Loading...
Permit Fire Sprinker 98 W 3rd St 2012 ,. f' t�`1'�j lJ CI :P ' * s' CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 c INSPECTION PHONE LINE 247 -5814 Alp. ---- on Number 11- 00002603 17rnp ty n ` arR re$s Date 2/22/12 RE number 02 W ?BD qT NCR OLD ACCOUNT NUMBERS 17 0833 -1000- - Application type description SINGLE FAMILY ATTACHED DWELLING Subdivision Name Property Use Property Zoning TO BE UPDATED Application valuation . . . 80000 Owner Contractor BEACHES HABITAT BEACHES HABITAT 1671 FRANCIS AVE. 1671 FRANCIS AVENUE ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241 -1222 (904) 241 -1222 Structure Information 000 000 Construction Type TYPE 5 -B Occupancy Type RESIDENTIAL Flood Zone ZONE X Other struct info SQUARE FOOTAGE 1509.00 Permit MECHANICAL FIRE SPRINKLER Additional desc . Sub Contractor . MILTON J WOOD FIRE PROTECTION Permit Fee . . . 85.00 Plan Check Fee . Issue Date .00 Expiration Date Valuation . . . . 0 2/22/12 Qty Unit Charge Per Extension BASE FEE 55.00 1.00 30.0000 EA M FIRE SPRKL 1ST 40 HEADS 30.00 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONA1 ELECTRIC CODE WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Since on -site storage is required, a post construction topographic survey documenting proper construction will be required, prior to issuance of C.O. Full right -of -way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. Call Public Works (247 -5834) for Erosion and Sediment Control Inspection prior to the start of construction. Other Fees STATE DCA SURCHARGE 6.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. �� CITY OF ATLANTIC BEACH U " ;) 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 � INSPECTION PHONE LINE 247 -5814 Jf319 � aryl ; ray; r„Z DTt�tnbQr Page 2 11- 00002603 Das 2/22/12 Other Fees DEV REVIEW - SINGLE & 2 -FAM 50.00 ENG REV RESIDENTIAL BLD 100.00 STATE ELEC DCA SURCHARGE 2.00 STATE MECH DCA SURCHARGE 2.00 STATE PLBG DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 STATE PLBG DBPR SURCHARGE 2.00 STATE DBPR SURCHARGE 6.00 SEWER SDC- SYSTEM DEV CHG 4050.00 UTIL REV RESIDENTIAL BLDG 50.00 WATER CONNECT /METER ONLY 185.00 WATER CROSS CONNECTION 50.00 WATER SDC- SYSTEM DEV CHG 1140.00 Fee summary Charged Paid Credited Due Permit Fee Total 85.00 85.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5649.00 5649.00 .00 .00 Grand Total 5734.00 5734.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. (1v Habitat for Humanity 96 & 98 West 3rd Street Fire Protection Project Submittal Package CITY 0f AILA O C BEACH BUILDIN Va 22 2012 d caikAA FILE COPY p pr MILTON J. r WOOD Fir FIRE PROTECTION Milton J. Wood Fire Protection Inc. 3805 Faye Road, Jacksonville, FL 32226 (904) 353 -4055 / (904) 353 -8486 FAX rMOMB IMP MO AMINIM. i .1■111* 4111 �r _ i• I& Or f 111•1•111•1111111M WY ICY. dM\ lllllllllll1•l•i 4WI IrW1� ■YWWYIWI01111 M AIM .YIIMINWWIIL NI* AP .1•1111111111. Fire Protection by Computer Design Society of Fire Protection Engineers (SFPE) Northeast Florida Chapter 904 - 353 -4055 Job Name : 96 -98 W. 3rd Street Building Location : 96 & 98 West 3rd St., Atlantic Beach, Florida 32233 Remote Area Contract Data File : SFPE - Habitat- 02.wxf Mr"- Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Society of Fire Protection Page 1 96 -98 W. 3rd Street Date 01/27/2012 ,.. HYDRAULIC DESIGN INFORMATION SHEET dme - Habitat for Humanities Date - 02 -16 -12 Location - 96 & 98 West 3rd St., Atlantic Beach, Florida 32233 Building - System No. - Contractor - Society Fire Protection Engineers SFPE Contract No. - Calculated By - Joshua Roman Drawing No. - Construction: ( ) Combustible ( ) Nan- Combustible Ceiling Height 8' -0" OCCUPANCY - 1 & 2 Family Dwellings - Residential S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 ( )2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 14 Gpm System Type Listed Pres. at Start Point - 8.2 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 5 Gpm Make Victaulic Model V27 2 Elevation at Highest Outlet - 8' -8 "Feet Size 1/2" (7/16 ") K- Factor 4.9 G Note: Temperature Rating 155 ° F N Calculation Gpm Required 33.25 Psi Required 39.79 At Source Summary C- Factor Used: Overhead 150 Underground 150 Water Flow Test: Pump Data: Tank or Reservoir: Date of Test - 02/16/2012 Rated Cap. Cap. T Time of Test - 9 :OOam @ Psi Elev. E Static (Psi) - 48 Elev. R Residual (Psi) - 40 Other Well Flow (Gpm) - 1060 Proof Flow Gpm S Elevation - 1 P Location: 96 & 98 West 3rd Street, Atlantic Beach, Florida 32233 P L Source of Information: City of Atlantic Beach Utilities Department Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 N O N ti . N r '4'r'T ` ( O . •- N N <- c c c c0 a) • a) co co . W ❑ a) - . = c V) c0 Oc• ' C LL CL c C . O O E E E E m o ( co 6 a) N O (1) cZ3 r— W CO C!) "(1) >, - 1 u) 1 c NN OM (a (o❑❑ ❑2 ❑U) E a.) - ❑ r-- co . o co 0 .o Q o (/) o 0 Z . E c0 L 0 C T No x U ~ U y 00 is O ,-- T 0 < _ i z E U O1 m - o t a. o °' • o . o a E 0 U .o o ' . , 0 o . c0 CO O O v v <- . .. 4) ., L 3 0 a.) c 0 ,_ O : co > g a L • U ` CO N a = = , o U,.r..o A a_o a 70 o ... 7 TA u) : 1 - c� Q) cn lY tx U ❑ I' o Cy �a 0 . . . 0 • 01 V) o 3000 N - 1 � a) ty� CO >. 0 0 CO o 0 0 0 0 Cr 0 0 0 0 0 0 0 0 CI .0 O 0 <- T- <- - <- co CO r- (.0 X) M N (A rn O. r W C/) C/) D CC W cv 3 Q Q oc§ / _ P \ R S 0 , 3 2 LC) 2007 CD CD / 0 00 00 » » G woom 2 N. c 0 0 2 0 R �oc2 = 2 #ooG \ 0 = 2 n00 / 5 � � » aoo g z E 9 �1 » N00 / / _ —oo» c - ell' I \ \ \ n w � 2 » 5 q - /= § E I I n . o �Gmt4 \ 0 — 1-22 \ 2 a)£ \ / R a . } moo ) ' \ 2 � ® / 2 « .- ,- _ ,_ § ± eg\ £$ -. m�;§ li o.6 1 Q g g - © _ - } om =en \ >, E m m R777 @ o o = c o o = � = = = \ ƒ //2 } « x c m o m &% ƒt c N j o N - i) )� / / \k \ / am =e 0 7 2 c% E o 4 N § own Tt§ £/ X33 '&3« $ \ CO � � 2 / 2 § 2 -¢ - _ /t Eom o 0') 01 £ u_ =I 72 i E CC 336 § \k \ \ g @ m m 2R% � � _« m w u) 0 *•co .- 2 2 , ¢% (TS ) : m > ! ! ` \ }/§ =�_ E # . / { §2 § 2 &o = =m£ 1 1 _ __ m 2 2 =2E� = 0 5 0 _ io _ © m �2 \5 / \ G§ 4 § ®) � a 2 � \ Q72G42� a 3 C Oc 0 ® } 2 / 7 / 7 \ §f E co E E / co § • CO �o� = = =- E = ® o�� \ � ¢ f Z z =ZOOz § m = \\ a)/% § 3c =¢ m 5 = =2 � 7 oJku_ \ / =., 7 22 /2 U : \ 3 n= _< u / 5� ZWo0 Pressure / Flow Summary - STANDARD Society of Fire Protection Page 4 96 -98 W. 3rd Street Date 01/27/2012 �pde Elevation K -Fact Pt Pn Flow Density Area Press �"" Actual Actual Req. 1 8.167 4.9 8.2 na 14.03 0.05 256 8.2 3 8.167 4.9 8.42 na 14.22 0.05 256 8.2 2 8.667 8.39 na 4 8.667 11.15 na TOR 8.667 •11.58 na BOR 1.0 19.71 na 5.0 UG1 -2.0 38.2 na UG2 -2.0 41.09 na UG3 -2.0 41.09 na SRC 1.0 39.79 na The maximum velocity is 6.99 and it occurs in the pipe between nodes BOR and UG1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams Society of Fire Protection Page 5 • 96 -98 W. 3rd Street Date 01/27/2012 igr klyd. Qa Dia. Fitting Pipe Pt Pt ef. "C" or - Ftng's Pe Pv * ****** Notes * * * *** Point Qt Pf /Ft Eqv. Ln. Total Pf Pn 1 14.03 1.394 2N 16.0 14.042 8.200 K Factor = 4.90 to 150.0 10 6.0 ' 22.000 -0.217 2 14.03 0.0112 0.0 36.042 0.404 Vel = 2.95 0.0 14.03 8.387 K Factor = 4.84 3 14.22 1.394 1N 8.0 1.833 8.422 K Factor = 4.90 to 150.0 10 6.0 14.000 -0.217 2 14.22 0.0115 0.0 15.833 0.182 Vel = 2.99 2 14.03 1.394 3N 24.0 37.583 8.387 to 150.0 10 6.0 30.000 0.0 4 28.25 0.0409 0.0 67.583 2.761 Vel = 5.94 4 0.0 1.394 1N 8.0 2.625 11.148 to 150.0 0.0 8.000 0.0 TOR 28.25 0.0408 0.0 10.625 0.434 Vel = 5.94 TOR 0.0 1.394 2Fsp 0.0 7.500 11.582 to 150.0 0.0 0.0 7.821 * Fixed loss = 4.5 BOR 28.25 0.0408 0.0 7.500 0.306 Vel = 5.94 BOR 5.00 1.394 1E 4.762 134.000 19.709 Qa = 5.00 to 150.0 1T 9.523 14.284 10.306 * Fixed loss = 9.007 UG1 33.25 0.0552 1Zik 0.0 148.284 8.189 Vel = 6.99 iG1 0.0 1.598 2T 23.312 37.000 38.204 150.0 0.0 11.656 1.500 * Fixed loss = 1.5 UG2 33.25 0.0284 0.0 48.656 1.382 Vel = 5.32 UG2 0.0 8.425 0.0 15.000 41.086 to 140.0 0.0 0.0 0.0 UG3 33.25 0.0 0.0 15.000 0.0 Vel = 0.19 UG3 0.0 6.275 1E 21.977 15.000 41.086 to 140.0 1G 4.709 73.780 -1.299 SRC 33.25 0.0 1T 47.094 88.780 0.004 Vel = 0.34 0.0 33.25 39.791 K Factor = 5.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqcci I Fire & Building Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Technical Tyco® CPVC Pipe and Fittings pro- Data � duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively Sizes for use in wet pipe automatic fire sprin- 3/4" to 3" kler systems. The Tyco CPVC Pipe Maximum Working Pressure and Fittings are produced from Blaze- 175 psi Master® CPVC compound that is a specially developed thermoplastic Approvals . 'rA compound composed of post chlorin- UL, FM, C -UL, ,NSF, LPCB, MEA, and ated polyvinyl chloride (CPVC) resin the City of Los Angeles. (Refer to In- u and state of the art additives. Tyco stallation Handbook IH -1900 dated .w CPVC Pipe and Fittings are easier to June 2008 for exact listing /approval install than traditional steel pipe sys- information.) tems, and at the same time, provide Manufacture Source superior heat resistance and strength U.S.A. as compared to traditional CPVC and PVC piping materials used in the Material plumbing trade. Various adapters are • Pipe: ASTM F442, SDR 13.5 available to connect CPVC pipe to me- tallic piping. All female pipe thread • Fittings: ASTM F438 (Sch. 40) and adapters have brass inserts for dura- ASTM F439 (Sch. 80), ASTM F1970 bility. Grooved adapters connect di- Color rectly to grooved end valves and me- Orange tallic pipe, with flexible grooved end couplings. NOTICE Tyco CPVC Pipe and Fittings pro- duced with BlazeMastero CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler e manufacturer should be contacted with any questions. BlazeMasters is a registered trademark of The Lubrizol Corporation Page 1 of 2 JUNE, 2008 TFP1915 Two -Hole Side Mount CPVC Pipe Straps Application: The Two -Hole Side Mount CPVC Pipe Strap is designed to support pipe running > perpendicular to the beam. When attached to the bottom of the beam it supports: f' , the pipe, but when attached to the top of the beam it will only act as a guide. .. Nr Features: - . • Beveled edges protects CPVC pipe from damage ,.