Permit Mech 1543 Main 2012 lO' ./" �, r r� CITY OF ATLANTIC BEACH A°"` r 800 SEMINOLE ROAD \\\ " ATLANTIC BEACH, FL 32233 \ INSPECTION PHONE LINE 247 -5814 N 1. o.a19' Application Number 12- 00000395 Date 4/09/12 Property Address 1545 MAIN ST 1543 Tenant nbr, name 1543 GENERAL DYNAMICS Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 8350 Application desc REPLACE 5 TON SYSTEM Owner Contractor PAR PRO LTD ONE HOUR AIR P 0 BOX 330177 1015 ATLANTIC BLVD 4249 ATLANTIC BEACH FL 322330177 ATLANTIC BEACH FL 32233 (904) 222 -8482 Permit MECHANICAL HVAC PERMIT Additional desc . REPLACE 5 TON SYSTEM Permit Fee . . . 115.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/06/12 Special Notes and Comments NEED RECORDED NOC PRIOR TO FIRST INSPECTION Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 115.00 115.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 119.00 119.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION vi /lk ("iv--d CITY OF ATLANTIC BEACH D 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: i 5 z vi4/7jn) 1 PERMIT # /4) - 3'S PROJECT VALUE $ _P ARI # cjR %0 — 2 R REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating 1, Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) ,J0 0 e Fire Suppression Systems Quantity (Requires 3 sets of plans) n j,/‘.., FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts - Gas Piping Outlets Boilers iTTUT ) j Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps A # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name (-- 4 L DyA x,441 ( C Phone Number 7, 1 ( 3 6 ° j Mechanical Company 0 0 4 t/ /, ( Office Phone 29)-3 ICS 7Fax 2 t_/ '7-S:5-26 Co. Address: 1 • • /I A PI f_o City ti C 1 . State Ft- Zip 2 2 .73 License H el A A ,; ' -i ,aztfro) _ 1.,0 , St. ificat' s n/Registration #Ci ( /8/ 9 7 ---C, Notarized ' 7� , • ; res tiler _ /_ I " L. Ar worn and subscribed be 'ore this da of �` /� _ 20, ( Signature of Notary Public �� ' i %r f_� L ET /0G V7 led. 0 wrightsok Project Summary Job: 117781 Entire House Date: 4/5/2012 By: ONE HOUR AIR 1198 MAYPORT RD #1, ATLANTIC BEACH, FL 32233 Phone: 904 - 241 -3107 Fax: 904 - 247 -5526 License: CAC1814420 Project Information For: GENERAL DYNAMICS 1543 MAIN ST, ATLANTIC BEACH, FL 32233 �fa 24t -(o3G Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 62488 Btuh Structure 49239 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 62488 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible Toad 49239 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Loose Fireplaces 0 Structure 7810 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 3600 3600 Equipment latent load 7810 Btuh Volume (ft 32400 32400 Air changes /hour 0.58 0.30 Equipment total load 57049 Btuh Equiv. AVF (cfm) 313 162 Req. total capacity at 0.90 SHR 4.5 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade ONE HOUR AIR Trade ONE HOUR AIR Model GSZ130604 Cond GSZ130604 AHRI ref no. 3896078 Coil AHRI ref no. 3896078 Efficiency 0 HSPF Efficiency 13 SEER Heating input Sensible cooling 51528 Btuh Heating output 0 Btuh @ 47 °F Latent cooling 5472 Btuh Temperature rise 0 °F Total cooling 57000 Btuh Actual air flow 2242 cfm Actual air flow 2242 cfm Air flow factor 0.036 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +: W ril �1t SC�ft° 2012- Apr -05 09:24:24 Right - Suite® Universal 2012 12.0.03 Right Je Mobile 10-64. C: \WINDOWS\ TEMP\ wstmp\ 9430d29b- d2cd- 4c19- b25a- 94da27d2dcde.rup Calc = MJ8 Front Door faces: N Page 1 A1 9 R 1 CERTIFIED,. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3896078 Date: 4/9/2012 Product: Split System: Heat Pump with Remote Outdoor Unit- Air - Source Outdoor Unit Model Number: GSZ130604A* Indoor Unit Model Number: AR *F486016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 57000 EER Rating (Cooling): 11.10 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 58000 Region IV HSPF Rating (Heating): 8.20* Heating Capacity(Btuh) @ 17 F: 36000 • Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION s Immo! The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on `Verify Certificate" link and enter the AHRI Certified Reference Number and the date on Imam Air - Conditioning, Heating, which the certificate was issued, which is listed above, and the Certificate No., which is listed below. and Refrigeration Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129784526298632760 APR -26 -2012 15:34 FROM: CLERK OF COURTS 904 270 1512 T0: 92475845 P:1 1 Doc # 2012092340, OR BK 15926 Page 292, - Number Pages 1 ' Recorded 04 at 03:55 PM, $10.00 _ - _ JiNS FULLFR CLERK CIRCUIT COURT DUVAL No. 1 2- a S F CORDlNRY R�COr, NOTICE OF COMMENCEMENT STATE OF FLORIDA COUNTY OF DUVAL / ST JOHNS / CLAY ' r THE UNDERSIGNED hereby gives no(ice that improvement will be made to certain real property, and in accordance with Chapter 713, !rids. Statutes, the following information is provided in this Notice of Commencement. 1. Description of property (legal description and street address, if available): / 5 //1 ( i 4 t L - 2- General description of improvement: New 11V • C • ui •ment 2-2, 3. Owner information: a). Name and address: • ; 1 a * 1 4 C r A I rtr lie b) Irfierest in property: n c) Name and address of fee siwple title holder (if other than Owner) - e _________________ . . 4, Contractor (name and address): buts nit ',LC dba On Hoar Air (preared By) nn 1198 a n t ltd Suite tlan T3each, I L 32233 `G 5. S _ a) Marne and" address: - b) Amount of bond- $ • 6. Lender (name and address): 7. Persons within the State of Florida designated by Owner upon whore notices or other documents may be servcd.as provided by section 713.13(1)(a)7., Florida Statutes (name and address) 8. In addition to hir Owner designates - of (address) to receive a copy of the Lienor's Notxee as provided in section 71:3.13(1)(b), Merida Statute. . 9. Expiration date of notice of commencement (the expiration date is one year from the date of recording unless a different date is specified): _ • - • , AM • . • (Signature of Owner) 1 • ' T . Print Marne • CA'S'S 111 Address: 1 4 3 144 t/ 1 S A Al • I 1 L X 223 STATE OF FLORIDA • COUNTY OF DUVAL / ST JOHNS / CLAY SWORN TO and subscribed before me this 7 d ay of gtlitil _ , 20 (2 by '' " T i 5 / least check as ] (name) He/She [p applicable 1 / is personally 'mown to me, or has prod ced / / hi (state) driver's license, or /- / his/her (�* _ :f •-r tihication) as ides tiltcation. I . - . _ _ - fi r ` �' t / ,irt" `, C R A 1G F E DDY - % .�r�l sL�r i= Camml$sion 0 DD 959227 � _ • my commission Expires _ rain F Eddy t February 07, 2014 (Printed Name) NOTARY PUBLIC, STATE OF FLORIDA _ _ February 7, 20X4 (Commission Expiration Date) .