continuous improvement Therefore, we reserve the right to change specifications without prior notice. Sizes and Specifications Century System Job Power Paks Air - Cooled Item No. Model No. MODEL NOS. 4404 4410 4414 4414 230 4420 DIMENSIONS: Length "A" 24 (616) 24 (616) 24 (616) 26 (679) 26 (679) EXTERIOR (rnnri Width "B" 171/4" (438) 17 (438) 17 (438) 20 (519) 20 (519) Height "C" 25 (648) 25 (648) 25 (648) 31" (782) 31" (782) A minimum of six inches of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for above the unit and in front of the unit for serviceability. ELECTRICAL Voltage 120 V 120 V 120 V 208/230 V*** 208/230 V*** Freq. 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz Phase 10 10 10 10 10 SINGLE PUMP RLA 10.5 12.5 15.4 8.9 16.5 MCA 16.9 17.7 19.6 12.2 23.9 DUAL PUMPS RLA N/A 18.6 21.0 11.7 19.3 MCA N/A 23,8 25,2 15.0 26.7 TRIPLE PUMP RLA N/A N/A N/A 14.5 22.1 MCA N/A N/A N/A 17.8 29.5 COMPRESSOR: 1/3 HP 1/2 HP 3/4 HP 3/4 HP 1.5 HP EVAPORATOR RATING 2550 3800 6000 6300 12000 0 20 (BTUH) HEAT REJECTION (MAX) 4080 6080 9600 10080 19200 REFRIGERANT R -134a R -134a R -134a R -134a R -134a SHIPPING WEIGHT LBS (kg) 140 (64) 153 (69) 180 (82) 205 (93) 255 (116) MAXIMUM FOOTAGE IN SYSTEM 150 ft. 300 ft. 500 ft. 500 ft. 600 ft. (1000xx) (Based on 75 degree ambient) CABINET Stainless Steel CIRCULATING PUMP 100 GPH / 150 PSIG I RESERVOIR CAPACITY 1.75 gal 1 1.75 gal 1.75 gal 1 1.75 gal ) 1.75 gal REFRIGERATION: Constant Pressure Expansion Valve, Condensing Unit with Service Valves REFRIGERANT CHARGE (grams, 9.0 oz/255 g 8.0 oz/227 g 9.5 oz/269 g 14.5 oz/410 g 16.0 oz/453 g GLYCOL CONCENTRATION 33% 33% 33% 33% 33% OPTIONAL 4430 115V pump kit for 4410 power paks (Field Installed) 57782 Set of four adjustable legs ACCESSORIES 4431 115V pump kit for 4414 power pak (Field Installed)61790 Dual tier rack 4432 208/230V pump kit for 4414/230V and 61791 +1 Triple tier rack 4420 power paks (Field Installed) 61792 +2 Quad tier rack 4435 BLM receptacle C22296A -20 Cord It for 120V single pump power Paks only 4408SS Wall bracket for 4404 & 4410 only C21499BSS Stainless steel table stand *Note: Allow a minimum of six inches of clearance on the louvered ends of the cabinet for proper air Now. Allow accessability room on top and front of cabinet for serviceability. **Using two or three pump combinations. Above specifications are subject to change without prior approval. *'Requires four wires (2 hot, 1 neutral and 1 ground). 1/2" [13] I.D. OVERFLOW 1/2" [13] I.D. COOLANT 3" [76] OUTLET RETURN PORT 1/2" [13] I.D. COOLANT OUTLET PORT KIMIL T "B" ELECTRICAL CONNECTION I--- " f 4 1/2" 2 3/4" [45] } f [115] 11 7/8" i 1 $ $ 8 7/8" [303] ■ • _ I ® 0000 _ [226] f 10 7/8" 1 ,� [277] 1.1 •. 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414- 353 -7060 • Fax 414- 353 -7069 l e r t e z.: Toll Free 800 - 558 -5592 • E -Mail: Perlick @Perlick.com • www.Perlick.com Perlick is committed to continuous improvement Therefore, we reserve the right to change specifications without prior notice. Form No. 121701 Rev. 10.16.07 CENTURY SYSTEM POWER PAKS - AIR - COOLED Perlick Features MODEL NOS. ❑ 4404 Series • 1 /3, 1 /2 and 3 /4 HP 115V, and 3 /4, ❑ 4410 Series 11/2 HP 230 volt models. ❑ 4414 Series • 134a, constant pressure expansion ❑ 4420 Series valve and condensing unit with service valves. NSf. (2) • Adjustable electronic temperature control with digital readout. • High efficiency, compact heat exchanger provides more efficiency for longer beer runs. Horsepower Length of run 1 /3 150 feet 1/2 300 feet 3 /4 500 feet 11/2 1,000 feet w/ multi -pumps $ o u ao (600ft. max in one direction) Based on 75° degree ambient temperature • Top mounted closed - coupled pump 0 and 1/3 HP ball bearing motor assembly for easy service. . 401. • Factory pre -mixed glycol guarantees performance. • Optional leg kit for free standing off the floor installation. !� • Optional multiple pump kits. 1 ) 1 ic k 1 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414 - 353 -7060 • Fax 414 - 353 -7069 ter . Toll Free 800 - 558 -5592 • E -Mail: Perlick @Perlick.com • www.Perlick.com Pertick is committed to continuous improvement. There fore, we reserve the tight to change specifications without prior notice. .. Sizes and Specifications Century System Job Power Paks Water - Cooled Item No. Model No. MODEL NOS. 4404W 4410W 4414W DIMENSIONS: Length "A" 24 (616) 24 " (616) 263" (679) Width "B" 17 (438) 171/4" (438) 20 (519) Height "C" 25 (648) 25 (648) 31" (782) A minimum of six inches of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for above the unit and in front of the unit for serviceability. ELECTRICAL Voltage 120 V 120 V 120 V Freq. 60 Hz 60 Hz 60 Hz Phase 10 10 . 10 SINGLE PUMP RLA 9.7 12.7 13.4 MCA 17.8 19.9 20.4 DUAL PUMPS RLA N/A 15.5 16.2 MCA N/A 22.7 23.2 TRIPLE PUMP RLA N/A N/A N/A MCA N/A N/A N/A COMPRESSOR: 1 /3 HP 1 /2 HP 4/4 HP EVAPORATOR RATING 3420 4080 6870 0 20"F (BTUH) HEAT REJECTION (Max) 2050 2450 4122 REFRIGERANT R -134a R -134a R -134a SHIPPING WEIGHT LBS (kg) 141 (64) 143 (65) 205 (93) MAXIMUM FOOTAGE IN SYSTEM 150 ft. 300 ft. 500 ft. (Based on 75 degree ambient) CABINET Stainless Steel CIRCULATING PUMP 100 GPH / 150 PSIG RESERVOIR CAPACITY 1.75 gal 1 1.75 gal 1 1.75 gal REFRIGERATION: Constant Pressure Expansion Valve, Condensing Unit with Service Valves REFRIGERANT CHARGE (grams) 14.5 oz/410 g 14.5 oz/410 g 22.0 oz/623 g GLYCOL CONCENTRATION 33% 33% 33% PLUMBING REQUIREMENTS INLET & OUTLET All employ 1/2 " O.D. Quick Connect Fittings FLOW RATE (gpm) 0 75°F 0.5 0.6 0.9 PRESSURE DROP (psig) 0.1 0.2 0.4 MAX SUPPLY PRESSURE All Models: Incoming Water Pressure not to exceed 150 psig. OPTIONAL 4430 115V pump kit for 4410 power paks (Field Installed) 61790 Dual tier rack ACCESSORIES 4431 115V pump kit for 4414 power pak (Field Installed) 61791 +1 Triple tier rack 4435 BLM receptacle 61792 +2 Quad tier rack 4408SS Wall bracket for 4404 & 4410 only C22296A -20 Cord kit for 120V single pump power paks only 57782 Set of four adjustable legs C21499BSS Stainless steel table stand 54838 Water hammer arrestor (add if incoming water Is under 65 °F) 'Note: Allow a minimum of six inches of clearance on the louvered ends of the cabinet for proper air flow. Allow accessability room on top and front of cabinet for serviceability. Above specifications are subject to change without prior approval. 