Permits 480 Ocean Blvd (vault) CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 06-00032897 Date 5/02/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . POOL WIRING
Application description . . . ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI BARKOSKIE ELECTRICAL SERVICE,
480 OCEAN BLVD. INC.
JACKSONVILLE FL 32223 48 S . PENMAN ROAD
JAX BEACH FL 32250
(904) 246-4731
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 75 . 00 Plan Check Fee .00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 75 . 00 75 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 75 . 00 75 . 00 . 00 . 00
PERMT IS"PROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
Bull OFFICIAL
CITY OF ATLANTIC BEACH
ELECTRICAL PERMIT APPLICATION
Date:
Property Address:
Owner: Nr Telephone#:
Contractor. Telephonek
Contractor Address: Uez-zlee- V_"A Fax#: )-2'f—,PV 7
In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in
accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach
-ordinance and standards of good practice fisted therein.
Building: Building Type: C) Trailer Service: If other construction is
0 New CI Residence 0 Temp. 13 New being done on this building
Or site,list the budding
c3 Old CI Commercial 0 Signs U Increase Perrrut nwnbcr.
El Re-wire Q Addition Sq. Ft. C3 Repair JZ!k�
-Conductor Size: ANTS: COPPER El ALUMINUM PK
Switch or RACE
-Breaker ANVS Af d PH W VOLT WAY
Existing Service RACE
Size AMPS PH W VOLT It-Ile) WAY
Feeders: NO. SIZE NO SIZE NO SIZE
Lighting Outlets
CONCEALED OPEN
Receptacles CONCEALED OPEN
Q 10 AMPq It I nQ AMPR
Switches
Incandescent
Fluorescent &
M.V.
Fixed 0.100 AMPS OVER BELL
-Appliances TRANSFER.
Air H.P.RATING H.P.RATING CEILING KW-HEAT
Conditioning COMP. MOTOR OTHER MOTORS AMPS HEAT
-Motors 0-1 H.P. VOLTAGE PH NO. OVER I H.P. PHS
UNDER600V OVER600V
-Transformers NO. KVA NO. KVA
No.Neon Transf
-Ea. Sign
-Miscellaneous
800 Seminole Road-Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800 9 Fax: (904)247-5845 9 http://www.ci.atiantic-beach.fl.us
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 06-00032388 Date 3/01/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . INSTALL SWIMMING POOL
Application description . . . POOL
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 15000
Owner Contractor
------------------------ ------------------------
PORCELLI , ARTHUR BONAFIDE POOLS
480 OCEAN BLVD. 2210 FLORIDA BLVD.
JACKSONVILLE FL 32223 NEPTUNE BEACH FL 32266
(904) 247-1313
-------------------- --------------------- -----------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 105 . 00 Plan Check Fee 52 . 50
Issue Date . . . . Valuation . . . . 15000
Fee summary Charged Paid Credited Due
-------------- --- ---------- ---------- ---------- ----------
Permit Fee Total 105 . 00 105 . 00 . 00 . 00
Plan Check Total 52 . 50 52 . 50 . 00 . 00
Grand Total 157 . 50 157 . 50 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
N,
,14 1
BUILIAM 6fMIAL
CITY OF ATLANTIC BEACH Cc:
BUILDING / ZONING DEPARTMENT Q. Ford.
S
800 Seminole Road r
Atlantic Beach,Florida 32233
(904)247-5800
(904)247-5845 Fax
www.coab.us
PLAN REVIEW COMMENTS
Permit Application # D(J2
Property Address: -46D oxan vou
Applicant: ftrz)- 0-y6�ifs -4 nin
f J Poo
Project: �55w' W W 1,
J
T7rmit application has been:
APproved
F-� Reviewed and the following items need attention:
Please re-submit your application when these items have been completed.
Reviewed By: VA-� Date: -;kfutof'
Date Contractor Notified:
CITY OF ATLANTIC BEACH
POOL PERMIT APPLICATION
Date:
Please submit(2) complete sets of plans with ann 5 cation
Job Address: q<0 0/6,14" T� 17�
Owner: V z toe."I �-e- I I,.-- Phone:
Contractor: 4�C A� Phone:
�e,
Address: Fax: 1ZDL-t9- 1283
City : n C- c State:Q—Zip Code: 31�-
Valuation of Proposed Construction: -Y)() Gallons: -
*Impervious Surface Calculation: 1431t)
0 Swimming pools shall not be considered as Impervious Surfaces because of their abilitY to
retain additional rainwater, however, decking around a pool may be considered impervious
depending upon materials used TUv calculation should re the totai area of hn ervions
X_
stir ace to be added under this Permit.such as sidewalk. 'Cooldeck .,vavers, etc.
Is approval of Homeowner's Association or other private entity required? Ab—. If yes,
please submit with this application.
In consideration of permit given for doing the work as described in the above statement,we hereby agree to
perform said work in accordance with the attached plans and specifications which are a part hereof and in
accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein.
Procedure: In order to expedite issuance of permits,please follow all steps and provide all
information as MpE2pn te. Incomplete applications may result in delay in issuance
:a
of permit.
I. Recent Survey-including all existing impervious areas.,-with calculations showing
percent of lot coverage.
2. Two(2)complete sets of plans. One(1)copy must be a raised seal engineering drawing.
3. Recorded Notice of Commencement.
4. Tree Removal Application if trees are to be removed or relocated.
Scheduled Inspections:
Requests for inspections are taken from 8:00 a.m. to 5:00 p.m. Monday through Friday at 247-5826.
Requests can be scheduled after hours by leaving a message on the voice mail system. Inspections are
made the following workday; please specify a.m. or p.m. inspection. When calling in an inspection please
have the permit number,job location and type of inspection needed. Inspections are scheduled as follows:
1. Steel
2. Pool Electric
3. Final
BUIELDING CARD MUST BE POSTED OR NO INSPECTIONS WUL BE MADE. A fee of$35.00
is charged for all re-inspections.
800 Seminole Road-Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800- Fax: (904)247-5845* http://www.ei-atiantic-beach.fl.us Revised 8/04
I hereby certify that all inform eionprovide wi thi I s)app lication is c Ic
L 0
Signature of Owner: Date:
77
I hereby certify that I have read and examined this application and know the same to be true and
correct. All provisions of the laws and ordinances governing this type of work will be complied with,
whether specified herein or not. The granting of a permit does not presume to give authority to
violate or cancel the provisions of any federal,state or local rules, regulations, ordinances, or laws in
any manner, including the governing of construction or the performance of construction of the
property. I understand that the issuance of this permit is contingent upon the above information
being true and correct and that the plans and supporting data have been or shaH be provided as
required.
Signature of Contractor:
—Date: 1--4
AS TO OWNER:
Sworn to and subscribed before me this day of 200(,,
State of Florida,County of Duval 0
Notary's Signature:
Cynthia A Dymon / ersonally
MYCOMMIS&ON# DD259940 EXPIRES P
October 2Z 2007
BONDED THRU TROY FAIN INSURANCE INC El Produced Identification
Type of Identification Produced
AS TO CONTRACTOR:
4
Sworn to and subscribed before me this pzyd day of 20(9
State of Florida,County of Duval
V1
-4/_
Notary's Signature: UiA�I
Ell"Personally kno'Zi
Cynthia A Dymon Produced Identification
MYCOMMISSION# DD25n4o EXPIRES
October 2Z 2007 Type of Identification Produced
BONDED THRU TROi FAIN INSURANCE INC
800 Seminole Road -Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800* Fax: (904)247-5845- http://www.ci.atlantic-beach.fl.us
Revised 8/04
Address and contact information of person to receive all correspondence regarding this application(please print).
Name:
Mailing Address: V-5 2 15161;_, -71, s
le- �< Fax: E-Mail:
Phone: #.� C —It
AS TO OWNER:
Sworn to and subscribed before me this day of 20 (a.
State of Florida,County of Duval
Notary's Signature:
Cynthia A Dymon
MYCOMMISSIONif DD259940 EXPIRES
D/Personally known
October 2Z 2007
BONDED T14RU TROY FA#4 INSURANCE INC Produced identificion
Type of identification produced
AS TO CONTRACTOR:
Sworn to and subscribed before me this -�,td day of
&q
State of Florida,County of Duval
Notary's Signature:
G2�Personally know4n
F-1 Produced identification
Type of identification produced
PAV Cynthia A Dymon
CFL- -.751 MYCOMMISSI # DD259940 EXPIRES
ON
.4
October 2Z 2007
BONDED THRU TROY FAIN INSURANCE INC.
800 Seminole Road Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800 Fax: (904)247-5845 - http://www.ei.atlantic-beach.fl.us
Page 2 Revised 1/30/03
CITY OF ATLANTIC BEACH Cc:
BUILDING ZONING DEPARTMENT
800 Seminole Road
-7
Atlantic Beach,Florida 32233
(904)247-5800
(904)247-5845 Fax
www.coab.us
PLAN REVIEW COMMENTS
Permit Application #
Property Address: 4M Wald, 621 vd-)
Applicant: c�4T
Project:
This permit application has been:
[a�pproved
13 Reviewed and the following items need attention:
Please re-subm
B
Y.
p cation�when these items have been completed.
Reviewed Date:
Date Contractor Notified:
CITY OF ATLANTIC BEACH
POOL PERMIT APPLICATION
Date: Oil 0
Please submit(2) complete sets of plans with apnlication
Job Address: bilin obn(4 K-,�
J Phone:
Owner: v / A,
. :PC
Contractor: �e,4! e�e 1_,— Phone:
Address: 0- Fax: - ,--DL4C1- 128-3 ,
City : State:i�Zip Code: 3c;,�- C
Valuation of Proposed Construction: ot)() Gallons:
*Impervious Surface Calculation: 4 3 10
Swimming pools shall not be considered as Impervious Surfaces because of their ability to
retain additional rainwater, however, decking around a pool may be considered impervious
depending upon materialslused Tjli,� etdculation should iy eel the iotai aren of impervions
SIM ace io be added under this permit, sych as sidewo-A. 'CooLdeclf'.oaverselc.
Is approval of Homeowner's Association or other private entity required? A9-- If yes,
please submit with this application.
In consideration of permit given for doing the work as described in the above statement,we hereby agree to
perform said work in accordance with the attached plans and specifications which are a part hereof and in
accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein.
Procedure: In order to expedite issuance of permits,please follow all steps and provide all
information as appro riate. Incomplete applications may result in delay in issuance
of permit.
I. Recent Survey—including all existing imRervious areas,with calculations showin2
percent of lot coverage.
2. Two(2)complete sets of plans. One(1)copy must be a raised seal engineering drawing.
3. Recorded Notice of Commencement.
4. Tree Removal Application if trees are to be removed or relocated.
Scheduled Inspections:
Requests for inspections are taken from 8:00 a.m. to 5:00 p.m. Monday through Friday at 247-5826.
Requests can be scheduled after hours by leaving a message on the voice mail system. Inspections are
made the following workday; please specify a.m. or p.m. inspection. When calling in an inspection please
have the permit number,job location and type of inspection needed. Inspections are scheduled as follows:
1. Steel
2. Pool Electric
3. Final
BUI[LDING CARD MUST BE POSTED OR NO INSPECTIONS WILL BE MADE. A fee of$35.00
is charged for all re-inspections.
800 Seminole Road e Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800- Fax: (904)247-5845- http://www.ci.atlantic-beach.fl.us Revised 8/04
I hereby certify that 0 7infornm ion provid wi this)ap lication is crrfe�ct
Signature of Owner: Date: L -2- -O
I hereby certify that I have read and examined this application and know the same to be true and
correct. All provisions of the laws and ordinances governing this type of work will be complied with,
whether specified herein or not. The granting of a permit does not presume to give authority to
violate or cancel the provisions of any federal,state or local rules, regulations, ordinances,or laws in
any manner, including the governing of construction or the performance of construction of the
property. I understand that the issuance of this permit is contingent upon the above information
being true and correct and that the plans and supporting data have been or shall be provided as
required.
TLSignature of Contractor: Date: 1--4 &
AS TO OWNER:
Sworn to and subscribed before me this �-�-Z) day of k�L",Ml 20 j9
State of Florida,County of Duval
Notary's Signature:
Cynthia A Dymon WIly
Perssonally
MYCOMMISSK)N# DD25"40 EXPRES
October 2Z 2007
1�t Ar, BONDED THRU TROY FAIN INSURANCE,INC. E) Produced Identification
Type of Identification Produced
AS TO CONTRACTOR:
Sworn to and subscribed before me this 0��d day of 20
InA
State of Florida,County of Duval
Notary's Signature: J
ET-'Personally knowZ/
."0 11,
Avin,N11, Cynthia A Dymon
Produced Identification
MYCOMMISSION# DD259940 UNRES
October 2Z 2007 Type of Identification Produced
BONDED THRU TROY FAIN INSURANCE INC
800 Seminole Road*Atlantic Beach,Florida 32233-5445
Phone:(904)247-5800* Fax: (904)247-5845* http://www.ci.atlantic-beach.fl.us
Revised 8/04
Address and tact information of perso to receiT 111 correspondence regarding this application(please print).
Nai
Mailing Address: 47,
Phone: Fax: <_ E-Mail:
AS TO OWNER:
Sworn to and subscribed before me this day of 20
State of Florida, County of Duval
Notary's Signature:
6 Cynthia A Dymon
"P.
MYCOMMISSION# DD259940 EXPIRES
E3"/Personally know4n
_V, ..6. October 2Z 2007 Produced identific ion
, 7,
BONDED THRU TROY FAIN INSURANCE,INC F
Type of identification produced
AS TO CONTRACTOR:
Sworn to and subscribed before me this day of 120,0
State of Florida,County of Duval
Notary's Signature: h 14,
12/personally known
F-1 Produced identification
Type of identification produced
Cynthia A Dymon
# DD259940 EXPIRES
MYCOMMISSION
zz_ October 2Z 2007
BONDED THRU TROY FAIN WSURANC�INC
800 Seminole Road Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800 Fax: (904)247-5845 - http://www.ci.atiantic-beach.fl.us
Page 2 Revised 1/30/03
eo -06
u e- We
24
s Cle a,?e-r
�F7
Woe-: P,�7e
?. 40 P11C A/15/-
Sk.�-11 be P--ole-c/e& /-Y 4r.01)
A-BC 4,f 4. e. FOOL r-019
14
Pool 430 OceaI7 vd, �Z,9-,Mcl 6,?l
T&IO-7 0 Ve r: 0 hr5.
A021
'70
01-
tie
F M,
09
Ogg
<1 41
vj, Trd
45�
I
Jill;
dx
ioad LA/4�72C
Approve'd Swimming Pool, Spa and Wading Pool
"Dual Main Drain Atmostherpic Vent Arrangement
Complaint with 424.2.6.6 of the Florida Building Cod
0%0, Minimum
-6-- , _f
!!!!�Turn
(TypJ ASIAEANSI A112.19.SMIV87 listed Grates
with rn4lichil'19 Main Vvsin Sumps
Z'T (Typ, 2 Plac*sl
2- 2"
Maximum d1slance to
Vent 700 Connection V-0,
9–
AO
/17
2' Suction Piping 1 112" Vent Piping
-Maximum Underwatert length
of vent piping 30 feet
..*—Vent to Atmosphere
In a manner that the went
will not he blocked by Infestation.
debris build-up. of microbiological
Contamination.
Pump ru L ebe) vent: 'POOL SAFETY DEVICE 00 NOT HANDLE'
No Scale
-MAP SHOWING BOUNDARY SURVEY OF
LOT 5 BLOCK 23 ACCORDING TO THE PLAT OF
SURDEVISEON "A" ATLANTEC REACH
AS RECORDED IN PLAT BOOK 5 PAGE(S) 69 OF THE CURRENT
PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
CERTIFIED TO: ARTHUR PROCELLI,
STEWART TITLE GUARANTY COMPANY, WATSON & OSBORNE TITLE SERVICES, INC.
AND OCEANSIDE BANK.
FIF "rH SIrREEY
40' R/W
3/4"
NNW
10 This sub Ised
zoning,
[I. mom bw ds"to
4=11 for" Issuance Of
with Florid*BuI10"Code-wId At 0Af0hWw
local, State and F
must be d of I" Aftnft
LOT 6 Beach B
BLOCK 23 Building Sm
Approved By.
Of"
Dote:
LU 4
15' (R) . I
�-:- 3.2'
0.2'
w'w U
0- 4
ro - C r-: 32.0'
0.1' 12.0' 40.6' 0) .
0 15 '0 LOT 5
0 .0, Uj >
0 BLOCK 23
.4 Z Uj
CONCRETE 0
COVERED WALK J
T1
_j 1 STORY BRICK 11 9. 20.0'
(L 0.4! RESIDENCE 0 Irf
10 1
Lj NO. 480
I " .. . 0
(ZO' EAVES) 0 g 0
CONCRETE Lr) LO
DRIVE
%
65.1'
AC BCONCRETE 7206!0' '90 0
PAD PAD CONCRETE 01s. w
Uj 1.3' PAD n n
CO -1L 3.0' U
J 1/2"
Cy IR
6 114.99' (M) 0
r4C3 115' (R)
Z r")
1/2"
0
_j LOT 4
BLOCK �3
E Y 0
GENERAL NOTESs
1. MMES ARE SHOWN FOR 'MIS SURVEY
2.STRUCTURE NO. 480 SHOYM HEREON LIES WITHIN FLOOD ZONE X AS BEST
SURVEYORS INC. DETERMINED FROM F.E.M.A. FLOOD MAPS PANEL NO. I DATED04-17-1989
LAND & ENGINEERING SURVEYS 3.THIS IS A SURFACE SURVEY ONLY. THE EXTENT OF UNDERGIRKU-N-D FOOD
PIPES AND UTILITIES, IF ANY, NOT DETERMINED.
3846 BLANDING BOULEVARD 4.JURISDICTIONAL AND/OR ENVIRONMENTALLY SENSITIVE AREAS IF ANY, NOT
JACKSONVILLE, FLORIDA 32210 LOCATED BY THIS SURVEY.
904-771-6468 5.THIS SURVEY BASED ON LEGAL DESCRIPTIONS FURNISHED. THE PUBLIC
0 CERTIFICATE OF AUTHORIZATION NO. LB 0005488 RECORDS WERE NOT SEARCHED*BY THIS SURVEYOR FOR EASEMENTS,
s V TITLE, COVENANTS, RESTRICTIONS, CLOSURES, TAKINGS OR ORDINANCES, ETC.
THERE COULD BE OTHER MATTERS OF RECORD THAT AFFECT THIS PARCEL
I HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY 6.UNLESS OTHERWISE STATED ALL IRON PIPES FOUND HAVE NO IDENTIFICATION.
DIRECT SUPERVISION AND MEETS THE MINIMUM TECHNICAL
STANDARDS FOR LANOSURVEYING P RSUAN TO CHAPTER -0 - GUY ANCHOR Lr.QRNI)/A5wI1VIATI0N0 (R) - RECORD
61G�*6. FLORIDA INIS !ON C E. C1 TER 472. F.S. 0 =SET IRON PIPE OR REBAR MARKED P.C.= POINT OF CURVE (M)-MEASURED
ASSOC. SURVEY " OR L.B. 5488 P.T.-POINT OF TANGENCY A - CENTRAL
FOUND IRON PIN OR PIPE C/L - CENTERUNE MCLE
FOUND CONCRETE MONUMENT I.P.= IRON PIPE OR PIN L-ARC LENGTH
BY: CHARLES B. HAICHO' FLORIDA VkTIFICATE NO. 3771 X CROSS CUT OR DRILL HOLE R/W RIGHT OF WAY R- RADWS
I P.R.C.- POINT OF REVERSE CURVE W WIRE FENCE 0 - WATER
By: CHARLES L. STAR4NG FLORIDA/CERTIFICATE NO. 4579 P.C.C.- POINT OF COMPOUND CURVE 0-0- WOOD FENCE METER
BY: RAYMOND J. SCHAEFER FLORIDA CERTIFICATE NO.1 6132 B.R,L - BUILDING RESTRICTION LINE CONC.- CONCRETE G - WELL
JOB NO. 46304 DATE 07-22-2005 LI(ORS) = OFFICIAL RECORDS BOOK X-X-CHAINLINK FENCE * - STREET
SCALE: 1 20' DRAFTER C.L.S. (ORV) - OFnCIAL RECORDS VOLUME cCL) = UTILITY POLE LIGHT
J.EA =JACKSONVILLE ELECTRIC AUTHORITY OU--OVERHEAD UTILITIES
NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAJSED SEAL OF A FLORIDA UCENSED SURVEYOR AND MAPPER
1_4
tv
LNII
V-f
Z �.:5
NOTICE OF COMMENCEMENT
Permit No. Tax Folio No.
Doc#2006067753,OR BK 13094 Page 555,
Number Pages:1
Filed&Recorded 02/27/2006 at 12:29 PM,
JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY
lie undersigned hereby infornis all concerned that improvements will be RECORDING$10.00
)certain real property, and in accordance willi Section 713-13 of(Ile Flo
tames(revised 10-1-96), it - f 11 1 , ' if ation is stated;
IF o oNying n oiTn
4ner's name(print) V- e) 0
Adress J-1� 0 0 e a-, _d ,
)wner interest in property yk
ieneral description of improvement VV ., ry) /4
,egal description of property
'cc simple title holder(if other than owner):
qarne(prilit)
j,011tractor(print) P.v e,��j,L.
kdd.ress P71 I
rriephone 6%4j Fax CD_ (A-46
;Urcty(if ally)(print) Amount of Bond
kddress
releplione Fax
Person or tender making a loan for construction of improvements:
Name(Prillt)
Nddress
1'elepholle L-) Fax
Persons within the Stale of Floritla designated by owner upon whom notices or other documents may be served as provided by
�larnc(Print)
kddress
releplione Fax
n addition to hiniself, owner designates the following person to receive a copy of the lienor's notice as provided in Section
'13,13(l)(b),Florida Slatiaes(fill in at owner's option):
iarne(Print)
,ddress
clephoric —Fax
1)Ile
Owncj�s Signature Date Mgned
Pzay e
Owner's fqalllc (print) In County Named Of State
Angem j.js&Aon
laic of Floi-ida Y W cotZ,
ExPkn June 12,2W
lie foregoin *11ment was a ledged before me 7 Notary Public
d a y o f Loo or,L.-
kc,
who is personaTly (name 4,Nolary, typed or printed)
iown to me or who has produced__ Commission Number
as ideutification. Commission Expires_
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . OS-00031564 Date 1/11/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . ADD 2ND FLR OVER 1ST FLR
Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 190000
Owner Contractor
- ----------------------- ------------------------
PORCELLI R. S . PENNINGTON CONSTRUCTION
480 OCEAN BLVD. 380 13TH AVE N
JACKSONVILLE FL 32223 JAX BEACH FL 32250
(904) 993-2000
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . .
Sub Contractor . . NICK' S SOLAR & AIR SYSTEMS
Permit Fee . . . . 123 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 123 . 00 123 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 123 . 00 123 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUILDINCOP"'CIAL
CITY OF ATLANTIC BEACH
MECHANICAL PERMIT APPLICATION
Date:
Property Address: wo cc 1L=L/a
Owner: Telephone#: .2 2�2 IOU
Contractor:
..''6 C!�Lj JA,ifelephone
Contractor Address: I.J,2 u Fax#:
Contractor Signature: ,61
In consideration of permit given for doing the��&rk as described in the above statement�we hereby agree to perform said work in accordance
with the attached plans and specifications which are a part hereof and in accordance with die City of Atlantic Beach ordinances and standards of
good practice listed therein.
Type of Heating Fuel: If other construction is being done on this building
0 Electric or site,list the building permit number:
La Gas: —LP —Natural —Central Utility
• Oil
• Other—Specify_
MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK
• Heat Space Recessed Central —Floor Residential
• Air Cond-itioning: Room Central X
C3 Duct System: Mat�r7tal ------ ickness-4-6- 0 Commercial
-Maximum capaci P11
,120-p—arn Ll New Building
• Refrigeratiok- 0 a 0
• Cooling Tower: Capacity Ll Existing Building
El Fire Sprinklers:Number of Heads
• Elevator: —- Manlift Escalatoi�—(Number) Ll Replacement of Existing System
• Gasoline Pumps —(Number)
• Tanks - I (Number) New Installation
• LPG Containers —(Number) X (No system previously installed)
C3 Unfired Pressure Vessel U Extension or Add-on to Existing System
C3 Boilers
E3 Gas Piping Q Other-Specify_
Ll Other-Specify_
LIST ALL EQUIPMENT
AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSORIS Approving
Number Units Description Model# Manufacturer Ton's Agency
24
L/
HEATING-FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving
Number Units Description Model Manufacturer BTU's Agency
3 0 3XZ0
-2 4WQ
e--2 W%le -
TANKS Nominal Capacity Type Liquid -. Serial Approving
How Many &Dimensions Contained Manufacturer — No. Agency
800 Seminole Road 9 Atlantic Beach,Florida 32233-5445
Phone: (904)247-5800* Fax: (904)247-5845 e http://www.ei.atlantic-beach.fl.us Revised 1/04
I I J'i
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 06-00033234 Date 7/25/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name INSTALL PAVERS
Application description . . . RIGHT OF WAY PERMIT
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI, ARTHUR OWNER
480 OCEAN BLVD.
JACKSONVILLE FL 32223 ATLANTIC BEACH FL 32233
----------------------------------------------------------------------------
Permit . . . . . . DRIVEWAY PERMIT
Additional desc . .
Permit Fee . . . . 35 . 00 Plan Check Fee .00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 35 . 00 35 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 35 . 00 35 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
CITY OF ATLANTIC BEACH
PLAN REVIEW SHEET Routed to:
S.Makowski
Building Department Public Works&Public Utilities Departments L. Higgins
800 Seminole Road 1200 Sandpiper Lane
Atlantic Beach,Florida 32233 Atlantic Beach,Florida 32233
(904)247-5800 (904)247-5834 D. Kaluzniak
(904)247-5845 Fax (904)247-5843 Fax Public Safety
PLAN REVIEW COMMENTS
Permit Application#
Property Address: f) bd V
Applicant: Pace I I ('
Project: Tm5im I I e
his permit application has been:
Approved as noted by the?A.,� Department.
Final application approval must come from the Building Department.
Reviewed and the following items need attention:
Proposed indicated City sidewalk to be replaced with
pavers. Not allowed per City Code 19-7 (h) . Sidewalk� must
remain plain co crete.
4 10.0
04
V
Please re-submit y_qur application when these items have been completed.
Reviewed B :- 1
100, r
Date Contractor Notified: 41 IeJ JUN 16 2000
CITY OF ATLANTIC BEACH
CONSTRUCTION PERMIT WITHIN CITY RIGHTS--OF-WAY AND EASEMENTS
800 Seminole Road 2 V 800
-5445 Fax 904-247-5845
Atlantic Beach, Florida 32233
PLEASE SU13MIT(3)COMPLETE SETS OF PLANS WITH APPLICATION.
Date 5f r,4E, RMIT
PE
ISSUED BY THE CITY
Job Address �Ixo
Permitee: Z/�'�I/"- Telephone
— 1
Permittee Address: 7C/-
Requesting Permission to gonstruct: 1517 6A 141IVc,I Za 61
Z
Location: (Reference to Cross-Street).. /2-0 Ke -�/- 27
1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities,
both aerial and underground and the accurate locations are shown on the sketches-
A Letter of Notification was mailed.to the following Utilities/Municipalities:
Jacksonville Electric Authority Yes ( ) No ( ) Date:
Bell South Telephone Company Yes ( ) No ( ) Date:
Ferrell Gas Yes ( ) No ( ) Date:
Comcast Yes ( ) No ( ) Date:
2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation,
alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public
Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized
hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as
required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is
authorized.
3. All work shail meet City of Atlantic Beach or Florida Department of Transportation Standards and be
performed under the supervision of (Contractor's Project
Superintendent) located at Telephone*
4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee.
5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications
and the manner satisfactory to the city. I hall be made a
6. A sketch of plans covering details of this installation, as wel as a copy of a recent survey s
part of this permit. Calculations showing any increase in impervious area on owner's lot or in the_21ty
Right of'Play are to be included with this application.
7. This permittee shall commence actual construction in good faith with days. If the beginning date is
more than 60 days from date of permit approval, then permittee must review the permit with the Director of
Public Works to make sure no changes have occurred in the area that would affect the permitted construction.
8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the
City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all
times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and
against any and all loss, damage, andc6bt of expenses arising in any manner of the exercise or attempted
exercises by the holder of the fore aid r
�hts and privileges.
9. The Director of Pu i W s all notified nty-four (24) hours prior to starting work and ag
immediately upon om I n. K.CUNNINGHAM
4 Not"pubic-State of FloO
OWNER— Fab 28,2010
J omffftsion Expires
C
.05 -W #oo 523638
S Date:(D somw By National Nolary Assn
B,;fore me day of i the Count pf Duval,
State Of Flo -;R�ally appeared (16MA UK nk/tf-L J
Notary Public at Large,State of Florida_County of Duval.
My commission ex .res- 10 Personally Known:
Produced Identification:
R.O.W.Permit Attachment of for
R.O.W.Permit# issued 2005 Atlantic Beach � 32233
Owner's Name: 1_,�A
Property Address: �Ileel"
Subdivision:
Lot#/Block 4:
R.E. 4:
REVOCABLE ENCROACHMENT PERMIT
THIS REVOCABLE ENCROACHMENT PERMIT, issued on this day of
— , 2005, by Atlantic Beach, Florida, a municipal corporation organized and existing
under the laws of the State of Florida, hereinafter referred to as "CITY" and
of Atlantic Beach,Florida,hereinafter referred to as"USER".
WITNESSETH:
That the CITY does hereby grant the USER permission on a revocable basis as described herein the
right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of
Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached).
This work 1 e Ily lescrib9l as: i),qw-S 7-�
4 /P1141/tf,!fT ^,�'eklllld
r 6 ZZ
Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted
remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to
USER shall be given by certified mail, return receipt requested, to the following address:
The depositing of said notice of cancellation in the United States mail shall constitute the notice of
cancellation and the burden is upon USER to keep the CITY informed of USER's proper address.
