Loading...
Permit Repairs 2109 Beach 2011 .,..,,,,\J‘J,...,, . `� CITY OF ATLANTIC BEACH .;--' oiri ; , 800 SEMINOLE ROAD J : ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002281 Date 7/01/11 Property Address 2109 BEACH AVE Application type description RESIDENTIAL OTHER Property Zoning TO BE UPDATED Application valuation . . . 100000 Application desc REMOVE STUCCO REPAIR BEAM AND FRAM Owner Contractor BLOCKER SHAYCORE ENTERPRISES INC P.O.BOX 330249 10169 GENI HILL CIR ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 Permit RESIDENTIAL ALT /OTHER Additional desc . Permit Fee . . . 480.00 Plan Check Fee . . 240.00 Issue Date . . . Valuation . . . . 100000 Expiration Date . 12/28/11 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Other Fees STATE DCA SURCHARGE 7.20 STATE DBPR SURCHARGE 7.20 Fee summary Charged Paid Credited Due Permit Fee Total 480.00 480.00 .00 .00 Plan Check Total 240.00 240.00 .00 .00 Other Fee Total 14.40 14.40 .00 .00 Grand Total 734.40 734.40 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION . CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247 -5826 Fax (904) 247 -5845 Job Address: „( Oq P e,c,8 1 . At)e tai - (c , ,`e , i F( 3 . 2 ; 3-3 Permit Number: a `v Legal Description 6L" I, ,,, W, ` t. 1 ,,,t (, ,c Parcel # 80 (:x 93 09 - - //- 6 I door Ar of Sq.Ft. Sq.Ft ' Valuation of Work $ (ae Proposed Work heated /cooled hi-/ 79 non- heated /cooled 9755 Class of Work (circle one): New Addition Alteration Repair Move Demolition pool /spa window /door Use of existing /proposed structure(s) (circle one): Commercial e�sidenti�al If an existing structure, is a fire sprinkler system installed? (Circle one): es o N /A Florida Product Approval # < g . vo+ 4 - I^ A•, }�, For multiple products use product approval form Describe in detail the type of work to be performed: e. e,Je. ,Il 4-1- „ccr: r, re.. 4- 9.( .ig o .. ckr,A rr_eIc II€_ Property Owner Information: Name: G C Q(cctc.' -- Address: 2,1C ei jl re, (A -, ( 4 u e- City A f ) , - � _ . r a eh . State pi Zip 3u33 Phone (' Gc <{) r ' 23 Y , 4 � ,, , '' , -- - ... ,� .. E -Mail or Fax # (Optional) a Contractor Information: FILE C P ¥ i Company Name: .5 Cri re. h,rrke r , , 63s I, tt)c.. Qualifying Agent: ► , .. . _1 V ` i Address: + - 3O �clSl ('�4 *. C{ City. er: tk';r :(le. 'Sratewq■ver-, „ „$ y ,:eili Office Phone(104-) 44/ - 7/5'3 Job Site / Contact Number troy) .2,V7 13`5._3 Fax # (fr«1 J 952 _ yyta State Certification/Registration # ' t c. i Z _ Architect Name & Phone # _ 1 ; BO !M . A . • . . . Engineer's Name & Phone # 0, . ' _ _ . o S9 S ?r 1 _ ” ' • �lIJ ►% Fee Simple Title Holder Name and A. dress .-, 1 _ _ V ' • An TIC i • Bonding Company Name and Address _ FOR ADDITION Mortgage Lender Name and Address — 1 . 0 • 'II' ' ' '�` b CONDITIONS. 1 21 E _I EV.IE Appl ication is hereby made to obtain a permit to do the work and installations as ind ii t n B w o . ' = ' - i ham c� •d dr' tJihe issuance of a permit and that all work will be performed to meet the standards of all laws regu . '• "' ', • . ' • • mz ec and void if work is not commenced within six (6) months, or if construction or work is suspended or abandoned for aperzod of six 6J nu . — work is commenced. 1 understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, F urnaces, Boilers, Heaters, Tanks and Air Conditioners, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this a plication and know the same to be true and correct. All provisions of : and ordinances : overning this type of work will be compli- with whether specified herein or not. The granting of a permit does not presume to • e a thority to v'. ate : r cancel the provisions of any other fed! 1, state, or local law regulating construction or the performance of construction. 1 Signature of Ow a c t , _, • Signature of Contractor II Print Name ,45 C 2 -- Print Name ( ` Yh ot,)K Sworn s4 at d crib:. before me Swo and subsc 'bed before me thisc2fity of ' .�I" . iA�� / 201 / th -+' O : . y o � _ ,' t MI- Araimplar , "..doinwiffits-Tor. : , ., . ... Leire, .,,,.