Loading...
Permit Mech 1861 Beachside Ct 2012 !.,x' ' CITY OF ATLANTIC BEACH c�? 800 SEMINOLE ROAD . � s) ATLANTIC BEACH, FL 32233 ' INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000271 Date 3/29/12 Property Address 1861 BEACHSIDE CT Application type description RESIDENTIAL OTHER Property Zoning TO BE UPDATED Application valuation . . . 10000 Application desc REMODEL HALL BATHROOM Owner Contractor WHITTINGTON WILLIAM R & NANCY OWNER 1861 BEACHSIDE CT ATLANTIC BEACH FL 32233 - -- Structure Information 000 000 REMODEL HALL BATHROOM Occupancy Type RESIDENTIAL Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 4 TON SYSTEM Sub Contractor . TROPIC HEATING & AIR Permit Fee . . . 107.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 9/25/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 107.00 107.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 111.00 111.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 1 ?CDI & d. 5;4- C.7 • PERMIT # PROJECT VALUE $ 7 d NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # 3 Air Conditioning: Unit Quantity / Tons Per Unit <7 REQUIRED Heat: Unit Quantity / BTU's Per Unit f..44J Seer Rating 6.. Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU' s Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: S,- ,./06.4. „e..ci ,--aq Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the perfonnance of construction. Property Owners Name <- i ti Phone Number -2 v'2 •/ 7 ) Mechanical Company -- 17 - 0 I \ C \ 6( Office PhoneZH Fax U' 2 i 7� • Co. Address: 7 5 J V' ff t' 7 � > City f L - ( a State F` (. Zip S 2 233 License Holder (Print): � t r.t'lr-.`L • (\ f' C- State Certification/Registration # CKO S ai-k3 I Notarized Signature of License Holder ae ; KAREN E. PANTFOEDER Sworn and subscribed before me this c:9 / day of /V) A rCh 2012- �` r NOTARY PUBLIC Signature of Notary Public �. 1 . . / /i - " '°. r , , STATE OF FLORIDA . IF "`t Comm# EE064448 Exp 3/4/2015 Job: ryat Project Summary Date: 3/28/2012 Entire House By: Brent Reedy IL t 446,7 4 Srtstets Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904- 241 -2172 Email: Brent.tropicacaatt.net Web: www.tropicheatandac.com License: CACO52431 .. T �. For: Colonel Whittington 1861 Beachside Ct., Atlantic Beach, FL 32233 Phone: 904- 242 -0170 Email: Tropicac@msn.com Notes: s des , nf+rm . Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 grab Heating Summary Sensible Cooling Equipment Load Sizing Structure 32630 Btuh Structure 28643 Btuh Btuh Ducts 0 Btuh Ducts Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment Toad 32630 Btuh Use manufacturer's data Y Rate /swing multiplier 1.00 Infiltration Equipment sensible Toad 28643 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2671 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 1925 1925 Equipment latent Toad 2671 Btuh Volume (f 17325 17325 Air changes/hour 0.38 0.20 Equipment total Toad 31315 Btuh Equiv. AVF (cfm) 110 58 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref no. n/a Coil AHRI ref no. Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 1304 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012- Mar -28 12:03:58 - WrigI`11'5Qft Comfort Builder by Wrightsoft 12.0.03 Right J® Mobile Page 1 -' V`` CAWINDOWS\ TEMP\ wstmp198dc9f15- d844- 488b- a240- 4a513ccf CaIc =MJ8 Front Door faces. N Right J® Mobile Report Date: 3/28/2012 i'� Entire House By: Brent Reedy tisitat 11Cortai Systems Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904 -241 -2172 Email: Brenttropicac@attnet Web: www.tropicheatandac.com License: CACO52431 ■ Pro * ect InforMation For: Colonel Whittington 1861 Beachside Ct., Atlantic Beach, FL 32233 Phone: 904- 242 -0170 Email: Tropicaccrosn.com Desi o n Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD (F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Method Simplified V■ibt bulb (°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 .. .. eat :n . Component Btuh/R Btuh % of load Walls 3.4 5073 15.5 yyry tiltraim Glazing 30.1 11389 34.9 ; / Doors 0 0 0 i 1- Ceilings 1.1 2131 6.5 Floors 5.1 9867 30.2 Infiltration 2.2 4170 12.8 Floas Ducts 0 0 �� Piping 0 0 Humidification 0 0 Ventilation 0 0 Csitrrgs Adjustments 0 Total 32630 100.0 • . in , Component Btu h/IF Btuh % of load Walls 1.5 2273 7.9 Irmrlal Ci s Glazing 53.4 20194 70.5 lnf' Itra6on Doors 0 0 0 .l Cg Ceilings 1.7 3252 11.4 Floors 0 0 0 Infiltration 0.5 1034 3.6 Ducts 0 0 Ventilation 0 0 Internal gains 1890 6.6 Blower 0 0 Adjustments 0 Gaarg Total 28643 100.0 Latent Cooling Load = 2671 Btuh Overall U -value = 0.143 Btuh/fta-- °F Data entries checked. 