The USER shall promptly make any and all necessary repairs to any facility erected or maintained in
the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe
condition.
In the event it is necessary for the CITY or the City's approved representative or other franchised
utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's
sole expense, any and all material necessarily displaced during the action of maintaining, repairing,
operating, replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider.
The facilities allowed by the permit shall meet the current requirements of the City Code, Building
Codes, Land Development Code, and all other land use and code requirements of the CITY.
The USER, prior to making any changes from the approved plans and/or method, must obtain
written approval from the City of Atlantic Beach, Public Works Department, for said change. The
Page I of 2
USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change
within thirty (30) days after the day of completion.
This permit shall inure to the benefit of, and be binding upon, the USER and their respective
successors and assigns.
USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY
laws and/or specifications, to include utilities locate requirements and use limitations/requirements of
public rights-of-way and other public land. USER further agrees that the CITY and its officers and
employees shall be saved harmless by the USER from any of the work herein under the terms of this
permit and that all of said liabilities are hereby assumed by the USER.
DATED and SIGNED this day of Ivy) 200
CITY OF ATLANTIC BEACH,FLORIDA, By:
a municipal corporation: Property IQRGer
By:
Jim Hanson, City Manager
Attest:
Rick Carper, Public Works Director
STATE OF FLORIDA
COUNTY OF DUVAL
110
On this day of 200-��, pe sonally appeared before me, a Notary
P11wic in and for said County and State, 0, _k9fireeill the property owner of
-4bD Wan hlvi , Atlantic Beach, Florida, known to me to be the person(s)
described in and who executed the foregoing instrument; who acknowledged to me that he or she
executed the same freely and voluntarily and for the uses and purposes therein mentioned.
By:
�Notary I/
C
or said County and State P�opKi0w)(ei-L/
(to be signed in presence of the Notary)
K. CU
INN"PW*-oft of Fkft
ca ' *n EVMF*3&
CAmmh"0 DD S231X
�ft NOW NOW AM
Page 2 of 2
UN-01-2006 10 :45 AM SANDYSANL� 904 �e4l
ICOMMMUL I REsiDENTIAL creative ign Pavers, Inc.
2020 arant Loop N.
0115VEWAYS Nopwrie Beach. Fl, 32296 DATE: BRIM
PATIOS Office! 904-242-0079
POOLDECKS Fax: 904-242-0079
RETAIMMG WALL$
P9 'POSAL I ACCEPTANICE
WU'Nam 1)T'd Coll,
Art Poroall! (904) 568-1894
0 L
Ma"! a tamli.:
48 71 n Blvd. Porcelli
0 Ooea
CITY,=%AND ZIP BOD16- Jai ADDRESS:
Atlanfic Beach, Fl. Same
PHONE: FAX CITY,rTATE AND ZIP MOE subdivision.,
270-2250 1270-2261
Interlocking concreft pavers by Tremron-
Stiles: Old Towne cow, TIIID Pattern RoKlon
Border: Bx$ Color. IM Coping NIA
CmtW@ Design Pavers, Inc. will furrilsh and Install Interlocking comeate powers Over a compacted setting bad
appropriate for proper Installation or as per plane end or spealfic"ons.
Install pavers for driveway and front sidewalk-Approx 820 sq ft a 4 4.75 aq ft $ 3,895-00
Install pavers around pool and 3' sidewalk to side door-Approx 862 eq ft 4.75 eq ft 4,094.50
Install 1-3 ft paver step at side door 120.00
Note: Concrete driveway to be removed by others
Paver estimate includes a 7 % waste factor
MOTO:1)AN prices st*04 to&W field mesturnmem
2)A Q we D"n pavers MpnNWft&o GUM NXWM 11111 MWWWW Wait beta slarling.
3)All grading Is to be at mIrm 3-3 I12_Inches and Is the responsibility of(14.to Insure proper sWaftne.
4)AnyaddftkxWjpsd- will beatItte no ofW6,00 per hour.
S)AIlasshtobeg' - In one loceftn to be deposed by Q.QThe disposal of Crs&%Design Pr*ws ftwh will beat the rate of$300.00
6)Cresthe Dealon Parsts,Inc.Is not,am ble for any per"MN under any corodons.
7)Due to color pigmenoMon and leAurs Croadve Design Pswers Is not respors"for varisdons.
WoPrOP069hembyteflurnishinaW and labor-coil piste in accordance with�hom speaffIcaftne,for the sum at.
DOLLARS $ 8,109.50
payment =01CM m%ouverr 11,111clupolcomm.171311
If this Is a credit tmnsaction V*ser"mant top oredit is contained in Q"06r0la dow"m Authodzed
wNch Is incorporated Mmin by rolarenm and is mods a part thereof.INV6 the
underallinod aft horeby authorizing CM&WO DeWan PMM to M*and MVWM MyloLir Slunabla's
WK r=wM
,Zlnds rWlW paring aWcV and relesso ftm from all
nap
lily ad I YwUnt offort, Sandy Sandem
NO WOWA W TO 119 DONE OTHER THAN THAT SPECIFIED Creative Design Pavers
IN THIS CONTRACT WITMOUT ADDMONAL CHARGES.
This agmarrw4listnu annoW and supws6dw any o1w,veftl or othorwise.Sprinkler Aomplad W.
"awns,utift lines andVor arly o0w underground Wift not specifically
to Honed In abomm conuse vAll be do responsilbft af customer and not 096P
clestlys 0061W pavers.hm
P . IMAP SHOWING BOUNDARY SURVEY OF
LOT 5 BLOCK 23 ACCORDING TO THE PLAT OF
SUBDIVISION "A" ATLANTIC BEACH
AS RECORDED IN PLAT BOOK 5 , PAGE(S) 69 OF THE CURRENT
PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
CERTIFIED TO: ARTHUR PROCELLI,
STEWART TITLE GUARANTY COMPANY, WATSON & OSBORNE TITLE SERVICES, INC.
AND OCEANSIDE BANK.
FIFTH STREIET
40' R/W
3/4"
LOT 6
BLOCK 23
ro 114.8W (M)
Lli 7-�<
0 0 N 115' (R)
< d 1/2" d 1/210
3.2'
0.2 n
u u
L0
It
Pr) 32.6
0.1'
12.6 40.6'
0 LOT 5
0 >
C) BLOCK 23
M w
_j
COVERED CONCRETE J
A' Tl WALK
A Ix
20.0'
0.4' 1 STORY BRICK
RESIDENCE in
NO. 480 A 0
(2.0' EAVES) CONCRETE 0
CL Lo (o
cr_
LLI 0
nRIVE
0 JIK C-4
to
Lij
z
.... .... ..... - - 65.1' 20!0' '90
AC F4-1 CONCRETE -in
PAD PAD CONCRETE uj
<
n n
1.3' PAD
x j1 3.0' 0
C40 115' (R) 1/201 o
0
F_ c; 114.99' (M)
z to
< 1/2"
<
0
LOT 4
BLOCK 23
v o QENERAL NOTESi
62 1. ANGLES ARE SHOWN FOR THIS SURVEY
2.STRUCTURE NO. 480 SHOWN HEREON LIES %THIN FLOOD ZONE X AS BEST
ASSOCIATED SURVEYOR3 INC. DETERMINED FROM F.E.M.A. FLOOD MAPS PANEL NO. 1 DATEDO4-17�1989.
LAND & ENGINEERING SURVEYS 3.THIS IS A SURFACE SURVEY ONLY. THE EXTENT OF UNDERGROUND FOOTINGS,
Lu PIPES AND UTILITIES, IF ANY, NOT DETERMINED.
3846 BLANDING BOULEVARD 4.JURISDICTIONAL AND/OR ENVIRONMENTALLY SENSITIVE AREAS IF ANY, NOT
JACKSONVILLE, FLORIDA 32210 LOCATED BY THIS SURVEY.
904-771-6468 5.THIS SURVEY BASED ON LEGAL DESCRIPTIONS FURNISHED. THE PUBLIC
CERTIFICATE OF AUTHORIZATION NO. LB 0005488 RECORDS WERE NOT SEARCHED BY THIS SURVEYOR FOR EASEMENTS,l
0 s s v TITLE. COVENANTS, RESTRICTIONS, CLOSURES, TAKINGS OR ORDINANCES, ETC.
THERE COULD BE OTHER MATTERS OF RECORD THAT AFFECT THIS PARCEL
I HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY 6.UNLESS OTHERWISE STATED ALL IRON PIPES FOUND HAVE NO IDENTIFICATION.
DIRECT SUPERVISI D MEETS THE MINIMUM TECHNICAL GUY ANCHOR LEGENDIAMEVIATIONS (R) - RECORD
ON 1 -0
STANDARDS FOR LAN PSURVEYING RSUANJ TO CHAPTER
A Ct4 0 SET IRON PIPE OR REBAR MAKED P.C.= POINT OF CURVE (M)-MEASURED
6;� 6,�FLORID INIS7PATION E, TER 472, F.S. ASSOC. SURVEY " OR L.B. 5488 P.T.=POINT OF TANGENCY A - CENTRAL
FOUND IRON PIN OR PIPE C/L = CENTERLINE ANGLE
FOUND CONCRETE MONUMENT I.P.= IRON PIPE OR PIN L-ARC LENGTH
X CROSS CUT OR DRILL HOLE R/W - RIGHT OF WAY R- RADIUS
P.R.C. POINT OF REVERSE CURVE W - WIRE FENCE 0 WATER
BY:/CHARLES B. HKrCHVF' FLORIDA RTHICATE NO. 3771
BY:ICHARLES L. STARLpG FLORIDA/CERTIFICATE NO. 4579 p.C.C. POINT OF COMPOUND CU E10-0- WOOD FENCE METER
CTION L7
BY*. RAYMOND J. SCHAEFER FLORIDA CERTiFICATE NO. 6132 B.R.L BUILDING RESTRI NE CONC.- CONCRETE 0 = WELL
I(ORB) OFFICIAL RECORDS; BOOKIX—X-CHNNUNK FENCE * - STREET
JOB NO. 46304 DATE a-i' -2005 - RV, - OFFICIAL RECORDS VOLUMEIcU3 UTILITY POLE I LIGHT
1 0
L 1- = 20' DRAf7ER C.L.S. - ' _k TY —OU--OVERHEAD UTILITIES
LSCALE: J.E =JACKSONVILLE ELECTRIC AUTHORI
NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR AND MAPPER
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
-5826
INSPECTION PHONE LINE 247
Application Number . . . . . 06-00033560 Date 7/25/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . INSTALL IRR. SYSTEM
Application description . . . PLUMBING ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI HULIHAN TERRITORY
480 OCEAN BLVD. P.O. BOX 331268
JACKSONVILLE FL 32223 ATLANTIC BEACH FL 32233
(904) 285-8505
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . -
Permit Fee . . . . 45 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
---- ------------- ---------- ---------- ---------- ----------
Permit Fee Total 45 . 00 45 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 45 . 00 45 .00 .00 . 00
pERMIT IS AppROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
Disposals Urinals
Floor Drains Washing Machine
Lavatory Water
Sewer Water Heaters
Sprinkler System Other
Fees
Perniff Issuing Fee: $35.00
Total Fixtures: X$7.00 + $35.00
- - 7
'q 7�
-71
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
d, ATLAWIC BEACH,n 32233
INSpEcnoN PHONE LINE 247-5826
Application Number . . . . . 06-00033144 Date 6/05/06
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . REWIR SERVICE 200AMP/120V
Application description . . . ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI BARKOSKIE ELECTRICAL SERVICE,
480 OCEAN BLVD. INC.
JACKSONVILLE FL 32223 48 S . PENMAN ROAD
JAX BEACH FL 32250
(904) 246-4731
------------------------------------------------ ----------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 105 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 105 - 00 105 . 00 . 00 .00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 105 . 00 105 . 00 . 00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE Wfrfl ALL Crff OF ATLANnC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
CIT F ATLANTIC BEACH
RMIT AP
UILDING PLICATION
jf 1v
(Alterations& Additions)
0 Date:
Job Address:
Owner of Property:
Addre5s: ell'- 677 -6 3=-5 Telephone:
4- A )CZ6'
Lega�Description: Block Number: 2- Lot Number: Zoning District:
Contractor: Rs. pe-�)Ofx/ td. akT—State License Number: be,-.
Contractor Address: 350
Teleubone: al� 900 Fax: //54..
Describe proposed use and ork to be done:
_7A
Present use of land or building(s):
Valuation of proposed construction:
What are the dimensions of the added space. 15t5 feet x (9 feet(crthna, GL
Will the added area be heated and cooled? U ff New electrical or increase in service?
Add plumbing fixtures? ME��h , Add firepLe? 0 Add hea'ting/air conditioning?
Is approval of Homeowner's Association or other private entity required? If yes, please submit with this
application.
Will this project involve changes in elevation, site grade or any use of fill material, or the addition of 5% or more to
the original impervious area or the removal of any trees?
VNO. Applicant certifies that no change in site grade, impervious area or rill material will be used on this
project.
YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building
Permit,
NO. Applicant certifies that no trees will be removed for this project.
YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree
Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month.
Procedure: In order to expedite issuance of permits, please follow all steps and Provide all information as appropriat .
Incomplete applications may result In delay in issuance of permit.
STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please
contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have
Property Appraiser's Real Estate Number available.
STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction
topographical survey or grading plan is required. (If not required,written verification must be provided with this application.)
The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834
STEP 3. Submit Tree Removal Application if trees are to be removed or relocated.
STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if
owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic
Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826
800 Seminole Road -Atlantic Beach,Florida 32233-5445
Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atiantic-beach.fl.us
Page 2 Revised 8/04
In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being
performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner.
1. CurTent survey showing the property boundary with bearings and distances and the legal description.
2. Location of all structures,temporary and permanent,including setbacks,building height;number of stories and square footage. Identify
any existing structures and uses.
3. If required by the Department of Public Works,a pre-construction topographical survey.
4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies.
5. Impervious Surface area calculations: include driveways,sidewalks, patios and other Impervious Surfaces. Swimming pools
may be excluded from total Impervious Surface.
6. Other information as may be appropriate ual applications.
'*"-% , f
I hereby certify that all info7lation Ji ov witmh 7thni, a, plication is correct.
Signature of owner- Date�����
I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and
ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to
give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the
governing of construction or the pe c f construc* n of the property. I understand that the issuance of this permit is contingent upon the
above information being true an o ct that thi . s and supporting data have been or shall be provided as required.
Signature of Contractor- Date:
Address and contact information of person to receive all correspondence regarding this application(please print).
Name:
Mailing Address:
Telephone: Fax: E-Mail:
Sworn to and subscribed before me this A day of 20-0-SL.
State of Florida,County of Duval
Cynthia A Dy"
MY COMMISSION# DD259940 E)" "Personally knowv4nk��
1 October 2Z 2007
somXOTRUTROY,FAN*WAUa W6 Produced identification
Type of identification produced
AS TO CONTRACTOR:
Sworn to and subscribed before me this day V&a
of Aly aglt 20 Lai
State of Florida,County of Duval Notary's Signature: d (�9
am,a
Ointhici A D/"
MY COMMONION# DD259940 WM ersonally known
October A 2007
90NDEDrrW"FAMWUWXkW_ Produced identification
Type of identification Moduced bt LeA
DONNA L BUSSEY
800 Seminole Road -Atlantic Beach,Florida 32233-5445
my commisSiON#DD 412624
EXPIRES:March 30, hc e: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atiantic-beach.fLus
Revised 8/04
CITY OF ATLANTIC BEACH
FLOOD PLAIN DEVELOPMENT INFORMATION
Location: 40
Type of Development:
Flood Zone:,
Required Lowest Floor Elevation:
If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB
HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above
the base flood elevation established for that zone.
No final inspection will be made and no Certificate of Occupancy will be issued until the survey
is on file with the Building Department.
COMMENTS:..
Applicant Acknowledgement: I understand that the issuance of this permit is contingent upon
the above information being correct and a he plans and supporting data have been or shall be
provided as required. I agreeAco ly ith 11 applicable provisions of Ordinance No. 25-7-11
p �i 11)
and all other laws or ord afctin the- d development.
Applicant's Signatur at
Department Use:
Required lowest floor elevation:
As built lowest floor elevation:
Survey filed with Building Department:
Building Department Representative
Revised 1/17/03
CITY OF ATLANTIC BEACH
BUILDING PERMIT APPLICATION CHECKLIST
(For Alterations/Additions)
APPLICATION CHECKLIST/REQUIRED SUBMITTALS
1. Building Application Form
2. Two (2) complete sets of plans including detailed site plan
(If site grade, impervious surface or fill material is being changed,
four(4) sets are required)
/3" Recent survey (2)
tV4. Owner/Builder Affidavit(required when owner acts as contractor) (2)
15. Energy Sheets (2)
6. Construction Site Management Plan(2)
:V7. Recorded Notice of Commencement(2)
P8. Tree Removal Application if trees are to be removed or relocated (3)
VIV
SCHEDULED INSPECTIONS
Requests for inspections are taken from 8:00 a.m. to 5:00 p.m. Monday through Friday at 247-5826. Requests
can be scheduled after hours by leaving a message on the voice mail system. Inspections are made the
following working day; please specify a.m. or p.m. inspection. When calling in an inspection, please have the
permit number,job location and type of inspection needed. Inspections are scheduled as follows:
I. Footing
2. Under slab plumbing/sewcr/electric
3. Slab
4. Cover up: Framing, Rough Electric, Mechanical and Plumbing.
(This is different from other jurisdictions)
5. Insulation
6. Final Inspection(includes drainage,trees, landscape and site inspection)
Finished floor elevation survey required prior to issuance of Certificate of Occupancy.
BUILDING CARD MUST BE POSTED OR NO INSPECTIONS WILL BE MADE.
Concrete cannot be poured and work cannot be covered up until building card is SIGNED by the inspector.
You may be required to uncover any work that has not been inspected. It is the responsibility of the
BUILDER/CONTRACTOR to post the building card. A fee of$35.00 is charged for all re-inspections.
NOTE: This application may be subject to covenants and restrictions for the permitted property. The
enforcement of the covenants and restrictions are the responsibility of the homeowner's association.
800 Seminole Road -Atlantic Beach,Florida 32233-5445
Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.cLatiantic-beach.fl.us
Page 1 Revised 8/04
ILD
NOTICE
OF
ADDITIONS or CORRECTIONS
DO NOT REMOVE
JOB ADDRESS DATE
!6S2 Ofc—&A- 7:�. 1
THIS JOB HAS NOT BEEN COMPLETED
The following additions or corrections shall be made
before the job will be accept d.
67 kfft��
_L��$35.00 REINSPECT FEE NO CHARGE
It is unlawful for any Carpenter, Contractor, Builder or other
persons, to cover to cause to be covered, any part of the
work with flooring, lath, earth or other material, until the
proper inspector has had ample time to approve the
installation.
After additions or corrections have BLDG
been made contact the Building Dept. ELEC
at 247-5826 for an inspection. Office MECH
hours are Monday through Friday PLMG
8:00 a.m.to 5-00 P.M.
NOTICE
I D OF
141 AWITIqlI* ' CORRECTIONS
Ck# "DO NOT REMOVE
JOB ADDRESS DATE
THIS JOB HAS NOT BEEN COMPLETED
The following additions or corrections shall be made
before the job will be accepted.
---------- iziz U-ir-
jj��A 6) tAAA-5,s t o!�j
1A <-at"e CCAU k2
;L
Anpr�aj:� ILAUT I q
op&*— psi
Lk
C-7 aq&6"Q )i4v — Mis's
On
Isn
C4!D—
Voo-$35.00 REINSPW FEE NOCHARGE-6�v-_
It is unlawful for any Carpe4r, Cgintractor, Builder or other
persons, to cover to- se to be7covjV, any part of the
work with floory%Cat, ej*t or othili4ftaterial, until the
proper inspect&*� j had time to approve the
installation. TWF
After additions or corrections, e BLDG
been made contact the Building ELEC
at 247-5826 for an inspection. Office MECH
hours are Monday through Friday PLMG
8:00 a.m.to 5:00 P.M.
WATER IMPACT FEE WORKSHEET
ADDRESS:
DRAINAGE
FiXTURE UNIT
FIXTURE TYPE VALUE AS LOAD FIXTURES UNITS
Automatic clothes washers,comrnercial 3
Automatic clothes washers, residential 2
Bathroom group consisting of water closet lavatory,
Bidet, a I nd bathtub or shower 6 61
Bathtub(with or without overhead shower or whidpool Z-
attachments) 2
Bidet 2
Combination sink and tray 2
Dental lavatory I
Dishwashing machine,domestic 2
Drinking fountainflcemaker-
Floor drains 2
Hose bib I
Kitchen sink, domestic 2
Kitchen sink, dornesbc with food waste grinder and/or
dishwasher 2
Laundry tray(1 or 2 compartments) 2
-Lavatory I
Shower compartment,domestic 2
Sink 2
Urinal 4
-Urinal, 1 gallon per flush or less 2
Wash sink (circular or multiple)each set of faucets 2
Water closeL flushometer tank, publicor private 4
Water closet,private installation 4
Water closet public installation 6
TOTAL NUMBER OF UNITS= I el
MULTIPLIED X 20 u
TOTAL$ 3 VC
CITY OF ATLANTIC BEACH Cc:
D. F
BUILDING / ZONING DEPARTMENT
Hig ins
800 Seminole Road S. Doerr
P)
Atlantic Beach,Florida 32233
(904)247-5800
(904)247-5845 Fax
www.coab.us
PLAN REVIEW COMMENTS
Permit Application # �.5- - '=5 1,§-L W
Property Address: '�5z- VA
Applicant:
Project: JA A 12 b Xf /-7
This permit application has been:
1:1 Approved
ED*" Reviewed and the following items need attention:
F(3 C- t t, -,--k0Qq - Ck,\A±��
Ez- 1�-�Tfa -5
I'Alew CC)ov-- V)V&5 au�- �A4 Ve Tzi e 42 \1 I
( C- In k-( wttto Qda'q—
�s 0 le—, �k 0 PtS?jo
1.5 (:ba- 2-(Sm) L C��C- cLto!:2� 2,00'<4 iz:-ec—
Qn±C6 rdbC 0 t'(X-e-d- LA-4 A C�-Lk)� rx c6--ts
Please re-submit your application when these items have been completed.
Reviewed By: 4L Date:
Date Contractor Notified:
Consulting Engineers
Frank J. Holas, P.E.
-4 ftD 0 President
f rank j holas and associates, inc
engineering support to the construction industry
4�
November 15, 2005
Building Department City of Atlantic Beach VY
800 Seminole Road
Atlantic i a
Reference: Porcelli Residence
480 Ocean Blvd.
W, S A-T?(Iz 104-C
Atlantic Beach, Florida
Attention: Building Officials, Building Inspectors, Plan Reviewers
And other interested parties
According to the construction drawings submitted, reference was made to the Florida
Building Code, 2001 Edition shall now be in accordance with the 2004 Edition of the
Florida Building Code. This project is located in a Wind Bome Debris Region. Window
protection shall be in accordance with Chapter 1600 for protection of openings and not
1606.1.4 as shown on the drawings. Please make note of these substitutions. Thank you
for your consideration.
Should you have any further questions please contact me directly at (904) 285-5868.
Sincerely,
Dale Caswell, Desig�n�Associate
bu
5201 Atlantic Boulevard, #119 - Jacksonville, Florida 32207 * Office (904) 396-3318 Fax (904) 396-1087
Consulting Engineers
Frank J. Holas, P.E.
President
f rank j holas and associates, inc
engineering support to the construction industry
November 15, 2005
Building Department City of Atlantic Beach
800 Seminole Road
Atlantic Beach, Florida 32233
Reference: Porcelli Residence
480 Ocean Blvd.
Atlantic Beach, Florida
T pect rs, Din Revie e s
IIASF�M I IM 1�'�IeIV'V'V'I
A++en."Llon: Bu;IA;.-.g Ofricials, Qu
And other interested parties
According to the construction drawings submitted, reference was made to the Florida
Building Code, 2001 Edition shall now be in accordance with the 2004 Edition of the
Florida Building Code. This project is located in a Wind Borne Debris Region. Window
protection shall be in accordance with Chapter 1600 for protection of openings and not
1606.1.4 as shown on the drawings. Please make note of these substitutions. Thank you
for your consideration.
Should you have any ftu-ther questions please contact me directly at (904) 285-5868.
Sincerely,
Dale aswell, Design Associate
5201 Atlantic Boulevard, #119 Jacksonville, Florida 32207 - Office (904) 396-3318 9 Fax (904) 396-1087
MAP SHOWING BOUNDARY SURVEY OF
LOT 5 BLOCK 23 ACCORDING TO THE PLAT OF
SUBDEVESCON "A" ATLANTEC BEACH
AS RECORDED IN PLAT BOOK 5 , PAGE(S) 69 OF THE CURRENT
CERTIFIED TO: PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
ARTHUR PROCELLI,
STEWART TITLE GUARANTY COMPANY, WATSON & OSBORNE TITLE SERVICES, INC.
AND OCEANSIDE BANK.
FIFYH SIrRr= r= "r
40' R/W
3/4"
LOT 6
BLOCK 23
ri=Zl
H
Llj R 114.88- (M)
c;ail N
d 15' (R)
< 1/2"
0.2' 1/2"
12'
0 loo
>
32.0' 'bc'
�e 0.3
0 110' 40.6'
() c; N LOT 5
Ill 0 .0,
... ... ... ... BLOCK 23
CON
< COVERED WCRETE w
A WALK
CL 0.4, 1 STORY BRICK 20.0'
sm x RESIDENCE
Ld %-.1
5. NO. 480
< QA (2.0- EAVES)
cn; CONCRETE 0 g 0
0 x DRIVE L0 (o
d2lb
0
T 5
CK 23
CONCRETE
WALK
20_0
CONCRETE
DRIVE
ul
LLI
C3
65.1'
0.0.
0
AC CONCRETE 2
2010' 1po
LL) t.: PAD PAD CONCRETE
n n PAD 011. ui
m rn-n-J
x
L) U
115' (R) 112"
z 114.99- (M) 0
< 1/2"
-j
LOT 4
BLOCK 23
GENERAL NOTES,
I. ANGLES ARE SHOWN FOR THIS SURVEY
2.STRUCTURE No. 480 SHOWN HEREON UES WITHIN FLOW ZONE X AS BEST
As30CIATED 3URVEYOR3 INC. DETERMINED FROM F.E.M.A. FLOOD MAPS PANEL NO. I DATED D41-17-1989.
w LAND & ENGINEERING SURVEYS 3.THIS IS A SURFACE SURVEY ONLY. THE EXTENT OF UNDERGROUND FOOTINGS,
PIPES AND UTILITIES, IF ANY, NOT DETERMINED.
3846 BLANDING BOULEVARD 4.JURISDIC71ONAL AND/OR ENVIRONMENTALLY SENSITIVE AREAS IF ANY, NOT
s JACKSONVILLE, FLORIDA 32210 LOCATED BY THIS SURVEY.
0 904-771-6468 5.THIS SURVEY BASED ON LEGAL DESCRIPTIONS FURNISHED. THE PUBLIC
0 CERTIFICATE OF AUTHORIZATION NO. LB 0005488 RECORDS WERE NOT SEARCHED BY THIS SURVEYOR FOR EASEMENTS.
S V TITLE. COVENANTS, RESTRICTIONS, CLOSURES, TAKINGS OR ORDINANCES, ETC.
THERE COULD BE OTHER MATTERS OF RECORD THAT AFFECT THIS PARCEL
I HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY 6.UNLESS OTHERWISE STATED ALL IRON PIPES FOUND HAVE NO IDENTIFICATION.
DIRECT SUPERVISION A D MEETS THE MINIMUM TECHNICAL
STANDARDS FOR LAN SURVEYING P14RSU 0 CHAPTER -0 - GUY ANCHOR LFIQENDIA�KVIIATIONS (R) - RECORD
F Y�AN T 0 -SET RON PIPE OR RE13AR MARKED P.C.= POINT OF CURVE (M)-MEASURED
617G16, FLORIDA INIS T!O N C TER 472, F.S. ASSOC. SURVEY " OR L.B. 54M P.T.-POINT OF TANGENCY A - CENTRAL
FOUND IRON PIN OR PIPE C/L - CENTERUNE MOLE
7E
N - FOUND CONCRETE MONUMENT I.P.- IRON PIPE OR PIN L-ARC LENGTH
BY: CHARLES B. HATCH FLORIDA VRTIFICATE NO. 3771 X - CROSS CUT OR DRILL HOLE RIW - RIGHT OF WAY R- RADIUS
I P.R.C.- POINT OF REVERSE CURVE W - WIRE FENCE 0 - WATER
BY: CHARLES L. STARLift FLORIDAAERTIFICATE NO. 4579 P.C.C.- POINT OF COMPOUND CURVE G-El- WOOD FENCE METER
BY: RAYMOND J. SCHAEFER FLORiDA CERTIFICATE NO. 6132 B.R.L - BUILDING RESTRICTION LINE CONC.- CONCRETE WELL
Fs'�CJOB NO. 46304 DATE 07-22-2005 l(ORB) = OFFICIAL RECORDS BOOK X-X-CHAINLINK FENCE STREET
OB (ORV) - OFFICIAL RECORDS VOLUMElcQ-3 - UTILITY POLE LIGHT
ALE-:0 - 1 20' DRAFTER C.L.S. J.EA =JACKSONVILLE ELECTRIC AUTHORITY -OU--OVERHEAD UTILITIES
NOT VAUD WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR AND MAPPER
Cc:
CITY OF ATLANTIC BEACH D.
sl�,\
BUILDING / ZONING DEPARTMENT Higgins
800 Seminole Road
Atlantic Beach,Florida 32233
(904)247-5800
(904)247-5845 Fax
wwwxoab.us
PLAN REVIEW COMMENTS
Permit Application #
Property Address: 48D-- D(-,eO-f) rzo!?)Ivd--.