> • Easily attaches to wood structure with included screws or to minimum fir," 20 gauge steel with special screws (sold separately) • Retaining dimples simplify installation process • Strap is UL Listed • Sizes: 3 /4" (19mm) through 2" (50mm) CPVC pipe LISTED • Includes: one (1) pipe strap and two (2) #10 x 1 hex head screws Optional: 1 /4" x 1" (25.4mm) tek type screw for mounting to steel (sold separately) • Strap has two (2) 1 /4" (6.3mm) diameter hole for mounting • Material: 20 gauge (0.9mm) x 1 (28.6mm) pre - galvanized steel UPC Part D Nominal W C HC Maximum Wt. Number Number Pipe Dia. Overall Spacing Per 100 in. mm in. mm in. mm in. mm in. mm lbs. kg 78205160075 B3183 - 3 /4 1.050 26.7 2 58.7 1 1 43.8 1 47.6 66 1676 9.0 4.1 #4.16* 78205160076 ; 83183 - '' 1.315 33.4 2 65.1 1 49.2 2 55.6 72 1829 10.0 4.5 78205160077 83183 -1 1.660 42.1 2 74.6 25/16 58.7 2 _ 63.5 78 1981 11.0 5.0 78205160078 83183 -11/2 1.900 48.2 31/4 82.5 25/8 66.7 2i3/16 71.4 84 2133 1 2.0 5.4 78205160079 83183 - 2 2.375 60.3 3 92.1 3 76.2 3 82.5 96 2438 1 3.0 5.9 Nominal Pipe Diameter W --. D Support Application Guide Application �� . r l!it / k ;, ,°' ,...;',. , , , : : "-:re,-' Ivo -moo 1410, . L " d � P HC ' :> ,„,,,, \ NM w s haw -�' 4 , 4 Perpendicular pipe run Perpendicular on pipe ea' bottom mounted on wood joist top mounted COOPER B - Line One -Hole Wrap Around CPVC Pipe Straps Application: The One -Hole Wrap Around CPVC Pipe Strap is designed to support pipe running horizontally on the side of a beam. It can also be used, as a guide, to mount CPVC pipe that runs perpendicular across the top of a beam or on a vertical pipe run. Features: • • Beveled edges protects CPVC pipe from damage • Easily attaches to wood structure with included screws or to minimum 20 gauge steel with special screws (sold separately) • Strap is UL Listed • Sizes: 3 /4" (19mm) through 2" (50mm) CPVC pipe (DO • Includes: one (1) each pipe strap and #10 x 1 hex head screw LISTED Optional: 1 /4" x 1" (25.4mm) tek type screw for mounting to steel (sold separately) • Strap has one (1) 1 /4" (6.3mm) diameter hole for mounting • Material: 20 gauge (0.9mm) x 1 (28.6mm) pre - galvanized steel UPC Part D Nominal L t} Maximum Wt. Number Number Pipe Dia. Overall Spacing Per 100 in. mm in. mm in. mm in. mm lbs. kg 78205160064 33181 1.050 26.7 2 60.3 1 34.9 66 1676 9.0 4.1 78205160065 B3181 - 1.315 33.4 2 66.7 1 36.5 72 1829 10.0 4.5 78205160066 83181 - 1 1 /4 1.660 42.1 2 47.6 1 39.7 78 1981 '; 2.0 5.4 78205160067 B3181 - 11/2 1.900 48.2 3 77.8 1 41.3 84 2133 12.0 5.4 78205160068 33181 - 2.375 60.3 3 87.3 1 46.0 96 2438 15.0 6.8 Support Application Nominal Pipe Diameter 44JA ,n as f L ca r nm ` Gui a Applications �� F n a d A I c n �es�S4 * 4r rah T ; £' rw � J ,. = a �, r y ` �7� ,? ,�.°" , yam Horizontally mount CPVC pipe � a Running CPVC pipe vertically Running CPVC pipe perpendicular across top of beam COO B -Line FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS "r V27 K4.9 AZ 020 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 M'^ These Model V27 residential sprinklers are designed to meet the requirements of NFPA 13, 13D and 13R for residential use in a variety of room sizes, depending upon available operating pressure and room configuration. Model V2734 is UL Listed for use under smooth flat horizontal ceilings and sloped ceilings up to and including 8/12 (33.7 °) pitch. The design incorporates DOME COVER PLATE state -of- the -art, heat responsive, frangible glass bulb design (quick response) for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex - shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various finishes to meet many design requirements. The V27 sprinklers are now available with the aesthetically pleasing dome cover plate, which • also is available in various finishes to meet many design requirements. SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire COVERAGE: Residential spray coverage up to 20 feet x 20 feet (6.1 m x 6.1 m) room sizes per NFPA. TECHNICAL SPECIFICATIONS: Models: V2734, V2736 ACCESSORIES Style: Concealed Residential Pendent Installation Wrench: Nominal Orifice Size: 7 /16712mm • Concealed: V39 K- Factor: Finishes: • V2734 - 4.9 Imp. /7.1 S.I.