1/2" [13] I.D. COOLANT OUTLET PORT 1/2" [13] I.D. OVERFLOW 1/2" [13] I.D. COOLANT 3" [76] OUTLET RETURN PORT illlir - T " i ELECTRICAL I� CONNECTION 1--- "A' —•-1 12 1/2" - 23/4" [45] 1 — [319] 11 7/8" I 1 1 [303] 8 7/8" IMI _I Cl soon _ [226] 1: f 10 7/8" i■ i [ l ilt " WATER l '-------------=---'=.--------- 2"151] INLET -7 1 3/4" WATER ' — [45] �• OUTLET 161 [414] 1 i 8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414 - 353 -7060 • Fax 414 - 353 -7069 eY s Toll Free 800 - 558 -5592 • E -Mail: Perlick @Perlick.com • www.Perlick.com Penick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. 121601 Rev. 05.03.08 , j 7l y A!A # TRUE FOOD SERVICE Project Name: w EQUIPMENT, INC. Location: 2001 East Terra Lane • P.O. Box 970.O'Fallon, Missouri 63366 VS # (636)240 -2400 • Fax (636)272 -2408 • (800)325 -6152 • Intl Fax# (001)636-272-7546 Item #: Qty: Parts Dept. (800)424 -TRUE • Parts Dept. Fax# (636)272 -9471 • www.truemfg.com Model #: Model Glass and Plate Chiller /Froster: T 24 -GC -S Solid Lid, Stainless Steel Exterior T 24 -GCS ► True's glass and plate chiller/frosters are designed with enduring quality "' i and value. Our commitment to ., '44,4 4. ,° .; " , using the highest quality materials —ma and oversized refrigeration assures colder product temperatures and years of trouble free service. 1+ ► Large storage capacity to meet the supply and demand requirements during peak hours. ► Oversized, factory balanced, refrigeration system holds 0 °F (- 17.7 °C) and below. ► Forced -air cooling, positively guided i ( airflow provide efficient balanced temperatures throughout the cabinet. This unique design ensures fast frosting of dry glasses and plates. R ► Exterior - all stainless steel countertop, lid, front and sides. Matching aluminum back. � _ I ► Interior - long lasting, heavy duty s„„ galvanized steel. ► Evaporator - epoxy coated at the time of manufacture to eliminate the potential of corrosion. ►Entire cabinet structure and lid are foamed -in -place using high density, CFC free, polyurethane insulation. 0 Heavy duty, 10 mil thick pure grade PVC coated adjustable shelves. ROUGH-IN DATA Specifications subject to change without notice. Chart dimensions rounded up to the nearest 1 /e" i psi , x Capacity Cabinet Dimensions - T - (i nches) Cord Crated 8 Lengt • We ight ,304 min 1 10 0Z " ") NEMA (total ft.) (lbs.) Model Lids Mugs Steins Shelves 24 } 26s / 33 /e HP a� 1 S/60/1 Amps 8 s C 5 15P 9 ,, 18, 0 T-24-GC-S 1 9 � ■ 1 5 i h'7 ' 848 / 2 -Ci !40l$0l9 I 7 1 i i f . 4 i t Depth does not include 1 ,/ ,r,i for rear bumpers. A Plug tvf,,• ti ,311c `'„ G ®� APPROVALS: AVAILABLE AT CE MUTH. 21 USA 1/08 Printed in U.S.A. Model: Glass & Plate Chiller /Froster: T 24 -GC -S Solid Lid, Stainless Steel Exterior J STANDARD FEATURES DESIGN CABINET CONSTRUCTION ELECTRICAL • True's glass and plate chiller /frosters • Exterior - all stainless steel countertop, • Unit completely pre -wired at factory and are designed with enduring quality and lid, cabinet front and sides, matching ready for final connection to a 115/60/1 value. Our commitment to using the aluminum back. phase - 15 amp dedicated outlet. Cord highest quality materials and oversized • Interior - long lasting, heavy duty and plug set included. refrigeration assures colder product galvanized steel 115/60/1 temperatures and years of trouble free • Insulation - entire cabinet structure is NEMA -5 -15R service. foamed -in -place using high density, CFC free, polyurethane insulation. • REFRIGERATION SYSTEM • Welded, heavy duty galvanized base rail OPTIONAL FEATURES /ACCESSORIES • Factory engineered, self-contained, U char a and lead times may apply . capillary tube system using dipped in rust inhibiting enamel paint ° 230 -240V / 50 230-240V y environmentally friendly (CFC free) 404A for corrosion protection inside and out. refrigerant. SHELVING O 6" (153 mm) standard legs. g 0 6" (153 mm) seismic/flanged legs. • Two (2) ad • Extra large evaporator coil balanced adjustable, heavy duty PVC O 2 (64 mm) diameter castors. with higher horsepower compressor coated wire shelves 10 "L x 195/16 "D O 3" (77 mm) diameter castors. and large condenser; maintains cabinet (261 mm x 491 mm). Split shelf design O Ratchet lock and handle. temperatures of 0 °F (- 17.7 °C) and below. allows for effective rotation of chilled O Floor racks. • Sealed, cast iron, self- lubricating smallware, working with already chilled O Additional shelves. evaporator fan motor(s) and larger fan plates and glasses on one side while 0 Remote cabinets (condensing unit blades give True chiller / frosters a more chilling dry product on other side. supplied by others; system comes efficient low velocity, high volume MODEL FEATURES standard with 404A expansion valve and airflow design. This unique design • Evaporator is epoxy coated to eliminate requires R404A refrigerant). Consult ensures fast frosting of dry glasses and the potential of corrosion. factory technical service department for plates. • Listed under NSF -7 for the storage BTU information. • Automatic defrost system time- initiated, and/or display of packaged or bottled time- terminated. product. • Condensing unit accessed from behind front grill, slides out for easy maintenance. • Forced -air cooling, positively guided airflow provide efficient balanced temperatures throughout the cabinet. PLAN VIEW 27 " . le (701 mm) .4_ 26 l . 4 1 " (675 mm) (26 mm) 2 . . . 