Applicant: enL-,P7( kx,l 11 V�-
Project: a J& 4rql �im�
This permit application has been:
Approved
�R Reviewed and the following he eed attention:
evie�wed a�ndthe�foll wing
Please re-submit your application when these items have been completed.
Reviewed By: Date:
Date Contractor Notified:
BP200IO1 CITY OF ATLANTIC BEACH 2/21/06
Application Inquiry 16:27 : 10
Application number . . . . . : 05 00031564
Application status, date . . : PERMIT ISSUED 1/11/06
Property . . . . . . . . . . L;-�f8O )DCEAN BLVD
RE number. . . . . . . . . . . t 1�3-0000- -
NCR OLD ACCOUNT NUMBERS. . . : ABO1102
Zoning * * * * ' * * ' * * * : TBU TO BE UPDATED
Application type . . . . . . : RAAR RESIDENTIAL ADD/RENOVATE/ALTER
Application date . . . . . . : 11/02/05
Tenant nbr, name . . . . . . : ADD 2ND FLR OVER 1ST FLR
Master plan nbr, revwd by : KJC
Estimated valuation . . : 190000
Total square footage . . . . : 0
Public building . . . . . . : NO
Work description, qty . . . :
Pin number . . . . . . . . . : 091256
Press Enter to continue.
F3=Bxit F5=Land inq F7=Appl names F8=Tracking inq F9=Bond inquiry
Flo=Fees Fll=Receipts F12=Cancel F13=Val calcs F24=More keys
FORM 600A�-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: OP167605 Builder: R.S.PENNINGTON
Address: 480 OCEAN BLVD Permitting Office:
City, State: ATLANTIC BCH, FL Permit Number:
Owner PORCELLI Jurisdiction Number:
Climate Zone: North
1. New construction or existing Addition — 12, Cooling systems
2. Single family or multi-family Single family — a. Central Unit Cap:42.0 kBtu/hr
3. Number of units,if multi-family SEE& 12.00
4. Number of Bedrooms 4 b.N/A
5. Is this a worst caw? Yes
6. Conditioned floor area(W) 1676 ft2 c.N/A
7. Glass area&type Single Paw Double Pane —
a. Clear glass,default Wactor 0.0 ft2 408.0 ft2 - 13. Heating systems
b.Default tint 0.0 W 0.0 ftz — a. Electric Heat Pump Cap.42.0 kBtu/hr
c. Labeled U or SHGC 0.0 ft2 0.0 fl2 HSPF:7.80
8. Floor types b.N/A
a. Slab-On-Gradc Edge Insulation R=0.0,26.0(p)ft
b.N/A c. N/A
c. N/A
9. Wall types 14. Hot water system
a. Fnune,Wood,Exterior R=19.0,1239.0 ft2 a. Electric Resistance Cap:60.0 gallons
b.NYA EF:0.90
c. NIA b.N/A
d.NIA
e. N/A c. Conservation credits
10. Ceiling types (HR-Heat rwovery,Solar
a. Under Attic R=30.0,1484.0 ft2 DHP-Dedicated heat pump)
b. Single Assembly R=19.0, 192.0 fe 15. HVAC credits PT,CF,
c. N/A (CF-Ceiling fan,CV-Cross ventilation,
11. Ducts HF-Whole house fan,
a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0, 182.0 ft PT-Programmable Thermostat,
b.N/A MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.24 Total as-built points: 29305
Total base points: 29556 PASS
I hereby certify that the plans and specifications covered Review of the plans and ot
by this calculation are in co)mpliance with the Florida specifications covered by this
Energy Code. calculation indicates compliance
PREPARED BY: with the Florida Energy Code.
Before construction is completed
DATE: /r)-/,- 't-- this building will be inspected for
I hereby certify that this building, as designed, is in compliance with Section 563.908
compliance with the Florida Energy Code. Florida Statutes. WS
OWNERIAGENT: BUILDING OFFICIAL:
DATE: DATE:
EnergyGaugee(Version: FLRCSB v3.30)
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 480 OCEAN BLVD,ATLANTIC BCH,FL, PERMIT
BASE AS-BUILT
GLASS TYPES
18 X Conditioned X BSPM Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points
.18 1676.0 20.04 OW.7 Double,Clear E 1.5 10.0 30.0 42-06 0.98 1234.5
Double,Clear N 1.5 12.0 44.0 19.20 0.99 837.3
Double,Clear E 1.5 7.0 30.0 42.06 0.94 1184.1
Double,Clear E 1.5 8.0 24.0 42.06 0.96 966.7
Double,Clear S 1,5 8.0 24.0 35.87 0.92 794.8
Double,Clear S 12.0 9.0 66.0 35.87 0.48 1145.9
Double,Clear S 12.0 6.0 30.0 35.87 0.45 485.4
Double,Clear W 1.5 7.0 20.0 38.62 0.94 723.4
Double,Clear W 1.5 6.0 16.0 38.52 0.91 563.0
Double,Clear w 1.5 5.0 6.0 38.52 0.88 202.4
Double,Clear N 1.5 7.0 30.0 19.20 0.96 650.1
Double,Clear E 14.0 9.0 44.0 42.06 0.43 788.9
Double,Clear N 13.0 9.0 44.0 19.20 0.68 556.7
As-SWIt Total: 408.0 10033.0
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 0.0 0.00 0.0 Frame,Wood,Exterior 19.0 1239.0 0.90 1115.1
Exterior 1239.0 1.70 2106.3
Base Total: 1239.0 2106.3 As-Built Total; 1239.0 1115.1
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0
Exterior 0.0 0.00 0.0
Bese Total: 0.0 0.0 As-BuIlt Total: 0.0 0.0
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM= Points
Under Attic 1676.0 1.73 2899.5 Under Attic 30.0 1484.0 1.73 X 1.00 2567.3
Single Assembly 19.0 192.0 5.64 X 1.00 1082.9
Sam Total: 1676.0 2899.5 As-Built Total: 167&0 36W.2
FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM = Points
Slab 26.0(p) -3-7.0 -962.0 Slab-On-Grade Edge Insulation 0.0 26.0(p) -41.20 -1071.2
Raised 0.0 0.00 0.0 1
Bass Total: -962.0 . As-Built Total: 26.0 -1071.2
EnergyGaugefl)DCA Form 60OA-2001 EnergyGauge&FlaRES'2001 FLRCSB 0.30
FORM MA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 480 OCEAN BLVD,ATLANTIC BCH, FL, PERMIT
BASE AS-BUILT
INFILTRATION Area X 8SPM Points Area X SPM = Points
1676.0 10-21 17112.0 1676.0 10.21 17112.0
Summer Bass Points: 27201.4 Summer As-Built Points: 30839.0
Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling
Points Multiplier, Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
30839.0 1,000 (1.090xi.147xl.00) 0.284 0.902 9896.8
27201.4 0.4266 11604.1 30839.0 1.00 1.250 0.284 0.902 9896.8
EnergyGaugeT*DCA Form 60OA-2001 EnergyGaugeWlaRES'2001 FLRCSB v3.30
FORM MA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 480 OCEAN BLVD,ATLANTIC BCH,FL, PERMIT
FGLASS TYPES BASE AS-BUILT
.18 X Conditioned X BWPM Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Poin]
.18 1676.0 12.74 3843.4 Double,Clear E 1.5 10.0 30.0 111.79 1.01 571.0
Double,Clear N 1.5 12.0 44.0 24,58 1.00 1081.2
Double,Clear E 1.5 7.0 30.0 1S.79 1.03 578.8
Double,Clear E 1.5 8.0 24.0 18.79 1.02 460.0
Double,Clear S 1.6 8.0 24.0 13-30 1.04 332.2
Double,Clear S 12.0 9.0 66.0 13.30 3.15 2764.0
Double,Clear S 12.0 6.0 30.0 13.30 3.51 1398.4
Double,Clear w 1.5 7.0 20.0 20-73 1.02 421.4
Double,Clear w 1.5 6.0 16.0 20.73 1.02 339.4
Double,Clear W 1.5 5.0 6.0 20-73 1.03 128.7
Double,Clear N 1.5 7.0 30.0 24.68 1.00 738.5
Double,Clear E 14.0 9.0 44.0 18.79 1.40 1157.1
Double,Clear N 13.0 9.0 44.0 24.58 1.02 1105.5
As-Built Total: 4N.0 11076.0
WALL TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Adjacent 0.0 0.00 0.0 Frame,Wood,Exterior 19.0 1239.0 2.20 2725.8
Exterior 1239.0 3.70 45".3
Bass Total: 1239.0 4584.3 As-Built Total: 1239.0 2726.8
DOOR TYPES Area X BWPM Points Type Area X WPM Points
Adjacent 0.0 0.00 0.0
Exterior 0.0 0.00 0.0
Base Total: 0.0 0.0 As-Built Total: 0.0 0.0
CEILING TYPES Area X 8WPM = Points Type R-Value Area X WPM X WCM= Points
Under Attic 1676.0 2.05 3435.8 Under Attic 30.0 1484.0 2.05 X 1.00 3042.2
Single Assembly 19.0 192.0 1.86 X 1.00 357.1
Sam Total: 1676.0 3435.8 As-Bulft Total: 1676.0 3M.3
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM z Points
Slab 26.0(p) 8.9 231.4 Slab-On-Grade Edge insulation 0.0 26.0(p) 18.80 488.8
Raised 0.0 0.00 0.0
Base Total: 231.4 1 As-Builtrotal: 26.0 488.8
EnerqyGaupS DCA Form 60GA-2001 EnergyGaugeWFIaRES'2001 FLRCSB v3.30
FORM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 480 OCEAN BLVD,ATLANTIC BCH,FL, PERMIT#:
BASE AS-BUILT
INFILTRATION Area X BWPM = Points Area X WPM = Points
1676.0 -0.59 -M.8 1676.0 -0.69 -9".8
Winter Base Points: 11106.1 Winter As-Built Points: 16701.1
TotalWinter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
16701.1 1,000 (1.069 x 1.169 x 1.00) 0.437 0.950 SM.0
11106.1 0.6274 6967.9 16701.1 1.00 1.250 0.437 0.950 8668.0
EnergyGauqe7m DCA Form 60OA-2001 EnergyGaugeWlaRES'2001 FLRCSS v3.30
FORM 60OA-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: 480 OCEAN BLVD,ATLANTIC BCH,FL, PERMIT#:
BASE AS-BUILT
WATER HEATING
Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
4 2746.00 10984.0 60.0 0.90 4 1.00 2684.98 1.00 10739.9
A843ullt Total: 10739.9
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling Heating + Hot Water Total Cooling + Heating + Hot Water Total
Points Points Points Points Points Points Points Points
11604 6968 10984 295.56 r 9897 8668 10740 29305
E PASS.J
S
EnergyGauqeTO DCA Form 60GA-2001 EnergyGaugeWFlaRES'2001 FLRCSB v3.30
FORM 60OX-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
FADDRESS' 480 OCEAN BLVD,ATLANTIC BCH,FL, PERMIT
OA-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE
Exterior Windows&Doors 606AABCAJ Maximum:.3 cfrn/sq.ft.window area;.5 cfm/sq.ft.door area.
Exlerlor&Adjacent Walls 606.1 ABC.1.2.1 Caulk,gasket,weatherstrip or seal between.windows/doors&frames,surrounding wall;
foundation&wall sole or sill plate;joints between exterior wall panels at comers;utility
penetrations;between wall panels&top/bottom plates;between wells and floor.
EXCEPTION:Frame wails where a continuous infiltration barrier is installed that extends
from,and is sealed to,the foundation to the top plate.
Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members.
EXCEPTION:Frame floors where a continuous Infiltration barrier is installed that is sealed
to the perimeter,penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between wails&ceilings;penetrations of ceiling plane of top floor,around shafts,chases,
soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate;
attic access.EXCEPTION:Frame ceilings where a continuous infiftrabon barrier is
installed that is sealed at the perimeter,at penetrations.and seems.
Recessed Lighting Fixtures 606.IABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a
sealed box with 1/2"clearance&3"from Insulation;or Type IC rated with<2.0 cfm from
conditioned space,tested.
Mufti-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded all residences.)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit
breaker(electric)or cutoff(gas)must be provided.External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-cornmercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
efficiency of 78%.
Showerheads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and installed in rdance with the criteria of Section 610.
Ducts in unconditioned attics:R-6 min.Insulation. '
HVAC Controls 607A Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min.R-1 9.Common wails-Frame R-1 I or CBS R-3 both sides.
Common coiling&floors R-1 1.
EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugoOD/FlaRES'2001 FLRCSB v3.30
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* 82.5
The higher the score,the more efficient the home.
PORCELLI, 480 OCEAN BLVD, ATLANTIC BCH, FL,
1. New construction or existing Addition - 12. Cooling system
2. Single family or multi-family Single family - a. Central Unit Cap:42.0 kBuAir
3. Number of units,if multi-family I - SEER: 12.00
4. Number of Bedrooms 4 b.N/A
5. Is this a worst case? Yes
6. Conditioned floor area(ft) 1676 ft2 c. N/A
7. Glass am&type Single Pane Double Pane
a. Clear-single pane 0.0 ft2 408.0 ft2 13. Heating systems
b.Clear-double pane 0.0 ft2 0.0 ft2 a. Electric Heat Pump Cap:42.0 kBtu/hr
c. Tint/other SHGC-single paw 0.0 ft2 0.0 ft2 HSPF:7.80
d.Tint/otber SHGC-double pane b.N/A
8. Floor type
a. Slab-On-Grade Edge Insulation R=0.0,26.0(p)ft c. N/A
b.N/A
c.N/A 14. Hot water systems
9. wan types a. Electric Resistance Cap:60.0 gallons
a. Frame,Wood,Exterior R=19.0,1239.0 R2 EF:0.90
b.N/A b.N/A
c. N/A
d.N/A c. Conservation credits
e. N/A (HR-Heat recovery,Solar
10. Coiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0,1484.0 ft2 15. HVAC credits PT,CF,
b. Single Assembly R=19.0,192.0 ft2 (CF-Ceiling fW4 CV-Cross ventilation,
c.N/A HF-Whole house fan,
11. Ducts PT-Programmable Thermosta4
a. Sup:Unc. Ret:Unc. AM Garage Sup.R=6.0,182.0 ft MZ-C-Multizone cooling,
b.N/A MZ-H-Multizom heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed(or exceeded) -tto Sr
in this home before final inspection.Otherwise,a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*NOTE. The home's estimated energyperformance score is only available through the FLAIRES computer program.
This is pe!a Building Energy Rating.Ifyour score is 80 or greater(or 86for a US EPAIDOE EnergyStar"4designation),
your home may qual6for energy efficiency mortgage(EEAV incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at wwwfisec.uc
f edufor
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction,
contact the Department of Community Affai;gWSyW4WekW.ersion:FLRCSB v3.30)
Job:
Project Summary Claim: Oct 06,2005
Entire House By:
MONICA BACCA
4891 TIMLIQUANA ROAD,JACKSONVILLE,FL 32210 Phone:904-737-5499 Fax:904-779-7098 Email:mbjageCearthlink.not
Project Information
For: PORCELLI RESIDENCE
480 OCEAN BLVD,ATLANTIC BCH, FL
Notes:
Design Information
Weather: Jacksonville, Cecil Field NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 34 OF Outside db 95 OF
Inside db 70 OF Inside db 75 OF
Design TD 36 OF Design TD 20 OF
Daily range M
Relative umidity so %
Moisture difference 40 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 22559 Btuh Structure 17555 Btuh
Ducts 5409 cfm Ducts 7253 Btuh
Central vent(I 10 cfm) 4331 Btuh Central vent(110 cft-n) 2406 Btuh
Humidification 0 Btuh Slower 0 Btuh
Piping 0 Btuh
Equipment load 32299 Btuh Use manufacturer's data n
Ratelswing multiplier 1.00
Infiltration Equipment sensible load 27214 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2975 Btuh
Ducts 1262 Btuh
H"ting Cooling Central vent(110 cfm) 2999 Btuh
Area(ft2) 1618 1676 Equipment latent load 7236 Btuh
Volume(ft3) 15093 15093
Air changes/hour 0.38 0.20 Equipment total load 34450 Btuh
Equiv.AVF(cfm) 96 50 Req.total capacity at 0.70 SHR 3.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
Coil
Efficiency 0 HSPF Efficiency 0 EER
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh @ 470F Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1022 cfm Actual air flow 1022 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.041 dm/Btuh
Static pressure 0.00 in H20 Static pressure 0.00 in H20
Space thermostat Load sensible heat ratio 0.79
fW&ft1k values have been manually ovwrkkftn
Printout certified by ACCA to meet all requirements of Manuel J Sth Ed.
'VV"Q"t�C]kft Right-Sulte Residential 6.0.02 RSR24642 2005-Oct-06 19:10:27
AZK C:\My DocumetsWrightsoft HVAC\EIP167605.rrp Calc-MJ8 Orientation=N Page I
AED Assessment Job:
Date: Oct 06,2006
Entire House By:
MONICA BACCA
4891 TIMUQUANA ROAD,JACKSONViLLE,Fl.32210 Phone:9134-737-5499 Fax:9D4-779-7098 Email:mbjagsQearthlink.net
Project Information
For: PORCELLI RESIDENCE
480 OCEAN BLVD,ATLANTIC BCH, FL
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville, Cecil Field NAS, FL, US Indoor temperature(OF) 70 75
Elevation: 82 ft Design TD(OF) 36 20
Latitude: 30ON Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 9.7 40.3
Dry bulb(OF) 34 95 Infiltration:
Daily range�OF) - 20 ( M Method Simplified
Wet bulb(0 ) - 76 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Test for Adequate Exposure Diversity
Hourly Glazing Load
14,000-
12,000--
10,000--
8,000--
6,000-
4,000--
2,000--
0 1 4
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Hourly .0' Average oo' AED limit
Maximum hourly glazing load exceeds average by 18.8%.
House has adequate exposure diversity(AED), based on AED limit of 30%.
AED excursion: 0 Btuh
AMVVr-10Ht&C)ift Right-Sulte Residential 6.0.02 RSR24642 2005-Oct-06 19:10:27
CAMy Documents%Wrightsaft HVAC\BP 1 67605.rrp Calc-MJ8 Orientation-N Page 1
Right-J Worksheet Job:
Date: Oct 05,2005
Entire House By:
MONICA BACCA
4891 TIMLIQUANA ROAD,JACKSONVILLE,FL 32210 Phone:904-737-5499 Fax:904-779-7098 Email:mbjags@earthlink.net
I Room name Entire House DR
2 Exposed wall 183.0 ft 26.0 It
3 Ceiling height 9.0 ft 9.0 It heaVcool
4 Room dimensions 192.0 111 12.0 x 16.0 It
5 Room area 1677.0 ft2
Ty Construction U-value Or HTM Area (" Load Area (M Load
number (Stuh/ft2--F) —(8 or perimeter (ft) ( ) I or perimeter (ft) (Btuh)
Heat Cool Gross NIP/S Heat cool Gross NIP/S Heat Cool
X2
56Z
C 16C-30al 0.032 1.15 1�44 1485 1486 1711 2138 0 0 0
NJ
t��wow WVR��40�aft
I wfto 406mo r:A MW 0*10"Ww f to�:: 92 4498 0 192 26 1271 0
F '2*-'tPhl 1.358 - 48.89 0,00 192:iil,, 'r,," 'i1l'l0 i .: �, c
il i 5, : 1 �ii�� 1 yml�j! P� !:i ��i
ii � �:i:::�ifto I V., 2. '1 4N! 11
WOM! '14 0; :L�i i'WW"
q 4
"R
4 aM A
Ni
OAM
"'A "�"'0'z-1PN""l"' -A
W
4 '10i
e�;iijii Wig A n, I I'll
P,
W 0
$00
Lu 004--- M F"T MR,
'R9 61-
Mum
01,
4" C A,%
R,
&
N
N
100,t '0 V4 t: Wk
� 'N
VN PM, P MEE W4,'�O-
016 t
ii iwi-�""'A ii Oil
M REAM 5"-
N RE
A
MWROP:i�� i '�aIM:i,,".,- k
"."W" �51
M"A
2*6
01 �"R�"5' am 221VOk W 2
Aw 101
MNO EVA
ell Q'IN
0
"P
�:T
W"
K
0: 0514 &P.
ga
6 c)AED excursion 0 0
Envelope loi 18785 12211 3668 1859
12 a) Infiltration 3774 1104 536 157
b) Room ventilation 0 0 0 0
13 Internal gains: occupants Q 230 8 1840 2 460
Appliances(M 1200 2 2400 0 a
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 22559 17555 4204 2476
15 Duct bads 24%, 41%. �5409, 7253 1 24%, 41% 10081 10231
Total room load 27968 24808 5212 3499
r Air required(cfm) 1 10221 10221 1 1911 14]4
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
Right-Suite Residential 6.0.02 RSR246542 2005-Oct-06 19:10:28
C:\My Documeryts\Wrightsoft HVAC\BP167605.rrp Calc-We Orientation=N Page I
Right-J Worksheet Job:
Entire House Date: Oct 05,2005
MONICA BACCA By:
4891 TIMUQUANA ROAD,JACKSONVILLE,FL 32210 Phone:904-737-5499 Fax:904-779-7098 Email:mbjagsQearthlink.not
I Room name BRI/BIRMT/FY MBR/MBTH
2 Exposed wall 66.0 it 49.0 ft
3 Ceiling height 9.0 It heaticool 9.0 ft heat/cool
4 Room dimensions 13.0 x 38.0 it 19.0 x 29.0 it
5 Room area 494.0 1? 551.0 ft2
Ty Construction U-value Or HTM Area (fM Load Area (" Load
number (stuh/i (Stu or perimeter (it) ( h) or WMeter (ft) ( h)
Cool Gross N/Pi Heat Cool Gross N/P/S Heat Cool
"N gi 11
C 16C-30al 0.032 1.15 1.44 494 494 569 711 551 551 835 793
A
d,
F 22A-" 1.358 48.89 0.00 0 68 3227 0 0 0 0 0
A
0 h'-N-M0111', Ir Ift 005 W ��j'g
'ki vmmm WNW 999wM mift, 44 It I"v','tog"kiwO&
"IT-1, 014-1111 0-0 ON'.N 1,0il
-10
1 d
INV Al
Qp�W rAwKlir 4'r.
Z'
N,r4 g
'RAV N?
0 d d' '�:i
t
9w gddfiDN F�i' i:�q:� d!!
::i
Vl'2 AN-d MW=
rH�
?,6
d d�
-'r ffF7
wil kj M g"R"4 ft,
,Mili
RE
wAr : ,��', , 0 1 , Q ig"'WM t0@09 5, 1"01 ftWil NOR""Aw EAW&
;: rdi
Azir �t�!4d NIf
lirNN��'.Wizim'_0 ir, d rid:
U., 42NIRM 4111," WdW vl"�ddli
Ag
g_j
N ld A r;"
l" ZY �94ll jn
l did
wl I "l, 2N El
rid; ,i
4i I"
QRF�d
WO Ogg 054, M 404'g: IW 0
WIN N"MAR Pip,
k
0 d, 1.20"'A ft�
iftdrdd�!:!: 'Y5 rAd: zi #L
0
dc"ZMEt lit, E
.........
ram
Q,VRX S a wmm VW�I�w WMM��""'W
MM Imi"Not IT1010"N", lam W, R 1n"�-"-�A-ov`-",'r' '�dl Virmi`� !qT FAIR rPa w�Pliorldl
ZM Y:'.�
A P liddri:CdiM�' Y: W rM��
l:,:i4 rd: lk!Y� N it r. 18�1 �1111.1-�5 V0 lid,
N!t�mg MIUM�!!tplu iog:
81 c)AED excursion 0 0
Envelope losalgain 8148 4241 3940 3568
12 a) Infiltration 1361 398 1011 295
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants a 230 2 460 2 460
Appliances C 1200 0 0 1 1200
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 9509 5099 4950 5513
15 Duct loads 24% 41% 2280 2106 24% 41% 1187 2278
Total row load 11789 7205 6137 7791
321
Air required(cf1m) T 4311 2971 2241 id
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
%01 464 2005-Oct-06 19:10:28
Right-SuiteReSidential6.0.02RSR2 2
A&kC:\MyDocumertts\WrightsoftHVAC\BP167605.rrp Calciddi Orientation-N Page 2
Right-J Worksheet Job:
Entire House Date: Oct 05,2005
MONICA BACCA By:
4891 TIMUQUANA ROAD,JACKSONVILLE,FL 32210 Phone:904-737-5499 Fax:904-779-7D98 Email:mbjagsaaarthlink.net
1 Room name BR31BTH
2 Exposed wall 42.0 ft
3 Ceiling height 9.0 ft heattcooll
4 Room dimensions 22.0 x 20.0 ft
5 Room area 440.0 ft'
Ty Construction U-value Or HTM Area (" Load Area Load
number (Btuh/ft2--F) t or perimeter ( h) or perimeter
Heat Cool Gross N/P/S H,,t CW Gros, N/P/S Heat Cool
6 8 -.Y
--V
SUN
c 16C-30al 0.032 1.15 1.44 440 440 507 BU
-4*w'*W10www:, 0,
WN
1�N N� 16 AW"', 2 4 ffth$M��V two o! �y
F 22A:!ph 1.358 48.89 0.00 0 0 0 0
--g :� ::,���! -
N MINA oN q; "'MCF,10,e_,4:M 0::::�1$
01'0 u vy
I..........
.............
4-1 , ,-,,, - �
i �,,, M--,-3,, !W-, S=
A], M M
9:X�
% w1wag"W0101, IRH,`�T Noma U04"ftftw
�12-10011+- sn"NI'm no MY, WARM A01 2
4,1214 RANU AN "'Ai: n VOY ARM
M-v
U
60Y
-NOM
, I 1� W'"R 'wo Q! Jffi�;K;N%4R� �Am S,
WA611,hg-I
X
NP: ;5 o 4 qoo::!M
q
wwwamtMo ME=M"a"Dma%Wvw��mum MN"own amm RINW�::z`
"N No$�ftnxgt�, "s �,VAO U, 1U 01""v7
ME"R',";N,MOM MR1319: V, R15P
4�50=11 OR 90 9� �l: OW"!! �Aw,`�, 'A"'iR1660' WUNWi 1
�R '60
AM 4
NNW=,' 01 h"1111�
,w� �Wqw vo .W-'
ME
E PPAW W7,01 MW 0 W 0- Mamt q
MW ZANNUMI loomwo `11a ARM A�00ffl F;%wWP11 ME, V on,
3 �4
ao� .....................
N
N
�I W's, N WOO RIPwar,"P, Ili A S Et
o0i R U N, A
ft 014
01 2w 113 w MR, RE 0 V
P
MAIR �1� 191,0-1`1`001i 1-l"', ��� 41��i
0
M 4— 1N
MUMW V r-.. N�',T
pou MW,', Rolm, 5
80
0 :41--, A-
Y V,
P la
6 c)AED excursion 01
Envelope loss/gain 3029 2554
12 a) Infiltration 866 263
b) Room ventilation 0 0
13 Internal gains: Occupants Q 230 2 460
Appliances(a 1200 1 1200
Lose external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 3896 4467
15 Duct loads 24% 41% 934 1846
Total room load 4829 6312
Air reqWred(cfm) 177 260
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
Right-Suite Residential 6.0.02 RSR24642 2005-Oct-06 19:10:28
A&-k C:\My Documents\Wrightsoft HVAC\BP167605.rrp Calc-MJ8 Orientation=N Page 3
Lb
IL
IL
Lil
(A A>
79
r
ro
130OL— EVARo
(0c) R/W
DOC # 2005303260, OR BK 12690 Page 1557, Number Pages: 1, Filed & Recorded
09/27/2005 at 10:28 AM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTy RECORDINC;
$10.00
Permit Number:
Tax Folio Number: 170173-0000
State of Florida
County of Duval
File Number: OST0726
NOTICE OF COMMENCEMENT
The undersigned hereby gives notice that improvement will be made to certain real property,and,in accordance with
Chapter 713,Florida Statutes,the following information is provided in this Notice ofCommencement.
I Description of Property:
Lot 5,Block 23,ATLANTIC BEACH.according to plot thereofas recorded in Plat Book 5,Me 69 of the
current public records of Duval County,Florida.
2. General Description of Improvements: Constuction Rehab on single family residential dwelling
3. Owner Information:
a. Name and Address: Lynn L.Hileman and Arthur R.Porcelli.,III
322 4th Street,Atlantic Beach,M 32233
b. Interest in property; Fee Simple
C. Names and address of fee simple title holder(ifother than owner):
4. Contractor. R.S.Pennington,General Contractor
1084 12th Street North,Jacksonville,FL 32250
5. Surety: N/A
6. Leader. Oceanside Bank,1315 S.Third Street,Jacksonville Beach,Florida 32250
7. Persons within the State of Florida designated by Owner upon whom notices or other docunwnts may be served
as provided by Section 7 1 3.13(l)(a)7.,Florida Statutes.
S. In addition to himself,Owner designates the following persons to receive a copy of the Lienor's Notice as
provided in Section 713.13(f Xb),Florida Statutes,
9. Expiration date of.Notice of Commencement(the e a is I year from 6 of cording unless a
d!0rent date cified):
Lynn I�Hileman AAhur R.Porciffif
Sworn to and subscribed before me August 12,2005 by Lynn L.Hileman and Arthur R.Porceiii,III who is personally
known to me or who did proyjdc DMERLs tiftw3e as identification.