^ for room sizes • Chrome plated up to 16'/4.9 m. • White painted • V2736 - 4.9 Imp. /7.1 S.I.A for room sizes • Flat black 18' to 2075.5 and 6.1m. • Custom painted Nominal Thread Size: 1/2" NPT /15mm For cabinets and other accessories refer to Max. Working Pressure: 175 psi /1200kPa separate sheet. Factory Hydrostatic Test: 100% (� 500 psi /3450kPa A For K- Factor when pressure is measured in Min. Operating Pressure: 7psi /48kPa Bar, multiply S.I. units by 10.0. Temperature Rating: See chart on page 2. * Teflon is a registered trademark of Dupont Co. MATERIAL SPECIFICATIONS Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: • Quick Response: 3.0mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Seal: Teflon* tape Frame: Die cast brass 65 -30 Cup: Cold rolled steel, zinc - chrome plated. Cover /Escutcheon: Brass per UNS C26000 JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com \iCtauliC" viCTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA REV_E 40.42_1 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40.42 v27, K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 RATINGS At glass bulbs are rated for temperatures from —67 °F ( -55 °C) up to those shown in table below. SPRINKLER — V2734/V2736 COVER — V27 Sprinkler Temperature — "F / "C Cover Temperature — "F / °C Maximum Maximum Sprinkler Victaulic Nominal Ambient Victaulic Nominal Ambient Temperature Part Temperature Temperature Glass Bulb Part Temperature Temperature Classification Identification Rating Allowed Color Identification Rating Allowed Ordinary C 155 100 Red A` 135 1 00 68 38 57 `A for use with Standard or Quick Response Concealed Sprinklers 135°F (57 °C) or 155°F (68 °C). • Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. • The plastic shipping cap must be removed for the sprinkler to operate properly. • If shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the fire protection system shall be considered out of service, the Authority Having Jurisdiction notified, and a firewatch is suggested. Failure to do so may result in failure of sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K- Factor Thread Size Quantity ...... .................._............ _ Cover Finish Wrench Model Number www.victaulic.com \iCtaulic' VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED, PRINTED IN THE USA REV _E 40.42_3 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.42 V27, K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 ROOM SIZE Installed Under Smooth Flat Horizontal Ceilings up to 2/12 (9.5 ° ) Pitch Minimum Flow per Sprinkler Min. Nominal tor Horizontal Ceilings Installation K- Factor Maximum 2/12 (9.51 Pitch Room Size Spacing Imperial For NFPA 139 or 1313' Model Feet /meters Feet /meters S.I. ^ GPM /LPM @ PSI/kPa V2734 12 x 12 8.0 4.9 13 GPM @ 7.0 PSI 3.7 x 3.7 _2.4 7.1 _ 49.2 LPM @ 48.5 kPa V2734 14 x 14 8.0 4.9� 13GPM 7.0 PSI 4.3 x 4.3 : 2.4 7.1 I 49.2 LPM @48.5 kPa V2734 16 x 16 8.0 4.9 14 GPM @ 8.2 PSI 4.9 x 4.9 2.4 1 7.1 1 53.0 LPM @ 57.0 kPa • 12x12 8.0 r 4.9 ': 13GPM @7.OPSI V2736 3.7 x 3.7 1 2.4 7.1 49.2 LPM @ 48.5 kPa V2736. 14 x 14 8.0 4.9 17GPM @ 12.0PS( 4.3 x 4.3 2.4 • 7.1 64.3 LPM @ 83.0 kPa • V2736 16 x 16 8.0 4.9 17GPM @ 12.0P51 4.9 x 4.9 i 2.4 7.1 1 64.3 LPM @ 83.0 kPa V2736 18 x 18 8.0 4.9 17GPM @ 12.OPS( �__.,._.._...5 ...,.;,..__._.._..._Z4._... _ ..._......_. _. - , ....643 LPM @ 83.0 kPa V2736 I 20 x 20 8.0 4.9 20GPM @ 16.7 PSI 6.1 x 6.1 2.4 7.1 1 75.7 LPM @ 114.9 kPa Installed Under Sloped Ceilings up to 4/12 (18.4 °) Pitch Minimum Flow per Sprinkler Min. Nominal tor Sloped Ceilings Installation K- Factor Maximum 4/12 (18.4 ") Pitch Room Size Spacing Imperial For NFPA 13R or 13D` Model Feet/meters Feet /meters S.I." GPM /LPM @ PSI /kPa V2734 ` 12x12 8.0 49 19GPM @15PSI fik' 3.7 x 3.7 2.4 7.1 71.9 LPM @ 103.0 kPa V2734 1 14 x 14 8.0 4.9 19GPM @ 15 PSI 4.3 x 4.3 1 2.4 7.1 71.9LPM @ 103.0kPa 16 x 16 1 8.0 4.9 19GPM19 15 P51 V2734 4.9 x 4.9 1 2.4 7.1 i 71.9 LPM @ 103.0 kPa V2736 12 x 12 8.0 4.9 21 GPM @ 18.5 PSI 3.7 x 3.7 2.4 -- w v N - 7.1 w 79.5 LPM 128 kPa -� 14 x 14 �~ 8.0 4.9 21 GPM @ 18.5 PSI V2736 4.3 x 4.3 2.4 7.1 79.5 LPM @ 128.0kPa V2736 16 x 16 8.0 4.9 21 GPM @ 18.5 P51 I 49 x 4.9 2.4 7.1 79.5LPM @ 128.0 kPa V2736 18 x 18 8.0 4.9 21 GPM @ 18.5 PSI 5.5 x 55 2.4 1 7.1 1 79.5 LPM @ 128.0 kPa V2736 20 x 20 8.0 4.9 28GPM @32.6P51 • 6.1 x 6.1 2.4 7.1 106.0 LPM @ 225.0 kPa Installed Under Sloped Ceilings up to 8/12 (33.7 °) Pitch Minimum Flow per Sprinkler Min. Nominal for Sloped Ceilings Installation K- Factor Maximum 8/12 (33.71 Pitch Room Size Spacing