Loading...
Permits 90 Ocean Breeze Dr (vault) w .r ADDRESS 90 cC_a/�� BUILDING PERMIT NUMBER 15'g0 7 INSPECTIONS : FOOTING UNDER SLAB PLUMBING oSt�-l�cL 10-21- `�7 5 SLAB FRAMING COVER-U? INSULATIOPI FINAL BUILDING CERTIFICATE OF OC CU PAN""`_' ELECTRICAL PERMIT # /S`fCo INSPECTI 311T-c' ROUGH FINAL MECHANICAL PERMIT t# PLUMBINi PERMIT # NOTES : ADDRESS- 9i!!� &�-a-4t'� BUILDING PERMIT NUMBER INSPECTIONS : FOOTING UNDER SLAB PLUMBING SLAB r7 - FRAMING _FRAMING COVER-UP INSULATION /0 FINAL BUILDING CERTIFICATE OF OCCUPANCY ELECTRICAL PERMIT # INSPECTIONS ROUGH -- F I NAL MECHANICAL PERMIT # � PLUMBING PERMIT NOTES : CITY OF ATLANTIC BEACH i 800 SEMINOLE ROAD J ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026100 Date 7/01/03 Property Address . . . . . . 90 OCEAN BREEZE DR Tenant nbr, name . . . . . . POOL Application description . . . POOL Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 31538 Owner Contractor ----- ------ - ----------- - ------------ ------------ WALSHAW, LARRY E CLIFT & CO POOLS & SPAS 9340 ARLINGTON EXPRESSWAY ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 855-0019 ------- --------------------------------------------------------------------- Permit ELECTRICAL PERMIT Additional desc . . Sub Contractor . . SIKES ELECTRICAL CONTRACTOR Permit Fee . . . . 75 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 75 . 00 75 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL P, 6 100 1 e sf CITY OF ATLANTIC BEACH, FLORIDA " ELECTRICAL PERMIT APPLICATION will), TO THE CHIEF ELECTRICAL INSPECTOR: DATE: '7 - 20 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL CONTRACTOR: c l �Z r MASTER ELECTRICIANS SIGNATURE: OWNER OF PROPERTY: ( '"45 1 4u— 1 JOB ADDRESS: 4,cl Q r)c C/4't') �' �` le RES APT.( ) COMM.( ) PUBLIC( ) INDUS.( ) NEW( ) OLM-A REW.( ) ADDITION( ) TRAILER( ) TEMP.( ) SIGNS( ) SQ.FT/s'L 11 SERVICE: NEW( INCREASE ) REPAIR( c-(/�t�^ r,a� CONDUCTOR SIZE AMPS: COPPER( } ALUM.( FEES SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST. SERV. SIZE © AMPS PH W VOLT RACEWAY jr FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30AMPS 31.100 AMPS SWITCHES INCANDESCENT FLOURESCENT&M.V. FIXED 0.100 AMPS, OVER APPLIANCES BELL TRANSF. AIR H.P. RATING H.P. RATING CELL. KW-HEAT CONDITIONING COMP.MOTOR OTHER MOTORS AMPS HEAT 0-1 OVER MOTORS H.P. VOLTAGE PHS NO. I H.P. VOLTAGE PHS MISCELLANEOUS UNDER 600V OVER 600V TRANSFORMERS: NO. IKVA NO. IKVA NO.NEON TRANSF. NO VA I MA MOTOR SIZE I SWITCH FLASHERS EACH SIGN 800 Seminole Road• Atlantic Beach, Florida 32233-5445 Phone: (904)247-5800• Fax: (904)247-5845• http://www.ei.atlantic-beach.fl.us RPviged nvi7ma ix CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Build ing-dWt(q-),cogb.us Application Number . . . . . 07-00000498 Date 4/13/07 Property Address . . . . . . 90 OCEAN BREEZE DR Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------------ Application desc KITCHEN REMODEL ------------------------------------------------------------------------ - Owner Contractor - ------------------------ ----------------------- WALSHAW, LARRY E BILL THOMPSON ELECTRIC CO, INC 49 WEST 7TH ST ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 249-5601 ------------------------------------------------------------------------ Permit . . . . . . ELECTRICAL PERMIT Additional desc . Permit Fee . . 105 .00 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/10/07 ---------------------------------------------------------------- - Fee summary Charged Paid Credited Due ----------------- ---------- Permit Fee Total 105 . 00 105 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 105 . 00 105 .00 .00 .00 PERMTT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION Date: / C� Property Address: �� aGeWl Owner: Telephone #: Contractor: ?Aon MISS Telephone #: Contractor Address: Adan ie Bea*F'32233 Fax#: Z—T®-- Contractor Signature: In consideration of permit given for doing the work as described i e above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: ❑ Trailer Service: If other construction is ❑ New 6'--Residence ❑ Temp. ❑ New, being done on this building Or site,list the building ❑ Old ❑ Commercial ❑ Signs ❑ Increase Permit number: Lr—Re-wire ❑ Addition Sq. Ft. ❑ Repair Conductor Size: AMPS: COPPER ALUMINUM El Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service 2 '2.t RACE Size AMPS PH W / VOL `20 WAY i/ Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED Z OPEN Receptacles CONCEALED OPEN Switches y I Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER I H.P. PHS LTNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon_Transf. Ea._Sign Miscellaneous r 800 Seminole Road - Atlantic Beach, Florida 32233-5445 Phone: (904)247-5800- Fax: (904)247-5845- _ht_tp://www.ci.atlantic-beach.fl.us Revised 1/04 N UP Beach Pefmitlnfot� n To: JEA Electric Order Fulfillment, (Fax No.: 665-7372) Attention: Carol Schweizer/Lorie Craven,21 West Church St T-4 (665-6521) Subject: City of Atlantic Beach Permit# Date: Service Address: kuxn ?y eey, Ile Owner: 5� �� Owner Phone: Electrician: i j1 1IZU��2a '1Cfi?� CSD . _ifs Electrician Phone: Type of Work: New Service [�] M-Home Subfeed [] Increase Service Heat & AC [__] Repair Service [�] Other Rewire [ ] Other Description: Temp Pole Service Type: [T_],Overhead (Repair/Replace) [___Underground(New Services) Building Use: [„]Residential LJChurch ]Environmental "M-Home "Commercial "Other Other Use Description: Service Size: New Service: Amps: Volts: Phase: Existing Service:Amps: 2U Volts: 2D Phase: E-mail:cravli(a jea.com or schwclnc jeea•cotn or resomagica.com CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026575 Date 8/14/03 Property Address . . . . . . 90 OCEAN BREEZE DR Tenant nbr, name . . . . . . ALUMINUM SCREEN/POOL ENCL Application description . . . SCREENED ENCLOSURE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 9500 Owner Contractor ------------------------ ------------------------ WALSHAW, LARRY E TROPICAL ENCLOSURES INC. 926 N. 9TH AVENUE ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-2298 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 80 . 00 Plan Check Fee 40 . 00 Issue Date . . . . Valuation . . . . 9500 ----------- -- ---- -- ---------------- ----------------------------------------- Special Notes and Comments ENCLOSURE MUST BE MINIMUM 5 FEET FROM ALL PROPERTY LINES . Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 80 . 00 80 . 00 . 00 . 00 Plan Check Total 40 . 00 40 . 00 . 00 . 00 Grand Total 120 . 00 120 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH ccVHiggins S BUILDING / ZONING DEPARTMENT '' 800 Seminole Road r Atlantic Beach,Florida 32233 -• _. (904)247-5800 (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # C,,3 - z[c , 7_S Property Address: CIO Ce cc_c'-) Applicant: —1 ID Com.. ry 0 1 LtL' Project: A lu m i n w vv"1 t--5p re li 4 POC 1 ErLC /C-& This permit application has been: El Approved Reviewed and the following items need attention: Job Please re-submit your application when these items have been completed. Reviewed By:�( - Date: -7-.2 o Z tt) CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION (ALTERATIONS/ADDITIONS) C ' Date: Job Address: C10 C&ITN�-- Owner of Property: 1-0 Q.- z, rn!LS R!t Von L ;w A,-V Address:`]() po—_ Telephone: FN9 " 73,3/ Legal Description: Block Number: Lot Number: Zoning District:0-eZA� 9- �- Contractor: e-C State License Number: CAC: fS ey Contractor's Address: ZZ_-121✓U�2� r'�l� --�%� Imo£='E'ftd►� ACWL Telephone: SLI i Fax: Describe proposed use and work to be done: �rtn r t►�.�v N tr ��''u=u5' Present use of land or building(s): Valuation of proposed construction: 9_ 5©� What are the dimensions of the added space: feet xfeet j Will the added area be heated and cooled? q0 New electrical or increase in service? N b New plumbing fixtures? C7 New fireplace? b New heating/air conditioning? N rS Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will t is project involve changes in elevation,site grade or any use of fill material or the removal of any trees? NO. Applicant certifies that no change in site grade or rill material will be used on this project. ❑ YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. 12/r�O. Applicant certifies that no trees will be removed for this project. ❑ YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor,and foto(4)complete sets of construction plans to the Building Department,which is located at the Atlantic Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 •Fax: (904)247-5845 •http://www.ci.atiantic-beach.fl.us Page 1 Revised 1/14/03 In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations: include driveways, sidewalks, patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information as may be appropriate for individual applications. I hereby certify that all information provided}with this application is correct.. Signature of owner: J r /' a Y ) "' Date: I hereby certify that I hav d and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. ` Signature of Contract . Date: Address and contact information of person to receive all correspondence regarding this application (please print). Name: Mailing Address: / Telephone: Fax: E-Mail: AS TO OWNER: x Sworn to and subscribed before me this day of _�V , 20eQ . State of Florida,County of Duval •N" •N• ROY•ROCKHOLD•••••�= Notary's Signature. Commission#DD0121151 Expires 5/27/2006 Personally known at Bonded through Produced identification tepp.{32-42Florida Notary Asan.,Inc. ,ok 54) _ Florida ••••••••••••►•••••••••••••••• Type of identification produced la ., AS TO CONTRACTOR: Sworn to and subscribed before me this day of , 2003. State of Florida,County of Duval ROY ROCKHOL �op�mammmnsmmaaommmeumwmmmammm�mN D Notary's Signature: Commission#DD0121151 Expires 5/27/2006 g Bonded Personally known tpyy�, MFlorld' Asw.ima Produced identification Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 •Fax: (904)247-5845 - http://www.ci.atiantic-beach.fl.us Page 2 Revised 1/14/03 Cc: CITY OF ATLANTIC BEACH D_flm�w �i3 f BUILDING / ZONING DEPARTMENT `ss1 J 800 Seminole Road J � Atlantic Beach,Florida 32233 (904)247-5800 (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # C/3- - 2&,,5; 7,S Property Address: qD Occar, i3ree7' Applicant: __J_M 1c C41 art(' / c 1 ✓c' C Project: in tcvvt. "CrCCit >Oct ror,C �� c This pe it application has been: Approved ❑ Reviewed and the following items need attention: Please re-subt our applic -on when these items have been completed. Reviewed B � Date: �- 2 9��3 r 3D VIEW ,� r Cage Master 2000 CopyR19h11991.1%9 Wllaon Software Corp.Englewood,Florida 07-20-2003 Customer : WALSHAW v ,wL 0:11 v�► �U 1D D �}L a ,*ti Citi �y cd. _ �7i MAP SHOWINC BOUNDARY SURVEY OF LOT 11, REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A,OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA, CERTIFIED TO: LARRY E. wALSNAW AND MICHELE 0. WALSHAW, 1995 COMWNWEALTH LAND TITLE INSURANCE CO. SUNHANK / NORTH FLORIDA, A NATIONAL ASSOCIATION, Qullding ani Zamng LOT I OCEAN '13REEZEDRIVE 1,"X I +N89'-43'-35"E 60.00' (k'2 Ls Io s6 cAF PRIVATE ROAD ) 30'EASEMENT POR WORESS 6 EGRESS DRAWAGE AND UTILITIES i{ALT PAVING 16"CONC n _ CUP6 AND 6UT SER (� 40,00' -- 7 I ,` q Q O 12.8 6R.L. •N _ t4,0' 9� NO.43 ' 1 I` C) iV 5 Q M w C) LOT 10 4.6' o.r 14 o I 4.51 �y ® .2'I' $ i 0.4 k � d 0 2-STORY sTucco 'n I WS)DEWE NO,90 lU 6'wt N W 'n 1e T W N PSE ' 0 lD r 4 z 0 0 3.4' W z ,SSI � 13.r � A•�d �i o ,0,d s FD.TAcx 6 ,00 IN cco4c , 12+64 y _ — — - or 5691-43'-35"W — srvx01004NarE hpE TRM Womw ARF FROM REVISED 12.4-94 TO SHOW Fk1AL IW'ROAMEXTS 6-3'94 SURYV REV16ED 7-26-94 TO SHOW FOUNDAT)Ok /,/ - - - .+�A , ♦►111 C1 g7U* yo RSINC. now mrnn)ur-c cncrn nu PLAT OF RECORC Book 11244 page 614 5 MIN. RETURN PHONE NOTICE OF COMMENCEMENT State of Tax Folio No. County of To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: LO7 t-) c:-LAtii PW U t Address property bein improved: w.� r �~ NGeneral description of improvements: rr Owner: J . i-�- ft-;`- Address: " !-" A- Owner's interest in site of the improvement: Fee Simple Titleholder(if other than owner): N f� Name: F..+ (A Address: N Contractor: h6kkh - tr't �-►� z T' Address: Phone No: '-Z-1,41 —'Z"L`1 Fax No: Surety (if auy): = 7f Address: -Iq -7:;t;, Amount of Bond $ "' o Phone No: Fax No: Name andap dress of any person making a loan for the construction of the improvements. Name: TM Address: N Phone No: Fax No: Name of person within the State of Florida,other than himself, designated by owner upon whom notices or other documents may be served: Name: 1-f Address: N Phone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's tion). Name: Irl �,j \A./ � �V,,��.s r'ro\� I i, Address: Phone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed; Date: Before me this day of - in the County Dorii:2i41i�3�441269 al, St Florida,has personally appared Book. 614 Filed I Recorded Notary FUlic at Large, State of Flq;�¢ ,�g .A�LZuv.1J.•,•••«•••.� 07/225/2043 03:36:32 Ph My commission expires: r aY►ate OY ROtnDo 21151 D JIM FULLER Personally Known: 7 ooe • or CLERK CIRCUIT CUT cum Produced Identification: mcough RECORDING $ 5.00teowx�.asst) Florida ary ASM,ine TRUSTFUND $ 1.00 N•.N...N...NN.............NNNNNN..N COPY FEE $ 1.00 �`\\ CERTIFY �% I _ PREPARED 7/03/03, 14:02:21 INSPECTION TICKET PAGE 9 CITY OF ATLANTIC BEACH INSPECTOR: LARRY J HIGGINS DATE 7/07/03 ------------------------------------------- ---------------------------------------------------- ADDRESS . : 90 OCEAN BREEZE DR SUBDIV: TENANT, NBR: POOL CONTRACTOR CLIFT & CO POOLS & SPAS PHONE (904) 855-0019 OWNER WALSHAW, LARRY E PHONE PARCEL 168908-8255- - APPL NUMBER: 03-00026100 POOL ------------------------------------------------------------------------------------------------ PERNIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ 18 01 6/16/03 LJH STEEL FRAME INSPECTION TIME: 08:00 6/16/03 AP REBAR 324-2937 16 01 7/07/03 LJH TIME: 08:00 Qtkkw*tw(' P t �_ -Ltf__ 855-0019 ------------------------------------------------------------------------------------------------ PERMIT: ALEC 00 ELECTRICAL PERMIT SUB: SIKES ELECTRICAL CONTRACTOR (904)237-2890 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETEVRESULT SULTS/COMMENTS ------------------ -------------------------------------------------------------- 23 01 7/07/03 TIME: 08:00 ��. (ngta.U'� -------------------------------------- COMMENTS AND NOTES -------------------------------------- nCITY_OF /r TY��G�fG 1SPGCi�-�hDZKi4 Office of Building Official REQUEST FOR INSPECTIO L� j Date_ �,�- � Permit No. j Time A.M. Received P.M. Job Address Y f7 Owner's Name �X l Contractor BUILDING CONCRETE ELECTRICAL PLUMBING �EC.HANICAL Framing O Footing ❑ Rough Wiring ❑ Rough 71=1 Re Roofing ❑ Slab L Temp Pole _ Top Out ❑ Heating Insulation 11 Lintel ❑ Final ❑ Sewer O Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. Mon. Tues. Wed. Thurs. Friday P.M. py J A.M. Inspection Made J P.M. InsP ector ti--.� . Final Inspection ertificate of Occupancy ❑ Date //C��ITY�� OF .8"04 //�__ ��/� fY*fIfi/LKC /3"04-I( Sd- 4� Office of Building Official REQUEST FOR INSPECTIOM Date � Permit No. �7 Time A.M. Received P.M. g � NAS prt —� Job Address n Locality OwneName rs c Contractor �Y�IyK ,✓ PC ' r BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Rough ❑ ond:& ❑ Re Rooting ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final ❑ Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION (� A.M. Mon. 'Y Tues. Wed. Thurs. Friday P.M. T Inspection Made tr 11 A.M. P.M. Inspector Final Inspection ❑ ( Certificate of Occupancy❑ Li 1CL�1 �r( ZJ�l/4WV Date CITY OF ATLANTIC BEACH EC HANICAL PERMIT -- 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 ------ -PERMIT INFORMATION---- ---------- -- ---- Permit Number: 22971 -—----- �- ___LOCATION INFORMATION - — Permit Type: MECHANICAL Address: 90 OCEAN BREEZE DRIVE ----i Class of Work: ALTERATION ATLANTIC BEACH, FLORIDA 32233 Proposed Use: Township: 0 Range: 0 Book: Square Feet: Lot(s): 11 Block: Section:0 Est. Value: Subdivision: OCEAN BREEZE Improv. Cost: __Parcel Number: Date Issued: 11/02/2001 — OWNER INFORMATION -- Total Fees: 27.00 Name: LARRT AND MICHELLE WALSHAW-= Amount Paid: Address: 2139 SEMINOLE ROAD Date Paid: 11/02/2001 271 ATLANTIC BEACH, FLORIDA 32233 1 - — ____Work Desc:—REPLACE Phone: (904)365-5820 CONDENSER ----- — -------- — _ CONTRACTOR S - ROBERTS HEATING AIR CONDIT R APPLICATION FEES ----- - j -- 27.00 m � On ' 1 -J. � JA'+`•_ : yy _• wi�e5 FINALS y,Y + ��,q;F• acr' t }v�"PSi'.c , .a `k vc t � 5 S• 'y, , " 5-- ,y, -L "c,°3 S ,V x�,c+�sv � �'3Yc}'P `"""�. �v,*�• r=-J•e 3 k'� .0i 02 a NOTICE Bxl � AIw .� 13T ,+` kJ ' � ' 1P{CTION --' E BUILDING MATERIAL '' y --- MUST BE CLEARED Iilj1C � P tiS}P�LiC SPACE,AND — --- NY '4�# CON .FAILURE TO COMP — ----- 1 PROPERTY OWNER PA IN THE ISSUED ACCORDING TO APPRO Ir FOR VIOLATION OF APPLICABLE PR H T i AND SUBJECT TO REVOCATION I� 1 _ ! ATLANTIC BEACH BUILDING DEPT. $27.1* 14 1 --- Date: 11/85/91 91 Receipt: IIM446E S �� ,._--------- 8818888 — BUILDING AND ZONING INSPECTION DIV15ION CITY OF ATLANTIC BEACH ATLANTIC UC".rLOR1dA 1AA11 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER glDENIMPORTANT—Applicant to compiete oll items in sections 1, fl, 111, and IV. TIHC.0�A'TION fShl '—To be completed by all applicants, 1 p.mil qw. fo. d.i.q Ih. -..Y ..d-l".d Ih+ .6... d.t.w..wt -.6...6r •q••• f.p•r!w ..Id+.d iw.....d.we. i1h th• .Ihch.d pt ^ ..d .p.df{<+Ilan. .hi<h ... p.rt 6....7 .+d .w .c<..d..<. �:Ih 16. Ciiy e!�ackwn.:N. wd{...... ... d••dard. N.w.. .l u.a6.wl..i .wh..t... �- c.wh..t.r rr.F.rfy o...r srq.•+r.. .l a..w.r siq.+t.r. .r •r A.th«Lad Aq..t _ A.a6il.a1 •r E.glw..r Ill. GENERAL INFCRMATION A. Typ..f h..n.q N.W. S. 13 OTNCA CONSTRUCTION 361N0 OONC ON / 1 ❑, Bweh(a TNI! BUtLOING OA SITE? ❑ s.. ❑ Lr Q N.1.-1 Cl a.tr.l ulmtr Ip TES, GIVE NulwaER OF CONSTRUCTION Q Op PEAmlT Q OM.•r - Sp.<ify IV. MIICNANiCAL!1¢UIP.4WT 1`7 11 INSTALLED NArUNE OF WORK . (rrs.+al.wnplal.IIA.f c...p.w..h..6acY.(this 6.- Mu{.w•.lw cap.dt/y• �� `_ Rsesd.nt.lwi or Cl comma rclal Q* M.st ❑ Sp.0 C3 --J C2 C-mi Q Fk l New Building / Al,C-4oll {.o: C3 C-" BWlding ❑_ / 5R.71aC.mnl of al.ling vy l.n D.cf Srt-, W.bThick � 1w- y .m of-iaualy In•tall.d) Q Rdriq.^ ❑ Ett.n.ian or sdd-an to•aisling.Ta.m . 3a.clfy ❑ G.U.q i...•rx C+p.city q•a>� ❑ Oth.e-- Q Rr. n-4-1. N...6•r .1 h..d• Q Ei+.•w Q FA•MIR ❑ E.a.l.t+• (•""'�I THIS STAG }fJR Og4C1 U2Z ONL7 - Q Q U.16.d p..••.n..... ❑ Othar-•Sp-h UST ALL ZgEnP!AENT ALL CONDTTIOMNO, AMD AEPRIGERATSON ZQUVMENT 2fta.th.rU'sita D+wrfOrlaa Xodd?fumtwr XussQa.sfsv.r LY 4151 UXA. NG FURNACES. BOILERS, PTABTL C= I'na+.b.r Qslta Da.arlafla X.4.1 Numbs lCmaulaa�ev (�'IZ71T TANY3 lbw x-7 :(oaemrt GD-aiRT T"* L quL4 ?Casa of S++{•I APP''avin .a4 Dbe.odeea Caata/n.d }(.aalaaltayr 010. Ai�7 PREPARED 6/16/03, 8:52:08 INSPECTION TICKET PAGE 13 CITY OF ATLANTIC BEACH INSPECTOR: LARRY J HIGGINS DATE 6/16/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 90 OCEAN BREEZE DR SUBDIV: TENANT, NBR: POOL CONTRACTOR CLIFT & CO POOLS & SPAS PHONE : (904) 855-0019 OWNER WALSHAW, LARRY E PHONE PARCEL 168908-8255- - APPL NUMBER: 03-00026100 POOL ------------------------------------------------------------------------------------------------ PERNIT: BLDG 00 BUILDIIIG PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ 18 01 6/16/03 LJH STE & FRAME INSPECTION TIME: 08:00 324-2931 -------------------------------------- COMMENTS AND NOTES -------------------------------------- 4 S �i 1.1i�Jr1r� CITY OF ATLANTIC BEACH z 800 SENUNOLE ROAD �- ATLANTIC BEACH, FLORIDA 32233 .3 INSPECTION PHONE LINE 247-5826 '�J13Ir Application Number . . . . . 