-W-1Z A
NoF*6 Aiblic
My Commission Expires: G1 ENDA M- STATE OF FLORIDA
.""�IIUNTY
I&IOGNED Clark Of the Circuit COult.Nvrf County,
06-7- '—Y6ftA2l5-HERE6Y CERTIFY the within and 1`010 DRIA it$tfut
Prepared by and Record and Return to: and cwrgct copy ot the orivinal a it ap�elhv 1-11 WOW In -i 0
Watson and Osborne Title Scrvices�Inc. in tho offia 7f th* Clark Of Cirguit 'Ctirt Of Duval Wure-Y,
208 Ponte Vedra Park Drive,Suite 10 1 FGAU, and its wat is.ifLW IW20. nd eflect
Ponte Vedra Beach,Florida 32082 WITNEU my hand andl#,,a.P 18 C.;"'. I fl#�\
jockstin'i.;*' -/.;. — 0-i
4,
JIM WLDER
qw, circu4ie*nid'�County C",
011 Val coo M1 rl\�'
F 7
WA
T:390d 01 WH02:60 03M S002-2T-iX
NOTE "
c
to opprov (5 ony lood
bc, forc
0'4-0"
GANT 20-2-0
F06(10 24"OC
F04
F03 5
PEAM DYIOTEE6
F05 5
DEAM DY OTHE 5
F02 13 DEAM DY OTHM
F05 6
0'4-b"CANT
IL
FQIA
4 �EAM DY OTHER5
FOIA 3
DEAM DY OTHER5
7UTTT--
XIIL
�:Q
10-2-0 0'5,0"
CANT
NOTE � Truc�c�o(� (
Jcc� leric� tc
Ony � Oojc
to Opprovff,
bc� forff
0'4-8"
14-10-0 20-2-0 > CANT
24"06 F06(10
F04
C?
FO)15
DEAM DY OTHEK5
F05 5
DEAM 5Y OTHE6
F02(13
5EAM DY OTHER5
_FC5(6)
0'4-6"CANT
OEAM DY OTHR5 FOIA 5
�EAM DY OTHE95
FOI 5 -4 1
im
C�
lw�
CD
24-10-0
DEARING HEIGHT 56HEDULE
�ro not 10, 1-V811
) ':�Upport VARNING : 20' 7-0"
) f r o rn Extorior hieh hcol hovo boon
or dock , holJ �oo� 112'' for �,,xtcnor woll
U01
UO3
11L
NOTE5:
1.)REFER TO HID q1(RE60MMENDATION5 FOR
HANDLIN6 IN5TALLATION AND TEMPORARY DRACIN6)
REFER To EN61NEEPED OFAWIN65 FOR PERMANENT
DRACIN6 REQUIRED
T14 8 2)ALL TRU55E5(INCLUOIN6 TRU55E�UNDER
VALLEY FRAMIN6)MU5T DE COMPLETELY
DECKED OR REFER TO DETAIL Vn FOR
ALTERNATE DRACIN6 REQUIREMENT5.
3)ALL VALLEY5 ARE TO DE CONVENTIONALLY
Cp FRAMED DY DUILDER.
4.)ALL TRU55E5 APE DE516NED FOR 2'o G.
MAXIMUM 5FACIN6,UNLE55 OTHERW15E NOTED.
5.)ALL WALL5 5HOWN ON PLACEMENT
PLAN ARE GON51DERED TO DE LOAD
DEARIN6,UNLE55 OTHERW15E NOTED.
T11 6.)5Y42 TRU55E5 MU5T DE IWALLED
WITH THE TOP DEIN6 UP
7.)ALL ROOF TRU55 HAN6ER5 TO DE 5iMP50N
HU1,26 UNLE55 OTHERW[15E NOTED ALL
FLOOR TPU55 HAN6E?5 TO DE 5IMF5ON
THA422 UNLE55 OTHERWI�E NOTED�
Tob 6.)5EAMIHEADER/LINTEL(HDP)TO DE
FURN15HED DY DUILDER
Builders
�5
k.AFirstSource
Dunnall
AIN PHONE:366-437-334q FAX:366-457-3q,14
Jack,,onville
PHONE:PO4-772-6100 FAX:qO4-772-1c;73
Laka City
PHONE:306-755-66q4 FAX 366-755-7q73
Sanford
L02D PHONE:407-322-005P FAX:407-322-5553
LE&At APO?[55:
480 Ocean Dlvd.
NOVEL: RLY 15 1 ON
24-10-0 10-2-0 Forcalli Ratldanoa 77r——NT,�
OME: NAIN Dy JOD I
10/25/05 1 MCI J135450
HARM HE16HT 56HEPULE
Iro not 10, I-lib"
6�)Upport W /I\ RNING : 20, 7-01,
�rom Extonor Ngh hool hovo. boorT
hold �ock 112'' for oxterior woll
-17
GJ01
C>
T15
T15
f13
NOTE5:
t)REFER TO HID q1(�ECOMMENPAfION�FOR
HANDLING IN5TALLATION AND TEMPORARY DRACIN6.)
REFER TO EN61NEERED PRAWIN65 FOR PERMANENT
DRA61N6 REQUIRED.
T14(5) 2.)ALL TRU55E5(INCLUDING TRU55E5 UNDER
VALLEY FRAMING)MU5T DE COMPLETELY
DECKED OR REFER TO DETAIL V105 FOR
ALTERNATE DFA61N6 REQUIREMENT5
3)ALL VALLEY5 ARE TO DE CONVENTIONALLY
FRAMED DY DUILDER
4)ALL TRU55E5 ARE DE916NED FOR 2'o G.
MAXIMUM 5PACIN6,UNLE155 OTHERW15E NOTED
—m 5.)ALL WALL5 5HOWN ON PLACEMENT
PLAN ARE GON51PEREP TO DE LOAD
DEA?IN6,UNLE5�OTHERW15E NOTED
T111 6.)5Y42 TRU5�E5 MU5T DE IN5TALLEP
WITH THE TOP DENG UP.
T10 7)ALL ROOF TRU5�HANGER5 TO DE 5IMF5ON
HU526 UNLE55 OTHEFW15E NOTED ALL
T11 THA422 UNLE55 OTHERW15E NOTED.
FLOOR TRU�5 HAN6ER5 TO DE 5IMP50N
TO 8)DEAM/HEAPEFILINTEL(HOF)TO DE
T07 FURN15HED DY DUILDE?,
T06 Builders
T05 iioFirstSource
Dunnoll
T04
F-F- PHONE.366-437-334q FAX.366-437-3qq4
Oack-,onvilla
PHONE!q04-772-6100 FAk qO4-772-lq73
Lake Gity
PHONE:366-755-68q4 FAX:306-755-7q73
i2m� I —
Q) So&or4i
GdO2 PHONE:407-322-005P FAX,407-322-5553
DUILDER�
LE&AL 09IE55:
0'5-0" 480 Occom Dlvd.
GANT MOIL: REYIqON:
10-2-0 24-10-0 Forcalli Rce>ldewa la7 NTI�
AH 09&IN Dy' JOD#
10/25/05 MCI J135450
IBumilders
oFirstSource
Projqct Information for: J135450
Builder. Unknown
Address: 480 OCEAN BLVD.
ATLANTIC BEACH, FL q0bber 27,2005
�ounty: DUVAL
Truss Count: 41
Design Program: MiTek 20/20 6.2
Building Code: FBC2004/TP12002
Truss Design Load Information:
Gravity: Wind:
Roof(psf): 42.0 Wind Standard: ASCE 7-02 Wind Exposure: C
Floor(psf): 55.0 Wind Speed (mph): 120
Note: See the individual truss drawings for special loading conditions.
Engineer of Record:Frank J. Holas, PE Florida P.E. License No. 12564
Address: 12467 Toucan Drive Jacksonville, Florida 32223
Truss Design Engineer:Lawrence A. Paine, PE Florida P.E. License No. 21475
Company: Builders FirstSource-Florida, LLC Address: 6550 Roosevelt Blvd. Jacksonville, FL 32244
Notes:
1. Determination as to the suitability of these truss components for the structure is the responsibility of the building
designerlengineer of record,as defined in ANSI/TPl 1-2002 Section 2.2
2.The seal date shown on the individual truss component drawings must match the seal date an this index sheet.
3.The Truss Design Engineer's responsibility relative to this structure consists solely of the design of the individual
truss components and does not include the design of any additional structural elements including but not limited
to continuous lateral bracing elelments in the web and chord planes. See Florida Administrative Code
61 G1 5-31.003 sections 3 c)&5 and Chapter 2 of the National Design Standard for Metal Plate Connected
Wood Truss Construction ANSI/TPI 1-2002 for additional information on the responsibilities of the delegated
"Truss Design Engineer". Builders FirstSource and Lawerence A. Paine, PE do not accept any additional
delegations beyond the scope of work described in the referenced documents above.
No. lDrwg.# I Truss ID I Date I No. I Drwg.# Truss ID Date
1 1 J 153312 I-F01 1 10127/05 129 IJ1533150 T07 �7/�05
12 IJ1533123 I-F01A 1 10/27/05 130 1 J 1533151 _TO8 10/27/05
:02 1 10/27/05 131 IJ1533152 T09 10/27/05
14 IJ1533125 I-FO3 1 10/27/05 132 IJ1533153 IT10 10/27/05 1
5 IJ1533126 I-FO4 1 10/27105 133 IJ1533154 j T11 10/27/05
6 J 1533127 I-FO5 1 10/27/05 134 _IJ1533155 T12 1.0127/05
17 J1 533128 11706 1 10/27/05 135 IJ1533156 IT13 10/27/05
t7/05 136 1 J1 533157 IT14 10127/05
9 J 1533130 1 CJ01 1 10127/05 137 _.._I J 7/05
10 IJ1533131 ICJ01A 1 10/27/05 138 IJ1533159 T17 10/27/05
Ill J1533132 CJ01B 1 10/27/05 139 1 J 1533160 T18 10/27/05
12 J1533133 CJ02 1 10/27/05 140 IJ1533161 T19 1.0/27/05
13 1 J1 533134 jCJ02A 1 10/27105 141
14 IJ1533135 IC 02B 10/27105 1 .._IJ1533162 JT20 1 10/27/05
15 IJ1533136 CJ03 10/27/05 1
16 IJ1533137 i EJ01 10/27105
17 IJ1533138 IEJ02 10/27/05
18 IJ1533139 JEJ03 10/27/05
119 IJ1533140 11-1,101 10/27/05
20 IJ1533141 IHJ02 1 10/27/05 j
22 J1533143 HJ04 10/27/05
J23 J1533144 T01 10127/05
124 J1533145 I T02 10/27/05
25 J153314�::LT03 10127/05
26 J1533147 T04 10127/05
!27 J1533148 T05 1 10127/05
28
.............. CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 05-00031564 Date 11/21/05
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . ADD 2ND FLR OVER 1ST FLR
Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 190000
Owner Contractor
------------------------ ------------------------
PORCELLI R. S . PENNINGTON CONSTRUCTION
480 OCEAN BLVD. 380 13TH AVE N
JACKSONVILLE FL 32223 JAX BEACH FL 32250
(904) 993-2000
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 780 . 00 Plan Check Fee . 00
Issue Date . . . . valuation . . . . 190000
Expiration Date . . 5/21/06
----------------------------------------------------------------------------
Other Fees . . . . . . . . . WATER IMPACT FEE 380 . 00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 780 . 00 780 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 380 . 00 380 . 00 . 00 . 00
Grand Total 1160 . 00 1160 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUI�LD NG WTF-ICIAL
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 05-00031142 Date 9/06/05
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . DEMO
Application description . . . DEMOLITION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
JOINER, J.H. R. S r4�Ai I W
480 OCEAN BLVD. A ( " =5 T
JACKSONVILLE FL 32223 H Ff
----------------------------------------------- -----------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . .
Permit Fee . . . . 100 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- --------- - ----------
Permit Fee Total 100 . 00 100 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 100 . 00 100 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUILDING OFFICIAL
CITY OF ATLANTIC BEACH
DEMOLITION PERMIT APPLICATION
r J
49-
Date:
Job Address:
Owner of Property:
Address: Telephone:
Legal DescZrItio - B1 kNumber: Lot Number: Zoning District:
State License Number: 49
Contractor- &VV1AreVd ��u&,X�
Contractor's Address:
Telephone: Fax:
Describe proposed use and work to be done: o96PWO) A162
Present use of land or building(s):
Is approval of Homeowner's Association or other private entity required? Abf yes, please submit with this
application.
Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees?
NO. Applicant certifies that no change in site grade or rill material will be used on this project.
YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building
Permit.
NO. Applicant certifies that no trees will be removed for this project.
0 YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree
Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month.
Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate
Incomplete applications may result in delay in issuance of permit.
STEP 1. Attach Tree Removal Application if trees are to be removed or relocated
I hereby certify that all infbrmatiopJ�rovided w�'th this a li on is��O-i�ct.
pp �i(
Signature of Owner: Date:
I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and
ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to
give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the
governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the
above information being true and correct and that the plans and supporting data have been or shall be provided as required.
800 Seminole Road -Atlantic Beach,Florida 32233-5445
Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ei.atlantic-beach.fl.us
ATLANTIC BEACH BUILDING DEPT.
PROPERTY OWNER
DEMOLITION
RELEASE FORM
Date:
To Whom It May Concern:
I /We the current property owners of: Lot
Block
Legal Description of Property
AKA CtMd I!k bW have contracted with to have
(Address of Property)
Lf-t o r e m o v e t h e
(Company Name) (Single Family,Dupl&,Commercial,etc.)
A-10 &Z
_4'j�
Prior to the construction of 2
As a condition of issuing the permit we agree to the following:
I. All utilities are to be located and clearly marked.
2. Once house is removed, lot is to be graded and leveled.
3. All construction debris is to be removed from the property.
4. Affected area is to have grass or seed in place.
5. Erosion control deyjce� will be put in place and will remain in place until grass
ha overed affected 6rea or new structure is completed and landscaping is in
e.
Signature
Signature
THIS SPACE FOR RECORDER'S USE ONLY
OWNER
Signed: Date:
Before mn7ethi day of Y in the County of Duval,State
Opft A DVmn Of Florida,h erson p�
ally appeared 21z:
MYCOMWA"# DD759940 EMS
October 2Z 2007 Notary Public at Large,State of Florida,County of Duval.
IONWIMTROYFAMNSU24K4 W- My corrunission expires: 7-2-
Personally Known: or
Produced Identification:
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 05-00031684 Date 11/28/05
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . TEMP POLE
Application description . . . ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI BARKOSKIE ELECTRICAL SERVICE,
480 OCEAN BLVD. INC.
JACKSONVILLE FL 32223 48 S . PENMAN ROAD
JAX BEACH FL 32250
(904) 246-4731
-------------------------------------------------------------------------- --
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 140 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- -- --------
Permit Fee Total 140 . 00 140 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 140 . 00 140 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUILDING OFFICLkL
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 05-00031742 Date 12/05/05
Property Address . . . . . . 480 OCEAN BLVD
Tenant nbr, name . . . . . . INSTALL 15 FIXTURES
Application description . . . PLUMBING ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
PORCELLI JERRY' S PLUMBING
480 OCEAN BLVD. 4745 BELLADONNA
JACKSONVILLE FL 32223 PITTS, JERRY EDWIN
MIDDLEBURG FL 32068
(904) 307-7574
------------------------- ---------------------------------------------------
Permit PLUMBING PERMIT
Additional desc . .
Permit Fee . . . . 140 . 00 Plan Check Fee . 00
I-ssue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 140 . 00 140 .00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 140 . 00 140 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUIL
CITY OF ATLANTIC BEACH
PLUMBING PERMIT APPLICATION
Date:
Property Address: (3 q_x o
r
Owner: / I I Telephone
Contractor: 0_" 'PP. C(—L) A-� b'I ru Telephone#:
Contractor Address: Fax#:
Contractor Signature:
In consideration of permit given for&mg the work as described in the above statement we hereby agree to perform said work in
accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach
ordinance and standards of good practice listed therein.
Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing
Code.
Plumbing Type: If other construction is being done on this building or site,
�/New list the buildmi Sermit number:,
Q Re-Pipe
Number of Fixtures:
Bath Tubs 44 Showers
Closets Shower Pans
Dishwashers Sinks
Disposals Urinals
Floor Drains Washing Machine
Lavatory Water
Sewer Water Heaters
Sprinkler System Other
Fees
Permit Issuing Fee: $35.00
Total Fixtures: X$7.00 + $35.00
800 Seminole Road-Atlantic Beach, Florida 32233-6445
Phone: (904)247-5800- Fax., (904) 247-5846- hftp:itwww.ci.atiantic-boach.ft.us
Revised 1104
Job _russ Truss Type Qty ply I Job Reference(optional) J1
J135450 F01 FLOOR 8
Builders First Source,Jacksonville Florida 32244 6.200 e Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 11:49:23 2005 Page 1
0-1-8
H 1-9-8 Scale 1:43.3
4x10 3x4
WO 3x6 FP= 3x4 2x4 3x4 3x4 3x4 4x10
1 2 3 4 5 6 7 8 9 10 11 12
29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13
7x10 4x6 3x4 4x6 11 4x6 11 3x8 MT20H FP 4x6
3x4= 3x4
0-6-4 24-9-8
0- 2 24-5-0 24
0-4-12 23-10-12 0-1-�
0-1-8 0-3-0
Plate Offsets(X,Y): [1:0-2-8,Edgel,[6:0-1-8,Edgel,[7:0-1-8,0-0-01,[11:0-1-8,Edgel,[1 2:0-4-0,Edgel,[1 5:0-1-8,Edgel,[29:Edge,0-1-8],[30:0-1-8,0-2-P]
LOADING(psf) SPACING 1-4-0 csI DEFL in (ioc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.42 21 >688 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.69 Vert(TL) -0.66 21 >439 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(TL) 0.08 13 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:159 lb
LUMBER BRACING
TOPCHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 5-10-4 oc purlins, excpflt
BOTCHORD 4 X 2 SYP No.1 D*Except* end verticals.
17-27 4 X 2 SYP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 4 X 2 SYP No.3
REACTIONS (lb/size) 29=3130/0-3-8,13=896/0-3-8
Max UpIift29=-1 742(load case 4)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 29-30=-3112/1745,1-30=-3044/1708,12-13=-894/0,1-2=-1177/0,2-3=-2721/0,3-4=-2721/0,4-5=-3805/0,5-6=-4479/0,
6-7=-4743/0,7-8=-4743/0,8-9=-4462/0,9-1 0=-3697/0,10-11=-2511/0,11-12=-1 097/0
BOTCHORD 28-29=-90/161,27-28=0/2036,26-27=0/2036,25-26=0/3349,24-25=0/4258,23-24=0/4258,22-23=0/4743,
21-22=0/4743,20-21=0/4682,19-20=0/4226,18-19=0/4226,17-18=0/3170,16-17=0/3171,15-16=0/3171,
14-15=0/1911,13-14=0/0
WEBS 12-14=011367,1-28=0/1284,11-14=-1132/0,2-28=-1 195/0,11-15=0/834,2-26=0/929,10-15=-918/0,4-26=-852/0,
10-18=0615,4-25=0/618,9-18=-701/0,9-19=0/76,5-25=-602/0,9-20=0/314,5-23=0/379,8-20=-386/0,6-23=-602f76,
8-21=-221/424,7-21=-1 38/3,5-24=-1 0/53,6-22=-1 55/239
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 3x6 MT20 unless otherwise indicated.
4)The following joint(s)require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection:
16 and 3.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1742 lb uplift atjoint 29.
6)Required 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to
walls at their outer ends or restrained by other means.
7)CAUTION,Do not erect truss backwards.
8) In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). Truss Design Engineer:Lawrence A.Paine,PE
Loading has been calculated by the truss manufacturer. It is the responsibility Florida PE No.21475
of the Architect/Engineer of Record to verify and approve the loading. Builders FirstSource-Flori4 LLC
LOAD CASE(S) Stanclai�d Except:
Continued on page 2 6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
will& all a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown.and is for an individual building component to be IS
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FirstSource
Job Truss Type—:— Oty Ply
russ T J1 5331:
J 135450 _F01 EFLOOR 8 1 �j b Reference(optional)
0
Builders First Source,Jacksonville Florida 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 11:49:23 2005 Page 2
LOAD CASE(S) Standard Except:
1)Floor:Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(pl�
Vert:13-29=-7,1-12=-67
Concentrated Loads(lb)
Vert:1=-2249(F)
4)User defined:Lumber lncrease=1.00,Plate Increase=1.00
Uniform Loads(pl�
Vert:13-29=-4(F),1-12=-8(F)
Concentrated Loads(lb)
Vert:1=1892(F)
Tnus Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Build rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& warning verify design parameters and READ NOTES ON TNIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of indMdual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
garding fabrication,quality control,storage,deli�ery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 MFirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onotrio Drive,Madison,WI 53719
Job �_russ Truss Type Q A 533123
A 35450 F01A FLOOR 3 ty ply 1 �Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6,200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:08:46 2005 Page 1
0-1-8,
P134? 1-3-0 1-7-8 O-A-8
SEhle=1:43.0
4x6
5x6 11 4x6
2;- 3x6 FP= 3x4- 3x4 2x4 11 3x4 3x4 4x6
2 3 4 5 6 7 8 9 10 11 12 13
2 33 9
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
3x4= 4x6 3x4 5x6 I I 4x6 I I 3x6 FP= 4x6
5x6 11 3x4
0-6-4
014-1? 24-6-12
0-4-12 24-0-8
0-1-8
Plate Offsets(X,Y): fl:0-1-8,Edgel,[7:0-1-8,Edgel,[8:0-1-8,0-0-01,[30:0-1-8,Edgel,[32:0-1-8,0-2-91,[33:0-1-8,0-1-81
LOADING(psf) SPACING 1-4-0 CS11 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.45 Vert(LL) -0.36 21-22 >793 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.67 Vert(TL) -0.57 21-22 >506 240
BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(TL) 0.06 14 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:155 lb
LUMBER BRACING
TOPCHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, exceIR)
BOTCHORD 4 X 2 SYP No.1 D*Except* end verticals.
18-28 4 X 2 SYP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
WEBS 4 X 2 SYP No.3 6-0-0 oc bracing:29-30.
REACTIONS (lb/size) 14=833/0-3-8,30=2662/0-3-8
Max Uplifl:30=-1427(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 31-32=-54/19,1-32=-54/19,14-33=-836/0,13-33=-826/0,1-2=-547/599,2-3=-674/90,3-4=-1 920/0,4-5=-1 920/0,
5-6=-3066/0,6-7=-3819/0,7-8=-4150/0,8-9=-41 50/0,9-1 0=-4007/0,10-11=-3351/0,11-12=-2267/0,12-13=-952/0
BOTCHORD 30-31=-1/3,29-30=-573/553,28-29=0/1 206,27-28=0/1 206,26-27=0/2585,25-26=0/3559,24-25=0/3559,23-24=0/4150,
22-23=0/4150,21-22=0/4167,20-21=0/3810,19-20=0/3810,18-19=0/2880,17-18=0/2880,16-17=0/2880,
15-16=0/1 709,14-15=0/86
WEBS 2-30=-971/0,13-15=0/1 152,2-29=0/1 172,12-15=-1 054/0,3-29=-1 182/0,12-16=0/775,3-27=0/969,11-16=-852/0,
5-27=-903/0,11-19=0/640,5-26=0/652,10-19=-609/0,10-20=0/54,6-26=-654/0,6-25=0/58,10-21=01260,6-24=0/428,
9-21=-299/11,7-24=-672/17,9-22=-311/308,7-23=-101/276,8-22=-102/30,1-30=-1770/1614
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 3x6 MT20 unless otherwise indicated.
3)The following joint(s)require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection:
17 and 4.
4)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1427 lb uplift at joint 30.
5)Load case(s)6 has/have been modified.Building designer must review loads to verify that they are correct for the intended use of this
truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
7)CAUTION,Do not erect truss backwards. Trws Design Engineer:Lawrence A.Paine,PE
8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). Florida PE No.2147.5
LOAD CASE(S) Standard Except: Bailders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
Warning-Verify design parametom and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111-7473 BEFORE USE
dowk IRS 2
Design valid for use only with MiTek connectors.This design is based only upon parameters shown and is for an individual building component to be
Inst lied and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
desegner.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
r,
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Fir-l-l"nurc
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719
Job Truss Truss Ty�pe �� Oty Ply
J135450 �FO I�A �� J153312
FLOOR 3 1 �Job Reference(optional)
Builders First Sourm,Jacksonville-,Flonda 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:08:46 2005 Page 2
LOAD CASE(S)Standard Except:
1)Floor:Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf)
Vert:14-31=-7,1-13=-67
Concentrated Loads(lb)
Vert:1=-1725(F)
6)User defined:Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf)
Vert:14-311=4fl,1-13=-8(F)
Concentrated Loads(lb)
Vert:1=1547(F)
Truss Desio Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Build rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& warning-verlift design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE NIII-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shom,and is for an individual building component to be
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the UUMM
I responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
I regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
MFirstSwrc
1 Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply 00 J1534067
J135450 -F02 FLOOR 13 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Thu Oct 27 09:54:11 2005 Page 1
0-1-8
1-3-0 1-11-12 0�8
H�-q i Scal 1:30.1
5x6=
2;= 4x6— 3x6 410 4x6
2 3 4 5 6 7 8 9
9
-:E
19 ��8 17 16 15 14 13 12 11 10
5X6 4x6 3x6 3x6-- 3x6 4x6
Simpson THA422 into
Beam by others.
0-6-4 2-2-0 4-8-0 7-2-0 11-0-4 13-6-4 16-0-4 17-6-4
0-6-4 1-7-12 2-6-0 2-6-0 3-10-4 2-6-0 2-15�0 "_0
Plate Offsets(X,Y): [1:Edge,0-1-8], [5:0-4-8,Edge], [20:0-1-8,0-1-0
LOADING (psf) SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TIC 0.59 Vert(LL) -0.17 14-15 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.25 14-15 >794 240
BCLL 0.0 Rep Stress Incr NO WB 0.61 Horz(TL) 0.04 10 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:98 lb
LUMBER BRACING
TOP CHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 4X2SYPNo.1D 6-0-0 oc purlins, except end verticals.
WEBS 4 X 2 SYP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
6-0-0 oc bracing: 17-18.
Recommended hanger connection based on manufacturer tested capacities
and nail calculations. Conditions may exist that require different connections
REACTIONS (lb/size) 10=857/Mechanical, 18=2841/0-3-8 than indicated. Refer to manufacturer publication for additional information.
Max Uplift 18=-1293(load case 4) Hanger connection to be reviewed and approved by the Arch itect/Engineer
of Record.
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 19-20=-35/17, 1-20=-35/17,9-10=-852/0, 1-2=-617/791,2-3=-730/255,3-4=-1636/0,
4-5=-2462/0, 5-6=-2730/0, 6-7=-2730/0,7-8=-2037/0,8-9=-851/0
BOTCHORD 18-19=-1/2, 17-18=-762/623, 16-17=0/1059, 15-16=0/2186, 14-15=0/2730,
13-14=0/2730, 12-13=0/2456, 11-12=0/1601, 10-11=0/0
WEBS 2-18=-1 076/0, 9-11=0/1 133,2-17=0/1 229, 8-11=-1 043/0, 3-17=-1 164/0, 8-12=0/607
3-16=0/803,7-12=-582/0,4-16=-764/0, 7-13=-36/586,4-15=-21/495, 5-15=-6267/9&Design Engineer:Lawrence A.Paine,PE
5-14=-125/166, 6-13=-258/0, 1-18=-1944/1515 Florida PE No.21475
Builders FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
1 =0.90, 2=0.77,3=0.83,4=0.58,5=0.38,6=0.38,7=0.68,8=0.71,9=0.71, 10 0.65, 11 0.71, 12=0.71, 13
0.64, 14=0.64, 15=0.58, 16=0.83, 17=0.77, 18=0.91, 19=0.63, 20=0.00 and 20 0.47
NOTES
1) Unbalanced floor live loads have been considered for this design.
2)All plates are 3x4 MT20 unless otherwise indicated. October 27,2005
§b&W4W0firp@6%assumed to be SYP No.2 crushing capacity of 565.00 psi
Warning-Vanity dosign param*ltors and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11101111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design parementers and proper incorporation of component is responsibility of building designer-not truss
designer.B Ing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the WHICIL"
mc
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
garding f brication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
a mFirstSourc
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,W 153719
Job russ Tru s Type Qty Ply 0
J1534067
J135450 -F02 FLOOR 13 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MlTek Industries,Inc. Thu Oct 27 09:54:112005 Page 2
NOTES
4) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1293 lb uplift at joint 18.
5) Load case(s)4 has/have been modified.Building designer must review loads to verify that they are correct for the intended use
of this truss.
6) Recommend 2x6 strongbacks,on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
7) CAUTION, Do not erect truss backwards.
8) Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s) 1805 lb down and 1404 lb
up at 0-2-4 on top chord. The design/selection of such connection device(s)is the responsibility of others.
9) In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
LOAD CASE(S) Standard Except:
1) Floor:Lumber Increase=1.00, Plate lncrease=1.00
Uniform Loads(plf)
Vert: 10-19=-10, 1-9=-100
Concentrated Loads(lb)
Vert: 1=-1805(F)
4) User defined: Lumber lncrease=1.00, Plate lncrease=1.00
Uniform Loads(plf]l
Vert: 10-18=6fl, 1-9=-12(F)
Concentrated Loads(lb)
Vert: 1=1404(F)
Truss Design Engineer:Lawrenre A.Paine,PE
Florida PE No.21475
Build rs FirstSource-Florida,LLC
6550 Roose,.relt Blvd.Jacksowille,FL 32244
October 27,2005
�, �����MITEK�REFER�ENCEPAGE M111.7473 B�EFORE.USA
ng-Ve ly d Ign and R E HIS A LUDED E
acing to insure stability during construction is the
f the building designer.For general guidance -91
andard,DSB-89 Bracing Specification,and HIB kzFirstSource
W "1 6 Para-o**- g-NOT S ON T ND'NC K'I M C M
t
.m'.n.t.be
d d is for an individual W.Wing component to be
is be upon ho_n, .d or . 'ng n_no,truss
ant is responsibility of building designer-not truss
r
h h d. g d W, is is r-n of d g
d d an na,'fly b ldn iss,
an..
g a p-r-m-he
.1 n Is
as, �-h is 'ca", _ n proper,. of .m_.. d
rid of d "m t .corpora m ... ..c to
bi� g a " d 'n is'.'.a n is i ciris
ty iss, nisr'.
d, general
riw,Madison,Wl 53719
d a pp".. 'it' b th
"'.1all
""__n is'. is for'at.-' - of in on
."f.. .'. dclib. .nf r is rl strui.ture is l-rs`sp.�.'"it, if
g b n.'r-a is,.-V, . rec, a.. 'ST.. St.nd.r racm, cation,
d d
is nc.".�''u.l� ntr',at.age --h- .0 gS
.,a d in and r Tr a institute no ad,...
