Loading...
Permit Mech 141 Jasmine 2011 t -1-4- Jr iel I A CITY OF ATLANTIC BEACH . - '' 800 SEMINOLE ROAD 5 1 " ATLANTIC BEACH, FL 32233 . '' ,, ' 09 INSPECTION PHONE LINE 247 -5814 Application Number 11- 00002545 Date 8/25/11 Property Address 141 JASMINE ST Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor VIRGEN, RIVERA FROSTY AIR CONDITIONING & HEAT 141 JASMINE STREET P 0 BOX 16334 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32245 (904) 568 -4204 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 91.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 2/21/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Bea:h, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: /// la S an ! H C., c, f PERMIT # P OJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM NSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATIN SYSTEM INS • IAT • Air Conditioning: Unit Quantity RI # 3 00 ir g Q ty � Tons Per Unit c>/- � REQUIRE t Heat: Unit Quantity / BTU's Per Uni I See -- ; -2 -. Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty___ Automo pile Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING eat Elevators/Escalators Exchanger H Quantity of Outlets Heat E Pumps # Vented Wall Furnaces # Water Heaters Refrigerator Condenser BTU's Solar Cc llection Systems Tanks (gallons) Welts OTHER: Permit becomes void if work does not commence within a six month period or work is susr ended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company 6s� y �/G q2, p l / >h y _..2.- c Office Phor :s �_93Y3 / /4 S/ Co. Addres /iir (ikoa,,U azir [i/ M /d/ City jac kc'd)7 vi /I p State Zip o2 a 2 / License Holder (Print): N \ k (,/ c a p u S a_ State Certification/Registration # ('.. C 111 t f( 9 Notarized Signature of License Holder 2v ' ‘- I 1 --\_,,,_ .--- s' :4;: :k SH • '''.4-6 : r e • ...ribed befor= m: y o _ i� "tv CO SSION DD 9577 ,� 20 xalR 17:iNcary • Publ . • -'.$, N;T` Bonded Thru Notary Public Unde wr ters ` � �� , . AI 9R CERTIFIEDTM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3001449 Date: 8/25/2011 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: GSZ130241A* Indoor Unit Model Number: AWUF24XX16A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 22600 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 23000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 13400 Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air - Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on i* so and Refrigeration institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129587569325972500