24 12 " � (70 mm) I (629 mm) (51 "m I (324 mm) ) T 1 ' 27 333/8" ,F t9 + /e "a"r (701 mm) (848 mm) ( 466 mm) , 8 (226 mm) r 1 J` I 221/8" -- ) 8 .I 3 h6" �� (562 mm) (78 mm) Elf_ VA RIGHT VIEW PLAN VIEW WARRANTY METRIC DIMENSIONS ROUNDED UP TO THE _ 1 levation r RI Plan 3D One year warranty On all parts NEAREST WHOLE MILLIMETER K L T ^ 2 (evat( E TFLY015 TFLY03P TFLY033 ea labor and o n coe 4 year warranty on comprmpressor. SPECIFICATNIO ROUT NoTICO CHANGE 4 GCS E� —+- y ,, ( only) TRUE FOOD SERVICE EQUIPMENT 2001 East Terra Lane • P.O. Box 970 • O'Fallon, Missouri 63366 • (636)240 -2400 • Fax (636)272-2408 • (800)325 -6152 • Intl. Fax# (001)636- 272 -7546 • www.truemtg.co+n Item No. Quantity BEVERAGE -AIR MODELS: PO Box 5932, Spartanburg, SC 29304 DEEP & SHALLOW WELL DW49 1 -888 -845 -9800 Fax# 1 -864- 582 -5083 HORIZONTAL COOLERS DW64 http: //www.Beverage- Air.com DW79 DW /SF SERIES DW94 Commercial Refrigeration Equipment SF34 General Specification DEEP & SHALLOW WELL — HORIZONTAL BOTTLE COOLERS Deep Well horizontal coolers include 4 (four) self- contained models in widths of 50 ", 65 ", 80" and 95 ". One shallow well model (SF34) is available in width of 35 ". CABINET CONSTRUCTION Exteriors of both deep well and shallow well models include attractive, wear - resistant vinyl on steel in black finish. Stainless steel options are available. Bottle cap opener and cap catcher is standard with all models. DW49 - Tops of both deep well and shallow well models include easy glide, stainless steel lids and stainless steel counter top with 746 m= integral glass stops. Optional glass lids, when specified, come with interior lighting. Lid locks are optionally available. Standard interior metal is galvanized steel. Stainless steel interior is optionally available. Adjustable dividers included are epoxy coated steel wire. DW64 - B Environmentally friendly foamed -in -place CFC and HCFC -free polyurethane insulation enhances the structural strength of the cabinet and helps increase energy efficiency. REFRIGERATION Forced air refrigeration systems provide ample capacity to chill and hold products between 32 °F and 38 °F. Refrigerant R134a used in systems is CFC and HCFC -free for compliance to envi- ronmental safety concerns. Condensate elimination is auto- matic and non - electric. DW79 -B ELECTRICAL Units wired at factory and ready for connection to a 115/60/1 phase, 15 amp dedicated outlet. 8' long cord and plug set included. SPECIAL FEATURES • DW79, DW94 standard models have earned the ENERGY STAR ® . Does not apply to remote or glass lid models. DW94 -B (2) c (2, us �� _u ,r, p � Available From: USA 'Note: Not all markings may apply to all model variations Model Specified Store# Location Quantity ELECTRICAL CONNECTION 03, , BEVERAGE -AIR Units pre -wired at factory and include 8' ",,` long cord and plug set. Deep & Shallow Well Horizontal Bottle Coolers 115/60/1 Models: DW49, DW64, DW79, DW94, SF34 NEMA -5 -15P - MODEL DW49 OW04 OW79 DW94 SF34 PLAN VIEWS EXTERNAL DIMENSIONAL DATA _ 5()^ Length Overall (inches) 50" 65' 80' 95" 35° 1r -_ -- <s Length Overall (mm) 1270 1651 2032 2413 889 . - - • '1 1 Depth Overall (inches) 26 1/2' 26 1/2" 261/2' 26 1/2' 26 1/2' } Depth Overall (mm) 673 673 673 673 673 27' INSIDE HT :_ JF F? L Height Overall— (Inches) 33 7/8" 33 7/8" 33 7/8" 33 7/8' 33 7/8' pl HaigMCverall —(mm) 860 860 860 860 860 M r_ 31 -' Number of lids 2 2 3 4 1 I 1 INTERNAL DIMENSIONAL DATA NET Capacity (cubic ft.) 13.35 18.48 24.1 29.5 7.5 DW49 FRONT NET Capacity (Liters) 378 523 882 835 212 Internal Length Overall (inches) 46" 61' 76' 91" 31" Internal Length Overall (mm) 1168 1549 1930 2311 787 65' vvl:T Internal Depth Overall (inches) 22 1/2" 22 12° 22 1/2' 22 1/2" 22 1/2" FRONT Internal Depth Overall (mm) 572 572 572 572 572 1 .. _ I 1 Internal Height Overall (inches) 27" 27" 27" 27° 18 12" Internal Height Overall (mm) 686 686 688 686 470 27' INV., Number of dividers 3 4 5 6 2 I "{' 12 oz. bottle capacity 17 1/2 cases 25 1/4 cases 32 cases 39 cases 9 1/3 cases BOB _......1...... I I 1 t 12 oz. can capacity 23 3/4 cases 34 3/4 cases 45 3/4 cases 55 3/4 cases 11 12 cases I - ELECTRICAL DATA Full Load Amperes 115/60/1 6.3 6.3 9.5 9.5 4.5 DW64 FRONT ENERGY CONSUMPTION (KWH) 3.0 3.52 3.77 4.32 4.4 FRONT REFRIGERATION DATA 80 _; Horsepower 1/3 1/3 1/2 1/2 1/5 } r, - _ i . ,- WEIGHT DATA , 33 7/8 27 IV:, u M Gross Weight (Crated Ibs) 259 296 379 425 200 Gross Weight (Crated kg) 118 134 172 193 91 =$10 Iiill�r _I. _. _._.. 1 el) c us c la ( NSF) "vL ( (y.„„ DW79 FRONT USA *Note: Not all markings may apply to all model variations. END 1" 35 f FRONT 26 1 /2 , 95 — ■ - _ —1- - -- r,; did , I L_______... 3 ! � 27" �" INSIDE 1 + ' 18 1,��' w � lot- H 22 1/2" 3 7l8" n8" /INSIDE. • 33 i t DEPTH .J'_ o — — -- - 1 COMMON END MIN NON l l FRONT SF34 FRONT DW94 FRONT BEVERAGE-AJR CORPORATION 700 Buffington Road • PO Box 5932 • Spartanburg, SC 29304 USA • (864) 582 -8111 • Fax (864) 582 -5083 • (888) 845 -9800 • wwwbeverage- air.com Specifications are subject to change without prior notice. 06/09 Standard Bar Sinks i(r owne Model: Item #: Quantity: I Project: Q • Sink Bowl: - -c 20 gauge 304 series stainless steel 10" x 14" x V, 9 3/4" deep. 1 1/2" radius on all vertical and �+ ,: horizontal corners. Furnished with 1" stainless Ta steel drain and 7 1/2" standpipe. Drain located •■■,• , " E in left rear corner. b x e • Drainboard: 1 ` ` 20 gauge 304 series embossed stainless steel ji reinforced with welded braces every six inches. 3/4" radius on all vertical and horizontal edges. • Front Apron: 22 gauge 304 series stainless steel clad over 20 gauge galvaneal. Y 1800 or 2100 Series Available (see reverse) — • Backsplash: 22 gauge 304 series stainless steel. • Sides: 20 gauge galvaneal. • Back and Bottom: 20 gauge galvaneal. • Legs: 1 5/8" tubular 16 gauge galvanized steel with grey plastic bullet foot. Accessories • Water Faucet: ❑ Standard Single Tier Keyhole Speedrail 4" center splash mount faucet on 1800 models. (available sizes: 24 ", 30 ", 36 ", and 48 ") 4" center deck mount faucet on 2100 models. ❑ Standard Double Tier Keyhole Speedrail • Plumbing: (available sizes: 24 ", 30 ", 36 ", and 48 ") 1/2" IPS hot and cold water ❑ Waste Manifold 1" IPS drain connection ❑ Perforated Basket ❑ 1800 and 2100 Corner Return ❑ Side Splash ❑ Towel Ring ❑ Additional Accessories (see Accessory Sheet) ❑ Stainless Steel Legs Approved By: 1— owne Me tal Corporation Phone: 800- 631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973-485-1424 02/05 www.krowne.com sales@krowne.com 4.4 --4 -- Standard Bar Sinks owns Model: Item #: Quantity: Project: Cm 1800 Series Model Length Bowls Drainboard Left Side Weight ® Numbers to Drain Ibe e) im IT) ® ® ® © _ :-:".z D D D _ _ -- 1 18-310 3' 0" 1 12" each 16" 48 - = 16.125 18.5• 18-32L 3-0" 2 12" right 4" 53 - _ = – – 18-32R 2' -0" 2 12" left 15" 53 _ _ ■ ■ i ■ / _ 7. _ _ _ i 1 18 4 2 24" right 4" 55 18-42R 4-0" 2 24" left 27' 55 18-420 4-0" 2 12 " each 15' 55 1 18-33 3-0" 3 Na 4" 55 14• 18-43L 4-0" 3 12" right 4" 60 r ---- ' r--- 18-43R 4-0" 3 12" left 15" 60 11111•111111•1111•11111`■11111•1111M111111111111111 18-530 5-0" 3 12' each 15" 69 -1,— n I , - 11 r i f 9. • 11111 18 630 6' -0' 3 18" each 21" 75 to ' ' 1 1188:763300 8 730 7' -0" 3 24" each 27" 86 (f Tom' ...... I 33 ' 18-830 8' -0' 3 30" each 33" 94 30 � 18640 6' -0' 4 12' each 15" 79 I (i 12• 12 ' -- i 18-740 18-840 7' -0" 4 18'each 21" 91 8' -0" 4 24" each 27" 99 ' Units with a 10" x 14" x 7" deep bowl 2100 Series Model Length Bowls Drainboard Lett Side Weight Numbers to Drain Ibs cl �l rl ® © 1111:� ___E 2.5' '21 -10 1' -0' 1 Na 6" 43 _ _ } 21 -310 3-0" 1 12" each 16" 51 _ _ _ - "` _ _ 16.125. 