Job Truss Truss Type Qty Ply J1534068
J1 35450 _F03 FLOOR 5 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 09:54:12 2005 Page 1
0-1-8
1-3-0 1-11-0 018
-Kle=1:35.3
6.8 11 46
4X6 4x6 4x10 3x6 3x6 2x4
2 3 4 5 28 6 7 8 9 10
-- 27 9
25 23 22 21 20 19 18 17 16 15 14 13 12
6x8 46 56 11 36 11 5x6 11 6x8 36 11 36 11 3x8MT20HFP= 46
36
4-8-0 7-2-0 13-7-0 16-1-0 18-7-0 2G-1-0
P-6.1 2-2-0 i i i 1
0-&4 1-7-12 2-6-0 2-6-0 6-5-0 2-6-0 2-6-0 1-&0
Plate Offsets(X,Y): [1:0-1-8,Edge], [5:0-4-8,Edge], [10:0-1-8,Edge], [118:0-3-0,Edge], [19:0-3-0,Edge], [26:0-1-8,0-1-13], [27:0-1-8
10-1-0]
LOADING (ps� SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.25 18 >920 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.93 Vert(TL) -0.39 18 >588 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr NO W13 0.71 Horz(TL) 0.05 11 n/a n/a
BCDL 5.0 1 Code FBC2004/TP12002 (Matrix) Weight: 127 lb
LUMBER BRACING
TOP CHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 4 X 2 SYP No.1 D*Except* 6-0-0 oc purlins, except end verticals.
11-14 4 X 2 SYP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
WEBS 4 X 2 SYP No.3 bracing, Except:
6-0-0 oc bracing:23-24.
REACTIONS (lb/size) 11=1005/0-3-0,24=2791/0-3-8
Max Uplift 24=-1498(load case 4)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 25-26=-46/14, 1-26=-46/14, 11-27=-1 005/0, 10-27=-1 003/0, 1-2=-719/712,
2-3=-851/109, 3-4=-2230/0,4-5=-3389/0, 5-28=-3954/0,6-28=-3954/0, 6-7=-3954/0,
7-8=-3578/0,8-9=-2522/0,9-10=-1029/0
BOTCHORD 24-25=-1/2,23-24=-680/726,22-23=0/1524, 21-22=0/1525,20-21=0/2941,
19-20=0/3946, 18-19=0/3954, 17-18=0/4006, 16-17=0/4006, 15-16=0/3167, Truss Design Engineer:Lawrence A.Paine,PE
14-15=0/3167, 13-14=0/3167, 12-13=0/1922, 11-12=0/52 Florida PE No.21475
WEBS 2-24=-1186/0, 10-12=0/1328,2-23=0/1401,9-12=-1243/0,3-23=-1403/0, Builders FirstSource-Florida,LLC
9-13=0/833, 3-21=0/1061,8-13=-898/0,4-21=-963/0,8-16=0/557,4-20=0/608, 6550 Fo.sevelt Blva.Jacksonville,FL 32244
7-16=-568/0, 7-17=-37/300, 5-20=-895/39,7-18=-572/544,6-18=-181/0,
1-24=-1751/1765,5-19=-132/391
JOINT STRESS INDEX
1 =0.71,2=0.88, 3=0.65,4=0.69, 5=0.38,6=0.38, 7=0.63, 8=0.63, 9=0.87, 10=0.76, 11 =0.76, 12=0.83, 13
0.87, 14=0.78, 15=0.00, 15=0.71, 16=0.77, 17=0.32, 18=0.32, 19=0.32,20=0.84,21 0.79, 22 0.00,22=8*ber 27,2005
ContA&P&Ppi�e=20.82,25=0.63, 26=0.00, 26=0.47,27=0.00 and 27=0.47
Warning-Verity design pararnaters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 BEFORE USE Owl as 0
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
desig WHOM
ner.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
rag ndling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 --'Source
arding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
He MFirst
Job russ Truss Type Qty Ply 0
J1534068
J 135450 —F03 FLOOR 5 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Thu Oct 27 09:54:12 2005 Page 2
NOTES
1) Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 3x4 MT20 unless otherwise indicated.
4)The following joint(s)require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance
inspection: 14.
5)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate at joint(s) 11.
7) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1498 lb uplift at joint 24.
8) Load case(s)4 has/have been modified.Building designer must review loads to verify that they are correct for the intended use
of this truss.
9) Recommend 2x6 strongbacks,on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
10) CAUTION, Do not erect truss backwards.
11) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back(B).
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/Engineer of Record to verify and approve the loading.
LOAD CASE(S) Standard Except:
1) Floor: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads(plD
Vert: 11-24=-10, 1-10=-100
Concentrated Loads(lb)
Vert: 1=-1633(F)
4) User defined: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads(pl�
Vert: 11-24=-6(F), 1-10=-12(F)
Concentrated Loads (lb)
Vert: 1=1632(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A^& Warning Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE fill BEFORE USE
BLAFE iff
truss
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of compon 00"huMers
Design valid for use only with 107ek connectors.This design is based only upon parameters shown,and is for an individual building component to be
ant is responsibility of building designer-not
designer.Bracing shown is for steral support of individual weld members only.Additional temporary bracing to insure stability during Construction is the
responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
-89 Bracing S c ication,and HIB-91
garding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB pe If
FirstSource
Handling Installing and Bracing Re ommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719
Job russ- Truss Type Qty Ply 00 J1534069
J135450 F04 FLOOR 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Thu Oct 27 09:54:13 2005 Page 1
0-1-8
1-3-0 1-11-0 118
H '.Ie=1:35.3
6x8 11 4x6=
2;�4x6 4x6 WO 3x6 3x6 2x4
2 3 4 5 6 7 8 9 10
�15 F, 27
19
25 [14 23 22 21 20 19 18 17 16 15 14 13 12
6X8 4x6 5x6 11 4x6 11 5x6 11 6x8 3x6 I I 3x6 11 3x8 MT20H FP= 4x6
3x6
R&I 2-2-0 44�0 7-2-0 13-7-0 16-1-0 18-7-0 20-1-0
0-64 1-7-12 2-6-0 2-6-0 6-5-0 2-6-0 2-r�O 1-6-0
Plate Offsets(X,Y): [1:0-1-8,Edge), [5:0-4-8,Edge], [10:0-1-8,Edge], [118:0-3-0,Edge), [119:0-3-0,Edge], [26:0-1-8,0-1-11], [27:0-1-8
10-1-0]
LOADING (ps� SPACING 2-0-0 CSI DEFL in (loc) I/clefl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.65 Vert(LL) -0.26 18 >885 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.95 Vi -0.41 17-18 >566 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr NO WB 0.71 Horz(TL) 0.05 11 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 127 lb
LUMBER BRACING
TOP CHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 4 X 2 SYP No.2*Except* 6-0-0 oc purlins, except end verticals.
14-25 4 X 2 SYP No.1 D BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
WEBS 4 X 2 SYP No.3 bracing, Except:
6-0-0 oc bracing:23-24.
REACTIONS (lb/size) 11=1027/0-3-0,24=2821/0-3-8
Max Uplift 24=-1498(load case 4)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 25-26=-44/13, 1-26=-44/13, 11-27=-1026/0, 10-27=-1025/0, 1-2=-719/712,
2-3=-851/32, 3-4=-2288/0,4-5=-3470/0, 5-6=-4044/0,6-7=-4044/0, 7-8=-3659/0,
8-9=-2576/0, 9-10=-1051/0
BOTCHORD 24-25=-1/2,23-24=-677/726,22-23=0/1567,21-22=0/1567,20-21=0/3013,
19-20=0/4037, 18-19=0/4044, 17-18=0/4095, 16-17=0/4095, 15-16=0/3237, Truss Design Engineer:Lawrence A.Paine,PE
14-15=0/3238, 13-14=0/3238, 12-13=0/1964, 11-12=0/53 Florida PE No.21475
WEBS 2-24=-1210/0, 10-12=0/1357,2-23=0/1429, 9-12=-1270/0,3-23=-1432/0, Builders FirstSource-Florida,LLC
9-13=0/851, 3-21=0/1082,8-13=-920/0,4-21=-983/0, 8-16=0/572,4-20=0/670, 65.50 Roosevelt Blvd.Jacksonville,FL 32244
7-16=-578/0, 7-17=-35/287, 5-20=-965/39,7-18=-475/547,6-18=-186/0,
1-24=-1750/1765,5-19=-129/362
JOINT STRESS INDEX
I =0.71,2=0.90, 3=0.67,4=0.76, 5=0.38,6=0.38, 7=0.63, 8=0.65,9=0.88, 10=0.78, 11 =0.78, 12=0.85, 13
0.88, 14=0.80, 15=0.00, 15=0.68, 16=0.79, 17=0.32, 18=0.32, 19=0.32,20=0.64,21 0.80, 22 0.00,22=&cA;ber 27,2005
ContAE-cPXPi?dd=2P.82,25=0.63, 26=0.00,26=0.47,27=0.00 and 27=0.47
Warning-Wrify dosign pmram*t*m and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ill BEFORE USE
Design valid for use only with MiTek connectom.This design is based only upon parameters shown and is for an individual building component to be
Instal ed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
kjFirstSource
i: Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss ype y 0 0 J1534069
J135450 _F04 FLOOR
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industdes,Inc. Thu Oct 27 09:54:13 2005 Page 2
NOTES
1) Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3) All plates are 3x4 MT20 unless otherwise indicated.
4)The following joint(s)require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance
inspection: 14.
5)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate at joint(s) 11.
7) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1498 lb uplift at joint 24.
8) Load case(s)4 has/have been modified.Building designer must review loads to verify that they are correct for the intended use
of this truss.
9) Girder carries tie-in span(s):2-1-0 from 0-0-0 to 20-1-0
10) Recommend 2x6 strongbacks, on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
11) CAUTION, Do not erect truss backwards.
12) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front (F)or back(B).
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/Engineer of Record to verify and approve the loading.
LOAD CASE(S) Standard Except:
1) Floor: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads(pl�
Vert: `11-25=-10, 1-10=-102(F=-2)
Concentrated Loads(lb)
Vert: 1=-1633(F)
4) User defined:Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads(plD
Vert: 11-24=-6(F), 1-10=-12(F)
Concentrated Loads (lb)
Vert: 1=1632(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Flori*LLC
6550 Roosevelt Blvd.JacksonviRe,FL 32244
October 27,2005
7473 EF
ly d*slgn dR IN N ANDINCLUDE EK REFERENCE PAGE 1111111-7473 BEFORE USE
RE US'
d is for an individual building component to be
ant is responsibility of building designer-not truss Bu
R GE"i B 0
d d u d nt to be
g b b d d. n of truss
W*-,ng V86 Para"' OT 0 TH's 0 7' P
v d on ._M.,r.s s'.r.n b
L � on base nl,up '.-n,an l f
nd d d "a b-aclora T mpo nt�.ra.'ns,�",. .0 ng ,g
a g rb lt n s the
cing to insure stability during construction is the
d
f the buildir g designer.For general guidance
.11 or-a. 'l'.. sgn are L. d proper f bn andard,DSB-89 Bracing Specification,and HIB-91 F i 5—J1,fE">ou rce
d '..rn tom .. l"d.ng
s b �d du structure's t po' fit,of, build-Ig d ,g..r or .n.,.l g. an..
on m
of d.
for, '.'au of� 'v,
rector '7 t f 'v
r. .nm d lion.pe an n re m. d r..'n l'..an
regarding I'll .1 the c. l' d rv.,-action and br.�'..consult .T__ l.n r �� g 'ca
ntr d l
.an"n' ,a.m. c.mm a. 'at, vf. is from Truss at.institute rive,Madison,Wl 53719
nv 's
d an rid on b no no
Job Truss Truss Type Qty Ply 00
J1534070
50 _F05 FLOOR 11 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 09:54:13 2005 Page 1
0-1-8
H�-4 1 1-3-0 1-9-12 Scale 1:29.3
5x6=
2� 4X6 3X6 4x6
2 3 4 5 6 7 8 9
T_ I
0
11978 17 16 15 14 13 12 11 10
5x6 4x6 3x6 W I I 4x6
Simpson THA422 into
Beam by others.
0-6-4 2-2-0 4-8-0 10-7-4 13-1-4 15-7-4 17-1-4
0-&4 1-7-12 2-6-0 5-11-4 2-6-0 2-6-0 1-&0
Plate Offsets(X,Y): [1:Edge,0-1-81, [6:0-1-8,Edge],(14:0-1-8,0-0-01,[20:0-1-8,0-1-0]
LOADING (psf)I SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TIC 0.80 Vert(LL) -0.17 13-14 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.92 Vert(TL) -0.27 13-14 >724 240
BCLL 0.0 Rep Stress Incr NO WB 0.61 Horz(TL) 0.04 10 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:94 lb
LUMBER BRACING
TOP CHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 4X2SYPNo.1D 6-0-0 oc purlins, except end verticals.
WEBS 4 X 2 SYP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
6-0-0 oc bracing: 17-18,16-17.
Recommended hanger connection based on manufacturer tested capacities
and nail calculations. Conditions may exist that require different connections
than indicated. Refer to manufacturer publication for additional information.
Hanger connection to be reviewed and approved by the Arch itect/Engineer
REACTIONS (lb/size) 10=833/Mechanical, 18=2820/0-3-8 of Record.
Max Uplift 18=-1294(load case 6)
Max Grav 1 0=834(load case 3), 18=2820(load case 1)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 19-20=-33/17, 1-20=-33/17,9-10=-828/0, 1-2=-616/794,2-3=-722/479,
3-4=-1550/29,4-5=-2532/0,5-6=-2532/0, 6-7=-2511/0,7-8=-1973/0,8-9=-820/0
BOTCHORD 18-19=-1/2, 17-18=-775/622, 16-17=-227/1023, 15-16=0/2089, 14-15=0/2532, Truss Design Engineer:Lawrence A.Paine,PE
13-14=0/2532, 12-13=0/2387, 11-12=0/1 542, 10-11=0/0 Florida PE No.21475
WEBS 2-18=-1 053/0, 9-11=0/1 092,2-17=0/1 212, 8-11=-1 004/0, 3-17=1 128/0,8-12=0TARQers FirstSour,,-Florida,LLC
, 3-16=0/734,7-12=-576/0,4-16=-751/0, 7-13=-14/279,4-15=-42/810, 6550 Foosevelt Blvd.Jacksonvffie,FL 32244
6-13=-278/245, 5-15=-326/16,6-14=-246/45, 1-18=-1951/1513
JOINT STRESS INDEX
1 =0.90,2=0.76, 3=0.86,4=0.84,5=0.38,6=0.63, 7=0.56, 8=0.70, 9=0.68, 10 0.38, 11 0.68, 12=0.70, 13
0.56, 14=0.47, 15=0.84, 16=0.86, 17=0.76, 18=0.91, 19 0.63,20=0.00 and 20 0.47
NOTES October 27,2005
'nbalanced fleeF live loads have been considered for this
If d d THIS Ar Pj ———il'R'ENCE PAGE 1111111-7473 BEFORE USE
Ir6 r�DED M'TEK RE
M.ReP, "'M!
IJEAD
I bhown,and is for an individual building component to be
ILJFE s
Ii bility of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabn tion,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installi ko
ng and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
FirstSource
Job Truss Truss Type Qty Ply 00
J1534070
J135450 —F05 FLOOR 11 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Thu Oct 27 09:54:13 2005 Page 2
NOTES
3)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
4) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1294 lb uplift at joint 18.
5) Load case(s)6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use
of this truss.
6) Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
7) CAUTION, Do not erect truss backwards.
8) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back(B).
LOAD CASE(S) Standard Except:
1) Floor: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads(plf)
Vert: 10-19=-10, 1-9=-100
Concentrated Loads(lb)
Vert: 1=-1805(F)
6) User defined: Lumber Increase=1.00, Plate lncrease=1.00
Uniform Loads (plf)
Vert: 10-19=-6(F), 1-9=-12(F)
Concentrated Loads(lb)
Vert: 1=1404(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Bluild rs FirstSouxce-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& Warning-Verffy design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIS-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be w
11116-
Installed and loaded vertically. Applicability of design paramenters,and proper incorporation of component is responsibility of building designer-not truss
d as OTS
igner.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
'ponsibillirty of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 &NirstSource
Job Truss Truss Type city Ply J 1533128
J 135450 _F06 FLOOR 10 1 J�O:Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:12:14 2005 Page I
1 3x4— 2 3x4 11 3
0-3-8 0-11-8 .P-1-E Scale 1:7.6
7
1x3
9
Simpson THA422
3x4
6 5 4
-7-12
0-4-8 - 2-0-0
0-4-8 0-1-12 x6 1-4-4 3x4
0-1-8
LOADING(psfi SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.05 Vert(TL) 0.00 5 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.18 Horz(TL) 0.00 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:19 Ib
LUMBER BRACING
TOPCHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, exceIR]
BOTCHORD 4 X 2 SYP No.2 end verticals.
WEBS 4 X 2 SYP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 4=-192/Mechanical,5=1050/0-3-8
Max Uplift4=-192(load case 1),5=-592(load case 2)
Max Grav4=1 76(load case 2),5=1 050(load case 1)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 6-7=-14/9,1-7�14/9,3-4=-169/191,1-2=-161/241,2-3=-161/238
BOT CHORD 5-6=-0/1,4-5=0/0
WEBS 2-5=-146/0,3-5=-334/226,1-5=-682/457
NOTES
1)Provide mechanical connection(by others)of truss to bearing plate capable ofwithstanding 192 lb uplift at joint 4 and 592 lb uplift at
joint 5.
2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
3)CAUTION,Do not erect truss backwards.
4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/Engineer of Record to verify and approve the loading.
LOAD CASE(S) Standard Except:
1)Floor:Lumber Increase=1.00,Plate lncrease=1.00
Uniform Loads(plf)
Vert:4-6=-1 0,1-3=-1 00
Concentrated Loads(lb)
Vert:1=-672(F) Truss Design Engineer:Lawrence A.Paine,PE
2)User defined:Lumber Increase=1.00,Plate Increase=1.00 Florida PE No.21475
Uniform Loads(plf) Builders FirstSource-Florida,LLC
Vert:4-6=-6(F),1-3=-12(F) 6550 Roosevelt Blvd.Jacksonville,FT.32244
Continued on page 2 October 27,2005
Warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Ins
tailed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
de I
signer.Bracing shown is for ateral support of individual web members only.Additional temporary bracing to insure stability during construction is the 110M
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabdcation,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Remmmendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 Firstsource
Job Truss russ Type oty
J153312
J135450 _F06 FLOOR 10 1
77Jb Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 e Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:12:14 2005 Page 2
LOAD CASE(S)
Concentrated Loads(115)
Vert:1=447(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
warning-verity design paramot*m and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with MiTelk connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded verfically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
DUBOW.",
designer Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsilbillity of ft erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 urce
garding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 k0Fr5l 0
Job Truss Truss Type
J1533129
J135450 -F06A FLOOR �O"—] Iii-b Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 g&L-13 2005 MiTek Industries,Inc. Thu Oct 27 10:13:41 2005 Page 1
lb- 4x6 2 3x4 11 3
0-6-13 1-2-10 -1-
Scale 1:10.4
7
1x3
6 3x4 4 Simpson THAR1422
0-4-10 2-6-7
0-4-10 0-1-14 0-1-8 4x6 1-9-0 3x4
0-1-8
Plate Offsets(X,Y): [1:Edge,0-1-81,[3:0-1-8,Edgq],17:0-0-0,0-0-01
LOADING(psf) SPACING 2-0-0 CS1 DEFL in (10c) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) 0.00 5 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.06 Vert(TL) 0.00 5 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.27 Horz(TL) -0.00 4 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:28 lb
LUMBER BRACING
TOPCHORD 4 X 2 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 2-6-7 oc puffins, exceIR]
BOTCHORD 4 X 2 SYP No.2 end verticals.
WEBS 4 X 2 SYP No.3 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size) 4=-392/Mechanical,5=1421/0-6-11
Max UpI ift4=446(load case 2),5=-971(load case 4)
Max Grav4=369(load case 4),5=1 421(load case 1)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-6=-8/9,4-7=-362/446,3-7=-361/446,1-2=-274/351,2-3=-274/351
BOTCHORD 5-6=0/0,4-5=-15/12
WEBS 2-5=-161/0,1-5=-873/681,3-5=-562/437
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 446 lb uplift at joint 4 and 971 lb uplift at
joint 5.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
4)CAUTION,Do not erect truss backwards.
5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
LOAD CASE(S) Standard Except:
1)Floor:Lumber Inerease=1.00,Plate Increase=1.00
Uniform Loads(plf)
Vert:4-6=-10,1-3=-100 Truss Design Engineer:Lawrence A.Paine,PE
Concentrated Loads(lb) Florida PE No.21475
Vert:1=-784(F) Builders FirstSource-Florik LLC
4)User defined:Lumber Increase=1.00,Plate Increase=1.00 6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
K REFERENCE PAGE 11111111-7473 BEFORE USE
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be a
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FirstSource
Job �Truss Truss Type city Ply A 53312
J135450 _F06A FLOOR 1 1 �Job Reference(optional) I
Builders First Source,Jacksonville Florida 32244 6.200 e Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:13:412005 Page 2
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Architect/Engineer of Record to verify and approve the loading.
LOAD CASE(S)
Uniform Loads(plf)
Vert:4-6=-6(F),1-3=-12(F)
Concentrated Loads(lb)
Vert:1=642(F)
Truss Design Engineer:Lamence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd..Jacksonville,FL 32244
October 27,2005
A& Warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11101111-7473 BEFORE USE
Design v lid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
a
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss hlBuMm
i designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
regarding FrStSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madisor�,WI 53719
Job russ Truss Type Qty Ply
J1533130
J135450 Ciol JACK 6 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:20 2005 Page 1
-2-0-0 1-0-0 3
2-0-0 1-0-0
Scale:1.5"=1'
2
6.00 r1_2
4
2x4
1-0-0
1-0-0
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.50 Vert(LL) -0.00 2 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 2 >999 180
BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:7 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 1-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 2=277/0-3-8,4=14/Mechanical, 3=-98/Mechanical
Max Horz 2=1 58(load case 5)
Max Uplift 2=-528(load case 5),4=-17(load case 3), 3=-98(load case 1)
Max Grav 2=277(load case 1),4=1 4(load case 1),3=221(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/48,2-3=-73/133
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.57
NOTES
1)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Truss Design Engineer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 52&lor'da PE No.21475
lb uplift at joint 2, 17 lb uplift at joint 4 and 98 lb uplift at joint 3. Builders FirstSource-Florik LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
LOAD CASE(S) Standard October 27,2005
K REFERENCE PAGE 1111111-7473 BEFORE USE
Desig valid for use only with Welk connectors.This design is based only upon parameters shown,and is for an individual building component to be IN
Install dandloadeavertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the LmWlmrs
responsibil try of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
FirstSource
Job Truss Truss Type Qty Ply
J1533131
J135450 CJ01A JACK 3 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:20 2005 Page 1
-2-0-0 1-0-0
2-0-0 1-0-0
Scale 1:10.2
6.00[1-2
2
4
W
Structural sub-fascia beam required. Sub-fascia beam and
its connections to be designed and furnished by others.
0-6-12 1-0-0
0-6-12 0-&4
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.09 Vert(LL) -0.00 2 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.08 Vert(TL) -0.00 2 >999 180
BCLL 10.0 Rep Stress Incr YES W13 0.00 Horz(TL) -0.00 1 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:7 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 1-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 1=52/Mechanical,2=140/0-3-8,4=14/Mechanical,3=2/Mechanical
Max Horz 2=144(load case 5)
Max Uplift 1=-84(load case 5),2=-146(load case 5),3=-17(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-17/64,2-3=-24/0
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.24
NOTES
1) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C; partially; MWFRS gable end zone and C-C Exterior(2)zone; cantilever left exposed ; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for
members and forces,and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi D E er:Lawrence A.Paine,PE
3) Provide mechanical connection(by others) of truss to bearing plate capable of withstanding 84TOu" e534no.ng"ne
fforida PE N 214-75
uplift at joint 1, 146 lb uplift at joint 2 and 17 lb uplift at joint 3. Builders FirstSouxce-norida6 LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
LOAD CASE(S) Standard October 27,2005
A Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
look 1&rs
Design valid for use only with MiTek connectors.This design is based only upon parameters shown and is for an individual building component to be
Install d and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
a oul
designe.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
r garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
a : MFirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J 135450 CJ01B JACK 1 1 J1 533132
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:20 2005 Page 1
-2-G-0 "_0
2-0-0 1-0-0
Scale 1:10.2
6.00[1-2
2
X
X
4
W
Structural sub-fascia beam required. Sub-fascia beam and
its connections to be designed and furnished by others.
1-0-0
1-0-0
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.09 Vert(LL) -0.00 2 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.01 Vert(TL) -0.00 2 >999 180
BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 1 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) I I Weight:7 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 1-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 1=52/Mechanical,2=140/0-3-8,4=14/Mechanical,3=2/MechanicaI
Max Horz 2=144(load case 5)
Max Uplift 1=-84(load case 5),2=-146(load case 5), 3=-17(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-17/64,2-3=-24/0
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.24
NOTES
1)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi s DesiCn Engineer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 84TA-
uplift at joint 1, 146 lb uplift at joint 2 and 17 lb uplift at joint 3. Florida PE No.21475
Builders FirstSource-Florida,LLC
LOAD CASE(S) Standard 6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
K REFERENCE PAGE 1111111-7473 BEFORE USE
Design valid foruseonlywith MiTek connectors.Thisdesign is based onlyupon pararnstersshown,and isforan individual building component to be .0
'Mrs
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shom is for lateral support of individual mb members only.Additional temporary bracing to insure stability during construction is the OUI&
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofno Drive,Madison,Wl 53719
RrstSource
Job Truss Truss Type oty Ply
J1533133
J135450 CJ02 JACK 6 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:212005 Page I
-2-0-0 3-0-0 i
2-0-0 3-0-0
Scale 1:12.5
6.0 0 F1_2
2
4
2x4
3-0-0
3-0-0
LOADING (ps� SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.53 Vert(LL) 0.02 2-4 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.14 Vert(TL) 0.02 2-4 >999 180
BCLL 10.0 Rep Stress lncr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 13 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 3=28/Mechanical,2=284/0-3-8,4=42/Mechanical
Max Horz 2=254(load case 5)
Max Uplift 3=-87(load case 6), 2=-455(load case 5),4=49(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-59/6
BOTCHORD 2-4=0/0
JOINT STRESS INDEX
2=0.53
NOTES
1) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi To�us Design Engineer Lawnnce A.Paine,PE
3) Provide mechanical connection (by others)of truss to bearing plate capable of withstanding 87 ffori&PE No.21475
uplift at joint 3,455 lb uplift at joint 2 and 49 lb uplift at joint 4. Builien FirstSource-Florida6 LLC
6550 Roosevelt Biva.Jacksonville,FL 32244
LOAD CASE(S) Standard October 27,2005
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111.7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown and is for an individual building component to be
Installed and loaded vertically.Applicability of design paramenters and proper incorporation ofcomponent is responsibility of building designer-not truss
MACK.".
des.gne.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
-"Source
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 MR51
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job russ Truss Type J1533134
J 135450 CJ02A JACK
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:212005 Page I
-2-�12 -2-0-0 3-0-0
0-0-12 2-0-0 3-0-0 4
Scale 1:12.5
3
6.00[12
2
3x6 3x6 7::-
5
W
0-6-12 3-0-0
0-6-12 2-5-4
Plate Offsets(X,Y): [2:0-0-15,0-1-81
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.89 Vert(LL) 0.02 2-5 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.15 Vert(TL) 0.02 2-5 >999 180
BCLL 10.0 Rep Stress Incr NO W13 0.00 Horz(TL) -0.00 4 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 15 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-0-0 oc purlins.
SLIDER Left 2 X 4 SYP No.3 1-5-0 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 4=-15/Mechanical, 2=381/0-3-8, 5=42/Mechanical
Max Horz 2=254(load case 5)
Max Uplift 4=-56(load case 6), 2=-552(load case 5), 5=49(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-32/71,2-3=-82/0, 3-4=-36/0
BOT CHORD 2-5=0/0
JOINT STRESS INDEX
2=0.28,2=0.23,2=0.24 and 3=0.00
NOTES
1) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; cantilever left exposed ; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for
members and forces, and for MWFRS for reactions specified. Truss Design Engineer:Lawrence A.Paine,PE
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Florida PE No.21475
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 564bilders FintSource-Florida,LLC
uplift at joint 4, 552 lb uplift at joint 2 and 49 lb uplift at joint 5. 6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
Warning-Vertfy design pararnateirs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use onlywith MiTak connectors.This design is based only upon parameters sho,vri,and is for an individual building component to be soft WEB a
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shom is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
res risibillity,of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
po
reg
arding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,NI 53719
First-Source
Job Truss Truss Type aty Ply
J1533134
J135450 CJ02A JACK 3 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:21 2005 Page 2
NOTES
4) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back (B).
5)54.0#concentrated load from a structural sub-fascia beam. Sub-fascia beam and
its connections to be designed and furnished by others.
