Loading...
Permit Mech 1306 Beach Ave 2012 5 CITY OF ATLANTIC BEACH ; -, j 800 SEMINOLE ROAD 3 - ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 4 J13/ Application Number 12- 00000369 Date 4/02/12 Property Address 1306 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor GREENE C CAMERON & KIM SMITH TROPIC HEATING & AIR 1306 BEACH AVE 750 MAYPORT RD ATLANTIC BEACH FL 322335732 ATLANTIC BEACH FL 32233 (904) 241 -1788 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 87.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 9/29/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 87.00 87.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 91.00 91.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: /c26 f «-o4. lee PERMIT # PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 38216'0/ Air Conditioning: Unit Quantity / Tons Per Unit / • s REQUIRED Heat: Unit Quantity / BTU's Per Unit S' / Seer Rating X95 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name G:r Phone Number ,PZI I Mechanical Company m/'iL _ Office Phone 1 Fax Co. Address: 7(Y (��� ^ 2 ) City Pj\k. ( Stater( - Zip 3 t2 3 License Holder (Print): '`4-&. , State Certification/Registration # C /IC PS2y Notarized Signature of License Holder - 11' KAtteu l".. PANTINOEDER '+,{ NOTARY PUBLIC Sworn and sub IIV 'bed before me this '' day of Pion ! 20 1 Z ,+� STATE OF FLORIDA .�': � ` Comm# EE064448 Signature of Notary Public 74W-9t- • " Expires 3/4/2015 A19R1 CERTIFIED TM www.ahriditectory.org Cp.rtifieatp of Product Ratings AHRI Certified Reference Number: 3829809 Date: 3/30/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 215BNA018""A Indoor Unit Model Number: FB4CNF018 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade /Brand name: LEGACY 15 PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 17700 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh) @ 47 F: 18000 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 10700 Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which Indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at u,.,...,. •8._tory.::ry. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION U �, The infomation for the model cited on this certificate can be verified at -:w.ahridirectory.org, Air-Conditioning, Heating, click on " " link and enter the AHRI Certified Reference Number and the date on A . SR •' a nd Refrigeration Institute which the certificate was issued, which is listed above.. and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration institute CERTIFICATE NO.: 129776037103967154 b p V � � � . Summary Date: Project Summa 1 , � ' J Date: 3/30/2012 j Entire House By: Brent Reedy Neil( II Itinters Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax: 904-241-2172 Emait BrenttropicacOattnet Web: www.tropicheatandac.com License: CACO52431 Pro'ect Information For: Dr.cameron Green 1306 Beach Ave., Atlantic Beach, FL 32233 Phone: 904 - 249 -7509 Email: Tropicac@msn.com Notes: Desi • n information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14803 Btuh Structure 12043 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14803 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible Toad 12043 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1461 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 500 500 Equipment latent load 1461 Btuh Volume (f 4500 4500 Air changes /hour 0.61 0.32 Equipment total load 13504 Btuh Equiv. AVF (cfm) 46 24 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref no. n/a Coil AHRI ref no. Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 548 cfm Air flow factor 0 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i -+ - wrightsoft Comfort Builder by Wrightsoft 12.0.03 Right J® Mobile 2012- Mar -30 14P Page 1 4-:(---4 C:\ WI NDOWS\ TEMP\ wstmp\ 0905118a- 954d- 48ff- b7fl- ddfd954e234a.rup CaIc = MJ8 Front Door faces N Right J® Report Job: Eh ! p } 9 P Date: 3/30/2012 (� Entire House By: Brent Reedy N. ig II Whig irises Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone 904- 241 -1788 Fax: 904- 241 -2172 Email: Brent.tropicac@att . net Web: w.vwtropicheatandac.com License: CACO52431 ' - do-, 6 i ` '' ,�?�, 1 " . , s -: ai 'j";,s 3 --�. 1`J � Er`.a i� 4:V 3 yam ' �9 .-7,4,. , . 