Loading...
BEACH AV 1852 t �I�rT�Nfyi - - • 12 I PG �in�r.,o flc-,tern -m tc-7 ►-( pes r- � same-* R GA$16 e.r 41vPt14w 9WAI {: >� m p&sr, �P G!1 MA'fGN ifHi,"i '� Pill ` I t i f � �pfZG lL P->14S5T_IANA x ji + ii Imo- O t'no Sc�uao _148 P,4-4 r=n1p� C P.) G REVISIONS BY UPLIFT CONNECTOR SCHEDULE STRUCTURAL NOTES: DESIGN IN ACCORDANCE WITH REQUIREMENTS OF THE 1997 STANDARD 1 ROW 8d COMMON WIRE NAILS ® 3" O.C. MEMBER SUPPORT SEMCO CONNECTOR BUILDING CODE AND WIND DESIGN PER SECTION 1606.2. 1. LIVE LOADS 1 pc SEMCO FAP18 COMMON RAFTER: HEADER BEAM (2)HCPLR UNIFORM LIVE LOADS WALL LEDGER (1)FAP18 ROOF 20 PSF 2. WIND LOAD BASIC 110 MPH WALL LEDGER EXISTING FRAMING 4 ROWS 16d COMMON WIRE IMPORTANCE FACTOR 1.00 '/2" CDX PLYWOOD NAILS ® 16" O.C. MEAN ROOF HEIGHT 15.0 FT ROOF SHEATHING FASTENED WITH ROOF PITCH 4/12 (18.4 DEGREES) 2"x8" SYP NO.2 12 8d COMMON WIRE NAILS @ 4" OC PORCH HEADER BEAM 4"x4" POST (2)RTPGA816 LEDGER w/ 4 ROWS 4 EDGE AND 6" OC FIELD. 3. ALLOWABLE UNIT STRESSES: _ 16d COMMON WIRE � 4x4 POST FOUNDATION (1)ABP44 NAILS M 16" O.C. 2"x8" SYP NO.2 RAFTERS ® 24" O.C. A) CONCRETE – DESIGN AS PER ACI 318 LATEST EDITION INTO EXISTING CONVENTIONAL ROOF FRAMING, SEE SLAB ON GRADE Vc = 3000 PSI WALL FRAMING. ROOF FRAMING PLAN CONVENTIONAL SHALLOW FOOTINGS f'c = 3000 PSI NOTES: ALL OTHER CONCRETE (U.N.O.) f'c = 3000 PSI 2pcs SEMCO HCPLR 1) CONNECTORS ARE SOUTHEASTERN METALS (SEMCO) OR EQUIVALENT. B) REINFORCING STEEL – ASTM A615 GRADE 60 U HURRICANE CLIPS PER UPLIFT 2) SEE DETAILS THIS SHEET FOR TYPICAL APPLICATIONS. z CONNECTOR SCHEDULE. 2 USE THE FOLLOWING FASTENERS FOR EACH CONNECTOR: — w C) WELDED WIRE FABRIC – ASTM A185 RTPGA816 16-10d '-'-' Q Ld z_ FAP18 10-1 Odx1'/2" D) CONCRETE MASONRY – DESIGN PER ACI 530 CURRENT EDITION = o � HCPLR 8-1 Odx1'/2" I._ w ?o z TOP PLATE EL ABP44 1/2" Ox 10" ANCHOR BOLT AND 12-16d COMPRESSIVE STRENGTH f m = 1500 PSI Q J z Q SEE ARCH PLANS _ 1 E) SOIL BEARING (DESIGN MAX.) 2500 PSF <0 J w F) ALL DIMENSION LUMBER HEADERS AND BEAMS SHALL BE SYP NO. 2 D o m " 2 cs SEMCO RTPGA816 STRAPS OR BETTER, WITH AN ALLOWABLE BENDING STRESS IN ACCORDANCE � w w DBL 2x8 SYP No.2 HEADER BEAM. FROM HEADER BEAM TO POST WITH NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION LJ En }- SPLICE TOGETHER w/ 3 ROWS 12d BY AMERICAN FOREST & PAPER ASSOCIATION. ALL 4"x4" POSTS = o Oz o COMMON WIRE NAILS ® 12" O.C. Q z o N SHALL BE PRESSURE TREATED SYP NO. 2 (UNLESS NOTED O J �0 4"x4" PRESSURE TREATED 0 SYP NO.2 POST EXAMPLE OF UNSUPPORTED (UNBLOCKED) OTHERWISE). Z o �. BOUNDARY OF ROOF PANEL EDGE. UNSUPPORTED PANEL EDGE IS 4. UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM CONCRETE COVER o 0 DECKING TYPICAL CONDITION UNLESS BLOCKING IS REQ'D FOR REINFORCING SHALL BE AS FOLLOWS: = U z BY SCHEDULE OR NOTES. FOOTINGS 399 U . . . SLAB ON GRADE CENTERED X w . . • 5. ALL REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAMS AND PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. ALL REINFORCING STEEL SHALL BE HELD 1/2" CDX PLYWOOD SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. 