03-00026100 Date 5/21/03 Property Address . . . . . . 90 OCEAN BREEZE DR Tenant nbr, naive . . . . . . POOL Application description . . . POOL Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 31538 Owner Contractor ------------------------ ------------------------ WALSHAW, LARRY E CLIFT & CO POOLS & SPAS 9340 ARLINGTON EXPRESSWAY ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 855-0019 ----------------- ------------------------------- ---------------------------- Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 190 . 00 Plan Check Fee 95 . 00 Issue Date . . . . Valuation . . . . 31538 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 190 . 00 190 . 00 . 00 . 00 Plan Check Total 95 . 00 95 . 00 . 00 . 00 Grand Total 285 . 00 285 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL � t j« CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE:(904)247-5800 FAX:(904)247-5805 SUNCOM: 852-5800 d http://ci.atlantic-beach.fl.us y � r PLAN REVIEW COMMENTS Permit Application # O 3- Z�► Applicant: LJET 1 1 • —pno `� J Address: C > Project: o ( C1 Your application is approved o your permit application has been reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed by Signed Date ' �_ APPROVED Contractor Notified Date CITY OF ATLgryTIC BEACH BUILDING OFFICE MAY 2 01003 By: Mar 24 03 02: 25p Building Department 247-5845 p. 1 'r J� ' t C'0 CITY 'f CITY OF ATLANTIC BEACH POOL PERMIT APPLICATION ,rr Date: Jab Address: 90 Oe E'er 6 ree'Z.e 2�,/• A j"/Q.-t a c i, m j 32233 Owner oi'Property: LG'•� e0e/.S-` a.� Tclephone(gc'yJ '(/7 00'-.)-/ Pool Contractor: E'� e �/ � ^ c J f o,r /S —ar, r---S Contractor's Address: �j yc7 )7/1 •7��D r a L 7—�Cp c/ �}��Cr �z -3 Z'ZZS" Telephone: `�'- � a Ste- (�(3 g Fax: g� State License Nulnhc:r: �1F'�..' ����(p .S Valuation of Proposed construction: � ��,�j'I 's: V V v S1TF, PLAN front APPROVED CITY Of ATLANTIC BEACH BUILDING OFFICE MAY 2 u 2003 ay: rear Signature of Owner: �,•{, ,. . _... Signature of Contractor: 804 Seminole Road•Atlantic Beach.Florida 32233-5445 Phone:(9114)247-5800. Fax: (904)247-5845. http://WWW.Ci.atlantic-beach.tt.ur Revised 1/14/03 nor cY uo ue: otp nuiiains uepartment �4r-tra4b p. 4 OWNER'S AUTHORIZATION FOR AGENT C144 4 + C / Oo is is hereby authorized to act on behalf of f, 04SJ)aLD the owncr(s) of those lands described within the attached application, and as described in the attached deed or other such proof of ownership as may be required, in applying to the City of Atlantic Beach, Florida, for an application related to a Development Permit or other action pursuant to a: ❑ Zoning Variance ❑ Appeal ❑ Use-by-Exceptionv❑� Fence or Pool Permit ❑ 1 Retonin El Sign Pcrmit ❑ 1 P1ac or 1 t ❑] Other l tea.. BY Sioatulf9wner Print Nr e Signature of Owner Print N:une Telephone Number Statc of Florida County of Duval Signet!and sworn before\me on this. _day of.200-?;' l By_ _ Q _ 1[� Q k� .� Identification verified: r Oath sworn: Ycs No o naturcHEATHER D.CLIFr MY COMMISSION#CC 310738 rch 14,2044 ^- „qd��•.• un eof Yc MAP SHQW ING-BOUNDARY SURVEY OF LOT 11, REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, r OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. � � CERTIFIED TO: I LARRY E V A AH W AND MICHELE D. WALSHAW, :^,t.1 2 r 1995 COMMONWEALTH LAID TRLE INSURANCE CO. SUft%W/NOM N FLORIDA,A NATIONAL ASSOCIATION, Building and Zoning LOT I OCEAN BREEZE DRIVE NAw �>Z u'1 � (PRIVATE ROAD) N89•-43'-35"E 60.00' c L30-CA6EMEW FOR MOREK 4 COMM DRAINAGE A!D UTLMES 'r rAVW<i .� yr ,CURS AND GUTTER f 240 1 1 Q M oc tFm ti. 0 i O LOT 10 4.0• 0.r ' IR 431 4A' �1 r•, ty ®12•r ^, 0.4 © ` 0 POOL NOTES: 10, o O EE 00.t '�? w > SEE ATTACHED POOL PLAN ••opt N FOR WATER D£PCH. co rc- > SE£ ATTACHED POOL.PLAN W u� 10 WE o FOR DIMENSIONS TO ALL Z 4z O COV£R£D 6TIWC-TURE3. m 0 1 > S££ ATTACHED POOL ULAN N Z ! .~1 13.4 7.01 FOR ANTI-IrNTV"MONT AND w DARWEF-CODE COMPLIANCE. DECK Q00 L out 60.00' of s S89•-43'-35"Wc,,m 0s' p 1 none 1 r"`' Lw Rev. /-.70 -fr el W=EMN Na 140+ WMW 12+14 TO Mw rim K )� 0.8-"vuw#w RIM""7-r.A-04,v swyw.cw.cm" 4p 15 MIN. FTURM PHONE #._ $�� NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE Permit No. Tax Folio No. �j State of County of co in To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property, and in mS accordance with Section 713 of the Florida Statutes,the following Information is stated in this NOTICE OF G. COMMENCEMENT. N t7'�` /f Legal description of property being improved: L 1 Breezc 0+ d rt Address of property being improved: t3o OC ecz.i G A /Cl i-f'+c- Scii, 12_ a2-7-3-3 General description of improvements: Tn»n),xei d 60 Owner—Lam4 IJahO)aLD Address `7 0 (CE'a,n JB teC-2-G t Owner's interest in site of the improvement eco Fee Simple Titleholder(if other than owner) Name Address Contractor 'I C. g2,-A- - /_% � {f C,,t�, 100Q/,T 3.0 e- - Address 9-3 O "J-PK. -32zz Phone No. (9 0q) FS-.s` 6()!q Fax No.(qyq) 893`_ OFA Surety(if any) Address Amount of bond $ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06 (2) (b), Florida Statutes. (Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): TW IQ Quer-C cno o�rncnec �ii��n:-v—I IA/CSG TIC CITY00 SEMI OLCH E ROAD ATLANTIC BEACH,FLORIDA 32233-5345 TELEPHONE:(904)247-5800 FAX:(904)247-5805 SUNCOM: 852-5800 http://ci.atlantic-beach.fl.us PLAN REVIEW COMMENTS ENTS Permit Application # p Applicant: C-1-AFT Co • oLZ 4 Address: p E R1--- Project: oL4/our application is approved o Your permit application has been reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed by Signed Date "/g'/73 Contractor Notified Date Mar 24 03 02: 25p Building Department 247-5845 p. l CE 03-e2(e( oa z' CITY OF ATLANTIC BEACH iA`, l 6 2003 POOL PERMIT APPLICATION i Datc: �nJ j Job Address: y ��'e � ,Z I H'�"/Q-.'►`� Owner oi'Property: La' 7 tJ&Lhe� Telephone. j a(/7 - Pool Contractor: E+-1 (z Ai. C%' } Contractor's Ad dress: Telephone: 005-Y' oo ji Fax: / NJ ks:�-'D&9Q State License Number: —0—10C.vb(0 3 Valuation of Proposed construction: 5 Fallons: v v" S1TF.PLAN front. rear > Signature of Owner: Signature of Contractor: 800 Seminole Road-Atlantic Beach.f lorida 32233-5445 Phone: (9.04)247-5800• Fax: (904)247-5845. http://WWW.Ci.2ti2ntiC-bC2ch.tl.us Revi-sed 1/14/03 nar icr uj uf. .jlp buiiaing uepartment e4I-b8l4b p. 4 P7 7, OWNER'S AUTHORIZATION FOR AGENT 6 20 Ri C11 + Cb-- 6 is is hereby authorized to act___ on behalf of tjogsj-)aLD the owncr(s) of those lands described within the attached application, and as described in the attached deed or other such proof of ownership as may be required. in applying to the City of Atlantic Beach, Florida, for an application related to a Development Permit or other action pursuant to a: 0 Zoning Variance ❑ Appeal ❑ Use-by-Exception Fence or Pool Permit ❑ Sign Permit ❑L Rezonin%' Plat or Cpl t ❑ other BY Sxgnaturc f qwner Print N- e Signaturc of Owner Prin tName Telephone Number State of Florida County of Duval Signed and swom before me on this._�_dy of,200_-) By_ Identification verified: 1J r LA[, Oath sworn: ---Ycs No atu.rcHWEAATHMD. Lli My COMMISSION ff CC 910738 14,20N MapOutput JAXGIS Property Information I 2424 240 2M 121 1i5 1#IiF gi 51 235 1 9088 5 so 90 70 234 2389 2375 23N;: 2341 2"1 236323" 2367 2371 _ 369 2332 2335 AN 235 2320 Copyrig hi f C120M C ky of JaGksonvilk,F1 �I M 14 8 f t� l E# Name ddmss Total cr9es lot get �l Desortptlons Oo dUse Zoning T II ALSHAW EAN BREEZE DR 6-51 37-2S-28E 168908 825 RRY£ 80275 2 3 EAN BREEZE REVISED P!A 0 233 0711 ryh 5/19/2003 PREPARED 8/27/03, 8:03:48 INSPECTION TICKET PAGE 6 CITY OF ATLANTIC BEACH INSPECTOR: LARRY J HIGGINS DATE 8/27/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 90 OCEAN BREEZE DR SUBDIV: TENANT, NBR: ALUMINUM SCREEN/POOL ENCL CONTRACTOR TROPICAL ENCLOSURES INC. PHONE (904) 241-2298 OWNER WALSHAW, LARRY E PHONE PARCEL 168908-8255- - APPL NUMBER: 03-00026575 SCREENED ENCLOSURE ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ 16 01 8/22/03 LJH BD FINAL TIME: 13 :00 8/25/03 APCREEN ENCLOSURE - 247-0021 16 02 8/2703 LJH041-2298 D FINAL TIME: 08:00 -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY O s d81 � , Office O'i suiijiingg Offid"li { C-rs [Y6p Date. - -/~/ - - Permit No. Tur-.tt A.IV P c0 ve - P.MM /� O 410`Amer'�� , �'qss Locality 1 Ct�NCFETE _ i�LUPABINCa 7ECHANICAL Framing Footing Rough Wiring Rough Air Cond. & fie Roofing i Slab Temp Pole _ Top Out Heating Insulation Lintel Final Sewer 1 Fire Place e Fab READY FOR INSPECTION A.M. Mon. Tu.s Wed. Thurs. a AIM ST�iVSP t Inspection Mad /✓- _ — --__.--- -__-_ .Mr` Final Inspection 1) Gertific�.te o ccupancy �U �� / Date ! PREPARED 8/21/03, 16:24:21 INSPECTION TICKET PAGE 10 CITY OF ATLANTIC BEACH INSPECTOR: LARRY J HIGGINS DATE 8/22/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 90 OCEAN BREEZE DR SUBDIV: TENANT, NBR: ALUMINUM SCREEN/POOL ENCL CONTRACTOR TROPICAL ENCLOSURES INC. PHONE (904) 241-2298 OWNER WALSHAW, LARRY E PHONE PARCEL 168908-8255- - APPL NUMBER: 03-00026575 SCREENED ENCLOSURE ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESQRIPTION TYP/SQ COMPLETED RESULT /LTS/COMMENTS------------------------------- ------------------------------------------------------------ 16 01 8/22/03 LJH INAL TIME: 13 :00 2 -12 EN ENCLOSURE - 247-0021 -------------------------------------- COMMENTS AND NOTES ------------------------------- 2 FI94 : TROPIC FAX NO. : 904 247 9241 May. 29 2003 09:04AM P1 Hook 11244 PA90 614 5. MIN. RETURN PHONE# 2� NOTICE OF COMMENCEMENT State of Tax Folio No. County of To Whom It May Concern: ����� � The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: LO 7' / ! t-�-IAti P-qOA?�/' �0 - Address of property being improved: N ' t z -4 General description of improvements: c.L'+'M M r- ice' Owner: 1'1^ LFA Address: 0 i-J �- Owner's interest in site of the improvement: Fee Simple Titleholder(if other than owner): h1 J A Name: 1-j/FY Address: �IA Contractor: �'^ �� �" Address: k- A v !Ct. Phone No: '7-41 Z'L`14Fax No: Surety(;f any): Address: e .t C` Amount of Bond$ Phone No: Fax No: \` Name and dress of any person making a loan for the construction of the improvements. Name: Address: 14 Phone No: Fax No: Name of person within ihe State of Florida,other than himself,designated by owner upon who notices or other documents may be served: Name: 1�� Address: k-4 A— Phone No: Fax No: In addition to himself,owner designates the following person to receive a copy,of the Lienor's Notice as provided in Section 713.06(2xb),Florida Statues. (Fill in at Owner's option). ` Name: v'j na \-\I '7 .: vL� Address: rl '-'N 4�- 771,S-(JC Phone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year f m the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLYn OWNER Signed:t•-11 / J Date: Olt,.� hfureme this day of Tr _ii the County IloeM.i01 41269 l,St Florida,has persooaily appdared b lc lie'at Lar e,State'of Flor LlL"LRecored Y g { ,.�A>� 07/P5/ti'D43 03:36:32 PN My commission expires: ", r ttoctttiow 1IM FILLER personally Known: ItMA r. e or Cl FA CIRCUIT COURTWA CM ' produced Identification: ; . � tloredod thcocrpt► REDI1(6 TRUST FLO 100 copy FEE 1.00 CERTIFY CITY OF Office of Building Official REQUEST FOR INSPECTION Date Permit Permit No. Time A.M. Received s P.M. �C Job Address Locality Owner's 4PContras G +'* DIN CONCRETE ELECTRICAL PLUMBING MECHANICAL raming ❑ Footing ❑ Rough Wiring ❑ Rough C Air Cond. & ❑ Re Roofing O Slab ❑ Temp Pole Ci Top Out O Heating Insulation -, Lintel ❑ Final n Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION A.M Mon. Tues. Wed. Thurs. Friday A.M. Inspection Made P.M. I pector Final Inspection Certificate of ccupa cy Ej 3 Date n/���//����,� //CITY O77V //F / �_,��- �' �- Office of Building Official REQUEST FOR INSPECTION Date----?— / — a Permit No. Time �/ r M. Received Job Address Locality Owner's Cj N e Contractor } BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring F] Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final ❑ Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. MTues. Wed. Thurs. Friday P.M on. A.M. Inspection Made ✓ PM. Inspector L Final Inspection Certificate of Occupancy ❑ �dfS�1 WLAAN " f— — �1�.1� + Date k P�LANr��, _ t`- c) G) _ OF ADDITIONS or CORRECTIONS D• NOT REMOVE JOB ADDRESS DATE THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted C L 1`A) $15.00 REINSPECT FEE Y It is unlawful for any Carpenter, Contractor, Builder, or other persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time of approve the installation. After additions or corrections have been PLUMBING made, call 247-5826, Building Depart- ment for an inspection. Field Inspectors ELEC are in the office from 8:00 a.m. to 5:00 SLOG p.m. Monday through Friday. Back V a left, 5 MIN. RETURN l Boob 961 Page 6186 � dot ce of �vmmeneemen�t PHONE# (PREPARE IN DUPLICATE) To whom it may concern: The undersigned hereby informs you that Improvements will be made to certain real property, and in accordance with section 713.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Description of propertyar _ Q� E�`n`L�/� _1�Q _� �'ct_o�1__1 -----------------------------------------------7----------/---------------------------------------------------- General description of improvements ,4'f�/_l _..c_ -I/- ---------------------------------------------------------------------------------------------��-------------- Owner _ rT -ll-��� ��-------------- Address G �� IL' Owner's interest in site of the improvement --/_�S,_.._t.1f`_ t0 _________________________________ Fee Simple Title holder (if other than owner) ----,�11q- --------------------------------------------------- Name ---------------------------------------------------- Address ----------------------------------------•------.._.._-------••---------------------------------------- Contractor -- �a�h-(J---- J - ---- �. r.---------------- Address --- t C.?�-1z_ 5_ _=__ ..__ 1 __x��cz`_�1 � ------------•--------• i Surety (if any) -- --------------------------------------------------- i Address --------?---------------------------------------------------------Amount of bond $--------------- Name and address of,aany person maki)n a loan for the c nstruction of the improvements. Name --- _ L (�1_ if---�� I ---------- ---------------------------- Address `F�tJ--L--1•=--- -���- ------------------- Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name _, 1[1_Lr'_ �l_/�h,1 QC�___5.e_�/_� A/111,l_!_��1-------------------------------------------- AddressL1 _�- ----------------------- l- In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06 [2] [b], Florida Statutes. (Fill in at Owner's option). Name ---------------------------------------------------------------------------------------------------- 1 CITY OF r�t�°a�t�c z�Seacl - �eazida `1011 SF-MINOLE ROAD _ ATLANTIC BEACIL FLORIDA 1221; ,,-I� - TLLIiYHONE 0041 1_17-5800 FA.A i W4- '4'-580 999 David W. Miller Aluminum Constructors 2083 Nickerson Lane Jacksonville, FI 32207 Re. Required Inspections for Constiuction In the City of Adan do Be&ch Dear Sir: Please be noted that a review of our records reveals that no inspections have been performed at the following addresses: #17618 982 Ocean Boulevard #14326 1989 Selva Marina DriveO #12919 1822 Selva Grande Drive #11376 75 'West 13th Street #10955 #10425 347 Third Street Our records indicate that telephone calls have been made to your office on several occasions. Please arrange for these properties to be inspected as soon as possible. My next communication with you will be in the form of a Complaint against your license to the Department of Professional Regulation. Please call me at (904) 2475826 if you have any questions regarding this matter. Sincerely, Don C. Ford Building Official DCF/pah cc: Homeowners 16570 r I DEPARTMENT OFAUI0INQ ciTYQE atI.A1�1TIC 6i~mcH PERMIT, I. FORMAT I CN LOCATION Y NPORI4AT I CSN t umbra: 167{} A dres'a SCI OCEAN BREEZE DRIVE ., LZIAL DESCRIPTION ------ Ca t m Type: OOD FRAME B1cask, t,c►t. 11 Twp; � + 11in'g :.� . . ubdivisi OcrAN ap.EEZE Improv cost 0 Tat l Fees 1 145 .00 i X19 De '1 AT�If N NETER I" APP L I CA`$'I LAN FEES t � lSAN ,00 AD ATF,R IMP1�C I"LEGk� 01 r ,+ �I►CR 1,DA 2 2 �I:� P �- ,> t /� .�* +} � . "'x 1n �,ivl- x� `2"" �w.c ♦`v- ittr` l7 WAS G7 ,i�r f'1.a L"7 0 .0 C*, '[ � www+ p"1, �{'�,�.a.■ _ `sr' 8 I L T_ " N d: DE RTMEN'T $ _< API TAD IMFR€�U'E. 0 0d EWER hl? ,., fl ROSS CO MECTION ' Exp: N' ( u � NOTICE+INSPECTIONS, MUST"BE REQUE�TE©,11T r�EpST 2"4 HbURS PRIORTO INSPECTION Ut 0f"tVf MATERIA ,RUBBISH AND PEBRIS.FROM THIS ifORK MUST NQ7 BE PlACEO,I F?UBLIC S 'ACE,ANS MU$ $E LEA ED UIQ AND HAULED AWAY BY EITHER CO RACT09 4R OWNER. �� f SAIL J E T comp 1M17N THE IV ECHANICS' 1>r1E1�1 LAW .CAN I S1 �T 11 C)PE TY C3 Iw E R pAYI All T1 V C,E ]FORS 1 004M ISSUED ACCORC}iN TO APPROVED I?LANB WHICH ARE.FAR OF'TH'i , PEFtMIT�¢11D`SUBJECT TO'R VQCAItO# t R M �Ttf fil QFxAI P CABLE f�RC+iIkSLQNS CSF LAW. � tl�lrator: tot;�2 Paytt i1i��»�� ATLAC TIOSEA I BUl `ERIN DEPARTMENT i 9� . , , . Jura-01-98 10:27A Harrrry Mc Nally 904-247-5872 .01P.01 01 O1 ma-V-29-98 03: 16P P PRIME QUOTE APPLICATION FOR WATER ANDIQR SEWER TAP ♦ r r APPLICANT NAME MAILING ADDRESS 4,6 PHONE NUMBER 7- 3 2--l i DATE__„_, SERVICE REQUESTED SERVICE LOCATION ,� DATE SET TO PUBLIC WORKS--) DATE RETURNED TO BUILDING DEPARTMENT PUBLIC WORKS DEPARTA/ENT PRICE QUOTE RESPONSE WATER: t; " 4' SEWER; - OTHER: PRICE QUOTE PREPARED BY: Signature- Title OATS NOTIFIED OWNER x DEPARTMENT OF BUILDING CITY OF ATLANTIC 13FACH ., u PERM17 I NFOR,MAT I ON - LOGAT I QUI T NP4RMAT CN P i t Numb rr; 1546 3 Address: Q 3C s E xE E � let Typel,ZLECTRICAL ATLANTIC �A3 fit CH, �F'L0kiDA 32233 C1: ss of Wo :ALTERATION LEGAL, DESCRIPTION ams tr. T'yPje*WOOD FRAME �, _B10C'k Lot* 21 Tw t a 11 n r, h Su divisio „OCW BREEZE J Est , Val4e, 0.00 1'*Prov. _Cos 0.00 ' Tcatal Fe 25.00 m Aarc unt 25 S.00 ; ON ---- API?LIGA'T#UN. FEIrS - _ R�� m e,*A, yp E WALSHAW F I"1' AD yI FLORIDA 3,_ kFw , Iffic e_ HAD ', . r i M bbL . � Ir 32050 ���' , T � x � NOTES: � t m ¢g }NO 1� 2` • IcE INSPECTIONS MU6T BE,REQu6�TIED AT LEABT24Hous PRroR To rNst�a<� � } BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS ©RK MUST NOT BE PLACED IN PUBLIC SPACE,AND=MU f BE RACT } CLEARED UP AND HAULED AWAY BY EITHER CONTOR OR OWNER c� ETO COMPLY- ITT THE ECHA��� � LIEN RE a� 11. � lk `PROPS TY OWNER PAYI"NG TWICE FOR B�l�L�1�IN I R i tB 1>:p ACCORDIN. TO APPROVED:PLANS Wh ICH ARE PART OF THIS PERMIT AND SUBJECT TO RI+v6. , T C}N QP APPLICABLE PROUISIONS QF LAW. .ATL TIC ACH BU LDINC DEPARTMENT CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:--Aof� n 19 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. A"C ELE TRICAL FIRM: MASTER ELIECTRICIAN SIGWAfURE NAME _ ADDRESS: (% C� �� RFD BOX BLDG.SIZE BETWEEN: RES.Vk APT. ( 1 COMM.1 1 PUBLIC ( 1 INDUS. ( 1 NEW( ? OLD ( 1 REW. ( 1 ADDITION 1�r TRAILER ( 1 TEMP. ( 1 SIGNS ( 1 SO. FT. SERVICE: NEW( 1 INCREASE ( 1 REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COPPER ALUM. SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE C90 AMPS PH 3W a(10 VOLT S 06"ACEWAY FEEDERS NO. SIZE NO. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS. 31.100 AMPS. SWITCHES 7i- INCANDESCENT OdC T — 1 4 - 97 T U E 10 : 1 5 C U S T O M DESIGN P 0 :2 ARCHITECT/ENGIMERS CERTIFICATION COASTAL CON-Q-MWC'r10N r=nrL-Foa AL1._MaJQB- sT$[cznkES TO BE LOCATED WITHIN CITY OF ATLANTIC BEACH, FLORIDA APPLICANT'S NAXE Mr. & Mrs. Larry Walshaw 2HONE NO.725-99213ATE1 0 /15/97 OWNER NAME Mr. & Mrs . Larry Walshaw R.E. TAX NO. : TYPE OF PROJECT: ( )New Home )Residen_tial Addition ( )Garage ( )Pool ( )New Commercial ( ) Commer on ' FR 911 STREET ADRESS• 0 Ocean Breeze Dr Atlantic Beach ( } We claim the _ follows: (. ) Garage with no provision for occupancy - detached one and two family only ( ) Fier, Dock, etc. .e' ( } Other (Specify) I also certify that no structure listed above may be remodeled or converted to a non-exempt use without being upgraded to fully ccmpLv with the ordinance. Signed: Date: ---------------------------------------------------------------- CERTIFICATION This certifies that' the plans and specifications submitted and sealed by the undersigned .meet all criteria set forth by the City of Atlantic Beach Coastal � Construction. Code. Roof covering is exempt from the 110 mph requirements of the Coastal Construction Code, but meet all the other requirements of the City o'f Atlantic Beach Building Code. ( X) The structure including foundation, frame, roof decking, exterior walls and floors has been designed for wind loads of 110 mph, with all design complying with the 19 , Chapter 31606, Standard Building Code. --------------------------------------------------------------------------------- ( ) Windows, doors and all other exterior devices comply with the 110 mph wind load. ------------------------------------------------------------------------------ ( ) The structure is located out's_de the area affected by wave forces, OR ( ) The structure is capable- of withstanding wave forces resulting from a wave crest height of feet above MSL including uplift forces. ------------------------------------------------------------------------------ ( ) The structure is located in F_n Zone A and the foundation design has considered possible exposure to water and erosion, OR ( ) The structure is located in FIA Zone X and the foundation will not be exposed to hydrodynamic, hydrostatic loads or water scour, OR ( ) Foundation design has been completed with floor elevation above the specified stillwater elevation, and to resist wave, hydrodynamic, hydrostatic and wind loads acting simultaneously with dead loads. Erosion computations for the foundation design have taken into account the projected 30-year erosion losses from a 100 year storm event and all vertical and lateral erosion including scour caused by the structural components. ------------------------------------------------------------------------------ ( ) No excavation of dunes is included in this project, OR ( } Dune excavation permit is attached. ---------------------------------------- ---------------- Cerzified thi , 15t1iday of October 19 97• (SEAL) Fi a Archi ct's L' ense No. 7Prossional Enginee License No. 40177 110tice of (OMMentement (►IIatA�a fN oU►Lte�Ta1 To whom it may concern; 4 d The undersigned hereby itsforms you that Improvements will be made to certain real property, and in accordance with section 713.13 of the Florida Statutes, the following information is atated in this NO'T'ICE OF COMMLPNCEMENT. Cn CL 90 Ocean Breeze Dr. , Atlantic Beach, FL Description of property I AKA Lot 2, Revised Plat of Ocean Breeze t as recorded-in Plat Book_46a_ Pages_ _____ ____-____-__.____ ________. _ ._.___________________ ------------------------------ to 51 & 51A of the Public Records of Duval County, FL ---------------------------------------- ------------- 0 General description of improvements __Room AdQT3_1Qx],.4_Ro. isting______..__.._ a4 ___-- 2nd Floor 0ULd.QP_r__Peltasz___-__..___-__----._..---------------------------------------------------- Owner _Uj_cbell."-1.a.rr*_leTa.lshaw----------.---------------------_--_---------_.---------------------_. Address _90 Ocean Breeze Dr. , Atlantic Beach t_FL--32233 ----------------------------------- ------------------------------- Owner's ----------- ----------------.Owner's interest in site of the improvement _XPg_UmP1g_________..______________.._-------_--_..__-----___. i'ee Simple Title holder (if other than owner) _Same-------------------------------------------------------- 1 ^� Name ---Same---------------------------------------------------------------------------------------------- (1Y� Address _-__Same -_-__-..______________.._..___--_-____..----------.._-----...._-------__.._-------------_----_. CE, Contractor _-Cavalier_�Qn t, y�F Qp Assoc._ IncL_.-....___-______.___________________ ________ wAddress 250 South Roscoe_Blv_SL.._.,_Ponte_�1e -------------------- -------- Surety (if any) _NLA-----_--. LU Z Address ------------------------..__--__--_________ ------Amount of bond $__-_-_ = Name and address of any person making a loan for the construction of the improvements. a' Name _Self --------------------- Address ------------- --------------W_--------------------------.--------------------------------------_. Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name -ILLA_-------------------------------------------------------------------------------------------- Address ------------------------------__-------------_----------------------•---------_--------------------- In addition to himself, owner designates the following person to receive a copy of the Wenor's Notice as provided in Section 718.08 [2] [b], Florida Statutes. (1111 in at Owner's option). Name __J JA------------------------------------------------------_---------------------------------------- Address -----------------------------------•----------_---------------------------------------�---__ TMIe eF'ACR NOR M19C)RDaN'/ UiR ONLY ' Z L s` pEf ">*TMENT OF sulo1Nt4 • CITY OFOLANTIC BEACH a PERMIT INFORMATION - � � ��'_.... LOCATION ;INFCRK*TI pt'' m t Flambe` t 15407 Address 10 Oc SERE .A ' Permit ;Type;.R06M ADDITION ATLANTIC SEAC23 , FLORIDA 32233 class t3 Nor ':ADDITION - - - - LZdAL DESCRIPTION C Tistr f :TY1�'e,:WOt'D FRAME ,Bl ock*�' Lot:; 11= Ptoposed Use: Sections t? Subd:;p Rn r: 0 , Dwellings: 1 Subdivision:OCEAN,,: SNEEZE E t , vol e# 0.00 Tmprov.' Co Total Pe 5. ! °"Amount ,' h ,e 16 ,Cd at, 97 r� q Wort ��� s RoomEJR PLANS h ION _. :�� a nr � :_ APPLICATION <PERS'. 'NALSSA "'. 1 .00 S dd>r ROAD ' B � FLORIDA Pion•` f 5 4wt .,., { A E ORMAT I(0, .. ;r ri /�y;f BreeH �'A1��� L� �� CMS DG*1'�C�M��� INC LEART °:,. PONTE V BEACH, FLORIDA 32,682 � , '" �" , y �� G ^ ��04,"*p,. ,I F#.+."mow.x..xaaeu�at; w#iyw.. a,,, .. .,.,. , ar�+� r,* w, ,.�.>,,.,,r;• NOES: s i w a a NOTICE-INSPECTIONS MUST Int REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BI ILDING°MATERAL,RUBBISH AND =FROM,THIS WORK MUST NOT SE PLACED IN PUBLIC SPACE,AND MUST BE G � EARED UP AND AWAY`BY E9THE1�CONTRACtOR•�R OWNER, J ' FAILURE Q COMPLY WITH THE; AECHANICS' LIEN LAW CAN RE U ' lft� T`H E PROP RTY OVWN E R IAYI N TIIC E F ►F Btu I L111 Imp RUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF;THIS PERMIT AND SU ECT TQ AEV ©R i . VI TION O AP DLICABLE PROVISIONS Of LAW. bate 15/9791 . i 1R1 3221W ATlNTlC EACH"BUILDING DEPARTMENT By, i.C. ..a;A "'�.i"."^,'-ice,,,. lr hoc.FLL,.B...'1."1'. 0.z:4 .a ':3'2; 2,9dIPtiZ1D`- :rwkv'a k_ ",x.✓. nx. .a __xu. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION [:FORM 60OC-93' Residential Limited Applications Prescriptive Method C NORTH 1 2(all Additions and Renovations Department of Community Affairs Compliance with Method C of Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the Use of Form 6000-93 for additions of 600 square feet or less,site-installed components of manufactured homes,and renovations to single and multifamily residences. Alternative methods are provided for additions by use of Form 6006.93 or 60OA-93. PROJECT NAME: BUILDER: I I e Car 0 AND ADDRESS: n n PERMITTING CLIMATE + OFFICE: C1.i p}-A+I 6Gl'1 ZONE: 1 ❑2 ❑3 OWNER: t.£ �shc�f.J PERMIT NO. 5 C f O JURISDICTION NO.: 2 � 1 Dy SMALL ADDITIONS TO EXISTING RESIDENCES(600 Square feet or less of conditioned area). Prescriptive requirements in Tables 6C-1 6C-2 and 6C-3 apply only to the components of the addition,not to the existing building. Space heating,cooling,and water heating equipment efficiency levels must be met only when equipment is installed specifically to serve the addition or is being installed in conjunction with the addition construction. Components separating unconditioned spaces from conditioned spaces must meet the prescribed minimum insulation levels. RENOVATIONS(Residential buildings undergoing renovations costing more than 30%of the assessed value of the building). Prescriptive requirements in Tables 6C-1 and 6C-2 apply only to the components and equipment being renovated or replaced. MANUFACTURED HOMES AND BUILDINGS.Only site- installed components and features are covered by this form. Please Print CK 1. Renovation, Addition or Manufactured Home 1. pg�;w ifiar) 2. Single family detached or Multifamily attached 2. 3. If Multifamily-No.of units covered by this submission 3. iy ) 4. Conditioned floor area(sq. ft.) 4. 140 5. Predominant eave overhang (ft.) 5. /•8 6. Porch overhang'length (ft.) 6. N/4 7. Glass area and type: Single Pane Double Pane a. Clear glass 7a. sq. ft. sq. ft. b. Tint, film or solar screen 7b. sq. ft. 28 sq. ft. 8. Percentage of glass to floor area 8. y % 9. Floor type and insulation: a. Slab on grade (R-value) 9a. R= sq. ft. b. Wood, raised(R-value) 9b. R= sq. ft. c. Wood, common (R-value) 9c. R= '352 140 sq. ft. d. Concrete, raised (R-value) 9d. R= sq. ft. e. Concrete, common (R-value) 9e. R= sq. ft. ' 10. Wall type and insulation: a. Exterior: 1. Masonry (Insulation R-value) 10a-1 R= sq. ft. 2. Wood frame(Insulation R-value) 10a-2 R= k9 258 sq. ft. b. Adjacent: 1. Masonry(insulation R-value) 10b-1 R= sq. ft. 2. Wood frame (Insulation R-value) 10b-2 R= sq. ft. c. Marriage Walls of Multiple Units* (Ye No 10c 11. Ceiling type and insulation: a. Under attic(Insulation R-value) 11a. R= 30 1'tQ sq. ft. b. Single assembly (Insulation R-value) 11b. R= sq. ft. 12. Cooling system* ii (Types:central, room unit, package terminal A.C., none) 12. Type: %Q✓ rcr--l SEER/EER: 10 13. Heating system*: 13. Type: 44ezJr Pum( (Types:heat pump,olec.strip,natural gas,L.P.gas, room or PTAC,none) HSPF/COP/AFUE: 14. Air Distribution,System*: a. Backflow damper or single package systems* (Yes/No) 14a. b. Ducts on marriage walls adequately sealed* (Yes/No) 14b. 15. Hot water system: 15. Type: IJ l 40� (Types:elec.,natural gas, other,none) EF: "Pertains to manufactured homes with site installed components. I hereby certify th theplans and specifications covered by the calculation are in Review of plans and specifications covered by this calculation indicates compliance compliance with Florida Ener y with the Florida Energy Code. Before construction is completed,this building will be PREPARED BY: DATE: 9 inspected for compliance in rdance wi ecti F.S. I hereby certify s bu" is' ce with the Florida Energy Code. BUILDING OFFICIAL: OWNER A DATE; DATE: RECEIVED CITY OF ATLANTIC BEACH OPT 1 1991 PERMIT APPLICATION R 40DEL, ADDITIONS, OR jkftPR4;;PKSBeach MOVING,DEMOLITIONS Building and Zoning Owner (s) : Address: &Irnpl Phone: ` �� Lot # Block or Unit # Subdivision: Contractor: �G /3�C'( hi i' i f�A)s 0"') State License # �f�C fjSZ3f� Address: 2:M d. eoS[ar£ &Ilp Phone No: ���-��7'� � -73 --51 7f City I427 AAI% ,q State rL Zip Code a Describe work to be done: ?resent use of building: Valuation of Proposed Construction: �� L1Z'fZJ� -T Proposed use: Is this an additicn? YeIf _yes, what are the dimensions of the added space: /0 -m ft. X ft. Wi11 the added area be heated and cooled? New electrical (or increase) ?tlk New plumbing fixtures?� New fireplace?/Vo New Heat/AC? 46 SUMMIT TUFO; (COD41ERCIAL) TWO (RESIDENTIAL) COMPLETE SETS OF PLANS, INCLUDING SITE PLAN, SURVEY, ENERGY CODE FORMS, NOTICE OF T, AND OWNER/CONTRACTOR AFFIDAVIT, IF OWNER IS CONTRACTOR. Signature CWNER: Date: Signature CONTRACTOR: Date: LQ 67 Sworn to and subscribed before me this day of 19�y 4 1 � �Ca�1 +\ NOTAAY PUBLiC STATE OF F AT Iu18�agm OfletEs C\x ' MY COMMISSION M CC553881 EXPIRES Auguyy �� 27,2000 BONDED THRU TROY FAIN INSURANU,INC. V) l CITY OF ATLANTIC�jBEACH PERMIT CALCULATION SHEET Address 96 /�LFFZ Fz (17- . Date-4 - I'S Heated Square Footage @ $. per sq f'; = S Garage/Shed (a $ per sq f _ = S I Carport/Porch@ S per sq ft = $ vv.. ttt Deckad 4 @ S per sq ft = a Patio �S ©� �TI @ S per sq ft = S mm TOTAL VALUATION : S --fid-�°`' V © 0 Tctal Valuation 1st $ 100 Rema ning Value $ per thousand o portion thereof TOTAL BUILDING FEE $ /�OO + 1/2 Filing Fee $ © _ ( ) Fireplaces @ $15 . 00 $ BUILDING PERMIT FEE S S�dZ) WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT S SEWER TAP S (, 1 RADON (HRS) . 0050 S SECTION H PAVING HYDRAULIC SHARES S CROSS CONNECTION S ) SURCHARGE . 0050 S OTHER $ rr\\ GRAND TOTAL DUE S (p ®V ADDITIONAL PERMITS OR FEES : Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank ;Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES : p r r a i r .- QEf►ARTMII:NT Of BUILDING s CITY OF AtL:AN'TIC BEACH ERM }k ti fl 'C ATION _.� __- LOCATION INFOIAT I ON P��'ICt1t Nr I 15481 Address: 90 OCEAN BREEZE DRIVE rmi t Tp :MXCHAN I A ATLANTIC BEACH. FLORIDA 12233 Ci0st cif" Her -ADD I I `24M LZOAL ,MESGRI PTION - -- . _� , C16nstr. TyP{i{"HOOD PRAML, ook .Lott Twp Pjopos'ed Usie: Septi on 0' iiA,:0 Rrzq t} DwelI`ing t 1. S bdi. s .00a.CtCEAN BREEZE :1 Est ., Valu w C I ipr6v. Ccs Total Fe tctn t " ' s t .A 0. ;u _ s a r � , It l - -� �_ ,APPLICATION ,FESS - Nc3@., . , . P�RI�!'I T } Ad r: EZE DRIVE �� � 125 C 41p + f'1Rd' s 4 1F��aM.. �' .w [ ;, �p Ilam : OC N HZAT & AI 3 Ad �,:,. l + I"C "RLS" .. _ EP' PLCRII3A 3.2233 d I , f t j NOTICE , INSPECTION$ I**T QE"$TEQ AT ILEABT 24 HOUpS PRIOR TO INSPECTION A n F 6 } SUILMNG.MATERIAL,L,RUSMSH"ANLL DE6Ai$F.Rbm THIS WORK MUST NO, ACED W PUSUrSPACE,AND MU$T`BE GLI BRED UP ANO` A AULED AWAY SY f.T't*IEI .CON TRAGTQR UFi OWN , LTI THE=PROP 0 R p�� N TWft ■ IS kED ACC©RDI. G'TO APPROVED PLANS WHICH ARE BART' OF THIS PERMf ANA'SUBJECT TO REVOCATIC�N ATION OF APP IC/kf3L.EPROVISIONS OF LAIN. t I sy SEAGH 8' lDl G ,; PRRTMENT � y.vl" BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC 11111ACH,FLORIDA$taaa APPLICATION FOR MECHANICAL PERMIT CALL•IN NUMBER IMPORTANT—Applicant to complete all items in sections I, 11, III, and IV. I' 9d Oc�AN REEZE G+- LOCATION st„.1 Addr.w: IF fak""Nae skroel6t 101.000 011 1W0LE A.I E AN 8 REEZE WILDING fo►•ILMI.. II. IDENTIFICATION—To be completed by all applicants. 1. ce.ridveGon of M..i/I;.on to, doing IM work./dost,;"d in the ebow /INemeot we hereby 89,04 to p.rlon.qld.ort In.cc ardente .H. the ettoclyl 0406 and 1110044160AI which am a Port hv.ol and is accordance with the City of Jacllonville ordin.ncel end d.nda,dl d 1"d 0•ac Nee lilted/AorefO. law .I M"I aokel GatraeNn C...eetw (ni.#) ©C N �tTr�� h+.11.. c. coL39 318 Neve a 0.ovwov Geer S yp.two of o.owt Itl.alere of r Aeahariol Apel of a/gl.gr 111, ifNlrlAL A. Tyer.01w 10 OTNtIt CONOTIMlCTION pitons OONt OM O electric THIS WILDING ON SITS I O "—C3 u O O C-W UNWy 0 of 1r rte,e1Vt IIWIOtN O/WKSTt1UC ION PtNMIT O ol►« — $Poe* IV. bOOKANtCAL apUMAIW TO M OWAJIM RATURt OF VIONK (p" M.o"rpl.a a" '�M W.�t►II ) O 14Ndentlal or O Commercial D Nast O 1r.« O te+eaad O Cw*W O 11~ O New Ilulldlna O Air Cootie isel"t 0 tea. O Ceawd O txlNlrla tWlelnO Q 000 sy.l..I: - tye►,,.K— O INNaanwM of eiileting eyelNll Y.ahaoot"os"nlr alw O MetsMIlOn(N0 eyalan pMeuely Instog ) O �— lenelen a add-on to e>tlet.4 elan O C -r-e Is 00 CareaMy I 01M►_peaky (�d c� v G+ Q�}N t►•�w O Rt WanwN: N ►ae of ►--�' O i4.wew O memo► O wale/e.. (+e*►er) 1/N{>M1ACf 1'OR Mlles IIM M111! (3 0*2460 D T.a.a Ind t.aNl►. O LPG (ewtlsNei O Uobel r..w.VON" O Sees" Perked AMleye/ 1r O ol►.—M+aM Perele a.� usfr Au zgtnr z rr Ali COMM10"ING AND ROIR MUT10N CQtWWMt N+arh.v.1b. Deaelteuet taa,1 tTllnNr ] (Tan) 1 1 MATING • IURNIACM DOUJJM/IRf/LACU JTNuhe VMS i1M Ilella►er Q' j TAKU !M NW ROad N"� i 1< 11 mer saw lig Climate Zones 1 2 3 TABLE 6C-1: PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDITIONS(600 Sq.Ft and Lits),RENOVATIONS TO EM71MG BUILDINGS AND SITE-INSTALLED COMPONENTS OF MANUFACTURED NOMEi MINIMUM INSULATIONMINIMUM INSTALLED COMPONENT INSULATION INSTALLED EQUIPMENT EFFICIENCY EFFICIENCY Concrete R-7 Central A/C-Split SEER = 10.0 SEER = J Frame,2'x 4' R-11 -Single Pkg. SEER = 9.7 SEER = -1 Frame,2"x 6' R-19 Common,Frame R-11 Room unit or PTAC EER = 8.5" EER = Common,Masonry R-3 Electric Resistance ANY Z Under Attic R-30 -3b Heat pump-Split HSPF = 6.8 HSPF Single Assembly;enclosed R-19 Single Pkg. HSPF = 6.6 HSPF = v Single Assembly;Opened R-10 x Room unit or PTHP COP = 2.7' HSPF/ Common,Frame R-11 cwi COP rn Slab-on-grade No Minimum a ¢ N Gas,natural or propane AFUE = .78 AFUE Raised Wood R-19 Fuel Oil AFUE = 78 AFUE _ O Raised Concrete R-7 LL Common,Frame R-11 o ffiElectric Resistance EF = .86 EF jIn unconditioned space R-6 _ Gas; Natural or L.P. EF = .54 EF = p In conditioned space No minimum Fuel Oil EF = .54 EF = See Table 6.3,6-7 d + d TABLE 6C-2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY Maximum percentage lass to floor area allowed is selected by type,overhang length,and shading coefficient. Maximum%= Installed% GLASS TYPE,OVERHANG,AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED UP To 20°10 UP TO 30% UP TO 40% UP TO 50% Single Double Single Double Single Double Single Double OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC 1'-1.0 0'-.90 2' 1.0 1'-.90 3'-1.0 2'-.90 4'-1.0 3'-.90 0'-.86 1'-.86 0'-.70 2'-.86 l'-.70 3'-.86 2'-.70 0'-.65 1'-.65 O'_.50 2'-.65 1'-.50 0'-.45 V-45.45 0 .40 0'-.35 Shading coefficients(SC)may be obtained from the manufacturer. Single clear SC=1.0,double clear SC=.97,and single.tint SC=.86. TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES COMPONENTS SECTION REQUIREMENTS CHECK Exterior Joints&Cracks 606.1 To be caulked,gasketed,weather-stripped or otherwise sealed. Interior Joints&Cracks 606.1 All openings in interior surfaces of ceilings and exterior walls must be sealed. Sole&Top Plates Sole plates and penetrations through top plates of exterior was must be sealed. Infiltration Barrier 606.1 Infiltration barrier must be installed in exterior walls&raised wood floors. Fireplaces 606.1 Fireplaces must have flue dampers,glass doors and outside combustion air intakes. Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers,except for combustion devices with integral exhaust ductwork. Combustion 606.1 Combustion space and water heating systems must be provided with outside combustion air, Heating except for direct vent appliances. Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker(electric) or cutoff(gas)must be provided. External or built-in heat trap required. Swimming 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a Pools&Spas pump timer.Gas spa&pool heaters must have minimum thermal efficiency of 78%. Hot Water Pipes 612.1 Insulation is required for hot water circulating systems,(including heat recovery units)and the first 8'of piping from the water heater(or until piping enters an insulated wall or slab). Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. HVAC Duct 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached, Construction, sealed,insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be Insulation&Installation insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closets. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. GENERAL DIRECTIONS: 1. On Table 6C-1 indicate the R-value of the insulation being added to each component and the efficiency levels of the equipment being installed.All R-values and efficiencies installed must meet or exceed the minimum values listed. Components and equipment neither being added nor renovated may be left blank. 2. ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the addition as follows. Total the areas of all glass windows,sliding glass doors and glass door panels. Double the area of all non- vertical roof glass and add it to the previous total.When glass in existing exterior walls is being removed or enclosed by the addition,an amount equal to the total area of this glass may be subtracted from the total glass area. Divide the adjusted glass area total by the conditioned floor area of the addition.Multiply by 100 to get the percent. Find the largest glass percentage under which your calculated percentage falls on Table SC-2.Prescriptives are given by the type of glass(Single or Double pane)and the overhang(OH)paired with a shading coefficient(SC). For a given glass We and overhang,the minimum shading coefficient allowed is specified.Achmi glass windows and doors previously in the exterior walls of the house and being reinstalled in the addition,do not have to comply with the overhang and shading coefficient requirements on Table 6C-2.All new glass in the addition must meet the requirement for one of the options in the glass percentage category you indicated.The overhang(OH)distance is measured perpendicularly from the face of the glass to a point directly under the outermost a* of the overhang. 3. RENOVATIONS ONLY. Replacement glass needs to meet the following requirements. Any glass type and shading coefficient may be used for glass areas which are under at least a two foot overhang and whose lowest edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single-pane tinted,double-pane dear or double-pane tinted. 4. Complete the information requested on the top half of page 1. 5. Read"Minimum Requirements for Small Additions and Renovations",Table 6C-3,and check all applicable items. 6. Read,sign and date the"Owner/Agent"certification statement on page 1. -2- b � { i> € { �} 4 M iL .41 WOW �t .4—HP w fit lox at subAt r0 > x 4 .r," '.7Ni'is apt M'nw a+Y;.r.a+trwa,w 0. dress 4ILLS t? 77, # , ' x top z7 . s 01 Mot fltiw, I� k 5 i -5FjTHeR yy { {4 Tj "s^ z � � pit 7,7 t„AVU mom 1 i y z= 2 :, 1995 Building and Zoning CITY OF ATLANTIC BEACH PMNIT APPLICATION REMODEL, ADDITIONS OR ALTERATIONS DEMOLITION owner(s) : r/'�/ �,L/A ��1�•4� � Address: eOkftone: 2 Y -7 - 3L 11 Lot N Block or Unit N� Subdivision �& U/5C� PJ'4 0� Contractor: 1114 Describe work to be done: lie 4L. .,t, A J tle!T vo Present use of building: 2 / 00Of Proposed use: Is this an addition? If yes, what are the dimensions of the added space: �3 , ft. % J ft. Will the added area be heated and cooled? New electrical (or increase)? New plumbing fixtures? New fireplace?_A/c) New Heat/AC?&_ SUBMIT—Jk COMPLETE SETS OF PLANS, INCLUDING SITE PLAN AND SURVEY IF THERE WILL BE AN ADDITION T P EXIS'T'ING STRUCTUR . Signature OWNER: Date: Signature CONTRACTO ate: l= ' JAMES H My Co n CC3056t3 Expeos Aug.04,1997 OF FL04P CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address ,q U0 . SC /BOOM Date / - 2 9- Heated Square Footage I�e$_per sq ft = $ / Garag a Shed @ $ per sq ft = $ �1rr Carport/Porch V � @ $ per sq ft = $ Deck �r@ $ per sq ft = $ � o Patio @ $ per sq ft = $ TOTAL VALUATION : S1��' l . $ As < Total. Valuation 1st $. l no Remaining Value $5.- per thousand or portion thereof TOTAL BUILDING FEE $ + 1/2 Filing Fee $ / V ( ) Fireplaces @ $15 .00 $ C'J BUILDING PERMIT FEE $—_ WATER IMPACT FEE $ _. SEWER IMPACT FEE $ WATER METER/TAP S _ CAPITAL IMPROVEMENT S SEWER TAP $ _ ( ) RADON (HRS) . 0050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ( ) SURCHARGE . 0050 $ OTHER S GRAND TOTAL DUE ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey ; Other CALCULATIONS and/or NOTES: r September 24, 1995 To Whom It May Concern, I x Larry and,Michelle Walshaw, residing at 90 Ocean Breeze Drive, Atlantic Beach, a residential community known as Ocean Breeze, have the approval of the Ocean Breeze association and its members, to build a screened:patio for the health and safety of their one(1)year old son, Darren. - Sincerely, Kirk Hansen �re 2 7 1995 Building and Zoning 09/13/14, 07:49 'a2 135/06,"z!4 11:Y5 T F ►"F isw CO. .� ? t ��. lb001 MAP SHOWING BOUNDARY SURVEY OF LOT II, �EVISED PLAT OF OCEAN BREEZE:, A$ RECORDED iN PLAT BOOK 46; f'AGES 51 AND 5IA, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIMIM T0: LARRY C WAL*%W AND MICHELE 0. wALSHAW, 00MMO AKAt.Tt1 LAW ME IA SMAWK CO. SUNSAW r NORTH MWIDA,A NATIONAL A"001AT10N, LOT I OCEAN BREEZE DRIVE of p. N890-431"U5"T 60.04' utoo � t Ai11VA7P ROAD) 20,tµtwrt•gat rocs a two ,PUMA AND unmtt ►w-. rAW44 acw.' w ,A lir tir A" C7 1 xtroal ► tro.T► d Iu OJL 4 `�. x 1 aS Q O LOT to xiw�1 ►�� $ APPROVED 0 A LA M C BEACH x 1� BUILDING OFFICE OCT 1995 w w -1I`N le`O C�lc` r7 jiM \xr • tee• x � `' 1995 ` i.` d �. g xJ?s1 r � d x ►��.__ .a9•-43,35"V+' !o,�.. t ildin an Zoritn s. r DOOM s�o RPE 2}�d i�v�nPs�o be.'TRc� S'EA.�CIrn�, ,_yv / F 1 q4 If z , - ��� e S�oc WAN R 11 Str.� W-A I A11sceee _ fZo_ +A< 111 DO�IvICIA 4 Headea- 2h2oss S f u -- --- f, ;. 2X2, Z'KL �c4t 104`{ i 1 � l R_§rA- ouLe ------ GLASS ROOMS: SOLI® WALLS AND COVER TABLE 3: MAXIMUM HEIGHT OF UPRIGHTS FOR SCREEN AND GLASS ROOMS EXTRUSTIONS AND SELF MATING BEAMS OF 6063 T-6 ALUMINUM ALLOY USING SCREEN PANEL WIDTH "W" (SEE TYPICAL GLASS ROOM DRAWING), SELECT UPRIGHT REQUIRED FROM THE MAX HEIGHT ALLOWED FOR EACH EXTRUSION WIDTH "W" 36" 42" 48 54" 60" 66" 72" 78" EXTRUSION 2"x 2"x 0.044" 9'- 2„ 8'- 6" 7'-11" 7'- 6" 7'- 1" 6'- 9" 2"x 2"x 0.050" 10'- 2" 9'- 5" 8'-10" 8'- 2" 7'-11" 7'- 6" 7'- 2" 6'-11" 2"x 2"x 0.093" 12'-10 11'-11" 11'- 1" 10'- 6" 9'-11" 9'- 6" 9'- 1" 8'- 8" 3"x 2"x 0.050" 10'- 8" 9'-11" 9'- 3" 8'- 9" 8'- 3" 7'-11" 7'- 6" 7'- 3" 2"x 3"x 0.050" 12'-10" 11'-11" 11'- 1" 10'- 6" 9'-11" 9'- 6" 9'- 1" 8'- 8" 3"x 2"x 0.070" 13'- 8" 12'- 8" 11'-10" 11'- 2" 10'- 6" 10'- 1" 9'- 8" 9'- 3" NOTES: GLASS ROOMS THE ADDITION OF AN ALUMINUM FRAME WINDOWS W/ GLASS PANES THAT ARE DESIGNED TO 110 MPH WIND LOAD REQUIREMENTS TO THE ABOVE UPRIGHT SIZES INCREASES THE STRENGTH SO THAT ADDITIONAL FRAMING IS NOT REQUIRED. ( d�c�r���o �o C3ol�wo��fl QoCo CIVIL ENGINEER AND DEVELOPMENT CONSULTANT P.O. BOX 4369 S. DAYTONA, FLORIDA 32121-4368 PHONE: (904) 767-4774 PAX: (904) 767-6556 © COPYRIGHT, 1995 NOT TO BE. REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN SECTION: PERMISSION FROM LAWRENCE-E. BENNETT, P.E. PAGE: -83- SCREENED ENCLOSURES: SCREEN / VML WALLS AND SOLD D COVER TABLE 1: MAXIMUM SPANS FOR STANDARD ALUMINUM ROOF PANELS OF 3105 H-14 OR H-25 ALLOY WIND LOADS: CARPORTS, SCREEN ROOMS, AND OTHER OPEN BUILDINGS O.H. CONDITION NO 0. H. 1' 0. H. 2' 0. H. 3' 0. H. 1-1/4"x_0.026" 100 MPH W. L. 7'- 2" 7'- 5" 8'- 2" --- 110 MPH W. L. 6'- 5" 6'- 8" 7'- 6" --- 120 MPH W. L. 5'-10" 6'- 2" 7'- 1" --- 1-1/4"x_0.032" 100 MPH W. L. 8'- 5" 8'- 8" 9'- 3" --- 110 MPH W. L. 7'- 6" 7'- 9" 8'- 6" --- 120 MPH W. L. 6'-10" 7'- 1" 7'-11" --- 1-3/4"x-0.026" 100 MPH W. L. 7'- 5" 7'- 7" 8'- 5" --- 110 MPH W. L. 6'- 8" 6'-11" 7'- 9" --- 120 MPH W. L. 6'- 1" 6'- 4" 7'- 3" --- 1-3/4"x_0.032" 100 MPH W. L. 8'- 9" 9'- O" 9'- 7" --- 110 MPH W. L. 7'-10" 8'- 1" 8'- 9" --- 120 MPH W. L. 7'- 1" 7'- 5" 8'- 2" --- 3"x_0.026" 100 MPH W. L. 13'- 1" 13'- 3" 13'- 8" 14'- 5" 110 MPH W. L. 11'- 9" 11'-11 12'- 5" 13'- 2" 120 MPH W. L. 10'- 8" 10'-11" 11'- 5" 12'- 3" 3"x_0.032" 100 MPH W. L. 15'- 6" 15'- 8" 16'- 0" 16'- 7" 110 MPH W. L. 13'-10" 14'- 0" 14'- 5" 15'- 1" 120 MPH W. L. 12'- 8" 12'-10" 13'- 3" 14'- 4" LIVE LOAD; ALL BUILDING TYPES O.H. CONDITION NO 0. H. 1' 0. H. 2' 0. H. 3' 0. H. 1-1/4"x_0.026" 20 #/SF L. L. 7'- 0" 7'- 3" 8'- 1" --- 30 #/SF L. L. 5'- 9" 6'- 1" 7'- 0" --- 1-1/4"x_0.032" 20 #/SF L. L. 8'- 3" 8'- '6„ 9'- 2" --- 30 #/SF L. L. 6'- 9" 7'- 0" 7'-10" --- 1-3/4"x-0.026" 20 #/SF L. L. 7'- 4" 7'- 7" 8'- 4" --- 30 #/SF L. L. 6'- 0" 6'- 4" 7'-11" --- 1-3/4"x-0.032" 20 #/SF L. L. 8'- 7" 8'-10" 9'- 6" --- 30 #/SF L. L. 7'- 0" 7'- 4" 8'- 1" --- 3"x_0.026" 20 #/SF L. L. 13'- 3" 13'- 4" 13'-10" 14'- 6" 30 #/SF L. L. 10'- 9" 11'- 0" 11'- 6" 12' 4" 3"x_0.032" 20 #/SF L. L. 15'- 1" 15'- 2" 15'- 7" 16'- 2" 30 #/SF L. L. 12'- 3" 12'- 5" 12'-11 13'- 8" 1. TOTAL ROOF PANEL WIDTH = ROOM WIDTH PLUS WALL WIDTH PLUS OVERHANG. 2. THE SMALLEST VALUE OF THE WIND LOAD TABLE OR THE L.L. TABLE GOVERNS. d�c�rro�c�o Leo C3on�o��9 poCa CIVIL ENGINEER AND DEVELOPMENT CONSULTANT P.O. BOX 4369 S. DAYTONA, FLORIDA 32121-4368 PHONE: (904) 767-4774 FAX: (904) 767-6556 SECTION: © COP`RIGHT, 1995 \JT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN =ERMISSION FROM LAWRENCE E. BEPlPIETT, P.E. PAGE: f' - ]2 -30- SCREENED ENCLOSURES: SCREEN / VINYL WALLS AND SOFT® COVER 2"x 6"x 0.050"x 0.120" S.M.B. --------------------------------------- 5' 17'- 2" 14'- 0" 19'- 2" 17'- 2" 15'- 8" t 6' 15'- 8" 12'- 9" 17'- 6" 15'- 8" 14'- 3" 7' 14'- 6" 11'-10" 16'- 2" 14'- 6" 13'- 3" 8' 13'- 7" 11'- 1" 15'- 2" 13'- 7" 12'- 4" 9' 12'- 9" 10'- 5" 14'- 3" 12'- 9" 11'- 8" 10' 12'- 1" 9'-11" 13'- 7" 12'- 1" 11'- 1" 11' 11'- 1" 9'- 5" 12'-11 11'- 7" 10'- 6" 12' 10'- 3" 9'- 0" 12'- 4" 10'- 3" 10'- 1" 2"x 7"x 0.062"x 0.120" S.M.B. --------------------------------------- 6' 17'- 9" 14'- 6" 19'-11" 17'- 9" 16'- 3" 7' 16'- 6" 13'- 5" 18'- 5" 16'- 6" 15'- 0" 8' 15'- 5" 12'- 7" 17'- 3" 15'- 5" 14'- 1" 9' 14'- 6" 11'-10" 16'- 3" 14'- 6" 13'- 3" 10' 13'- 9" 11'- 3" 15'- 5" 13'- 9" 12'- 9" 11' 13'- 1" 10'- 9" 14'- 8" 13'- 1" 12'- 0" 12' 12'- 7" 10'- 3" 14'- 1" 12'- 7" 11'- 6" 13' 12'- 1" 9'-10" 13'- 6" 12'- 1" 11'- 0" 14' 111- 8" 9'- 6" 13'- 0" 11'- 8" 10'- 7" 2"x 7"x 0.062"x 0.135" S.M.B. --------------------------------------- 6' 18'- 4" 15'- 0" 20'- 6" 18'- 4" 16'- 9" 7' 17'- 0" 13'-11" 19'- 0" 17'- 0" 15'- 6" 8' 15'-11" 13'- 0" 17'- 9" 15-11" 14'- 6" 9' 15'- 0" 12'- 3" 16'- 9" 15'- 0" 13'- 8" 10' 14'-10 11'- 7" 15'-11 14'- 3" 13'- 0" 11' 13'- 7" 11'- 1" 15'- 2" 13'- 7" 12'- 4" 12' 13'- 0" 10'- 7" 14'- 6" 13'- 0" 11'-10" 13' 12'- 6" 10'- 2" 13'-11" 12'- 6" 11'- 5" 14' 11'- 7" 9'-10" 13'- 5" 11'- 7" 10'-11" 2"x 8"x 0.072"x 0.224" S.M.B. --------------------------------------- f 7' 21'- 9" 17'- 9" 24'- 4" 21'- 9" 19'-11" 4 8' 20'- 4" 16'- 7" 22'- 9" 20'- 4" 18'- 7" 9' 19'- 2" 15'- 8" 21'- 6" 19'- 2" 17'- 6" 10' 18'- 2" 14'-10' 20'- 4" 18'- 2" 16'- 7" 11' 17'- 4" 14'- 2" 19'- 5" 17'- 4" 15'-10" 12' 16'- 7" 13'- 7" 18'- 7" 16'- 7" 15'- 2" 13' 16'- 0" 13'- 0" 17'-10" 16'- 0" 14'- 7" 14' 15'- 5" 12'- 7" 17'- 2" 15'- 5" 14'- 0" 2"x 9"x 0.072"x 0.224" S.M.B. --------------------------------------- 7' 24'- 2" 19'- 9" 27'- 0" 24'- 2" 22'- 1" 8' 22'- 7" 18'- 6" 25'- 3" 22'- 7" 20'- 8" 9' 21'- 4" 17'- 5" 23'-10" 21'- 4" 19'- 6" 10' 20'- 3" 16'- 6" 22'- 7" 20'- 3" 18'- 6" 11' 19'- 3" 15'- 9" 21'- 6" 19'- 3" 17'- 7" 12' 18'- 5" 15'- 1" 20'- 8" 18'- 5" 16'-10" 13' 17'- 9" 14'- 6" 19'-10" 17'- 9" 16'- 2" 14' 17'- 1" 13'-11" 19'- 1" 17'- 1" 15'- 7" 2"x 9"x 0.072"x 0.310" S.M.B. --------------------------------------- 7' 26'-11" 21'-11" 30'- 1" 26'-11" 24'- 7" 8' 25'- 2" 20 - 6 28 - 2 25 - 2 22'-11 9' 23'- 9" 19'- 4" 26'- 6" 23'- 9" 21'- 8" 10' 22'- 6" 18'- 4" 25'- 2" 22'- 6" 20'- 6" 11' 21'- 5" 17'- 6" 24'- 0" 21'- 5" 19'- 7" 12' 20'- 6" 16'- 9" 22'-11 20'- 6" 18'- 9" 13' 19'- 9" 16'- 1" 22'- 1" 19'- 9" 18'- 0" 14' 191- 0 15'- 6" 21'- 3" 19'- 0" 17'- 4" i d��r�onc�o Go C3or��o�t�v polio CIVIL ENGINEER AND DEVELOPMENT CONSULTANT P.O. BOX 4369 S. DAYTONA, FLORIDA 32'.21-4368 PHONE: (904) 767-4774 FAX: (904) 767-6556 SECTION: �� COPYRIGHT, 1995 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT WP -TEN PERMISSION FROM LAWRENCE E. BENNETT, P.E. PAGE: 10-12 -33- GLASS ROOMS: SOLID WALLS AND COMER TABLE 2: MAX. ROOF BEAM SPANS FOR SCREEN & GLASS ROOMS, UTILITY ROOMS, SHEDS AND OTHER ENCLOSED STRUCTURES W/ SOLID ROOFS ALUMINUM BEAMS OF 6063 T-6 ALLOY EXAMPLE: FOR SPAN "L" ON DRAWING USE LOAD WIDTH = "W"/2 + O.H. 2"x 4"x 0.050" TILT BEAM: LOAD WIDTH = 14'/2 + 2'O.H. = 9' LOAD WITH = 9'; L.L. @ 22#/SF BEAM SPAN = 4'- 4" BEAM SIZE BEAM SPAN FOR DESIGNATED LOADS BEAM LIVE LOADWIND LOAD LOAD WIDTH 22#/SF 32#/SF 100 MPH 110 MPH 120 MPH 2"x 2"x0.044" EXTRUSION 5' 5'-10" 4'- 9" 4'-10" 4'- 5" 4'- 1" 6' 5'- 4" 4'- 4" 4'- 5" 4'- 0" 3'- 9" 74'-11" 4'- 0" 4'- 1" 3'- 9" 3'- 5" 8' 4'- 7" 3'- 9" 3'-10" 3'- 6" 3'- 2" 9' 4'- 4" 3'- 6" 3'- 7" 3'- 3" 3'- 0" 10' 4'- 1" 3'- 4" 3'- 5" 3'- 1" 2'-10" 11' 3'-11" 3'- 2" 3'- 3" 2'-11" 2'- 9" 2"x 2"x 0.050" EXTRUSION 5' 6'- 1" 5'- 0" 5'- 1" 4'- 7" 4'- 3" 6' 5'- 7" 4'- 6" 4'- 7" 4'- 2" 3'-11" 7' 5'- 2" 4'- 2" 4'- 3" 3'-11" 3'- 7" 8' 4'-10" 3'-11" 4'- 0" 3'- 7" 3'- 4 9' EXAMPLE 4'- 6" 3'- 8" 3'- 9" 3'- 5" 3'- 2" 10' 4'- 4" 3'- 6" 3'- 7" 3'- 3" 3'- 0" 11' 4'- 1" 3'- 4" 3'- 5" 3'- 1" 2'-10" 4. 2"x 2"x 0.093 EXT OR 2"x 3"x0.050" TILT BEAM OR 2"x 3"x0.050" EXTRUSION 5' 8'- 0" 6'- 6" 6'- 8" 6'- 0" 5'- 7" 6' 7'- 4" 5'-11" 6'- 1" 5'- 6" 5'- 1" 7' 6'- 9" 5'- 6" 5'- 7" 5'- 1" 4'- 8" 8' 6'- 4" 5'- 2" 5'- 3" 4'- 9" 4'- 5" 9' 5'-11" 4'-10" 4'-11" - 4'- 6" 4' 1" 10' 5'- 8" 4'- 7" 4'- 8" 4'- 3" 3'-11" 11' 5'- 5" 4'- 4" 4'- 5" 4'- 0" 3'-1 D" 3"x 2"x 0.050" EXTRUSION 5' 7'- 5" 6'- 1" 6'- 2" 5'- 7" 5'- 2" 6' 6'- 9" 5'- 6 5'- 7" 5'- 1" 4,- 9„ 7' 6'- 3" 5'- 1" 5'- 2" 4'- 9„ 4,- 4„ 8' 5'-10" 4'- 9" 4'-10" 4'- 5" 4'- 1" 9' 5'- 6" 4'- 6" 4'- 7" 4'- 2" 3'-10" 10' 5'- 3" 4'- 3" 4'- 4" 3'-11" 31- 8" 11' 5'- 0" 4'- 1" 4'- 2" 3'- 9" 3'- 6" d�c�r�o�c�o G4 C3ol�wo�t�fl poC�o CIVIL ENGINEER AND DEVELOPMENT CONSULTANT P.O. BOX 4369 S. DAYTONA, FLORIDA 32121-4368 PHONE: (904) 767-4774 FAX: (904) 767-6556 L� COPYRIGHT, 1995 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT WPiTTEN SECTION: PERMISSION FROM LAWRENCE E. BENNETT, P.E. PAGE: -81 - v, - a Pr-Kmt CITY OF ATLANTIC BREACH PERMIT CALCULATION SHEET Address 5,6 Q tyh., fJK. r��Z � � g Date Heated Sauare Footage -7@ $ S ° �d per sq ft Garage/Shed @ $ per sq ft = S Carport/Porch @ $ per sq ft = S Deck @ $ 5 per sq ft = $ Patio @ $ per sq ft = $ TOTAL VALUATION: S rlc, (� 0 / f rf E� $ 1 ,S—, 0c Total Valuation 1st $ ° Remaining Value $s-."Oiler thousand or portion thereof TOTAL BUILDING FEE $ + 1/2 Filing Fee $ /,&rD U ( ) Fireplaces @ $15 . 00 $ _ BUILDING PERMIT FEE $___ WATER IMPACT FEE $__ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT $ _ SEWER TAP $ ( ) RADON (HRS) .0050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ( ) SURCHARGE .0050 $ OTHER $ GRAND TOTAL DUE $ ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES: MAP'­SHdWING BOUNDARY SURVEY OF LOT 11, REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. conlFfm TO: LARRY E.WALSN0 AND MICHELE D. WALSHAW. COAMIONllMEAum LAND TITLE INSURANCE CO. SUFNk%W f NORTH FLORIDA.A NATIONAL. ASSOCIATION, LOT I OCEAN BREEZE DRIVE k% y fv t40z FO tom°cAP (PRIVATE ROAD) N890-43'-35"E 60.00' W EAMMEW FM V OBEs•EORESS DPANA E AM tmI rnEs L7 FAVM PIPE Ctptti AND 6U1^rER - cr 7 JEA ` Q / I$'P CODK�IETE OWE.i, ia Q / for, 24 0 90 O �( VK 0 $ 0 OQ (:gip•-" d ? 3. 0 r LOT 10 4Ar ox >r O 1b `. 4d' V F M O �,� 8 0.4 10'' p 8 'a 2-STORY Snxxo REEIDB"NO.to W IoAK 0� N io CV WE © +e 4$' FiN.FLOOR 0 z � �• EL.12.1 N.G.V.D. N w� of ao. ( lar Ia4• 7.s tr i�2" FfL DECK N p7 OAK !4'BA'L z p, + 73 T"agc 12"0Alt 0 00 t2' oa q a 2 x; 1995or u FID.TACK 04 �'OAK 0 Cb e•aAK �► 6Q.001 i,ng and Zoning or s,u= S89°-43'-35"W 00 rant """ mot � Ma,� 541- sir ARE FROM RFVOD 124.04 TOO MOW Ftp AL MTV') s-a�4 wmv ,ss TO Saw rn MA-nwjo . P STONE,JOCA i October 9, 1997 01 MAHONEY Consulting Engineers,Inc. Mr. Don Ford Chief Building Inspector City of Atlantic Beach Atlantic Beach, FL RE: Mr. and Mrs. Larry Walshaw Lot 11, Ocean Breeze Dr., Atlantic Beach Wind Load Analysis for 10x 13 Addition SJM #1545 Dear Mr. Ford: We have reviewed the plans for the above-referenced project and found the plans are meeting the Southern Building Code-SSTD-10-93 Section 1606 for wind loads. Please see the original calculations for footing design, overturning movement, uplift forces, and the exterior wall design. Attached are revised Hughes Tie-Down Nomenclature as found in the 97/98 product catalog. If you have any questions, please call me at 904/264-1377. Sincerely, APPROVED CITY .Of .ATLANTIC BEACH ONE, J CA & MAHONEY, INC. BUILDING OFFIC5 .�.� OCT 14 1997 to/1 /97 John J. Mahoney, P.E. Vice President JJM/gp RECEIVED Attachments f)O'T 1 1997 City of Atlantic Beach Building and Zoning Foxwood Center • Suite D • 1730 Kingsley Avenue - Orange Park, Florida 32073 • (904) 264-1377 • Fax (904) 278-8469 7400 Baymeadows Way • Suite 106 • Jacksonville, Florida 32256 (904) 448-5300 • Fax (904) 448-0401 a -------------------------___________, _._------------------------- ENGINERED TRUSSES-GABLE 4D 4-0X4-4 R-30 CEILING INSULATION SEE CUT SECTION FOR EXISTING ROOF BINE; a 3-0X4-4 TYPICAL ORIGINAL DECK PLAN ,3n -' EXISTING SHED ROOF ---------------- EXISTING ROOF BEDROOM; ADDITION i WALSHAW RESIDENCE j SCALE 114=1 FT. STRESSWALL PANEL NOTES: 112 OSB NAILED 4"O.C.EDGE NEW WALL 6"IN FIELD 2)(6-16- HUGHES WAM ANCHORED TO O.C. LINTEL WITH 6"X 5/6"RED PLACE ON EXISTING ROOF ,t "3S rtij HEAD-UL#46WLBS 27 INCH DECK-CUT BACK ROOFING ^i E -H i. Ek.. RNER AND 4 FT. FOR TIE DOWNS AND RE-SEAL 24 EACH 9 MM NAILS R-19 INSULATION HUGHES TP6X EACH STUD WALLS AND ENTIRE WALL UL#1465 FLOOR 10 EACH 9 MM NAILS VAPOR SHIELD N L-STA 24 STUCCO TO MATCH HUGHES$P 24 JOIST TO EXISTING TA 16 STUD STRAP UL0MR. 12 foo lbs, EACH JOIST MATCH EXISTING EAVE 32"O.C. itS EACH 9 Fes\ DETAIL IMBED ANCHOR MM NAILS AD HURRICANE ANCHORS HCDPL SEE NOTES FOR EACH STUD UL #495 EACH TRUSS 1 lI i t rrAl81T1.SEt/Fted Head RED HEAD TRUBOLTWFi� CONCRETEANCHOR/N6SMEWS OfPENDABLE, HA DUTY INSPECTABLE,WEDGE TypE EXPANSION ANCHOR SELECF►ON CHART 302H� carbo narv.Mae 0aa asawa 10f e otasmar Ma. o 9°" s c saes r staN a orm Tbiaklra MM. Moot- _ to be wag C sh Sire/ A at Mm" embed•IN ra" Ianea Throw Metlar Leap Ne lb�glk N�eailit Leap NeThrow Thl"do i LOO Pe buk � FaWN Ctmaam ( .1 77-- li WS-1416' 3/4" WW-1416• 3/4" SWW-1416 3/4" t-3/4" 3/8" - W&1422 1.1/4" WW4422' 1�1/4" SWW-1422 3/4" 1/4'120 2.1/4" 7/8" 1.118- 8 WS7432' 2-1/4" WW-1432' 21/4" 34/4" 1-7/8" b 4-WS3822' 1-1/8" awW-3822' td/8" 21/4" 3/8" 445-3826• t-5/8" 4•WW-3826' 1.5/8" 4-SWW-3826 )418" 23/4" 7/8" I 4•WS3930' t-7/B" W1 3830* 1.7/8" 4•Sw*3830 114/8" 3/8"716 3" 1 1/8" 1-1:2' 25 a 1 ••WS3836' 25/8" s•WW-3836' 25/8' 4•SWW-3836 14/8" 3.314" 17/8" 4aWS3850' 2-112" awW-3850• 2112' S" 8178" +o 4•WSt226' 14/4" 4•wS-1226G' 14/4" t-lit t226• t-v4" 4•SWW122fi 1.5/16" 23/4" 1/8" ! ••WSt236' Z-V4" 4•WW-1236' 21/4" aSWW-1236 115/116" 3374" t" aWSt242• 2314^ 4•wSt242G' 2314" *,WW-242' 23/4" 4•SWW4242 15716" v2"n3 a-t/4^ t-112" 21 a" 55 4•WS1254' 3" 4•W5•;254G' 3" 4•WW-1254' 3" 4•S"-1254 115/116" 5.1/2" 23/4" 4•WS1270' 4.1/2" 4•WS1270G' 4.1/2" 44w-1270' 4.112" 7" 4.1/4" rwS5834 13114" 4•WS5834G• t-3/4" 4•WW-5934' 1.3/4" &v2" 8" 4•WS5842' 24/2" 1 4.1/4" 7/8" ♦•wS5850' 3.1/4" ♦•WW-5850' 34/4" at•SWW-5850 1-3/4" 5" _ ••WS-5860' 3-v2" e•WS58600860 ' 3.1/2" +:WW-5 ' 34/2" 5/8"1t1 6" 25/8" 2-34" 90 p aWS5870' 4.1/2" 4WW-5810' 4.1/2" 7" 3-5/8" -. aWS 884 3/4" 4•WW5684 13/4" 4•SWW-5884 1.3/4" 8.1,2" 91,8" 4•wS58100 1.3/4" 0" 6.5/8" :-WS3442' 1-3/4" •W8_3446' 2.1/4" rWS3446G' 2IA" e-W3446* 21/4" #-SWW-3446 1.3/4" 4.3/4" 3/4' _ 4•WS3454' 3" ♦•WS3454G' 3' a-4*3454' 3" ••SWW3454 1-3/4" 5412' 1-12" 4-WS-W2' 3-3/4" 64/4" 2-1,4" aWS•3470' 4.1/2" 4•WW3470• 4112" 3A 10 1' 3' 31 4" 175 A ♦•W5,341.3/4" 4•WS-348aG 3/4" :WW 33484 4" &I 2" 4-L Z" I 4•WS341010 0 1-3/4" 4•WW.34100 -3/4" U" 6" Irr.444 4•WS34120 113/4" WS-7860 2412" WS-78M 2.112" WW-78W 2-1/2" 7/8'198" 33/9" 3.3'4- 250 k - WS78100 21/2" 10" 53/8" rwS10060 2�112" ww IDWO 21/2" 6" 1,2"tWS10090 2.1112" tWS1009M 2412" WW4090 02.1/2" v/8 9" 311/2' 41,24 300 TIE-WIRE tWS-t00120 2-I11z' 2" 61,2' VERSION . 