21 21 -32L 3-0" 2 12" right 4' 56 :::3.7 21-32R -0" 2 12' left 15" 56 __ _ 1 2' 21-42L 4-0" 2 24 " right 4' 58 21-42R 4-0" 2 24' left 27" 58 21-42C 4-0" 2 12" each 15" 58 53 14 21-431 4-0" 3 12" right 4" 63 11111111.1111r�— r -- r 21-43R 4-0" 3 12" left 15" 63 li 21 -530 5' -0" 3 12"each 15' 75 o L to• -1 r 9 , 21 -63 6' -0" 3 "' 85 ' ' ' ' ' 1_ 21 - 730 7' -0" 3 24 each each 2 95 • • • 34.5' 30 � " 21-83C 8' -0" 3 30'each 33' 104 I (0 12' -12• - 21 -84C 6' -0" 4 12" each 15" 88 7' 21 -740 -0" 4 18" each 21' 100 21 840 8' -0" 4 24" each 27' 109 ' Units with a 10" x 14" x 7" deep bowl — Mechanical Requirements: — 1/2" IPS Hot and Cold Water. Approved By: 1" IPS Drain Connection. Due to our commitment to continued product improvement, specifications are subject to change without notice. 107 Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973 02/05 www.krowne.com sales @krowne.com 044 -1(1, owns Royal Liquor Displays Model: Item #: Quantity: 0 c il Project: • Bottle Steps: 20 gauge 304 series stainless steel. CD ■ , rm • Guardrails: � ■ q " t! h CD c 20 gauge 304 series stainless steel. R r • Backsplash: . #'° 1 20 gauge 304 series stainless steel. • Sides: 18 gauge 304 series stainless steel. • Back and Bottom: 20 gauge 304 series stainless steel. • Legs: 1 1 5/8" tubular 16 gauge stainless steel with grey thermoplastic bullet foot. 1800 or 2100 Series Available — (see reverse) Accessories ❑ Locking Cover Approved By: 4111111111111111111111111111111111111111 I(ro". e Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973 -485 -1424 02/05 www.krowne.com sales @krowne.com 5.21 k rowne Royal Liquor Displays Model: Item #: Quantity: Project: 1800 Series 4.5' Model Overall Bottles Weight 24' Numbers Length Stored Ibs. KR18 -12RD 1' -0' 16 30 KRIS-18RD 1'-6' 24 35 1 KR18 -24RD 2' -0• 32 40 r ® - 24'--1 l 36.5' 1 3 I 18.5' I 24.2a75. 1 11 1. S519 2100 Series a 1 Model Overall Bottles Weight 4.5' 26• —r 1 Numbers Length Stored lbs. 0 KR21 -12RD 1' -0' 16 30 KR21 -18RD 1'-6' 24 35 KR21-24RD 2' -0' 32 40 —�'— - 26, I 11..5' 36.5' T 30' 1 24.5•22.75. 21 19.25. s z 1 1 1 t . Approved By: Due to our commitment to continued product Improvement, specifications are subject to change without notice. 116 1111MMEMOMIN �wne Metal Corporation Phone: 800 - 631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973-485-1424 02/05 www.krowne.com sales @krowne.com i ,liki Standard Ice Bins owns Model: (h Item #: Quantity: 0 Project: 0 aku cn • Interior: M 20 gauge 304 series stainless steel with 3/8" � • radius corners welded and sealed. Available in 8 ", 12" and 15" depth. (1) • Cold Plate: Cast aluminum post mix plate with seven cir- cuits. Plate is sealed into bottom. Each circuit , ! • is 5/16" OD stainless steel tubing. Two full with remainder to be half curcuits. Bump and swedge fittings on ends. r 1800 or 2100 Series Available • Front Apron: (see reverse) _ 22 gauge 304 series stainless steel clad over 20 gauge galvaneal. • Backsplash: 22 gauge 304 series stainless steel. • Sides: 20 gauge galvaneal. • Back and Bottom: 20 gauge galvaneal. Accessories • Legs: ❑ Standard Single Tier Keyhole Speedrail 1 -5/8" tubular 16 gauge galvanized steel. Each (available sizes: 24 ", 30 ", 36 ", and 48 ") leg to have grey plastic bullet foot. ❑ Standard Double Tier Keyhole Speedrail (available sizes: 24 ", 30 ", 36 ", and 48 ") • Plumbing: ❑Upgrade to Eight Circuit Cold Plate 1/2" IPS drain connection with cold plate (4" ❑ Stainless Steel Divider (specify ice bin model) nipple provided). ❑ Perforated bottom (on units without cold plates) 1 " IPS drain connection without cold plate. ❑ Stainless Steel Sliding Cover (specify ice bin model and if bottle holders are bring used) ❑ Condiment Tray ❑ 3 —Well Bottle Holder (two included with all ice bins) ❑ Stainless Steel Legs ❑ Additional Accessories (see Accessory Sheet) Approved By: I Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973 - 485 -1424 02/05 www.krowne.com safes @krowne.com 4.2 4te Ammilimmm Standard Ice Bins owns 0 0 r Model: Item #: Quantity: Project: 3 1800 Series ha Model Length Bin Overall Left Side Inside Cold Ice Leg Weight Numbers Depth Depth to Drain Bin. Dim. Plate Capacity She lbs ihiere ® 1 ® ® © 0 Circuits lbs O 1880 2' -0" 8' 9.5" 12" 15 "x22" - 55 20" 45 1880-36 3'0" 8" 9.5" 18" 15'x34" - 77 20" 70 -} p 1 16.12318.5" 8' 1880 -7 r -0" 12.5" 12" 15" x 22" 7 55 17" 80 1880-36-7 3' -0" 8" 12.5" 18" 15 "x34" 7 77 17" 105 =a 18 -24 2 -0" 12' 13.5' 12" 15' x 22" - 80 16" 50 0 18-30 2' 6" 12" 13.5' 15" 15 "x28" - 97 16" 65 18.5• 18-36 3' -0" 12" 13.5" 18' 15" x 34" - 115 16" 80 18 24-7 2' 0" 12" 16.5" 12" 15" x 22" 7 80 13" 85 18-30-7 2' 6" 12" 16.5" 15" 15" x 28" 7 97 13" 100 1 18 -36 -7 3' -0" 12" 16.5" 18" 15 "x34" 7 115 13" 115 o i i ; 18 -24DP 2-0" 15" 16.5' 12" 15" x 22° - 100 13" 65 O ' ' 18 -30DP 2-6" 15" 16.5" 15" 15" x 28" - 120 13" 80 II --- --- _' 33• T --n--r 18 -36DP 3' -0" 15' 16.5" 18" 15 "x34" - 138 13" 95 nmm�nomr 30• - -r 18- 24DP -7 2' -0' 15' 19.5" 12" 15 "x22" 7 100 10" 100 ' i , © , I 18- 30DP -7 2' -6" 15" 19.5" 15" 15" x 28" 7 120 10" 115 I 18- 36DP -7 3' -0" 15' 19.5' 18" 15 "x34" 7 138 10" 130 2100 Series Model Length Bin Overall Left Side Inside Cold Ice Leg Weight Numbers Depth Depth to Drain Bin. Dim. Plate Capacity Sire lbs I ® 2180 ® ® © 9.5" © 12" 15 "x22" Circuits O 2 .5 ' 2180 -36 3' -0" 8" 9.5' 18" 15'x34" - 77 20" 80 4-D 16 2 1 2180-7 2'•0' 8" 12.5" 12" 15' x 22' 7 55 17' 90 I 2180-36-7 3' 0" 8" 12.5" 18" 15 "x34" 7 77 17" 115 21 -24 2-0" 12" 13.5° 12" 15' x 22" - 80 16" 60 21-30 2-6" 12" 13.5" 15" 15" x 28" - 97 16' 80 2t• 21-36 