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/E ng ineer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads(plf)
Vert: 1-4=-54,2-5=-30
Concentrated Loads(lb)
Vert: 1=-54(F)
Truss Design Enigineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design pararnenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
-88 Ouality Standard,DSB-89 Bracing Specification,and HIS-91
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST OFirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Tru s Type y y
J1533135
J 135450 CJ02B JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:212005 Page 1
-2-P;12 -2-0-0 3-0-0
0-0-12 2-0-0 3-0-0 3
Scale 1:12.5
6.00 F1-2
2
4
3x6
3-0-0
3-0-0
LOADING (pso SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 2.0.0 Plates Increase 1.25 TC 0.80 Vert(LL) 0.02 2-4 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.15 Vert(TL) 0.02 2-4 >999 180
BCLL 10.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5�O Code FBC2004/TP12002 (Matrix) Weight: 13 lb
LUMBER BRACING
TOPCHORD 2X4SYPNo.1D TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 3=-1 O/Mechanical, 2=369/0-3-8,4=42/Mechanical
Max Horz 2=254(load case 5)
Max Uplift 3=41(load case 6),2=-582(load case 5),4=-49(load case 3)
Max Grav 3=1 1(load case 3), 2=369(load case 1),4=42(load case 1)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-51/68, 2-3=-76/4
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.31
NOTES
1)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Tniss Design Engineer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 41'1 rida.PE No.21475
uplift at joint 3, 582 lb uplift at joint 2 and 49 lb uplift at joint 4. &�;-FirtS---FI.Ma,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
Waming-Verify design Parameters and READ NOTES ON THIS AND—INCLUDEDMITEK REFERENCE PAGE 1111111-7473 BEFO
OR USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the UUU&M
responsibillity of the ere�ctor,Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specilication,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
- ts
Job Truss Truss Ty e Qty Ply
J1533135
J135450 CJ02B JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:21 2005 Page 2
NOTES
4)48.0#concentrated load from a structural sub-fascia beam. Sub-fascia beam and
its connections to be designed and furnished by others.
5) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back(B).
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/Eng i neer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads(plf)
Vert: 1-3=-54,2-4=-30
Concentrated Loads(lb)
Vert: 1=-48(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstScrarce-Florik LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A'& warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111-7473 BEFOR USE
E
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
ftrs
Installed and loaded vertically, Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
ibillity,of the erector,Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re ponsi
garding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
i FirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onoffio Drive,Madison,WI 53719
'es
Job Truss Truss Type Qty Ply
J135450 CJ03 JACK 4 1 J1533136
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:22 2005 Page 1
-2-0-0 5-0-0
2-0-0 5-0-0 3
Scale 1:16.9
6.0 0 F1-2
2
4
2X4
5-0-0
5-0-0
LOADING (pso SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.53 Vert(LL) 0.14 2-4 >403 240 MT20 244/190
TCDL . 7.0 Lumber Increase 1.25 BC 0.41 Vert(TL) 0.13 2-4 >442 180
BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 19 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 3=102/Mechanical,2=348/0-3-8,4=72/Mechanical
Max Horz 2=352(load case 5)
Max Uplift 3=-219(load case 5),2=-512(load case 5),4=-84(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-167/35
BOTCHORD 2-4=0/0
JOINT STRESS INDEX
2=0.62
NOTES
1)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60. This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi russ Design Engineer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 21�
lb uplift at joint 3, 512 lb uplift at joint 2 and 84 lb uplift at joint 4. Florida PE No.21475
Bailders FirstSaurce-Florida,LLC
LOAD CASE(S) Standard 6550 Foosevelt Blvd.Jacksonvine,Fl.32244
October 27,2005
-7473 BEFORE USE
K REFERENCE PAGE Will
IN
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Instal ed and loaded vertically. Applicability of design paramenters,and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
reg rding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
a
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 baFlrstSource
Truiss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
BmIders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Wairning-Verify design parametons end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
I stall -not truss
n ad and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 FirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job russ Truss Type Qty Ply
J1533137
J135450 EJ01 MONO TRUSS 3 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:22 2005 Page 1
-2-0-0 5-0-0
2-0-0 5-0-0 3
Scale 1:16.9
6.00 F1-2
2
N
4
2x4
5-0-0
5-0-0
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.53 Vi 0.14 2-4 >403 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.41 Vert(TL) 0.13 2-4 >442 180
BCLL 10.0 Rep Stress Incr YES W13 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FBC20041TPI2002 (Matrix) Weight: 19 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-0-0 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 3=102/Mechanical, 2=348/0-3-8,4=72/Mechanical
Max Horz 2=352(load case 5)
Max Uplift 3=-219(load case 5),2=-512(load case 5),4=-84(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-167/35
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.62
NOTES
1) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C; partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed;
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
and for MWFRS for reactions specified.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi russ Design Engineer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 21�
lb uplift at joint 3, 512 lb uplift at joint 2 and 84 lb uplift at joint 4. Florida PE No.21475
Builders FirstSouxce-Florida,LLC
LOAD CASE(S) Standard 6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& Warning-Verify design Porametem and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1011111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the LM
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D.Onofdo Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type Oty Ply
J1533138
J135450 EJ02 MONO TRUSS 9 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:22 2005 Page 1
-2-0-0 5-0-0
2-0-0 5-0-0 4
Scale 1:16.9
6.00 F1-2 3
c�
2
M 3x6
1
2x4
0-6-12 5-0-0
0-6-12 4-5-4
Plate Offsets(X,Y): [2:0-0-15,0-1-8]
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.53 Vert(LL) 0.14 2-5 >403 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.41 Vert(TL) 0.13 2-5 >442 180
BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 4 n/a n/a
BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight:23 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-0-0 oc purlins.
SLIDER Left 2 X 4 SYP No.3 2-5-15 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 4=102/Mechanical,2=348/0-3-8,5=72/Mechanical
Max Horz 2=352(load case 5)
Max Uplift 4=-219(load case 5),2=-512(load case 5),5=-84(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-160/0,3-4=-150/34
BOT CHORD 2-5=0/0
JOINT STRESS INDEX
2=0.27,2=0.22,2=0.23 and 3=0.00
NOTES
1) Wind:ASCE 7-02; 1120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp
C; partially; MWFRS gable end zone and C-C Exterior(2)zone;cantilever left exposed ; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=11.60.This truss is designed for C-C for
members and forces, and for MWFRS for reactions specified. Trws Design Erig;ineer:Lawrence A.Paine,PE
2) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Florida PE No.21475
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 21 Diilders FirstSource-Florida,LLC
lb uplift at joint 4,512 lb uplift at joint 2 and 84 lb uplift at joint 5. 6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
LOAD CASE(S) Standard
Warning-Verlify design pararn*t*rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE NIII-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss i
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
MFirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
�Truss Type Qty ply 1 Job Reference(optional) J1533139
--�EJ03 MONO TRUSS 9
Job uss
J135450
Builders First Source,Jacksonville Florida 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 10:25:08 2005 Page I
-2-0-0 7-0-0
2-0-0 7-0-0 3
Scale 1:20.1
6.0 0 F1-2
2
4
2x4
7-0-0
7-0-0
LOADING(psf) SPACING 2-0-0 CS1 DEFL in (10c) I/defl L/d PLATES GRIP
TCLL 20.0 Plates increase 1.25 TC 0.80 Vert(I-L) 0.57 2-4 >143 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.82 Vert(TL) 0.52 2-4 >157 180
BCLL 10.0 Rep Stress Incir YES WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FBC2004/TP]2002 (Matrix) Weight:26 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.1 D TOP CHORD Structural wood sheathing directly applied or 4-8-6 oc purlins. [P]
BOT CHORD 2 X 4 SYP No.2 BOTCHORD Rigid ceiling directly applied or 6-6-12 oc bracing.
REACTIONS (lb/size) 3=164/Mechanical,2=424/0-3-8,4=102/MechanicaI
Max Horz2=450(load case 5)
Max Uplift3=-351(load case 5),2=-595(load case 5),4=-120(load case 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/49,2-3=-245/58
BOT CHORD 2-4=0/0
NOTES
1)Wind:ASCE 7-02;120mph(3-second gust);h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11;Exp C;partially;MWIFIRS gable end
zone and C-C Exterior(2)zone;porch left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C
for members and forces,and for MWFRS for reactions specified.
2)This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
3)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 351 lb uplift at joint 3,595 lb uplift at joint
2 and 120 lb uplift at joint 4.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
K REFERENCE PAGE Mil-7473 BEFORE US
E
Design valid for use only with MiTek connectors.This design is based only upon parameters shovvn,and is for an individual building component to be
installed d loaded vertically, Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shovwn is for lateral support of individual eb members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Stand rd,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,aMadison,Wl 53719 First
Job Truss Truss Type Qty Ply
J 1533140
J135450 HJ01 JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:23 2005 Page 1
-2-9-15 3-8-15 7-0-14
2-9-15 3-8-15 3-3-15 3
Sc .8
4.24 F11-2
c�
2
4
2x4
7-0-14
7-0-14
Plate Offsets(X,Y): [2:0-0-0,0-0-0]
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.84 Vert(LL) 0.23 2-4 >352 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.34 Vert(TL) 0.19 2-4 >436 180
BCLL 10.0 Rep Stress Incr NO W13 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight:26 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 7-0-14 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 3=182/Mechanical,2=379/0-4-15,4=120/Mechanical,4=120/Mechanical,
4=120/Mechanical
Max Horz 2=326(load case 2)
Max Uplift 3=-355(load case 2),2=-624(load case 2),4=-1 16(load case 2)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/50,2-3=-142/42
BOT CHORD 2-4=0/0
JOINT STRESS INDEX
2=0.43
NOTES
1)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C; partially; MWFRS gable end zone; porch left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60. Truss Design Engineer:Lawrence A.Paine,PE
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Florida PE No.21475
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 355diders FirstSource-Florida,LLC
lb uplift at joint 3,624 lb uplift at joint 2 and 116 lb uplift at joint 4. 6550 Roosevelt Blvd.Jacksonville,FL 32244
4) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back October 27,2005
Co@hued on page 2
Waming-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Will am V
SUffm to
Design valid for use only with MiTel,connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only, Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance -91
re
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB FirstSource
Handling installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
LJob Truss Truss Type Qty Ply J1533140
J135450 HJ01 JACK 1 1 Job R-f-1-10 Inntinn
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 09:10:23 2005 Page 2
LOAD CASE(S) Standard
1) Regular: Lumber Increase=11.25, Plate Increase=11.25
Uniform Loads (plo
Vert: 1-2=-54
Trapezoidal Loads(plf)
Vert:2=-3(F=26, B=26)-to-3=-95(F=-21, B=-21),2=0(F=15,B=15)-to-4=-53(F=-12, B=-12)
Truss Design Engineer:Lawrence A.Pairte,PE
Florida PE No.21475
Btrilders FirstSource-Florida,LLC
6550 Roosevelt Blvd..Jacksonville,FL 32244
October 27,2005
Aj Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE 1111111-7473 BEFORE USE
ik
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer ukWsl
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability dunng construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 FirstSource
Job Truss russ Type Qty Ply
J1533141
J135450 HJ02 JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:23 2005 Page 1
-2-1P-8 -2-9-15 4-0-0 7-0-14
0-G-9 2-9-15 4-0-0 3-0-14 4
So .8
5X8
4.24 F11-2 3
8
c�
9
2
Ll
3X6 3x6
10 7 6 5
1 2x4 11 3x6—
2x4 7x10
0-9-15 7-0-14
0-9-15 6-2-15
Plate Offsets(X,Y): [2:0-0-4,Edge], [2:2-5-12,0-1-8], [3:0-2-6,0-2-8], [6:0-1-7,0-1-81
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.52 Vert(LL) 0.03 6-7 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.26 Vert(TL) 0.02 6-7 >999 180
BCLL 10.0 Rep Stress I ncr NO WB 0.17 Horz(TL) -0.01 5 n/a n/a
BCDL 5.0 Code FBC2004ITP[2002 (Matrix) Weight:48 lb
LUMBER BRACING
TOPCHORD 2X4SYPNo.1D TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 6-0-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 7-8-9 oc
LBR SCAB 1-3 2 X 4 SYP No.1 D one side bracing.
SLIDER Left 2 X 4 SYP No.3 3-2-2
REACTIONS (lb/size) 4=178/Mechanical, 2=883/0-5-11,5=287/Mechanical
Max Horz 2=351(load case 2)
Max Uplift 4=-244(load case 2),2=-1 150(load case 2), 5=-368(load case 2)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-47/104, 2-9=-593/563, 8-9=-581/558, 3-8=-522/553, 3-4=-74/45
BOTCHORD 2-1 0=-616/449,7-1 0=-616/449,6-7=-616/449, 5-6=0/0
WEBS 3-6=-498/684, 3-7=-259/232
JOINT STRESS INDEX
1 =0.00, 1 =0.00,2=0.16,2=0.00,2=0.16,2=0.16,2=0.26, 3=0.74, 3=0.00,6 0.18 and 7 0.16
NOTES
1)Attached 7-4-2 scab 1 to 3, back face(s)2 X 4 SYP No.1 D with 1 row(s)of 0.131"xY Nails spaMds Design Engineer:Lawrence A.Paine,PE
9"o.c,except:starting at 2-3-2 from end at joint 1, nail 1 row(s)at 4 o.c.for 2-4-9. Florida PE No.214'75
2) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; &0ders FirstSource-FlorHa,LLC
C; partially; MWFRS gable end zone;cantilever left exposed ; porch left and right exposed; 6550 Roosevelt Blvd.Jacksonville,FL 32244
Lumber DOL=1.60 plate grip DOL=1.60. October 27,2005
§b&W4WMrp@6%a,ssumed to be SYP No.2 crushing capacity of 565.00 psi
Waming-Verily d*sIgn paraimeteirs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Nt111&rS
Instal ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re -91
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB OFimt
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719
Job russ Truss Type aty Ply
J1533141
J135450 HJ02 JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 09:10:23 2005 Page 2
NOTES
4) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 244 lb uplift at joint 4, 1150 lb uplift
at joint 2 and 368 lb uplift at joint 5.
5) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back(B).
6) 107.0#concentrated load from a structural sub-fascia beam. Sub-fascia beam and
its connections to be designed and furnished by others.
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/E ngi neer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Concentrated Loads(lb)
Vert: 1=-107(F)
Trapezoidal Loads(plo
Vert: 1=-54-to-2=-1 03(F=-49),2=-95(F=-41)-to-9=-1 OO(F=-46),9=-54-to-4=-1 36(F=-82),2=-37(F=-7)-to-1 0=-39(F=-9)'
1 0=-30-tcl-5=-76(F=-46)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Bilile'll rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
K REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be ft. .0
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
espons
r lbillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
1 , 1 ;3IS"ource
i garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handli
nginstallingand Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,W153719
Job russ Truss Type Qty Ply
J 1533142
J135450 HJ03 JACK I I
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:24 2005 Page 1
-2-ilp:8 -2-9-15 4-0-0 7-0-14
0-0-9 2-9-15 4-0-0 3-0-14
S .8
5X8
4.24 F1—2 3
8
2
Ll
3x6 3x6
10 7 6 5
2x4 11 3x6
2x4 7x10
Simpson SUR/1-24
0-9-15 7-0-14
0-9-15 6-2-15
Plate Offsets(X,Y): [2:0-0-4,Edgej, [2:2-5-8,0-1-8], [3:0-2-10,0-2-8], [6:0-1-7,0-1-8]
LOADING (ps� SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.61 Vert(LL) 0.04 6-7 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.27 Vert(TL) 0.03 6-7 >999 180
BCLL 10.0 Rep Stress Incr NO WB 0.21 Horz(TL) -0.01 5 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:48 lb
LUMBER BRACING
TOPCHORD 2X4SYPNo.1D TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 6-0-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 6-10-3 oc
LBR SCAB 1-3 2 X 4 SYP No.1 D one side bracing.
SLIDER Left 2 X 4 SYP No.3 3-2-2
REACTIONS (lb/size) 4=1 83/Mechanical, 2=893/0-5-11,5=298/Mechanical
Max Horz 2=351(load case 4)
Max Uplift 4=-300(load case 2),2=-1 315(load case 2), 5=-462(load case 4)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-62/104, 2-9=-614/733,8-9=-602/725, 3-8=-542/711, 3-4=-88/46
BOTCHORD 2-10=-761/468,7-10=-761/468,6-7=-761/468,5-6=0/0
WEBS 3-6=-520/845,3-7=-318/238
JOINT STRESS INDEX
1 =0.00, 1 =0.00,2=0.18,2=0.00,2=0.18, 2=0.18,2=0.29,3=0.79, 3=0.00, 6 0.22 and 7 0.17
NOTES
1) Attached 7-4-2 scab 1 to 3, back face(s)2 X 4 SYP No.1 D with 1 row(s)of 0.131"xY Nails spaMds Design Eriij;imer:Lawrence A.Paine,PE
9"o.c.except:starting at 2-3-2 from end at joint 1, nail 1 row(s)at 4 o.c.for 2-4-8. Florida PE No.21475
2) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exotlers FirstSource-Florik LLC
C; partially; MWFRS gable end zone; cantilever left exposed; porch left and right exposed; 6550 Foosevelt Blvd.JacksonviRe,Fl.32244
Lumber DOL=1.60 plate grip DOL=1.60. October 27,2005
6b&W4�Wi,9fl�@§%;23sumed to be SYP No.2 crushing capacity of 565.00 psi
W..1.9-Verify doslon Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with MiTelk connectors.This design is based only upon parameters shom,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracmg shom is for lateral support of individual eb members only.Additional temporary bracing to insure stability during construction is the
responsib'llity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofro Drive,Madison,Wl 53719 i MFirstSource
Job Truss Truss Type Q y Ply
J1533142
J 135450 HJ03 JACK 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s jul 1-3 200-5 MiTek Industries, Inc. Wed Oct 26 09:10:24 2005 Page 2
NOTES
4) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 300 lb uplift at joint 4, 1315 lb uplift
at joint 2 and 462 lb uplift at joint 5.
5) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back (B).
6) 107.0#concentrated load from a structural sub-fascia beam. Sub-fascia beam and
its connections to be designed and furnished by others.
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/E ng I neer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Concentrated Loads(lb)
Vert: 1=-107(F)
Trapezoidal Loads(plf)
Vert: 1=-54-to-2=-103(F=-49),2=-95(F=-41)-to-9=-100(F=-46),9=-55(F=-1)-to-4=-140(F=-86),
2=-37(F=-7)-to-10=-39(F=-9), 10=-31(F=-1)-to-5=-78(F=-48)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A Naming.Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE ll BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters sho,vn,and is for an individual building component to be 0
Installed and loaded vertically Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shom is fo�lateral support of individual"b members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control.storage.delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type oty Ply
J153314
J135450 HJ04 MONO TRUSS 2 1 �Job Reference(optional) I
Builders First Source,Jacksonville Florida 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:24:55 2005 Page 1
-2-9-15 5-2-5 8-0-0 9-10-
2-9-15 5-2-5 2-9-11 1-10-13
Scale:51: .4
2x4 11
4
4.24 F1-2 2X4
3
2
7 6
5x6 3x6
Simpson SUR/L24
8-0-0 9-10-1 9-lp-13
8-0-0 1-10-1 0-�'12
LOADING(psfI SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.87 Vert(LL) 0.32 2-7 >355 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.52 Vert(TL) 0.27 2-7 >430 180
BCLL 10.0 Rep Stress Incr NO WB 0.21 Horz(TL) -0.01 6 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:52 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. [P]
BOTCHORD 2 X 6 SYP NoAD BOTCHORD Rigid ceiling directly applied or 7-1-0 oc bracing.
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 5=238/Mechanical,2=536/0-5-11,6=403/Mechanir-al
Max Horz2=549(load case 2)
Max Uplift5=-379(load case 2),2=-790(load case 2),6=-585(load case 2)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/54,2-3=-473/354,3-4=-211/0,4-5=-136172
BOTCHORD 2-7=-748/440,6-7=0/0
WEBS 3-7=-503/856,4-7=0/1 79
NOTES
1)Wind:ASCE 7-02;120mph(3-second gust);h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11;Exp C;partially;MWFRS gable end
zone;porch left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60.
2)This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
3)Provide mechanical connection(by others)of truss to bearing plate capable ofwithstanding 379 lb uplift at joint 5,790 lb uplift atjoint
2 and 585 lb uplift at joint 6.
4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
LOAD CASE(S) Standard
1)Regular:Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)i
Vert:1-2=-54
Trapezoidal Loads(plf)
Vert:2=-3(F=25,B=25)-to-5=-1 34(F=-40,B=-40),2=-O(F=l 5,B=1 5)-to-6=-74(F=-22,B=-22)
Truss Design Ertgimer:Lawrence A.Paine,PE
Florida PE No.21475
5,0,1 rs FirstSouxce-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Woming-Verify design parametem and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10111-7473 BEFORE USE
Design valid for use only with Mi-rek connectors,This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
at temporary bracing to insure stability during construction is the
designer.Bracing shown is for lateral support of individual web members only. Addition
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
is -,urce
in,ab ti n quality control,storage,delivery,erection and bracing,consult OST-88 Ouality Standard,DSB-89 Bracing Specification,and HIB-91 FirstSo
ri 0
=n In talc, a;d Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job russ Truss Type Qty Ply
J1533144
J135450 T01 HIP 1 2 Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:25 2005 Page I
-2-0-0 5-0-0 9-11-5 12-7-8 14-10-11 19-10-0 24-10-0 26-10-0
2-0-0 5-0-0 4-11-5 2-8-3 2-3-3 4-11-5 5-0-0 2-0-0
Scale 1:49.3
4 4 6:5: 5x8 2x4 11 5x10 T201-lzz�
6.00 F1-2 5 6
3 8
c�
2 9 c?
3x8 10
3x8
5x8 15 23 24 14 25 26 13 12 27 28 11 3x6
3x6 2x4 11 3x6 2x4 11 5x8 11
3x8
�6-1? 5-0-0 5-%12 9-11-5 14-10-11 19-10-0 24-1 M
0-6-12 4-5-4 0-0-12 4-10-9 4-11-5 4-11-5 5-0-0
Plate Offsets(X,Y): [2:0-1-8,0-2-0], [9:0-7-7,Edgel, (9:0-0-4,Edge]
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.77 Vert(LL) 0.42 12-14 >702 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.48 Vert(TL) 0.37 12-14 >807 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr NO WB 0.35 Horz(TL) -0.12 9 n/a n/a
BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight:253 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 6-0-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-9-5 oc
SLIDER Left 2 X 4 SYP No.3 2-5-15, bracing.
Right 2 X 4 SYP No.3 2-5-15
REACTIONS (lb/size) 2=1937/0-3-8,9=1949/0-3-8
Max Horz 2=1 23(load case 4)
Max Uplift 2=-3257(load case 4),9=-3332(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-3515/5944,3-4=-3449/5953,4-16=-3125/5474, 16-17=-3124/5474,
5-17=-3124/5474, 5-18=-4420/7929, 18-19=-4420/7929, 19-20=-4420/7929,
6-20=-4420/7929,6-21=-4419/7928, 21-22=-4420/7928,7-22=-4420/7928,
7-8=-3474/6112, 8-9=-3540/6102, 9-10=0/49 Tnus Design Engineer:Lawrence A.Paine,PE
BOTCHORD 2-15=-5194/3059, 15-23=-7694/4404,23-24=-7694/4404, 14-24=-7694/4404' Florida PE No.21475
14-25=-7694/4404, 25-26=-7694/4404, 13-26=-7694/4404, 12-13=-7694/4404, B,fld rs FirstSource-Florida,LLC
12-27=-5335/3108,27-28=-5335/3108, 11-28=-5335/3108, 9-1 1=-5290/3081 6550 Roosevelt Blvd.Jacksonville,FL 32244
WEBS 4-15=-1999/1156,5-15=-1483/2786,5-14=-430/266, 5-12=-93/29,6-12=-421/844,
7-12=-2762/1510, 7-11=-778/471
JOINT STRESS INDEX
2=0.90,2 0.78, 2 0.00,3=0.00,4=0.79, 5=0.48, 6=0.33, 7=0.72, 8=0.00,9=0.70,9 0.80, 9=0.00, 9 0.91, 11
=0.33, 12 0.69, 13 0.73, 14=0.33 and 15=0.61 October 27,2005
Continued on page 2
or�oulk all a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building
MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of buildin component to be W11111:�
g designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,VVI 53719 First ource
Job Tr ss Truss Ty e Qty Ply
J1533144
J135450 T01 HIP 1 2 Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:25 2005 Page 2
NOTES
1) 2-ply truss to be connected together with 0.1 31"xY Nails as follows:
Top chords connected as follows:2 X 4- I row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 4-1 row at 0-9-0 oc.
Webs connected as follows: 2 X 4- 1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies, except if noted as front(F)or back(B)face in the LOAD CASE(S)section.
Ply to ply connections have been provided to distribute only loads noted as(F)or(B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp C;partially; MWFRS gable
end zone;cantilever left exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60.
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
8) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 3257 lb uplift at joint 2 and 3332 lb
uplift at joint 9.
LOAD CASE(S) Standard
1) Regular: Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads(plo
Vert: 1-4=-54,4-7=-54, 7-10=-54, 2-9=-30
Concentrated Loads (lb)
Vert:4=-172(F)7=-177(F) 13=-42(F) 15=-299(F) 1 1=-310(F) 16=-48(F) 17=-48(F) 18=-48(F) 19=-48(F)20=-48(F)
21=-48(F)22=-48(F)23=-42(F)24=-42(F) 25=-42(F)26=-42(F)27=-42(F)28=-42(F)
Truss Design Erig�mer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE owift oil a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be EL.WE a
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
LWOW"
I designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regardi -88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 FirstSource
ng fabrication,quality control,storage,delivery,erection and bracing,consult QST
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job russ Truss Type Qty P11
J 1533145
J135450 7T02 HIP 1 1 Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:25 2005 Page 1
-2-0-0 7-0-0 12-5-0 17-10-0 24-1 G-0 26-10-0
2-0-0 7-0-0 5-5-0 5-5-0 7-0-0 2-0-0 1
Scale=1:49.3
7x14 MT20H
8x14 MT18H z�
3x6
4 5 6
6 6.00 F1—2 —
00 1 2
7
3 8
A
2 E 7
8x12 3x6 1�� 3x6-1�- 8
x,
3x6 11 10 9 5x6
3x6 4x6 3x6
24-10-0
0-6-12 6-5-4 10-10-0 7-0-0
Plate Offsets(X,Y): [2.�0-2-1,0-5-21, [4:0-6-3,Edgel, L6:0-6-3,Edge],[7:0-3-0,0-2-91
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.94 Vert(LL) 0.42 9-11 >702 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.31 Vert(TL) 0.37 9-11 >792 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.24 Horz(TL) -0.06 7 n/a n/a MT18H 244/190
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 137 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2*Except* TOPCHORD Structural wood sheathing directly applied or
4-6 2 X 4 SYP No.1 D 2-2-0 oc purlins.
BOTCHORD 2 X 6 SYP No.1 D BOTCHORD Rigid ceiling directly applied or 4-5-1 oc
WEBS 2 X 4 SYP No.3 bracing.
SLIDER Left 2 X 4 SYP No.3 3-7-6
REACTIONS (lb/size) 7=1150/0-3-8,2=1150/0-3-8
Max Horz 2=-149(load case 6)
Max Uplift 7=-1 607(load case 6),2=-1 607(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/52,2-3=-1 806/3531,3-4=-1 710/3543,4-5=-1 554/3368,5-6=-1 559/3378,
6-7=-1810/3552,7-8=0/52
BOTCHORD 2-11=-2815/1535, 10-11=-3168/1755, 9-1 0=-3168/1755,7-9=-2825/1540
WEBS 4-11=-984/472, 5-11=-339/504, 5-9=-341/500,6-9=-974/477
JOINT STRESS INDEX
2=0.50, 2=0.62,2=0.62,2=0.28, 3=0.00,4=0.98, 5=0.34,6=0.91,7=0.90,9=0.34, 10 0.72 and 11 0.34
NOTES Truss Design Engineer:Lawrence A.Paine,PE
1) Unbalanced roof live loads have been considered for this design. Florida PE No.21475
2) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11; Ow;Vers FirstSouxce-Florik LLC
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; cantilever left exposed ; porch kffO Roosevelt Blvd.Jacksonville,FL 32244
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. This truss is designed for C-C for October 27,2005
CofflW0kr&rppggf&ryes,and for MWFRS for reactions specified.
K REFERENCE PAGE NIII-7473 REFORE USE
Design valid for use only with MiTek connectors This design is based only upon parameters sho�,and is for an individual building component to be
Insta ad and loaded vertically.Applicability of design paramenters,and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shom is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FrStSource
Job Truss Truss Type Qty Ply
J1533145
J135450 T02 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:25 2005 Page 2
NOTES
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated.
5) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1607 lb uplift at joint 7 and 1607 lb
uplift at joint 2.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blva.Jacksonville,FL 32244
October 27,2005
A Warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE JIM
gill a —
Design valid for use only with Mi7ek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically, Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not tnuss
12U
designer.Bracing shown is for lateral suppon of individual web members only.Additional temporary bracing to insure stability during construction is the
r es
ponsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
MFrstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Oncfrio Drive,Madison,WI 53719
Job Truss Truss Type ty Ply
J135450 T03 HIP 1 1 J1533146
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:26 2005 Page 1
-2-0-0 4-9-4 9-0-0 15-10-0 1 20-0-12
24-10-0 26-10-0
2-0-0 4-9-4 4-2-12 6-10-0 4-2-12 4-9-4 2-0-0
Scale 1:49.3
500 MT20H::�
5xl 0 MT20H z�
5 6
6.0 0 Fl-2 3x6
3x6
4
3
2 8
3x8 9
3x6 14 13 12 11 10 5x6
4x10 H 2x4 !I 3x8 M M 2x4 11
0-6-12 4-2-8 4-2-12 6-10-0 4-2-12 4-9-4
Plate Offsets(X,Y): [2:0-2-0,0-0-5], [2:0-0-4,Edge], [8:0-1-10,Edge)
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.86 Vert(LL) 0.38 11-13 >783 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.43 Vert(TL) 0.33 11-13 >885 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.31 Horz(TL) -0.11 8 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 132 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 4-6-10 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 3-5-3 oc
SLIDER Left 2 X 4 SYP No.3 2-3-5 bracing.