1 ? 1WS12590 3.1/2" 9" 21.4" 12 �. twS)25;20 3112" 1'1'4"rT " 5-ba' 512' ' Tie Wire # TWS4400 I N/AJ. I/4" 23/76" Eye Dia. t t 8" NrA " 'Fully Threaaea d t PERFORMANCE CHARTS Stainless Stew II Car9at Stew ANCHOR MATERIALS �1 4000P81' 4MMS1 Carbon Steel Stainless Steel of mar � shox' Embea- uahbale Onimate Bolt Body: AISI 1015-1022,C1213/15 Boit Body: Type 302HQ,303,Type Anchor mem sit Isdoat' Shou' Expansion Clip; Type 302 S.S.,AISI 1010 Expansion Cli Type 302 sin calelw Las. Lae P YP P YP /8" 1559 1828 See Coacrote Lbr, LOS. Washer: AI51-01010-1020 Waa sher: Type 18-8,Type 316 1114" 145116" 2999 1910 1-118" 1869 2354 Nut: Low carbon steel; Nut: Type 18$Type 316 " 23/4" M51 1991 1/4" t-15/16" 3084 2375 ASTM A 563 Grade A 14/21' 3219 46i 23/4" 3102 2395 3/8" 3" 5678 4305 1112" 3145 4338 SPECIFICATIONS 442"4 $935 4581 3/6" 3" 5661 5012 Carbon Steel Stainless Steel D 24/45384 6900 4412" 6396 5686 4.1/88.8 " 1333 7449 2 t/4" 6032 9542 ASTM A 101,ASTM A 510 ASTM A 276,ASTM A 479 6" 9003 7998 1/2" 44/8" 8593 9773 FF-5-325 Group 11, Type 4,Class 1 ASTM A 581,ASTM.a 582 9974 10003 ASTM B 633.85,SCI,Type III QQ-S763D,QQ-S-7645 58" St78" t 2314" 7646 13339 ASTM A 153,Class C AMS 5648E,AMS 1,�M,Type j - 1 zqw WEI" 5.1/8" 11897 14227 For Hot-Dip Galy. MIL-W-52263C F 3.1/4" 9921 18128 7.1/2" 12791 15115 FF-S-325 Group II, Type 4,Clam 3/4" 6.5/8" 16489 18585 3�v4" ;0069 18773 10" 19953 19042 314" 6.3/9" 16027 21795 1 33/4" 1367225122 9" 16839 24153 7/8" 6•;14" 20029 25122 33/4" 15295 25198 8.3114" 20707 25122 718" 6-V4" 18687 28826 4-1/2" 20871 2843) &3/4" 253U 30018 CENTER TO CENTER SPACING A I 1" 73/8" 30610 29763 4-1,2" 18998 33409 AND EDGE DISTANCE 10-1/4" 37820 31094 I" 7.3/8" 20764 36260 I 5.1/2" 27156 44385 10414" 22755 39111 14/4" 8" 53261 46776 *1/2" 60417 48689 b' Tie WRe 1.1/8" 1 1559 1 N/A Ultimate load apacily in 4,000 psi stone aggregate concrete.UffunaM pupauf and shear loads a indicated for Me depth o/embedment in concrete shown in Me"Embedment in Concrete" B column eased on Independent Testing Laboratory tests,ATEC Associates,Inc,Report a'S-3249 A dated 12111/95 Cop-or reports available upon,.quest. Minimum Spacing ,Minimum tW diameter carbon steel archon were tested at s depth of 1042"for tensile capacities and 101 Center to Center Edge DistaneA in,sn"' Anchor 1"diameter stainless steel anchors were tested at a depth of 101/T for tensile capacities and 10114" pia, Hardrock Lightweight Hardrock 1 Por shex e C Safe working loads for single mstap:rions under wane loading should not exceed 25%oI the Concrete Concrete Concrete i ultimate load capaciy.fonnfo mahon on other conditions,c mace You nearest factor.epee- 10 Dia. 12 Dia. rj Dla• sensitive. t Carbon steel anchor sizes through 7,rin domerer have stainless steel expacs clips.Larger diameter canon steel and galvanised anchors have carbon steel expansion dips.All size seam- 1/e" 21/2" 3" i } less steel anchors have stainless s(W expansion dips. For load capaaties in structural hghtweighf aggregare concrete,rete,to 1080 Report b 1372 or 3/e i 33/4" 41/2" 1Ile j contact rechnical 5e,,ce Department 1/2" 5" 611 21/2^ for extreme!caw temperature appficarrons use stainless steer anchors s/e" 61h° 71/2" MOTE.Capacities shown m SOeclion Chan are based on moss recent resting performed in compliance with ASTM E-Me and?CRO Research Committee Standards to,Testing Expansbn 3/4" 71/2 9" 3�a" 7/e" 83/4" 1012" 43.6, 10" 12, 1997/1998 PRODUCT CATALOG Serving the Building Industry for Over 35 Years Better Than Equal ffiUGHESI MANUFACTURING, INC. 11910 62nd Street, North Largo, Florida 33773 CALL TOLL FREE 1-800-443-6442 Fax (813) 535-8199 (813) 536-7891 LOADS BASED ® ON 1991 Visit Our World Wide Web Site and Download Electronic Drawing Files URL http://www.hughesmfg.com FLUG H E MANUFACTURING,INC. Wood To Concrete (S10 WALL ANCHORS • Meets a variety of load specifications • Wall anchors can be used as a substitute for strap anchors • 12 gauge galvanized steel � • Hole pattern is staggered • Minimum 3/4" diameter anchor bolt D (requires embedment analysis) D'DD • 1CB0 Evaluation Report No. 2894 INCORRECT Product Fasteners Design Loads(lbs) Description Length D Code Wall Base Nails Bolts/Wall ---� WAM Heavy Wall Anchor 27-11/16" 24-16d/(4)1/2"MB 3/4"Dia 41qv 3010 WAL 50 1 Wall Anchor 120.1 10-16d 1/2" Dia 1800 2.1/2„ HEAVY HOLD DOWNS HHD2/5A • New Hold Down device with greater load capacity Typical Installation • No washer required, utilizes load transfer plate Typical HHfa • Anchors vertical wood members to foundations to installation resist uplifts due to overturning plate—prov • Anchors may be used to transfer tension loads the same lo �Install between floors the HHD2/SWashers • Galvanized steel for added protection from corrosion installed on plate. • SBCCI PST&ESI 9659 Typical Multi- To get the full load Hold Down capacity stated in the Usage table,the minimum bolt 0 end distance for all hold downs is seven(7) - times the bolt diameter. -" This distance is Threaded automatically designed into HHD2/5A and3 Rod Minimum 7 Dia. HHD8110A hold downs. edge Distance The bolt end distance may be increased as necessary without affecting the load capacity provided that HHD8/10A A the anchor nut is not HHD2/5A Install over-torqued which Typical Tie Washers could split the wood Between framing member. Floors HHD2/5A Product Bolt Schedule Allowable Design Loads(Ibs)(1) N Code Description Heigth Wood Concrete(2) 1-1/2" 3" 3-1/2" 5-1/2" HH02/5A 12 ga Hold downs 9-1/2"" (2)5/8"MB (5/8")X 9" 2067 3536 3536 3536 HHD8/10A 10 ga Hold downs 12-1/2" (3)7/8"MB (7/8")X 14" 3171 8444 9560 9560 (1)Design values associated with wood member thickness,as shown in chart. (2)Anchor'J'bolt or headed MB embedded into concrete/masonry, lengths shown in chart. 43 0 au mo E AS I Wood To Wood HURRICANE CLIPS Z'" • All purpose wind connectors for trusses and rafters • HCLH/RH & HCDPUPR available in stainless steel - add "S" to product code 8,�4 • Dade County Approval No. 95-1023.03 • Dade County Approval No. 97-0421.05 • SBCCI PST & ESI No. 9408A and No. 94139 L1 118' 1.1 Ll 2-1 8„_� HC 20 y L1 5.1/4” L1'� HCS Single Piece 2-1/8" HCDPL/R Double Plate l Right&Left 2-s/8" —{— 3-3/4" 2-1/2" L 1 L�It. �,-sns' � 1.1 5-3/8" L2 HCLH/RH 20 & 18 Ga Right& Left Product Description Material Oty/ wgv Fasteners Design Loads(lbs) Laterial Loads(lbs) a Code Box Box Plates/Stud Truss/Joist Uplift(133°/x)Uplift(1601/6) 1.1(133°/61160%) L2(133%/160%) HCLH I Hurricane Clip-Left Hand 20 ga 100(500 M) 44 4-861 4-861 325 325 200 160 HCRH Hurricane Clip-Right Hand 20 ga 100(500 M) 44 4-8d 4-8d 325 325 200 160 HCLH 18 Hurricane Clip-Left Hand-Heavy 18 ga 100 25 4-861 4-861 360 360 200 200 HCRH 18 Hurricane Clip-Right Hand-Heavy 18 ga 100 25 4-861 4-861 3 0 360 200 200 HCDPL Hurricane Clip-Double Plate Left 20 ga 100 11 4-861 4-861 495 495 255 160 HCDPR I Hurricane Clip.Double Piate Right 20 ga 100 11 4-8d 4-8d 4 5 495 255 160 HCS Hurricane Clip-Single Piece 1 18 ga 1100 1 21 4-8d 4-8d 475 1 475 1 355 1 250 HC 20 Hurricane Clip-Large 1 16 ga 25L+25R 40 1 9-8d 9-861 1 1250 1 1250 1 625 Notes: 1. Allowable loads for Uplift, L1 and L2 shall not be combined. 2. The connectors shall be subjected to loads in one direction only. 3. Design values may be doubled provided all the following criteria is met: a. Maximum of two of the same connectors per location. b. Care should be used in order that nails are not driven in conflict with each other or the connector. c. Straps or clips must not overlap the other connector. 18 ff KrxH:ESj MANUFACTURING,INC. Wood To Wood - ..; STRAP/TENSION TIES y �- ws- ► w �- • Complete range of straps to meet a variety of applications f 3/8• ,.,,4• • Staggered nail spacing to reduce possibility of splitting wood member • 7 ga & 3 ga products painted finish all others galvanized steel ! • Alternate nail schedules upon request • SBCCI PST&ESI No. 9659 -1I••I Wlf- -.►� W -►�+4 3/8" "r -a W l.♦ i•I W If f 3/8' �1/VI-r N �N p rrppmmp m i 2 IANNt/1N yNy Ny ixixx xxxix HST i� HFHA HST HLSTA & All nail holes spaced 1"O.C.Vertically l HMSTA .L �-d L I HHST2&HHST3 W HHST5&HHST6 ---------------------------- 1-1/4" 2-1/4" HHST2&HHST3 1.1/2" � 3" HHSTS&HHST6 r• L J w HMSTf HMST I nj1,j1/4 HPS HPS218&HPS418 1 2.1/2"HPS720-'11I 3-1/4' ./2• Strap/Tension Ties continued on the next page 26 i i- fFI= I Ii MANUFACTURING,INC. Wood To Wood STUD PLATE TIES • Tie studs to the top/bottom plate in II.I:(I1111TI, wind conditions • Nails must be installed into the plate 1I.J:fIl111II: before the stud • 1 - 10d nail must be installed at an angle through the stud into the 5-1/16° plate at square hole locator (PT2=6-5/8") • Easy and fast installation PT2 • Featuring "Hands Free" indent • SBCCI PST & ESI No. 9659 .I PT1 L1 I�U Product Qty/ Fasteners Design Loads(lbs) Laterial Loads(lbs) Code Material Box Stud Plate(s) Uplift(133%) Uplift(160%) L1(133%/160%) L2(133°/a/160% PT 1 20 ga galvanized steel 50 6-10d 4-10d 595 595 480 365 PT 2 20 ga galvanized steel 50 6-10d 16-10d 960 960 560 410 Notes: 1. Allowable loads for Uplift, L1 and L2 shall not be combined. 2. The connectors shall be subjected to loads in one direction only. TOP PLATE ANCHORS 1-1/2" A • Anchor top and bottom plate to studs • Galvanized steel • SBCCI PST & ESI No. 9408A and No. 94139 • Dade County Approval No. 94-0706.09 • Dade County Approval No. 97-0421.05 B I 01 e-_ I o I oaa a 9 a4 as .ala�aa v ooao • ,00 - 0 Product Dimensions pty/ yyg� Design Loads(lbs) Design Loads(lbs) Materials Fasteners Uplift Uplift Fasteners Uplift Uplift Code A g Box Box Stud 133% 160% Stud 133% 160% TP 4X 18 ga 3-5/8" 7-3/16" 100 55 10-10d 1465 1465 10-16d 2155 2155 a--�► TP 6X - 18 ga 5-5/8" 8" 100 55 10-10d 465 1465 10-16d 2155 2155 TP 8X 18 ga 7-3/8" 8-3/16"1100 55 10-10d 1465 1 1465 1 10-16d 2155 1 2155 23 UtIL163HESI MAIMUFACTURING,INC. - Wood To wood STRAP/TENSION TIES Design Loads(Ibs) Design Loads(Ibs) Product Material Code Gauge Dimensions Fasteners Nails Bolts W L Nails Bolts Normal(100%) Uplift(133%)Uplift(160%) Normal(100%) Uplift(133%)Uplift(160%) HLSTA 9 20 1-1/4" 9" 8-10d - 484 644 776 - - - HLSTA 12 20 1-1/4" 12" 10-10d - 605 805 970 - - - HLSTA 15 20 1-1/4" 15" 12-10d - 726 966 1164 - - - HLSTA 18 20 1-1/4" 18" 14-10d 847 1127 1260 - - - HLSTA 21 20 1-1/4" 21" 16-10d - 947 1260 1260 - - - -�` HLSTA 24 20 1-1/4" 24" 16-10d - 947 C 1260 1260 - - - HST 292 20 2" 9-5/16" 8-16d - 484 644 776 1 - - - HST 2122 20 2" 12-13/16" 12-16d - 726 966 1164 - - - HST 2115 20 1" 16-5/16" 10-16d - 605 805 970 - - - HST 2215 20 2" 16-5/16" 16-16d - 908 1208 1552 - - - HLSTA 30 18 1-1/4" 30" 20-10d - 1210 1609 1640 - - - HLSTA 36 18 1-1/4" 36" 22-10d - 1233 1640 1640 - - - HMSTA 9 18 1-1/4" 9" 8-10d - 484 644 776 - - - HMSTA 12 18 1-1/4" 12" 10-10d - 605 805 970 - - - HMSTA 15 18 1-1/4" 15" 12-10d - 726 966 1164 - - - HMSTA 18 18 1-1/4" 18" 14-10d - 847 1127 1358 - - - HMSTA 21 18 1-1/4" 21" 16-10d - 968 1287 1552 - - - HMSTA 24 18 1-1/4" 24" 18-10d - 1089 1448 1640 - - - HMSTA 30 16 1-1/4" 30" 22.10d - 1342 1785 2017 - - - HMSTA 36 16 1-1/4" 36" 26-10d 1516 2017 2017 - - - HST 6215 16 2" 16-5/16" 16-16d - 1168 1553 1872 - - HST 6224 16 2" 23-5/16" 24-16d - 1752 2330 2808 - - HST 9 16 1-1/4" 9" 8-16d - 584 777 936 - - - HST 12 16 1-1/4" 11-5/8" 10-16d - 730 971 1170 - - - HST 18 16 1-1/4" 17-3/4" 114-16d - 1022 1359 1 1638 - - - HST 22' 16 1-1/4" 21-5/8" 18-16d - 1314 1748 2017 - - - HST 6236 14 2" 33-13/16" 20-16d - 1470 1955 2350 - - HFHA 6 12 1-1/2" 6" 6-16d - 456 606 729 HFHA 9 12 1-1/2" 9" 8-16d - 608 809 972 - - - HFHA 12 12 1.1/2" 11-5/8" 8-16d - 608 809 972 - _ _ HFHA 18 12 1-1/2" 17-3/4" 8-16d - 608 809 972 - - - HFHA 24 12 1-1/2" 23-7/8" 8-16d - 608 809 972 - - - HFHA 30 12 1-1/2" 30" 8-16d - 608 809 972 - HMSTI 26 12 2" 26" 26-10d x 1-1/2" - 1417 1885 2262 - - - HMSTI 36 12 2" 36" 36-10d x 1.1/2" - 1962 2609 3132 - - - HMSTI 48 12 2" 48" 48.10d x 1.1/2' - 2616 3479 4176 - - - HMSTI 60 12 2" 60" 60-10d x 1-1/2" 3270 4349 5220 - - - HMSTI 72 12 2" 72" 72-10d x 1-1/2" - 3924 5219 5709 - - _ HMST 27 12 2" 27" 30-16d (4)1/2" 2280 3032 3645 1405 1869 2250 HMST 37 12 2" 38" 42-16d 6 1/2" 3192 4245 5103 2100 2793 3264 HMST 48 12 2" 48" 50-16d 8 1/2" 3800 5054 5709 2609 3470 4174 HMST 60 10 2" 60" 66-16d 8 1/2" 5280 7022 7279 2694 3583 4310 HMST 72 10 2" 72" 66-16d 8 1/2" 5280 7022 7279 2694 3583 1 4310 HPS 218 7 2" 18" - 4 5/8" - - - 2177 2895 3483 HPS 418 7 4" 18" - 4 5/8" - - - 2177 2895 3483 HPS 720 7 7" 20" - (8)1/2" - - - 2858 3801 4572 HHST2 7 12-112" 21-1/4" 1 - (6)5/8" - - - 3325 4422 5320 HHST 5 7 5" 21-1/4" - (12)5/8" - - - 6650 8844 10640 HHST 3 3 3" 26-1/2" - .(6)3/4.. - - - 4737 6300 7579 HHST 6 3 6" 25-1/2" - 1(12)3/4" - - - 9473 12599 15157 Notes: 1.Uplift loads have been increased for wind with no additional increase allowed 2.Design values for bolts are based on loads being applied parallel with the grain of the wood 3. Design values based on NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION,1991 Edition 4. Wood thickness: HHST2/HHST5=3-1/2"; HHST3/HHST6=4-1/2" 5. Design values may be doubled provided all the following criteria is met: a.Maximum of two of the same connectors per location. b.Care should be used in order that nails are not driven in conflict with each other or the connector. c. Straps or clips must not overlap the other connector. *Also available Twisted "HST22TW" 27 Tatirtrate of Mrruvanru (situ of Atlantic lhac4 — Nloriba Department of Nutldtng Inopeutlin This Certificate issued pursuant to the requirements of Section 103.8 of the Southern Standard j Building Code certifying that at the time of issuance this structure was in compliance with the j various ordinances regulating building construction or use. For the following. Use Classification Siiigle 1'amily, Rmc , 1deyc::a Bldg.Permit No. 8444 Group W/ razz-' Type Construction raj Fire DistricI; ALL-aiaic Be a-ch m n �. Owner of Building �, t t' ' I"i 3 vlZt s i. ,11Ei iidress •7• 7 Crt;,U i>y so 8,jildMn Address 90 O; aTll 6 i)r",Wcality A+:.3.at;tjx Leach, F1, 321'13?; By: DON C. FORD Building Official Date: POST IN A CONSPICUOUS PLACE i MAP SHOWING BOUNDARY S -1VEY OF LOQ' 11,• REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTFIED TO: REf"wrIVEDLARRY E.WALSHAW AND MICHELE D. WALSHAW. COMMONWEALTH LAND TITLE INSURANCE CO. WSW/NORTH FLORIDA.A NATIONAL ASSOCIATION, OCT 1 1997 City of Atlantic Beach Building and Zoning LOT OCEAN BREEZE DRIVE t" ) N89•-43'-35"E 60.00' (R.s u &CA* (PRIVATE ROAD'04 ) L7E43 M DIT POR M+o11E55 t EMS$ 0PAOMA+ANDMMS 7 PAV06 Is•C01�.gt►(K CAPS AM MM7A'AIA.X(10.7) O s ) 12A su x (as) lrD• C0 M LO a � O — — — — - LOT 10 P' EO w� Q $ X(10A) I . 0 X aa j M W tl 3 W CO O to. I o W Z AID 6rer J to'su I lea) X • i xlT9i 60.00' 1'Q S890-O'-35"W rn, J 5' EXISTINGW LL--FIRST FLOOR I i , 31? `roof deck system beam 3 - 2x 12 00 s , GREAT ROOM 1 x 16 concrete caste beam existing ------------------------ COLUMN------ X 4 " STEEL MN SpVs24 GZXe �oRGNO �S��G �P���D�O�( 1MG E �Rodo� ePCK�o ,s Pp R ooR X� P%01 p•N�R�s� ��c E'�ERp`���NGSKP��� KEEP Fit ppp3�4�CEg'PR�� � �S N� �ERR� �� ti� 3�8 A14 ISEC� 8'10 6`11 T- --------------------- ------------ -------------------------------- ' ENGINERED ' TRUSSES-GABLE E D 4-0X4-4 R-30 CEILING INSULA ION OF SEE C EXISTING ROOF CINE b TYPIC DECK � 3-0X4-4 cl PLAN 131 EXISTING -- - --- --- --------------------------------- ------- - EXISTING ROOF BEDROOM ADDITION WALSHAW RESIDENCE as B11 _ a ____________________ ________ ENGINERED TRUSSES-GABLE E14D 4-0X44 -30 CEILING INSULA nok SEE CUT SECTION FOR EXISTING ROOF SINE3-0X4 4 ; b TYPICAL ORIGINAL DECK PLAN 13V EXISTING SHED ROOF ------------------------------------------------------- EXISTING ROOF BEDROOM ADDITION �WALSHAW RESIDENCE SCALE 1/4.1 FT. STRESSWALL PANEL NOTES: 1/2 OSB NAILED 4"O.C.EDGE NEW WALL 6"IN FIELD ----—2X6-16" HUGHES WAM ANCHORED TO O.C. LINTEL WITH 6"X 5/8"RED PLACE ON EXISTING ROOF HEAD—UL#4500 LBS 27 INCH DECK--CUT BACK ROOFING HT. EA. CORNER AND 4 FT. FOR TIE DOWNS AND RE-SEAL 24 EACH 9 MM NAILS R-19 INSULATION HUGHES TP6X EACH STUD WALLS AND ENTIRE WALL UL#1465 FLOOR 10 EACH 9 MM NAILS VAPOR SHIELD _.._ .._ .. .....__. STUCCO TO MATCH 77S, -41 IL I---ALP llk�e ?�DE) 770 7- -i 0 2- C 4 -2 f-:.I ?5 1D AR Y SURVE-) p AT CD C N F`R E E7 F, L_ 61 V�M Q U ti R F CID LIZ L I CEP.TR-';L:L1 7,1: WALSHAW, E,W H AW A N___D V SONSANK NORT4 F'-QR,c, t4AT iQoAL ASAOCIAT0,4. 2 A 1995 Building and Zoning 1.OT I tT E F. 7 E NVE ,:DCe E,�IN E,R q CAP DIP. ( i040 4 LB b SSP? _7 7 x i0L A-A L It' LOT 'C, 3 b �Jl FIN Ft.Qk-lp LLJ 20. OAA L<o, �� 3z 7 - 2T SAJ 12.Q&K 12 'JA AK QtK 0'QAK _ 60,00— r�AA IN-- po cr FENCE RkVtSCO it-4-214 TO SHOW FINAL mpmovkmwwF.��`_O- SHQW-s ARE FCft04.11 CITY OF ��a!�tutic �t�'raek - �l�r:iaht 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 31133-5.445 TELEPHONE(904)247-SM FAX(904)247-5805 NOTICE TO: Nater Department FROM: Building Department DATE: �Y 7 Please be advised that the final building inspection has been completed on each of the following addresses and construction Water is no longer needed: Permit Humber Address r relj, Building Department ' 4'ZIN CITY OF 'R:;:,Kh-,''I DESCP,IPTION r L � � �,�oy�3�`' r��tc cT�:t<< L`�c•%I cl - 'c�:c�,: 800 14-A11\01 I Block N Section M ' ` { A7L%.NI It' IlFAt11. F ()K1D% .I::II 111111110S'1.:19011 247-.481111 1%X (9041 247-:8114; ;ubdlvision:_Rev_is-- flat_ of -Ocean -Br z street Name DESCRIPTION OF WORK )r Addrens: If in a FLOOD HAZARD nrea complete page 3. Brief Description:_.1ew-House.-3000_- sq_.f t . Claes of Work: New (New/Remodel/Addition)_________ _____ ONING INFORMATION Type of Construction: Formed concrete ----------------- oning // )) Proposed Eotimated Value 160000.-00 xceptions or hater iale; ____ Poured _Concrete____ ariances Granteds------------------------- Solid or __---------------------------------------- Filled Grounds Hoof: Trussed ------------- OWNER INFORMATION Method of Heating:_- Elect.- and-gas Property Owners_Larry_and Michelle Walshaw Phonon354-5820 --------------------.._____ -------------- Moiling 2139 Seminole Rd . ' Atlantic Bch. 32222 Address----------^------ ------------------------------- ------------------------------------------------- Zip: 32222 --- ------- CONTRACTOR INFORMATION Contractor: ---- y___-_-_-_------------- Phonc:--3-5-4---5--8-2-0 Mailing - --- Addreps2715 Forest_Street----............................ Jacksonville, FL 32204 32204 -----^------------------------------------------ zip--------------- - - CGC 010978 Expire h". 31 1994 License Numbers ----------------------------- Dates Date s I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THC GAnE T" CE Tru-r 1ANP CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES OOVERHIHTHITYPE 6F rgr t- J COMPO S VC )q?WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT 00r-3 N•1r rrc *"^f •r GIVE AUTHORITY TO VIOLATE OR CANCCL THE PRUVISiONS OF ANY FVOCRAL, STATE OH t.cAl t r,S•- �,! t- REGULATION3, ORDINANCi.9, Oq LAW3 IN ANY MANNE)t, INCLUnTrin THL GOVFRlIINn Or C fl':TPI: T7( •+ PERFORMANCC OF CONSTRUCTION OF TPIr PROJECT. I UNUER:.TAND T T THE I'S::UAHCE OF T'-I.: VLf,^:- CONTINGENT UPON THE Above INFONMATION DEINO THUG A L'ONREC HD THAT THE PLAN-, AHo 1 DATA HAVE DEER OR SHALL bC PROVIDED A; REUU R •D. ••• ' ��� �3 1 Ovner Signature Date/ • r Contractor SiQ»eta a ote_.3^��/y `off PSR t E S i x _ DEPARTMENT Qin BUILDING IF CITY OF ATLANTIC OFEAGH PERM 1T IMFORNA ON LOCATION INFO" J,O �rmit Nu r. `9435 Address 9th CC � BREEZE DRIVE�� A. B Fermat T pe- PLaUMBI,N �TF AN'TI BEACH,. FLORIDA 32233. 