„ 1 ,_ . _ , ___,......, Notary 'us -! s ,,'. MY COMMISSION # DD 957760 : .'u.lie . ,: , +; ��S�y p DD957760 EXPIRES: February 14, 2014 l - , 4 :onded Thu Notary public Underwriters ' , 1 ' ^ p t`, ` 6,,,' it ■ t a ia ta rs2 1 .10 rluh't� C y11�f ; City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road // ,. Atlantic Beach, Florida 32233 -5445 / Phone (904) 247 -5826 • Fax (904) 247-5845 V3)1/4 ' E -mail: building- dept @coab.us Date routed: City web -site: http: //www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: cPlo 9 , 4i4 !/7 X V ent review required Ye No _ C Buildsng V Applicant: 7� t4t I c---4 /ce Manning & Zoning Tree Administrator Project: 4 `/ / di Public Works Public Utilities Public Safety Fire Services ReNi6V fe $ `11 14 „� . } lsr2 r � �fi9t r -' • :�.� . e .,.,.,, ,, a� alai t � #tiC V' s*ssfdr Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: Approved. ["Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING / Reviewed by: / Date: 6 TREE ADMIN. Second Review: ❑Approved as revised. ❑ enied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. nDenied. Comments: Reviewed by: Date: Revised 07/27/10 Division 09 21 23 Portland Cement PI,stcr N TITAN' - -----2.... 4ft. . ER 11„ .A., STUCCO CEMENT ITAN AMERICA® Stucco Cement is specifically designed for the plastering trade. This product, the result of extensive testing and controlled production, has characteristics desired by the stucco applicator. Titan America® Stucco Cement, with proper proportions of sand and clean, potable water provides a smooth, �'� " r * :1 wo mix that retains good ' r4 , � consistency and develops a strong, . .. " bond. While Titan America® Stucco k 4 : { i Cement can inhibit moisture penetration, it is not waterproof : and is not to be considered a moisture barrier for design or construction purposes. %= IN ,, { :4 j Extended water retention f'- y , ► Superb workability ti Reliable performance . ` L Quality packaging � ' ) I d =gm ' , M 1 STUCCO CEMENT. A ��.� "" ..E � _: 4 nowt a �'4,, • .,,� ,.. � TITAN :-.e.:. fi _. RECOMMENDED USES - _ 1 ;, - _ ,4 i . Titan America° Stucco Cement is specifically designed for interior and exterior applications `� , ,, >y of Portland Cement based plasters. It is common to see this product applied over wire '�'- ; } : "° . " lath, concrete unit masonry and cast -in -place concrete. Additional additives may be Ai), ' ' , t- „' i ~''" ,-' required to assist in the bonding of the Stucco to certain substrates such as cast -in -place or pre -cast concrete. ACCESSORY PRODUCTS SPECIFICATIONS AND QUALITIES The water and aggregate used in the mixing process should be free of any substance that could adversely Titan America® Stucco Cement is manufactured by inter - grinding Portland Cement Clinker affect the hardened masonry or any metal accessories (meeting ASTM C -150), Gypsum and Umerock. Water repellent and air - entraining admix- used in the system. tures are added during the manufacturing process to assist with workability and board life. Titan America® Stucco Cement meets or exceeds the requirements of ASTM C -91. APPLICATION Titan America® Stucco Cement when mixed with masonry sand (ASTM C -144) and tested Estimated coverage per bag of material in square feet. according to ASTM C -270 will produce a mortar that complies with those requirements. Parts" Titan America® Stucco Cement, when mixed in accordance with ASTM C -1328, Pan es Thickness /Grueso will produce stucco cement that meets or exceeds the requirements of that Standard. INSTRUCTIONS 3/8" 3 /8 5/8 7 /8° Than America® Stucco Cement 2 :1 112 84 67 48 PROPORTIONAL MIXING GUIDELINES 3 :1 128 96 77 55 Plaster Coats Titan America" Sand /Arena ® 144 108 87 62 Masonry Parts /Partes Shovels /Part 4:1 160 120 96 69 70 lb. bags C' cinenl:`1nd PalriS ['a,ir Cun, : 1f No allowance for waste, aggregate size or field Scratch (Capa Inicial) 1 Bag 2 : 4 15 -24 conditions. Actual coverage will vary. Brown (Segunda Capa) 1 Bag 1111M11 18 -24 *Sand to Cement ratio. CAUTION Scratch (Capa Inicial) 1 Bag 2 : 3 12 -24 Causes skin irritation, injurious to eyes. • No allowance for waste, aggregate size or field conditions. Contains Portland Cement. Freshly mixed • One bag of Titan America® Stucco Cement is approximately one cubic foot by volume. cement, mortar, concrete or grout may • Approximately six #2 shovels of damp, loose sand equals one cubic foot by volume. cause skin injury. Avoid contact with skin CEMENT PREPARATION where possible and wash exposed skin areas promptly with water. If any cement Titan America ® Stucco Cement will not perform as designed if the mixing instructions are or cement mixtures get into the eyes, rinse not followed correctly. It is important to ensure that the product does not dry out prema- immediately and repeatedly with water for turety; this condition can affect the overall strength and durability of the finished product. 