Loading...
Permit Mech 126 15th St 2011 , � ' r �..- \� 1 rJ' 1 ' '. CITY OF ATLANTIC BEACH S1� .. _ 800 SEMINOLE ROAD ,. - ' -. ATLANTIC BEACH, FL 32233 _____/) �, INSPECTION PHONE LINE 247 -5814 0319 Application Number 11- 00002981 Date 12/08/11 Property Address 126 15TH ST Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor JONES, MAE THOMPSON DONOVAN HEATING & AIR 126 15TH STREET 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241 -3785 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . 91.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 6/05/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / IS- th eel PERMIT # PROJECT VALUE $ ,.; 3 7S 92 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Duct Systems: Total CFM Seer Rating REPLACEMENT AIR CONDITIONING & HEATING EQUIRED G SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 7-(,,,,0 ARI # 37 a a ( ) Heat Unit Quantity i BTU's Per Unit 2L( o a, REQUIRED Duct Systems: Total CFM l S eer Rating l 3 S REQUI RED FIRE PREVENTION Fire Sprinkler System Quantity Fire Standpipe Quantity 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) (Requires 3 sets of plans) Fire Hose Cabinets Quantity Commercial Hoods (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Q Automobile Lifts Gas Piping Outlets __ Boilers BTU's ALL OM ER GAS PIPING Elevators/Escalators Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces m # Water Heaters Refrigerator Condenser BTU's Solar Collection Systems Tanks Wells (gallons) OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that 1 have read his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified r not. The permit does not give authority to violate the provisions of any other state or local law P regulation construction or the performance of c onstruction. roperty Owners Name t"\ °N HS Phone Number Mechanical Company TaW1OVO (1 t -f i- Ai ti Office Phone 1`1(-37 KS 9 Fax 2�-(1' 3� IS — -o. Address: 315 Lo V� S, City E a% t3esi c k State li. Zip 3 AS1 License Holder (Print): %,311,11;A.44 Ovaovan State Certification/Re ' glstration # C4 C.0 -) b Notarized Signature of License Hol L (,J - / !�, ` _ - '7 Sworn and subscri before me this -i day of 1)e e 1 L Q k- 2011 1; RV pp • ; DERRICK FETNER * a j * MY COMMISSION # EE 090823 S of Notary Public ( 11° 1 EXPIRES: June 7, 2015 � ncRs Bonded Thru Budget Notary Services ....g CERTIFIED,. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3722661 Date: 12/8/2011 Product: Single- Package Heat Pump Air - Source Model Number: PH3ZNB024000AA Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade /Brand name: BRYANT Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 2101240 -2008 for Unitary Air - Conditioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 24000 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 13.50 Heating Capacity(Btuh) @ 47 F: 23800 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 13200 *Ratings followed by an asterisk ( ") indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, A up Air Conditioning, Heating, "WI click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on . am `' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2011 Air- Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129678341103877714