Permit Mech 1370 Ocean Blvd 2011 y ? , ./ \
4 ' CITY OF ATLANTIC BEACH
�
w 800 SEMINOLE ROAD
n ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247 -5814
Application Number 11- 00002427 Date 8/02/11
Property Address 1370 OCEAN BLVD
Application type description MECHANICAL HVAC ONLY
Property Zoning TO BE UPDATED
Application valuation . . . 0
Application desc
1 cu 1 ahu
Owner Contractor
VANCE, CHARLES INDOOR COMFORT
715 VALLEY FORGE RD. 1539 MONTANA AVENUE
JACKSONVILLE FL 32208 JACKSONVILLE FL 32207
(904) 396 -7771
Permit MECHANICAL HVAC PERMIT
Additional desc .
Permit Fee . . . 99.00 Plan Check Fee . . .00
Issue Date . . . Valuation . . . . 0
Expiration Date . 1/29/12
Other Fees STATE MECH DCA SURCHARGE 2.00
STATE MECH DBPR SURCHARGE 2.00
Fee summary Charged Paid Credited Due
Permit Fee Total 99.00 99.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 4.00 4.00 .00 .00
Grand Total 103.00 103.00 .00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
��� This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
A11 ■..I C E RT I F I E D 7M between Feb 17, 2009 and Dec 31, 2011.
www.ahridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 4151176 Date: 8/2/2011
Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source
Outdoor Unit Model Number: 4TWB4036E1
Indoor Unit Model Number: GAM5A0B36M31
Manufacturer: TRANE
Trade /Brand name: XB14 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 36000
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh) @ 47 F: 33000
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh) @ 17 F: 22800
* Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate.
DISCLAIMER
AHRI doss not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all Ilabiity for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized akeratlon of data listed on this Certificate. Csrtlfisd ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Graffcabs and Its contents are proprietary products of AHRI. This Certificate shat only be used for indhridual, personal and confidential reference purposes.
The contents of this Certificate may not, in whole or in user's re personal coed; confidential di m rated; entered into a computer database; or otherwise utilized. In any
tom fo or manner or by any means, except ua
CERTIFICATE VERIFICATION Air - Conditioning, Heating,
The information for the model tied on this certificate can be verified at www.ahridirectory.org, - '
click on "Verify Certificate^ ink and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute
which the certificate was issued, which is listed above, and the Certificate No., which is listed below.
02011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129567621166162660
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247 Fax (904) 247 3 ^ ` - 3 2 OB ADDRESS: 131 0Ce Q �)J uct 4/I4Pi iCo � PERMIT #
PROJECT VALUE$ ' ) 965 - 4 00
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INST A A ` � T , ON
Air Conditioning: Unit Quantity 1 Tons Per Unit 3 REQUIRED
Heat: Unit Quantity 1 BTU's Per Unit 36 ) (no Seer Rating 15
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU' s
Elevators /Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU' s
# Water Heaters Solar Collection Systems
Tanks (gallons)
1 Wells
OTHER: Qoed -Q$ tib1 3ux± S'l 5*PL -
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name aIn 1 �x5 V r l') C Inc- Phone Number 0- 30g l�
99 CIv . Off ice Phone 171 101
Mechanical Company � a�1 U � Fax r
Co. Address: 39 m O l+tU C . ( 1� t( City State 4I Zip "7
E i t / License Holder (Print): +' are® )0k., «mil . y State Certification/Registration #C)10_124).-99.9
Notarized Signature of License Holder X A)1,1
S.,t-
Sworn and subscribed b fore m th l � day of l LA. 5- 20 1 1
(, I NDA S. WOODARD
Signature of Notary Public . my COMMISSION # DD732186
°•,, EXPIRES November 06, 2011
(407) -0163 FloridallotaryService.com