Imperial For NFPA 13R or 130` Model Feet /meters Feet /meters S.I. ^ GPM /LPM 0 PSI /kPa • V2734 •2 x 12 8.0 4.9 21 GPM @ 18.4 P51 3.7 2.4 7.1 79.5LPM @127.0kPa • V2734 14 x 14 8.0 4.9 21 GPM @ 18.4P51 43x4.3 2.4 7.1 79.5 LPM @ 127.0 kPa V2734 16 x 16 8.0 4.9 21 GPM @ 18.4 PSI 4.9x4.9 2.4 7.1 79.5 LPM @127.0kPa V2736 12 x 12 8.0 4.9 - 37x3.7 2.4 71 - • V2736 14 x 14 8.0 4.9 - 4.3 x 4.3 2.4 7.1 - V2736 16 x 16 8.0 4.9 - 4.9 x 4.9 2.4 7.1 - V2736 18 x 18 8.0 4.9 - 5.5x5.5 2.4 7.1 +*- V2736 20 x 20 8.0 4.9 6.1 x 6.1 2.4 7.1 - www.victaulic.com NiCtauIic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. (0 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA REV _E 40.42_5 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40.42 e"'" V27 K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 NORMAL WETTING PATTERNS MODEL V2736 K4.9 RESIDENTIAL CONCEALED 13 GPM (49.2 LPM) 2.4m ,.. T ti. 2.1m 095•' -w.R"" 1 I «� i'„ w , ' N ,. taw 12m UM 03 ,0 y ... ROOM .... —,... �_... _. _.. ....... ...:z NOMINAL WETTING PATTERN 12' x 12' COVERAGE AREA MODEL V2736 K4.9 RESIDENTIAL CONCEALED 17 GPM (64.3 LPM) 2.4 m 2.1 m O.B 9' 8 e' 2.4m 1.8m 12m 4b 0.3m lam . ROOM NOMINAL WETTING PATTERN 18' x 18' COVERAGE AREA MODEL V2736 K4.9 RESIDENTIAL PENDENT AND RECESSED PENDENT 20 GPM (75.7 LPM) 0' »_., .,.. ....._ ....__. _ _._.,., 39 2 1.2 m 0.9m O.Bm Iepm 2,em 1.11m Il m Obm e . .e 03m 2 C L OF ROOM OA m NOMINAL WETTING PATTERN 20' x 20' COVERAGE AREA NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor- wetting, and wall- wetting patterns for these specific Victaulic FireLock automatic sorinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com ✓ctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VCTAULIC COMPANY. ® 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA V P, EV E 40.42_7 ""' tuco Fire Suppression & Building Products ift rapid response® HOME FIRE SPRINKLER SYSTEM Technical Services 800 - 381 -9312 I +1- 401 - 781 -8220 www.tyco- fire.com Model RSV -1 Residential Shut -Off Valve 1 Inch and 2 Inch (DN25 and DN50) for Dual - Purpose Residential Water Supply General NOTICE The Model RSV -1 Residential Shut -Off Description Valves described herein must be installed The TYCO RAPID RESPONSE Model and maintained in compliance with this e document, as well as with the applicable ;, s RSV -1 Residential Shut -Off Valves standards of the National Fire Protection ' '� - ; � � � 4. . - A ssociation, in addition to the standards are intended for use in dual-purpose r O ( residential water supply piping that of any authorities having jurisdiction. , ,„ serves both domestic and residential f.:j , . F ailure to do so may impair the integrity fire protection sprinkler system needs. of this device. The 1 -Inch (DN25) Valve is intended o, for NFPA 13D system needs, whereas Owners are responsible for maintaining ,, the 2 -Inch (DN50) Valve is intended for their fire protection system and devices in z.: systems designed in accordance with proper operating condition. The installing either NFPA 13D or NFPA 13R. contractor or sprinkler manufacturer . should be contacted relative to any When a fire sprinkler operates, the questions. Physical Characteristics Model RSV -1 Residential Shut -Off Refer to Figures 3 and 4. Valve automatically shuts off water L • 1 -inch (DN25) Valve flow to the domestic system and di- Technical Body Copper Alloy verts the available water supply to the and Top fire sprinkler system. Consequently, Data T otam Cover Copper Alloy when the Model RSV -1 Valve is uti- lized, the system designer does not Approvals Upper Cap Brass need to add the domestic flow de- • The 1 -Inch (DN25) Model RSV -1 Resi- Bottom Seal Brass mand to the fire sprinkler system flow dential Shut -Off Valve is UL and C -UL Piston Glass Reinforced demand, as would otherwise be re- Listed and NSF -61 Annex G Approved. Polyphenylene Oxide quired by NFPA 13R. It is suitable for use in water supply Differential Consider use of the Model RSV -1 arrangements for residential fire sprin- Ring Glass Reinforced Residential Shut Off Valve when either kler systems designed per NFPA 13D. Polyphenylene Oxide the water supply cannot adequately • The 2 -Inch (DN50) Model RSV -1 Resi- Sleeve Glass Reinforced provide for both the domestic design dential Shut -Off Valve is UL and C -UL Polyphenylene Oxide demand and the fire sprinkler flow de- Listed and NSF -61 Annex G Approved. Upper and mand, or it is necessary to increase It is suitable for use in water supply Lower Seals EPDM the effectiveness of the fire sprinkler arrangements for residential fire sprin- O -Rings Buna -N system by automatically shutting off kler systems designed per NFPA 13D Piston Spring Stainless