Permit Mech #1 469 Atlantic 2011 f 0 ! j'ily feel
:t, CITY OF ATLANTIC BEACH
s1 800 SEMINOLE ROAD
" ' -' ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247 -5814
Application Number . . . . . 11- 00002587 Date 9/07/11
Property Address 469 ATLANTIC BLVD UNIT 01
Tenant nbr, name MYA NAILS
Application type description MECHANICAL HVAC ONLY
Property Zoning TO BE UPDATED
Application valuation . . . 2000
Application desc
CHANGE OUT CONDENSOR
Owner Contractor
LAURA PLAZA, INC PORTSIDE MECH SERVICES
7880 GATE PKWY SUITE 300 5285 SHAD RD
JACKSONVILLE FL 32256 ORANGE PARK FL 32003
(904) 644 -7568
Permit MECHANICAL HVAC PERMIT
Additional desc . CHANGE OUT ROOF TOP CONDENSER
Permit Fee . . . 95.00 Plan Check Fee . . .00
Issue Date . . . Valuation . . . . 0
Expiration Date . 3/05/12
Other Fees STATE MECH DCA SURCHARGE 2.00
STATE MECH DBPR SURCHARGE 2.00
Fee summary Charged Paid Credited Due
Permit Fee Total 95.00 95.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 4.00 4.00 .00 .00
Grand Total 99.00 99.00 .00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247 -5826 Fax (904) 247 -5845
JOB ADDRESS: T49 7 fit4, 1515/V1J (./. r t 4 r PERNHT #
7/ 3? ).1-.33 Y oc.)
PROJECT VALUE $ 87000
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity eit / Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating /3
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI #
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name •Z‘ Lcst P / Phone Number q'? 2 _. (,CJU
Mechanical Company Poi. Q e/ y t��.. Office Phon 6 '2 ax �oy`�S�f
Co. Address: 5»? , A 0/ 14 2®& City Jay-- j Zip3-
License Holder (Print): tev1Yi l Yq /,-- State Certification/Registration #4D s
Notarized Signature of License Holder /�.�,,,,: o.._, /--
Sworn and subscribed before 'i t � ^ l da of 74 2d (/
Signature of Notary Public 6 2
I r � 'L
International t oir. hrt Products
May 8, 2009
Betsy Herndon
Regional Business Manager, ICP — Florida
650 Heil- Quaker Blvd
Lewisburg, TN 37091
813- 597 -8219
RE: Combining new R22 outdoor units with existing indoor units
Dear Betsy,
Although ICP Residential Systems recor`imends installing only AHRI approved matched
indoor coils with all new AC and HP outcoor products, in some situations, replacing an
existing indoor coil with a new indoor coil' is ri ;: t an option. In these cases, ICP will allow
new R -22 outdoor units to be matched with al existing indoor coil that was
manufactured no earlier than 1992. The iexist'ng indoor coil nominal capacity should be
a straight match or one size larger than the r +Qw outdoor unit.
It is highly recommended that the old inc!oor be fitted with an R - 22 thermal
expansion valve metering device to deliver th; best possible efficiency and reliability
from the mix - matched system.
Coils with capillary tube expansion devices are not ermitted. Please lease note that ICP
will not provide ratings or capacities for <itny r' --'.w outdoor products combined with
existing indoor coils
Sincerely,
,'
Robert L. Lambert
Application Engineer
ICP Residential Systems
CC: Mike Robertson, JT Holtschlaq, Charlie Pirahian
International Comfort Products LLC