Loading...
Permit Fire Sprinkler 96 W 3rd St 2012 fA CITY OF ATLANTIC BEACH it . s? 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 App on Number 11- 00002602 Date 2/22/12 Dr part -y address _ 96 lei 3 QT RE number . . 170833 -0000- - NCR OLD ACCOUNT NUMBERS . . Application type description SINGLE FAMILY ATTACHED DWELLING Subdivision Name Property Use Property Zoning TO BE UPDATED Application valuation . . . 80000 Owner Contractor BEACHES HABITAT BEACHES HABITAT 1671 FRANCIS AVE. 1671 FRANCIS AVENUE ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241 -1222 (904) 241 -1222 Structure Information 000 000 Construction Type . . . . . TYPE 5 -B Occupancy Type RESIDENTIAL Flood Zone ZONE X Other struct info SQUARE FOOTAGE 1509.00 Permit MECHANICAL FIRE SPRINKLER Additional desc . Sub Contractor . MILTON J WOOD FIRE PROTECTION Permit Fee . . . 85.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date . . 2/22/12 Qty Unit Charge Per Extension BASE FEE 55.00 1.00 30.0000 EA M FIRE SPRKL 1ST 40 HEADS 30.00 Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONA1 ELECTRIC CODE WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Since on -site storage is required, a post construction topographic survey documenting proper construction will be required, prior to issuance of C.O. Full right -of -way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City right -of -way. Call Public Works (247 -5834) for Erosion and Sediment Control Inspection prior to the start of construction. Other Fees STATE DCA SURCHARGE 6.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. r :r' , S r 1,; , - ,� , �\ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Aryl i rat i nn TTiimhar Page 2 i 1 -nQnQ) (- ) Tits? 7/22/12 Other Fees DEV REVIEW - SINGLE & 2 -FAM 50.00 ENG REV RESIDENTIAL BLD 100.00 STATE ELEC DCA SURCHARGE 2.00 STATE MECH DCA SURCHARGE 2.00 STATE PLBG DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 STATE PLBG DBPR SURCHARGE 2.00 STATE DBPR SURCHARGE 6.00 SEWER SDC- SYSTEM DEV CHG 4050.00 UTIL REV RESIDENTIAL BLDG 50.00 WATER CONNECT /METER ONLY 185.00 WATER CROSS CONNECTION 50.00 WATER SDC- SYSTEM DEV CHG 1140.00 Fee summary Charged Paid Credited Due Permit Fee Total 85.00 85.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5649.00 5649.00 .00 .00 Grand Total 5734.00 5734.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. - ��ir� City of Atlantic Beac c APPLICATION NUMBER J1 r� Building Department (To be assigned by the Building Department.) 800 Seminole Road // _ 01 4 3 0 .y v �.• Atlantic Beach, Florida 32233 -5445 Phone (904) 247 -5826 • Fax (904) 247 -5845 -1 ' ust1>� E -mail: building- dept @coab.us Date routed: �o? //a City web -site: http: / /www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 98 ',Q jr Department review required Yes No ui m Applicant: al/7 j M4 fi,e1 7 d Planning & Zoning Tree Administrator Project: /iel. /'`/'1 /Er Jyl& Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco — – Other: APPL ATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circl ne.) Comments: BUILDING ,„.) PLANN G & ZONING -7 ZZ I L Reviewed by: ` y Date: TREE ADMIN. O Second Review: ['Approved as revised. /Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ['Denied. Comments: Reviewed by: Date: I Revised 07/27/10 MECHANICAL PERMIT APPLICATION '° CITY OF ATLANTIC BEACH ; iT @ 11 J7 1 800 Seminole Rd Atlantic Beach, FL 32233 (� 1 2012 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: Qf S J tf42st ` r , . - P By • .,R_ -- Zit °3 PROJECT VALUE $ L mC (,--t-1/4../ ( oco) NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity ( (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company fv ko/\ -) \, cm9 -F, ` ;nec , v,\ Office Phone 964-153-1055 Fax qny - 353 — 64 15 /... Co. Address: 3g05 Far P- C - , -- acil a p oi lle i Ti... 3:42. City State Zip License Holder (Print): A'0-4cb p / IJ Cr.Id JI c- State Certification/Registration # 2 343L3cooi 2003 Notarized Signature of License Holder — — "' ", , VONDA K. DUGG A Sworn and subscribed before me his , Y day of b 2013- •, I. Notary Public, State of i n ure of Notary Public al d t ai _�.� My Comm. Expires Aug. ,44., f • Commission No. EE 108440 FEB -15 -2012 22:08 FROM: TO:93538486 P.1/1 FERE HYDRANT MAINTENANCE REPORT DATE: 2-/G9 -12 TnmE: 9 , HYDRANT # HYDRANT 96, 96' (g s-r HYDRANT FLOW TEST: HYDRANT STATIC PRESSURE _ 4-, Dye HYDRANT RESIDUAL PRESSURE ¢o Ps1 HYDRANT GPM ,; 0 l,, MINUTES FLUSHED PORT SIZE GALLONS LOST HYDRANT CONDITION: PAINT 1p CAPS 60e T}IREADS GREASED HYDRANT BRAND AND SIZE HYDRANT VALVE (check to see if open all the way) COMMENTS INSPECTED BY 4 r (i I Habitat for Humanity 96 & 98 West 3rd Street Fire Protection Project Submittal Package FILE COPY GITV dF A ING OF E1�� kc" 6Ukto va 22IF eY• efol..