Permit Roof 141 Seminole 2012 4 "s * y 'S CITY OF ATLANTIC BEACH "--' %` r 800 SEMINOLE ROAD O ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000070 Date 1/18/12 Property Address 141 SEMINOLE RD Application type description ROOF PERMIT Property Zoning TO BE UPDATED Application valuation . . . 2400 Application desc NEW METAL ROOF OVER EXISTING Owner Contractor AMOS, MICHAEL OWNER 141 SEMINOLE ROAD ATLANTIC BEACH FL 32233 Permit ROOF PERMIT Additional desc . METAL ROOF OVER Permit Fee . . . 65.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 2400 Expiration Date . 7/16/12 Other Fees STATE DCA SURCHARGE 2.00 STATE DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 65.00 65.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 69.00 69.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247 -5826 Fax (904) 247 -5845 Job Address: I y / 3c m t 4 j� �,Q q Permit Number: Legal Description Parcel # Z 4v ° Floor Area of Sq.Ft. Sq.Ft Valuation of Work $ Proposed Work heated /cooled non- heated /cooled /mod O Class of Work (circle one): New Addition Alteration Repair Move Demolition pool /spa window /door Use of existing /proposed structure(s) (circle one): Commercial 1 -sidential If an existing structure, is a fire sprinkler system installed? (Circle one): es l N /A Florida Product Approval # q 5 For multiple products use product approval form Describe in detail the type of work to be performed: , s �-e� rn e-�- < _ r e X t 5 Co o Property Owner Information: Name: L � c�.¢_ ( vvN v 5 Address: t K l 5 m% h o (-e City 'n ■ • -c.-c l.._ State'= l-Zip 7Z : 3 Phone ?13 7 1 70 6 E -Mail or Fax # (Optional) Contractor Information: Company Name: Qualifying Agent: Address: City State Zip Office Phone Job Site/ Contact Number Fax # State Certification/Registration # Architect Name & Phone # Engineer's Name & Phone # Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six (6) months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate permits must be secured for ElectricallYork, Plumbing, Signs, Wells, Pools, F urnaces, Bo Heaters, Tanks and Air Conditioners, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that / have read and examined this a placation and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal, state, or • • l law regulating construction or the performance of construction. Signature of Owner �'` g - -- - � Signature of Contractor Print Name (A ( rm a Print Name 1 • _ Swor , .�'. nd subscribed l ore me Sworn to and subscribed before me Day of < G ?� 20 .x-• this Day of - , 20 . WH ,. Notary Pub. : ?'P. Notary Public "notary mpyub21 U 15 writers '*;;;;.,...0 '` BondedThruNo Revis d 01.26.10 "` CITY OF ATLANTIC BEACH ®WNER / BUILDER AFFIDAVIT I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER / BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU, AS THE OWNER OF YOUR PROPERTY, TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE — OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF $25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKERS COMPENSATION INSURANCE BE PURCHASED. III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND /OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455 - 228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE BUILDING DEPARTMENT (247 -5826) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER- BUILDER PERMIT. 1 3 `7 7 y i 7 Ci r� ADDRESB r PHONE NUMBER INV L a A 0 5 PRINT NAME SIGNA'':-E !/ DATE Before me this / day of , 20' in the county of Duval, State of Florida, has pepsgnally appeared herin by himself / herself and affirms that all statements and declaratio s.are true and accurate. Notary Public at Large, State of , County of DEBORAH AMANDA i ,+1 t Y ,, 0 Personally Known . ` :*: MY ISSION # EE 05 s7 j , / a Producedldentificat l G y "r (� ... 8onda Ma 21 2015 n - " ld - 1 oft t fly Public Uwe e Notary Signature: F: BLDG / Owner - Builder Affadavit; REVISED: 4/16/2009 Discount Direct Metal Roofing Plus Rib Roofing Panels 36" Coverage T 3/4" Installation Instructions Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong, resilient, economical, have an eye- catching solution to the increasing interest and requests for metal roofing opportunities of residential homes, commercial applications, agricultural and utility buildings in Florida. Plus Rib metal panels provide a 36 -inch coverage with 3/4 -inch ribs on nine -inch centers. and utilize an anti- siphoning channel to provide protection from severe weather conditions. Both panels and trim are fabricated using state -of -the -art computerized equipment at our manufacturing facility Jacksonville, Florida, to assure uniformity and consistency in manufacturing the product. Panels are roll- formed to the lengths specified by customers in either galvanized, Galvalume® or multiple colors of painted 26 gauge and 29 gauge high- tensile metal, ready for either customer pickup or on -site delivery. Discount Direct Metal Roofing also stocks a complete line of fasteners, sealants, and other accessories to every need of either the do- it- yourself homeowner or roofing contractor. Both in -stock and custom -made flashings and trims are available in all colors as well. Two gauges of material are available -26 -gauge and 29 -gauge metal panels. Your Discount Direct Metal Roofing Representative is waiting to assist you in making the best choice for your particular roofing needs. Discount Direct Metal Roofing Plus Rib metal panel is manufactured in a bare, Galvalume® finish in compliance with ASTM A -653 Structural Steel Grade 80. The AZ- 55 Galvalume® finish is not only durable and cost effective, but provides the reflectivity which is especially valuable with Southern weather extremes. The paint system applicable to our product provides exterior protection plus superior resistance to corrosion and Ultraviolet radiation. All of Discount Direct Metal Roofing Plus Rib finishes are of the highest quality in the industry. Eave Drip & Fascia or equivalent Typical Eave Detail For custom eave drip, specify the amount of the eave that will be covered (dimension "a "), and, for steeper roofs, specify pitch. If fascia is desired, specify the dimension you order will be concealed by the eave drip. Eave drip and fascia provide a complete appearance along the drip eave of the house, as well as providing protection for the materials they cover. The eave drip should completely cover the top edge of the fascia. Inside closures, provide for sealing off the open ribs of the panels, as an alternative option. Typical Valley Detail w �* x Preformed Valley Pre- formed valleys use a diverter to prevent water from rushing under panels on the opposite side therefore channeling water off the roof. Expanding foam closures are generally used to assure a good seal. Gable Flashing Gable flashing is used to trim the edge of the roofing panel at the gable end of the roof. It should match the eave drip extends along the drip edge of the roof. If the panel is allowed to hang over the gable end, eave drip can be used as an alternative. Butyl tape between the trim and panel eliminates potential leaks. Gable Rake /Eave Fascia - Typical Gable /Eave Detail —r--• '1 , ,r ,N,' a a: "•t ?ar,. rre lLLn.a, a h s Side -wall Flashing 1 x u s te=e ::! .. ! u A Sidewall flashing is applied when the side of the roof butts up against an adjacent wall. The wall -side of the flashing can either be covered over with siding or sealed with counter- flashing. Butyl tape should be applied where the "foot" of the flashing attaches to the roof, and, if used, along the top edge of the counter- flashing. 0 0-, .. `« a ' fit . , Nit F ____ { l caulk / counter- flashing it' Illy, Like the ridge cap, the ENDWALL FLASHING diagramed above can be sealed using outside closures. End -wall flashing is applied where the upward slope of a roof meets a wall. The wall side of the flashing can be covered with siding or counter- flashing, and outside closures are used to seal between the flashing and the panel. Roof slope should be specified when a roof slope exceeds 5/12 pitch. Transition Flashing - -- prevents leakage at the point where two different roof pitches meet. It is sealed on the lower side with outside closures, and can be sealed underneath the upper panels with inside closures. . flnTl p " ,v For custom transition flashing specify the pitches of the two roof slopes and, if required, specify dimensions "a" and b" The transition flashing provides a continuous drainage where two slopes meet. , gam • Rilaptt cap with outside closures in place ryr ° " ':' The Rid Cap is used to seal the point at which two upward slopes meet. This can be both along the ridge of the roof as well as a covering for a hip. Either wood -grip or self - drilling lap TEK screws are applied through the ribs of the metal roofing panels. Debris, insects, prevailing rain can find easy access under the ridge cap, so closures are often used to either totally or partially seal the opening. Closures under ridge caps are available in 3 types: solid, vented, and hip valley type. Standard 12 -inch Ridge Caps or equivalent ....are economical and applicable a variety of your roofing needs. �v. t '4 ; Pipe Boots provide a water tight seal around roof vents and come in a variety of sizes. Boots seal with caulk or butyl tape and conform to the shape of the metal panel ribs. Roof Pitch Discount Direct Metal Roofing panels require a specified degree of pitch to ensure