Plans 1825 Ocean Grove Dr 2012 addition LUCAS&SCOTTENGINEERINGINc 12627 San Jose Boulevard, Suite 603 • Jacksonville, Florida 32223 Douglas V. Lucas, P.E. Licensed in Florida Office (904) 260 -2690 Fax (904) 260 -2671 doug @Lucas- Scott.com February 7, 2012 City of Atlantic Beach Building Department 800 Seminole Road Atlantic Beach, Florida 32233 Re: McClai 1825 Ocean Grove Drive, Atlantic Beach, Florida, Engineering Job No. 111221, Design Modification 1— Balcony Cantilever Joists To Whom It May Concern: 1. Balcony joists shall be cantilevered a maximum of 24 ". 2. Balcony joists shall be 2x12 SYP #2 PT @ 24" o /c. 3. Girder joists attached w/ (2) 2x12 SYP #2 filler & nailed w/ (2) rows 16d nails @ 12" o /c. 4. Cantilever joists attached to girder w/ LU212 hangers. 5. Cantilever ends supported on 2x6 @ 16" o/c kneewall approx 6" high. Joists may be notched 4" max for stepdown. 6. 2x12 blocking between cantilever joists. The engineering changes to the subject project are structurally satisfactory. If you require any additional information, please do not hesitate to contact me. Sincere Douglas V. Lucas, P.E. Structural Engineer • ddo ®�dtI Ut®ir',�1, o ® o o Q , � �L I C E�• �/ �O® *, • . • 94 • 0 1. :O ...;= .P� r. REVIEWED FOR CODE COMPLIANCE . CITY OF ATLANTIC BEACH ..�,.. ..,. w., /1 IL E \ SEE PERMITS FOR ADDITIONAL_ "'^ s+*tw; ; ,. REQUIREME D CONDITIONS. REVIEWED BY DATE: 0 2 - FILE Copyi "r _ MP'•MM'+illrt.::.:'K u.. : 1 Mi. 9 W..MKMNMRMIyp r