-- 1 C f11^1 V i MILTON J. WOOD FIRE PROTECTION Milton J. Wood Fire Protection Inc. 3805 Faye Road, Jacksonville, FL 32226 (904) 353 -4055 / (904) 353 -8486 FAX A1.1110 1111. 810011010 • III VW ANII• 41111111111111111111MMIll 1.01 AMYL NNW. ,IIIMONOMMINA•1111116 Fire Protection by Computer Design Society of Fire Protection Engineers (SFPE) Northeast Florida Chapter 904 - 353 -4055 Job Name : 96 -98 W. 3rd Street Building Location : 96 & 98 West 3rd St., Atlantic Beach, Florida 32233 Remote Area : Contract Data File : SFPE - Habitat- 02.wxf Asw Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Society of Fire Protection Page 1 96 -98 W. 3rd Street Date 01/27/2012 HYDRAULIC DESIGN INFORMATION SHEET ame - Habitat for Humanities Date - 02 -16 -12 Location - 96 & 98 West 3rd St., Atlantic Beach, Florida 32233 Building - System No. - Contractor - Society Fire Protection Engineers SFPE Contract No. - Calculated By - Joshua Roman Drawing No. - Construction: ( ) Combustible ( ) Non - Combustible Ceiling Height 8' -0" OCCUPANCY - 1 & 2 Family Dwellings - Residential S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 ( )2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 14 Gpm System Type Listed Pres. at Start Point - 8.2 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 5 Gpm Make Victaulic Model V27 I Elevation at Highest Outlet - 8' -8 "Feet Size 1/2" (7/16 ") K- Factor 4.9 G Note: Temperature Rating 155 ° F N Calculation Gpm Required 33.25 Psi Required 39.79 At Source Summary C- Factor Used: Overhead 150 Underground 150 Water Flow Test: Pump Data: Tank or Reservoir: . Date of Test - 02/16/2012 Rated Cap. Cap. T Time of Test - 9:OOam @ Psi Elev. E Static (Psi) - 48 Elev. R Residual (Psi) - 40 Other Well Flow (Gpm) - 1060 Proof Flow Gpm S Elevation - 1 P Location: 96 & 98 West 3rd Street, Atlantic Beach, Florida 32233 P L Source of Information: City of Atlantic Beach Utilities Department Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 N N O - N ti N fir` r(D ' O LC) 0 LO .V O �NI� Nr , M M O Mad O O M M co m .. d 0 a) - C N CO O � -o a) cu_ 2 c c - o °- E E E ' m coo as >, ill (/)v)u)Y ' u. NN OM its (1300020U) • E - a) 0 r co . o co . O o Q CO j . _ Z • E as r _ a c O ,_ 'o v a) • r O • cC • U • C �. U LC) a) • (0 3 O T • O< 1 Z .0 E 2 0 • O m - W 2 o_ •o •o 5 o o_ E 0 0 • • O O o o . (0 c0 0 0 L :o c a) • co U o a) Q °ga .. coots a) v m WCC 0 � � 0 0 L ' (/) p O0O L. >, 5 >-, 0 0 0 0 0 0 _ 1.0 V M n N N 0 0 0 0 0 0 0 0 0 0 CU 5 CU a) rn U rn co N- co LC) Cr CO N r 0 rn d W Q co U) 0 Q W N N CO e- 0 0 c- 0 N I- O o O 41110. N N U) �00•- r M O m Lo 0 .,•- NC X000 al (O CL CI tD 0 A- co O O o nr to - co N- OOf- N N- co .- N (DOOCO 0 N O .-- N U)00 N- co CO n- c• O 0 C 0 0 co A- C+)OO 0 N u) Z Co e NOON E W L a V 0 N O O N C 0 CO • CO O O C Aft. 0 r M I∎ A. E L� T. N Cr 0 O LY _ U v� tco v s c (0 C N • (C) = (O c •0 o O 0 N o _ O (O .O- .-- O O) LL A 0 0 L > a C _. LL. N LO C -1- -- c '�- Q) � ' o O 0 ( O C I U a) o N N N N N Q �' N • V m OCACOCO co V N V co c) CO E 0 7 co co) O O L 0)4- 3 N J J O U C O L (0 O • M V 0 CO CO CD - 0 j C _ V) C P E2 4) U CL X x C N O N _0U) Ls u - ca - O N O N — C w m m= "- .c E 3 E as a A- N 0 LO (1) 0_ CO _C ( 3 * - E • .+ "0 f0 , p F2 m (0 43 C a) _c O U c c 0 Q - ) =Y a3 0 n N C 0 r- Mnr m fn N V) •_ a.)0 to C . N 0 Q N E N a) Q Y • A- -L c) c co L.L. L CLLD0_ �"0 c a E as ic irs > " 0 w 0 p 0 C C 0 f. m N N F - O C (O f6 a to N *• O •- N 1 2 CO O- ` COt� 4=r fn to L Cti E C cO >>_ t w > 3 3 N 0 (O O c a � Z c 3 2 p v - r- Y t c�a > Q ,_ 0 N w N a CD = 0 U 7 O) E N rn U 0 W ° o C to c = > - N a) ` C) u) C > 0 2U) � f n �rn H M N Z' N . r4) J CYO co Q O u. I 'a D E a 3 a>> a Y c U E C a) >, N cn c N LL oLLadu. �'C_ ,C U cn O O ZLLZ00Z�i 7 � 2 = N a) U � � J > N� LL j 0•� --LL rn m E C� �• N Q - -9 U c s s al C p . -. 3 r.. L LL fn a:< LU L D 5 JLL_ d - ZW O u N Pressure / Flow Summary - STANDARD Society of Fire Protection Page 4 96 -98 W. 3rd Street Date 01/27/2012 ode Elevation K -Fact Pt Pn Flow Density Area Press Actual Actual Req. 1 8.167 4.9 8.2 na 14.03 0.05 256 8.2 3 8.167 4.9 8.42 na 14.22 0.05 256 8.2 2 8.667 8.39 na 4 8.667 11.15 na TOR 8.667 11.58 na BOR 1.0 19.71 na 5.0 UG1 -2.0 38.2 na UG2 -2.0 41.09 na UG3 -2.0 41.09 na SRC 1.0 39.79 na The maximum velocity is 6.99 and it occurs in the pipe between nodes BOR and UG1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams Society of Fire Protection Page 5 96 -98 W. 3rd Street Date 01/27/2012 400"` Hyd. Qa Dia. Fitting Pipe Pt Pt ef. "C" or Ftng's Pe Pv * * * * * ** Notes * * * * ** Point Qt Pf /Ft Eqv. Ln. Total Pf Pn 1 14.03 1.394 2N 16.0 14.042 8.200 K Factor = 4.90 to 150.0 10 6.0 22.000 -0.217 2 14.03 0.0112 0.0 36.042 0.404 Vel = 2.95 0.0 14.03 8.387 K Factor = 4.84 3 14.22 1.394 1N 8.0 1.833 