Steel the domestic flow. or 13R. Piston Screws Stainless Steel The Model RSV -1 Residential Shut- Maximum Pressure Cap Screw Stainless Steel Off Valve maximizes the effective use 175 psi (12,1 bar) • 2 - Inch (DN50) Valve of an existing water supply. Therefore, Body and in areas with limited water supplies, it Weight Cover Copper Alloy may eliminate the need to add costly 1 -Inch (DN25): 11 lbs. (5 kg) Piston Insert Copper Alloy pumps, pressurized reservoirs, or elec- 2 -Inch (DN50): 29 lbs. (11 kg) Bottom Seal Copper Alloy trically operated domestic shut -off Piston Cover .... Glass Reinforced valves. The Model RSV -1 Valve has a Pressure Loss Polyphenylene Oxide built -in check valve in the fire sprinkler Refer to Figures 7 and 8. Insert Sleeve ....Glass Reinforced system outlet that eliminates the need patents Polyphenylene Oxide for a separate check valve. Also, the e Model RSV -1 Valve automatically re- 2-Inch (DN50) Model RSV -1 Valve: Piston Seal EPDM sets, thereby eliminating the need for Patent Pending O -Rings EPDM valve disassembly after a fire sprinkler Piston Spring Stainless Steel system test or operation. Piston Nut Stainless Steel Retainer Ring Stainless Steel Page 1 of 8 DECEMBER 2010 TFP980 TFP980 Page 3 of 8 ow Operating Principles y 3 -5/8" DIA. FIRE Components: ( mm) SPRINKLER When a fire sprinkler activates dur- PORT, 1" NPT ing domestic usage, the TYCO Model 1 - Body 2 - Top Cover 2 RSV -1 Residential Shut -Off Valve i 3 - Screw, automatically shuts off flow to the 5 i�� Upper Cap domestic system and diverts the avail- DOMESTIC able water supply to the fire sprinkler 4 Upper Cap 3 hi ' N PORT, 3 -1/4" 5 - 0-Ring, t►� ��T \ \\ 14 (82,6 mm) system, thereby eliminating a reduced Cover (2) 4 � ii 1" NPT flow condition in the sprinkler system °' a'' � ,/ wob that might otherwise be caused by 6 - 0-R ing, 6 • possible significant domestic water Upper Sleeve J I _M.., HU 15 8- 3/16" 7 usage. 8 - Sleeve :::::= : (208,0 mm) When the Model RSV -1 Valve is in the Spring 8 9 "�� .Q.';;�":"�.; I 10 9 S normal standby position as shown in 10 Differential v I 'V 4- 15/16" Figures 7 and 8, the Piston Assembl , Ring 9 ./ " I: �z 11 (125,4 mm) assisted by its Spring y 11 Lo wer Seal � ; '; '� s ,� �� y p ng, is rn the down 1 .§ I 14 position. With the Piston Assembly in 12 - Screw ;. the down position, the Fire Sprinkler Piston (4) 12 5 Seal permits the Model RSV -1 Valve 13 Bottom Cover .E d to perform as a conventional check 14 Piston 13 valve. Also, with the Piston Assembly 15 0-Ring, WATER in the down position, water is avail- Lower Sleeve SUPPLY 2-3/8" able on demand through the Domestic PORT, 1" NPT (60,3 mm) Flow Passage and out the Domestic Port. FIGURE 3 Upon operation and with a mini- 1-INCH (DN25) MODEL RSV -1 RESIDENTIAL SHUT -OFF VALVE mum design water flow —that is, 72.5 ASSEMBLY AND DIMENSIONS 1 GPM (47,3 LPM) for the 1 -inch Valve or 8 GPM (30,5 LPM) for the 2 -Inch Valve —to the automatic residential fire sprinkler system, the Piston Assembly 5-3/8" DIA. FIRE moves upward. With the Piston As (136,5 mm) 1 SPRINKLER sembly in the up position, any water 12 PORT, 2" NPT flow to the Domestic Port is diverted to the Fire Sprinkler Port. 10 The contours of the Piston Assembly 1 D' - Components: �+ DOESTIC are specifically configured to minimize Q . PORT M , its upward movement except under 1 - Body 6 the level of sustained fire sprinkler 2 Insert Sleeve i t \ 2" NPT 4 -1/2" system flow resulting from operation 3 Bottom Seal 5 (114,3 mm) of one or more fire sprinklers. How- 4 Piston Cover 11 Q ever, because most fire sprinkler sys- 5 - Piston Seal �,� !� terns contain air 6 - Piston Insert g 7 - P isto n Spring tl`g G �' j �i pockets, the Piston p ' 9-1/16" Assembly tends to move momentarily p g Vk,1 I %' (230,2 mm) 8 - Piston Nut 2 upward when there is a surge in sup- It, 9 - Insert Sleeve ply pressure. 0-Ring (2) 4 � ` �AV `\ \em:7 alleblege The momentary opening and re -clos- 10 - Cover 0 -Ring g 14. 4- 9/16" ing of the Piston Assembly at the Fire 11 Retainer Ring o (115,9 mm) Sprinkler Line Seal traps a portion 12 - Cover 3 a � of the pressure increase within the 13 - Bottom Seal 13 V - fire sprinkler system. Trapped pres- 0-Ring a_ `` `4 sure increases within the fire sprinkler 7 system help to prevent a subsequent WATER surge in the supply pressure from 8 SUPPLY 3 -3/4" causing the water -flow detector to sig- PORT, 2" NPT x (95,3 mm) nal a false alarm (unless a by -pass is installed per Figure 2). FIGURE 4 2 -INCH (DN50) MODEL RSV -1 RESIDENTIAL SHUT -OFF VALVE ASSEMBLY AND DIMENSIONS . TFP980 Page 5 of 8 FIRE SPRINKLER PISTON TO FIRE FIRE PORT ASSEMBLY PISTON SPRINKLERS SPRINKLER ORT \ ASSEMBLY PORT 7 FIRE FIRE FIRE SPRINKLER SPRINKLER. r„, , $ SPRINKLER �" y SEAT SEAT y FLOW • � � ( ( / /������U � V i. DOMESTIC �'' �(/,I1�, "1 l} oV PASSAGE 4 �i .1 TO DOMESTIC 7 DOMESTIC Mil �,l DOMESTIC FLOW y'r �;,��_ ��.Q INTERNAL , — �w PORT PASSAGE % wI \ r. i 5% = :_:5 BY - PAS S g • —... — 'a !' %�� � _�5 \ RESTRICTION a Q` 5 - 5 DO MESTIC t J t �� SEAT �� r / 'C DOMESTIC � Y SUPPLY j j -� SUPPLY PORT SEAT PORT SUPPLY SUPPLY STANDBY OPERATED FIGURE 7 STANDBY AND OPERATED POSITIONS FOR 1 -INCH (DN25) MODEL RSV -1 VALVE TO FIRE FIRE SPRINKLERS FIRE SPPIONRTER ---2--;...7.