Loading...
3 FY12Public Utilities Budget Public Utilities BudgetFY 12 Current FY Project StatusProjectCurrent FY AmountStatusWell No. 1 Rehabilitation$51,026UnderwayWaterPlant 2 & 4 Tank Repairs/Rehabilitation$47,790Underway11thSt. Water Main Replacement$120,000Bidding SelvaMarina Sewer Rehabilitation$286,727CompleteDonner Subdivision Sewer Rehabilitation (Grant)$178,000Bidding(Re-Bid)Replace YardStation Equipment$40,000Under ConstructionTMDL Project –Force Main$1,403,656CompleteTMDL –WWTP#1Upgrades with Sludge & Odor Control$8,344,644UnderConstruction TMDL Project SummaryDEPDeadlineComplete Construction12/31/2012Begin Operation of Upgraded WWTP3/31/2013OperationalLevel to Remove Nitrogen Attained10/1/2013Project StatusForcemain constructionComplet eWWTP #1 UpgradesConstruction underway, approximately 35% completeSludge & Odor ControlNoticeto Proceed 7/20/2011 TMDL Project Description•Consolidating two wastewater treatment plants to a single plant•Transferring flow from smaller plant with limited space and aging metal tanks to main plant with newer, large concrete tanks that could be modified for nitrogen removal•Used directional drilling technology for force main installation to avoid environmental damage and neighborhood disruption•Installing state-of-the-art equipment for electrical efficiency •Included more efficient, effective sludge treatment and odor control TMDL Construction Cost Savings•SJRWMD Grant of $1,000,000•Other funding with State Revolving Fund Loan with much lower interest rates•Received excellent construction prices due to bidding while the market was right•Major equipment procurement process resulted in excellent pricing for equipment TMDL Operational Cost Savings•Consolidating treatment plants results in more efficient operations and cost savings•New equipment is much more efficient, resulting in electrical savings•Estimated operational savings is $340,000/year•Pro-rated savings in FY12 Budget is approximately $110,000.•New sludge treatment process will result in major savings in tipping fees if implemented by COJ Water Master Plan Status•Some recommended projects have been delayed due to reduced funding, but progress still being made. Since the 2001 Plan we have:▫Interconnected the Buccaneer & Atlantic Beach Water Systems▫Added a 300,000 gallon elevated storage tank at Water Plant #2▫Replaced old cast iron water mains with new PVC mains in several areas of the City▫Updated the Water Distribution System Model in 2007.▫Constructed a new well and rehabilitated another well. Water Master Plan Future Issues•Continue with Well Evaluation, Rehabilitation, Replacement •Continue replacing aging or undersized water mains•Many major problem areas are complete. Fewer water breaks, combined with sewer rehabilitation improvements have reduced emergency issues. Staff suggested a reduction of one field position by not replacing a retiring employee. Water Loss•Enhanced meter replacement program in FY11. Analysis of a small sample indicated approximate 5% payback.•Accelerating program in FY12 to approximately 800 meters ($74,000)•Will continue with annual leak detection and large meter testing and repair Water Capital Items for FY12•Interior rehabilitation of elevated tank at Water Plant #1 -$40,000•Interior rehabilitation of ground storage tank at Water Plant #2 -$40,000•Recoat both ground storage tanks at Water Plant #3 -$60,000•Replace old water mains on 12thSt. between Ocean Blvd. & Beach Ave. and on Ocean Blvd. between 14thand 16thStreets -$200,000 2006 Sewer Master Plan Status•Recommended lift station improvements have been completed (Lift Station E at 799 Mayport Rd. and Mimosa Cove Lift Station in FY10).•Sewer rehabilitation in much of the Atlantic Beach system has been completed.•Grant funding has paid for sewer rehabilitation in the Salt Air area, and another project being bid in the Donner Subdivision. Sanitary Sewer Rehabilitation –Status at 2006 Sewer Master Plan Sanitary Sewer Rehabilitation –Status FY 2011 Sewer Capital Items for FY12•Continue sewer rehabilitation in Area B (North of Core City) -$300,000