1c SEMCO ABP44POST ANCHOR P w/ '/2" x10" ANCHOR BOLT AND NAIL SPACING AT 6. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE AS FOLLOWS: 12-16d COMMON WIRE NAILS SUPPORTED EDGES, . . EXAMPLE OF PANEL MASONRY 48 BAR DIAMETERS /2" EXPANSION JOINT 4 CONCRETE SLAB ON GRADE w/ SEE NOTES OR SCHEDULE z EDGE w CONCRETE 40 BAR DIAMETERS MATERIAL WWF 6x6 W1.4xW1.4 OVER 6 MIL WHERE RBLOCKING REQUIRED BY 0 VAPOR BARRIER ON COMPACTED FILL. . • SCHEDULE OR NOTES 7. IF THE FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED OR M. • UNSTABLE SOIL, THE ENGINEER SHALL BE NOTIFIED. �j X x — X X X X X X X - X X X 8. ALL LOAD BEARING CMU PIERS SHALL BE COMPOSED OF ASTM C90 • =1 I IE:l 117 _ GRADE--I`i-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. Lli 1—III -� RAFTERS GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH Q U 111 I i I 1 11—'. 8"x8" THICKENED EDGE I I l CONCRETE GROUT.. W/ 1–#5 CONTINUOUS 1 1 9. PROVIDE ALL TEMPORARY BRACING, SHORING, GUYING OR OTHER = W Q MEANS TO SUPPORT STRUCTURAL ELEMENTS IN PLACE DURING U Q L 20"x10" MONOLITHIC CONCRETE NAILING TO INTERMEDIATE CONSTRUCTION. O FOOTING W/ 2–#5 CONTINUOUS 10 SUPPORT IS 6 OC MAX, UON 0 (f� -1 NAILING PATTERN FOR ROOF SHEATHING 10. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 0 W = SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING CL fy U DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES, ETC. WHICH ARE NOT Q 1 WALL SECTION , TYPICAL 3 DETAIL SHOWN ON STRUCTURAL DRAWINGS. Q m Z 2 S-1 SCALE: 3/4" 1'-0" SCALE: NTS w 11. THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE Fz S-1 = RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE V) CONTRACTOR, OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR j Q 4"x4" PRESSURE TREATED THE FAILURE OF ANY OF THEM TO CONSTRUCT THE WORK IN U SYP NO.2 POST ACCORDANCE WITH THE CONTRACT DOCUMENTS. 0 1 pc SEMCO ABP44POST ANCHOR U � w/ '/2"Ox10" ANCHOR BOLT AND 12-16d COMMON WIRE NAILS ry Q W BRICK PAVERS ON COMPACTED SAND BED 8"x8"x5.5" HIGH AS PER ARCHITECTURAL CONCRETE PIER PLANS d- 2'-8"x2'-8"x1'-4"d I af CONCRETE FOOTING Q W/ 3–#5 EACH WAY w Ll 1–#5 VERTICAL DOWEL W/ n 3" LEAR TYP STD 90' BEND 2'-8" x 2'-8" DRAWN PRB CHECKED CCK 2 ALTERNATE PIER FOUNDATION 04/23/01 S-1 SCALE: 3/4" = 1'-0" SCALE AS NOTED JOB NO. : E01-082 \Ca C .• �,�jF�C•.•'f'y SHEET •�� O V V .sem in 04 1-1 r�REO r��4 SHEET 1 OF 1