15 minutes and get prompt medical attention. The cement should be mixed only with clean sand and potable water unless prior sampling shows potential job materials will produce the desired mortar. Mix in a mechanical mixer as follows: I(EEP OUT OF THE 1) Add approximately 2/3 of the potable water required. REACH OF CHILDREN 2) Add 1/2 of the sand required (ASTM C -144 approved). 3) Add Titan America® Stucco Cement. 4) Add the remainder of the sand (ASTM C-144 approved). Titan Florida , , �, • 5) Add enough potable water to bring mortar to desired consistency. 11000 NW 121st Way i 6) Allow mortar to mix 5 minutes after the introduction of the last ingredient. Medley, FL 33178 •`'. Short mixing or overloading with sand can produce a lower mortar quality. WALL PREPARATION For additional information or to obtain All surfaces to be plastered must be clean of contaminants and /or any debris, including Material Safety Data Sheets, please visit excess uncured mortar from block masonry that may affect the Stucco Cement from www.titanamerica.com or call Customer achieving adequate bond. It is recommended, prior to any application, to determine Service at (800) 226-2057. whether there is a need for a bonding agent to assist in the attachment of the Stucco Cement. Concrete Block applications should be uniformly wet (fogged) just prior to application of the first and each succeeding plaster coat. To obtain the best results, ©2006 Titan Florida TAR 2138.04 9/06 some moisture should be maintained in the stucco (by fogging if necessary) for the first few days after application. , or ,t PermaLath 1000 9) \ fr Product Bulletin Description Open weave, three- dimensional, self- furred, nominal 1/4" thick glass fiber reinforcing lath designed for use with StuccoBase by BASF Construction Chemicals, LLC - Wail Systems (herein after referred to as "BASF Wall Systems ") or with field mix exterior cement plaster conforming to ASTM C926 at a minimum thickness of 3/4" in "scratch and brown" applications. Listed in ICC -ESR -2429. U.S. Patent 7,625,827. Uses A component of a 1 /2 "to 3/4" thick cementitious exterior wall coating application of exterior Portland cement plaster (traditional stucco) application that provides keying and continuous reinforcement for stucco used on vertical wall applications with solid backing. May also be used as a mortar base for light- weight veneer facing products such as precast stone veneer. Not for use on soffits or open framing. Note: PermaLath 1000 may also be used with StuccoBase by BASF Wall Systems or other cementitious exterior wall coatings manufactured in accordance with ICC-ES AC-11 at a thickness of 1/2". Technical Support Consult our Technical Services Department for specific recomnlendations concerning all other applications. Consult the PermaLath web site, www.permalath.basf.com for additional information and for updated literature. Technical Data Weave Leno Weight 294 g/m (8.8 oz/yard) ±5% Min, Tensile Strength Warp 59 kg /cm (330 lb/inch) Weft i 57.9 kg /cm (324 lb /inch) Color ' Gray Packaging 39" x 150 lineal feet roll in poly bag, 14 kg (31 lbs.) per roll. Features & Features Benefits Bereft Non metallic Will not rust Pliable, with no sharp edges Easier and safer to handle and cut Non- directional Can be applied vertically or horizontally Wide rolls F overlaps required to give better coverage Three- dimensional profile S - kiting, excellent mechanical key using traditional fastening procedures Alkali resistant Long -term durability and performance Packaged in light- weight rolls Application time /labor savings r BASF The Chemical Company BASF Wail Systems 1 PermaLath Application General: Apply PERMALATH 1000 in accordance with Specifications and the following: A. Acceptable substrates include cement board (ASTM C1325 Type A Exterior), gypsum sheathing (ASTM C79/C1396 or C1177), exposure 1 or exterior grade plywood, exposure 1 OSB, poured concrete or unit masonry. Apply /install substrate per the manufacturer's instructions and applicable building codes. Not for use over open framing. B. Secondary moisture protection barrier (Not required on unit masonry /non - insulated concrete substrates surfaces to receive the cement plaster stucco). 