REACTIONS (lb/size) 2=1150/0-3-8,8=1150/0-3-8
Max Horz 2=-1 69(load case 6)
Max Uplift 2=-1634(load case 5), 8=-1634(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49, 2-3=-1819/3606,3-4=-1736/3621,4-5=-1495/3100,5-6=-1316/2926,
6-7=-1496/3103,7-8=-1832/3646,8-9=0/49
BOTCHORD 2-14=-2923/1553, 13-14=-2923/1553, 12-13=-2306/1313, 11-12=-2306/1313,
10-1 1=-2951/1567,8-10=-2951/1567
WEBS 4-13=-286/730, 5-13=-817/317,6-13=-1 12/118,6-1 1=-836/326, 7-1 1=-304/768,Trws DesignErq;ineer:Lawrence A.Paine,PE
4-1 4=-279/1 12, 7-1 0=-289/1 22 Florida PE No.2 1475
Fbild rs FirstSourre-FlorA LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.81, 2=0.95,2=0.00,2=0.97,3=0.00,4=0.39, 5=0.84, 6=0.82, 7=0.39,8=0.93, 10 0.33, 11 0.34, 12=0.49
13=0.56 and 14=0.33
NOTES
1) Unbalanced roof live loads have been considered for this design.
Continued on page 2 October 27,2005
K REFERENCE PAGE NIII-7473 BEFORE USE
Design valid for use only with MiTelk connectors.This design is based only upon parameters shown and is for an individual building component to dim a
not truss
Insta ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer be
desig r Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
LWIM."
i respon lbillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
i Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type Qty Ply
J1533146
J135450 T03 HIP
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 20b5 MiTek Industries, Inc. Wed Oct 26 09:10:26 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C;partially; MWFRS gable
end zone and C-C Exterior(2)zone; cantilever left exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60.This truss is designed for C-C for members and forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated.
5)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1634 lb uplift at joint 2 and 1634 lb
uplift at joint 8.
LOAD CASE(S) Standard
Tnus Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
50d rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.JacicsonvMe,FL 32244
October 27,2005
�A�& Wanning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use onlywith Mi7ek connectors.This design is based only upon parameters shown and is for an individual building component to be
i
not truss
I i
Instal ad and loaded vertically. Applicability of design paramenters,and proper incorporation of component is responsibility of building designer-
designer.Bracing shown Is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the i
a
pon ibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
-89 Bracing Specification,and HIB-91
garding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB OFJrstSourclu
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J 135450 T04 HIP J1533147
L... Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:26 2005 Page I
-2-0-0 5-9-4 11-0-0 1 3-10-0 24-10-0 26-10-0
1 19-0-12
2-0-0 5-9-4 5-2-12 2-10-0 5-2-12 5-9-4 2-0-0
Scale 1:49.3
5X8
5x8 z�
5 6
6.00 F-12
2x4
2x4
4 7
3
2
3x8 9
3x6 13 12 11 10 5x6
6X8 11 3x6 3x6 3x6 3x6
0176-1� 6-5-15 12-5-2 18-4-6 24-10-0
0-&12 5-11-3 5-11-3 5-11-3 6-5-10
Plate Offsets(X,Y): [2:0-2-4,0-0-51, L2:0-0-4,Edgel, [8:0-1-10,Edge]
LOADING (psf) SPACING 2-0-0 CS11 DEFIL in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.81 Vert(LL) 0.30 12-13 >990 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.38 Vert(TL) 0.26 12-13 >999 180
BCLL 10.0 Rep Stress Incr YES WB 0.36 Horz(TL) -0.09 8 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 134 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 4-6-6 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 3-5-5 oc
SLIDER Left 2 X 4 SYP No.3 2-10-3 bracing.
WEBS 1 Row at midpt 5-13, 6-10
REACTIONS (lb/size) 2=1150/0-3-8,8=1150/0-3-8
Max Horz 2=-192(load case 6)
Max Uplift 2=-1657(load case 5), 8=-1657(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-1786/3545,3-4=-1706/3559,4-5=-1699/3699,5-6=-1138/2649,
6-7=-1718/3739,7-8=-1800/3585,8-9=0/49
BOTCHORD 2-13=-2865/1526, 12-13=-1 870/1116, 11-12=-1 867/1115, 10-11=-1 867/1115,
8-10=-2892/1538
WEBS 4-1 3=-255/591,5-1 3=-1 338/552, 5-1 2=-231/21 0,6-1 2=-250/21 6,6-1 0=-1 384/57T!-s Design Engineer:Lawrence A.Paine,PE
7-1 0=-261/606 Florida PE No.21475
Builders FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.88, 2=0.93,2=0.00,2=0.88, 3=0.00,4=0.33, 5=0.87,6=0.88,7=0.36,8=0.91, 10 0.50, 11 0.38, 12=0.50
and 13=0.50
NOTES
1) Unbalanced roof live loads have been considered for this design.
Continued on page 2 October 27,2005
K REFERENCE PAGE 11111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be mucim
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofho Drive,Madison,WI 53719
RrStSource ,
Job Truss Truss Ty e Oty Ply
J 1533147
J135450 T04 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:26 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C;partially; MWFRS gable
end zone and C-C Exterior(2)zone;cantilever left exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60.This truss is designed for C-C for members and forces,and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1657 lb uplift at joint 2 and 1657 lb
uplift at joint 8.
LOAD CASE(S) Standard
Tnus Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& warning-verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
not truss
9JU
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer &J"S
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
re ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Firs-DItSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J1533148
J 135450 T05 COMMON 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:27 2005 Page I
-2-0-0 6-5-12 12-5-0 18-4-4 24-10-0
2-0-0 6-5-12 5-114 5-114 6-5-12
Scale 1:46.0
5x8
5
3x6 I-
2x4 2x4
3 4 6
6.00 F1—2
2 7
3x8 10 9 8 3x8
4x6 3x6 4x6
8-5-8 16-4-8 24-1 0-0_
8-5-8 7-11-1 8-&8
Plate Offsets(X,Y): [2:0-0-10,Edge], [7:0-0-10,Edge]
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.49 Vert(LL) 0.06 1 n/r 120 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.39 Vert(TL) 0.11 1 n/r 90
BCLL 10.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.00 7 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 114 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 6-0-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (lb/size) 7=292/24-10-0,2=421/24-10-0, 10=729/24-10-0,8=756/24-10-0
Max Horz 2=249(load case 5)
Max Uplift 7=-276(load case 6),2=-493(load case 5), 1 0=-715(load case 5),
8=-743(load case 6)
Max Grav 7=295(load case 10),2=425(load case 9), 1 0=729(load case 1),8=756(load
case 1)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/48, 2-3=-191/184, 3-4=0/134,4-5=0/158, 5-6=0/158,6-7=-175/179
BOTCHORD 2-1 0=-80/114, 9-1 0=0/272, 8-9=0/272, 7-8=0/1 17
WEBS 3-10=-350/707, 5-10=-221/268, 5-8=-224/276,6-8=-364/745
JOINT STRESS INDEX
2=0.79, 3=0.41,4=0.83, 5=0.69, 6=0.41,7=0.79,8=0.29, 9=0.16 and 10=0.29
NOTES Truss Design Engineer:Lamence A.Paine,PE
1) Unbalanced roof live loads have been considered for this design. Florida PE No.21475
2) Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; ff4roers FirstSource-Florida,LLC
C;partially; MWFRS gable end zone and C-C Exterior(2)zone; porch left and right exposed; 6550 Roosevelt Blvd.Jacksonville,FL 32244
Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and forces,
CoRW&8 Wa5§_tor reactions specified. October 27,2005
K REFERENCE PAGE Mll-7473 BEFORE USE
Design valid for use only with MiTak connectom.This design is based only upon parameters shown and is for an individual building component to be
Installed and loaded vertically, Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
I
designer.Bracing shown is for ateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector, Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type Qty Ply
J1533148
J135450 T05 COMMON 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:27 2005 Page 2
NOTES
3) Gable requires continuous bottom chord bearing.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 276 lb uplift at joint 7,493 lb uplift
at joint 2,715 lb uplift at joint 10 and 743 lb uplift at joint 8.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida6 LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
I A& Warning-Verify design perametem and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 101111-7473 BEFORE USE
Design valid for use only with MlTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Inst lied and loaded vertically. Applicability of design peramenters and proper incorporation of component is responsibility of building designer
a ImAW"s
designer,Bracing shown is for lateml support of individual web members only.Additional temporary bracing to insure stability during construction is the
i responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
-1-Source
-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST MFiml
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J135450 T06 COMMON 2 1 J1533149
Job Reference(optional)
Bu ilders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:27 2005 Page 1
1
-2-0-0 6-5-12 12-5-0 18-4-4 24-10-0
2-0-0 6-5-12 5-11-4 5-11-4 6-5-12
Scale 1:46.0
4x10
5
4x6
2x4
4 2x4
3 6
6.0 0 FI-2
Simpson HTU26
2 7
3x8 10 9 8 3x8 Zz
3x6 3x6 3x6
8-5-8 16-4-8 24-10-0
B-5-8 7-11-1 8-5-8
Plate Offsets(X,Y): [2:0-0-10,Edge], [4:0-3-0,Edge], [7:0-0-10,Edge].
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.69 Vert(LL) 0.22 7-8 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.51 Vert(TL) -0.30 7-8 >976 180
BCLL 10.0 Rep Stress Incr YES WB 0.67 Horz(TL) 0.05 7 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 114 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 4-1-7 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-6-14 oc
bracing.
REACTIONS (lb/size) 7=1026/Mechanical,2=1156/0-3-8
Max Horz 2=249(load case 5)
Max Uplift 7=-937(load case 6), 2=-1 169(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-1 754/1872,3-4=-1 570/1809,4-5=-1 559/1831,5-6=-1 593/1892,
6-7=-1764/1937
BOTCHORD 2-10=-1477/1497,9-10=-808/1018,8-9=-808/1018,7-8=-1552/1526
WEBS 3-1 0=-316/658, 5-1 0=-589/616, 5-8=-685/650,6-8=-334/703
JOINT STRESS INDEX
2=0.92, 3=0.40,4=0.94, 5=0.62, 6=0.40,7=0.92,8=0.48,9=0.37 and 10=0.48
NOTES
1) Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; ff*s Design Engineer Lawrence A.Paine,PE
C; partially; MWFRS gable end zone and C-C Exterior(2)zone; Lumber DOL=1.60 plate grip Florida PE No.21475
DOL=1.60.This truss is designed for C-C for members and forces,and for MWFRS for reacticiftilders FirstSource-Flori4 LLC
specified. 6550 Roosevelt Blvd.Jacksonville,Fl,32244
3)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi October 27,2005
Continued on page 2
-7473 BEFORE USE
EK REFERENCE PAGE N11I
milk a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
i Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofdo Drive,Madison,WI 53719
FrstSource
Job Truss russ Type Qty Ply
J1533149
J135450 T06 COMMON 2 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:27 2005 Page 2
NOTES
4) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 937 lb uplift at joint 7 and 1169 lb
uplift at joint 2.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.2147.5
BOA rs FirstSoune-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Inst lied and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not tr-uss
a WHOM
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
1 responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
FirstSource
1: Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J135450 T07 HIP 1 2 Job Reference(optional) J1533150
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek'Industries, Inc. Wed Oct 26 09:10:28 2005 Page 1
27-10-15
2-0-0 5-0-0 17-6-0 24-10-12 21-10-15
10-1-4 1 .30-0-0 35-G-0 37-0-0
2-0-0 5.0-0 5-1-4 7-4-12 7-4-12 1-0-3 2-0-0 2-1-1 5-0-0 2Z�Ve 1:66.5
700 5x8 7x14 TNHz�
2x4 11 3x1 2 MT1 8H 2x4 11
7x14 T20HL
6.00 F12 0x411
3 4 5 6 7 iiB
2 9
c�
LE L c?
3x6
17 16 15 14 13 12 20 21 11 54
2x4 11 5x8 5x6 2x4 11 5x6 6x8 2x4 I I
5-0-0 10-1-4 17-6-0 24-10-12 29-11-11 3PP-0 35-0-0
5-0-0 5-1-4 7-4-12 7-4-12 5-0-15 0-0-5 5-0-0
Plate Offsets(X,Y): [2:0-2-12,0-1-81, [8:0-6-3,Edge], [9:0-3-0,0-2-91
LOADING (pso SPACING 2-0-0 CS1 DEFL in (loc) I/defI L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.97 Vert(I-L) 0.76 12-14 >548 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.58 Vert(TL) -0.71 12-14 >590 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr NO W13 0.68 Hor-z(TL) -0.11 9 n/a n/a MT18H 244/190
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 391 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 6 SYP No.1 D 4-0-1 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 5-10-6 oc
bracing.
REACTIONS (lb/size) 2=2084/0-3-8,9=3026/0-3-8
Max Horz 2=126(load case 4)
Max Uplift 2=-2010(load case 4), 9=-3372(load case 5)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/52,2-3=-3928/3954, 3-4=-6193/6532,4-5=-6193/6532, 5-6=-9129/10118,
6-7=-9129/10118, 7-18=-9129/10118, 18-19=-9129/10118, 8-19=-9129/10118,
8-9=-6038/6876, 9-10=0/52
BOTCHORD 2-17=-3431/3446, 16-17=-3432/3456, 15-16=-9188/8736, 14-15=-9188/8736,
13-14=-9188/8736, 12-13=-9188/8736, 12-20=-6030/5357,20-21=-6030/5357,
11-21=-6030/5357,9-11=-6009/5334
WEBS 3-17=-1 9/174,3-16=-3340/3083,4-16=-344/577, 5-16=-2711/3047,5--14=-1 1/28A7"Design Engineer:Lawrence A.Paine,PE
r
5-12=-1 117/449,7-12=-371/703, 8-12=-4393/4232,8-11=-347/386 rida PE No.21475
Builders FirstSo=e-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jarksonville,FL 32244
2=0.76, 3=0.88,4=0.33, 5=0.59, 6=0.87, 7=0.33, 8=0.95,9=0.88, 11 =0.33, 12 0.89, 13 0.97, 14=0.33, 15
0.91, 16=0.86 and 17=0.33
Continued on page 2 October 27,2005
K REFERENCE PAGE fill BEFORE USE
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be 0
Instal ad and loaded vertically.Applicability of design paramen ers and proper incorporation of component is responsibility of building designer-
I �-Ows
designer.Bracing shown is for lateral support of individual web not truss I
r m members only. Additional temporary bracing to insure stability during construction is the LMN&
ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
garding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
First,-Source
Job Truss russ Type Qty Ply
J1533150
J 135450 T07 HIP 1 2 Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:28 2005 Page 2
NOTES
1) 2-ply truss to be connected together with 0.131"xY Nails as follows:
Top chords connected as follows: 2 X 4- 1 row at 0-9-0 oc.
Bottom chords connected as follows:2 X 6-2 rows at 0-9-0 oc.
Webs connected as follows:2 X 4- 1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.
Ply to ply connections have been provided to distribute only loads noted as (F)or(B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C;partially; MWFRS gable
end zone; Lumber DOL=1.60 plate grip DOL=1.60.
5) Provide adequate drainage to prevent water ponding.
6)All plates are MT20 plates unless otherwise indicated.
7)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
8) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 2010 lb uplift at joint 2 and 3372 lb
uplift at joint 9.
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Architect/Engineer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads(plo
Vert: 1-3=-54, 3-8=-54, 8-10=-54, 2-9=-30
Concentrated Loads(1b)
Vert:8=-1 71(F) 12=-1473(F) 11=-1 32(F) 18=-48(F) 19=-48(F)20=-42(F)21=-42(F)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
�AL warning Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111111-7473 BEFORE USE
spok
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Imrs
i Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
mid&
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re -88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 OFrstSource
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719
Job Truss Truss Type Qty Ply
J135450 T08 HIP 1 1 J1533151
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:28 2005 Page I
-2-0-0 7-0-0 14-0-0 21-0-0 28-G-0 35-0-0 37-
2-0-0 7-0-0 7-0.0 7-0-0 7-0-0 7-0-0 2-0-0
Scale 1:66.5
7x14 MT20H 3x6 7x14 MT20H Z�
M WO MT20H=
6.0 0 ri-2 3 4 5 6 7
c?
A
2
9
5x6
14 13 12 10 5x6
3x6 3x1 0 MT20H 3x6 3x1 0 MT20H 3x6
7-0-0 17-6-0 28-0-0 35-0-0
7-0-0 1 0-M 1 0-15�0 7-0-0
Plate Offsets(X,Y): [2:0-1-10,Edgel,_13:0-6-3,Edge], [7:0-6-3,Edgel,18:0-1-10,Edge]
LOADING (psf) SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.83 Vert(LL) 0.55 12 >763 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.94 Vert(TL) -0.74 10-12 >565 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.39 Horz(TL) 0.17 8 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) I Weight: 160 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-0-5 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 2-2-0 oc
bracing.
WEBS 1 Row at midpt 4-14, 6-10
REACTIONS (lb/size) 2=1577/0-3-8,8=1577/0-3-8
Max Horz 2=146(load case 5)
Max Uplift 2=-1 415(load case 5),8=-1 415(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-2714/2665,3-4=-2374/2566,4-5=-3558/3666,5-6=-3558/3666,
6-7=-2374/2565,7-8=-2714/2665, 8-9=0/49
BOTCHORD 2-14=-2033/2341, 13-14=-3191/3399, 12-13=-3191/3399, 11-12=-3191/3399,
10-1 1=-319113399,8-10=-2033/2341
WEBS 3-14=-574/849,4-14=-1245/1365,4-12=0/256,6-12=0/256,6-10=-1245/1365, T—s Design Engineer:Lawrence A.Paine,PE
7-1 0=-574/849 Florida PE No.21475
Bailders FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.68, 3=0.96,4=0.60, 5=0.90, 6=0.60,7=0.96,8=0.68, 10=0.60, 11 =0.95, 12 0.35, 13 0.95 and 14=0.60
NOTES
1) Unbalanced roof live loads have been considered for this design.
Continued on page 2 October 27,2005
Warning-Verity design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE NIII-7473 BEFORE USE
Now &it a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be a
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only,Additional temporary bracing to insure stability during construction is the WOOL"
responsibillity of the erector,Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding
H I fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIS-91 --l'ource
and]ng Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J1533151
J135450 T08 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:28 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated.
5) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1415 lb uplift at joint 2 and 1415 lb
uplift at joint 8.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
norida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Wonning-Veedy design Parameters end READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be MLXw Bit
Install -not truss &rS
ad and loaded vertically.Applicability of desig�paramenters and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-69 Bracing Specification,and HIB-91
FirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,VVI 53719
Job Truss russ Type Qtv Ply
J135450 T09 HIP 1 1 J1533152
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:29 2005 Page 1
-2-0-0 4-9-4 94)-0 1 14-8-0 20-4-0 1 26-0-0 30-2-12 35-G-0 37:qjg_�
2-0-0 4-9-4 4-2-12 5-8-0 5-8-0 5-8-0 4-2-12 4-9-4 2-0-0
Scale 1:66.5
5X8 3x6
W 4x6 5x8�z
6.00 F11-2
2x4-1 >2x4
3 9
�2 Flag 10
5X6
16 15 14 13 12 5x6
3x8 W 3x6 3x6 3xB
9-0-0 17-6-0 26-0-0 35-0-0
9-0-0 8-6-0 8-6-0 9-0-0
Plate Offsets(X,Y): [2:0-1-10,Edge],[6:0-3-0,Edgel, [10:0-1-10,Edge]
LOADING (psD SPACING 2-0-0 CS1 DEFL in (loc) I/defI L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.72 Vert(LL) 0.39 14 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.72 Vert(TL) -0.44 12-14 >952 180
BCLL 10.0 Rep Stress Incr YES WB 0.68 Horz(TL) 0.14 10 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 177 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-7-6 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-0-1 oc
bracing.
REACTIONS (lb/size) 2=1577/0-3-8, 10=1577/0-3-8
Max Horz 2=169(load case 5)
Max Uplift 2=-1448(load case 5), 10=-1448(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49, 2-3=-2671/2802, 3-4=-2450/2551,4-5=-2173/2422,5-6=-2761/3008,
6-7=-2761/3008, 7-8=-2173/2422, 8-9=-2450/2551,9-1 0=-2671/2802, 10-11=0/49
BOTCHORD 2-16=-2195/2331, 15-16=-2404/2687, 14-15=-2404/2687, 13-14=-2404/2687,
12-13=-2404/2687, 10-12=-2195/2331
WEBS 3-16=-210/460,4-16=-639/793, 5-16=-745/833,5-14=-1 3/188, 7-14=-1 3/188,
7-12=-745/832, 8-12=-639/793,9-12=-210/460
JOINT STRESS INDEX
2=0.71, 3=0.33,4=0.93,5=0.42, 6=0.87,7=0.42, 8=0.93,9=0.33, 10=0.71, 12 0.61, 13 0.97, 14 0.42, 15
0.97 and 16=0.61
Truss Design Engineer:Lawrence A.Paine,PE
NOTES Florida PE No.21475
1) Unbalanced roof live loads have been considered for this design. Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
K REFERENCE PAGE 111111-7473 BEFORE USE �lilw oft Noll 2
Design valid for use only with MiTek connectors.This design is based only upon parameters shown and is for an individual building component to be
Installed and loaded vertically.Appli bility of design paramenters and pmper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for late=support of individual web members only.Additional temporary bracing to insure stability during construction is the IJU
s
i respon ibillity at the erector,Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
--LSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,W1 53719
Fiml! o!M
Job Truss russ Type Qty Ply
J1533152
J135450 T09 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:29 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces,and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1448 lb uplift at joint 2 and 1448 lb
uplift at joint 10.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& Warning-Vertfy doslign Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIS-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
'akrs
I Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss ouil&
I designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
I responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
FirstSource
I Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719
Job Truss Truss Type Qty Ply
J135450 T10 HIP 1 1 :7
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 09:10:29 2005 Page 1
�_�o 5-0-4
2-M 5-94 5-2-12 6-6-0 6-6-0 5-2-12 5-9-4 2-0-0
Scale 11:66.5
5x10 MT2011:-�
WO MT20H zz
3x8
4 5 6
6.00 F1_2
2x4-Z�- 2x4
3 7
2 8
01
5x6 14 13 12 11 10 5x6 zz
4x6 2x4 I I 3x8
3x8 4x6
11-0-0
11-0-0 6-6-0 6-6-0 11-0-0
Plate Offsets(X,Y): 12:0-3-12,Edge], [8:0-3-12,Edge)
LOADING (ps� SPACING 2-0-0 CS1 DEFL in (loc) I/defi L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.77 Vert(LL) -0.39 2-14 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.88 Vert(TL) -0.66 2-14 >629 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.28 Horz(TL) 0.13 8 n/a n/a
BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 180 Ib
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-4-6 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-2-13 oc
bracing.
WEBS 1 Row at midpt 5-14, 5-10
REACTIONS (lb/size) 2=1577/0-3-8,8=1577/0-3-8
Max Horz 2=192(load case 5)
Max Uplift 2=-1 478(load case 5),8=-1478(load case 6)
FORCES (1b)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-2615/2810,3-4=-2306/2450,4-5=-2021/2345,5-6=-2021/2345,
6-7=-2306/2450, 7-8=-2615/2810, 8-9=0/49
BOTCHORD 2-14=-2189/2287, 13-14=-1947/2289, 12-13=-1947/2289, 11-12=-194712289,
10-11=-1947/2289,8-10=-218812287
WEBS 3-14=-324t651,4-14=-5151687, 5-14=-469/530,5-12=0/110, 5-10=-469/530, Truss Design Erigimer:Lwvrence A.Pairke,PE
6-10=-515/687, 7-10=-324/651 Florida PE No.21475
Builders FirstSource-Flori4 LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.85, 3=0.35,4=0.75,5=0.56,6=0.75,7=0.35,8=0.85, 10=0.56, 11 =0.92, 12 0.33, 13=0.92 and 14=0.56
NOTES
1) Unbalanced roof live loads have been considered for this design.
October 27,2005
Continued on page 2
Warning-Verity design parameters and READ NOTES ON THIS AND INCLUDED NITER REFERENCE PAGE Mll-7473 BEFORE USE
�oft Nib a
Design valid for use only.ith MfTsk conhectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
1 designer.Bracing shown is for lateral support of individual web members only-Additional temporary bracing to insure stability during construction is the
responsibillity of the a ctor.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
quality control,storage,delivery,erection and bracing,consult QST S t
garding fabrication, Fir,--,,Source
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J1533153
J135450 T10 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:29 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1478 lb uplift at joint 2 and 1478 lb
uplift at joint 8.
LOAD CASE(S) Standard
Truss Design Engimer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A& Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE al a
Desig valid for use only with MiTek connectors,This design is based only upon parameters shown,and is for an individual building component to be IN
in
Instal d and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss BUNK".
a
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
r:sonsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
r P FirstSource
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-86 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,VVI 53719
Job Truss Truss Type Qty Ply
J1533154
J135450 T11 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:30 2005 Page 1
2-0-0 1 6-9-4 13.0-0 17.6-0 22-0-0 28-2-12 35-0-0 37-0-0_�
2-0-0 6-9-4 &-2-12 4-6-0 4-6-0 6-2-12 6-9-4 2-0-0
Scale 1:66.5
5x10 MT2011:�� 5x10 MT20H z�
3x6
4 5 6
RR
6.00 Fj_2 6x8 6x8
3 7
2 8
9
4x6 4X6:Z�
15 14 13 12 11 10
2x4 3x6 3x8 2x4 I I
3x8 3x6
6-9-4 13-0-0 22-0-0 28-2-12 35-G-0
6-9.4 6-2-12 9-0-0 &2-12 15-9-4
Plate Offsets(X,Y): [2:0-3-4,0-0-11], [3:0-4-0,Edge], [7:0-4-0,Edge], [8:0-3-4,0-0-11
LOADING (pso SPACING 2-0-0 CS1 DEFIL in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.81 Vert(LL) 0.29 12-13 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -0.45 12-13 >924 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.13 8 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 187 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-6-4 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-3-7 oc
bracing.
REACTIONS (lb/size) 2=1577/0-3-8,8=1577/0-3-8
Max Horz 2=-215(load case 6)
Max Uplift 2=-1504(load case 5), 8=-1504(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-2692/2768, 3-4=-2114/2341,4-5=-1833/2251,5-6=-1833/2251,
6-7=-2114/2341,7-8=-2692/2768,8-9=0/49
BOTCHORD 2-15=-2134/2324, 14-15=-2134/2324, 13-14=-213412324, 12-13=-1 521/1898,
11-12=-2134/2324, 10-11=-2134/2324,8-10=-2134/2324
WEBS 3-15=0/1 94, 3-13=-578/819,4-13=-490/606,5-13=-255/318, 5-12=-255/318,
6-12=-490/606, 7-12=-578/819,7-1 0=0/1 94
JOINT STRESS INDEX
2=0.85, 3=0.90,4=0.72, 5=0.41, 6=0.72,7=0.90,8=0.85, 10=0.33, 11 =0.86, 12 0.59, 13 0.59, 14 0.86 and
15=0.33
Truss Design Engineer:Lawrence A.Paine,PE
NOTES Florida PE No.21475
1) Unbalanced roof live loads have been considered for this design. Builders FirstSource-Florik LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
Warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE P GENIII-7473 BEFORE USE
oil a
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Insta ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
ig
des ner.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
Mponsibillity of the erector,Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofdo Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type Qty Ply
J1533154
J135450 T11 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:30 2005 Page 2
NOTES
2) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C; partially; IVIWFRS gable
end zone and C-C Exterior(2)zone;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated.
5) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1504 lb uplift at joint 2 and 1504 lb
uplift at joint 8.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
50d rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A Waming-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer
des Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
igner
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
FirstSource
�i Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofdo Drive,Madison,VVI 53719
Job Truss Truss Type Qty Ply
J135450 T12 HIP 2 1 J1533155
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:30 2005 Page 1
54-5 10-2-2 15-0-0 20-0-0 1 24-9-14 29-7-11 37-Q
1 35-0-0
2-0-0 5-4-5 4-9-14 4-9-14 5-0-0 4-9-14 4-9-14 5-4-5 2-0-0
Scale 1:66.5
5X8 7::� 5X8 z�
6 7
2x-4 III 9x4 11
2x4 4x6 5 8 4x6--
6.00 F1-2 4 9
2x4 I-
3 10
I 21i
5x6 17 16 15 14 13 5x6
3x8= 3x6— 3x6 3x6 3x8
10-2-2 17-6-0 24-9-14 35-0-0
10-2-2 7-3-14 7-3-14 10-2-2
Plate Offsets(X,Y): [2:0-1-10,Edge], L4:0-3-0,Edgel, [9:0-3-0,Edge], [11:0-1-10,Edge]
LOADING (ps� SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.64 Vert(LL) 0.30 15-17 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.50 11-13 >837 180
BCLL 10.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.11 11 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 195 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-6-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-2-0 oc
bracing.
WEBS 1 Row at midpt 6-17, 7-13
REACTIONS (lb/size) 2=1577/0-3-8, 11=1577/0-3-8
Max Horz 2=-238(load case 6)
Max Uplift 2=-1 528(load case 5), 1 1=-1 528(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-2646/2875, 3-4=-2367/2548,4-5=-2303/2561,5-6=-2360/2860,
6-7=-1663/2140,7-8=-2359/2860, 8-9=-2302/2561,9-10=-2367/2548,
10-11=-2646/2875, 11-12=0/49
BOTCHORD 2-17=-2254/2314, 16-17=-1210/1632, 15-16=-1210/1632, 14-15=-1210/1633,
13-14=-1210/1633, 11-13=-2254/2314
WEBS 3-17=-296/581, 5-17=-252/628,6-17=-985/795,6-15=-95/238,7-15=-94/239, Truss Design Engineer:Lawrence A.Paine,PE
7-13=-985/793, 8-13=-252/628, 10-13=-296/581 Florida PE No.21475
Builders FirstSaurce-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.73, 3=0.33,4=0.90,5=0.33, 6=0.68,7=0.68,8=0.33,9=0.90, 10=0.33, 11 0.73, 13=0.81, 14=0.59, 15
0.42, 16=0.59 and 17=0.81
NOTES
1) Unbalanced roof live loads have been considered for this design. October 27,2005
Continued on page 2
A Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shom,and is for an individual building component to be '*a a
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing sho%vn is for lateral support of individual veb members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance xxxonersI,
i regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB�89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofro Drive,Madison,WI 53719 10FirstSource
Job Truss russ Type Qty Ply
J1533155
J135450 T12 HIP 2 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:30 2005 Page 2
NOTES
2) Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1528 lb uplift at joint 2 and 1528 lb
uplift at joint 11.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A Warning-Verify design pararnetem end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Moak all a
i Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be IS
I Insta ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss oullcem
1 designer.Bracing shown is for lateral support of individual welb members only. Additional temporary bracing to insure stability during construction is the
I res
ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
m rding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
9 OFrstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J1533156
J135450 T13 HIP 2 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:31 2005 Page 1
-2-0.0 6-0-5 11-6-2 17-0-0 B-G-? 23-5-14 28-11-11 35-0-0 37-0-9-�
2-0-0 6-0-5 5-5-14 5-5-14 1-0-0 5-5-14 5-5-14 6-0-5 2-0-0
Scale 1:66.5
5x8 2z:
5x8��
6 7
8
2 2x4 2x4
x4
6.00[F-1-2 4 9
3 10
2 11
1 DE 1210i
4x6 18 17 16 15 14 13 4x6 z�
B-94 17-0-0 8-0-? 26-2-12 35-0-0
8-9-4 8-2-12 1-0-0 8-2-12 B-9-4
Plate Offsets(X,Y): [2:0-3-4,0-0-111, [11:0-3-4,0-0-11
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) 0.30 16-18 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.37 16-18 >999 180
BCLL 10.0 Rep Stress Incr YES WB 0.84 Horz(TL) 0.12 11 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 195 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-7-4 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-2-3 oc
bracing.