---- PISTON PISTON SPRINKLER ASSEMBLY ASSEMBLY r� �� PORT FIRE �� I FIRE N S . SPRINKLER FIRE N #� SPRINKLER FLOW � Q' SEAT SPRINKLER a ,� `Z►� \ PASSAGE ac bli ` SEAT DOMESTIC MI `" PORT �;�.�II►`C \ . CVO '` QV �/ �. DOMESTIC ►. UNION / N DOMESTIC :∎ / I pp FLOW DOMESTIC DOMESTIC PASSAGE 1w SEAT INTERNAL SUPPLY PORT BY -PASS \ v 'k • RESTRICTION /� SUPPLY PORT . j A f � PORT SUPPLY DOMESTIC \ SUPPLY STANDBY SEAT OPERATED FIGURE 8 STANDBY AND OPERATED POSITIONS FOR 2 -INCH (DN50) MODEL RSV -1 VALVE TFP980 Page 7 of 8 Operation Test Procedure Limited Ordering 1. Fully open two or three water outlets in the domestic piping system. Warranty Information 2. To simulate a sprinkler operation, open the Alarm Test Connection of Products manufactured by Tyco Contact your local distributor for avail - the fire sprinkler system. Fire Suppression & Building Prod- ability. When placing an order, indi- ucts (,TFSBP) are warranted solely to cate the full product name and Part 3. Verify that any alarms are operating the original Buyer for ten (10) years Number (P /N). and that the flow from the domestic against defects in material and work - water outlets decreases to no more manship when paid for and properly Valves with NPT Connections than a trickle. installed and maintained under nor- Specify 1 -Inch NPT (DN25) Model 4. Reset the Model RSV -1 Valve in ac- mal use and service. This warranty RSV -1 Residential Shut -Off Valve, P/N cordance with the Valve Setting Pro- will expire ten (10) years from date of 52- 540 -1 -001. cedure described in this data sheet. shipment by TFSBP. No warranty is Specify 2 -Inch NPT (DN50) Model given for products or components RSV -1 Residential Shut -Off Valve, P/N Flow Test Procedure manufactured by companies not affili- 52- 540 -1 -002. 1. While there is no water flowing in the ated by ownership with TFSBP or for domestic system, completely open products and components which have Valves with ISO Connections the Drain and Flow Test Connection. been subject to misuse, improper in- Specify ISO Rol (DN25) Model RSV -1 2. While water is flowing, record the stallation, corrosion, or which have Residential Shut -Off Valve, P/N pressure reading on the fire sprin- not been installed, maintained, modi- 52- 540 -1 -011. kler system pressure gauge and fled or repaired in accordance with Specify ISO Rc2 (DN50) Model RSV -1 then applicable Standards of the National hen compare this reading to previ- Residential Shut -Off Valve, P/N ous readings. Fire Protection Association, and /or 52- 540 -1 -204. the standards of any other Authorities If there is a significant decrease Having Jurisdiction. Materials found in pressure since the last time the by TFSBP to be defective shall be ei- pressure reading was taken and this ther repaired or replaced, at TFSBP's decrease is not due to a normally sole option. TFSBP neither assumes, expected drop in the water supply nor authorizes any person to assume pressure, an impairment may exist for it, any other obligation in connec- that shouid be immediately identified tion with the sale of products or parts and corrected. of products. TFSBP shall not be re- 3. Close the Drain and Flow Test Con- sponsible for sprinkler system design nection to allow the Model RSV -1 errors or inaccurate or incomplete in Valve to reset automatically. Automatic formation supplied by Buyer or Buy - resetting occurs within ten seconds. er's representatives. 4. After waiting ten seconds, completely In no event shall TFSBP be liable, in open at least three water outlets in contract, tort, strict liability or under the domestic system and allow these any other legal theory, for inciden outlets to flow simultaneously. tal, indirect, special or consequential damages, including but not limited to If the water outlets flow fully, the labor charges, regardless of whether Model RSV -1 Valve is set and ready TFSBP was informed about the pos- for service. Close the water outlets sibility of such damages, and in no on the domestic system. event shall TFSBP's liability exceed an If the water outlets do not flow fully, amount equal to the sales price. close the Domestic