Loading...
Permit Mech 475 Skate Rd 2012 t s CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD till, ' ; . ATLANTIC BEACH, FL 32233 .......,, INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000336 Date 3/26/12 Property Address 475 SKATE RD Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor DODARO, NICHOLAS FLORIDA HOME DBA ARS 373 12TH STREET 4211 EMERSON ST ATLANTIC BEACH FL 322335537 DEFUNIAK SPRINGS FL 32435 (904) 777 -4300 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 95.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 9/22/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 95.00 95.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 99.00 99.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: '171 ,` - .1-c M , 04 n +; C. c,r I rL. 300R 3 3 PERMIT # PROJECT VALUE $ 3 600 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity i Tons Per Unit o2, 5 REQ RED Heat: Unit Quantity / BTU's Per Unit 11(oa, Seer Rating i 0 20 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty — Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: 1c)(01■L). Corn nil Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 0 t cf cAa e 0 Phone Number a53 - Ca l3 Mechanical Company f=/ ; r) i4o (Y) e Office Phone 3/`i Fax ')77 -9 5 9 Co. Address: e-47111 E mm e r son al"" City o,e, Lon.,' I le State FC Zip 3,9,,2o 7 License Holder (Print) A,r.: i Caw .� tate Certification/Registration # (° m c loci q q.. Notarized Signature of License Holder L 2 y� ,� l,, Sworn and subscribed befill. s S day of !t4 4C' 20 �1 6nm_, �"" "`°•' CAROLYN TURNER ' == ignature of Notary Publi MY COMMISSION # EE061381 pAstriat y r (i ±oso EXPIRES May 16, 2015 (407) 398 -0153 FloridallotaryService.com , ft eern DesignStar Satellite J Load Calculation Results are intended for use with Rheem heating and cooling systems only The New Degree of Comfort Customer Information Location: Street Address 475 skate rd, DUVAL, FL 32233 Latitude, Longitude 30.3375 °, - 81.7686° House Square Footage: 700 sq. ft Name: Nick Dadaro Phone: 904 -253 -0293 Email: example @mail.cc n Desi• n Conditions Outdoor Heating Cooling Dry bulb ( °F) 32 93 Daily range M Relative humidity 50% Moisture difference 53 Indoor Heating Cooling Indoor temperature (F) 70 75 Design temperature difference( °F) 38 18 Heatin• Loads Area Btuh % of load Wall 2021 12.7 Floor 5829 36.7 Ceiling 1410 8.9 Windows 1919 12.1 Infiltration 3265 20.6 System Efficiency Loss 1444 9.1 Total: ` 15889 Heating Loads 15,889 BTUIhr r Ceiling / System Efficiency Loss I Floor �\ i Windows 4* Wall Infiltration J Coolin • Loads Area Btuh % of load Wall 957 5.8 Ceiling 668 4 Windows 8816 53.4 Sensible Infiltraticn 1160 7 Latent Infiltration 2112 12.8 System Efficiency Gain 1371 8.3 Internal 785 4.8 Sensible People Load 322 1.9 Latent People Load 322 1.9 Total: 16513 Sensible load 14080 Latent Toad 2434 SHR 0.85 Capacity at .75 SHR 1.56 Tons Cooling Loads 16,513 BTU /hr Sensible People Load Latent People Load Ceiling !Ipik7v- --- Internal Wall . Sensible InfiltratiG I Windows 1 System Efficiency i \ Latent Infiltration Ade. uate osure Diversi AED Graph 15000 10000 to 5000 0 8am gam loam llam 12pm fpm 2pm 3pm 4p m 5pm 6pm 7pm 8pm — Hourly Loads — Average ACCA Manual S System equipment selection will be made using the fdlowing Manual S derived values. Summer Outdoor 93 °F Summer Wet Bulb 77°F Summer Indoor 75 °F Summer Design Grains 50% Winter Outdoor 32 °F Winter Indoor 70 °F Sensible Coding 14,080 Btuh Latent Coding 2,434 Btuh Required Coding Airflow 640 CFM Sensible Heating 15,889 Btuh Required Heaing Airflow 206 CFM All calculations based on the ACCA Manual J 8th Edition. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree 9. CERTIFIED www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4939870 Date: 3/7/2012 Product: Variable Speed Mini -Split Heat Pump, with Remote Outdoor Unit Air - Source, Free Delivery Outdoor Unit Model Number: MUZ- GEI8NA -1 Indoor Unit Model Number: MSZ- GEI8NA Manufacturer: MITSUBISHI ELECTRIC AND ELECTRONICS USA, INC. Trade /Brand name: MR. SLIM Manufacturer responsible for the rating of this system combination is MITSUBISHI ELECTRIC AND ELECTRONICS USA, INC. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 17200 EER Rating (Cooling): 10.50 SEER Rating (Cooling): 19.20 Heating Capacity(Btuh) @ 47 F: 21600 Region IV HSPF Rating (Heating): 10.00 Heating Capacity(Btuh) @ 17 F: 13400 CERTIFIED RATINGS FOR VARIABLE - SPEED, MINI- AND MULTI -SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS (BASED ON COMBINATION TYPES) WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED EQUIPMENT. VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON THIS CERTIFICATE IS ACCURATE. SEARCH ON THE AHRI REFERENCE # TO QUICKLY LOCATE THIS COMBINATION IN THE DIRECTORY. Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION um. The information for the model cited on this certificate can be verified at www.ahridirector Air Conditioning, Heating, click on "Verify Certificate" Zink and enter the AHRI Certified Reference Number and the date on A. IS -' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. 02012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129756082589717843