8.422 K Factor = 4.90 to 150.0 10 6.0 14.000 -0.217 2 14.22 0.0115 0.0 15.833 0.182 Vel = 2.99 2 14.03 1.394 3N 24.0 37.583 8.387 to 150.0 10 6.0 30.000 0.0 4 28.25 0.0409 0.0 67.583 2.761 Vel = 5.94 4 0.0 1.394 1N 8.0 2.625 11.148 to 150.0 0.0 8.000 0.0 TOR 28.25 0.0408 0.0 10.625 0.434 Vel = 5.94 TOR 0.0 1.394 2Fsp 0.0 7.500 11.582 to 150.0 0.0 0.0 7.821 * Fixed loss = 4.5 BOR 28.25 0.0408 0.0 7.500 0.306 Vel = 5.94 BOR 5.00 1.394 1E 4.762 134.000 19.709 Qa = 5.00 to 150.0 1T 9.523 14.284 10.306 * Fixed loss = 9.007 UG1 33.25 0.0552 1Zik 0.0 148.284 8.189 Vel = 6.99 00 0.0 1.598 2T 23.312 37.000 38.204 150.0 0.0 11.656 1.500 * Fixed loss = 1.5 UG2 33.25 0.0284 0.0 48.656 1.382 Vel = 5.32 UG2 0.0 8.425 0.0 15.000 41.086 to 140.0 0.0 0.0 0.0 UG3 33.25 0.0 0.0 15.000 0.0 Vel = 0.19 UG3 0.0 6.275 1E 21.977 15.000 41.086 to 140.0 1G 4.709 73.780 -1.299 SRC 33.25 0.0 1T 47.094 88.780 0.004 Vel = 0.34 0.0 33.25 39.791 K Factor = 5.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqCt7/ & Building Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Technical Tyco CPVC Pipe and Fittings pro- Data duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively Sizes for use in wet pipe automatic fire sprin- 3/4" to 3" • kler systems. The Tyco CPVC Pipe Maximum Working Pressure and Fittings are produced from Blaze- 175 psi Master® CPVC compound that is a specially developed thermoplastic Approvals compound composed of post chlorin- UL, FM, C -UL, NSF, LPCB, MEA, and ated polyvinyl chloride (CPVC) resin the City of Los Angeles. (Refer to In- ` Au* and state of the art additives. Tyco stallation Handbook IH -1900 dated � CPVC Pipe and Fittings are easier to June 2008 for exact listing /approval install than traditional steel pipe sys- information.) tems, and at the same time, provide Manufacture Source superior heat resistance and strength U.S.A. as compared to traditional CPVC and PVC piping materials used in the Material plumbing trade. Various adapters are • Pipe: ASTM F442, SDR 13.5 available to connect CPVC pipe to me- tallic piping. All female pipe thread • Fittings: ASTM F438 (Sch. 40) and adapters have brass inserts for dura- ASTM F439 (Sch. 80), ASTM F1970 bility. Grooved adapters connect di- Color rectly to grooved end valves and me- Orange tallic pipe, with flexible grooved end couplings. NOTICE Tyco® CPVC Pipe and Fittings pro- duced with BlazeMaster® CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler ,low manufacturer should be contacted with any questions. BlazeMaster® is a registered trademark of The Lubrizol Corporation Page 1 of 2 JUNE, 2008 TFP1915 Two -Hole Side Mount CPVC Pipe Straps Application: The Two -Hole Side Mount CPVC Pipe Strap is designed to support pipe running perpendicular to the beam. When attached to the bottom of the beam it supports! 3' *4 the pipe, but when attached to the top of the beam it will only act as a guide. Features: , • Beveled edges protects CPVC pipe from damage 0Pd - • Easily attaches to wood structure with included screws or to minimum 20 gauge steel with special screws (sold separately) • Retaining dimples simplify installation process • Strap is UL Listed (20 • Sizes: 3 /4" (19mm) through 2" (50mm) CPVC pipe LISTED • Includes: one (1) pipe strap and two (2) #10 x 1 hex head screws Optional: 1 /4" x 1" (25.4mm) tek type screw for mounting to steel (sold separately) • Strap has two (2) 1 /4" (6.3mm) diameter hole for mounting • Material: 20 gauge (0.9mm) X 1 (28.6mm) pre - galvanized steel UPC Part D Nominal W C HC Maximum Wt. Number Number Pipe Dia. Overall Spacing Per 100 in. mm in. mm in. mm in. mm in. mm lbs. kg 78205160075 B3183 - 3 /4 1.050 26.7 2 58.7 1 43.8 1 47.6 66 1676 9.0 4.1 78205160076 _ _ B3183 -1 1.315 33. 29/16 65.1 1 49.2 2 55.6 72 1829 10.0 4.5 Aws- 78205160077 B3183-1 1.660 42.1 2 74.6 2 58.7 2 63.5 78 1981 11.0 5.0 78205160078 B3183 -11/2 1.900 48.2 3 82.5 25/8 66.7 2 71.4 84 2133 1 2.0 5.4 78205160079 B3183 - 2 2.375 60.3 3 92.1 3 76.2 3 82.5 96 2438 13.0 5.9 Nominal Pipe W Diameter `_ D Support Application C Guide Application 1 ---_______, 6 � J �z p" .� � '� WO r ..,..,,.., Fos _....,;:„., hr.") �� .: ,.., \ !:-; „,, , , , iffil - ' Perpendicular pipe run Perpendicular pipe run bottom mounted on wood joist top mounted on wood joist oumk- COOPER B - Line One -Hole Wrap Around CPVC Pipe Straps Application: The One -Hole Wrap Around CPVC Pipe Strap is designed to support pipe running horizontally on the side of a beam. It can also be used, as a guide, to mount CPVC pipe that runs perpendicular across the top of a beam or on a vertical pipe run. _ Features: " t ' • Beveled edges protects CPVC pipe from damage • Easily attaches to wood structure with included screws or to minimum _' 20 gauge steel with special screws (sold separately) • Strap is UL Listed j�'� • Sizes: 3 /4" (19mm) through 2" (50mm) CPVC pipe �, • Includes: one (1) each pipe strap and #10 x 1 hex head screw LISTED Optional: 1 /4" x 1" (25.4mm) tek type screw for mounting to steel (sold separately) • Strap has one (1) 1 /4" (6.3mm) diameter hole for mounting • Material: 20 gauge (0.9mm) x 1 (28.6mm) pre - galvanized steel UPC Part D Nominal L C Maximum Wt. Number Number Pipe Dia. Overall Spacing Per 100 in. mm in. mm in. mm in. mm lbs. kg 78205160064 B3181 - 1.050 26.7 2 60.3 1 34.9 66 1676 9.0 4.1 78205160065 B3181 - 1.315 33.4 25/8 66.7 1 36.5 72 1829 10.0 4.5 78205160066 B3181-1 1.660 42.1 2 47.6 1 39.7 78 1981 12.0 5.4 78205160067 83181 -1 1.900 48.2 31/16 77.8 1 41.3 84 2133 12.0 5.4 78205160068 B3181 - 2.375 60.3 3 87.3 1 46.0 96 2438 15.0 6.8 Support Application Nominal Pipe Diameter : ' ''' ' ' ' : ' „:;;OteSaft, ,''' 41' 41 Akk-‘1' ----,- c ,;,-,;„*.01,,,,,,,,„:,,,„ ? ,....vo, - --,All* , i y � �� Guide Applications Horizontally mount CPVC pipe Running CPVC pipe vertically Running CPVC pipe perpendicular across top of beam COOPER B - Line FIRE PROTECTION PRQDUCTS AUTOMATIC SPRINKLEJ3S (142 V27, K4.9 ® SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 These Model V27 residential sprinklers are designed to meet the requirements of NFPA 13, 13D,` py and 13R for residential use in a variety of room sizes, depending upon available operating pressure and room configuration. Model V2734 is UL Listed for use under smooth flat horizontal ceilings and sloped ceilings up to and including 8/12 (33.7 °) pitch. The design incorporates state -of- the -art, heat responsive, frangible glass bulb design (quick response) for prompt, DOME COVER PLATE precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex - shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various finishes to meet many design requirements. The V27 sprinklers are now available with the aesthetically pleasing dome cover plate, which also is available in various finishes to meet many design requirements. SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire COVERAGE: Residential spray coverage up to 20 feet x 20 feet (6.1 m x 6.1 m) room sizes per NFPA. • TECHNICAL SPECIFICATIONS: Models: V2734, V2736 ACCESSORIES Style: Concealed Residential Pendent Installation Wrench: Nominal Orifice Size: � /i6 " /12mm • Concealed: V39 K- Factor: Finishes: • V2734 — 4.9 Imp. /7.1 S.I.^ for room sizes • Chrome plated up to 1674.9m. • White painted • V2736 — 4.9 Imp. /7.1 S.I.^ for room sizes • Flat black 18' to 2075.5 and 6.1m. • Custom painted Nominal Thread Size:' " NPT /15mm For cabinets and other accessories refer to Max. Working Pressure: 175 psi /1200kPa separate sheet. Factory Hydrostatic Test: 100% @ 500 psi /3450kPa ^ For K- Factor when pressure is measured in Min. Operating Pressure: 7psi /48kPa Bar, multiply S.I. units by 10.0. Temperature Rating: See chart on page 2. * Teflon is a registered trademark of Dupont Co. MATERIAL SPECIFICATIONS Pendent Deflector: Bronze per UNS 051000 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: • Quick Response: 3.0mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Seal: Teflon* tape Frame: Die cast brass 65 -30 Cup: Cold rolled steel, zinc - chrome plated. Cover /Escutcheon: Brass per UNS C26000 JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para tiOw Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA iCtbllulic' REV_E 40.42_1 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40 A"" V27, K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 RATINGS All glass bulbs are rated for temperatures from —67 °F ( -55 °C) up to those shown in table below. SPRINKLER — V2734/V2736 COVER — V27 Sprinkler Temperature — °F / °C Cover Temperature — °F / °C Maximum Maximum Sprinkler Victaulic Nominal Ambient Victaulic Nominal Ambient Temperature Part Temperature Temperature Glass Bulb Part Temperature Temperature Classification Identification Rating Allowed Color Identification Rating Allowed 155 100 Red A 135 100 ..,Ordinary C 68 38 57 38 *A for use with Standard or Quick Response Concealed Sprinklers 135 °F (57 °C) or 155°F (68 °C). • Proper temperature rated cover must be used with the correct sprinkler rating per the Temperature Chart Ratings. • The plastic shipping cap must be removed for the sprinkler to operate properly. • If shipping cap is replaced over an installed sprinkler for purposes of painting or plastering, then the fire protection system shall be considered out of service, the Authority Having Jurisdiction notified, and a firewatch is suggested. Failure to do so may result in failure of sprinkler to operate causing serious personal injury or property damage. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K- Factor Thread Size Quantity Cover Finish Wrench Model Number 1 ! www.victaulic.com rctaUI G VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA .._ . _....,,.,u,._.,..,,..,.�..�. REV _E 40.42_3 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.42 r V27, K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 ROOM SIZE Installed Under Smooth Rat Horizontal Ceilings up to 2/12 (9.5 °) Pitch Minimum Flow per Sprinkler Min. Nominal for Horizontal Ceilings Installation K- Factor Maximum 2/12 (9.5 °) Pitch Room Size Spacing Imperial For NFPA 13R or 130* Model Feet /meters Feet /meters S.I.^ GPM /LPM @ PSI /kPa • • V2734 ` 12x12 8.0 J 4.9 13 GPM @7.OPSI 3.7 x 3.7 1 2.4 I 7.1 49.2 LPM @ 48.5 kPa V2734 14x14 8.0 4.9 i 13GPM @7.0P9 4.3 x 4.3 f 2.4 7.1 1 49.2 LPM @ 48.5 kPa 16x16 8.0 • 4.9 i 14GPM @8.2PSI V2734 4.9 x 4.9 < 2.4 7.1 53.0LPM @57.OkPa V2736 1 12 x 12 1 8.0 4.9 13GPM @7.OPSI 3.7x3.7 I 2.4 7.1 49.2 LPM @ 48.5 kPa V2736 ) 14 x 14 i 8.0 1 4.9 17 GPM @ 12.0PSI 4.3 x 4.3 2.4 I 7.1 64.3 LPM @ 83.0 kPa V2736 16 x 16 .w � 8.0 4.9 17 GPM @ 12.0 P51 4.9x4.9 1 2.4 Z1 64.3 LPM @83.OkPa V2736 18 x 18 8.0 € 4.9 17 GPM @ 12.0 PSI 5.5 x 55 2.4 ! 7.1 643 LPM @ 83.0 kPa V2736 20 x 20 8.0 4.9 1 20GPM @ 16.7 PSI __ 6.1 x 6.1 2.4 I 7.1 75.7 LPM @ 114.9 kPa Installed Under Sloped Ceilings up to 4/12 (18.4 °) Pitch Minimum Flow per Sprinkler Min. Nominal for Sloped Ceilings Installation K- Factor Maximum 4/12 (18.4 °) Pitch Room Size Spacing Imperial For NFPA 13R or 130* Model Feet /meters Feet /meters S.I.^ GPM /LPM @ PSI/1(Pa V2734 1 12 x 12 8.0 4.9 19GPM @ 15 PSI . 3.7 x 3.7 2.4 7.1 71.9 LPM @ 103.0 kPa 14x 14 8.0 1 49 19GPM@ 15P51 V2734 43 x 43 2.4 7.1 71.9LPM @ 103.OkPa 19 V2734 16 x 16 8.0 4.9 i GPM @ 15 PSI 1 4.9x49 2.4 € 7.1 71 kPa - 12 x 12 8.0 4.9 21 GPM @ 185 P51 V2736 3.7 x 3.7 1 2.4 1 7.1 795 LPM @ 128.0 kPa V2736 I 14 x 14 aim 8.0 € 4.9 21 GPM @ 18.5 P51 »µ _ 4.3_x 4.3 _ 2.4 _ s 7.1 1 79.5LPM @ 128.0 kPa .._ ._ @ 18.5 _._. V2736 }_ 16 x 16 1 8.0 1 4.9 21 GPM @ 18.5 PSI - 4.9 X49 1. . .._........2.4... ._......... 7.1 795 LPM @ 128.0 kPa V2736 1 18 x 18 8.0 1 4.9 21 GPM @ 185P51 1 5.5 x 55 2.4 1 7.1 1 79.5 LPM @ 128.0 kPa V2735 I 20 x 20 8.0 4.9 € 28GPM @ 32.6P51 6.1x6.1 2.4 7.1 106.O LPM @225.OkPa Installed Under Sloped Ceilings up to 8/12 (33.7 °) Pitch Minimum Flow per Sprinkler Min. Nominal tor Sloped Ceilings Installation K- Factor Maximum 8/12 (33.71 Pitch Room Size Spacing Imperial For NFPA 13R or 130` Model Feet/meters Feet /meters S.I.^ GPM/LPM @ PSI /kPa V2734 i 12 x 12 8. 4.9 21 GPM @ 18.4 PSI 3.7 x 3.7 24 7.1 79.5 LPM @127.OkPa V2734 14 x 14 8.0 4.9 21 GPM @ 18.4 851 4.3 x4.3 2.4 7.1 79.5 LPM @127.0kPa : V2734 16 x 16 8.0 4.9 21 GPM @1 8.4PSI 4.9 x 4.9 2.4 7.1 79.5 LPM @ 127.0 kPa V2736 12 x 12 8.0 4.9 - 3.7 x 3.7 2.4 7.1 - V2736 1 14 x 14 8.0 4.9 4.3x4.3 2.4 7.1 - V2736 16 x 16 8.0 4.9 - 4.9 x 4.9 2.4 7.1 - V2736 i 18 x 18 8.0 4.9 5.5x55 2.4 7 - - V2736 !i 20 x 20 8 0 4.9 6.1 x 6.1 2 7 r www.victaulic.com \iCtaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA - -- - - - -- - - - -- REV _E 40.42_5 FIRE PROTECTION PRODUCTS – AUTOMATIC SPRINKLERS 40.42 /" V27, K4.9 Residential Concealed Pendent and Specific Application (Flat & Sloped Ceilings) Quick Response V2734 and V2736 NORMAL WETTING PATTERNS MODEL V2736 K4.9 RESIDENTIAL CONCEALED 13 GPM (49.2 LPM) „-.,, - * .. ,.....,.«.. g ...... - * ..._................ — _ ” tam ,,,, .......... L J -„ T y o 6 Te 5 j F 12m P 09 2 TM 6 ... 2 0 ,b. 0.8",‘ - mum um MOM 1 12m 03 > - Ob 2 o, CL OP, R y NOMINAL WETTING PATTERN 12' x 12' COVERAGE AREA MODEL V2736 K4.9 RESIDENTIAL CONCEALED 17 GPM (64.3 LPM) z4 r:,,,...„ -- 2.1 m . " "`aa, t. ' , 6 € 09 Obm ' 6 2Am 18m 12m Ob B'0Am I 03 , s t2 4 OF ROOM > NOMINAL WETTING PATTERN 18' x 18' COVERAGE AREA MODEL V2736 K4.9 RESIDENTIAL PENDENT AND RECESSED PENDENT 20 GPM (75.7 LPM) 2 .4 m i - ,._...... __..,. ., .. __. ... ,,, 1 1 , } 2 b g I. 1 , 0.8m B2Am 24m I.Bm 12m Obm I 1 4 ibm I 4 0.3m ;,.z - I2m C0F NOMINAL WETTING PATTERN 20' x 20' COVERAGE AREA NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall - wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. 1,16" Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com jctblulic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA REV _E 40.427 - tqco Fire Suppression & Building Products tr rapid response® HOME FIRE SPRINKLER SYSTEM Technical Services 800 - 381 -9312 I +1- 401 - 781 -8220 www.tyco - fire.com Model RSV -1 Residential Shut -Off Valve 1 Inch and 2 Inch (DN25 and DN50) for Dual - Purpose Residential Water Supply General NOTICE The Model RSV -1 Residential Shut -Off D escription Valves described herein must be installed and maintained in compliance with this The TYCO RAPID RESPONSE Model document, as well as with the applicable E: RSV -1 Residential Shut -Off Valves standards of the National Fire Protection f are intended for use in dual-purpose Association, in addition to the standards , residential water supply piping that of any authorities having jurisdiction. serves both domestic and residential Failure to do so may impair the integrity , r ' - fire protection sprinkler system needs. of this device. % - The 1 -Inch (DN25) Valve is intended - / " for NFPA 13D system needs, whereas Owners are responsible for maintaining, N the 2 -Inch (DN50) Valve is intended for their fire protection system and devices in systems designed in accordance with proper operating condition. The installing either NFPA 13D or NFPA 13R. contractor or sprinkler manufacturer should be contacted relative to any ,► When a fire sprinkler operates, the questions. Physical Characteristics Model RSV -1 Residential Shut -Off Refer to Figures 3 and 4. Valve automatically shuts off water flow to the domestic system and di- ■ T echnical • 1 - Inch (DN25) Valve verts the available water supply to the Body Copper Alloy fire sprinkler system. Consequently, D ata Top and when the Model RSV -1 Valve is uti- Bottom Cover Copper Alloy lized, the system designer does not Approvals Upper Cap Brass need to add the domestic flow de- • The 1 -Inch (DN25) Model RSV -1 Resi- Bottom Seal Brass mand to the fire sprinkler system flow dential Shut -Off Valve is UL and C -UL Piston Glass Reinforced demand, as would otherwise be re- Listed and NSF -61 Annex G Approved. Polyphenylene Oxide quired by NFPA 13R. It is suitable for use in water supply Differential Consider use of the Model RSV -1 arrangements for residential fire sprin- Ring Glass Reinforced Residential Shut Off Valve when either kler systems designed per NFPA 13D. Polyphenylene Oxide the water supply cannot adequately • The 2 -Inch (DN50) Model RSV -1 Resi- Sleeve Glass Reinforced provide for both the domestic design dential Shut -Off Valve is UL and C -UL Polyphenylene Oxide demand and the fire sprinkler flow de- Listed and NSF -61 Annex G Approved. Upper and mand, or it is necessary to increase It is suitable for use in water supply Lower Seals EPDM the effectiveness of the fire sprinkler arrangements for residential fire sprin- 0-Rings Buna -N system by automatically shutting off kler systems designed per NFPA 13D Piston Spring Stainless Steel the domestic flow. or 13R. Piston Screws Stainless Steel The Model RSV -1 Residential Shut- Maximum Pressure Cap Screw Stainless Steel Off Valve maximizes the effective use 175 psi (12,1 bar) • 2 - Inch (DN50) Valve of an existing water supply. Therefore, Body and in areas with limited water supplies, it Weight Cover Copper Alloy may eliminate the need to acid costly 1 -Inch (DN25): 11 lbs. (5 kg) Piston Insert Copper Alloy pumps, pressurized reservoirs, or elec- 2 -Inch (DN50): 29 lbs. (11 kg) Bottom Seal Copper Alloy trically operated domestic shut -off valves. The Model RSV -1 Valve has a Pressure Loss Piston Cover .... Glass Reinforced built -in check valve in the fire sprinkler Refer to Figures 7 and 8. Polyphenylene Oxide system outlet that eliminates the need Insert Sleeve .... Glass Reinforced for a separate check valve. Also, the Patents Polyphenylene Oxide Model RSV -1 Valve automatically re- 2 -Inch (DN50) Model RSV -1 Valve: Piston Seal EPDM Ow sets, thereby eliminating the need for Patent Pending O -Rings EPDM valve disassembly after a fire sprinkler Piston Spring Stainless Steel system test or operation. Piston Nut Stainless Steel Retainer Ring Stainless Steel Page 1 of 8 DECEMBER 2010 TFP980 TFP980 Page3of8 0.. Operating Principles 3 -5/8" DIA. FIRE Components: (92,1 mm) r SPRINKLER ORT, 1" NPT PORT, a fire sprinkler activates dur- 1 - Body ing domestic usage, the TYCO Model 2 - Top Cover 2 RSV -1 Residential Shut -Off Valve 3 - Screw, � automatically shuts off flow to the U pper Cap 5 I a ` D OMESTIC domestic system and diverts the avail- 4 - Upper Cap 3 r� PORT 3 -1/4" able water supply to the fire sprinkler 5 - 0 -Ring, t.ar :r,� �1 (82 mm) system, thereby eliminating a reduced Cover (2) 4 o�� ii% ���2. 1 NPT r m flow condition in the sprinkler system 6 Upper Seal ,w ; that might otherwise be caused by 7 - 0 -Ring, 6 1 ,1111 possible significant domestic water Upper Sleeve 7 � � 1 5 8- 3/16" usage. 8 Sleeve ; ::::::V.:: a i (208,0 mm) ..... When the Model RSV -1 Valve is in the 9 - Spring 8 10 - Differential 4- 15/16" Q ;'g;� ° �� ♦ 10 normal standby position as shown in 9 • ; l I l; :�� 1 11 125,4 mm Figures 7 and 8, the Piston Assembly, R • %`1 s si r (125,4 assisted by its Spring, is in the down 11 - Lower Seal 1 k I 14 position. With the Piston Assembly in 12 - Screw, iB 5 the down position, the Fire Sprinkler Piston (4) 12 Seal permits the Model RSV -1 Valve 13 Bottom Cover 4 d to perform as a conventional check 14 - Piston 13 valve. Also, with the Piston Assembly 15 0-Ring, WATER in the down position, water is avail- Lower Sleeve SUPPLY 2-3/8" able on demand through the Domestic PORT, 1" NPT (60,3 mm) Flow Passage and out the Domestic Port. FIGURE 3 Upon operation and with a mini- 1 -INCH (DN25) MODEL RSV -1 RESIDENTIAL SHUT -OFF VALVE mum design water flow —that is, 12.5 ASSEMBLY AND DIMENSIONS GPM (47,3 LPM) for the 1 -inch Valve ,/11.► or 8 GPM (30,5 LPM) for the 2 -Inch Valve —to the automatic residential fire sprinkler system, the Piston Assembly 5 -3/8" DIA. FIRE moves upward. With the Piston As- (136,5 mm) 1 SPRINKLER sembly in the up position, any water 12 PORT, 2" NPT flow to the Domestic Port is diverted to the Fire Sprinkler Port. 10 The contours of the Piston Assembly 1 C omponents: + DOMESTIC are specifically configured to minimize 1 -god g �� PORT, its upward movement except under Body the level of sustained fire sprinkler 2 - Insert Sleeve Q \ 2" NPT 4-1/2" system flow resulting from operation 3 - Bottom Seal 5 s Y 9 P Q (114,3 mm) of one or more fire sprinklers. How- 4 Piston Cover 11 2 .1� \%,.ecoce ever, because most fire sprinkler sys 5 Piston Seal \� �� ■_■ I .,00 1 4 tems contain air ockets, the Piston 6 Piston Insert g `��/ / , p 7 - Piston S pr i ng 9-1/16" on Assembly tends to move momentarily ��,i i . (230,2 mm) 8 - Piston Nut 2 upward when there is a surge in sup- N.�� 9 - Insert Sleeve ��� ply pressure. 4 `I �����M ` i 1► ` 0 -Ring (2) �1 ► The momentary opening and re -clos- 10 - Cover 0 -Ring g +? 4- 9/16" ing of the Piston Assembly at the Fire 11 - Retainer Ring or (115,9 mm) Sprinkler Line Seal traps a portion 12 - Cover 3 6141/ors k of the pressure increase within the 13 - Bottom Seal _ a fire sprinkler system. Trapped pres- 0 -Ring 13 aC sure increases within the fire sprinkler 7 system help to prevent a subsequent WATER surge in the supply pressure from 8 SUPPLY 3 -3/4" causing the water -flow detector to sig- PORT, 2" NPT (95,3 mm) nal a false alarm (unless a by -pass is installed per Figure 2). FIGURE 4 2 -INCH (DN50) MODEL RSV -1 RESIDENTIAL SHUT -OFF VALVE ASSEMBLY AND DIMENSIONS ,n011` TFP980 Page 5 of 8 FIRE TO FIRE FIRE SPRINKLER PISTON PISTON SPRINKLERS SPRINKLER PORT ASSEMBLY ASSEMBLY PORT 3\ 1p FIRE FIRE , FIRE 4 SPRINKLER SPRINKLER 4 SPRINKLER m / ir m SEAT SEAT FLOW i tR * dlIIIIIII1 PASSAGE kt M INII��I . DOMESTIC \�= j 114=6,1„.. PORT \1? ���@ TO DOMESTIC �' DOMESTIC +411 III DOMESTIC # a /�I�. 'r -4 ='. FLOW , ', �� INTERNAL �' —'�� �� PORT PASSAGE \ ,!�,,, BY-PASS %e_— — Q , ".., � RESTRICTION it !, N k' ' § DOMESTIC Z 4 \ " J 4�dI1 ► • h SEAT ` �$�� SUPPLY � �� A' '' 'C DOMESTIC 'D' __=— ,, DO ES SUPPLY PORT Li__ SEAT t�� PORT SUPPLY SUPPLY STANDBY OPERATED FIGURE 7 STANDBY AND OPERATED POSITIONS FOR 1 -INCH (DN25) MODEL RSV -1 VALVE TO FIRE FIRE SPRINKLERS FIRE SPRINKLER SPRINKLER PORT PISTON PISTON = � PORT 'Kr • f 4 ASSEMBLY ASSEMBLY y g g'i T FIRE ��� FIRE SPRINKLER FIRE �, SPRINKLER QQ Q� SEAT SPRINKLER aQ Q� FLOW PASSAGE DOMESTIC 6,, N4 1111111 t 6, j S DOMESTIC ►i t i , I' 11 v %;01014•\` DOMESTIC M , i i DOMESTIC \\'5 IIIMMINI1114 terlares if , , FLOW t ' k DOMESTIC � PASS AGE ill \ � q SEAT PORT • W 14 INTERNAL " � SUPPLY -� � RE '� ST RICTION PASS � % � V SUPPLY PORT ' t a ST �i �\'i PORT SUPPLYSUPPLY DOMESTIC SEAT STANDBY OPERATED FIGURE 8 STANDBY AND OPERATED POSITIONS FOR 2 -INCH (DN50) MODEL RSV -1 VALVE TFP980 Page 7 of 8 Operation Test Procedure Limited Ordering 1. Fully open two or three water outlets in the domestic piping system. Warranty Information 2. To simulate a sprinkler operation, open the Alarm Test Connection of Products manufactured by Tyco Contact your local distributor for avail - the fire sprinkler system. Fire Suppression & Building Prod- ability. When placing an order, indi- ucts (TFSBP) are warranted solely to cate the full product name and Part 3. Verify that any alarms are operating the original Buyer for ten (10) years Number (P /N). and that the flow from the domestic against defects in material and work - water outlets decreases to no more manship when paid for and properly Valves with NPT Connections than a trickle. installed and maintained under nor- Specify 1 -Inch NPT (DN25) Model 4. Reset the Model RSV -1 Valve in ac- mal use and service. This warranty RSV -1 Residential Shut -Off Valve, P/N cordance with the Valve Setting Pro- will expire ten (10) years from date of 52- 540 -1 -001. cedure described in this data sheet. shipment by TFSBP. No warranty is Specify 2 -Inch NPT (DN50) Model given for products or components RSV -1 Residential Shut -Off Valve, P/N Flow Test Procedure manufactured by companies not affili- 52- 540 -1 -002. 