'L -or,4, ------- `PZQAL DESCRI.P'TIOX i---,.---- „' ans tTTP+ WOOD FRAI+i Lot ; S ck s Section" FrpeA SIMOL. FAIK+lILX TRMI : i Code,. Q Subdi,�dsiion: OCEAN BREEZE 1"'st. mated u , ` o �oo 1,Ctp r+C v1 S t $01,00 Total z' - X25 .00 Amona 14 1.9VAIrl? 4124 t {: plft A TIOtf " ASHN PERMIT2C � fSR �?IT�TF . . NPACVXr esR� �. $0 .0 T Chi, P'LTOF I m � �` � t �e �"�S " d 5' ,m'`p vi :g,n- a 'hr.=�°" �` LT.. ^r. a '3 Arisa`ft RAL QIP d3AB H Ft SO 00 _ F. SIOIISSAP OCAPITL . tP .3V1 `, JA` T , I L,L E, .FL '32225 CROSS CONNECTION Type, 0 SRC R I+fPA T PE CORST SURCHARGE Elm �-� mo q { E v � r NOTICE. AlL CONCRETE FORNiBAND FOOTINGS MUST 8E INSPECTED BEFORE.POURING ' PERMIT VOID SIX MONTHS AFTER DATE OF'issu f 5UDING MATE RI L'RUEfIIlSW AND QBAISROM THIS WtRK(1riUS NOT iAC>=D IN P1�8lIG SPACE, 9l+ _ lIJT 1j OL RED UP AND, A 1lED AWAY t Y EITHER CONTRACTOR OR OVIIMER 7, `III .URE T Ct�MI�1.Y WITH THE MECHAi� ICS' LIEN IAYV CAN, RES' # P iOPE PAYING TWICE F61A U04 NO 11�IPI�C��'�II�1 ' f RDIN ,T® APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SU'SJECT:Tt� ' FAP ASL, 1 tiSitNatS'+OF LAW. AT A DTIC BEACH BU OtNG DEPARTMENT CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT JOB LOCATION lIDL JCeA K-� l'E'C Z e ONNER OF PROPERTY: !' 4 114 l`s, �� �-S� Z4 4 BUILDING CONTRACTOR: PLUMBING CONTRACTOR l/�AfA:T t Q P `\�C 06-PJ S_+ t,_ vob S c' t lo AND ADDRESS: -- TELEPHONE NUMBER: .S3 o STATE LICENSE NO: TYPE OF BUILDING: TYPE OF WORK: RON MANY OF THE FOLLOWING FIXTURES INSTALLED SINKS SHOWERS LAVATORY NATER HEATERS BATH TUBE DISHNASEERS -URINALS DIBPOSALS CLOSETS IASHINO MACHINE FLOOR DRAINB BROKER PANS OTHER -1- 16-A'j)o r� TOTAL FIXTURE COUNT: x $3.50 + $15.00 = $ ---------------------------------------------------------------- INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS - (904) 247-3826 SEWER CONNECTIONS MUST BE CALLED INTO PUBLIC WORKS FOR INSPECTION WORE COVERING UP - (904) 247-5834 DATE: PRE—SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY 233 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTION(S) HAVE BEEN MADE AND ARE SATISFACTORYs i,------ ----------- _-------------------------------- �i 4N - --------------- ------ ------------------------------------------------- ------------------------------------------------1 Enclosed are the blue copies of the permits. SI LY, BUILDING INSPECTION DIVISION cc:FILE $MA , A October 20, 1994 ONEY Cons— u' alongEngineers,Inc. I Mr. Don Ford Chief Building inspector City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233-4381 Re: Mr. and Mrs . Larry Walshaw Lot 11, Ocean Breeze Dr. , Atlantic Beach SJM #1545 Dear Mr. Ford: After site inspection on 10/6/94 of the above referenced project addition of a Glue Lam Beam, it appears the construction meets the 1994 Standard Building Code requirements for wind loads, except for the following: ll Tighten down bolts and/or 2) Add 3" long 3"X3"XW" (structure angle under Glue Lam Beam if you have any questions, please call me at 904/264-1377 . Sincerely, STONE, JOCA & bWON>rY, INC. AW-PROVED CITY OF A i LAN 11C BEACH BUILDING OFFICE John J. Mahoney, P.E. CT 2 Vice President 8 JJM/gi 1994 ' [ line ur,d Zoninor Foxwood Center Suite D 1730 Kingsley Avenue Orange Park, Florida 32073 (904) 264-1377 Fax (904) 278.8469 Sys .i Z i i j i �CfJ7 {�' py.I b4 An/G-I EX n,A.rc1+ YC F.•I�Sf. --� Co,.rR�C/�s;� $s�+rv► F T ��`�'N',, R.19 � I -� _ 1t�C .j 4G �S — — — 2X8 ►co — ui � aa4o O.C. FULL �-'r-tx GOL. 0 a ff�s� i iS 9 o�,c, Z� S•eve 7zLcJPs-i is J 9/"/9y WA LSHA e CJTY O1' office cif Building Official c1l Z 7 r"' REQUEST FOR INSPECTI )IN Date_----/�_�--�f—_ —------__ Permit No. Time A.1,1 Received -- LG! L1----RM. Job Address Locality ,dv8sr�.e,� Owner's — �6nt----,actor — -- 3UiL NG CONCRETE ELE�I,RICAL PLUM 1iV�___ R{E AL Footing Rough Winn i Rough Air o He Roofing Slab Temp Top Out Heating Insulation Lintel a Sewer I Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. Tues 4 !1- Wed. Thurs. Friday P.M. A . Fir�af to erL�icaie of coupcncy f)ntr. pCITY OF 4&40d4c 3e4cJs-//f& Office of Building Official REQUEST FOR INSPECTION Date / Permit No. ` Time A.M. Received P.M. Job Address Locality lBUILOwner's Name �-Contractor DING CONCRETE EL CTRE ICAL �} PLUCHANICAL Framing ❑ Footing ❑ Rough Wmng ❑ Rough ❑ Air Cond. & ❑ Re_j(Qo Slab 11Temp Pole F] Top Out ❑ Heating nsulation Lintel ❑ Final L Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION Mon. Tues. /1Med. ) Thurs. Friday CNF �' A.M. Inspection Made Inspector ' _ Final Inspection ❑ Certificate of Occupancy❑ Date G CiT F OF /' ! ,y AR a'S f ,Fnc VY `� rs.r�.Fd.de zr� {° .i t)y ,��( Office of au ding Official REQUEST FOR 1r`SPECT1'0 ,4/ / ✓ � _ fir ! _ ����� �, Date Permit No. — _ — --- _- r ecewed -------- --- P.M Job Address �pp� me .----(-"t> - _ ZLj _ _ Contractor - -- --- -'f EDi.+ a— CONCRETE �L_E�C7�RlCA't �Lt�BI_NG ;, riECHAANiC�AL' Framin '� Footing �"" out—rh wiring o—Fi ugh e ,00iing Slab Temp Pole Top Out Heating Insulation Lintel Final Sewer Fire Place Pre Fab ti READY FOR INISPECTION A.M. rues. Ned Y- `�iu / Friday - ------P.M. s a Cyr' .. / % .. inr�,-,teen A _cie _ - 1 Inspection C e r T!,ate of Occupancy �� �- , � TRANSMITTAL DOCUMENT FOR JEA DATE: /U - -� --� - C,/ The following permits have passed "rough" inspection: Permit No. Address �_ ,q �C 31 C-5 le Rnckm s►cmzoKxx=xgtxkua*=Opdxsxa&xbk=V=xd*u. Please update your records accordingly. 1 hank�/ BUILDING CLERK CITY OF ATLANTIC BEACH /vcb p6 ' F 9,127 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH ` PERMI INP'OP ------ - 'LOCATION, INFORMATION --------- P , I tzt Numb OCEAN B a 912" Address . 90IREEZE DRIVE 'elzmit TY et MECHANICAL ATLANTIC BEACH, FLORIDA 522 1 0 S of 'Wo k. N9W . , _--- LEGAL i?ESCRIPTION ,s t r . Ty e a WOOL FRAME Lot * 81 ick> ' Sept i cin, F ,� osed Use-. SINGLE F'.AMIL)t k( 1 €�d { Subdivision-. OCEAN BREEZE E asst V ue,: $0 .00 mrlpv.. st . SCI ,Q ► €0- i Amoun $93 .00 T< REXT AM.) APPLICATION FEES t �PERMIT 93.00 ?! * ► ',; BREE Z DRIVE, x >—WA IMFAC` FEE ' a o .90 44, d 'WP ' Pkv IETAt�E1'AI' 3.tt RADON GA.S-R.R. S. $0 .-00 r T Com ' { � NAI3#3N " SAB G► t# , MRS.- Cry. � CAFE�k"AIr.:.LMPR�+VE, ESI:DOr CE BLVD. SEWER TAS2246 , . <e' CROS CC�NNE�I OpI 00 Type. SES' H TMFACT FEE SCHA 09 'ATL.BCH. :No- NOTICE t a i i Nt?TiCE BALL C4NCREtE FORMS AND FOOTINGS MUST of INSPECTED"13EF©RE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE u UIWING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE Ct ' ReD UP AND H ULED AWAY BY EITHER CONTRACTOR OR OWNER 3, " ILURE T CCtMPI.Y WITH THE MECHANICS' LIEN LAIN CAN RE SULTS IN " Rt3PE TY11NR PAYING TWICE FOR,BUILDING IMPROVEMENTS ACC©ftC3IN. TO APPROVED PLANS. WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION f*Ofl TI1� ?F AIIL ABLE PR©V1i510NS C3F LAIN, ATLA #C BEACH BUILDING DEPARTMENT p�ppp �� 14 motes 1 0 Rept: L579 BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC BEACH, FLORIDA 82298 APPLICATION ,AOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT — Applicant to complete all items in sections I, II, III, and IV. LOCATION Street Address: OF Intersecting Streets: Optween And` BUILDING �, SubdivisionQL II. IDENTIFICATION -- To be completed by all applicants, In consideration of permitgiven for doing the work as described in the above statement we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Jacksonville ordinances and stondards of good-practice listed therein, Name of Mechanical - Contractors " / Contractor (Print) Master /•� Name of Property Owner Signature of Owner �� Signetun of or Authorised Agent Architect or Engineer III. GENERAL INFORMATION A, Type of hooting fuel: 6• IS OTHER CONSTRUCTION BEING D�ON�-�E ON THIS BUILDING OR SITE S 1oiD ❑ Gas•—❑ LP Q NoNrel ❑ Central Utility 0 C) Oil IF YES, GIVE NUMUFOR OF CONSTRUCTION ❑ Other-- Specify PERMIT IV. MECHANICAL EQUIPMENT TO 6E INSTALLED NATURE OF WORK (Provide complete list of components on beck of this form) 0Residential or ❑ Commercial Heat Q Space ❑ Recessed 112''•hentral O Floor _2--Iq_aW Building .r Air Conditioning: Q Room Cr Centre) ❑ Existing Building ,,$—`Duct System: Materia► Thickness- ❑ Replacement of existing system U Maximum capacity 11) r t�� c,f,m, --D--"New Instailation(No system previously installed) -- (3 Refrigeration Cl Extension or add-on to existing system ❑ Other -- Specify [� Cooling tower: Capacity g.p•sn. ❑ Fire sprinklers: Number of heads ❑ Hwetor Q Manlift Q Escalator (number) THIS SPACE FOR OFFICE USE ONLY ❑:G4wine pumps (number) �; ) ❑, Tanks (number) Remarks ❑ LPG containeK (number) ❑ Unfired pressure vassal ❑ bilen Permit Approved by Dote 0 Other — Specify Permit Fe. LIST ALL EQUIPMENT AIR CONDITIONING AND REFRIGERATION EQUIPMENT Capacity A F '�►i �'L Number Units Description Yodel Number anutscturer ��`b�n�a Cy 1(�_iCA �— — 4..� y r r z. ter ar .3 C 4 5 -DSPAR'�'ilr 1 I'C It"BUIL.© 1 � V00"00 UQo CITY OF AT'ANTiG BEAM . I 'Pop ERMI� lBFCtPXATI01i LOCATIt?N' I19P�R�,�1�% , Numbr 8444 r Addre'Sa0 50 OCEAN BRERE ++��, ' Y * SBU I L'I N , ) A.'TT.AI`T�I yy;� A �yy -FLOR I C a `yXf WW .NE ) lBMs ww., rrn w.q LOCAL DM$ 1hT rj on r. `' w � "" �3 L�at3 Bfivkm° tcn: F r sed U 4 S1,40I�E , 'LILY Town�hip� RNA. t� �r � �.I Codep � •- � Subdivision: OCEAN 'BREEZE Improv. cyst : SO4 Q 038 9. 52 �Arh W D rf »k. tE SINGLE FAM IIY RESIDENCE PER � ,5,, HSS` -2721-RD�-1402 A '0LICAT ION � FEES - Z K' tal, PERK 1-T t,1036. 513Al .... A , . SIE' RbAT3 WATER IMPACT FEE $650 .04 { � 1 CRR � ' B 1 ' `EE250''10 ' r " 0, T ` , { RACK ' t? . 5 ' WIC: Q 00 '. ,CAP TAL IMRFtCuE 2Md3C0SEWER -TA 011 ' G 4 00 * A 1LM', FL. 2 4 CROSS &3� v✓TIf}>V. $3 5 .{?Q A� •. a 'a` y� +51 , 1,. Il '19 '1" F 0- 'f 'jot , r � m + ,•gyp „„wa� nsm��d' .�• �, ,.��b —� �"� h . T 6 4 1 4 f I~tO CE, ALL CON RET PC1RM8.AN0 FO&INGS MUSt 8E.INI;PB T L� .4,FORE POUR114G PEFItu11 V,QiC3 SIX.MONTHS AFTER DATE OF 1SRl 1 1,5 B �NG-MATER) Lt RUBBISH AND 0EB1�F 0M THIS`WVORK MUST NQS`BE PLACED IN�PU8,LI��PACE,AN[�MU � CI. ARd UP ANISALILED AWAY BY EITHER CQWTRACTft OR OWNER r A E ' GC1 LWITH T HA�11��' i�� tA?�t SAN RESULT Ill RCP OWNER PAYING CE �a 3U1Lb `1�+R PR0 M t T �” i C �4� t3R[ I 13 Tp APfR10Ep P'Ll1NS:1A/HICM AR PAi ,?UF.,?HIS PERMIT ANQSUB,�E 70 REVtATISN��FCIR 1/tTIcN Df A #C13LE°IF#U�Iffiif'LAW i „ 1 } TMEt s. 00000m 'L4 k 0 4: I +. a gird ,r _," a CITY O,,tti- / - .�.5 4 Office of Building Official f REQUEST FOR INSPECTION b �t Date_ _= Permit N _ Time 21a Received — _P.M. Job Address � Loc it i Owner's Name _ _Contractor BUILDING CON>RETE ELECTRICAL UNIBING MECH AL Framing _ Rough Wiring 1 , Rough ; AirCo d. & � Re Rooting Slab Temp Pole Top Out Heating Insulation Lintel D Final i Sewer Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. Mon. Tues. Wed. Thurs. GD— Inspection A.M. -- Made _ 70? � Y M. !0 Final Ins ,ction t I Certificate of Occupancy J F),tr- CITY OF 4&4w44'c Be A-&7k J' Office of Building Official REQUEST FOR INSPECTION Date Permit No. Time A.M. Received P.M. J Job Address Locality wner's ame Contractor =si l_r (� WILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Iring"' _ Rough 1:1Air Cond. & El Re Roofing 11 Slab El Temp Pole Top Out ❑ Heating Insulation ❑ Lintel Cl Final ❑ Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION f A.M. Mon. Tues. Wed.J Thurs. FridayP.M. Inspection Made _ . Inspector Final Inspection ❑ ertificate of Occupancy ❑ Date Office of Building Official REQUEST FOR INSPECTION �_ Permit No. DateP _, -- _ — � Time A.M. Received Job Address ocality Owner's / f ,Contractor Name _ -- BUILDING TE ELECTRICAL PLUMBING MECHANICAL Framing i Footing Rough Wiring Rough Air Cond. & Re Roofing r, Temp Pole Top Out Heating ulation [7 Li tel f Pre Fab Final Sewer C; Fire Place 17 ,t r� 147Tli� 4-READY FOR INSPECTION ---- A.M,,) Mon. Tues. Wed. Thurs. CFn -/ A.M. Inspectior. Made _ _—__---__---- PM. Inspector__ � _�-- _. _ Final Inspection !-1 J� Certificate of Occupancy Date CITY OF 4&TQC 13e.�- lf- Office of Building Official REQUEST POFD INSPECTION Date ___ ��^_.___ __ Permit No. Time f A.M. Received _1 __P.M. Job Address Locality Owner's I& Name ___ --^__Contractor BUILDING CONCRETE ELECTRICAL PLUMBINd MECHANICAL Framing = Footi ri Rough Wiring [ ! Rough C Air Cond. & Re Roofing la Temp Pole Top Out ❑ Heating Insulation _ Lintel 0 Final Fl Sewer Fire Place Pre Fab READY FOR INSPECTION A.M. Mon. Tues. W� Thurs. Friday Inspection Made Final Inspection J Certificate of Occupancy Date ` /CITY OF!3 iq&aa4C wa4•Qb"* Office of Building Official REQUEST FOR INSPECTION v Date___ -7—/ Y-9 Permi No. U Time �� A.M. Received M. Job Address ocality Owner's Name Contractor BUILDING '�� ELECTRICAL PLUMBING CHANICAL Framing Rough Wiring C Rough ❑ Air Cond. & ❑ Re Roofing - Slab Temp Pole Top Out ❑ Heating Insulation _ Lintel __ Final Sewer ❑ Fire Place ❑ Pre Fab READY FOR fNSPECTION Mon. Tues. Wed. Thurs. Friday_ A.M. Inspection Made '�f���1,L—_— ?.M.ed1qC-,/7e inspector �-t- �-�-� �- Final Inspection❑ Certificate of Occupancy F-- Date Date CITY OF 4 � B Office of Building Official REQUEST FOR INSPECTION Date . (/ C Permit No.. � _ Time 0 0 A4 Received Job Addres o ity Owner's Name Contractor BUILDING CONCRET ELECTRICAL PLUMBING MECHANICAL Framing ❑ o ing i, Rough Wiring ❑ Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab rl Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel Final ❑ Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION Mon. Tues, Wed, Thurs. Friday A.M. Inspection Made P.M. Inspector < -�✓" Final Inspection Certificate of Occupancy ❑ Date CITY OF 6mdt- Office of Building Official Q REQUEST FOR INSPECTION Date _ G —_ Permit No. v �� Time A.M. Received ! U _ pM, ——— Job Agidress — — — Locality --- — Owner's C Name ��J��—L -------Contractor �L3'd BUILDING E-1 ELECTRICAL PLUMBING MECHANICAL Framing _ Rough Wiring Rough ❑ Air Cond. & Re Roofing C Slab 1-1 Temp Pole Top Out Heating Insulation ❑ Lintel Final Sewer Fire Place Pre Fab READY FOR INSPECTION A. Mon. Tues d. Thurs. Friday F Inspection Made P.M. Inspector_ _�� na! Inspection — -- Certificate of Occupancy Date CITY OF \1V` Office of Building Official REQUEST FOR INSPECTION Date-----_-- - -5 C Permit N --- Time Received P.M. ----Job ddres- Locality — (.,J Name ___--__—Contractor _V _-C-2_ BUILDING CONCRETE ELECTRICAL PLUMBING:—: ECHANICAL Framing Footing Rough Wiring Rough Air Cond. & rn ❑ Re Roofing Slab �' Tep Pole Top Out I Heating Insulation Lintel J Final Sewer C': Fire Place C Pre Fab READY FOR INSPECTION Mon. Tue=. Inspection Made Final Inspection 71 Certificate of Occupancy Date _ OF ADDITIONS or • " • • NOT REMOVE JOB ADDRESS DATE THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted It is unlawful for any Carpenter, Contractor, Builder, or other persons, to cover or cause to be covered, any part of the work with flooring, loth, earth or other material, until the proper inspector hos had ample time to approve the installation. -V�A e After additions.or corrections have been made,/call _ '1 _ Building Department for an inspection. Field Inspectors are in the office from - to Monday through Friday. PLUMBING ./ ELEC. BLDG B-4 PRESS PRESS HARD-USE BAIL POINT PEN CITY OF ATLANTIC BEACH N- T 2548 FLORIDA NAME— Q -'� L" ADDRESS 61 7/ 3- -O/Lae-L si' CITY 4. 3 - 9Co r 0 'T" 4/L 0 ffSD-� When Signed, Dated and Numbered, This Becomes an 0600 0MM 00 $15.00 74 Received Pa 7/05/ O1 Rcpt: 0064220 MAKE CHECKS PAYABLE TO ytkl S 11707 CITY OF ATLANTIC BEACH, FLORIDA TRF.ASURER �a aea� 0 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PERMIT IRF' dot 1ATI4AI r; — LOCATION INFORMATION `�_ �� _.�--- l�.. Number- 8890 Address:m ` 0 OCEAN BREEZE DRIVE ;P r:rftit- Type: BUILDIN11 ATLANTIC BEACH, FLORIDA 3`.2 233 C of Work: ADDITION LWAL DESCRIPTION zType- WOOD FRAME L 11 13 1 oc,k t"u o Use BINDLE FAMILY Township,, RNOt DOIIin 9 z 1L Subdivt on: OCEAN BREEZE T10t i peel $40 00 s Dat ? a/94 t; Dig. L A'IER IMPACT FEE FOR SHOWER M TION APP LIC TION FEE� , PERM IT . s f� REE E DR&E' x. � , WA'T'ER 04PAOT FEE 4 .D A,07 3 { tlACH , FLORIDA 3 p'' T AP < ; fi INFORMATION RADON CAB 5 O. 00 . . Ne CAPITAL IMPROVE' A AcR STREET � w SEWER TAMP.. , ....... 116, -ONI ECT I Ott ? BEC H IMPACT PEE 4 . °, r ONBT: I RCHAROEall, HARGE/ATL BCH q O s., a i NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED SEFORE.P4URING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BLIILD NG MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED JN PUBLIC SPACE,AND MUST BE CLEARED UP'AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER � � a ALLURE TO COMP Y WITH THE MECHANICS' LIEN, LAWN RESU . IN SNE PROP RTY OWNER RAYING TWICE FOR BUILOING IMPROVEMENT.}' p41 Gi?RD1NC TQ APPROVED PLANS WHICH ARk PART OF THIS PERMIT AND SUBJECT TO REVOCATIO41 FOR T OE APPL#CABI.E'I O1/FSION5 OF LAW. 000000004 00000t?000 14.4E) 14 SErIH 8L1ILrDiNta DEPARTMENTIlato 5 8106!54 01 t1607 CITY OF �tl4at�tie �►cac� - �G�tcda 800 SEMINOLE ROAD - --- ATLANTIC BEACH,FLORIDA 31233.3445 TELEPHONE(904)247-5800 FAX(904)247-5505 August 3, 1994 J. E. Crosby Company 715 Forest Street Jacksonville, FL 32204 Re: Larry and Michelle Walshaw� 6 90 Ocean BreezeDrive Dear Sirs : Our inspections have revealed an outside shower has been added to the building at 90 Ocean Breeze Drive. Please remit $40.00 which represents additional water impact fee due to the City of Atlantic Beach. The Certificate of Occupancy will not be issued until this item has been paid. If you have any questions please contact this office. Sincerely, C Don C. Ford - Building Official DCF/pah cc: Mr. and Mrs. Larry Walshaw City Manager CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET OCF-ofN 6AEE7-f= arf Sauare Footage ��a @ s per sq ft = $ f 4 ` S carat _ nerl Ca $ per sq ft = $ i —3f--() per sq ft = 1�Cd $ per sq ft = $ ar_ C @ $ per sq ft = $ TOTAL VALUATION : /7Y Tr,-Lal Valuatign lst $ /00,00 a Remaining Value per thousand or portion thereof !� TOTAL BUILDING FEE $_ + 1/2 Filing Fee $ R ;� (a-) Fireplaces @ $15 . 00 $ 30.00 BUILDING PERMIT FEE $ 10305z WATER IMPACT FEE $^� SEWER IMPACT FEF. $ 0e) WATER METER/TAP $ d,OB CAPITAL IMPROVEMENT $ .32S00 _ SEWER TAP $ 0 0/04, RADON (HRS) .0050 S -7 SECTION H PAVING ( ) $ — HYDRAULIC SHARES $ ©— _ CROSS CONNECTION $ �.®4 V4YOX SURCHARGE . 