3' -0" 12' 13.5" 18" 15 °x34" - 115 16" 100 21-24-7 2-0" 12" 16.5" 12" 15" x 22" 7 80 13' 95 21-30-7 2' 6' 12" 16.5' 15' 15" x 28" 7 97 13' 115 --- 7, 21-36-7 3' 0" 12" 16.5" 18' 15 "x34' 7 115 13" 135 21 -24DP 2-0" 15" 16.5" 12' 15" x 22" - 100 13" 75 T_ - _ 1 5 © ; 21 -30DP 2' -6' 15" 16.5" 15" 15" x 28" - 120 13" 95 T - -n - -r 21.36DP 3' -0" 15" 16.5" 18" 15 "x34" - 138 13" 115 tinlmnnnrtmJ 30• --+--r to 1 1 21- 24DP -7 2-0" 15' 19.5" 12" 15 "x22" 7 100 10" 110 © 21- 30DP -7 2'-6" 15" 19.5" 15" 15" x 28" 7 120 10" 130 21- 36DP -7 3' -0" 15" 19.5' 18" 15 "x34" 7 138 10" 150 a Mechanical Requirements: - 1" IPS Drain Connection without Cold Plate. - 1/2" IPS Drain Connection with Cold Plate. Approved By: Due to our commitment to continued product improvement, specifications are subject to change without notice. Ic hill1111111111 owne • Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 02/05 www.krowne.com sales@krowne.com FAX: 973-485-1424 -7 7 - icy owns Royal Multi Stations Model: Item #: Quantity: (3) I iiii Project: • Cold Plate (optional): Cast aluminum plate with eight circuits. Plate is it sealed into bottom. Each circuit is 5/16" O.D, stain- less steel tubing. Two full with remainder to be half �� circuits. Bump and swedge fittings on ends. ' • Tubing Access: 0 isor �; 3/4" x 3.5" cutout in left side of backsplash on cold '' plate unit (1800 series). 1/2" x 4.3" cutout in left side of backsplash on cold plate units (2100 series). I' . Legs: 1 I 1 5/8" tubular 16 gauge stainless steel with grey thermoplastic bullet foot. • Interior: 20 gauge 304 series stainless steel. 12" deep 1800 or 2100 Series Available _ ice bin section, 10" deep bottle section. (see reverse) • Front Apron: 20 gauge 304 series stainless steel clad over 20 gauge gaivaneal. • Backsplash: 20 gauge 304 series stainless steel. Accessories • Back and Bottom: O Built -in 20 gauge Sound Deadened Krowne Royal 20 gauge gaivaneal. Single Speedrail ❑ Built -in 20 gauge Sound Deadened Krowne Royal • Sides: Double Speedrail 20 gauge 304 series stainless steel. O Stainless steel sliding cover • Insulation: ❑ Eight Circuit Cold Plate Foam in place polyurethene. ❑ Ten circuit cold plate upgrade ❑ Condiment Tray • Plumbing: ❑ Stainless Steel Divider 1/2" IPS drain connection with cold plate. ❑ Towel Ring 1" IPS drain connection without cold plate. ❑ Side Splash (specify left or right) Note: Cold Plate Unit supplied with 1/2" x 4" ❑ Cap Catcher and Opener threaded PVC pipe. ❑ 15" deep liner on Ice Bin Approved By: h l (r owne Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX 02/05 www.krowne.com salesekrowne.com FAX: 973-485-1424 5.7 ...,. , . , .. _. —1 ur owns Royal Multi Stations Model: Item #: Quantity: Project: � t:t : 1800 Series 0 12 Model Length Ice Bin Ice Bin Bottles Ice Bin Cold Plates Ice Weight Numbers Length Location Stored Drain Circuit Capacity Ibs OA © © � D r t 5 ts _ KRI8 -M36R 3' -0" 24' Right 6 24" n/a 80 95 . rill ! K M36R -8 V-0" 24' Right 6 24" n/a 80 172 KR18- M36L -8 3'0" 24° Left 6 12' 8 80 172 r © J KR18 -M42R 3'-6" 30" Right 6 27" n/a 97 108 KR18 M42L 3.8' 30" Left 6 15" n/a 97 108 KR18 M42R 8 3' -6' 30' Right 6 27" 8 97 185 KR18- M42L -8 3' -6" 30" Left 6 15" 8 97 185 KR18 -M48C 4'-0' 24" Center 12 24" n/a 80 116 11.5' El KR18 -M48R 4'0' 36" Right 6 30' n/a 115 116 36.5' KR18 -M48L 4'-0' 36" Left 6 18" n/a 115 116 u —ten 30' KR18- M48C -8 4' -0" 24" Center 12 24" 8 80 193 1 L I I KR18- M48R -8 4'-0" 36' Right 6 30" 8 115 193 1 KR18-M48L-8 4'-0" 36' Left 6 18" 8 115 193 I O pliOi W BuNHn Cold Plate 2100 Series 0 Model Length Ice Bin Ice Bln Bottles Ice Bin Cold Plates Ice Weight 12' _ t� 2.5• Numbers Length Location Stored Drain Circuit Capacity Ibs ___ 1 0 ® © Ibs 1( � I KR21 -M36R 3'-0" 24" Right 6 24" n/a 80 95 . J +0 16 21' KR21 -M36L 3'-0' 24" Left 6 12' n/a 80 95 i KR2 Right KR21-M36L-8 3'0' 24' Left 6 12' 8 80 172 KR21 -M42R 3'-6' 30" Right 6 27' n/a 97 108 ® 1 KR21 -M42L 3'-6' 30" Left 8 15" n/a 97 108 KR21-M42R-8 3' 6" 30" Right 6 27" 8 97 185 -_. KR21 M42L 8 3'-6" 30" Lett 6 15° 8 97 185 T--011-2-1 KR21 -M48C 4' -0' 24" Center 12 24" n/a 80 116 R 115• KR21 -M48 L 4'-0" 36" Right 6 38" n/a 115 116 1. KR21 -M48L 4'0' 36" Left 6 18" Na 115 116 �1�� 36.5' KR21- M48C -8 4' -0" 24" Center 12 24' 8 80 193 ll�l, 1,,,�1 "�' 30• KR21- M48R -8 4' -0' 36" Right 6 30' 8 115 193 1 t4 KR21- M48L -8 4' -0" 36" Left 6 18" 8 115 193 Optional Bullt -In Cab Plate Mechanical Requirements: Approved By: 1" IPS Drain Connection without Cold Plate. 1/2' IPS Drain Connection with Cold Plate. Due to our commitment to continued product improvement, specifications are subject to change without notice. I (r own e Metal Corporation Phone: 800 -631 -0442 257 Verona Ave. Newark, New Jersey 07104 FAX: 973-485-1424 02/05 www.krowne.com saIesfitkrowne.com BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlanti - { ?233 1p It Office (904) 24 Fax (904) 247 -5845 Job Address: 3 s9 iP. >9 77-49V776 f74 3zZ33 Permit Number: A " c 0/ 9 Legal Description 0'" d A ' fl,--E" d-l•C O55 7We e7N Parcel # Valuation of Work ZSD oao ' oor rea o q. t. / Proposed Work heated /cooled � AD ' a ji, ,r, Class of Work (circle one): New Addition Alteration Repair Move Demo!' r (/J� Use of existing /pro p re osed structu pool/spa window`Tdo� fs) (circle one): Residentia /WA Y O If an existing structure, is a fire sprinkler system inst. a Florida Product Approval # one): Y es N fA 2 2011 For multiple products use pro uct al---E---W-m•--n-ova orm &Y 1 Describe in detail the type of work to be performed: /A/reWO,e p - ` N 1 / ` N - " - PGoilet/Y 61/&-X ' ', . "WO - A'Z' r/f7sYTTA/9, Property Owner Information: T' Name: 44: C City — — _, _— Address: State —Zip Phone E -Mail or Fax # (Optional) - - --- -_ _______ s Contractor Information: -- — • len Company Name: //, qn/, fy8 eNST7jjON ac 1 V;di....4, �- Address: f2-30 PRj3�p P�'O�C-SStgy�GT ,�.,, Qualifying A gent: �j>. (/�(/,pD� "?y� Office Phone -n`� Numb F � z _ Sta(e — cF A ko (9�)z7o' ZzZS Job Site/ �'ontact Numbe -� - - Zip - �� / l! IC State Certification /Registration # #F /57657f ' F ax # Architect Name & Phone # de -A 03f32749--4002. — �_.._ -_ . Engineer's Name & Phone # .— — Fee Simple Title Holder Name and Address __ Bonding Company Name and Address _-- _.-.._— Mortgage Lender Name and Address -- - -- _ Application is hereby made to obtain a permit to do the war k and installations as indicated. / certify thud no work or installation has commenced rior to the issuance ofa permit and that all work will he performed to tweet the standards of all laws regulating cronst uction in this jru•isdtction. 7 hi,s permit becomes null and void if work is not commenced within sir (6) months, or if construction or work is suspended or abandoned for a period of sir (6) months at any time after wank is commenced r Conditioners, 'unde e that separate permits must he secured for Electrical Work, Plumbing, Signs. Wells, Pools, Furnaces, Boilers, Heaters, warksaceAft l tc. c. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOT E OF COMMENCEMENT, I hereby cer ibm 1 hare read and examined this gpplicatimt and know - .ante 10 he true and correct. All prowsio of laws nd r (finances • ' type of work well be complied with whether sp�recr /red herein or no ne granting of a permit sloes not presume o • cite 0 bar, , to viol 0 is provisions of any ether federal state. or local law r' -. action or the performance of urhnn. / � J re Al Signature of Owne� /' / " � Signature of Contractor Print Name � 0 .. /t _ �t lDt �ihl� � _ � . Print Name 4:P g �j 9.01Y 4.41 % /' - Sworn to and subscribed before me % `0 . t �� , Sworn to and subset c Before me this :?..2 Day of �0 this U y of j - 2.•"„ Q i2 Q .„ -.(2 Notary Public — _ Notary q i.ij IC i i v (eiWeia;t¢ .10 MICHELLE KAY PRICE DALE •.l. LEWIS ` av"` Comma DD0807477 Notary Public P ,,5 AU. !Z GOIMIONWEALTM OF wi8dACiNmETTB ( g. •E Expires 11/7/2012 November 'Igri ' ,, Florida Notary Assn., Inc �- -- �- —• -- tb P Swm�V.4•.S�i ' FILE COPY ., {� %M'4_ ? ° ... f ro +`,M : .yrr�p., ml� t LJ-V. r; City of Atlantic Beach q 'LIGATION NUMBER e p , Building Department = (To be assigned the Building Department ) 3. i 800 Seminole Road " T t 7 a : Atlantic Beach, Florida 32233 -5445 A � �` �C F•T� �^ Phone (904) 247 -5826 • Fax (904) 247 -5845 try x a� rt , tt �,:0 E-mail: building- dept@coab.us � Date %uted ny +� a *F City web -site: hftp: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 36 �a�i /vd/ D review re Ye No V Building,) A pl icant: bib t- 7� /�Q A f� i ,� - pu O r unning & Zoning p C1� � //�� J Tree Administrator Project: /?7 // 6 /V L(d (- £ Public Works Public Utilities Public Safety Fire Services R "ixc err �x+ R . s. 'A ZaSm#A rcr' spkld�YRia C•4.A613zi u., r ri &2�+ ° -r a evlew ee $ ,. : , 7......:: igif eP. !9. „attr �, ' M zL4.'': A 3 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. (Circle one.) Comments: �-� f j )1 1 t0-P p },, Afro va 1. BUILDING PLANNING & ZONING Reviewed by: iii C Date: c- 5- ^I/ TREE ADMIN. Second Review: ❑Approved as revised. ❑ vied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. (Denied. Comments: Reviewed by: Date: Revised 05/14/09 v .SON Vi one JacksonvilleFirePrever E � 1144?) MAY 17 2011 ° R eP ; ---p F SCUE � 0 EXCEMONSASRM PREVENTION DIVISION OFFICE OF PLAN REVIEW May 9, 2011 TO: Atlantic Beach Building Department m FROM: Captain Bob Ratliff SUBJECT: Plan Review for Poe's Tavern 363 Atlantic Blvd. The following discrepancies are noted on the plans as submitted: 1. Comply with FAC 69A- 60.0081 Notice Required for Structures With Light -frame Truss -type Construction. TT `A'''keveeD aiyT z .. 5Areer nevi 2. NFPA 1- 11.1.7.1* Means shall be provided for the fire department to disconnect the electrical service to a building, structure, or facility when the electrical installation is covered under the scope of NFPA 70. /veN glgovTT P AraW _ dhcr-- f 11.1.7.2 The disconnecting means shall be maintained accessible to the fire . department. /1/ S , ,Vr we ' PTIPN — S f er 4P' 11.1.7.3 Identification of Disconnecting Means. •— 74), 1 ,04.0-a - • SF/f T"A9oo 11.1.7.3.1 Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose is evident. /p P aa / " 11.1.7.3.2 The marking shall be of sufficient durability to withstand the environment involved. D "mom," Slim ?DO 3. NFPA 101 - 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapter 11 through Chapter 42 ... Provide Emergency Lighting in required areas. & wK ? fr• 5 5,ya-7- ,4 / 4. NFPA 101 - 12.2.2.2.3 Any door in a required means of egress from an area having an occupant load of 100 or more persons shall be permitted to be provided with a latch or lock only if the latch or lock is panic hardware or fire exit hardware complying with 7.2.1.7. Verify Panic Hardware. /3 forAive,,y0F 5 ' /N /{ee f rit0e'7 . FILE COPY Whore Florida Begins. 214 N. Hogan Street I Jacksonville, FL 32202 -4128 I Phone: 904 - 255 -8320 I Fax: 904 - 255 -8559 I bratliff @coj.net r CITY s , OF ATLANTIC BEACH ' NA > ' )1 800 SEMINOLE ROAD ,17.; ;: , °; �' ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002019 Date 5/19/11 Property Address 363 ATLANTIC BLVD UNIT 01 Application type description COMMERCIAL INTERIOR BUILD -OUT Property Zoning TO BE UPDATED Application valuation . 250000 Application desc INTERIOR REMODEL Owner Contractor SHOPPES OF NORSHORE LLC URBAN PARTNERS CONSTRUCTION P.O. BOX 330108 4320 PABLO PROF CT STE 103 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32224 (904) 219 -7579 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type MERCANTILE Permit PLUMBING PERMIT Additional desc . Sub Contractor . A TO Z CONTRACTING AND PLUMB Permit Fee . . . 111.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/15/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS FLORIDA FIRE PREVENTION CODE NATIONAL ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE PLBG DCA SURCHARGE 2.00 STATE PLBG DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 111.00 111.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 115.00 115.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 3 (03 44- l Qn'f t c Al V1> PERMIT # &ui tdrrtc — Il 00000iq. NEW OR REPLACEMENT INSTALLATION: Project Value $ TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank & Pit Clothes Washer Shower Dishwasher i Shower Pan Drinking Fountain Slop Sink Floor Drain i Three Compartment Sink Floor Sink :2 Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures 9 Water Treating System RE -PIPE: TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank & Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor (Trap) gallons (Requires 3 sets of plans) ❑ Lawn Sprinkler System - Number of Heads ❑ Well * * ** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection. ** p45ther h S i A,KS tlq ►4clti ?