2012- Mar - 2812:03:58 :± wrightsoft Comfort Builder by Wrightsoft 12.0.03 Right JO Mobile Page 1 '.. -, C: IWINDOWSITEMP1wstmpt98dc9f15- d844- 488b- a240- 4a513ccf21fc.rup Cab =MJ8 Front Door faces: N Component Constructions Job: E li P4a n Date: 3/28/2012 Entire House By: Brent Reedy mil! Coal Sfttea Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beath, FL 32233 Phone: 904-241 -1788 Fax: 904- 241 -2172 Email: Brent.tropicac®attnet Web: www.tropicheatandac.com License: CACO52431 Pro ct nth , . - . For: Colonel Whittington 1861 Beachside Ct., Atlantic Beach, FL 32233 Phone: 904- 242 -0170 Email: Tropicac@msn.com D esign onditto Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 8.4 52.8 Dry bul b ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Method Simplified Vlkt bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain tP BMIW -°F ft"- "FBluh BUh4F Btuh BthflF Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int n 396 0.097 11.0 3.36 1328 1.50 595 fnsh, 2 "x4" wood frm e 360 0.097 11.0 3.36 1208 1.50 541 s 396 0.097 11.0 3.36 1328 1.50 595 w 360 0.097 11.0 3.36 1208 1.50 541 all 1512 0.097 11.0 3.36 5073 1.50 2273 Partitions (none) Windows 1D-c2om: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" n 99 0.870 0 30.1 2985 28.1 2785 gap, 1/8" thk a 90 0.870 0 30.1 2709 78.4 7060 s 99 0.870 0 30.1 2985 33.2 3289 w 90 0.870 0 30.1 2709 78.4 7060 all 378 0.870 0 30.1 11389 53.4 20194 Doors (none) Ceilings 16B -30ad: Attic ceiling, asphalt shingles roof mat, r -30 ceil ins, 1/2" 1925 0.032 30.0 1.11 2131 1.69 3252 gypsum board int fnsh Floors 22A -cph: Bg floor, heavy damp soil, on grade depth, carpet flr fnsh 210 1.358 0 47.0 9867 0 0 2012 - Mar -28 12:03:58 wrigl 1 soft Comfort Builder by Wrightsoft 12.0.03 Right J® Mobile Page 1 4 - - •' . . ; •' C:IWINDOWS\ TEMP\ wstmpt.98dc9f15- d644- 488b-a240- 4a5130cf2 Cak = MJ8 Front Door faces: N AED Assessment Job: b r i a r Date: 3/28/2012 Entire House By: Brent Reedy Natal • fli Systarts Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax 904- 241 -2172 Email: Brent.tropicac@att .net Web: www.tropicheatandac.com License CACO52431 1 Proectinformation' For: Colonel Whittington 1861 Beachside Ct., Atlantic Beach, FL 32233 Phone: 904- 242 -0170 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Vlkt bulb ( °F) - 77 Wind speed (mph) 15.0 7.5 r.for Ade taste' Ex `e Dkvty Hourly Glazing Load 28,000-- 24,111 22, 17 : ,- ~ "`° .,, 20,111 18,141 16,111 N, 14.111 ., ",;,. 12,11 10,••• 8,000 ;. 6,111 4,111 2,00- ;; = ; - -;- 1 -r— -7— ■ 1 I -i 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly Aerage / /limit Maximum hourly glazing load exceeds average by 19.4 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012- fytar- 2812.03 - ' +8 2 _.. 11" wrightsoft Comfort Builder by WrigMsoft 12.0.03 Right J® Mobile Page 1 A -'. C. \ WINDOWS\ TEMP1wstmp\ 98dc9f15- d644- 488b- a240- 4a513ccf2 Calc = MJ8 Front Door faces N iset Right -J® Worksheet Job: Entire House Date: 3/28/2012 wary a .4 s.. By: Brent Reedy Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904-241-2172 Email: Brent.tropicac@att.net Web: www.tropicheatandac.com License: CACO524... 1 Room name Entire House First Floor 2 Exposed wall 210.0 ft 210.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions z 1.0 x 1925.0 ft 5 Room area 1925.0 f 1925.0 ft 1 1 1 l r Ty Construction U -value Or I HTM I Area (ft') ( Load I Area (ft') ( Load number (Btuh /ft' - ° F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I Heat I Cool I Gross I N/P /S Heat I Cool I Gross ! N/P /S Heat I Cool I 6 Vy 12B -Obw 0.097 n 3.36 1.50 495 396 1328 595 495 396 1328 595 L—_ 1D -c2om 0.870 n 30.10 28.08 99 0 2985 2785 99 0 2985 2785 128-Obw 0.097 e 3.38 1.50 450 360 1208 541 450 380 1208 541 1D -c2om 0.870 e 30.10 78.45 90 0 2709 7060 90 0 2709 7060 11 vy 12B -Obw 0.097 s 3.36 1.50 495 396 1328 595 495 396 1328 595 L G 1D -c2om 0.870 s 30.10 33.16 99 0 2985 3289 99 0 2985 3289 Wly 12B -Obw 0.097 w 3.36 1.50 450 360 1208 541 450 360 1208 541 Lam, 1D-c2om 0.870 w 30.10 78.45 90 0 2709 7060 90 0 2709 7060 C 168 -30ad 0.032 - 1.11 1.69 1925 1925 2131 3252 1925 1925 2131 3252 F 22A -cph 1.358 - 46.99 0.00 1925 210 9887 0 1925 210 9867 0 6 1 0 0 Envelope I I I 284611 25720) 28461 25720 I c) AED excursion Pe loss/gain 12 a) Infiltration 4170 1034 4170 1034 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 1200 1200 Subtotal (lines 6 to 13) 32630 28843 32630 28843 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32630 28643 32630 28643 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 I T Air reqotal roo uired m ba (cfm ) I ( I ( 326301 23 1 I I 3263 281643 I Calculations approved by ACCAto meet all requirements of Manual J 8th Ed. wrtght aft 2012- Mar - 2812:03:58 Comfort Builder by Wrightsoft 12.0.03 Right J® Mobile Page 1 %<. CA WINDOWS\ TEMP1 wstmp198dc9f15- d644- 488b- a240- 4 a5 13 ccf 21 fc.rup Cab = MJ8 Front Door faces: N