0050 OTHER $ GRAND TOTAL DUE $ ADDITIONAL PERMITS OR FEES: Mechanical Plumbing G: f-rtric/New Electric/Temp ; SwimmingPool Sep- ;c Tank ; Well Sign_ Finish Floor Elevation SU,vOther C?1; -'ULATIONS and/or NOTES: FLOODPLAIN DEVELOPMENT INFORMATION Type of Developments__ Residential houses _____________________ Flood Zone;___ 'X- ---------------- Required Lowest Floor Elevations_______________ If building is located within a flood 'hazard zone, a survey must be shade AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base :flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgements I understand that the issuance of this permit Am contingent upon the above information being correct and Lhat the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. Date_5�� Applicant's Signat ----------------------------------------------------- Department Use Required Lowest Floor Elevation As Built Lowest Floor Elevation Survey Filed Filed with Building Deportment ___________ Building�Department Representative pages 3 CITY OF ATLANTIC BEACH Fixture Unit Worksheet for Water Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT TWENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF C) SERVICE SINK TRAP STAND WATER CLOSET, LAVATORY & BATH (8) TUB OR SHOWER STALL (6) IF WATER CLOSET WATER CLOSET, TANK OPERATED (4) VALVE OPERATED (8) BATHTUB/SHOWER (2) URINAL WALL LIP (4) SHOWER GROUP PER HEAD (3) / FLOOR DRAIN (1) SHOWER STALL DOMESTIC (2) 1 LAUNDRY TRAY (2) LAVATORY (1) 'L 6 COMBINATION SINK AND TRAY (3) IWASHING MACHINE (3) 3 ::r—POT, SCULLERY SINK (4) DISHWASHER (2) 2- WASH SINK EACH SET OF V FAUCETS (2) KITCHEN SINK (2) DENTAL LAVATORY (1) KITCHEN SINK WITH WASTES" DENTAL UNIT OR CUSPIDOR (1) GRINDER (3) BIDET (3) URINAL STALL, WASHOUT (4) FLUSHING RIM SINK (8) TCOMBINATION SINK AND TRAY WITH FOOD DISPOS. (4) URINAL, PEDESTAL, SYPHON JET DRINKING FOUNTAIN (1/2) BLOWOUT (2) LAVATORY, BARBER/BEAUTY ICE MAKER (1/2) Sf SHOP (2) MM SURGEONS SINK (3) V LAVATORY, SURGEONS (2) JACUZZI (2) 2 URINAL STALL, WASHOUT (4) TOTAL FIXTURE UNITS 3), ✓ @ $20.00 EACH $ JOB INFORMATION Q c /� ,Q� L, '�� F'IG'HT-J 1OAl2 AN) E*4QUI1-'1XE'W* !6"'UHAMAT For: 1. E. Crosl,kv Sy: AIR DWTrVEEA'S, INC Plan § 2Tl Sq. Ft.. Jacksonville"W1 f'-12one WTAW"'Al OES16H COADINONS 54YffiYj,".'7? CONOI 11ON Outside dil. 3Y Oeg F Outside & - Q4 Deg F Inside, db: 1;;'0 1,7eg F fnside,. cffi: lev F Oesign 77"): 38 Oep l7esi?"a t 17eg F 1,78ily "I"?ange Huf#. 50 Wdtef' Yr r14FA i'hW SL"AT 3k.W5'I'8U*.,' C06,'111V6, &M11P !OAI,*, 812HWI., ...... . gldg. Heat loss 4314.;;" 8tah 3t 4 ...1,uc t'Ure t 0/-U / Vent-ilation Air 0 CFH 0 81 uh k'ent Air loss 0 8tub Oesign Amp. Swing 3.0 Oey F 0e'Sign Heat load 4314�; 8t'l."h Use Alfy. Odtd il Alate/Swiog Hult. 1.6161, otd-I., Sea".> E41jill", load 4,412"", Z I V I- TU I IiV1l1 TAIA IYON 141'DV1- C001 IN*, EQUIP I u"'A!,', Const Oual a # Fireplaces 0 Internal adias8,0 E:'tuir 1-,'entiIat*ioo 61, 6t1uh HEANM-',' C0011MG jnfill'(dtioo 6'0�6 Stah Area (Sq. ft.) 2,`21 2,;T1 Tot 1&tent' Equip load ';'819'6 81*u/1 1"Waxe (cu. ft. 2,;;'210 2,;;'210 Air 0. ;;,, Cr.4 1*6t&l EQUiD load 5'V Equivalent CFN 318 182 HEAT NIG EOVII-WENT SviVAMR),' COOZING E9UJ;1Ph1L-"N7 3UKXA/iT Alake leonox Na ke 1.eaas-t'k IYO de I Ato de I 7)lpe Air Handler, fyoe Hv.-a 1 Pump EY ficiency / HS'Pf", COWEEP91SETA, 61, 0, Heat'ing In't"'Ut* 0 Ht al? Sensible Coolag 64 uh Hi-,,dting Output 0 stuh latent Cooling Cr 6tuh 14 "e'ating Rise Cr0 Ole F 7'ot-dj Cooling t 8 1-ah Actual HeatIng Fan 26,,'2 CFi,f 4ctudl Cooling Fa n 26"S2 e"Fill Ht;; Air Flow Fdctor 0.061 Cl"M18ta1? Cly Air Fdow Factor 0.,053 CFiY161ah Spdce l'bei-mostat. load Sens Heat`' Ratio 86 ( ./17MYUR,'. J; ./'&M cul /r /r ,p .F r'<.1RRI ./., I� w.. .r F1. 4 J 1�'ri�ntvut certified by AC04 to meet all requirerttents o tFJC?nua( 7"{.frm RJVH&J C,'AL CUL A 11ON' PM.EDI)R S A,8,C,0 Job fir: i._22-,.94 Procedure A - Ali,'nter Infiltration HTH Calculation')' ----------------------------------------------------------------------- 1 1. Winter Infiltr'ati'on CFM r' j 11 j 2. Winter Infiltration Stub r` .31f3 CFH x 38 Winter IV 132,'16 Stuh j +r / j 3.. Winter Infiltration HTH !1 MOW 8tuit / 556 Total Firmrtdvw - 23. 9 H!'r4f j j S Cruor Area r' ---------------------------------------------------------------------- Procedure 8 -- Summer Infiltration HTH C;`alculatioO ---------------------------------------------------------------------- j 1. Summer Infiltration CFM 1' j 0. 4 ACAP x 21210 Cu.Ft. x 0.016 1c32 CFH r+ j 2. Summer Infiltration Stub j 1. 1 x 7 S'2 CFM x 19 S'urirrtter TO -- 3199, S i"uJr j j 3. Summer I n triI tra t ion HTM / j 99 Stuh 556 Total Window - 6.8 HTH r' / S Ooor Area r` --------------------------------------------------------------------- Procedure C •- Latent Infi'ltrati'on Gain , s.. Lk.68Y x 4;9., yr di'trF. ,K 782Grt`t -- 6051 Fs't uJr j --------------------------------------------------------------------- Procedure 0 -- Equipment Sizing loads ---------------------------------------------------------------------- Sensible Sizing Load f / i. / Sensible f'entilation Lind / j 1. 1 x 0 fent.CF61 x /9 summer TO C+ cs't ah r' j Sensible goad for Structure (line 19) r 4 221 stah r' j Surtt of f'entilation arra` Structure loads - 45'221 St ah / j Rating i'nc.Y and Tempera t ore Swing Nul t"i'ol i'e x 1.00 RSH j j &cri'PMent Sizing Load -- Sensible 45'221 S`tiih r, j 2. latent Sizing Load j latent fentilation Load / 0.,68 x 0 kent.CFAI x 49 ,fir.diff. j Internal Loads .. 230 x 8 No. FWavle f 1840 SM rf / Infiltration Load From A'rocedure C f Mi? 81 rih j / F..cTuipment Siting coed .... Latent - 785V cs`tuh r+ --------------------------------------------------------------------- "Construction luality is: a No. of Fireplaces is: C% MANUAL ,.T: Ith Ed. RIMP& PLO TR2973 U " — OIGHT-J: .." 4re J �f' Ent - I y!coo I 198,0 "em "Lab --ed Nal or cgpo,5 F - tiont 09 Op I.,f.men",- L' pun -it' ,,ON coot k - I Area I Hrm noth! Ax 01 jqtej yypE I OF h"4C. 0 1, 17 Ogg 1 '3 MIT /81140 01 0,611 01 'x 0 ot o I v- galIdl ox, 01 5161 Qgjtl let 0,01 01 01 of o o I 61 01 o' o qindo A"6 Idl 2,26,31 I I e f I 4 Not 4101 1 1, :BLit I HE01 CIT WSW 01 f SO - CIA 6991 416, 01 z 401 01 01 ---- 41 Av 00 C,461 0, e 01 01 ("-" ' ofol 01I of C, Jqe o o VI d 1 '"o 1t1 0.o ().o 8 100 0-o 38 C'51 - 166-31 o 01 2,31 160 lot Ge 6094 o 6 loorS 0 01 0,0 F 1 0-0/ A- o2251 ow?, lost trg g*x MOW q15Y)bto- Ht-uh 1056 13+14 OWLI wou vy muum m wom all r wwvAy cme"L, V , sm"UaA w MARVAI A 7th Ed. RIM&A V1. 72 TR2973' A114-W I'*--,)* WIN00W OA M Job P 022-94 w 8 0 At G I S 3 0 N A S 0 it F11 c W S, N K 1 A 1 0 T H 1,/ 0 N H fr fe H H IV H Al I A A/ R A H I G 61 Al R G 7, A A FII 1 2 E N 0 6' 2 1 0 Al A", Phole Howe 8 n s 8 c 8 R 0 0 2 90 /.0 0.0 0.0 1.0 38.0 8-0 d n e 3 c n R n n 2 IV /.0 0.0 0. 0 /. 0 12.0 11 4. 0.01 a tr t? a c n n n n 2 90 1.0 0.0 0.61 i.0 23.0 V. 4 0.(e, a n w a c n R n Ir 2 90 1.0 0.0 0. 0 /.0Y'2.0 259'5. 0. ' rtVElk'E,'1' t�'UIGrE For' detailed ifIfor'rrlatl'orI of the El11 r'atxnye nlrftber' or for anv ITEff listed, ask ,your, 8ul'lde(' for, EPI-­. 9111 6 of, Font? 6008-93 0 10 20 36) 40 50 60 .;;'0 80 5W 100 _._____.___.__.__.---_r-V_/ I'he rtt.:txl'rtturtt allowable EPI Is 100. They ?ower/'>( t`/he`'/EPI tI`het! store effi'ci'ent the horde- Fk'ESIOEY IAI EI L:"I"k1t''1 F'rl'Fk�f ifl"kJF�fAITL`L. 1�k�AI IIYO S77IFET I TEM HOH& P'AI Ok' I ow E ff r'ciency High E f fic'1 eocy S'IN611 L`I FE' irr3l r'Ir`r7 A+`.1tVLtOWS. . . . . . . . . . . . . . . . . . . . .0ouble t;lear I MSUI A T]ON. . . . . . . . . . . . . . . . . . F'-1 CY +tE'-30 Ceiling f' PraIue. . . . . . . . . 30.Lr FY-0 Fall ,tE' V'dIUe. . . . . . . . . 12. 1 It'-O Floor, Fk PaIUe. . . . . . . . . - AIAl COM)I TlOMEA. . . . . . . . . . . . . 10.0 SEER + SE'E'M'. . . . . . . . . . . . . . . . . . . . . . 11.Gr �'-_,�` __------ IIEA TIO SYS I'DII. . . . . . . . . . . . . . 6.8 iY3PF 12.0 Electr'ic IIS✓F. . . . . . . . . . . . 0 /Ala __--------------------- WA T'ER .___.---___----_------_WATER HEAT R. . . . . . . . . . . . . . . . 0.88 0. 96 Elec'tr.l,c EF. . . . . . . . . . . . . . 0. 1,13 f+ _._.-----__-_ F + r LI.�t;f G,SIS Solar' E'F. . . . . . . . . . . . . . I•____...__..____.------------ 0 THEY __________-0THEY I'EA?VAIES. . . . . . . . . . . ,. . . I cer'tt'ty that these enel,gy saving features r'equir'ed for the r'lovid; E"ner',Yv Code have been installed in this house. 8if ,l der kkv('ess. _ Signa tare Od te. _ Flo(>ida Ener'&T Code for' I3uildl'n�,Y £,'urtstr'cft tx'ort - i S}5'.' t` lor'ida Oe,aar'tstent of Community Affair's i=l. 'Er'1` t:,`ARV``.., DYEfkW)r ti?u,LVL.. F"or detailed informationL of the EPI rating number or for any IfEN listed, 99.�' ,_ ask your ladder for EPI L'x'A Form 600A-93 or Form 6008-9 Cy /0 .ZGy 30 a Cy S C> 60 90 I Cyly -----------------------------------------t`_r The maximum allowable EPI is 10& The lower the EPI the more eff.t"" the how fk'E'SItyE'iV7'IAL E'iVE'F'l,Y F'EfE'F'01j,YANCE' RATIM-4i Sr`-�`EE"T IMY HOMEf!$LULC Low Efficiency H. gh Efficiency SING'L CL A, 06i TI1V7. r ddltYCydI�dS. . . . . . . . . . . . . . . . . . . . o0able Cleat, /-----�----_---_;F._______f IwA&A T IDN. . . . „ . . . . . . . . . . . . . R-10 R 30 Ceiling ft? f"ra 1 ue. . . , , 30.0 r, 0 R-: Aid]] Ffr._f'al ue. . . . . . . . . 11.0 6:'��y_ .___ _.__.__._.__ _.+X,/1 yt r f� 6i'_Ifalue. . , , . Ly. Floor . . • AIR G`ONO T IONE R. . . . . . . . . . . . . 10.0 SEEFd HEA TDW SYSTEM. . . . . . . . . . . . . . HOT, ice`. 0 r kA TER HEATER. . . . . . . . . . . . . . . . (.488 0. a E'1ectrt'c` 70. 93 0.54 (y 96" r r Solar E'F". . . . . . . . . . . . . . OTHER FEAT' VES. . . . . . . . . . . . . . I certify that these energy saving features required for the F'l or da Energy Code have Leen installed x n this house. BONN Address.y Florida Energy Code for Building Construction - 1993 3 L.;-t-ET;>t CARD9 Florida Oepartment of community Affairs .K•:P.'ae.�"�K',�',�•,f:",1�".n"1�",K'.�':'K h':1t',rt',�',K',1t',T1••)t'.�'•�•�t':It'h':at,�'%-,K'•�•r',)Y)l',ft•,k'.�t',W,h'.*.K'-�'`?'-;t'•X"-k'-K•-T'•'.!!'tt'.k'.N•�'�'.±Y.�-h'-K•.K'?-:7�'.K'-:".',�'w Tr.;r,K".P•,}!•7!'.P".K'.!4';!'•�k'-�'-;t. WATER HEAT'1N6,' 9l'=�".�t•.k'.�t•]�',�-,Y•.$',1t',�t',�'.X'.gY,�•�t•:k•,R•,tt',k'�'.%'7!',5�'•�',fi'.�'.K'?�',1�',fit".h"•K',k',f�')!'.'�•.�'-7".�!'-)4•.fl'-!�•.K••7!".K"-X•.!�".K'-�-±!'.f!"w"•.W"•.7�'K'.�!";!'-W.7!'.;�',K-IF•7�•.S�".Y'.l!•.W-W 7�";`•'-X-K'-7!•-T!'.}�'-�' won SASE' zzo AS-BOTIT N(/K OF ,y rYU! f - TOM / TANK MUM iM Ef !'ANIC RATIO IO AM T _....._._.________._-__..___--. 15,212.00 .�l .�tr3�fi..�l`.�� 50 93 1,000 .7 599..J 1.00 J4y.7: 7.:i.. ,k•,yr,N":�',�"•�•�'.�'at'.rt•,n':rt'ar K':�",k':h'ae:k•,%'.�':rt'�,N'.��':R'.)h:1�•.K",f�':K'..rt',7Y,ft•K',h'-�•.�r:rt'ar.Irar,�'.rt at',x-,N'-h'.%'K'.9r.ar.�-n',K'"'-7.•k'.a!•.h•.x'�'.x'%'.�!'a"-'.�.f�',h'-T".'.�!•�!".;t•.�";!'.�•.�w ,K•.pt'.�':�',�!',9Y�",�'.%'.�':ft•,fY.7��,1E'.�"•�'.�",�•�•:1l',�•.�,�':%":k-Y'.%':�'h-,�':�.�",rt•:rt•.K'.�'.)t•,�•.5�';�-�'-k'.w.�•,�",W-W.�"-�'-W..f!'-x'.7�'.X'-�"�'-�'-Y.".K".7�'.�"K'K'.y,•.�'.T�"%'7!'.�'.�'.!".�.�W-7�-�"-�'-�".Y Aa-SV71 t ............ I-1001I;NG HEA TIM-Z +'I0P' wATEA, 1717'Al / C001I7Yl;' HEA!IM Horr pAT rk' rUrAL F'tIIN7's f t•'ttItY7'S Y. F'0I87'S` M POINT3 P lrv'7's r r='iiINTa PollyTS' ry POINTS __.---_ _____________ _____. _-___--____---_--__-_-_ _ ._ � b1r i��� , a r r ;Y. 66 1a4r . 6. 3.0 15272.0 4by3 In,—f wo 3404". OR I �sE' YF Sc "6 3 16 40 65 �6 08 L OpM ;31 CLP 1 0 13 10 L p E S4 13,4 ct '18, ggL (I yo -93 . 76 4 ust 8 81 CO3 w -Wo � 173f GIR A S rr AN Rk 4� 40 PO 4, AL GLASS .A c TOR oAril at 01"A L wpf�,I 00f, At.,, A 191 "ON I e,Et' G.nEA 00 VE, Afk- 6- YF 0 —"5 p t mie A 6, woOd Fj 00's AcLl 19. 1 ALL 6 4 05,9 wood - 0 Adi 169J�i 255� Ad] 30A 105 0 Ig.3 19,4 19,0 Ext older 1933�2 der AS - .0 W 1 e 16 Wow-Ufa uA AdJa • ,,OORI Sjb 100,0 pr9ct Rsd 2013 w. "Of TRW " NF L p 15 Kr cA x V) PO I -rA L 0 AT f p --- wo WAZT.6INP 4 SYST p g LT TVAL .--71: ?.T7.5uiarlvre OUq.. r Ce)iIIt a filltte:munl a t : . MR,-II r, . , .. . . 602. 1 C8S R-:i both Ccurtrttvrt c&il 7 op Si`iCir3l s l,k, 1 t -------------------- ,yl,x',x',x,x•*.x.�Y.x,)Y.x.N".x.x x,x.*,x".r, ,x.x,x,x•>F.x'.x',x.x.x.x x',x',x,x'X.x. .x.x.x.x'f!w.)! <'1j tb EA1 c°A I CUL A 11ONS .x',x-.x'x'.�.x":x,�,�,x•.x",x".x�,x".x"�.x",x"•�.x"x",x",x".x",x",�.x',x`.x",�r,x-.x�.x",x'.x',x�.x'.x".x�.�.�r.x".x".x".x-.x'.x'.x.x-.r.'.�r.ar.x".x"-x'.x"�".x".rt".x-w,�.x",x�.x'.r.'.w.r.".;r�r.x'.x":�.x".r.".x':�'.x'.x HA SE AS HUI f' G1 ASS- rr•>11.1 y(, 9 (,)t�/rc Jr�•1 r(� ` • r/rL <•�I I•<•r y(� u:•A X 3PH ,k 30F P011V73 V7 F l L.tY A7 k l:'A �K fJ+,7`/"t C �-� P V.(t T C'..l' J� TWE!"L. J L.' V7 k L l.�tY AREA A _FV_ 9 5.4 0 65.8 6'4.;;'4. 081 CI iY tV �.'16.4 38.3 i'i ;'16. 1 o8l. CC R tY 42.01 36. s S's 14rs'f`,•0 1 C11fs l C1RtV 1611.611 `&`.�' 041. ` E 114.20 66.8 ;'.514.4 f 081 Cl F' 1 C11lsl C1 Al E 2. .611 5' 8.0611 65.8 526.4 / 081 Cllr' S S.0 66.2 . .;:,4 3,9 1. ,> Fit 2515.40 65.S 94.3.;;'.3 ,/ 081 C1 IE' Fit 1 3.0 ;'S 1306 4.2 1 081 C;I R Fit 26.4 :;'2 / 1;131 Cl . 94 4 4.;:,1.2 1 081 C/A, Fit 36.0 'S'. • . 92 262'5..1 ---------------- 15 x CChVt:11. F'100A, i TOTAL, GIASS A0J. x G1 ASS - AOJ GIA33 / 6,'!ASS ARIFA ARLEA FACTOR C-''CTItV7':5` POINTS 1' F'ohvf;S` 15.._ 2, ''21.611611_ 516.0611 'S'7 ..s'..i, 952. tYC11tY WA IIS____._____.___. F... 25,.,..,. .. .Kt 2664.2S�' �� � 1s f Ext- ?Vvr'tttFiti''I31uck In 22. 0 4'16'64.2 16 4 i b. , A dj 205. 9 . . 144. 1 j' Adj Wood F-ralne 71.t% 26115. 9 . , 611 144. ,1 WORS_____._.__.______.__ Ext 20.8 6. T 126', 9 f Ext Ftlboe,t 20.1 p. 10 126. 1 A(YJ 19. 1 2.4 45.u f A(��i Wood 1, . r" 2.4611 4.5.15 Cf .I l I M16W.-_ UA 111611.611 .6 966.6 / (aider AI..I..ic 0. 0 1683.6, .66, i611G% '.G�, 1 Uride r Attic. _ l i'. 611 1611.5.0 1. 1611 11.5. 5 SIF 1Q8.0 ..,ti;'„611 '. 26.0 / Slab--of?-Ordde . 611 -4t'.2611 816 A'sd 1611611.0 4.611 +'99.0 / 4'S C1 Fitl}od Adjdueat 00.0 41 461.61, rt IV-II TAIAT/ON--------"~~ 1 2;'21.6) 8. 0 21 Cid.611 / F'racl•'ice 1#2 2;'21. 611 8 0611 2l;:"6 6.0 f'07'Al_3UKN£ k'1 PCII)W f 44, 5-80.45f 4=,>, :',�5.08 --------------------- TOTAI x S1'S1'E'itil CCJf}I17VC' / TOTAI K CAF' :K 0,YC1' ,y S1'37'I:H x ClE'RUT - COOZIrVC' SUN F'l AW1 ! F'CII rY!S f CCIttiIF'CItV lF'A l I U t`'CU1. T HUI 1' HUI T POI tV T S y44, .580.4`j���. 3,1 111;,45,'4. 1 , f 49, ll65. 08 1.611611 1.611x'6+ 310 1.00611 16,5611 r'.6118 ION 1',tk f4 f4 L,. Ut H:;-<^"�.". .ftt� t")Tk j, ..w-^".'""vy.t ,FIL opei TION SEC ALL = Cuff _. - —~ GF, `f C' i. �1.1 , 600 f 0 ~ 1 #�f Kjltttf#2 i?C udes ~~ fL'- t �fJ r v* r i?ti _ C7 ? iaL _ - _ ~tj.ipF t) it t6" w en core netedr lott;#17 r c2 `7-0 Ied THE f,I Red �� _"-~~ " der, bqry NI ed. Xeu a 1 - ani 5l fir, J _• . 5u{.. Nerie 1Z _ t�f' f,I� 4ttjr: i<5 carr s ~ ~ 7a1 _.w to �.f _ - w 60. {25 ~ y t r yr?5, Vii {rte �Qsf� d. _.. ~� � u. r.s `` F:yrtt{.«1 tions, vr" � ~. _ tQ�w� !#tus� be "I __ 06 i Gain{& _ ..__ ` z .x #r sf _- __.- " Ur r?u ..._._ • -�t. �r��]`, .. #? l�rlr,�rr2 -_.~""_-� �u{? air y to Ius r/ Ui;ped wit I 6 6 and On Exhaust � �u��,usi'zvr der si re{? utel _ �}ri IV zth t t Tar1Ces" ~-' G'ede r#'rt• � - rj :a _ ~_ -. . al !11ements - t r be {a'f`f`�1rrk' f;'kT��C �kt���' V I? "" ~ comply �?r��rr]'eat �.���1t, �{.ftyztlG�" I wed- Ws ,,der ,EtaOVZ to hemi- trap _._.." muse f?dY 0olsuse. hayr In ~y rtcf I .13te'c rt!#2 'r.xal .P lta# {tt tt it? _w y - _ 11:Qd �.0 rajJ" 1 7ttiCiX ft la rU {?{ • ~_x no ;��fhr??{#l o gas ric ;2cY w-"-~ str.i�•" to SpgS t be f, r r PSIG flow Pius so 7 " 1 loris {T {• atz -• - rtlEc f2 r1 1�77 ` sJ tai•`}'t G5 _ - w•f){.1 t. ✓ t ftartttsds Y Cir r?`% + ,,over ~". I duc,��s� i l be #tt ca rt ac'c:�{ rtcin c 61(it _ t. 1 tg+{`5 a,f7. u{?c ' £>• jai 1 art Ulm �'d ark{? 10. LL�lt2 .{ttf8am �#.ft?less tri Air u{ 5eG f.. t� 1 c1 .,,stems 51. le �5� art attics - '' be i r15 i;a I 1 _ t me n t 0 f etmix uo i tY SN.- 3 i 37 F'OPH 600A­93 FIA?1DA EiVk�-­A,4�,y C"01,M" FOR 8UI10j'jVt-�' Co1vS7'pUC7'j6,,iV 1"resi('e"ntidl AlhOle gilildint`f lyet'hod A MANE: Plan 9 2,;;'21 Sq. F't*. 18U1jDEAI_: J Crosby and coopdtry ANZ) A470,9158S: 1PON'[17 TING /cr..1"i'l, Atlantic Rea l2MVE: fV0. tVO. L Me* coostru'ption Or additioni. lVev %vr;sE;r ac t io 0 9 2. Silq�wle F-,- iJ 2' S"n (Jet8Ched 0-r' �1111t�ifdfflily 3ttdCfie(j y 3. If Hultifallvily-No., of units S. 0 4. If A1,vjtjfdtjrjIy, 'S t.h's a wol'st Cds,,-" (YeSINO) 4. S. CO8d1tf01?ed floor area (sq. ft.) 2172L 610 6. /:Iredbmi.qdnt' &d6,e o.V&r-hdng (rt.. ) 6. i. 361, /Jorch overhang leogt-h (ft. ) 6'.f-;t6' 6,ldss ared and tyl d. Clear 67dss Single ✓Odne 004itle b. Tint, fillp 01, sold[, S4,,j._e&n 61'sq 3 16 00s 9 8b. L 0.t9t,S aft Floor type and insuldtfon: d. ,`1`Idb on gradevalue, pe(_it#etej, 5'a.A)=- o.oo ft- b. Wood, rafsed (R--i/alae, area t ;­. /­­­ ,V. c- 1,,'. 100. 00 sqfl "-'Vet W811 t"Vl-le area and jn,F�ijldtion: d. EXtej'foj'. I. Coner,ete (jjjSjjjat*ion !_4/d a�e� , b., 4dideeot: 2. Wood fe,d(Ile (1, Rz22-00, ;,"66*4.2os(1ft I nsuldtiOn R­vdlue) Ob 2 1/. (gt """eiling tYPe 81'&T and INSUldtion: 26,,,5. ;,,0s'qft d. Under &tt,jC (j'jjSUjjt-jon 10_5.to of 8. Under at-tic (Tn,,UJdtiOR rLsr_va'1l 12�Air sy.5la RZ 30.00 6+6eSqft, tetras a- trvcts 0'n,5uldt10n A IM"dtfon) 12a. 6,6, lent;Ullti' t3"Cooling system i3. Type. Cetj-d , J A/C SEER.- Hed I 15.Hot water system. L5. 1, HSPF: ,�q:w. Electric 16.Hot Aldt*er 6T: 0. Heat t"'- Infiltf'dtiOn A"I'detice." 1, 2 or 3 12 18.Hf.1,4C Credits (Cl--Ceillng Fdn, Cle-cf,oss AIF-Al/tole hotjs4., ran, yS_Attic f,a(Ijant bd"'ief', A/2� HIVI tf20(16 (1pust rjvt, &,yet.,ed 106) /rOj' Ot-5) 99- Total 4s-sljijt points 46 66 b. ?'otal 8ase points ---------- --------- I* ce-"tifv thwIt' the ivIdns and fievlev 0 1, 1he pldrrs d1to, specificat,,'oas s'"cif"c3t.'Ons L'vvef'ed 0 this cdlf,'U- covered .6,y this Cd]Ca''d! ladicdts lation are iA Compliance With the Florida F c1d Eoerqy 6efo�,e ConSt.f, 'AIVuG" WERS, INQ act-ion is compl,eZed PA1014AIE0 this buflclll�g will, be e,�aspecled for 0A Tk­ coxoliance it) accordance wilb Sect,iaa __...�.�.��t��(�6�I�fittt�;--fL-f}�4f��--�2-2�-- i s.�..�. :��cr� i="..�`. I hereb y certify that this building is in colippliance with the Florida Eaerqry 04 TE*: of j1,Fr f;Ciii <;� r,., Ff 1 Gx 'rVG`l ti r rrzlr.: F •.•+•. ``. Res fe rr�..x-� ` z:fJL'r;.. l wbolea F rS3 L ,IrVG+` COJY"5'f,4'lIG'r .tfry Srv. f l 'ri l3drx'Ix`rt r c'r ,{.frfr.rJTlarTt" Sq, Ft-. l7�l�fJjr, `r'>:. /r�r ,rFrJLf .%'7 r�f;' i,r`L)S'�>(/ rTCr' i.•`tlN1 Lr rvvr•`rvr y /Lt,4r`fG�. r��'l ,/rc,1.iT�f.�tJ'r=• • T, I ,L'r1'"7rL rv.1 f.�'I YJN .. C+ f✓r T i�' ,'/...,. r r 2rtyl 1cd/ c '61 ri�rJTxl C{ rt„ S`x'rJcxflL/Ect✓rrrF4�.'.':;/"nrL'xYd'rrlvL,y l';i" CA', 4. eT x1 • is a rvvr'.st" "_... flool" b- �tr'f'C1rUJ#1:'r ' �r,�,�;Y �s -^-----...,.. ... Jrd rJ�/.' F`r5'f�•'�+ G+i/aw'r`,�t1s'{i�•,'qir' , t" ,c " ,J •--,....__.._ or•r:+f, rx e r',i�f rrc? " S. /'`h"a", /;"Iris's,'•.."•.• �,, Fx'IrJi rsr' svl '{ �x"rryle: rre C%uul r Floor" t tl{�� sc� 'eeari its" �:" 'p -.,.. l& rt'''a'iT� a- oo, , e a"r x' t'trJ. asr rc $Ira.CtCs �d '" akrrxL tc , v 'I drh r e>s r'x'/nom r' "E L,.lye f:. { tea'I dfi `, <,r ,.... A a r a rtrJ" rlsdrld :: �rvn: �'�'.rF f " " f C`f ri �IJL rl7rx G4 dI`G•-x" r.rsUf�'LrrJTrCr'Tt1,f{rr``4 •...` a 1rTr x/fJrrs`:.x'LyxIrrrrSIfFhi,cs_'l00 rr{a u ` a �"r1fr are. aldfi a xLr� 1L 4, 2 +fF;ri/2?%`,rsrldfrrt l+t>T1fi , rdfes.4itrI' Llrsdrla J Ir'r't J _rt cz" od,rL c., {, ., 'i;E.*JJTS r�' /1r.7"rF ,„ t r r LT,:7.GJLi,G✓'Cri��. J�trrl.i'drr'"ct' ytr.00Gr" s,€rs��rn � 7 3'. L3Lll t'rt" l L�rt 104G'cd I jon .�' � 6'. CtC• 13- t irG`r✓iJcr' *a t er st?:ti / „r11f)I` �tie12"fir' `{ /'5 . f a ,y5 '�, "iGi _• •t.._ ""rye �' 1 L:: 17 Gth',� fT+wrt+x' ' �r 'a'1` FF'E>r,'C"It%�r,i�. �,•F..y r•.re>c:`z""r ----.__...., S"J`7rP:`�f'` ( � T Gt`. flf +VJrtL;+lam frL+uss .5r r is'r�, Ck' G'r'uss rr1�r 1�1.i'rtr ,ri'L' 1 I S-'. rl eulsif, J' ..,{drl 'r' r+rJ`) r9r""�'}'L:` r'i�cr`x�'rJc _ 4s-81 - LI 7t)tal { rxlt' poi res {tt„ Points 46 re c'i1� zvrT., a thectl��rr� i�rJc� w__....w _ _-- --__ _w l+(�`?r' }r� /iS "115 t' rl ��t 1L#d r,•tT` yi.r . «...._ _ w F l yr o• , L'rr-• { b'v c'r'y cT � r rrs��t iJu`« tl.T'<1 riL:'.r.; dar.r 'Ir fie. Filer. . .. .... �+ n,/�f ' L/rx's' L.`a�'It;'dll�'��x`LlrT ' A MMEERS �N�. { C`tJlLd+l x' iic+�; trJril'L'cd � � f�`L1CJ`,�•`, t4+.t G"IJ r,1J�' rr`•.