� 2 . Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or Local law regulation construction or the performance of construction. Property Owners Name Phone Number • Plumbing Company ,i, _ *u l . i I . c Office Phone3g0 -OgO7 Fax 7 83/2$ Co. Address: L[O(..a J--(it 1 L7' PO( City orKsoo()II (1 State L C Zip, 3 222 License Holder (Print): J v tL4 �ZS State Certification/Registration #aC Notarized Signature of License Holder ' • ,• ; ': ",, SEAN HARKENREADER ;worn and subscribed before me this • da N1,14 y 20 1( 9.° 's • Commission # DD 969508 - My Commission Expires March 09, 2014 Signature of Notary Public .,, ,+ ? !.rlry % CITY OF ATLANTIC BEACH A 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 mo o. INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002019 Date 5/19/11 Property Address 363 ATLANTIC BLVD UNIT 01 Application type description COMMERCIAL INTERIOR BUILD -OUT Property Zoning . . . . . . TO BE UPDATED Application valuation . . 250000 Application desc INTERIOR REMODEL Owner Contractor SHOPPES OF NORSHORE LLC URBAN PARTNERS CONSTRUCTION P.O. BOX 330108 4320 PABLO PROF CT STE 103 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32224 (904) 219 -7579 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type MERCANTILE Permit ELECTRICAL PERMIT Additional desc . REPAIR RELOCATE AND REMODEL Sub Contractor . LIMBAUGH ELECTRICAL CONTRAC Permit Fee . . . 90.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/15/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS FLORIDA FIRE PREVENTION CODE NATIONAL ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE ELEC DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 90.00 90.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 94.00 94.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 a-17 — 5S ) JOB ADDRESS: • (j r l+ 1(',.- l'r_' (vci . - -- PERMIT # //" Z • JEA INFORMATION REQUIRED ON ALL PERMITS 64 AMPS Z ' . PHASE VALUE OF WORK $ /1/ SO ) NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole :Residential (Main) Service 00 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Meters ❑ Commercial (Main) Service 00 -100 amps ❑ 101- 150amps 0151- 200amps ❑ amps OCT Service amps Conductor Type Size ❑ Multi- Family (Main) Service 0 0 -100 amps ❑ 101- 150amps ❑ 151- 200amps ❑ amps # of Unit Meters OTemporary Pole 0 amps SERVICE UPGRADE ❑ amps 0 CT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.) ❑ 100 amps 0150amps 0200amps 0 amps OCT Service amps ADDITIONS, REMODEL& REPAIRS, BUILD -OUTS, ACCESSORY STRUCTURES, ETC. Outlets/Switches: / 2 0- 30amps 31- 100amps 101- 200amps Appliances: 0- 30amps 31- 100amps 101- 200amps A/C Circuits: 0- 60amps 61- 100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: �� OTHER ELECTRICAL PROJECTS :Swimming Pool 0 Sign ❑Smoke Detectors Qty DTransformers KVA :Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) Qty volts/amps 41, VALUE OF WORK $ REPAIRS/MISCELLANEOUS /NAG/ /12al 5'X C.t.c� j „ :Replace Burnt/Damaged Meter Can ❑ Safety Inspection 0 aP nel Change 00H to UG ether: fib(4 Z i/ 41,�/f ee ha" Q' / d /4/`1�J /247-1 , "!. g 4,G /4t. U i' y "..e., CP'i,5 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances goveming this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name retvefl Phone Number 9 3 ' • ' 7 7? Electrical Company! e r n trrit i 41 Elco ricca 1 rIIC. i (13TPLOifice Phone 24 (-- 1cr5 J1 Fax Co. Address: 4-2 Ls{ +' 1 9 e City At Lin{ iG� h State FI • Zip 322?3 License Holder (Pr1nt): t t i ✓t Ltok S (\ S tate Certification/Regist 3002296 Notarized Signature of License Holder � 0 ,. 1 . Sworn and su. .cribed Defy : this I"(" may of t _ 201 Signature of Notary Public _ . . A . _ _ e. `� / , , - .___ MAY -23 -2011 11:28 FROM: CLERK OF COURTS 904 270 1512 TO :92475845 P :1/1 r NOTICE OF COMMENCEMENT Permit No. i( OOO? ?O i G Tax Folio No. 16 & - ocrT State of Florida, County of, Duval TH E UNDERSIGNED hereby give notice that the hnprovetnent will be made to certain real property in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commenactnent. \ t. Description of property (legal description of , • . and:'address if available): `` 2. General Description of im . + ements: ta,t a a, ,3""i z a ," - 'l//e770 .v,.r! 0/M6 / Un-/ Al& iri9"17/yr • ' r - • 1 Own In ormation: `'�' �•r'"y a) Name and' Address: w .: `., +o ' . __ 4 L ___ - Cie c. '. 1 -,~4- ti, b) Interest in property: - t81'7 ga- . t d34i ) „tax $ 32 c) Name and address of simple titleholder (if other than owner): 4. Contractor Information: a) Name and Address: L P Cd iiL� d C. . #_. n . t., s L; ok `C#,. IsS3. b) Phone Number: 404-4/o - az2t.s s.�u s pa -act b ill 5, surety information: a) Name and • Address: b) Phone Number: c) Amount of Bond: S 6. Lender. Information: a) Name and Address: _. N / b) Phone Number: 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by 713.13 (I)(a) 7, Florida Statutes: a) Name and Address: h) Phone Number's of Designated Person:_ 8. In addition to himself/hvrself,'Owner designates of _ to reeerve a copy of the Lienor's Notice as provided in Secion 713.13 WO), Florida Statutes. a) Name and Address: — _ b) Pbcntc Number of person or entity designated by o vner: 9 Expiration • date of Notice of Commencement (The expiration date is one (1) year from the date of Reconfirm unless a ditTerent date is specified: _ WARNING TO OWNER: ANY PAYMENTS MADE 13Y THE OWNER Ai THE EXPIRATION OF THE NOTICE OP COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART 1, SECTION 2,23 FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OP COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST r•NSPCCTION: IP YOU INTEND TO OBTAIN FINANC/Nt3, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR. NOTICE OF COMMENCEMENT, The foregoing acknowledged before 2 1f . ; ,.2,,,, : „.� , ` ga $instnrmentwnsack oXCrnethi 1 � day . (} ...,�t• i,,, • R r F 4 .�.