Control Valve The foregoing warranty is made in and verify that there is no flow from lieu of any and all other warranties, the fire sprinkler system piping, such express or implied. including warran- as at the Inspector's Test Connec- ties of merchantability and fitness for tion. Wait a minimum of ten seconds. a particular purpose. Re -open the Domestic Control Valve and then recheck that the domestic This limited warranty sets forth the ex- system water outlets are flowing full. clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. p BB -SC 1©© o © " 2h /2' 1 SL O W CLOSE Approved by: NYC Board & Appeals, Cal. l. # 99 6 -81 81 -SM (175psi ® 720 -83 -SA (350 & 500 psi) BRONZE BUTTERFLY VALVE ONE - PIECE, FULL -PORT PSI rejl THREADED EA THREADED ENDS vat's APPROVED DIMENSIONS , 4 -1/2" Valve Size = _ - - 7 fir ♦��� DIM 1" 1 -1/4" 1 -1/2" 2" 2 -1/2" I ir c (MAX K „ mc () us 7^^ A 2.13 2.6 2.88 3.25 4.13 ik oPE" , ,1 B' 3.16 3.31 3.41 3.63 3.82 P iti yi C 1.56 1.94 2.19 2.75 3.19 B .�.. go ENTRY` i S ��\ D 1.72 2.11 2.38 3.07 3.50 iIi I/ K .66 .73 .73 .79 1.18 C L \ li ••■• d L 83 .90 10 1.41 1.29 M 1.10 1.38 1.61 2.07 2.47 __ ll M - .96 1.28 1.50 1.94 2.32 s ��� iii �% � N - 40 5 2.25 2.00 2.50 2.25 10.00 W ifr w6 1.13 1.25 1.41 1.69 1.75 1--- W ALL DIMENSIONS - INCHES D A Pertains to BB -SC100 only, ' Pertains to BB -SCS02 only. ' M-40 ARE DIMENSIONS USING SCHEDULE 40 � 00 _ � ��^ PIPE BB-SC 100 P ARE USING SCHEDULE 80 Sizes 1", 1-1/4" 1 -1 �2" 2", 2-1/2" �2" s > > N-40 IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE W IS THE WRENCH MAKE -UP LENGTH FEATURES 4 - 1/2" • Slow opening and closing 0 fil _ • Quarter turn operation .."-m- la I>ro Q �I • Water Hammer elimination • Optional internal tamper switch �1 © l% .FM►' \'r\ (Indoor /Outdoor use). , nc( .„ 78 - Signals disc movement ` , l - Factory or Field installation - 10 Amp / 115 VAC -60 Hz .4 � � r • Grooved Ends Available in �! Oa\ _ Sizes 2" and 2 -1/2" C _ MATERIALS LIST ITEM PART MATERIALS ASTM SPEC. D W y 1 Indicator Iron F0008P A 2 Housing ASTM 584 UNS BB -SCSO2 3 Body Bronze C8440 (Includes Switch) 4 Handle Brass ASTM B176 UNS C85800 5 Disk ASTMA276, Stainless Steel Type 304 6 Disk Seal EPDM 7 Switch Housing (BB- SCS02) Aluminum The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and /or material specifications without notice. For the most current information access www.milwaukeevalve.com MILWAUKEE VALVE � � City of Atlantic Beach � � Building Department APPLICATION NUMBER .1 800 Seminole Road (To be assigned by the Building Department.) ;. s) 7 3 Atlantic Beach, Florida 32233 -5445 �� �! z Phone (904) 247 -5826 • Fax (904) 247 -5845 t io E-mail: building- dept @coab.us Date routed: a s / / i a City web -site: http: //www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 9 t Srcl S artment review required Yes No Buildin Applicant: /// / J /ow i21 p%ittl0,✓ Planning & Zoning Tree Administrator Project: k I'%AO (T TEht& Public Works Public Utilities Public Safety Fire Services • h Mli.0 ^', l.„ '�'PF .LY.S!., Y ^'n( S+' °'Ap7 { J» - ! Re ew,fee , 3; `E a: F� . Lts� gl � . ,r;� . = li:, !. pia Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ['Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. • �] pp ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. (Denied. Comments: Reviewed by: Date: i Revised 07/27/10 FEB -15 -2012 22:08 FROM: TO:93538486 P.1/1 FIRE HYDRANT MAINTENANCE REPORT DATE: 2-169 - /2 ITME: g'p.s*-r HYDRANT # . HYDRANT LOCATION: Off! It i -2d Tip 96' C) 3, s HYDRANT FLOW TEST: HYDRANT STATIC PRESSURE 41 HYDRANT RESIDUAL PRESSURE 40 P..1 HYDRANT GPM j 04,0 MINUTES FLUSHED PORT Sm ."- GALLONS LOST _._ HYDRANT CONDITION: PAINT /p r.%' CAPS ' c's7 THREADS GREASED 4 HYDRANT BRAND AND SITE HYDRANT VALVE (check to see if open all the way) COMMENTS INSPECTED BY /Ace .r. _4 _ MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH lT@LE0 d [E 800 Seminole Rd Atlantic Beach, FL 32233 I Ph (904) 247 -5826 Fax (904) 247 -5845 Liu gO-B 2 1 2012 JOB ADDRESS: /(e 9- ` j- e-'21--t �� _ 2-6 PROJECT VALUE $ C1-h 3 0(�' ( 000) NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity / (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number • Mechanical Company PA - 7. Woo). 1 z rPke ;of\ Office Phone gt 353 -�/b 9 bL1 ss .-. - 1 . 4i.q Co. Address: Sat 5 TaY� 1Zrxzk Sel ..,,,,Ile Ft 3 "22.26 City State Zip License Holder (Print): -' - " 6C?. Vt v State Certification/Registration # 2 3'i 36300014)03 Notarized Signature of License Holder _ 20 1 �N' Sworn and subscribed before me his VONDA K. DUGGAN s ' day o Notary Public, State of Honda Q �� 14147 � 8, My Comm. Expires Aug n ature of Notary Public irv&dr,__- �R;.. i Commission No. EE 108440