1. Over wood or metal framing with sheathing, a weather resistive barrier must be installed. When installed over wood based sheathing (plywood or OSB1, two layers of grade "D" building paper are required by IBC prior to installation of PERMALATH 1000. Other acceptable secondary moisture protection barriers include polymeric weather resistive barriers such as Tyvek® Stuccowrap® and acceptable equals that comply with and are recognized by local building codes. Trowel /roller applied weather barriers can be used provided a subsequent layer of a polymeric weather resistive barrier such as Tyvek Stuccowrap or grade "D" building paper is applied over the trowel /roller applied weather barrier. 2. Install the secondary moisture protection barrier over the substrate according to manufacturer's specifications and applicable building code requirements. 3. The secondary moisture protection barrier shall be free of any damage such as holes or breaks, and must be applied to all surfaces to receive the cement plaster stucco. 4. Wrap the secondary moisture protection barrier into rough openings (doors, windows, etc.) to increase the level of protection to the building frame and interior. 5. Coordinate work with other trades to assure proper sequencing, detailing and installation of materials. C. Trim 1. Install trim accessories per drawings and specification. D. PERMALATH 1000 1. Apply PERMALATH ® 1000 over substrate with minimum 3" overlap at vertical and horizontal edges and overlap on flange of trim accessories. PERMALATH ® 1000 can be applied horizontally or vertically and should be applied such that it is flat and free of ripples, wrinkles, etc. 2. Fasteners: ULP -302 (1 3/4 ") or Lath Plate (1 1/4 ") Mechanical Fastening Systems by Wind -Lock Corp. a. Masonry: masonry type [M] expansion fastener with ULP 302 diameter washer; or Lath Plate 25 mm (1") minimum penetration into masonry. Fastener spacing 6" o.c. vertically and 16" o.c. horizontally. b. Light Gauge Steel Framing/Furring (20 Gauge): light metal type [LM] bugle head screws with ULP 302 (1 3/4 ") diameter washer or Lath Plate 16 mm (5/8 ") minimum penetration into framing 6" o.c. vertically and 16" o.c. horizontally c. Heavy Gauge Steel Framing (18 to 12 Gauge maximum): metal type [S] bugle head screws with ULP 302 (1 3/4 ") diameter washer or Lath Plate or 32 mm (1 1/4 ") long x 2.5 mm (1/8 ") diameter VersaPin Gripshank®fasteners by Aerosmith Fastening Systems with Lath Plates; 16 mm (5/8 ") minimum penetration to framing 6" o.c. vertically and 16" o.c. horizontally. d. Wood framing: wood type [W] bugle head screws with ULP 302 (1 3/4 ") diameter washer or Lath Plate; 16 mm (5/8 ") minimum penetration into framing or minimum 16 gauge wire staples with minimum 3/4" crown and minimum 3/4" penetration into framing, 6" o.c. vertically and 16" o.c. horizontally. Notes: Supplemental fasteners, into the framing or sheathing, can be used to secure the PERMALATH 1000 prior to application of cement plaster stucco. Fastening systems/tools for staples are available through Senco (www.senco.com) and other manufacturers. 3. Apply cement plaster stucco within 60 days of PERMALATH 1000 application. E. Exterior Cement Plaster Stucco (ASTM C926) or Cementitious Exterior Wall Coating (ICC -ES AC -11) 1. Install per Specifications and Details F. Veneer facing mortar 1. Install per Specifications, Details and veneer facing manufacturer's specifications. PRODUCT BULLETIN Shipping, A. Protect PERMALATH during transportation and installation to avoid physical Handling & damage. B. Store PERMALATH ® 1000 in an upright position in a cool, dry place protected from exposure to moisture. Protect from extreme heat and direct sunlight. Limitations A. Not for use on soffits or open framing. B. Minimum thickness of 1/2" when STUCCOBASE or other cementitious exterior wall coating is installed in accordance with ICC- ES- AC -11. C. Maximum allowable weight of veneer facing products is 15 lbs. per square foot. Warranty BASF Construction Chemicals, LLC, through its Wall Systems Division ("BASF Wall Systems "), warrants that this Product, if used and applied in accordance with BASF Wall System recommendations set forth, will be free from defects in material for a period of one (1) year from the date of original purchase. BASF Wall Systems will replace or, at BASF Wall Systems' election, refund the purchase price of any portion of this Product proved to be defective. Satisfactory results depend not only upon quality of the Product but also upon factors beyond our control. Except as expressly stated herein, BASF WALL SYSTEMS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, OF ANY KIND WHATSOEVER CONCERNING THE PRODUCT. BASF WALL SYSTEMS EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. BASF WALL SYSTEMS ALSO EXPRESSLY DISCLAIMS, AND WILL NOT BE RESPONSIBLE FOR, ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. BASF Wall Systems will have no liability if the problem with the Product or apparent defect is attributable to misuse, improper installation or application, alteration or mishandling of the Product. Any claim arising from an alleged Product defect must be received by BASF Wall Systems in writing within thirty (30) days of the date of discovery of the alleged defect or one (1) year from the date of original purchase, whichever is sooner. No claim will be processed or considered unless BASF Wall Systems receives written notice of such claim within the time limitations stated above. User is fully responsible for determining the suitability of the Products for the intended use and assumes all risks and liability in connection therewith. Any authorized change in printed recommendations concerning the use of this Product must bear the signature of the BASF Wall Systems Technical Service Manager. BASF Wall Systems 1 PermaLath ® 1000 Manufacturer Permalath" is manufactured exclusNely tor BASF Wall Systems by Saint - Gobain Technical Fabrics America,Inc. Disclaimer BASF Wall Systems is an operating unit of BASF Construction Chemicals, LLC.( hereinafter referred to as "BASF WaN Systems "), This information and all further technical advice are based on BASF Wall Systems' present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extant to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF WaN Systems disclaims any and all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR [APPOSE OR MERCHANTABILITY. wa WALL SYSTEMS SHALL NOT BE RESPONSIBLE FOR CONSE(k1ENTIAL, NID81ECT OR INCIDENTAL DAMAGES (8JCLUDtG LOSS OF PROFITS) OF ANY KIND. BASF Wall Systems reserves the right to make any changes according to technological progress a further developments. It is the customer's responsibility and obtgaton to carefully inspect and test any incoming goods. Performance of the products) described herein should be verified by testing and carried out only by quaffed experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL 32224 -2614 Phone 800 • 221 • 9255 Fax 904 • 996 • 6300 www.permalath. basf.com ©2010 BASF Construction Chemicals, LLC. Punted in U.S.A. 01/10 5t0 Product Bulletin Sto Essence DPR Finishes +4 F . t 0:5 0 80306 Sto Medium Sand Finish 80307 Sto Swirl Finish ���,,,JJJ I t 80310 Sto Fine Sand Finish i1* i e - . , • . . . E u ...., — Technical Data Sto Essence DPR Finishes are REPORT TEST METHOD TEST CRITERIA TEST RESULTS ready - mixed, acrylic -based exterior or interior textured Surface Burning ASTM E-84 < 25 Flame Spread 0 finishes used as decorative and < 450 Smoke Developed 5 protective wall coatings over Flexibility ASTM D-522 4" mandrel bend Pass prepared vertical concrete, m masonry and plaster substrates Water Vapor ASTM E -96 28 days 34 and in Sto Wall Claddings, Transmission Method B including StoTherm Essence (U.S. perms) NExTT'A, in StoQuik Silver Cement Board Stucco cladding, Accelerated ASTM 0 -154 2000 hours No deleterious effects @ and in Autoclaved Aerated Weathering 5000 hrs Concrete (MC) wall applications. Chalk Rating ASTM D-4214 5000 hours 8 (10 = best on scale 1 -10) Coverage Yellowness Index ASTM E- 313 5000 hours 0.58 (0 = no change; Sto