Loading...
Permit Mech 1897 Beach 2012 : . \ \t . CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 0 v .,. ,., ATLANTIC BEACH, FL 32233 A'" .., INSPECTION PHONE LINE 247 -5814 �JlS Application Number 12- 00000368 Date 4/02/12 Property Address 1897 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor STEELE ALLEN J TUST OCEAN STATE HEAT & AIR, INC. 7174 RAMOTH DRIVE 1476 ATLANTIC BLVD. JACKSONVILLE FL 322263245 NEPTUNE BEACH FL 32266 (904) 249 -8251 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 9/29/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 V� 'D Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: ( 9 7 a f . e, )a∎L Al L PERMIT PROJECT VALUE $ 5- 3 (0 4 b 0 NEW AIR CONDITION LNG & HEATLNG SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM v REOUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# ( 32YOz9 Air Conditioning: Unit Quantity 1 Tons Per Unit 3 REQUIRED Heat: Unit Quantity 1 BTU's Per Unit /o / Seer Rating /Y Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser B I Li's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby_ certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name A-1 let -zvkt- Phone Number A. if - C, CJ 7 - - Mechanical - eompany - - {n - e - _T - 4- ,4 Y Office Phone ZY F -32 . 5 - 1 Fax 2 v - 4f Y 4 Co. Address: l V 7 ( - F(6,kt - !Al v ' , City Tf 901 - u . . /� � State ft Zip , � 2. z3 3 License Holder (Print): J "c.,- Tet r 1,_ A ication/Registration n CAC-0497k/ U Notarized Signature of License Holy • - 1 .Z'' _�� = rA n �" yVET I E P. MO o,,, c �t5rn and subscri , - me this �� day of ) ` `f to 20 )Z u 4 "� "".. Comm# DD086053 : yF % Signature of Notary Public yilf)0(a..6A./ p.m ,s � '" U Expires 3/2/2013 "2 Gc t` -�;o` Florida Notary Assn., Inc , X 4,11104 11 ACCA Manual "J" Heat Load Calculation Date 03/27/12 Customers Name - k --- e...� _ �_G- Location j4+ 8-c.¢,. Type of Construction Heat Transfer Multipliers Area or B UH Exposure Notes HEATING COOLING Length HEATING COOLING 1 Gross Wall 1,503 2,3 Windows North Ai, N, 2 29.0 16.0 35 1,015 560 East & West Al. E & W. 2 29.0 46.0 112 3,248 5,152 South Al, S. 2 29.0 25.0 40 1,160 1,000 4 Doors Front Solid Wood - Panel 27.0 15.8 30 810 474 Patio Solid Wood - Storm 16.4 9.7 60 984 582 Other Sldg GI Dr. S. 2 32.6 25.0 0 0 0 5 Net Wall Area 1 R- 11, 1/2" Asp. Brd. 3.2 1.9 1.226 3,923 2.329 Area 2 R- 13, 1/2" Asp. Brd. 3.0 1.8 0 0 Area 3 R- 13. 1/2" Asp. Brd. 3.0 1.8 0 0 6 Ceilings Area 1 Attic, R- 22 1.9 2.1 1.872 3,557 3,931 Area 2 Attic. R- 19 2.1 2.3 0 0 Area 3 Attic, R- 19 2.1 2.3 0 0 7 Floors Area 1 Slab 40.5 0.0 167 6,764 0 Area 2 None 0.0 0.0 0 0 8 Infiltration Winter Summer Avg Ciing Ht Poor 1500 - 2100 1.2 0.6 10 20,633 4.127 9 Sub Total BTUH Loss 42,094 10 Duct BTUH Loss 4,209 11 TOTAL HEATING LOAD 46,303 12 People and Appliances Bedrooms 4 3,600 13 Sub Total BTUH Gain (Structure) 21.755 14__ Duct- - BT-UH _Gain- Location Attic 15% 3,263 15 TOTAL SENSIBLE 25,019 16 Infiltraton Latent Gain Infit. CFM 188 6,505 17 People Latent Gain # People 6 3.000 19 TOTAL LATENT 9.505 19 Total Cooling Load I 34,524 ru.. l CERTIFIED. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 1384029 Date: 3/30/2012 Product: Split System: Heat Pump with Remote Outdoor Unit- Air - Source Outdoor Unit Model Number: 4TWX5036A1 Indoor Unit Model Number: 4TEE3F37B1 Manufacturer: TRANE Trade /Brand name: XL15I WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 34800 EER Rating (Cooling): 11.80 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 37600 Region IV HSPF Rating (Heating): 7.80 Heating Capacity(Btuh) @ 17 F: 24000 " Ratings followed by an asterisk ( "j indicate a voluntary rerate of previously published data, unless accompanied with e VIAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for. the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate, Certified ratings are valid only for models and configurations listed in the directory at w I.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION ��® The information for the model cited on this certificate can be verified at wwwahridirect:ory,org, Air-Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on AMR ■N 1/ which the certificate was issued, which is listed above. and the Certificate No., which is listed below. Land Reftigefatton Institute ©2012 Air- Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129776200515575452