(rJr'x'ti`rd �t^a' f$rs`L•"JC•ra�JiT�'Gi ra i:, p f3E:`rClr`�` �: 't7 BE DLVD. f �/Txs �'ClfJ,ti'�!"drt;`2'xC>rT 0 f. ,.4 z,f. rdrx'I ra'z rJ r . , r T s e'ixi# , r L'a Jr# >Irl {T *11.J be [rJ. �r6L'G 5 T fJe7r' , — — / 5 s.: <;r i�'L~L`c>{`rx;'rrc' auI Lir ,t✓ 4,t,�".x' � Crt�3 F•..5`.: G ,r x'rr L`L'rrJJ � �'fti�� �"fTx's ltdrr'IcrrrrrY Ix' rrL, d x'tlJ the Ivrx'rr �.. is rrergv OA 0",, L .. TREE REMOVAL APPLICATION SECTION A - APPLICATIONS MUST BE RECEIVED BY CLOSE OF BUSINESS TUESDAY BEFORE THE MEETING! 1 . Larry And Michelle Walshaw 2139 Seminole Rd . Property Owner ' s Name Adaress Telephone 1. Lot 11 Ocean Breeze Drive Location of Tree Removal/Site Alteration SECTION B - (To be completed by applicants whose property is zoned residential , includes an existing dwelling, and which is not presently owner-occupied) 1 . What changes are proposed to the above specified site? New Building ( Residence ) 7 . What is the purpose of these proposed changes? New Residence 3 . Specify trees proposed for removal as follows: Tree Count Species Size(DBH x HGT) --Condition 2 Palm 1C 12" & 1C 8" Poor, Fair 3 Bay 1 ea . 8" , 5" , 4" Thin 26 oak 1@ 18" , 2@12" , 2011 " , Fair oak 2010" , 209" , 708" , 507' , Fair • oak 1 0 6" and 40 5" Fair 4 . Will these trees be relocated on the same property? No 5 . If not, will replacement trees be planted? YES 6 . Specify proposed replacement trees as follows : Plans not completed yet . Tree 'Count Species Size(DBH x HGT) 7 . Attacn site pian. (Note: All trees proposed for rawva be marked on site by red tape or flagging) , o 1994 Building and Zoning SECTION B - (All other Applicants) 1 . Property Zoning: 2 . Submit the following: SITE PLAN/TREE SURVEY indicating: a) Site topography, existing and proposed grades b) Existing and proposed structures c) Location of all trees w/DBH of six inches or more d) Tree species and sizes e) Trees to be removed should be clearly marked f ) Trees to be relocated should be clearly marked g) Location of any proposed replacement trees . h) Identify trees of special or unique characteristic i ) Idenify trees within 10 feet of construction areas j) Show location and type of tree protective barriers k) Location of utilities, accesses and easements 1 ) Location of vehicle travel corridors m) Location of commercial sprinkler/irrigation systems n) Landscape maintenance plan (commercial only) o) Staging areas for equipment and material storage 3 . All trees identified for removal must be marked on site by r&d flagging or tape. SECTION C I agree to comply with the rules and practices established in Chapter 23, rti.cte II of the Code of ordinances of Atlantic Beach. owners Signature Date CI jY ,USE ONLY Applicant has complied with all provisions of Chapter 23 and requirements of tie Treo Con$erva. tio $4�` ' � "All trees to rz ;;ti :�e barricaded >� am inimum cf 5 ft. frcrn the trunk of each Date tree. Barricades met be installed BEFORE Tree Conservation Board De ignee M014se- f constru Place during NOTE: "Tree Protection for Builders and Developers" is available at City Hall or from the Division of Forestry, 8719 West Beaver Street, Jacksonville, FL 32220 . (781-1434) AAAP SHOWING BOUNDARY SURVEY OF LOT II, REVISED PLAT OF OCEAN BREEZE, i ��S To Be AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, jee OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: LARRY E.WALSHAW AND MICHELE D. WALSHAW, COMMONWEALTH LAND TITLE INSURANCE CO. SUNBANK /NORTH FLORIDA,A NATIONAL ASSOCIATION, LOT I OCEAN BREEZE DRIVE tit k t N89•-43'-35"E 60.00' I '2 t e'KW;044sa CAF (PRIVATE ROAD 1 30'EASEMENT FOR INGRESS 6 EGRESS DRAINAGE AND UTLME5 C MiALT PAVING Is- - j nPE CUPS AND UTTER 40.00' 70 JX.Ati t—' Q x(10.7 1 (10.71 O 12'►Al l� iR ..... V � 12A sRl. N J s-Pv x (8.6) D'SAY +S�'�AVE S-SAY A-SAY • .__ES f0•�T4 NO. Is'O,X 0 t� 16 9-OAK 0 Q to L I I s-w -Out O 00 y- ¢ 17 oQox � K LOT 10 W 0 K \ OAK e- K p I�+O�IIQlo t ell o a (2 Path '1-, 8 x(10.6 1 a x 4 A-OOAAK 0 !-OAK (n IO.OAK to W . !t — to Mtn •3 3 OAK 8 OAK--*O N ) t0.OAK .� J to ` E S-OAK s- �. / i O e Tree z .7 ''� N Removal AP ro6red as Noted 0 I o fe-aw( 8Y W z x 7.71 S � ' � 1 Date /!� I I� r OAA Ix OAK 20 eni SII trees to remain must be barricades [��TOt t(Os t o °o I2-0I1K a minimum of 5 tt. from the trunk of each o r oAx tree. Barricades m(;;t be installed BEFORE r OAK 6'84"0 O 6-(� site ulearin t ss► x10*OAK 41"OAK o 8 and remain in place during 00 10- OAK r OIK O OAK x(7,9) ��C phaScS (1f^on$truction." r W 60.00' f 9.6 J � S89•-43'-35"W rON t Ab/6,0,4 Mot MAP SHOWING BOUNDARY SURVEY OF LOT II, REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: LARRY E.WALSHAW AND MICHELE D. WALSHAW, COMMONWEALTH LAND TITLE INSURANCE CO. SUNBANK /NORTH FLORIDA,A NATIONAL ASSOCIATION, LOT I OCEAN BREEZE DRIVE N89°-43'-35"E 60.00' ( '2 Le 1046 s�P PRIVATE ROAD ) 30'EASEMENT FOR INGRESS 8 EGRESS DRAINAGE AND UTILITIES p A PHALT PAVING B"CONC. q (""PE CI"P4 AND 4UT'TER 40.00• of i 7A'J.EA� q - O / X(10.71 (10.7) pppppp(((��� IZ'PALM iZ O /M10 9l 1 O 12.5 SJLL. cJ 00i 8"P X (8.6) � I X(T.I 1 8^BAY 0 p BAY V�%PE� 0 4^SAY x.,314 6 IB"OAK 0 I OAK O M 09^ Q M Lcr 11 B^OAK .OAK O I 00 p^ 0 I7-OAXK LOT 10 m o0 K \ p^OAK p" K O 7^OAK O O ct b l2 PAS ell X(10.6) k •4 B"OAK � 8'OAK 0 1 9 OAK In 10^OAK M LI L0 3 OAK SOAK`y0 N 0'OAK L1J 10 10^ p'OAK e. °'o I N PIPE oft 00 O e•OAK DOo r OAK 0 _z °' to 2 0 0 Is,OAK W z I x( 7.71 20'eitt. c r OAK 012"OAK 0 0 Ir OAK of 70i(102 1 0 8'OAK I r 6"441,0 o e-� l 8.3) X 0 10.OAK 0 r OAK 0 00 10- p� '�� O qo 6"OAK X(79t s•OAK 60.00' S89°-43'-35"W Lol�� A'b �hPE MAP SHOWING BOUNDARY SURVEY OF LOT 11, REVISED PLAT OF OCEAN BREEZE, AS RECORDED IN PLAT BOOK 46, PAGES 51 AND 51A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: LARRY E.WALSHAW AND MICHELE D. WALSHAW, COMMONWEALTH LAND TITLE INSURANCE CO. SUNBANK /NORTH FLORIDA,A NATIONAL ASSOCIATION, LOT I OCEAN BREEZE DRIVE t11X Fo• (�12 LB 1046 PRIVATE`AP i PRIVATE ROAD ) N899-43'-35"E 60.00' 30'EASEMENT FOR INGRESS 6 EGRESS DRAINAGE AND UTILMES o A PHALT PAVING Is"CONC. b FO r MPQ C1IP6 AND GUTTER 40.00' 7A'J EA' R Ox(10.7) (10.7) 2.0 O /� 1 1r PALM v � � 0 1eltL!2 r- — e"PALM x (8.6) X17.1! 5BAY 1 DAY 00 4"SAY �•4b14 IA"OAK O 1 9-00 o D � o M LOT 11 s-OAK c I -Mimic — 0O 5-00 '.°'0K LOT 10 0 OAK cr- I 00 -r OAK \ m O y^OAK Cb 7-OAK SO Li o a 12 PAL)" 0 $ x 110.61 Ioa 1 e•OAK 0 I i'OAK 00 If) (6.4 1 10"OAK fn {i•I coIr OAK S"OAK y N 3 1r OAK o I IT OAK e• (p 111 in 1e" s"OAK e^OAK J N PIPE a OAK e-OAK O O iD 7'OAK N z II c OIS'OMK 0 X(7.7) W Z V7 I I 1r OAK 7.OAK �- — -- —4- -- 20 esu. stow r OAKIz"OAK 1fT; O OO 12'OAK 70�l 102 1 O Ir OAK O I 71 OAK e"eAYO O S-OAK ( 8.3) O x lo-oA►c r OAK 00 Io-OAK 9'OAic % r OAK x 17,9 1 ° gr OAK OAX 60.00' o (9.6J �i�Aw' S89'-43'-35"W AniQa Pipe STONE, JOCA i June 15, 1994 MAHONEY Consulting Engineers,Inc. Mr. Don Ford Chief Building Inspector City of Atlantic Beach Atlantic Beach, FL Re: Mr. and Mrs. Larry Walshaw Lot 11, Ocean Breeze Dr. , Atlantic Beach Wind Load Analysis SJM #1545 Dear Mr. Ford: We have reviewed the plans for the above referenced project and the plans are meeting the code requirements for wind loads. Please find the attached calculations for footing design, overturning movement, uplift forces, and the exterior wall design. If you have any questions, please call me at 904/264-1377 . Sincerely, STONE, JOCA & MAHONEY, INC. John J. Mahoney, P. Vice President J DV JJM/gi � 1994 Attachments Building and Zoning Foxwood Center • Suite D • 1730 Kingsley Avenue Orange Parl<, Florida 32073 • (904) 264-1377 • Fax (904) 278-8469 Loencts a c-hn� c�nno s-�osn'Qs De.,:nc1 ids'- >;'_oo-� = 15 Ps� _ ►5 >c 352 _ 285 P,Q� Lc,n dtorn [.Oq 1 15 = 2-2 x 5-6 - 12.32 �.. n�'s-�►ice 6e-�,.p� LvcT� .�.ea�-+ t`''� cilca I!s . U vie Lood 12001 L.o1p( e r -��rncd.a�e W�si e load : 4o x, Tbfa 1 I c:(cL5 a C (L. L Tf DL) /�s��.�e scr ►`rt Ccs c�' 04 ,-&1,J ^ 15�o ps �" APPRC�W � j Vi f MY OF ATLANTf,- .29 4 2 VV 15-00 JUN 161994 P st O r cl e 2 l� cl E1 7-P 7", P; 1 51994 Buildi,ig c) 144- 01r29/{��r r r'nC� C1Ue 40 l-vi`v a � 5 1 (�cc�6pP ) 38' Iv�hd sr ce p�e-acq Load- .- 1� h o-s i i n R oo in rr)x'04 GZ`{ ppp9/) We,q h1= o4- w0 1 I s = 22 x 5� = 1296 P-1 0 p �=�,p-�,'r� 150 K 2 x Ta-tz� ► D�ctd 1 cads = 1 4 I.�i nd -fom ce o ctl 315 ps upI"-�Hrj jos1ce = (W) 35 x 3v x 30 3� 2 +I� P� Dead lOQds Qc ►meq dc,coq _ 14g6 L3J ' �zu c-ta�i Chi ��C� � _ � �f-g� � �• S / 14 I C4 dYe�tV9li�i�'tC� /YtC�f��� C�Ue 4-0 C---P, Gl) U 35 x 3o x 2 rn on-�er D-ee?d i d s I� Bb x' 3g 1 [f(z8 a 0V n i`11� m o o-) � C� D�sr5 r) EX J�� r`vr Iia i I s K�c 1c,�"� Cc�nr7 lai'►��d �exvre { cr"a I 1 c% C4 Cz2k) Qsf e c 25 fc)3,(e:r4 Cor)Cr�2`F-e ® 24"oC) k = IO -�� Pnw - (32) (5) �Phs Pew �ei r� Cea( 2 fir O C P,Lo 5 -4-6S .PSs P,Q P 2 T C6) i L( = 1 4 f) -4 L R OC4 NP-0 cl Loc;d = 12cv L►` e I t>oci _ 2c> 6s / f+2 it-)4"rr e of n-tr 0091 D L = 15,t In.,-S / p� Ir)4 sf rr,ec, a 4e !rx>sl LL = v .P 46s 2 D P G d Lcc,d cl c.,e 4c, Se c r1c� s X91 c 1 = ► ► )c 616 l7�'s 1 race 6e+weerl Pee b = I •P bs/ 3 g ) + 3s 6f 6 ) lisp P � � L = 20 C 3 g \ 1-40 (�o 2 ) " P 1. 4 (If S-6) { ) _ 359 2 p..P�. CITY OF ATLANTIC BEACH N° 12576 FLORIDA 7r— 7 19 NAME ADDRESS CITY ' ^-�' c".Cdj� L -7 as ^ 1 /96 10 S7 When Signed, Dated and Numbered, This Becomes an CQ L*g M $30.00 74 MAKE CHECKS PAYABLE TO Received Pe MEMS 7/07/94 Ol Rcpt: 0064746 9'c94 CITY OF ATLANTIC BEACH, FLORIDA TREASURER ' �l' Vit. ,. t4,.a• �,., ?k�tif FkE--z;EHVICE DIVISION JACKSONVILLE: ELECTRIC AUTHORITY 233 WEST DUVAL STREET JACK50NV1LLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTIONS) HAVE BEEN MADE AND ARE SATISFACTORY : ------------ ----------------------- --------------------- o) ----------------------= -- ------------ Enclosed are the blue copies of the permits. SINCERELY, 1 BUILDING INSPECTION DIVISION cc : FILE CITY OF ATLANTIC BEACH, FLORIDA ( - APPLICATION FOR ELECTRICAL PERMIT 10 THE CIIIEF ELECTRICAL INSPECTOR: DATE: 11GZL IMPORTANT NOIICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING 711E WORK AS DESCRIBED IN TIIE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WIT11 TIIE ATTACIIED PLANS AND SPECIFICATIONS WI II('11 ARE A PART IIEREOF, AND IN ACCORDANCE WITII THE ELECTRICAL REGULATIONS, CODES AND CITY OF AT I M TIC RF.ACII ORDINANCES. ELECTRICAL FIRM: TER LECTRICIAJOURNEYMAN NAME ADDRESS: FD BOX •LDG.SIZ BETWEEN: RES. APT.1 1 COMM.( 1 PUBLIC 1 1 INDUS.1 I NEW( T OLD I i REW.1 1 ADDITION I I TRAILER 1 1 TEMP.( I SIGNS 1 1 $O.FT. SERVICE: NEW i i INCREASE 1 I'll REPAIR 1 1 FEE CONDUCTOR SIZE AMPS COPPER 1 1 ALUM. SWITCH OR BREAKE_. AMPS_ �-►H _W �OLt _ _RACEWAY. _ EXIST.SERV.SIZE AMPS _PH 1 W VOLT RACEWAY FEEDERS NO. SIZE _J NO. SIZE NO. SIZE LIGIIIING OUTLETS, I--- _CONCEALE_D _OPEN TOTAL RECEPTACLES _ _ CONCEALED 1 _O_PEN _ TOTAL 030A 0 _31-100-Am" ,) SWITCHES INCANDESCENT FLUORESCENT&M.V. -- FIXED----- o.loo ►[._ -ov[II- _ ----- - ArtuANCES _ jBELLTRANSF. AIR H.P.RATING H.P.RATING >-- CONDI IONING - COMP—MOILOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 1 1 :OYES MOTORS N.P. VOLTAGE PHS NO. 1 N.P. VOLTAGE PNS MISCELLANEOUS TRANSFORMERS: UNDER 6W V. OVER IN V. NO. KVA NO. K_VA NO.NEON TRANSF. NO. VA. MA. MOTOR SIZE SWITCH FLASHER EACH SIGN FORWARDED TOTAL FEES (J PSR-3844 8526 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH ---- PERMIT INFORMATION ------ -------- LOCATION INFORMATION --- . ermit Number: 8526 kddress : 90 OCEAN BREEZE DRIVE Permit Type: PLUMBING ATLANTIC BEACH , FLORIDA 32233 -lass of Work: NEW ---------- LEGAL DESCRIPTION ----------- Constr . Type: WOOD FRAME -Iot * Block , Section: Proposed Use: SINGLE FAMILY Township: RNG : Dwellinas : 1 Code : 0 "ubdivision: OCEAN BREEZE 4'stimated Value: $0 .00 Improv. Cost : $0 . 00 Total Fees : $64 . 00 Amount Paid : $64. 00 Pay. "24/94 ,ABING IN NEW SINGLE FAMILY RESIDENCE OWNER WC)RMATION ---- APPLICATION FEES ----- PERMIT t:AA ()n T7 ATTLIANT LQ BEACH F L OR I DA SEWER IMPACT FEE 80 .00 ('904)744-6604 WATER-, METER/TAP $0 .00 RADON GAS-H.R. S . 50 .00 ------- CONTRACTOR INFORMATTON RADON CAB 5% $0 .00 Name : C.W. WQOD PLUMBIN CAPITAL IMPROVE. 50 . 00 ,Iddress : 1328 ROMNEY STREET SEWER TAP 80 . 00 VACKSONVILLE . FL 32211 CROSS CONNECTION 50 ,00 -76? 1"10 . 00 r Frr)2 S' Type : 4 SEC H IMPACT FEE 11 CONST . SURCHARGE 50 .00 SCHARG,E/ATL--:,,BCH . 1-10 .00 NOTES: NOTICE —ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS." ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. EN zzZ—__ ATLANTIC BEACH BUILDING R�TM�:;p oviwvow R.A.W 14 By: x DatCKSe: 6/24194 01 ReRcpt: 006M5 CHE936s.) IW .i . "•\ . � .l ill.�,:1:'� '1.•i' //��'/��%►`� ., ' :.1•..' rt i t1TLANTIC BEACH CITY 01 '._ '•: APPLICATION. FO PLUMBING PERMIT :JOB LOCATION 1y ! PLUMBING CONTRACTOR o`� :LICENSE NUMBERS '• '? � ,�(�� � .�• •.. •'' } . • •�,: ;lit',j;�� , OWNER ' ,: BUILDING CONTRACTOR •I ,,. •may •.. 1,:,. .,..; TXPL OF BUILDING �l "lam/( • Y ?c;= ,• •j'i"iil; ' SINKS :, $110tlIJRS •,.;?;;:�,��;.;'. ' LAVATORY .;'l ' :il:�,:�1•i' ' . • ' �.• • �_WAl'1;R 11);AT1rRS .�:;..�s ,l;/ BAT' 11 TUBS DISHWASHERS . URINALS DISPOSALS ' ;'��';�:`•` CLOSETS ;;:. :•:: I•:'"i •r' ' �WASIIING MACIIINEI �'• ' „'; ��('' FLOOR •DRAINS ,: ` OTHER •� ••�.�'�'" ' • ..' �-�•' ,�"1Til 'TOTAL FIXTURE- COUNT �`•!�:;� :: .;;::' :�;'•:' ;s�.i:7: , • ` ;'•; •j.i' �'!'"rte' • 7,,,1.1. tillr t4�1� '••'•' ' , ••7'.''' • • •l',;•j,�,•�'I '. It INSTALLATION OF PLUMBING AND FLCTUI�S MUST' BE IN ACCORDANCE' 141T1i MOST RECENTIrDITION OF THE SOUTIILRN ,STANDARD PLUMBING COD1; .:of- ' •i' 'i;!' is •�,• '.,.. ..1:.;���.�(:�: 1, ;. ,•f1 (( •! � ', • y,.1'•'.l CITY OF ATLANTIC BEACH, FLORIDA Arn ��•��r APPLICATION FOR ELECTRICAL FERMIT TO 111E CHIEF ELECTRICAL INSPECTOR: DATE: IMPOR I AN T NO I ICE: IN CONSIDERATION Of PERMIT GIVEN FOR DOING TIIE WORK AS DESCRIBED IN TILE FOLLOWING, WE IIERFBY AGRFE 10 PERFORM SAID WORK IN ACCORDANCE W1111 TIIE ATTACIIED PLANS AND SPECIFICATIONS, 1NIIICII ARE A PART IIEREOf, AND IN ACCORDANCE WITII TIIE ELECTRICAL REGULATIONS,CODES AND CITY OF All AIITIC RFACII ORDINANCES. LECTRI AL FIRM: MANE ELEC�RICIA�SIti ATURR �IQUEIMUmm - - � �A d [ NAME ADDNESS: RFb BOX BLDG.S E BETWEEN: RES.1 1 APT.1 1 COMM.1 1 PUBLIC 1 1 INDUS.1 1 NEW 1 T OLD 1 i NEW.1 1 ADDITION 1 1 TRAILER 1 1 TEMP.to SIGNS ( 1 $O.FT. SERVICE: NEW 1 1 INCREASE 1 1 REPAIR 1 1 FEE CONDUCTOR SIZE _ AMPS COPPER 00' ALUM.I 1 SWITCH OR BREAKER -d—AMPS PH VOLT _ -RACEWAY EXIST.SERV.SIZE _ AMPS_ PH W –T_ VOLT _ RACEWAY FEEDERS NO. SIZE �1ND. SIZE _ 1NO. SIZE LIG111ING OUILEIS CONCEALED OPEN TOTAL RECEPTACLES -- CONCEALED _ _OVEN _ TOTAL — - --- O!O_AMP• SWIICHE9.--- -- ._-- ---- -���_�.------ — INCANDESCENT FLUORESCENT b M..V. _ -fiXED` ` T­a oioo i,M�� vcw ArrLIANCES _ _ _ _ _ BELL TRANSF. AIR H.P.RATING H.P.RAI ING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KWHEAT 9-1 OYER MOTORS H.P. VOLTAGE PHS NO. I H.P. VOLTAGE PHS MISCELLANEOUS TRANSFORMERS: UNDER 000 V. OVER 000 V. NO. KVA NO. KVA NO.NEON TRANSF. NO. VA. MA. MOTOR SIZE SWITCH I FLASHE EACH SIGN --- FORWARDED TOTAL FEES PREPARED BY/RETURN TO: SUNBANK / NORTH FLORIDA , N . A . Bn 200 W F 0 R S Y T H STREET JACKSONVILLE , FL :: 2202 NOTICE OF COMMENCEMENT \ Building Permit No. Tax Folio No. STATE OF FLORIDA COUNTY OF D U V A L (Do not write in this blank area. Reserved for recording purposes only) THE UNDERSIGNED hereby gives notice that Improvements will be made to certain real property, and In accordance with Chapter 713, Florida Statutes ,the following information is provided in this Notice of Commencement. 1. Description of Property: LOT TPLAf BOOKS46,PLAT PAGESF511CAND 51A, U THEN BREEZE OCURRENTNG OPLAT PUBLICTRECORDSAOFRDUVADED (legal description of the property, COUNTY, FLORIDA. and street address if available) 2. General Description of Improvements: Single Family Dwelling 3. Owner Information: a. Name and Address: LARRY E . Walshaw and MICHELLE WALSHAW 2 13 9 Seminole Road , Atlantic Beach , FL 32222 b. Interest in property: J o i n t l y c. Name and address of fee simple titleholder(if other than owner): 4. Contractor: SECON SERVICES d/b/a.J.E. CROSBY COMPANY (name and address) 715 FOREST STREET JACKSONVILLE, FLORIDA 32204 5. Surety: a. Name and address: b, Amount of bond$ 6. Lender Information: a. Name and Address: SUNBANK / NORTH FLORIDA , N . A . 11 NATIONAL ASS0CIA.TI0N 200 W F 0 R S Y T H STREET, JACKSONVILLE , FL 32202 b. Designated Contact: J I L L D L U D K E 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a) 7., Florida Statutes: (name and address) 8. In addition tqq himself Owner ds&&tq�nn tes J I L L 0 L U D K E of SUNBANK / NORTR FLORIDA , N . , to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes 9. Expir tion date of N ' of Commencement(the expiration date is one(1)Ye from the date of recording unless a differ date ' pec' a Other expir tion date: Signaturc f Owner L A R R Y E . W a 1 s h a w Signature oftrer M I C H E L WAL SHAW Signaturc of Owner Signature of Owner STATE OF FLORIDA COUNTY OF DUAL The fotegoing�a 1 s nea wWaa acknowledged bLfOrew A L SgH A W M a S B A N D 9A N D W I F E by LARRY EE E ! : 1 x; 1994 • _uildinu and Zoning ,%RCHITECT/ENGINEERS Cf11t,^tIFICATIOW COASTAL CONSTRUCTION CODE FOR ML IMJOR STRUCTURES TO BE LOCATED WITHIN CITY OF ATLANTIC BEACH, FLORIDA APPLICANT ' S NAME J ` �`'s�y 00 ' PHONE N0.3r'4-S DATE �' S- `y i OWNER NAME: r �2►2V �- I`�liC�.�1�C u�_a�'�l.�.R,E. TAX NO. : TYPE OF PROJECT: Xv )New Home ( )Residential Addition ( )Garage ( )Pool ( )New Commercial ( )Commercial Addition ( )Other 911 STREET ADRESS: ZT7 70640 77777777— We 'claim the structure -to be exempt as follows: ( ) Garage with no provision for occupancy - detached one and two family only ( ) Pier, Dock, etc. ( ) Other (Specify) I also certi t a no structure listed above may be remodeled z . converte , o a n xempt use without being upgraded to fulir comply w t e n Signed: ;7„'" Date: ----------------------- --------------------------------- -- CERTIFICATION This certifies that the plans and specifications submitted a,i.i sealed by the undersigned meet all criteria set forth by the Cit . of Atlantic Beach Coastal Construction Code. Roof covering is exempt from the 110 mph requirements of the Coastal Constructic.: Code, but meet all the other requirements of the City of Atlantic Beach Building Code. (A The structure including foundation, frame, roof deckir.g , exterior walls and floors has been designed for wind loads of 110 mph, with all design complying with.the 19171 , Chapter 12 , Standard Building Code. ----------------------------------------------------------------- ( ) Windows, doors and all other exterior devices comply with ti.e 110 mph wind load. --------------------------------------------------------------- - - ( ) Tho structure is located outside the area affected by wave forces, OR ( ) The structure is capable of withstanding wave forces result::::: from a wave crest height of feet above MSL includi:,.: uplift forces. - ------------------------------------------------------------- ( ) The structure is located in PIA Zone A and the foundati(-_: design has considered possible exposure to water and erosi•::, . OR (J� The structure is located in FIA ;one X and the foundation wl '. . not be exposed to hydrodynamic, hydrostatic loads or water scour, OR 1 . ( ) Foundation design has been completed with floor elevatic::: above the specified Stillwater elevation, and to resist wavy: hydrodynamic, hydrostatic and wind loads acting simultaneous with dead loads. Erosion computations for the foundatio , design have taken into account the nrniae-toA An