proper water drainage. The minimum roof slope recommended for all panels is 3 inches of rise per foot. If the slope of the roof is below a 2/12 pitch, contact our representative before using metal roofing less than a 2/12 pitch. Florida Building Code requires a minimum of a 2/12 pitch. Roof Application • Panel installation should begin at the gable end of the roof opposite the prevailing rain - bearing wind (this will provide added assurance against wind - driven rain being forced under the laps). Measure one panel width in from the roof edge. At this point, chalk a line form ridge to eave. Place a leading edge of the first panel along this line. It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof. Make sure that the metal panels are correctly side- lapped. In applications where end - lapping is required, the upper panel on the slope should lap over the panel that is lower on the slope. Lower roof pitch requires a greater amount of panel overlap. All end -lap applications require two horizontal rows (across the panel) of butyl sealant tape and proper fastening to ensure a maximum water seal application. Providing an overhang of 2 to 3 inches is recommended to provide a drip edge, although . only a 1 -inch overhang is required where gutters are used. The open metal panel ribs at the eave can be sealed with inside closures. For maximum weather- tightness, a row of butyl tape can be applied above and beneath inside closures. Trimming and Cutting Steel Panels The best tool for cutting steel panels across the profile is either a portable or hand shear or a nibbler. Any particles left on the roof caused by the application of screws must be removed. Care should be taken to remove all loose particles from roof surfaces after application. For safety and to prevent particles from. Nibblers, panels should be cut on the ground. To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge, score deeply down the length of the panel with a sharp - pointed utility knife. Folding the panel along the score mark, and bending back again if necessary, should produce a clean break in the panel. Ordering Roof Panels and Screws Care should be taken when ordering metal panels that correct length measurements are stated to avoid having to take corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when a vented ridge is desired and should extend 2 to 3 inches past eave to allow a sufficient drip edge (except concerning gutters). The Discount Direct Metal Roofing sales personnel are ready to assist customers with information specific to their particular metal roofing needs. Specially- washered screws applied through the flat of the metal is the recommended method used to attach metal roofing panels. 1 -inch screws can be used if penetration of only' inch is either necessary or desired; otherwise, #9 x 1 -'/ inch screws are recommended for metal to wood application. 2- '/z inch screws are also available, and are often applied by installers who hold to through- the -rib fastening, and for ridge -cap application. Ordering and Applying Trim Common flashing for metal roofing is the ridge cap, which is applied at the peak of a roof where two opposing roof slopes join. Other flashings include transition flashing, end wall, sidewall flashings and valleys. Eave flashings include gable flashing and eave drip, which are commonly applied above fascia trim. For a roof pitch exceeding 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be specified upon ordering ridge caps, endwalls and eave drip. Verify local code requirements. Both slopes should be specified when ordering transition flashing if a steeper roof slope meets a lesser slope, At the gable edge, the use of gable trim adds to the appearance of the structure and protects the fly - rafter, and a sidewall flashing is used where the side of a panel butts up against an adjacent wall. In both instances, the installer /contractor should be careful to seal between the gable rake or sidewall and panel with butyl sealant tape, and to fasten the rake every 6 "to 12" up the slope of the roof with the required screws. If eave drip is used on the gable, the number of 90- degree eave drip should be specified separately from that used on the drip edge when ordering. To prevent penetration of water, insects, and debris at the ridge, outside closures may be inserted between the ridge cap and the top end of the panel and inside closures are used at the eaves. Screws are applied through the ridge cap, closure, and rib in at least every other rib of the panels. At least a #8 x 1" and up to a 2 %2" screw should be used for attaching panels. Self- drilling lap screws should be used to attach ridge caps. Keep Metal Roofing Product Materials Dry Paint and finishes of Discount Direct Metal Roofing panels and trim are designed to endure severe rain and wet weather conditions. CAUTION: Neither paint. galvanized. nor Galvalume finishes, are designed to be in continuous contact with water or condensation for long periods of time. Damage will result if uninstalled panels or trim are allowed to remain wet in storage. Be sure to store material that will not be installed immediately in a dry location. Wet material should be air -dried and re- stacked if installation immediate. NOTE: Plastic should not be used to cover metal panels. How to Figure Screws: On low- pitched roofs, butyl tape or caulk should be applied at the panel lap to keep water from overflowing the lap. For 2 -foot spacing between rows of screws, multiply the total linear feet of metal times 2.7. Example: If your order is 1500 feet of Plus Rib roofing. 1500 x 2.7 = 4050 screws would be applicable for fastening. Contact your Discount Direct Metal Roofing representative for a free estimate. Metal roofing application can be aided by pre - drilling panels, allowing screws to go quickly and accurately into the desired spacing. Pre - drilling will work provided that pilot holes are placed accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured. To apply metal roofing over existing shingles, we recommend first overlaying the shingles with properly attached 1x4 or greater, (2x4) or metal hat channel purlins. If pressure treated purlins are used, 30 lb. felt paper should be applied over them in strips to prevent chemical interaction with the roofing panels. High Velocity Wind Zones For solid decking, at least 1/2 -inch structural plywood or OSB (5/8" for any High velocity wind zone of 120 and above) supported on rafters at a maximum of 24" on center. Battens: Plus Rib Metal Roofing can be separated from the moisture barrier by minimum, nominal 1"x3 yellow pine battens spaced on maximum 24" centers or according to ASCE 7 -98 calculations where applicable. CAUTION: Direct contact between pressure treated lumber, green, damp, and metal roofing must be avoided in order to prevent potential corrosion and moisture build -up. The battens must be fastened to the roof deck with minimum #6 screws at 12" on- center or two minimum 8d common or pneumatic nails spaced 8" on- center or one every 4" on- center (or by applicable calculations according to ASCE 7 -98.) Battens must be installed to support the entire width and Length of ridge, eave, hip, valley, and gable end trims. Battens are optional if re- roofing over shingles. NOTE: Re- roofing over shingles without a batten is allowed providing the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity. if 7:7 { I l k ' Lave .�.rtxrr Patleiri G�t�i1 � \ tt �` M g 4 .. �� ,» : �, _. w,���k�r�:, »,. ,.. •�.,. ,, rna.«na ., ^a�».p..'+�s,�, «,�,:�� rte* ,»�s+��K»»�*n:; Purlin spacing can be up to 30 inches for 29 -gauge (2 feet is most common) and up to 4 1/2 feet for 26 -gauge roofing. Screws should be placed on both sides of the ribs on the eave. Screw Spacing (Purlin) 12 inch 18 inch 24 inch 30 inch .. 50 270 180 135 108 a la 100 540 360 270 216 0 16 200 1080 720 540 432 E 300 1620 1080 810 648 c •— 400 2160 1440 1080 864 ta l 500 2700 1800 1350 1080 a 600 3240 2160 1620 1296 .48 700 3780 2520 1890 1512 800 4320 2880 2160 1728 900 4860 3240 2430 1944 i 1000 5400 3600 2700 2160 •-= 1100 5940 3960 2970 2376 1200 6480 4320 3240 2592 Policies Indemnity: All prices and designs are subject to change without notice. Disclaimer: Despite the fact that we have made every attempt at accuracy in this manual, we are not responsible for typographic, printing, or technical errors. Manufacturers Recommended Alternate Fastening Schedule Alternate Fastening Schedule (On Center Spacing or Fastener Row) F IZ 4D I t) 1.5 Wind Speed Zone Type Placement To Fastener 90 100 110 CO • Ci) Sizo 5 .51 On Center Trim On Center Trim On Center Trim Spacing Areas Spacing Areas Spacing Areas s ci) - ------ ---- - ct ok Zone Nall Wood 10d x 1-3/4" 24" 12" 24" 12" 24" 12" Wood Fast Screw Wood 49 x 1-1/2" 24" 12" 24" 12" 24" 12" C4 _ Wood Fast Stitch Wood 412 x 314" 12" 12" 12" 12" 12" 12" CD ;et CA Metal Fast Stitch 18 Ga Steel and Higher 412 x 1" 36" 36" 36" 36"36" 36" CU Cid Metal Fast Stitch 20 Ga Stool and Lower 414 x 7/8" 12" 12" 12" 12" 12" 12" = 44 4) CJ 44 Nail Wood 10d x 1-3/4" 12" 6" 10" 5" 8" 4" at Cti 1 4.01 ll: Wood Fast Screw Wood 49 x 1-1/2" 24" 12" 24" 12" 24" 12" = ale 1:1 Clo Zone Wood Fast Stitch Wood 412 x 314" 12" 12" 12" 12" 12" 12" CI 4..4 2 & 3 't Metal Fast Stitch 18 Ga Steel and Higher 412 x 1" 36" 36" 36" 36" 36" 36" Metal Fast Stitch I 20 Ga Stool and Lower 414 x 7/8" 12" 12" 12" 12" 12" 12" ------