7 �� 3 �F' ' '✓ 3 # ,x ws F a .. e.., fi :7 ( w r ' "� -.. - ;U'.E' T'!..2 5. jx''t: g For: Dr.cameron Green 1306 Beach Ave., Atlantic Beach, FL 32233 Phone: 904 - 249 -7509 Email: Tropicaci§msn.com Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 ( M ) Method Simplified 1/lkt bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft Btuh % of Toad Walls 7.5 5198 35.1 / Irill�m Glazing 30.1 3637 24.6 Doors 0 0 0 VVlis Ceilings 0 0 0 _ Floors 8.5 4229 28.6 Fkx s Infiltration 2.1 1739 11.7 i Ducts 0 0 Piping 0 0 ' Humidification 0 0 Ventilation 0 0 G rg Adjustments 0 Total 14803 100.0 Coolin • Component Btuh/ft Btuh % of load Walls 3.5 2419 20.1 Glazing 60.5 7305 60.7 VEIIs / I lard Ctrs Doors 0 0 0 . Ceilings 0 0 0 Floors 0 0 0 f Infiltration 0.5 430 3.6 Ducts 0 0 Ventilation 0 0 Internal gains 1890 15.7 Blower 0 0 Adjustments 0 Total 12043 100.0 C3arQ Latent Cooling Load = 1461 Btuh Overall U -value = 0.209 Btuh /ft - °F Data entries checked. -{ " - �t" - 2012- Mar -30 14:26:04 t- wrightsoft Comfort Builder by Wrghtsoft 12.0.03 Right J® Mobile Page 1 C:\ WINDOWS\ TEMP\ wstmp\ 0905118a- 954d- 46ff- b7fl- ddfd954e234a.rup CaIc = MJ8 Front Door faces: N 01 4-111-0 Right -J® Worksheet Job: y Entire House Date: 3/30/2012 Noel/ a 6 rryisr+o By: Brent Reedy Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904- 241 -2172 Email: Brent.tropicac@att.net Web: www.tropicheatandac.com License: CACO524... 1 Room name Entire House First Floor 2 Exposed wall 90.0 ft 90.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 25.0 x 20.0 ft 5 Room area 500.0 ft' 500.0 ft' r 1 1 1 1 Ty Construction U -value Or HTM Area (ft') Load Area (ft') Load number (Btuh /ft' - °F) ( (Btuh/ftl I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P /S Heat Cool Gross N/P /S Heat Cool 6 Vi! 14E -2 0.218 ne 7.54 3.51 180 153 1157 538 180 153 1157 538 L _G 1D-c2om 0.870 ne 30.10 59 00 27 0 803 1573 27 0 803 1573 . \ / 14E -2 0.218 se 7.54 3. 51 225 191 1443 671 225 191 1443 671 1D-c2om 0.870 se 30.10 61.91 34 0 1016 2089 34 0 1016 2089 11 Vi/ 14E -2 0.218 sw 7.54 3.51 180 153 1157 538 180 153 1157 538 1 — 1D-c2om 0.870 sw 30.10 61.91 27 0 803 1651 27 0 803 1651 Vy 14E -2 0.218 nw 7.54 3.51 225 191 1443 671 225 191 1443 671 L—G 1Qc2om 0.870 nw 30.10 59.00 34 0 1016 1991 34 0 1016 1991 C Celli 0.000 - 0.00 0.00 500 500 0 0 500 500 0 0 F 22A -cph 1.358 - 46.99 0.00 500 90 4229 0 500 90 4229 0 • 6 Envelope loss /gain I I I 130641 97241 13064 1 9724 12 a) Infiltration 1739 430 1739 430 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants t. 8 230 3 690 3 690 Appliances/other 1200 1200 Subtotal (lines 6 to 13) 14803 12043 14803 12043 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14803 12043 14803 12043 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 T Air otal req m b(cad m) I I l I 148030 120431 I I 148001 12 548 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wright e ft 2012- Mar- 3014:26:05 Comfort Builder by Wrghtsoft 12.0.03 Right J® Mobile Page 1 C: WINDOWS\ TEMP\ wstmp\ 0905118a- 954d- 46ff- b7fl- ddfd954e234a. rup CaIc = MJ8 Front Door faces: N Comonent Constructions Job: }� �t tl! 1+ p Date: 3/30/2012 IJ 1 i� Entire House By: Brent Reedy rii Wig &big Wiwi Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax: 904- 241 -2172 Email: Brent. tropicac©attnet Web: www.tropicheatandac. License: CACO52431 Pro'ect Information For: Dr.cameron Green 1306 Beach Ave., Atlantic Beach, FL 32233 Phone: 904- 249 -7509 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grllb) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 ( M ) Method Simplified Vlkt bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain fF Bbh/fF -- °F ft'-° FBUh BhfirIF Btuh Bhhm' Btuh Walls 14E -2: Blk wall, r -2 ext bd ins, 8" thk ne 153 0.218 2.0 7.54 1157 3.51 538 se 191 0.218 2.0 7.54 1443 3.51 671 sw 153 0.218 2.0 7.54 1157 3.51 538 nw 191 0.218 2.0 7.54 1443 3.51 671 all 689 0.218 2.0 7.54 5198 3.51 2419 Partitions (none) Windows 1 D -c2om: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" ne 27 0.870 0 30.1 803 59.0 1573 gap, 1/8" thk se 34 0.870 0 30.1 1016 61.9 2089 sw 27 0.870 0 30.1 803 61.9 1651 nw 34 0.870 0 30.1 1016 59.0 1991 all 121 0.870 0 30.1 3637 60.5 7305 Doors (none) Ceilings Celli : Ceil1 500 0 0 0 0 0 0 Floors 22A -cph: Bg floor, heavy damp soil, on grade depth, carpet fir fnsh 90 1.358 0 47.0 4229 0 0 + wri ht ft 2012 -Mar - 3014:26:05 9 Comfort Builder by Wrightsoft 12.0.03 Right JO Mobile Page 1 - ' C:\ WINDOWS\ TEMPl wstmp1 0905118a- 954d- 46ff- b7f1- ddfd954e234a.rup Calc =MJ8 Front Door faces: N Job: dP AED Assessmen Date: 3/30/2012 Entire House By: Brent Reedy ""*` Wig irtair Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904- 241 -2172 Email: Brent.tropicacatattnet Web: www.tropicheatandac.com License: CACO52431 Project Information For: Dr.cameron Green 1306 Beach Ave., Atlantic Beach, FL 32233 Phone: 904 - 249 -7509 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grllb) 8.4 52.8 Dry bul b ( °F) 35 91 Infiltration: Daily range ( °F) - 17 ( M ) 'A tbulb( °F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 9, 001 8,001 7,001 6,001 5,001 4,001 3,001- 2,001 1,001 0 - - -t - I I I 1 1 I 1 I 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day l-buiy Aerage PIED limit Maximum hourly glazing Toad exceeds average by 20.7 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012 -Mar - 3014.26:05 wrightsoft Comfort Builder by Wrightsoft 12.0.03 Right J® Mobile Page 1 - - C: \WINDOWS\TEMP\ wstmp\ 0905118a- 954d- 46ff- b7fl- ddfd954e234a.rup Calc = MJ8 Front Door faces: N