• , . . R Notary Public MARY PtJB�L S ATE OF' /PJ , - , • " ~ ' - yr` • Kathleen Ma Pri Nam JG L1r.;f",r l E �. ► 1 !', -N' S a �� 4 '' !'" t `•'` d '; �e d Massachusetts .; ,:,.e ," 1-r" ...'"4;;•:,,0 r;` * ' h � % ‘ '�ttetirottyraelih 26 , 2 8 snap all I Cstovt , ✓ , � "T ' ip :,; rIrni$1001. on Jan , - ,I'p n y iS .' w . , -- $ 0 7 . -A, i = . . .. - - ' 0 1•dentifrcatioon ape; . _ .- ;, , 4 0' % ;.--2'.... . ' °' t Verifcatiorz pursuant to Section 92.525, Florida Statutes. Under penalties of perjury. I declare that 1 have tid,dtlii'= A�" foregoing and that tlrc facts stated in it are true to the best ofmy knowledge and belief: fo /,') 0.,,c Tr 20 i OR BK . 15806 Page T129 ' Signe orProp�t Number Pages: 1 Recorded 05/23,2011 8111:38 AM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 Revised TWiI2p$ •---- 11 • NEW "found object infill", 4" sphere max. size gap 4 .) &) ..1 fi NEW wood paltform riser - E E 0 ...- = // //jvf / *\ / \ CI*1°.6:;. 8" th. reinforced CIP concrete wall , \ / ,/ >/// / / \ : - 4l a:,44 w/ #5's at 12" o.c. vert. and horiz. te drill and epoxy into existing slab. ‘/ \7' / \ \ ' s ,.4.,,x..-4- . NEW stained concrete finish floor cu °PP* cro \ ,.. \.\// 21) ''' "''''''''''''''''°°''''''''''''''''''''"''''''' ' - / ` ex on °CN "C:J.04 . 9,,o-q•cioo.c / ,/ . lq0:10 ZW:e0:',30:*:::p.M0.Wp.V`:p.V.-1:0:0,9;V:icx.*ZigSD=.0.0.t, 1°„()Xer.:c6VS:ip,VS,D.°0:`')( s / / -Vol' It •194477: # 441 gi; V R e254 6pWAVA4t64 4 .53 4 4;e:9406i4::: . 441 4° 241P:44: 4 g4Fl4 \ .".. .°„. : a .6 ., / V / ..' / 1r / / ■ / / \ / / \ ///‘• \ ' ° \ ,''' /// //'>.)/- / 2 />// \ VA ,!/' \ ' / -//‘ / /, / / N -' < N / .,/ / ‘‘ K //` \ \ \ ' \ -, / \ \\ 2- \\ \/\ / / ''/ / ' 4 /‘ \ \K \\/ ‘ './ ' \ ' . / , i ./:// ' / //\ / 4:" ///// /// / /// //:' / 7'-0" NEW 6" concrete slab with 6" grid welded wire mesh reinforcing, tied slab to concrete wall using bent #5 rebar @ 12" o.c. A A.41:4■04,4,, -- EXISTING compacted hardfill 1 if 1 ' - '' -(e. OF p 1 it • ..... 4° ,9 IT. EXISTING concrete slab - . a V -* . ,.. , .ft _ -_,......t.R.: • x ■4 .% / . 0 . . iw 0 1R . . 4 : ' FILE co ..., `,4, 0 ''.. 1 . ■ . . — * ■ ... , 4,.. « ............, a tljoa„ , E D A ...fel #0,0 4winowiel s TITLE: WALL SECTION @ CIP WALL 1108 4 POE'S TAVERN h eva n ------"-----,•--- ---.--- , Altantic Beach, FL MED FOR CODE COMPLIANCE f May 20, 2011 566 kr or= CITY OF ATLANTIC BEACH 1 SK-001 ioertdoerfer Ipl 116.1 726 0002 SEE PERMITS FOR ADDITIONAL NI On 726 0004 REQUIREMENTS AND CONDITIONS. Irchitects t ....,.....“...k.die.d..... REVIEWED BY: - . ` CITY OF ATLANTIC BEACH } 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Z ost.19 Application Number 11- 00002019 Date 8 Property Address 363 ATLANTIC BLVD UNIT 01 /04/11 Application type description COMMERCIAL INTERIOR BUILD -OUT Property Zoning TO BE UPDATED Application valuation . . . 250000 Application desc INTERIOR REMODEL Owner Contractor SHOPPES OF NORSHORE LLC URBAN PARTNERS CONSTRUCTION P.O. BOX 330108 4320 PABLO PROF CT STE 103 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32224 (904) 219 -7579 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type MERCANTILE Permit MECHANICAL HVAC PERMIT Additional desc . Sub Contractor . FLORIDA HOME DBA ARS Permit Fee . . . 115.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date . . 1/31/12 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS FLORIDA FIRE PREVENTION CODE NATIONAL ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 115.00 115.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 119.00 119.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 6> AT L e, n L 6 1- 'V J /l ' �D PERMIT ir# 1_1-1-3-- PROJECT VALUE $ 11-N 1 0'6' ___________________ -( NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit -- Duct Systems: Total CFM Seer Rating REPLACEMENT AIR CONDITIONING & HEATING SYSTEM REQUIRED INSTALLATTIOON N IRED Air Conditioning: Unit Quantity 1 Tons Per Unit S 1 on ARI # �� UIR 0 Heat: Unit Quantity BTU's Per Unit REQUIRED Duct Systems: Total CFM Seer Rating A 5 d REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity Fire Standpipe (Requires 3 sets of plans) Underground Fire Main Quantity y (Requires 3 sets of plans) Fire Hose Cabinets Value (Requires 3 sets of plans) C re HoseiHoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING Elevators /Escalators Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces # Water Heaters Refrigerator Condenser BTU's Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Po c s Tc r V r r n Phone Number Mechanical Company Fl or `, 01 c,, k-i o yn z 10,13 , A, A, R r), Office Phone-n-y oo Fax111 - S el Co. Address: L-0. 11 - cr' Son 4,-1— City - 5c c R s on v 1 iz StateF 1 Zip - �"l,Cl License Holder (Print): p >~ S �� State Certification/Registration # C Yh C S), ` 9 r13 ■ Notarized Signature of License Holder ` 21 Pµ7 P�9' - CAROLYN TURNER worn and subscribed before day of p . C`` 20 J1 O P ` ;; :1; : , MY COMMISSION # EE061381S. ignature Of Notary Publi • y ow; ov,e , EXPIRES May 16, 2015 /r / /�j /f�/ 398 -0153 FloridallotaryService.com VI t l.�' l (iL ' tQll "s 11 15 1 11 CERTIFIED TM ww w.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3784260 Date: 8/3/2011 Product: Split System: Heat Pump with Remote Outdoor Unit -Air- Source Outdoor Unit Model Number: GSZ130603A* Indoor Unit Model Number: AEPF426016C * +TXV Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFA Rated as follows in accordance with AHRI Standard 21 0/240 -2008 for Unitary Air- Conditionin TURING CO., LP. Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, party testing: g and Air- Source independent, third Cooling Capacity (Btuh): 57000 EER Rating (Cooling): 11.20 SEER Rating (Cooling): 13.50 Heating Capacity(Btuh) @ 47 F 58000 Region IV HSPF Rating (Heating): 8.60 Heating Capacity(Btuh) @ 17 F: 36000 *Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory,org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference u The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, P rposes, CERTIFICATE VERIFICATION personal and confidential reference. The information for the model cited ontlt' certificate can be verified at www.ahridirectory.org, ` Y �, click the "Verify ertificate was issued, whlchs listed above, No., d the Certificate which is listed below. on .■ � ' Air - Conditioning, Heating, and Refrigeration Institute ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129568599706495940