Loading...
Plans 1993 Colina Ct 2012 new porch at front entry r an LEE J. ENGINEERING, INC. 10381 Cypress Lakes Drive Jacksonville, FL 32256 Phone 904 - 519 -1934 Fax 904 - 519 -1004 CeII 904 - 234 -3518 April 3, 2012 Building Inspector Building and Zoning Department City of Atlantic Beach, Florida Ref: 1993 Colina Court, Atlantic Beach, Florida 32233 Permit No. 12 -0087 Dear Inspector: I have performed site inspection and instructed the followings: 1. Collar ties at front porch can be omitted by providing front tie member with 5 -16d nails to connect roof beams. 2. Existing header and jack studs at old entrance door area can be removed. But existing floor joists 2x10 @ 16" on center do require hanger of Simpson LUS210 to the existing 2 -2x10 beam and the saw cut at the bottom of floor joist end need to provide MSTAl2 for reinforcing joist. This procedures shall be done before removing existing door header and studs. If you have any questions, please contact me. Sincerely, LEE J. ENGINEERING, INC. �� " `1M':.,•. :.+nr ,,.,emnM n. . J: e -e P. E. ( #31276) FIL E COp y 'residen REVIEWED FOR CODE COMPLIANCE I CITY OF ATLANTIC SEE PERMITS F ADDITIONAL REQUIREMENTS AND CONDITIONS. REVIEWED BY: ..� DATE: