Loading...
Permit Elevator 1825 Ocean Grove 2011 J ,ak 4 , ' 1 z CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 App - .n Number 12- 00000008 Date 3/21/12 Property Tddre2s 1825 OrEW GROVE DP RE number . . 169602 -1000- - NCR OLD ACCOUNT NUMBERS . . AB19626 Application type description RESIDENTIAL ADDITION Subdivision Name Property Use Property Zoning RES SF DISTRICT Application valuation . . . 80000 Owner Contractor MCCLAIN PRO - BUILDERS OF FLORIDA LLC 1825 OCEAN GROVE DRIVE 1115 OAKS RIDGE DR S ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 386 -0094 - -- Structure Information 000 000 ADDITION RESIDENTIAL Construction Type TYPE 5 -B Occupancy Type RESIDENTIAL Flood Zone ZONE X Permit MECHANICAL ELEVATOR Additional desc . Sub Contractor . FLORIDA ELEVATORS SALES & Permit Fee . . . 155.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 3/21/12 Qty Unit Charge Per Extension BASE FEE 55.00 1.00 100.0000 EA M ELEVATORS 100.00 Special Notes and Comments ELEVATOR FINAL INSPECTION REQUIRED *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONA1 ELECTRIC CODE *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Roll off container company must be on City approved list and container cannot be placed on City right -of -way. Contact Public Works (247 -5834) for Erosion and Sediment Control Inspection prior to the start of construction. Roll off container company must be on City approved list PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. s , ‘ CITY OF ATLANTIC BEACH j Ni...,. 800 SEMINOLE ROAD J ~ =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 ~Jj �� Page 2 a - 21/12 Special Notes and Comments and container cannot be placed on City right -of -way. Contact Public Works (247 -5834) for Erosion and Sediment Control inspection prior to the start of contruction. Other Fees STATE DCA SURCHARGE 6.00 STATE ELEC DCA SURCHARGE 2.70 ENG REV PRE APP > 3 HRS 25.00 STATE MECH DCA SURCHARGE 4.33 STATE PLBG DCA SURCHARGE 2.00 STATE ELEC DBPR SURCHARGE 2.70 STATE MECH DBPR SURCHARGE 4.33 STATE PLBG DBPR SURCHARGE 2.00 STATE DBPR SURCHARGE 6.00 UTIL REV PRE APP >3 HRS 25.00 Fee summary Charged Paid Credited Due Permit Fee Total 155.00 155.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 80.06 80.06 .00 .00 Grand Total 235.06 235.06 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATIO : �"''" CITY OF ATLANTIC BEACH 1, FILE 800 Seminole Rd Atlantic Beach, FL 32233 copy Ph (904) 247 -5826 Fax (904) 247 -5845. JOB ADDRESS: /8,25 0cea Grove Dr. 14-6 , % L PERMIT # id —Og` PROJECT VALUE $ 1 5 /7 . 00 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's —Elevators/Escalators / Res.�ll a/4 ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name / /c Cl�ll l&S, Ge Phone Number goy -3676- 0099 -Ztv � �end get/ y 4 " 756 Mechanical Company Sa4S l�r�� cc Office Phonez2z- X063 Fax,332 - <116S Co. Address: 5727 1W 7 4 Si. ,#.2g7 7 pp City I - firm/ State FL Zip 33/ License Holder (Print): 'ki:s4t e - L. �iy', ' _ _ State Certification/Registration #2 633 Notarized Signature of License Holder ; -�� / , �j –/72 – _ -�� _ Sworn and subscribed befo r r " _ ... '':•::: • n� I��liE9 "�/ _ 20 2_, 'ae` �`. Notary P ubli c - State of Florida L Signa of Notary Publi ;1 . I. ., , a / FILE OOPS �7� �'�m misaio E 283 r � ..__, ______-----....,7; FLORIDA ELEVATOR SALES & SERVICE 5727 NW 7" St., #287, Miami FL 33126 tel 786.222.8063 fax 786.332.4165 www.floridaelevator.orq February 2, 2012 Probuilders of Florida Job Name Rosero McClain Residence 2 1 1 155 Oak Ridge Dr. South Job ID 8342 Jacksonville , FL 32225 Manufacturer Model Thyssen Krupp Destiny Mr. Luis Rosero Dear Mr. Rosero , Thank you for considering Florida Elevator for your residential elevator project. Enclosed are your Quote and Contract Agreement. Florida Elevator provides factory trained technicians with years of experience installing residential elevator products. As a single source solution provider, we will install, service and carry the warranty. Florida Elevator agrees to furnish all labor, material, services and equipment necessary to install the equipment listed in this quote as per the plans and specifications listed for the amount shown on the Quote attached. Yours truly, Len Abraham Florida Elevator Cell: 407 -963 -5500 Office 407 - 574 -7695 REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH My SEE PERMITS FOR ADDITIONAL 0 REQUIREMENTS AND CONDITIONS. t. REVIEWED BY: I DATA: /,5'7 Z- ir FLORIDA ELEVATOR SALES & SERVICE . , 5727 NW 7tb St., #287, Miami FL 33126 tel 786.222.8063 fax 786.332.4165 www.floridaelevator.orq QUOTE Thyssen Krupp Destiny $19,517.00 Contractor Information TYPE COMMUNICATION DATA Company : Probuilders of Florida Address : 1 1 155 Oak Ridge Dr. South Home 9043860094 C /S /Z : Jacksonville , FL 32225 Email luiserosero @hotmail.com Name : Mr. Luis Rosero Job Site Information Job Name : Rosero McClain Residence 2 Quote Date : February 2, 2012 Address : 1825 Ocean Grove Drive Quote ID : 8342 C /S /Z : Atlantic Beach , FL 32233 Sales Rep.: Leonard Abraham SPECIFICATIONS ITEM DESCRIPTION AMOUNT Manufacturer Model Thyssen Krupp Destiny Stops: 3 Travel 228' Cab Style: Flat Panel Cab Finish: Unfinished Wall Panels : Birch, Oak or Maple Wood Veneer Cab Size: 40" X 54" Cab Height: 78" Ceiling Finish : White (Standard) Ceiling Style : No Framing Ceiling Lights : Two Lights Handrail : Wooden To Match Cab Telephone Box : Brushed Stainless Operator Panel : Brushed Stainless (Standard) Hall Stations : Brushed Stainless (Standard) Gate Detail : Standard Accordion Gate Gate Pocket : Included Gate Opener : Not Included Speed : 40 FPM Capacity : 950 lbs. Warranty : A Three Year Parts and One Year Labor Other : QUOTE TOTAL : $19,517.00 NOTE A: Measured Plans and Drawings Provided NOTE B: THIS QUOTE IS VALID FOR 30 DAYS. Acceptance of this bid requires a deposit. Allow 3 weeks for plans after approval, allow 8 weeks for delivery. NOTE C: ITEMS TO BE DONE BY OTHERS: 1. Hoistway must be plumb, square and meet plan specifications. 2. Electrical disconnects must be provided as shown on plans. 3. Location of electrical components as shown on plans. 4. Telephone jack as shown on plans. ,►_ FLORIDA ELEVATOR SALES & SERVICE 5727 NW 7'r St., #287, Miami FL 33126 tel 786.222.8063 fax 786.332.4165 www.fioridaelevator.orq AGREEMENT Thyssen Krupp Destiny $19,517.00 Contractor Information TYPE COMMUNICATION DATA Company : Probuilders of Florida Home 9043860094 Address : 1 1 155 Oak Ridge Dr. South Email luiserosero @hotmail.com C /S /Z : Jacksonville , FL 32225 Name : Mr. Luis Rosero Job Site Information Job Name : Rosero McClain Residence 2 Quote Date : February 2, 2012 Address : 1825 Ocean Quote ID : 8342 C /S /Z : Atlantic Beach , FL 32233 Sales Rep.: Leonard Abraham This Agreement is entered into this day, the of , 2011 by and between Florida Elevator and Probuilders of Florida hereafter referred to as the Builder. Florida Elevator agrees to furnish all Labor, Material, Services and Equipment necessary to install the equipment listed in this quote as per the plans and specifications listed for the amount shown on the Quote (attached hereto). TERMS Total Price of this Contract is $19,517.00 A deposit of 10% ( $1,951.70 ) is required to provide Engineering & Drawings and to hold the price quoted for a period of six (6) months, or until the end of the calandar year, whichever is sooner.. An additional draw of 60% ( $1 1,710.20 ) will be required prior to ordering the equipment. The balance of the Contract 30% ( $5,855.10 ) shall become due upon the satisfactory completion of the install. If any or all options are selected for this unit, the total contract price will be adjusted to reflect the changes. The progress payments due at each stage of production will change in amount not percentage. Attached to this quote is Addendum "A" which outlines the details of the services Florida Elevator will or will not provide under this quote. Note : A Three Year Parts and One Year Labor Limited Warranty is Included. For Florida Elevator Date For Probuilders of Florida Date a FLORIDA ELEVATOR SALES & SERVICE 5727 NW 7 St., #287, Miami FL 33126 tel 786.222.8063 fax 786.332.4165 www.floridaelevator.orq ADDENDUM 'A' Page 1 of 2 v 09/09 1. Each elevator or dumbwaiter shall be considered a separate job for all purposes and will have a separate S. O. #, job name and warranty. Time is of the essence; therefore Florida Elevator (FE) will coordinate with the Builder when to order and schedule the installation of the equipment. 2. All Change Orders shall be in writing and signed by both parties prior to start of said work. The Contractor shall provide supervision, qualified to process Change Orders during the installation. Florida Elevator reserves the right to charge for delays caused by the contractor or his sub contractors. 3. FE will assist the Builder through the construction stage and will supply a complete set of plans to aid in the construction of the shaft. The Builder shall provide the elevator shaft way free of any debris and in conformance with the manufacturer's plans. FE will inspect, upon request from the Builder, the shaft way at the conclusion of the construction stage to ensure the shaft way is constructed properly. An elevator installation requires normal access to every floor with no impedance from other contractors' work. 4. The Builder is responsible to meet the requirements of the elevator shaft and electrical required per the manufacturer's plans provided and the local code authority having jurisdiction. Variations must be approved in writing. 5. Florida Elevator shall furnish all labor, materials, equipment and certified supervision necessary to construct or perform the elevator installation according to the manufacturer's plans. 6. On commercial contracts requiring Florida Bureau of Elevator Safety state permits and inspections, FE will procure the necessary installation permit and arrange for a Certified Inspector to complete the Certificate of Operation inspection. In the event that the elevator does not pass the initial inspection due to improper or incomplete work provided by others (electrical or other Builder provided subcontracted work) an additional charge of $200.00 will be assessed to cover the re- inspection and additional labor charges associated with that re- inspection. 7. Florida Elevator shall control the manner and method of completing its work and directing its employees, and shall at all times, be considered an independent contractor and not an employee or agent of the General Contractor. 8. Florida Elevator shall be responsible for and pay any and all taxes, contributions, fees and similar expenses imposed directly or indirectly for its work, labor materials and services required by or relating to this agreement. FE shall comply with all Federal, State & Local tax laws, social security acts, unemployment compensation acts and worker's compensation acts insofar as applicable to the performance of this contract. 9. Florida Elevator shall maintain Worker's Compensation Insurance and Comprehensive General Liability Insurance through out the term of this agreement and will provide a certificate naming the Builder as additional insured's. Failure to maintain this insurance shall be deemed a material breach allowing the Builder to terminate this contract. Both parties retain all right allowed under the State Laws that are applicable. 10. Florida Elevator may not subcontract or assign this contract without the written consent of the Builder. 1 1. Florida Elevator will take all the necessary precautions to protect the Owner's property and the finished work of all other trades, and will be responsible for correcting any damage incurred through its negligence. FLORIDA ELEVATOR SALES & SERVICE 5727 NW 7'r St., #287, Miami FL 33126 tel 786.222.8063 fax 786332.4165 www.floridaelevator.orq ADDENDUM 'A' Page 2 of 2 v 09/09 12. Florida Elevator will be responsible to clean the work area at the end of the shift each day and deposit trash in the Builder- provided dumpster. Large items shall be returned to FE unless Builder requests them to remain. Hazardous waste shall be returned for proper disposal. 13. Within the first 90 days of the owner taking possession of the elevator, Florida Elevator will provide the owner with a walk through demonstration of their particular elevator. The demonstration will include but is not limited to the advantages of their particular model, proper working use, safety features and service requirements. Any fine adjustments may be made at this time at no cost to the owner. 14.A payment of 10% is required for each unit to provide manufacturer's drawings, assist the builder, and guarantee the price set forth on the attached estimate for a period of six /6) months or the end of the the calendar year, which ever comes first, unless otherwise agreed. 15.A payment of 60% of the total contract cost of each unit is required prior to placing an order into production unless otherwise agreed. Upon the receipt of the 60% payment, Florida Elevator assumes all liability of equipment purchased from suppliers and shall hold harmless any material liens from said suppliers. 16. Upon installation of each elevator, the remaining balance of the contract, including any change orders, is due in full, provided Florida Elevator can demonstrate to the Builder or his agent that the elevator is in proper working order. Items to be provided by others, but not completed (to include, but not exclusively, doors, trim, phone lines or permanent power) shall not hold up payments to FE. The elevator may not be used until payment has been received. 17. Florida Elevator will endeavor to accommodate the Builder with their internal invoices other than the standard DE invoices. If FE is unable to comply, it will be deemed the responsibility of the Builder to complete their internal invoices. 18. Payment to Florida Elevator is not to constitute or imply acceptance of any portion of its work. 19. Florida Elevator reserves the right to charge the maximum allowable interest on all balance due amounts over 30 days including retainage if applicable. Unpaid invoices over 30 days may constitute a material breach of this contract and suspend all work including warranty items and labor. Arbitration decisions shall not be binding on either party and may not be used in any court of law. 20. In the event of contrary discrepancies, this document shall be primary. National Wheel- O -Vator A Division of ThyssenKrupp Access Destiny DW Series Winding Drum Mode( Main Electrical Supply * Model Number: DW20 208/230 VAC Single Phase (30 Amp Dedicated) Rated Capacity: 950# Cab Lighting Electrical Supply * Car Weight (inc. Frame): 800# 120 VAC Single Phase (15 Amp Dedicated) Pit Depth: 6" Floor To Floor Travel: 228" Controls Overhead: 98" Operation: Automatic Travel Speed: 40 fpm Stops: 3 Cab Final Limits: Upper and Lower Finals LEVEL 3 - Flush Wall Cab Battery Lowering: Floor Selective Clear Platform: 36" x 48" Floor Connections: In The Main Controller Height: 6' 2" 15 Feet Extra Travel Cable Panels: Birch Hoistway Ceiling: Matching Veneer Doors & Hardware: By Others Finish: Unfinished Door Locks: (3) LH DMI Interlock Car Operating Panel: Brushed Stainless Hall Stations: (3) Brushed Stainless Keyed Car Operating Panel: No Keyed Hall Stations: No Cab Lighting: (2) Recessed Down Lights Handrail: Wood Power Door Operator(s): None Flooring: Sill Set For 3/8" Flooring By Others Recessed Phone Box: Std. Mounting - Hinge Right Standard Features Gate UL Listed Controller & Motor Type: Accordion Vinyl Hinged Gate Emergency Stop & Alarm Finish: LIGHT OAK Emergency Cab Lighting No Vision Panels Automatic Cab Lighting Height: 6' 2" Cartop & Pit Stop Switch - "Push To Stop" Autogate Operator: No Machine Stop Switch - "Push To Stop" Floor To Floor Run Timer Drive System Positively Opened Car Gate Switch Machine Room: RMD - IN THE SHAFT Broken Rope Safety Switch LAYDOWN MOTOR Type "A" Instantaneous Safeties (Roller) Single Phase Input - Three Phase Output Inverter 3/8" Wedge Rope Shackles Drive: Hyponic Right Angle Gearmotor 100:1 Field Programmable Alpha Numeric Dot Matrix 3 HP Motor - 1750 RPM Position Indicator In Car 208/230 Three Phase - 8.5 FL Amps Field Programmable Homing Timer Integral Brake Motor 11- 13 ft. Ib. Manual Brake Release Optional Features Manual Lowering Hand Wheel General Duty Main Line Disconnect Drum: 8" Diameter - 12" Length Cab Lighting Disconnect Suspension Means: (2) 3/8" 7x19 Steel Core Aircraft CUSTOM HEIGHT GATE Cables, 14400# Breaking Strength Operating Temperature: 33 - 100° F Buffer Springs: N/A Stop Blocks: N/A National Wheel- O -Vator Amos*, U(,1 y55enKrup Aoctss 569 W. fROU T ST. ROANOKE N1Ag1S 61561 600 - 551 -90J5 WINDING DRUM SPECIFICATION SHEET DESTINY RESIDENTIAL_ ELEVATOR SCAM I DATE: CO BY: DRAWING tEJ:.9ER: NONE 2/28/12 SAR 026551.hrd 1XA1. RAKE: FLORIDA ELEVATOR SALES & SERVICE, FL-4 (* = Items Not Supplied By Manufacturer) JOBREFERF1Kfl PROBUILDERS MCCLAIN RESIDENCE 54 FINISHED HOISTWAY 27 1/4 it OF RAIL — SEE NOTE 4 2 1/4 —•.- t 1 —.. ..-1 1/ 4 r ----, I 12 1/2 1 12 1/2 0 1 „ i 1 j% f ;) t ..ci _ * a ! HANDRAIL SfDE✓ 1 I v) 1 ' I ° I c7i L i o I I ”' o o ON r I 1 N wee m w z 1 1 -- N 0 t 0 O V) z �M I I �o Csi C-4 td v H --- 48 INSIDE - 1 ' ' -. 50 1/2 OUTSIDE .... i j ied C,O,P HC 1 f HALL STATIONS N. TYPICAL ALL FLOORS TYPICAL DOOR LOCATION DETAIL ** HORIZONTAL RUNNING CLEARANCES AS REQUIRED BY ASME A17.1, SECTION 5.3 1 1/4 TYPICAL —.- v s NOTES: . 1) DIMENSIONS ARE FOR LEVEL 1,2, OR 3 ACCORDION GATE 1 11 CAB. ' 2) SHOW LOCATIONS OF COP, HANDRAIL Sc 1/2 (CAR SILL TO GATE) -.1 ACCESSORIES IF DIFFERENT THAN SHOWN. 5 MAX** (INSIDE FACE OF 1 1 3) *— DIMENSION IS FOR CENTERLINE OF HOISTWAY DOOR TO STANDARD 36" DOOR. FOR OTHER SIZE, OUTSIDE OF GATE) i i CONSULT FACTORY. 3 MAX** —« I (4)2x10'S, 25" O.C. REF. EL- 2003B. FOR 4) TYPICAL WOOD FRAME BACKING WITH (INSIDE FACE OF HOISTWAY DOOR TO SILL) 1 i 1 , ANY OTHER APPLICATION CONSULT DEALER. 1/2 -1 1/4 ** RUN CLR _ ( 5) ALL DIMENSIONS IN INCHES. (SILL TO SILL) 6) COP =CAR OPERATING PANEL, PB= OPTIONAL RECESSED PHONE BOX, HC =HALL DOOR LOCK CALL (TYP ALL FLOORS) 6 ______ RT RAIL — 1 OPEN — LH DOOR ^ThyssenKruftE 11NOIS6156 . 1- 800 -55t -9095 Access FAX 1- 800 -551 -9095 DESTINY RESIDENTIAL ELEVATOR awc Ere: SAR SCALE: NONE 1 2/27/12 EN/C I: 26551 ,as: PROBUILDERS MCCLAIN RESIDENCE DEALER: FLORIDA ELEVATOR SALES & SERVICE NOTES: 1) 8'0" OVERHEAD REQUIRED FOR 7` -2" CAB HEIGHT. (INCLUDES 9" OF CARTOP CLEARANCE.) D r - 11 . WINDING DRUMS WITH THE MACHINES IN THE SHAFT: --- -- (RMD DRIVE) REQUIRES 15" ADDITIONAL OVERHEAD. j \ CAB HEIGHT OVER 7' -2" REQUIRES ADDITIONAL OVERHEAD. 1- / 1-3/ 0 IF THE MINIMUM OVERHEAD REQUIREMENT CANNOT BE 4 / Z z OBTAINED OR FOR CUSTOM CAB HEIGHT CONTACT THE a w \\ / w NATIONAL WHEE -O -VATOR CO., INC. z \\ / o Q 2) MINIMUM FLOOR TO FLOOR TRAVEL IS 16" BETWEEN '" x FLOORS / \ o z (IF TRAVEL IS LESS THAN 16" CONSULT FACTORY) _ - / \ z MAXIMUM FLOOR TO FLOOR TRAVEL: iv 00 / oc -J Ib O 750LB UNIT= 50'0" kb > \ Co 950L8 UNIT= 44'0" (DH MODEL) 0 I = 50'0" (DW MODEL) / \ / ^� \\ 3) CONSULT FACTORY FOR MINIMUM PIT DEPTH. 1 i / I 1 IMPACT LOAD @ PIT + ... -I J_ 4300 LBS (750# CAPACITY) + 4700 LBS (950# CAPACITY) STATIC LOAD @ PIT 2700 LBS (750# CAPACITY) 2900 LBS (950# CAPACITY) == _ _r- BUFFER SPRINGS REQUIRE 9" PIT DEPTH MINIMUM. / v 4) CONSULT LOCAL AUTHORITY TO ENSURE COMPLIANCE \ I V- g WITH STATE AND LOCAL CODES. tp \ / z z \ / zf"u t 5) THE HOISTWAY IS REQUIRED TO BE FREE OF ALL PIPES, o \\ / $ v� 0 WIRING, AND OBSTRUCTIONS NOT RELATED TO THE a \ \// a >-- + OPERATION OF THE ELEVATOR. /\ 6) RMD DRIVE ONLY. p / \ o so MACHINE APPROXIMATE WEIGHT = 330 LBS. z / \ 1 J � co / \ co -¢' co / \ io Z W a / i w 0 \ N d + - JOR SPFCIFIC INFORMATION: r o 1 332 IOVERALL HOISTWAY H 0 98 OVERHEAD = Z J' I - / 228 FLOOR TO FLOOR TRAVEL 4 \ / z 6 PIT DEPTH 6 \ / 1 0 \ / o >- \ / >- a \/ z Q /\ v / \ W O / \ O p 00 / \\ co w a.� Th yssenKruP� i 0 s eiss, / \ �w Access soo -5s, -9095 3 -STOP ELEVATION sv / I I — - DESTINY RESIDENTIAL ELEVATOR scuE: DAT uri : DR,W.I �c ►iu a : ' _ - - I + NONE l 2128/ 12 SAR aw 26551 DEALER: FLORIDA ELEVATOR SALES & SERVICE I JOB: PROBUILDERS MCCLAIN RESIDENCE C r_ OF RAILS RAIL SEE NOTE (2) WAIL ---12 1/2" -•- ----12 1/2" -�- SEE NOTE (1) ___�_ 1, ,_ ____ v_ I I I I I I 021 I I I I VA I I I P A I • • I /411 I I I I rA I I I I►�.� 'A M' I I I I MI ,∎•■ -- ,.... � o A - _ _ _ —_ —_ o _ - ROCK 1 1 ' 4" d , s 28" D.B.G. PEDESTAL 34" BASE d 1` -SEE NOTE (3) CONTRACTOR'S RESPONSIBILITY: 6.25# R PR OVIDE ADEQUATE WALL I 11 SUPPORTS FOR T -RAIL FLOORING TEE RAIL R2 FASTENINGS. VERTICAL FLOOR INTERVALS NOT TO EXCEED JOISTS RAIL REACTIONS 10'0" (SECTION A -A). BY CAPACITY COMPLY TO ALL PERTINENT < t BUILDING CODES FOR (PER RAIL) HOISTWAY CONSTRUCTION 750# 950 AND FIRE RATING. HOISTWAY ,�� TO BE VERTICAL WITHIN )\ R1 = 150 R1 = 175 1/8" THROUGHOUT ENTIRE / R2 = 400 R2 = 450 HEIGHT. . \ X RAIL BRACKET FRONT o L 25" 1-< k SECTION A —A - 32" 34" NOTES: (1) TWO 2X10's LAMINATED WITH GLUE, SUPPORTED AND FASTENED BETWEEN 2 -2X4's RECESSED IN HOISTWAY WALL BEHIND THE SHEETROCK. n Thvs s en K ru I ���� a°9 w. FRONT SL 1 RVM(OKE, ILUNOIS 61581 ccess 800- 551 -9095 (2) RAIL CENTERLINE CAN BE LOCATED ON THE HOISTWAY OVERVIEW T -RAIL BACKING REQUIREMENTS DRAWING. DESTINY RESIDENTIAL ELEVATOR SCALE: DATE DRAWN BY: DRAWING NUMBER: (3) PEDESTAL CUP D /A BE NONE , 2/27/12 SAR 26551 MODELS. SUGGESTED AN BACKOR ING DE SHOWN D END ABOVE HITCH TO MAY AN CH N OR ELEVATOR RAIL DEALER: BRACKETS. FLORIDA ELEVATOR SALES & SERVICE JOB: PROBUILDERS MCCLAIN RESIDENCE , MIN 20 1/2" FOR 33' OF TRAVEL OR LESS RAIL WALL •' 4 L:V_L L — 1 MAX TRAVEL 8' 10' 12' 14' 16' 18' 20' 22' 24' 25' 27' 29' 31' 33' c0 w IlI STARTING WRAPS 4 3 2 1 5 4 3 2 1 5 4 3 2 1 DRUM LEN r r i 1101111140111 AWC TRAVEL (IN FEET) 8• 35' 37' 39' 41' 43' 44' 46' 48' 50' N STARTING WRAPS 5 4 3 2 1 4 3 2 1 I { j RAIL I C/L DRUM LENGTH 20' 23' ISE LF LOCKING, SELF CLOSING .. —.. —.J ACCESS DOOR L 24 — (BY OTHERS) NOTES: 1) 3' --•O" DEEP X 2' -6" WIDE MINIMUM 171 m CLEARANCE IN FRONT OF THE CONTROL REMOVAStSwERCOM FOR IF A PANEL REQUIRED BY N.E.C. ii...7„.s. — — — — 2) DISCONNECT SWITCHES AND LIGHT SWITCH TO BE LOCATED ON THE STRIKE 24 12 j SIDE OF THE MACHINE ROOM DOOR. I , 3) MAIN LINE DISCONNECT TO BE FUSED ! AND CAPABLE OF BEING LOCKED IN THE 11 OPEN POSITION. • 4) CAB LIGHT DISCONNECT TO BE *ALTERNATE ACC CAPABLE OF BEING LOCKED IN THE OPEN LOCATION POSITION AND HAVING OVERCURRENT (BY OTHERS) PROTECTION MEANS IN THE MACHINE *ADDITIONAL OVERHEAD ROOM. MAY BE REQUIRED FOR INSTALLTION 5) MAIN CONTROL PANEL MUST NOT BE OVER 40' AWAY FROM THE DRIVE MACHINE. 6) MANUAL LOWERING INSTRUCTIONS BATTERY MUST BE POSTED WITHIN SIGHT OF LOWERING THE MACHINE. TYPICALLY ON THE INSIDE 16 "WX16 "1-I OF THE ACCESS DOOR. X 6 "D MIN LINE CO MAIN LINE DISCONNECT DISC. Ct 3 POLE MAIN (1 POLE FOR BATTERY DISCONNECT) CONTROL as PANEL `� DISC. SC. ** CAB LIGHTING DISCONNECT BY OTHERS ** 24'1N X CAB LIGHTING DISCONNECT 24 "H X 8 "D f 1 POLE INVER Drawl * *DEALER IS RESPONSIBLE FOR 42 MINIMUM INSURING THAT THE MACHINE SPACE LAYOUT AND THE MACHINE LOCATION , 36 MEET CODE REQUIREMENTS IMPOSED BY LOCAL AUTHORITY HAVING \\ 00 JURISDICTION ** D ; TELEPHONE co CONNECTION Z (BY OTHERS) 7h ssenKrup 5os W. FRONT sT. KE ILLINOIS 61561 L__ -� DUPLEX e Access 600- 651 -9095 �� -- ___ -_ - - - RECEPTACLE & RMD -SHAFT LAYDOWN MACHINE LAYOUT LIGHT SWITCH DESTINY RESIDENTIAL ELEVATOR j (BY OTHERS) SCALE: ONE 2/ 27/12 DRAWN AR 1 2655 1 NUMBER: DEALER: 3 MIN. CLEAR SELF LOCKI G FLORIDA ELEVATOR SALES & SERVICES A CESS IOOR BY a TH R JOB: PROBUILDERS MCCLAIN RESIDENCE . . Destiny Aflr 11..................................................................._ ......,____.....„.............,......._. .... , . . , ... _.............. ...... . . .. .,. ....., .., ... 7.,. ,,, .,.. ,,t4,....._. • i", '4 A BIC. i,,, ,_,..., ,, .., ,,,, . - • N TYPES . - ..,.. ,..,-. - j* •',.' ' ,,,,,,,,, , J.: • ' - .''' ' . . .:'".ft":" ' .,, ... '-'--`"I''''''1744"4.'''-' . • „ , • . .„- ... ,„,. - ,-,,,,..--• - ,kik , ,,,,,,...„,_ , „ . 1 f .- 0: . , ,, , ..-,, , ,, --,„ ' ..' , , : I . ; .;",-;. ' .;,-. ..--- • -_,-. f . , - ' '--"--,:, -- 1.V.Z . '•' - ' - ' , '• , , , - . A- --:',„•.'",f,-, *.--';?-fiti";;;;-/k-:.--.--''', - - " „•• • . • . , . .: . ,...... 'I:I r ';•• -•• - - - ,,:.; • ' , k ,, ‘ N 3 -' '-_,-,,-,,,:-:,:',,. ':' ' . . i . • „. ... ,.. . ..... .....„,.. ....,. ...,. ...., .. . .... . .... . .. . ..,........: . ..„... " 6 ii, ; ,,,,'-',--:, li". 11", .,, ? - ..- ; ! ' ' ' ,,,,,,,•,•,-,"'„,./' , ' - ,,,-..,,, .';': '-, , .: - , • ......... t- „,,%,:, .•:..i.,,,...t - • i ,:;.., , . k ...„..--„ , • , - . •.,- - ..4” ': t : . ' ''''''.' t iti kk -.. ''' - .‘,...;• . - 4,.;,... - : ,:eig! , ' oi , ,. - .,,,, " • ks , , , , ---,-;:.,•-• .. - - :z ' - -1 14-'" ,- -- 11 ---,' -- <• -,,,,,, ,k. • "i';','- - " .:',.P';'_iv:::"" 1 ," J , t. 'kJ' , ' - - . : , •,.....A..., ' , .„. k_ - . .._ •••,.• : • - . , ki , , ,, , ,,,,, - --: kf.,F ,,,. k , ,, . ti : - . ,. ' ' , , . • . , ......„ - , .. - ... - ,, ' ,.. ',-,','• - - ,' . „.„,, . ' ' ', ..• ,,,i= • ,i,',.',„-- Air --- - , „ ,.. , ,.• , .,„ 8A sE tu -1 - ....,., ..........___ •-________________., ....„..........._,.....____ ASME A17.1 _• Section 5.3 08.24.2011 4i5,\ ThyssenKrupp - ::-:„..-,-,,,,,,,,,,:,,,,,,.17,--,i,mgi•-..--- - Thyssen Krupp Access Table of Contents Page # Equipment 3 Typical Hoistway Layouts 4,5 Recommended Hoistway Construction 6,7 Hydraulic Drive Machine Room Layout 8 RMR (Reduced Machine Room) Layout 9 RMD (Rail Mount Drum) Layout 10 Typical Electrical Space Layout For RMD 11 Compact Machine Room Layout For RMR 11 Specifications 12 -15 Introduction: Our Design Guide was created to assist the architect and builder by providing a guide to incorporate a Destiny residential elevator into a new or existing home. When planning for your Destiny residential elevator, the following questions need to be answered: • Do you meet local, state and national code requirements? • What are your hoistway and car size requirements? • Have you planned for a machine room and the electrical requirements? 7hyssenKrupp Access Manufacturing, LLC is dedicated to providing our partners unequaled value by offering products of the highest quality, complemented by unrivaled customer service. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 2 of 16 REVD 08.24.11 DM -204 Equipment General: • Pit switch • Travel: Up to 50' • Manual lowering device • Load capacity: • Pre -wired car Roped Hydraulic Drive — 950 Ibs up to 44' • Two stops (750 lbs up to 50') • Auto- homing Winding Drum Drive — 950 lbs or 750 lbs • Single opening • Speed: 40 fpm (optional 30 or 36 fpm) • Three year limited parts warranty • Overhead: 96" minimum: RMD 109" min. (for Overhead Clearance Options, see page 6) Optional Features: • Pit depth: 6" minimum (8" recommended) • Custom car size • 7'4" & 7'10" car heights Choice of Drive Systems: • No.8 (polished) brass, No.8 (polished) • Roped Hydraulic Drive stainless steel, or No.4 oil rubbed brass hall call, 1. 1:2 roped hydraulic. car operation panel and phone box 2. Remote machine room can be located up to • Melamine, laminate or custom wood veneer 40' from the unit. interiors 3. 3HP submerged motor with 2 -speed valve • Wood veneer or clear panel accordion gate assembly. • Raised or recessed panel car — birch, red oak, • Winding Drum Drive cherry, maple or hickory 1. 3HP Inverter controlled winding drum unit. • Single or deluxe frame ceiling in matching 2. RMD (Rail Mount Drum), RMR (Reduced hardwood Machine Room), plus other varieties of • Auto gate operator (accordion gate only) with drum layout configurations. battery backup • Finished flooring — light oak or dark oak Standard Features: • Three to six stops • Car size: Up to 15 sq.ft. • Handrail • 7' interior ceiling height 1. No.4 (brushed) brass • No.4 (brushed) stainless steel or No.4 (brushed) 2. No.8 (polished) brass brass hall call and car operating panel 3. No.4 (brushed) stainless steel • Wood handrail 4. No.8 (polished) stainless steel • Birch, oak, or maple veneer interior walls 5. No.4 oil rubbed brass • Accordion gate • Two recessed halogen lights • White melamine, oak veneer, birch veneer, or maple veneer ceiling • Unfinished plywood floor • Sill set for 3/4" finished floor • Telephone jack — surface mount • Digital floor position indicator • "Car Here" and call acknowledgement lights • Automatic on /off car lighting • Emergency stop switch and alarm button • Emergency lighting • Self Diagnostic System ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 3 of 16 REV D 08.24.11 DM -204 Typical Hoistway Layouts Depth Depth Center of Center of Rail 1 7 Rail I ii i _ Center r - Center of Door of Door L_ i i Layout 1 i i Width Width Layout 1 - I Left Hand Right Hand — I - 1 — II II Left Hand Rail /Right Hand Door Right Hand Rail /Left Hand Door Car Size Width Depth Center of Center of Rail Door 36" x 48" 54" 54 1 /2" 27 1/4" 28 3/4" 36" x 48" 51 1/2" 54" 27 1/4" 28 3/4" Compact Hoistway 42" x 48" 59" 54 1/2" 27 1/4" 34 3/4" 36" x 60" 54" 66 1/2" 33 1/4" 28 3/4" 40" x 54" 57" 60 1/2" 30 1/4" 32 3/4" Depth Depth r , \ (I Layout 2 Width Width Layout 2 Left Hand Right Hand t i-- . 711 1 I Center of Center of l l Door 1 Door 1 - - - -- - - - -- — — Center of — l L. Center of Door 2 Door 2 90 Deg. Car Left Hand Door /Right Hand Door 90 Deg. Car Right Hand Door /Left Hand Door Car Size Width Depth Center of Center of Center of Rail Door 1 Door 2 40" x 48" 54 3/4" 57 1/2" 27 1/4" 25 1/2" 28" 42" x 48" 56 3/4" 57 1/2" 27 114" 25 1/2" 28" 40" x 54" 54 3/4" 63 1/2" 30 1/4" 25 1/2" 34" ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816 - 763 -4467 • Page 4 of 15 REVD 08.24.11 DM -204 Typical Hoistway Layouts .. Width _ Width Center i .. Center of Rail `' s Layout 3 L ayout 3 ' ` " Depth Depth # ' Left Hand Right Hand i p i H ___ _ t Center — " Center of Door Car Size Width Depth Center of Center of of Door Rail Door 36" x 48" 47 1/2" 62 1/2" 23 3/4" 22 1/4" 42" x 48" 51 1/2" 62 1/2" 25 3/4" 22 1/4" 36" x 60" 47 1/2" 74 1/2" 23 3/4" 22 1/4" 40" x 54" 50 1/2" 68 1/2" 25 1/4" 22 1/4" Depth • Center of Rail i a I 11��11� ;- Car Size Width Depth Center of Cen ofl �� . . Center p I 1 Rail Door of Door 36" x 48" 54" 54 1/2" 27 1/4" 28 3/4" 28 3/4" ' I Layout 4 36" x 48" 51 1/2" 54" 27 1/4" Width L . E J Compact Hoistway 42" x 48" 59" 54 1/2" 27 1/4" 34 3/4" 36" x 60" 54" 66 1/2" 33 1/4" 28 3/4" _ 40" x 54" 57" 60 1/2" 30 1/4" 32 3/4" pi . �r Opposite Opening Car Right Hand Door /Left Hand Door Dimensions are from the inside finished hoistway and calculated using 1 1/4" car wall thickness. Please contact your local dealer for more information on our custom car sizes. We recommend the handing of the car gates to be the same as the hoistway door. The car doors can be either hand, but this handing must be consistent on every level. Changing the door swing may affect hoistway dimensions. Contact your local representative or ThyssenKrupp Access Manufacturing, LLC for more details on our car sizes. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800- 829 -9760 • Fax: 816- 763 -4467 • Page 6 of 16 R 08 D M -20EV D 4 Recommended Hoistway Construction (2) 2x10 laminated, supported and *Stud at center line of rail aids bracket fastened between (2) 2x4 behind alignment gypsum board for supporting rail brackets Q_ Dimensions required by bra rail ASME A17.1 --12 1 /2"r --- The maximum distance between —i12 1/2 °i— the hoistway door and the At �i� ►i� of ►U 1,1 ►.� ; hoistway sill is 3 ". A i — The maximum distance between the inside face of the hoistway „ ,......... , I door and the car gate is 5 ". s" MAX---i The clearance from sill to sill Typical stud and wall f should be 1/2” - 1 1/2 ". 3" MAX — board construction 1/2" -1 1/2" --- L-- wol " " " ' Overhead Clearance Options CAB RMR RMD RMD HYDRO (in the shaft) (in the attic) These numbers are based on our 6'8" 96" 105" 90" 90" standard cab traveling 40' per minute. Add 1" for Level VI cab. 7'2" 96" 111" 96" 96" 7'11" 105" 120" 105" 105" m n rti , r . i / 9 Q Impact Load @ Pit , \ 4300 Ibs (750# Capacity) ;;;L__ / I —• j \ j v 4650 Ibs (950# Capacity) I . g Static Load @ Pit ig 2675 Ibs (750# Capacity) g -k 2700 Ibs (950# Capacity) _,,^, — - r 1- \ \ 2 R q \ 8 O \/ Q O 4 • b \\ b? tiJ 1 ,. y i f ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816 - 763 -4467 • Page 6 of 16 REV D 08.24.11 DM -204 Recommended Hoistway Construction •' „,,,� ,,�v Rail Reactions -10/ l 750# 950# R1 = 150 R1 = 175 R2 = 400 R2 = 450 R R2 [ % . • • .. Ft. ..,.., I •_ ' FF',:ggr RAIL BACKING CONSTRUCTION I ►� i x DETAILS: m - LAMINATE (2) 2X10'S & (2) \ , ''s.'"` ' o 2X4'S WITH GLUE AND #8X234." 11\ SCREWS. - RAIL BACKING JOINTS MUST BE , ` -� i STAGGERED. �. 11 11111111 6 • I SECTION A —A RAIL BRACKETS SECURED � � TO THE BACKING WITH I (2) %" X 4" LAG BOLTS. \. \ EACH ANCHOR HAS 450# PULL OUT FORCE. ... SHEETROCK - -- --4- le°°`, DETAIL AT INTERMEDIATE FLOOR `•-•-.. V 4400. NOTES: . (1) TWO (2) 2X10'S & TWO (2) 2X4 "S WITH GLUE AND #8X2 i SCREWS. RECESSED IN HOISTWAY WALL BEHIND THE SHEETROCK. 5/8 INCH 72 SETBACK FOR � - „ 2 (2) RAIL CENTERLINE CAN BE LOCATED ON IIII SHEETROCK THE HOISTWAY OVERVIEW DRAWING. PIT WALL CENTERLINE OF/ 72 CONTRACTOR'S RESPONSIBILITY: / PROVIDE ADEQUATE WALL SUPPORTS FOR T -RAIL PIT FLOOR - ' BACKING -� FASTENINGS. VERTICAL INTERVALS NOT TO EXCEED 10'0” (SECTION A -A). COMPLY TO ALL PERTINENT BUILDING CODES FOR HOISTWAY CONSTRUCTION AND TYPICAL HOISTWAY DETAIL FIRE RATING. HOISTWAY TO BE VERTICAL WITHIN 1/8" THROUGHOUT ENTIRE HEIGHT. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816 - 763 -4467 • Page 7 of 15 REV D 08.24.11 DM -204 Hydraulic Drive Machine Room Layout Standard Machine Room Layout 48 AIN CONTROL BOX 7 1 /2 I-- } Machine room must meet local, state and national codes. TELEPHONE CONNECTION o Main control box measurement: 24 "H x 24 "W x 8 "D MAIN LINE 4 ---.-- O CIIA Power unit measurement: DISCONNECT & n o � © 35 "H x 24 1/4 "W x 12 1 /2 "D 00 CAB LIGHTING LY O O `t DISCONNECTS Work space required in front of the disconnects and main control box: POWER 30 "W x36 "D LIGHT SWITCH & UNIT o DUPLEX-----_______ Other material needed: RECEPTACLE IGHT • Telephone connection — • Main line disconnect • Car lighting disconnect • Light switch and G.F.I. duplex receptacle • Access door 2 -6" MIN. CLEAR • Light SELF CLOSING, • Main control box backing (if required) SELF LOCKING, f ACCESS DOOR Compant Machine Room Layout T I 48 Fj do . . . . 1 MAIN CONTROL TELEPHONE PANEL CONNECTION !------//POWER �— \ —* Pr / 0 % MAIN CONTROL '' % ,t. /' BOX BACKING MAIN LINE cN I , 1 DISCONNECT & CAB LIGHTING DISCONNECTS MAIN r h. ,,,,_ LIGHT SWITCH CONTROL &DUPLEX MI n BOX RECEPTICLE —__ SUBMERGED POWER UNIT 3" MIN. CLEAR SELF 6" LOCKING ACCESS DOOR 61 1 . ' 1 1 _L Overhead View Front View ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816 - 763 -4467 • Page 8 of 15 REVD 08.24.11 DM -204 RMR (Reduced Machine Room) Layout + I N CONTRO BOX I '- �� 24' 24'X8' z . -1- ,IYi _ • 1 i TELEPHONE CONNECTION cam • 4— 1 z 3 RIM Will .E• • 1 1 • 1 •'C T 3 IIII. MACHINE ROOM LIGHTING • 1 • 5 Ty 1/8 MAIN LINE DISCONNECT, CAR LIGHTING DISCONNECT, J f4 'C` = 16 -MIN LIGHT SWITCH, AND DUPLEX RECEPTACLE (N le"011 2' -6" MIN. CLEAR SELF LOSING, SELF LOCKING— it DOOR —13 MIN MACHINE SPACE WIDTH = "C" + 44" 9 ,p Mmv 1111 Machine room must meet local, state and national codes. Main Control Box measurement: - - 24 "H x 24 "W x 8 "D Optional battery lowering box measurement: (- -2'" I 12"- 16 "H x 16 "W x 6 "D DINE Work space required in front of the AMAIN CONTROL disconnects and main control box: PANEL 30 "W x 36 "D I W N 4" minimum concrete slab required • 8 8, ' REMOVPIRE COVER FOR AMA. WRENN; RAROWEEL 4 Other materials needed: g + • • Telephone connection •E , Ktmin — ;"_KZ • Main line disconnect r ` I • Car lighting disconnect 1. t 4 C O NO f IF NOT • Light switch and G.F.I. duplex receptacle V AVAUBLE CONTACT FACTORY. • Access door • Light RMR - Floor Mount RMR Drum Chart Max. Travel (In Feet) 8' 10' 12' 14' 16' 18' 20' 22' 24' 25' 27' 29' 31' 33' 35' 37' 39' 41' 43' 44' 46' 48' 50' Starting Wraps 4 3 7 1 5 4 3 7 1 5 4 3 2 1 5 4 3 2 1 4 3 2 1 Kmin = (K1 +K2) min 56" 56" 56" 56" 56" 56' 56" 56" _ 56" 56" 59" 66" 74" 81" 85"_ 92" 99" 106" 113" 116. 124", 131" 138' Drum Length 8" 12" 16" 20" 23" Drum C/L "D 8 3/4" 10 3/4" 17 3/4" 16 1/4" 16 1/4' Machine Base "E" 24 1/2" 28 1/2" 33 1/8" 39 1/2" 39 1/2" Wall Cutout Width "W" 17" 17" 17' 25' 25" ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800- 829 -9760 • Fax: 816 - 763 -4467 • Page 9 of 15 REV D 08.24.11 DM -204 RMD (Rail Mount Drum) Layout By utilizing our RMD (Rail Mount Drum), you can eliminate the need for a machine room. (Per NEC, National Electrical Code, a separate electrical space may be required.) This winding drum layout provides the perfect solution for those applications where space is a problem. The drawings below show the drive system located in the attic and in the shaft. ThyssenKrupp Access offers a variety of mountings for the winding drum. Please contact us for more information. *RAIL CENTERLINE— MINIMUM DISTANCE 23 3/4" OVER 33' TRAVEL 2C 1/2" UNDER 33' TRAVEL r 6" f 24" RAIL r , -- -- - - ©-- LL, WALL J F CAL N I W i = Z - N Q L_ ..... ,, . = RAIL C L - - SELF LOCKING, i "Ph SELF CLOSING �~ ACCESS DOOR -- \. "--- RAIL WALL < U z • ju REwOVA9LE COVER FOR , .' WL NERiN(: .IIITw .1••• MMIOWNEEL LO ! Pi 1111L ..1/1.41■- I tillina T I T 1)(1 '17 ,( 1 )1 1. N I ..........._. F I - 2 4" MACHINE k --- ES I° ° - ROOM FLOOR a t2 "� i i OR DECKING *ALTERNATE ACCS DOOR LOCATION I ° a 2 X 8's FLOOR k 0 1 JOISTS IF OTHER *ADDITIONAL OVERHEAD PLEASE NOTE. MAY BE REQUIRED FOR INSTALLTION ^ ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 10 of 15 REVD 08.24.11 DM -204 Typical Control Space Layout For RMD 42" MINIMUM 1 BATTERY — LOWERING 36" , 16 "WX16 "H ` v X 6"D I 0 I TELEPHONE LINE 00 n CONNECTION MAIN osc. ' 2 - CONTROL cm L _ . __ DUPLEX BOX LIGHT asc. RECEPTACLE & - - 24"W X — " - - — - LIGHT SWITCH 24"H X 8 "D I ` iNVERTER1_ DRIVE 3' MIN. CLEAR SELF LOCKING — ACCESS DOOR Compact Machine Room Layout for RMR s x a*us r4 i t;R Y s., BA- TERM:' r z LOWERING >- cc w 16 "W x 16 "H x 6'D Z Q ?s (optional) co 0 Main i ' control box backing NVERTER I DRIVE O i MAIN I CONTROL Z o BOX ,a U m DISC. 24'W x 24 "H x 8 "D ti Z CAR ms s: > LIGHT DISC. Note: When battery backup is utilized, a � a RMR if ceiling of 8'0" and sHEAVE door size of 3'0" x g WINDOW 8'0" is preferred. __I S n ThyssenKrupp Access's Destiny residential elevator will add value and convenience to every level of your home. From the "' elegant wood interior walls to the stylish lighting, this elevator car will compliment any decor. Your elevator car can be handcrafted in a variety of designs and wood finishes. Our assortment of accordion gates provide safety and enhance your D estiny's beauty. A choice of stainless steel or brass fixtures will add the finishing touch to your Destiny residential elevator. T hyssenKrupp Access is here to assist you in tailoring the Destiny to your own personal taste. egj Please note: Plans and specifications are subject to change. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 11 of 15 REV D 08.24.11 DM -204 Division 14235 Residential Elevator 1:2 Roped Hydraulic Part 1 General C. Shop Drawings: 1.01 SECTION INCLUDES 1. Shop drawings showing all field construction, including A. Residential elevator with 1:2 roped hydraulic lift system. dimensions. 2. Hoistway dimensions. 1.02 WORK INCLUDED 3. Wiring diagrams. A. Furnish all labor and materials, equipment and incidentals 4. Maintenance instructions. necessary to assemble and erect a residential elevator, 5. Car and gate selection charts. complete with a remote power unit and all hoses, rails, brackets, connections and controls essential for proper 1.07 QUALITY ASSURANCE operation. A. Qualifications: Installer Qualifications: A company experienced in the assembly 1.03 WORK BY OTHERS and erection of lifts and residential elevators of the type specified. A. Construct a hoistway of the size required by the Manufacturer Qualifications: A company specializing in the manufacturer, complete with all demolition, additional framing, manufacture of residential elevators. headers and framing components necessary to prepare the B. Regulatory Requirements: The complete manufacture, existing building to receive the elevator. fabrication and erecting of the elevator shall be in compliance 1. Hoistway size: Dependent upon car size. with all Federal, State and local codes and ordinances. The 2. The hoistway shall be vertical to within 1/8" throughout installer shall verify requirements of the local authority having the entire height. jurisdiction and shall comply with all local codes and ordinances. 3. Provide and fasten structural members in hoistway per manufacturer's recommendation. 1.08 DELIVERY, HANDLING & STORAGE 4. Pit requirements: Provide 8" deep pit (minimum 6" A. All components shall be shipped to the site in substantial deep). Install reinforcement and concrete as necessary. crates to protect from damage during shipping and handling. Floor must sustain load specified in job drawings. Upon arrival, inspect components and keep under cover until B. Construct a machine room: installed. 1. Provide elevator electrical circuit: 208/230 volt AC /1 phase /60hz (30 amp). 1.09 WARRANTY 2. Provide elevator lighting electrical circuit: 115 volt A. Unit shall have a three (3) year limited parts warranty. (15 amp). C. Provide system to maintain hoistway and machine room 1.10 MAINTENANCE temperature between 50 -90 degrees Fahrenheit. A. Maintenance of the private residential elevator shall consist of regular cleaning and inspection at intervals not longer than every 1.04 REFERENCES: 12 months. A. General: The applicable provisions of the following B. Inspection: ASME A17.1 requires all private residential standards shall apply as if written here in their entirety. elevators to be inspected every 12 months. B. American Society of Mechanical Engineers /American National Standards Institute (ASME /ANSI) publications: ASME/ PART 2 PRODUCTS ANSI A17.1 "Safety Codes for Elevators and Escalators ", 2.01 MANUFACTURERS Section 5.3. A. Manufacturer: "Destiny" model by ThyssenKrupp Access. C. National Fire Protection Association (NFPA) publications: B. Substitutions: No substitution shall be considered unless NFPA 70 National Electrical Code. written request for approval has been submitted and received by the architect at least ten (10) days prior to the bid date. 1.05 SYSTEM DESCRIPTION: A. Travel: (50' max) 2.02 COMPONENTS B. Stops: (up to 6) A. Car: C. Load capacity: 950 Ib. up to 44' (750 Ib. up to 50') 1. Size: 36 "W x 48 "D (others available). D. Speed: 40 fpm 2. Enclosure: Securely fastened to the car frame and platform. The car shall be constructed of a minimum 3/4" 1.06 SUBMITTALS wood walls. Floorboard shall be constructed of 3/4" AC A. Submittals shall be in accordance with Section 01300, plywood. SUBMITTALS. B. Product Data: Submit product data, including manufacturer's specifications. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 12 of 16 REVD 08.24.11 DM-204 3. Gate: Accordion equipped with a positively opened maintain car within 1/4" of the landing. mechanical switch to indicate that the door is closed. J. Control systems: Non - selective collective PLC. 4. Handrail: One, located on the car wall. K. Motor (submerged): 3.0 HP, 1750 -RPM 208/230 VAC, 5. Telephone: Wall mount telephone jack shipped loose with single phase. elevator. L. Wiring: 6. Control panel: Provide one momentary pressure 1. Provide flexible traveling cable for electrical lights and illuminated button for each landing, emergency stop and controls in car. alarm button, and a digital position indicator; all mounted in 2. All other electrical wiring shall be insulated, flame a control panel having a stainless steel or brass retardant and moisture proof copper wiring, installed in cover. flexible metal conduit. 7. Interior lighting: Provide overhead light fixtures that M. Safety devices: automatically turn on when the car is in operation and turn 1. Slack cable protection: Provide a stainless steel linkage off by means of a timer circuit. device that stops and sustains the car in the event of breakage B. Hoistway door: or slackening of cables. 1. Size: 3'0 "W x 6'8" Fl swing type 2. Terminal stopping device: Shall be provided at the top 2. The general contractor or owner is to furnish (elevator and bottom of the car travel. contractor may opt to furnish) and install hoistway doors, 3. Provide a platform toe guard at the car entrance. frames, hinges and passage sets at each landing. The type N. Battery emergency operation system: and installation of the doors and frames must comply with 1. Powers a light in the car. ASME A17.1, all local codes and manufacturer's 2. Powers an emergency alarm system. layout drawings. 3. Powers a system to allow car to descend to floor selected 3. Locking Device: Door shall have a concealed locking by passenger. device, interlocked with the car operation, to interrupt 4. The batteries shall be a rechargeable type complete with electrical power when the door is not securely closed and a an automatic recharging system. car is not at the landing. The door shall be locked when car 0. "Self Diagnostic System" utilizing diagnostic codes displayed is not in the landing zone. in hall and car acknowledgement lights to provide information in C. Hydraulic power unit: the event the elevator will not operate. 1. The pump, submerged motor and valve shall be prewired, ready for connection to the controller in the field. 2.03 ACCESSORIES 2. Up direction acceleration adjustment. Specifier Note: Due to the individual nature of elevator installations, 3. Two speed operation. accessories such as, but not limited to those in the following list 4. Adjustable pressure relief valves. are available: 5. Manually operated down valve for emergency operation. A. Hoistway doors and door locks. 6. Pressure gauges and pressure gauge isolation valves. B. Flush mounted telephone box. 7. Manual valve isolation between pump unit and jack. C. Car door finish and design. 8. Negative pressure switch provided. D. Car operating panel and hall call finishes. 9. Testing: Shall be factory tested prior to shipment. E. Car trim and wood specie. 10. Muffler provided for quiet operation. F. Custom platform and car size. D. Cylinder: G. Finished flooring. 1. Construction: Steel pipe with cylinder head having an H. Hydraulic tank heater. internal guide ring and self- adjusting packing. I. Electrical disconnects. 2. Safety valve: Cylinder shall be equipped with a pipe rupture safety valve to prevent uncontrolled car descent. PART 3 EXECUTION E. Plunger: 3.01 INSTALLATION 1. Construction: Shall be a machined steel shaft equipped A. Inspect the hoistway and determine if the hoistway meets the with a stop, electrically welded to bottom end, to prevent manufacturer's requirements for clearances and plumb. plunger from leaving cylinder shaft . B. All components shall be assembled and erected in strict 2. Diameter: 80 mm or 90 mm compliance with manufacturer's printed instructions and F. Suspension system: 1:2 system using (2) 3/8" 7x19 applicable codes. aircraft cables integrated with rams header sheave mounted to C. All wiring shall be in accordance with the wiring diagram the plunger. furnished by the manufacturer and the NEC. G. Guide rail: Shall consist of two 6 1/4 lb. tee rails assembled and fastened. Provide brackets to hold rail assembly to walls. 3.02 FIELD QUALITY CONTROL Rail shall be furnished with steel splice plates and hardware. A. Static /Running Load Test: All load rating and safety factors H. Car frame: Shall be equipped with non - metallic faced roller shall meet or exceed those specified in ASME A17.1. guide wheels. I. Leveling device: Provide Hall Effect Position Sensor to 3.03 ADJUSTING A. Test the elevator to assure proper operation under all conditions of use. Make proper adjustments and review operating components for proper operation. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 13 of 15 REV D 08.24.11 DM -204 Division 14235 Residential Elevator Winding Drum PART 1 GENERAL 2. Hoistway dimensions. 1.01 SECTION INCLUDES 3. Wiring diagrams. A. Residential elevator with inverter controlled winding drum. 4. Maintenance instructions. 5. Car and gate selection charts. 1.02 WORK INCLUDED A. Furnish all labor and materials, equipment and incidentals 1.07 QUALITY ASSURANCE necessary to assemble and erect a residential elevator, complete A. Qualifications: with a power unit and all rails, brackets, connections and controls Installer Qualifications: A company experienced in the assembly essential for proper operation. and erection of lifts and residential elevators of the type specified. Manufacturer Qualifications: A company specializing in the 1.03 WORK BY OTHERS manufacture of residential elevators. A. Construct a hoistway of the size required by the B. Regulatory Requirements: The complete manufacture, manufacturer, complete with all demolition, additional framing, fabrication and erecting of the elevator shall be in compliance headers and framing components necessary to prepare the with all Federal, State and Local codes and ordinances. The existing building to receive the elevator. installer shall verify requirements of the local authority having 1. Hoistway size: Dependent upon car size. jurisdiction and shall comply with all local codes and ordinances. 2. The hoistway shall be vertical to within 1/8" throughout the entire height. 1.08 DELIVERY, HANDLING & STORAGE 3. Provide and fasten vertical structural members in hoistway A. All components shall be shipped to the site in substantial per manufacturer's recommendation. crates to protect from damage during shipping and handling. 4. Pit requirements: Provide an 8" deep pit (6" deep Upon arrival, inspect components and keep under cover until minimum). Install reinforcement and concrete as necessary. installed. Floor must sustain load specified in job drawings. B. Construct a machine room: 1.09 WARRANTY 1. Provide elevator electrical circuit: 230 volt/1 phase /60hz A. Unit shall have a three (3) year limited parts warranty. (30 amp). 2. Provide elevator lighting electrical circuit: 115 volt 1.10 MAINTENANCE (15 amp). A. Maintenance of the private residential elevator shall consist of C. Provide system to maintain hoistway and machine room regular cleaning and inspection at intervals not longer than every temperature between 50 -90 degrees Fahrenheit. 12 months. B. Inspection: ASME A17.1 requires all private residential 1.04 REFERENCES elevators to be inspected every 12 months. A. General: The applicable provisions of the following standards shall apply as if written here in their entirety. PART 2 PRODUCTS B. American Society of Mechanical Engineers /American National 2.01 MANUFACTURERS Standards Institute (ASME /ANSI) publications: ASME /ANSI A. Manufacturer: "Destiny" model by ThyssenKrupp Access. A17.1 "Safety Codes for Elevators and Escalators ", Section 5.3. B. Substitutions: No substitution shall be considered unless C. National Fire Protection Association (NFPA) publications: written request for approval has been submitted and received by NFPA 70 National Electrical Code. the architect at least ten (10) days prior to the bid date. 1.05 SYSTEM DESCRIPTION 2.02 COMPONENTS A. Travel: (50' max.) A. Car: B. Stops: (up to 6) 1. Size 36 "W x 48 "D (others available) C. Load capacity: 950 Ib. or 750 Ib. 2. Enclosure: Securely fastened to the car frame and D. Speed: 40 fpm platform. The car shall be constructed of a minimum 3/4" wood walls. Floorboard shall be constructed of 3/4" AC 1.06 SUBMITTALS plywood. A. Submittals shall be in accordance with Section 01300, 3. Gate: Accordion equipped with a positively opened SUBMITTALS. mechanical switch to indicate that the door is closed. B. Product Data: Submit product data, including manufacturer's 4. Handrail: One, located on the car wall. specifications. 5. Telephone: Wall mount telephone jack shipped loose with C. Shop Drawings: elevator. 1. Shop drawings showing all field construction, including dimensions. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 14 of 16 REVD 08.24.11 DM -204 6. Control panel: Provide one momentary pressure N. "Self Diagnostic System" utilizing diagnostic codes displayed illuminated button for each landing, emergency stop and in hall and car acknowledgement lights to provide information in alarm button, and a digital position indicator; all mounted in the event the elevator will not operate. a control panel having a stainless steel or brass cover. 2.03 ACCESSORIES 7. Interior lighting: Provide overhead light fixtures that Specifier Note: Due to the individual nature of elevator automatically turn on when the car is in operation and turn installations, accessories such as, but not limited to those in the off by means of a timer circuit. following list are available. B. Hoistway Door: A. Hoistway doors and door locks. 1. Size: 3'0 "W x 6'8 "H swing type. B. Flush mounted telephone box. 2. The general contractor or owner is to furnish C. Car door finish and design. (elevator contractor may opt to furnish) and install hoistway D. Car operating panel and hall call finishes. doors, frames, hinges and passage sets at each landing. E. Car trim and wood specie. The F. Custom platform and car size. type and installation of the doors and frames must comply G. Finished flooring. with ASME A17.1, all local codes and manufacturer's H. Electrical disconnects. layout drawings. I. Battery lowering. 3. Locking Device: Door shall have a concealed locking device, interlocked with the car operation, to interrupt PART 3 EXECUTION electrical power when the door is not securely closed and a 3.01 INSTALLATION car is not at the landing. The door shall be locked when car A. Inspect the hoistway and determine if the hoistway meets the is not in the landing zone. manufacturer's requirements for clearances and plumb. C. Drive System: B. All components shall be assembled and erected in strict 1. Two speed inverter controlled winding drum unit. A single compliance with manufacturer's printed instructions and phase input, three phase output for soft start and soft stop. applicable codes. 2. The inverter shall be prewired, ready for connection to C. All wiring shall be in accordance with the wiring diagram the controller in the field. furnished by the manufacturer and the NEC. 3. Electromechanical brake with manual release. 4. Testing: Shall be factory tested prior to shipment. 3.02 FIELD QUALITY CONTROL D. Suspension System: (2) 3/8" 7x 9 aircraft wire rope. A. Static /Running load test: All load rating and safety factors E. Guide Rail: Shall consist of two 6 1/4 lb tee rails assembled shall meet or exceed those specified in ASME A17.1. and fastened. Provide brackets to hold rail assembly to walls. Rail shall be furnished with steel splice plates and hardware. 3.03 ADJUSTING F. Car Frame: Shall be equipped with non - metallic faced A. Test the elevator to assure proper operation under all conditions rollerguide wheels. of use. Make proper adjustments and review operation components G. Leveling Device: Provide Hall Effect Position Sensor to for proper operation. maintain car within 1/4" of the landing. H. Control Systems: Non - selective collective PLC. I. Motor: 3 HP, 1750 -RPM 208/230 VAC, three phase. J. Wiring: 1. Provide flexible traveling cable for electrical lights and controls in car. 2. All other electrical wiring shall be insulated, flame retardant and moisture proof copper wiring, installed in flexible metal conduit. K. Safety Devices: 1. Slack cable protection: Provide a stainless steel linkage device that stops and sustains the car in the event of breakage or slackening of cables. 2. Terminal stopping device: Shall be provided at the top and bottom of the car travel. 3. Provide a platform toe guard at the car entrance. 4. Final limits. L. Manual operation hand wheel is provided. M. Battery powered emergency operation system. 1. Powers a light in the car. 2. Powers an emergency alarm system. 3. The batteries shall be rechargeable type complete with an automatic recharging system. ©2011 ThyssenKrupp Access Corp. • 4001 East 138th Street • Grandview, MO 64030 • Phone: 800 - 829 -9760 • Fax: 816- 763 -4467 • Page 15 of 15 REV D 08.24.11 DM -204 �,y City of Atlantic Beach APPLICATION NUMBER 01,-,...), th �s , � Budding Department (To be assigned g b y y Building Department.) , . K 800 Seminole Road / 2 - d g - �"r Atlantic Beach, Florida 32233 -5445 Phone (904) 247 -5826 - Fax (904) 247 -5845 ®� I. D.F119 E -mail: building- dept @coab.us Date routed: City web -site: http: //www.coab.us APPLICATION REVIEW AND TRACKING FORM rtment review required Yep'No Building) Property Address: � • ���� e&� ,�DVi � q ✓✓ Applicant: fid G/ a- f*, va-/ I,L t h s Planning & Zoning � ,t_ Tree Administrator Project: 7j (I C"77 / 1 �� V��� Public Works Public Utilities Public Safety Fire Services K:41 +. C R ; : -, S fit "rgfaa r` "� c rI � x i .. � f~ 1..'sl� '�/ . Y ...CCC � Y: 4xn Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: A pproved. ['Denied. (Circl e.) Comments: BUILDIN PLANNING & ZONING Reviewed by: /7/ Date: 3 --/5 TREE ADMIN. Second Review: ['Approved as revised. ❑De ed. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ['Denied. Comments: Reviewed by: Date: 1 Revised 07/27/10