Medium Sand Finish: 110 - 2 = barely discernable 130 ft (10.2 -12.1 m per pail. change) Sto Swirl Finish: 120 -140 ft 2 ) Freeze -thaw ASTM 2485 60 cycles No deleterious effects 90 Sto (11.1-13.0 Fi ne S e. rn and d per pail. Finish: 140-160 ft � Sto Fine ft Resistance cycles (13.0 -14.9 m per pail. Mildew Resistance ASTM D -3273 No growth @ 28 days No growth © 60 days Coverages may vary depending on application technique and Salt Spray ASTM B -117 300 hours No deleterious effects © surface conditions. Resistance 1000 hrs Wind Driven Rain Fed TT- C -555B 24 hour driving rain No water penetration Packaging Water Resistance ASTM D -2247 14 days No deleterious effects @ 42 5 gallon pail (19 L). days Abrasion Resistance ASTM D -968 528 qts. sand No cracking, checking or Shelf Life loss of film integrity © 528 qts, 12 months, if properly stored and sealed. Tensile Adhesion EIMA 101.03 No failure in the EIFS Pass (psi) adhesive, basecoat or finish; minimum 5 psi Storage Adhesion ASTM C -297 28 days > 80 to concrete Protect from extreme heat [90°F (32°C)1, freezing, direct sunlight. Fire Resistance ASTM E -119 No effect on fire Pass resistance rating of existing rated assembly VOC (g/L) This product complies with US EPA (40 CFR 59) and South Coast AQMD (Rule 1113) VOC emission standards for architectural coatings. VOC less than 50 g /L. Features Benefits 1 Vapor Permeable Allows substrate to breathe naturally; resists blisters caused by trapped vapor 2 Moisture Resistant Repels water; resists wind driven rain 3 Water -based Safe, non - toxic; cleans up with water 4 Dirt pick -up resistant Resists mildew and algae growth; low maintenance 5 Low VOC Meets South Coast Air Quality Management District Requirements Page 1 of 2 Product Bulletin sit) Sto Essence DPR Finishes Surface Preparation Health And Safety Concrete and masonry surfaces: Surfaces must inhibiting materials. be clean, dry, and free of frost, damage, and all Gypsum wallboard surfaces: Wallboard must be Health Precautions bond- inhibiting materials, including dirt, taped and fasteners w an is water aced. As efflorescence, form oil and other foreign matter. Refer to ASTM C -840 and gypsum um w jowt allboard compound. with th any chemical Loose or damaged material must be removed by manufacturer's literature. construction m handling. water blasting, sandblasting or mechanical wire Surface must be free of dust, dirt and other bond- Safety Precautions brushing and repaired. Avoid application over inhibiting materials. Surface must be primed with Use adequate ventilation. irregular surfaces. Resurface, patch or level appropriate Sto Primer. Safety goggles and surfaces to required tolerance and smoothness with Autoclaved Aerated Concrete (AAC): Base coat Protective gloves are appropriate Sto leveling materials. Refer to ASTM D- must be fully dry and smooth. Base coat surface recommended. Remove 4258 and ASTM D-4261 for complete details on must be free of all bond- inhibiting materials. contaminated clothing methods of preparing cementitious substrates for immediately. coatings. Sto recommends priming cementitious First Aid StoTherm Exterior Insulation and Finish substrates using the appropriate Sto primer SKIN CONTACT: w ean Cho Systems (EIFS): Surface must be free of all bond- prior to application of finish. raugnry with soap and water. Mixing EYE CONTACT: Flush immediately with water for 10 Mix with a clean, rust -free electric drill and paddle to Limit addition of water to amount needed to achieve phhysiciann�� and contact a a uniform consistency. A small amount of dean the finish texture. RESPIRATORY water may be added to aid workability PROBLEMS: Remove Application affected person to fresh air Immediately and contact a to sound and clean, dry, properly physician. Apply only ry, pro rl cementltious substrates. Apply coating in a HYGIENE: Wash hands prepared, frost -free surfaces. continuous application, always working from a wet immediately after use. Wash Trowel: Apply Sto Essence Finishes with a clean edge or architectural break to eliminate cold joints. clothing betore re - use. stainless steel trowel to a rough thickness slightly Minor shade variations may occur from batch to more than the largest aggregate size. batch (refer to batch no. on