REACTIONS (lb/size) 2=1577/0-3-8, 11=1577/0-3-8
Max Horz 2=-261(load case 6)
Max Uplift 2=-1547(load case 5), ll=-1547(load case6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49, 2-3=-2672/2864, 3-4=-2453/2696,4-5=-2384/2715,5-6=-1728/2130,
6-7=-1493/2046,7-8=-1728/2130, 8-9=-2384/2715,9-10=-2453/2696,
10-1 1=-2672/2864, 11-12=0/49
BOTCHORD 2-18=-2233/2315, 17-18=-1646/1913, 16-17=-1646/1913, 15-16=-1006/1493,
14-15=-1646/1913, 13-14=-1646/1913, 11-13=-2233M15
WEBS 3-18=-268/597, 5-18=-411/528, 5-16=-637/934,6-16=-648/572, 7-15=-648/572,Tnus Design Engineer:Lawrence A.Paine,PE
8-15=-637/934, 8-13=-411/528, 10-13=-268/597 Florida,PE No.21475
Ebild rs FirstSotarce-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.85,3=0.35,4=0.90, 5=0.54,6=0.85,7=0.85,8=0.54,9=0.90, 10=0.35, 11 0.85, 13 0.45, 14=0.77, 15
0.45, 16=0.45, 17=0.77 and 18=0.45
NOTES
1) Unbalanced roof live loads have been considered for this design.
Continued on page 2 October 27,2005
Warning-Verify design parametors;and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE NIII-7473 BEFORE USE
Design valid for use only with MiTek connectom.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
signs.Bmcing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the ou
de r
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
i regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofdo Drive,Madison,WI 53719 FirstSource
Job Truss Truss Type Qty Ply
ru
J135450 T13 H 7,Ps s 2 1 Job Reference(optional) J 1533156
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:31 2005 Page 2
NOTES
2) Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C; partially; IVIWFRS gable
end zone and C-C Exterior(2)zone; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces,and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4) All plates are 3x6 MT20 unless otherwise indicated.
5) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1547 lb uplift at joint 2 and 1547 lb
uplift at joint 11.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSaurce-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
A'& Warning-Verify d..ion parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111111-7473 BEFORE USE
NONE, ON It
In 110M
Design valid for use only with MiTekconnectors.This design isbasedonlyupon parameters shown,and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
i designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
i re ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
s
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 IoFirstSource
Job T uss russ ype Qty Ply J1533157
J135450 T14 COMMON 8 1 Job Reference(optional)
Builders First Source,JacksonvilW,-Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:31 2005 Page 1
-0-0 6-2-5 11-10-2 1 17-6-0 1 23-1-14 28-9-11 35-0-0 37-0-0
2-0-0 6-2-5 5-7-14 5-7-14 5-7-14 5-7-14 6-2-5 2-0-0
Scale 1:65.4
5x8
6
3x6 3x6--
WO MT20H 5 7 300 MT20H
6.00 F1-2 2x4 4 2x4
3 9
10
2 11
4x6 16 15 14 13 12 4x6 Z�
3x6 M 3x8 3x6 3x6
9-0-4 17-&0 25-11-12 35-0-0
9-0-4 8-5-12 8-5-12 9-0-4
Plate Offsets(X,Y): [2:0-3-0,0-0-11],[10:0-3-0,0-0-11]
LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.77 Vert(LL) 0.31 14-16 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.66 Vert(TL) -0.37 14-16 >999 180 MT20H 187/143
BCLL 10.0 Rep Stress Incr YES WB 0.49 Horz(TL) 0.12 10 n/a n/a
BCDL 5.0 Code FBC2004fTP12002 (Matrix) Weight: 184 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 3-7-2 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 4-2-4 oc
bracing.
WEBS 1 Row at midpt 5-14, 6-14,7-14
REACTIONS (lb/size) 2=1577/0-3-8, 10=1577/0-3-8
Max Horz 2=-266(load case 6)
Max Uplift 2=-1552(load case 5), 10=-1552(load case 6)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-2649/2867, 3-4=-2435/2697,4-5=-2363/2709,5-6=-1699/2114,
6-7=-1 699/2114,7-8=-2363/2709,8-9=-2435/2697,9-1 0=-2649/2867, 10-11=0/49
BOTCHORD 2-16=-2233/2307, 15-16=-1 614/1886, 14-15=-1 614/1886, 13-14=-1 614/1886,
12-13=-1614/1886, 10-12=-2233/2307
WEBS 3-16=-284/626, 5-16=-436/533, 5-14=-635/942,6-14=-1 324/1145,7-14=-635/942ros Design Engineer:Lawrence A.Pabae,PE
7-12=-436/533, 9-12=-284/626 Florida PE No.21475
blild rs FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.85, 3=0.36,4=0.81,5=0.55,6=0.74,7=0.55,8=0.81,9 0.36, 10 0.85, 12 0.45, 13 0.73, 14 0.71, 15
0.73 and 16=0.45
NOTES
1) Unbalanced roof live loads have been considered for this design.
October 27,2005
Continued on page 2
Wairning-Wrify d*sign Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Instal oBullclm
ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of individual web members only, Additional temporary bracing to insure stability during construction is the
responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
FrStSource
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty Ply
J1533157
J135450 T14 COMMON 8 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 09:10:31 2005 Page 2
NOTES
2)Wind-.ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf; Category 11; Exp C; partially; MWFRS gable
end zone and G-C Exterior(2)zone;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces,and for MWFRS for reactions specified.
3)All plates are MT20 plates unless otherwise indicated.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1552 lb uplift at joint 2 and 1552 lb
uplift at joint 10.
LOAD CASE(S) Standard
Trims Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Build rs FirstSource-Florida,LLC
6550 Roosevelt Blv&Jacksonville,FL 32244
October 27,2005
Warning Verity design Parameters and READ NOTES ON T"IS AND INCLUDED MITEK REFERENCE PAGE NIII-7473 BEFORE USE
Design Valid for Use Only With MiTel,connectors.This design is based only upon par-ameters shown,and is for an individual building component to be
Installed and loaded vertically, Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
ou
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
re -89 Bracing Specification,and HIB-91
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB
L����mm�andation ava�ilab)efrom Truss�Plate Institute,583 D'�OnofHo Drive,Madison,Wl 53719 FirstSource
Job Truss Truss Type Qty Ply
J135450 T15 HIP 1 J1533158
2�Job Reference(optional)
Builders First Source,Jacksonville Porida 32244 6.200 a Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:15:33 2005 Page 1
2-1-0 7-0-0 9-8-4 1 14-11-12 20-0-4 25-3-12 28-0-0 1 35-0-0 37-0
2-0-0 7-0-0 2-8-4 5-3-8 5-0-8 5-3-8 2-8-4 7-0-0 2-0-0
Scale 1:66.5
5)14::�
I �2x4 11 5; 3; 2x4 11 6x8 5 1 6 z�
6.00[1-2 1 4 7 8
10
LV
3x6 19 2518 26 17 27 16 28 29 15 14 1330 12
2x4 11 3x8 4x6 2x4 10A2 4x6 3x8 11 3x6
7-0-0 9-8-4 1 14-11-12 20-0-4 25-3-12 28-0-0 35-0-0
7-0-0 2-8-4 5-3-8 5-0-8 5-3-8 2-8-4 7-0-0
LOADING(psf) SPACING 2-0-0 cSI DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.54 Vert(LL) 0.1012-13 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.0912-13 >999 180
BCLL 10.0 Rep Stress Incr NO WB 0.89 Horz(TL) -0.03 10 n/a n/a
BCDL 5.0 Code FBC2004rrPI2002 (Matrix) Weight:417 lb
LUMBER BRACING
TOPCHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purfins. [P]
BOTCHORD 2 X 6 SYP NoAD BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1385/0-3-8,15=5752/0-3-8,10=1771/0-3-8
Max Horz2=149(load case 4)
Max Uplift2=-1780(load case 4),15=-6851(load case 3),10=-2303(ioad case 5)
Max Grav2=11 390(load case 6),15=5752(load case 1),1 0=1 783(load case 7)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/52,2-3=-2283/2829,3-20=-1 831/2434,4-20=-1 831/2433,4-21=-1 831/2434,21-22=-1 831/2434,5-22=-1 831/2434
,5-6=-2300/1985,6-23=-2300/1985,7-23=-2300/1985,7-8=-2300/1985,8-24=-2794/3519,9-24=-2795/3520,
9-1 0=-3182/3748,10-11=0/52
BOTCHORD 2-19=-2367/1961,19-25=-2390/1986,18-25=-2390/1986,18-26=-551/505,17-26=-5511505,17-27=-551/505,
16-27=-551/505,16-28=-551/505,28-29=-551/505,15-29=-551/505,14-15=-2874/2731,13-14=-2874/2731,
13-30=-2874/2731,12-30=-2874/2731,10-12=-3148/2763
WEBS 3-19=-565/604,3-18=-259/429,4-18=-457/903,5-18=-2012/1595,5-16=0/241,5-15=-2999/3722,7-15=-468/841,
8-15=-5602/6466,8-13=-2767/2807,8-12=-612/122,9-12=-637/811
NOTES
1)2-ply truss to be connected together with 0.131"x3"Nails as follows:
Top chords connected as follows:2 X 4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2 X 6-2 rows at 0-9-0 oc.
Webs connected as follows:2 X 4-I row at 0-9-0 oc,Except member 8-13 2 X 4-1 row at 0-4-0 oc.
2)Ali loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced roof live loads have been considered for this design.
4)Wind:ASCE 7-02;120mph(3-second gust);h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11;Exp C;partially;MWFRS gable end
zone;porch right exposed;Lumber DOL=1.60 plate grip DOL=1.60.
5)Provide adequate drainage to prevent water poncling.
6)This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspectionTrws Design Engineer:Lawrence A.Paine,PE
7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1780 lb uplift at joint 2,6851 lff1q*iffaePE No.21475
joint 15 and 2303 lb uplift at joint 10. Buikers FirstSciume-Flori4 LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Continued on page 2
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 BEFORE USE
Design valid for use only with MiTel,connectors.This design is based only upon parameters shown and is for an individual building component to be
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-9
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofro Drive,Madison,At 53719 MFirs-tSource
Job Truss Truss Type oty Ply J7�158
J135450 T15 HIP 2 �Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 e Jul 13 2005 MiTek Industries,Inc. Thu Oct 27 10:15:33 2005 Page 2
Loading has been calculated by the truss manufacturer. It is the responsibility
of the Arch itect/E ng i neer of Record to verify and approve the loading.
LOAD CASE(S) Standard
1)Regular:Lumber lncrease=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-3=-54,3-9=-54,9-11=-54,2-1 0=-30
Concentrated Loads(lb)
Vert:3=-308(B)6=-1 1 O(B)9=-308(B)19=433(B)5=-1 10(B)16=-72(B)13=-3000(F)12=433(B)20=-1 1 O(B)21=-1 1 O(B)22=-1 1 O(B)23=-1 1 O(B)24=-1 1 O(B)25=-72(B)
26=-72(B)27=-72(B)28=-72(B)29=-72(B)30=-72(B)
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
AL warning-v*rffy d*sign Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M1111-7473 BEFORE USE
Design valid for use only with M[Tek connectors.This design is based only upon parameters shown,and is for an individual building component to be
i Instal ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
desig oulicem
ner.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
jbillity
respons of the erector, Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance A.e"%
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719 MF'r ource
SIN
Job Truss Truss Typ Qty Ply
J1533159
J135450 T17 HIP
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:32 2005 Page 1
-2-0-0 4-9-4 9-0-0 1411-12
2-0-0 4-9-4 4-2-12 5-11-12 5-0-8 5-11-12 4-2-12 444 2-0-0
Scale 1:66.5
5x8 5� 2x4 11 5x14 z�:
3x8 3x6=
4 5 6 7 8
6.00 F11-2
2x4 2X4-5-
3 9
4
2 110
3x8 17 16 15 14 113 12 5x8 zz
3x8 3x6 2x4 I I 7x10 3x6 3x6
9-0-0 14-11-12 20-0-4 26-0-0 35-0-0
9-0-0 5-111-12 5-0-8 5-11-12 9-0-0
Plate Offsets(X,Y): [2:0-8-8,0-0-14L 11 0:0-2-6,Edge]
LOADING (psf)I SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.53 Vert(LL) 0.43 10-12 >413 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.55 Vert(TL) 0.37 10-12 >479 180
BCLL 10.0 Rep Stress Incr YES WB 0.90 Horz(TL) 0.02 10 n/a n/a
BCDL 5.0 1 Code FBC2004/TP12002 (Matrix) Weight: 184 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-9-8 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 6-7-0 oc
bracing.
REACTIONS (lb/size) 2=808/0-3-8, 14=1799/0-3-8, 10=547/0-3-8
Max Horz 2=169(load case 5)
Max Uplift 2=-835(load case 5), 14=-1880(foad case 4), 10=-956(load case 6)
Max Grav 2=827(load case 9), 14=1799(load case 1), 10=575(load case 10)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49, 2-3=-1 063/1062,3-4=-812/784,4-5=-684/816, 5-6=-500/615,
6-7=-500/615, 7-8=-501/616,8-9=-263/737,9-1 0=-524/1092, 10-11=0/49
BOTCHORD 2-17=-724/911, 16-17=-81/285, 15-16=-81/285, 14-15=-81/285, 13-14=-180/201,
12-13=-180/201, 10-12=-722/436
WEBS 3-1 7=-260/507,4-1 7=0/1 70,5-1 7=-558/535,5-1 5=011 38,5-14=-1 133/1182, Truss Design Engineer:Lawrence A.Paine,PE
7-14=-316/515,8-14=-957/1629, 8-12=-828/369,9-12=-2801640 Florida PE No.21475
Builders FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,Fl.32244
2=0.72, 3=0.33,4=0.59,5=0.88,6=0.29, 7=0.33,8=0.60, 9=0.33, 10 0.60, 12 0.34, 13 0.15, 14 0.27, 15
0.33, 16=0.15 and 17=0.56
NOTES
1) Unbalanced roof live loads have been considered for this design.
Continued on page 2 October 27,2005
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
rpm mail a
Design valid for use only with MiTak connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsib Ility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
I
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,W 153719 Firs-A-Source
Job Truss Truss Type Qty Ply
J135450 T17 HIP 1 1 J1533159
lJob Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MlTek Industries, Inc. Wed Oct 26 09:10:32 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf;Category 11; Exp C;partially; MWFRS gable
end zone and C-C Exterior(2)zone;porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C
for members and forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 835 lb uplift at joint 2, 1880 lb uplift
at joint 14 and 956 lb uplift at joint 10.
LOAD CASE(S) Standard
Truss Desigyt Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,Fl.32244
October 27,2005
A& wainning-Verify design pairamotom and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10111-7473 BEFORE USE
1 Design valid for use ody wit)MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsib designer.For general guidance
illity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building --'Source
ra
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-69 Bracing Specificzition,and HIB First
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onolno Drive,Madison,Wl 53719
Job Truss Truss Type Qty Ply J1533160
J 135450 T18 HIP 1 1 Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:33 2005 Page 1
-2-0-0 5-9-4 1 11-0-0 17-6-0 24-0-0 1 29-2-12 1 35-0-0 1 37-0-0
2-0-0 1 5-9-4 5-2-12 6-6-0 6-6-0 5-2-12 5-9-4 2-0-0
Scale 1:66.5
5x8
3x6 5X8
4 5 6
6.00 F1_2
2M 2x4
7
3
8
2 9
21- 7r7
3x8 15 14 13 12 11 10 3x.8,=
3x6 3x6 7x10 WO 3x6 3x6
7-9-2 14-11-12 20-0-4 27-2-14 35-0-0
7-9-2 7-2-10 5-0-8 7-2-10 7-9-2
Plate Offsets(X,Y): [2:0-8-4,0-0-10], [8:0-8-4,0-0-10]
LOADING (psg SPACING 2-0-0 CS1 DEFIL in (loc) I/defI L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.53 Vert(LL) 0.23 8-10 >789 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.42 Vert(TL) 0.20 8-10 >912 180
BCLL 10.0 Rep Stress Incr YES WB 0.88 Horz(TL) 0.01 12 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 180 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-11-12 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS (lb/size) 8=499/0-3-8, 12=1 882/0-3-8, 2=773/0-3-8
Max Horz 2=192(load case 5)
Max Uplift 8=-918(load case 6), 12=-1868(load case 5),2=-81 1(load case 5)
Max Grav 8=544(load case 10), 12=1882(load case 1),2=804(load case 9)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-1 029/902, 3-4=-852/834,4-5=-143/192, 5-6=-565/669,6-7=-289/861
,7-8=-468/936,8-9=0/49
BOTCHORD 2-15=-637/858, 14-15=-1 94/438, 13-14=-1 94/438, 12-13=-221/771, 11-12=-1 90/426
, 10-11=-190/426, 8-10=-546/360
WEBS 3-15=-262/582,4-15=-493/529,4-13=-548/755,5-13=-583/676, 5-12=-1 084/125"O�uss Design Engineer:Lawrence A.Paine,PE
6-12=-881/1478,6-1 0=1 199/536,7-1 0=-272/628 Florida PE No.21475
Builders FirstSource-Florida,LLC
JOINT STRESS INDEX 6550 Roosevelt Blvd.Jacksonville,FL 32244
2=0.76, 3=0.35,4=0.67, 5=0.81, 6=0.67,7=0.35,8=0.76, 10=0.42, 11 =0.47, 12 0.40, 13 0.40, 14 0.47 and
15=0.42
NOTES
1) Unbalanced roof live loads have been considered for this design.
October 27,2005
Continued on page 2
Warning-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be
not truss
Installed and loaded vertically.Applicability of design paramenters and proper incorporation of component is responsibility of building designer
designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the ou
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofro Drive,Madison,Wl 53719 -"Source
-89 Bracing Specification,and HIB-91
garding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB OFinst
Job Truss Truss Type Qty Ply
J1533160
J135450 T18 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:33 2005 Page 2
NOTES
2)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf;BCDL=3.Opsf; Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone;porch right exposed;Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C
for members and forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection (by others)of truss to bearing plate capable of withstanding 918 ib uplift at joint 8, 1868 lb uplift
at joint 12 and 811 lb uplift at joint 2.
LOAD CASE(S) Standard
Truss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
BuiMers FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
EK REFERENCE PAGE 1111111-7473 BEFORE USE ff
d is for an individual building component to be
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,an
ion of component is responsibility of building designer-not truss
Installed and loaded vertically.Applicability of design paramenters and proper incorporat
designer,Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
--LSource
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91 First
vailable from Truss Plate Institute,583 D'Onoffio Drive,Madison,Wl 53719
Handling Installing and Bracing Recommendation a
Job Truss Truss Type Qty Ply
J1533161
J 135450 T19 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:33 2005 Page 1
2-0-0 6-9-4 13-0-0 17-&0 22-0-0 28-2-12 35-0-0 37-0-0
2-0-0 6-9-4 6-2-12 4-6-0 4-6-0 6-2-12 6-9-4 2-0-0
Scale 1:6&5
5X8 3x6 5x8
5 6 7
7
5x8
5X8
6.0 0 F1-2
5X8
6 00 5-2 4
5X8
3
9
2 10
-A-
3x6 8- 34,
17 16 15 14 13 12
2x4 I I 3x6 6x8 2x4 I I
6x8 3x6
6-9-4 13-0-0 22-0-0 28-2-12 35-0-0
6-9-4 6-2-12 9-0-0 6-2-12 6-9-4
Plate Offsets(X,Y): [2:0-2-12,0-1-8], [4:0-2-0,0-3-01, [8:0-2-0,0-3-0], [10:0-2-12,0-1-8]
LOADING (ps� SPACING 2-0-0 CSI DEFIL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TIC 0.62 Vert(LL) -0.11 14-15 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.47 Vert(TL) -0.19 14-15 >999 180
BCLL 10.0 Rep Stress Incir YES WB 0.72 Horz(TL) 0.02 14 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 187 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 4 SYP No.2 5-5-7 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
WEBS 1 Row at midpt 6-14
REACTIONS (lb/size) 2=881/0-3-8, 14=1731/15-1-8, 10=285/15-1-8, 12=262/15-1-8
Max Horz 2=215(load case 5)
Max Uplift 2=-944(load case 5), 14=-1432(load case 5), 10=-456(load case 6),
12=-315(load case 6)
Max Grav 2=885(load case 9), 14=1 731(load case 1), 1 0=316(load case 10),
12=360(load case 10)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=0/49,2-3=-1205/1255,3-4=-596/768,4-5=-590/792,5-6=-458/855,
6-7=-1 88/473,7-8=-310/587, 8-9=-312/499,9-1 0=-1 12/245, 10-11=0/48 Truss Design Engineer:Lawrence A.Paine,PE
BOTCHORD 2-17=-860/1005, 16-17=-860/1005, 15-16=-860/1005, 14-15=0/342, Florida PE No.21475
13-14=-170/339, 12-13=-170/339, 10-12=-170/339 Builders FirstSource-Florida,LLC
WEBS 3-15=-613/859, 5-15=-75/209,6-15=-665/710,6-14=-982/1026,7-14=-529/667,65.50 Roosevelt Blvd.Jacksonville,FL 32244
9-14=-362/623, 3-17=0/197,9-12=-154/336
JOINT STRESS INDEX
2=0.68, 3=0.00,4=0.83,5=0.71,6=0.59,7=0.71, 8=0.83,9=0.00, 10=0.68, 12 0.33, 13 0.44, 14=0.30, 15
0.30, 16=0.44 and 17=0.33
Continued on page 2 October 27,2005
i,& Waming-Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Il BEFORE USE
owak sit
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be or ILS. dicim
tall
I Ins ad and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss
designer,Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the ou
WFir--'Source
res
ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
'g
arding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bmcing Specification,and HIB-91
ndling Instafling and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job russ Truss Type Qty Ply
J1533161
J135450 T19 HIP 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries,Inc. Wed Oct 26 09:10:34 2005 Page 2
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind:ASCE 7-02; 120mph (3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp C; partially; MWFRS gable
end zone and C-C Exterior(2)zone; Lumber DOL=1.60 plate grip DOL=1.60.This truss is designed for C-C for members and
forces, and for MWFRS for reactions specified.
3) Provide adequate drainage to prevent water ponding.
4) All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 944 lb uplift at joint 2, 1432 lb uplift
at joint 14,456 lb uplift at joint 10 and 315 lb uplift at joint 12.
LOAD CASE(S) Standard
Truss Design Engimer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
Warning-Verity design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
Design valid for use only with MiTelk connectors.This design is based only upon parameters shown and is for an individual building component to be as
I hi
Installed and loaded vertically. Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss 40UO&Ors
I designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the i
i
responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance 64
regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
FirstSource
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719
Job Truss Truss Type Qty P y
J 1533162
J135450 T20 MONO TRUSS 1 1
Job Reference(optional)
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:34 2005 Page 1
5-0-0 2x4 �1
5-0-0 2
Scale 1:14.8
6.00 F12
F-1,
4x6 4 5 3 Simpson HTU26
0�1-12 2-2-12 4-2-12 5-0-0 M
G-1-12 2-1-0 2-0-0 0-9-4
Plate Offsets(X,Y): [1:0-2-4,0-2-0]
LOADING (ps� SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.52 Vert(LL) 0.07 1-3 >846 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BIC 0.67 Vert(TL) -0.07 1-3 >776 180
BCLL 10.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 n/a n/a
BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight:27 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or
BOTCHORD 2 X 8 SYP No.1 D 5-0-0 oc purlins.
WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or 7-1-5 oc
bracing.
REACTIONS (lb/size) 1=1151/0-3-8, 3=1503/Mechanical
Max Horz 1=227(load case 4)
Max Uplift 1=-1075(load case 4), 3=-1488(load case 4)
FORCES (lb)-Maximum Compression/Maximum Tension
TOPCHORD 1-2=-133/45
BOTCHORD 1-4=0/0,4-5=0/0,3-5=0/0
WEBS 2-3=-127/267
JOINT STRESS INDEX
1 =0.12,2=0.14 and 3=0.08
NOTES
1)Wind:ASCE 7-02; 120mph(3-second gust); h=28ft;TCDL=4.2psf; BCDL=3.Opsf;Category 11; Exp
C; partially; MWFRS gable end zone; Lumber DOL=1.60 plate grip DOL=1.60.
2)All bearings are assumed to be SYP No.2 crushing capacity of 565.00 psi Truss Design Erigimer:Lawrence A.Paine,PE
3) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1 ffbrida PE No.21475
lb uplift at joint I and 1488 lb uplift at joint 3. Blild rs FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
Continued on page 2 October 27,2005
Warning-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111111-7473 BEFORE USE
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component to be IN
Installed and loaded vertically.Applicability of design pararnenters and proper incorporation of component is responsibility of building designer-not truss
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the Lmn&rs
'ponsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance
r regarding fabrication,quality control,storage,delivery,erection and bracing,consult OST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
11 - -Source
Hand ng Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofro Drive,Madison,WI 53719 Fir5l
Job Truss Truss T pe aty Ply
J1533162
J135450 T20 MONO TRUSS 1 1
Job Reference(optio a])
Builders First Source,Jacksonville Florida 32244 6.200 s Jul 13 2005 MiTek Industries, Inc. Wed Oct 26 09:10:34 2005 Page 2
NOTES
4) In the LOAD CASE(S)section, loads applied to the face of the truss are noted as front(F)or back(B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads(pl�
Vert: 1-2=-54, 1-3=-30
Concentrated Loads(lb)
Vert: 1=-265(B)4=-996(B)5=-996(B)
Tniss Design Engineer:Lawrence A.Paine,PE
Florida PE No.21475
Builders FirstSource-Florida,LLC
6550 Roosevelt Blvd.Jacksonville,FL 32244
October 27,2005
warning-verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111111-7473 BEFORE USE
�A
Desig valid for use only with MiTak connectors.This design is based only upon parameters shown and is for an individual building component to be as 11CIM
,n
Insta edand loaded vertically.Applicalbilityof design paramenters and proper incorporation of component is responsibility of building designer-not truss
bul
designer.Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the
responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer,For general guidance
regarding fabrication,quality control,storage,delivery,erection and bracing,consult QST-88 Quality Standard,DSB-89 Bracing Specification,and HIB-91
Handling Installing and Bracing Recommendation available from Truss Plate Institute,583 D'Onofrio Drive,Madison,Wl 53719 hlFirstSource
Symbols Numbering System General Safety Notes
PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property
3/�' *Center plate on joint unless Damage or Personal Injury
dimensions indicate otherwise. I. Provide copies of this truss design to the
Dimensions are in inches.Apply building designer,erection supervisor,property
plates to both sides of truss and owner and all other interested parties.
securely seat.
J2 J3 J4 2. Cut members to bear tightly against each
C2 TOP CHORDS C3 other.
J5 3. Place plates on each face of truss at each
0 joint and embed fully.Avoid knots and wane
cl� 0 at joint locations.
0
0
4. Unless otherwise noted,locate chord splices
CI- C)
0 CL at 1A panel length (±6"from adjacent joint.)
\L
LC C1 tC6 0 nless otherwise noted,moisture content of
For 4 x 2 orientation,locate BOTTOM CHORDS lumber shall not exceed 19%at time of fabrication.
plates 1/8"from outside edge A J8 J7 J6
of truss and vertical web. 6. Unless expressly noted,this design is not
applicable for use with fire retardant or
preservative treated lumber.
*This symbol indicates the
required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Comber is a non-structural consideration and
connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator.General
FARTHEST TO THE LEFT. practice is to camber for dead load deflection.
WEBS ARE NUMBERED FROM LEFT TO RIGHT 8. Plate type,size and location dimensions
PLATE SIZE shown indicate minimum plating requirements.
The first dimension is the width 9. Lumber shall be of the species and size,and
4 x 4 perpendicular to slots.Second in all respects,equal to or better than the
dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified.
to slots.
BOCA 96-31,96-67 10.Top chords must be sheathed or purlins
ICBO 3907,4922 provided at spacing shown on design.
11.Bottom chords require lateral bracing at 10
LATERAL BRACING SBCCI 9667,9432A ft.spacing,or less,if no ceiling is installed,
Indicates location of required WISC/DILHR 960022-W,970036-N unless otherwise noted.
continuous lateral bracing. NER 561 12.Anchorage and/or load transferring
connections to trusses are the responsibility of
others unless shown.
13.Do not overload roof or floor trusses with
stacks of construction materials.
BEARING
14.Do not cut or alter truss member or plate
Indicates location of joints at Without prior approval of a professional
which bearings(supports) occur. engineer.
MiTVk-, vszN 15.Care should be exercised in handling,
erection and installation of trusses.
MiTek Engineering Reference Sheet:MIX-7473 0 1993 MiTek(b Holdings,Inc.