1. While there is no water flowing in the ated by ownership with TFSBP or for domestic system, completely open products and components which have Valves with ISO Connections the Drain and Flow Test Connection. been subject to misuse, improper in- Specify ISO Rc1 (DN25) Model RSV -1 2. While water is flowing, record the stallation, corrosion, or which have Residential Shut -Off Valve, P/N pressure reading on the fire sprin not been installed, maintained, modi- 52- 540 -1 -011. kier system pressure gauge and fled or repaired in accordance with Specify ISO Rc2 (DN50) Model RSV -1 then compare this reading to previ- applicable Standards of the National Residential Shut -Off Valve, P/N ous readings. Fire Protection Association, and /or 52-540-1-204. the standards of any other Authorities If there is a significant decrease Having Jurisdiction. Materials found in pressure since the last time the by TFSBP to be defective shall be ei- pressure reading was taken and this ther repaired or replaced, at TFSBP's decrease is not due to a normally sole option. TFSBP neither assumes, expected drop in the water supply nor authorizes any person to assume pressure, an impairment may exist for it, any other obligation in connec- that should be immediately identified tion with the sale of products or parts ,►, and corrected. of products. TFSBP shall not be re- 3. Close the Drain and Flow Test Con- sponsible for sprinkler system design nection to allow the Model RSV -1 errors or inaccurate or incomplete in- Valve to reset automatically. Automatic formation supplied by Buyer or Buy resetting occurs within ten seconds. er s representatives. 4. After waiting ten seconds, completely In no event shall TFSBP be liable, in open at least three water outlets in contract, tort, strict liability or under the domestic system and allow these any other legal theory, for inciden outlets to flow simultaneously. tal, indirect, special or consequential damages, including but not limited to If the water outlets flow fully, the labor charges, regardless of whether Model RSV -1 Valve is set and ready TFSBP was informed about the pos- for service. Close the water outlets sibility of such damages, and in no on the domestic system. event shall TFSBP's liability exceed an If the water outlets do not flow fully, amount equal to the sales price. close the Domestic Control Valve The foregoing warranty is made in and verify that there is no flow from lieu of any and all other warranties. the fire sprinkler system piping, such express or implied. including warran- as at the Inspector's Test Connec- ties of merchantability and fitness for tion. Wait a minimum of ten seconds. a particular purpose. Re open the Domestic Control Valve This limited warranty sets forth the ex- and then recheck that the domestic system water outlets are flowing full, clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. i]0©0 0 1' 2 BB-SC �o Approved by: NYC Board of Stds. & Appeals, ® SL 0 W CLOSE 20 83-SA (350 & 500 ps BRONZE BUTTERFLY VALVE ONE - PIECE, FULL -PORT 175 PSI THREADED ENDS APPROVED c s DIMENSIONS 4 - 1/2" �` tit i\ Valve Size - � FM► DIM 1" 1 -1/4" 1 -1/2" 2" 2 -1/2" Irl c ®ut 76° A 2.13 2.63 2.88 3.25 4.13 ( MAX li op ,l B' 3.16 3.31 3.41 3.63 3.82 B ENTRY) W i rt' . D C 1.56 1.94 2.19 2.75 3.19 - wr �� 1.72 2.11 2.38 3.07 3.50 /�II�I�` n `\ D 4.16 4.16 451 4.76 4.66 I i L • .66 .73 .73 .79 1.18 - C I + L � L 83 .90 .10 1.41 1.29 M-40' 1.10 1.38 1.61 2.07 2.47 XVId �` ,` ��, ma. , � M .96 1.28 1.50 1.94 2.32 = • . i �4 i i�i N 2.25 2.00 2.50 2.25 10.00 we 1.13 1.25 1.41 1.69 1.75 W ALL DIMENSIONS - INCHES D A ' Pertains to BB -SC100 only. ' Pertains to BB -SCS02 only. ' M ARE DIMENSIONS USING SCHEDULE 40 BB -SC100 PIPE M ARE DIMENSIONS USING SCHEDULE 80 PIPE Sizes 1", 1-1/4", 1-1/2", 2 ", 2-1/2" 5 N IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 OM' PIPE W IS THE WRENCH MAKE -UP LENGTH FEATURES 4-1/2" • Slow opening and closing 0 0 _ �. • Quarter turn operation • ur 0 • Water Hammer elimination • li m �!�,�� • Optional internal tamper switch 7 0 . • � �� .FM► r (Indoor /Outdoor use). Signals disc movement 111111111161 au ; ea - - Factory or Field installation © � y � II) , l �`i! =� i tari - 10 Amp / 1 15 VAC -60 Hz �y _I 1 - 0.5 Amp / 28 VDC Grooved E e • nds Available in Sizes 2" and 2 -1/2" ` C ■ ,I -- ---W---1 MATERIALS LIST ITEM PART MATERIALS ASTM SPEC. D A 1 Indicator Iron F0008P ASTM 584 UNS BB -SCS02 2 Housing Bronze 3 Body C8440 (Includes Switch) ASTM B176 UNS 4 Handle Brass C85800 ASTM A276, 5 Disk Stainless Steel Type 304 6 Disk Seal EPDM 7 Switch Housing Aluminum 00 (BB- SCS02) The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and /or material specifications without notice. For the most current information access www.milwaukeevalve.com MILWAUKEE VALVE