pail). Avoid installing Cpills Use the trowel to scrape the material down to a separate batches side -by -side and avoid application absorbent h suitable uniform thickness no greater than the largest in direct sunlight. Avoid installing new finish co material such as cotton rags. aggregate size. Achieve final texture by floating with adjacent to weathered or aged finish. Sto Corp. will Disposal the appropriate trowel in a figure eight motion; not be responsible for shade or color variation from Dispose of In accordance stainless steel trowel for Sto Medium Sand and Sto batch to batch, variation caused by application or with local, state or federal Fine Sand (pebbled texture finish) and plastic float substrate deficiencies, or fading resulting from regulations. for Sto Swirl Finish (rifled texture). Once applied, the natural causes such as weather. See Tech Hotline Warning working time is up to 20 minutes depending upon Nos. 0694 -C, 0893 -EC and 1202 -CF for helpful tips KEEP CONTAINER material, ambient temperatures and surface on prevention of color problems. CLOSED WHEN NOT IN conditions. Protect installed product from rain, freezing, and USE. KEEP OUT OF THE Spray: Apply Sto Essence Finishes with a handheld continuous high humidity until completely dry. REACH OF CHILDREN. gravity -feed hopper -type sprayer, texture spray Curing/Drying NOT FOR INTERNAL pump machine, or other appropriate equipment such Sto Essence Finishes dry within 24 hours under CONSUMPTION. FOR as the StoSilo system or Sto's M -8 Spray Pump. normal conditions (70 °F (21 ° C), 50% RH). INDU the USE ONLY Apply an even coat to ensure full coverage of the Drying time varies with temperature/humidity and consult Data Sheet S the e or furthl r h eals surface. (Spray application is not recommended for surface conditions. information. health Sto Swirl Finish.) Clean Up and safety ination. IMPORTANT: ALWAYS check color for proper Clean tols and equipment with tools immediately LIMITED W s sus act to match. If color does not match, STOP -call your Sto after use. Dried material can only be removed w hir product is subject to a re written limited obtai ned • For best results always prime mechanically. which ich n Presentative can be obtained free L i n t i to ±ions of charge from Sto Corp. Refer to Sto Specifications • Use Sto Essence Finishes only when surface and • Sto Essence Finishes should not be used on more complete info ambient temperatures are above 40 °F (4 °C) and weather- exposed horizontal, below grade or and h a di n on proper o u below 100 °F (38 °C) during application and drying water immersed surfaces. end handling of this prodrict period. • For Exterior Insulation and Finish Systems • Sloped surfaces: Refer to Sto details. (EIFS), select finish colors with a Tightness value of 20 or greater. Sto Corp. S188-80308, Attention 3800 Camp Creek Parkway 80307, 80310 This product le intended for use by qualified professional contractors, not consumers, as a component of a larger coretrudion assembly Building 1400, Suite 120 Revision: 02 2 improperly, as specified by a qualified design professional, general contractor or builder. It should be 'Walled in accordance with those Atlanta, GA 30331 Date: Revision: 0 specifications and stn's instructions. Sto Corp. disclaims all, and assumes no, liability for on.s0e inspection, for as products apapplied rly, or by unqualified persona or entities, or as part of an improperly designed or constructed building, for the nonperformance of adecent building components or assemblies, or for other construction activities beyond Sto's control. Improper use of the product or Tel: 404-346-3666 use as part of an improperly designed or constructed larger assembly or building may result in serious damage to tale product and to the structure of the budding or Its components a• : _ ,f 1 .. . •. .. , > Toll Free: 1- 800 -221 -2397 5puc a ITEgwra EN w - IF Fn T AND 7 II � N A( ,npnANr0 f ry Fa Toll 346-3119 o : , . , a •s:.. f r\ �� E tTl�,., t ,. _ For the tulles, meet current \I re information on proper application clean- up,�mixing and other specifications and warranaea, cautions and disclaimers, please refer to the www.stocorp.com ' ""'r' SGS '''" SGS Sto Corp. webeoe, www stoca coin. Page 2 of 2