Permit Mech 331 10th St 2012 61: , y ,f CITY OF ATLANTIC BEACH 54 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 1,JJ3 ' ' INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000425 Date 4/12/12 Property Address 331 10TH ST / /12 Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor DURHAM LAUREL FLINT CONSTRUCTION SVCS (HVAC) 331 10TH STREET 1419 LINKSIDE DRIVE ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 994 -9626 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date . . 10/09/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: ? 3 / /0 .l4 Si' PERMIT # PROJECT VALUE $ ?� S n'. `i`' ARI # ? ?- 6 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity / Tons Per Unit 3 Heat: Unit Quantity 1 BTU's Per Unit . 6 k Seer Rating 1� 5 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name La ui / Dv4 114 Phone Number 6G a - cisT q' Mechanical Company T te r"- 57 " o H Se". (-7 (es Office Phone r9 c‘ K.20 Fax 1 ?° 'o // Co. Address: /�{✓4' t its 1r,(, City ,/� T/( Abc-4 State i( Zip /4) ?T License Holder (Print): / 4 , St e rtification/Registration # Cif ?/&2 P3 Notarized Signature of License Holder ' ;: e > .6.,�..�prllei before m- a da o Wm . - 20/1 MY ' COMMISSION & DO 957760 , � I. , .si ' ,blic ` 4 - ;land ?d Th ru N otary u il'C lIn Q wrightsoft n'y "L o Iwvune neput 1. Entire House Date: 4/12/2012 Flint Construction Services By: Russell Flint 1419 Linkside Dr., Atlantic Beach, FL 32233 Phone: 904.994.9626 Fax: 904.372.9011 Email: flintr@comcasst.net Web: www.flintcon.com License: CAC1816283 ■ Pro Information For: Laurel Durham 331 10th Street, Atlantic Beach, FL 32233 Phone: 904.864.0889 Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Dailyrange ( °F) - 17 ( M ) Method Vlktbulb ( °F) - 77 Simplified Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft Btuh % of load Walls 7.0 9239 39.4 Infiltraicn Glazing 19.7 3353 14.3 Doors 13.5 425 1.8 Ceilings 1.7 2543 10.8 Floors 2.7 4048 17.3 Bars Infiltration 2.5 3848 16.4 Ducts 0 0 Piping 0 0 Humidification 0 0 Clams Ventilation 0 0 Qazirg ahr Adjustments 0 Total 23456 100.0 Coolin • Component Btuh/ft Btuh % of load Walls 4.1 5394 25.1 Irternl Gars Glazing 48.9 8313 38.6 vl Irfiltraticrt Doors 11.4 360 1.7 Ceilings 2.1 3146 14.6 Flours Floors 1.0 1498 7.0 Infiltration 0.6 926 4.3 Ducts 0 0 Ceilings Ventilation 0 0 Internal gains 1890 8.8 Blower 0 0 Cther Adjustments 0 Gaing Total 21527 100.0 Latent Cooling Load = 2456 Btuh Overall U -value = 0.125 Btuh /ft - °F Data entries checked. wrightsoft 2012- Apr -12 07:34.50 Right - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 474'. C: \WINDOWS\ TEMP \wstmp\22d9cbe1- c4e3 -4b29- 8469 -0323fd0272c4.rup Calc = MJ8 Front Door faces: N wrightsoft rroject a ___ Entire House Date: 4112/2012 Flint Construction Services BY Russell Flint i 1419 Linkside Dr., Atlantic Beach, FL 32233 Phone: 904.994.9626 Fax: 904.372.9011 Email: flintr @comcasst.net Web: www.flintcon.com License: CAC1816283 Pro'ect Information For: Laurel Durham 331 10th Street, Atlantic Beach, FL 32233 Phone: 904.864.0889 Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db Outside db 35 °F 91 °F Inside db Inside db Design TD 35 °F Design TD 75 6 °F Daily range M Relative humidity 50 % Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23456 Btuh Structure 21527 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23456 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 21527 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2456 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 1500 1500 Equipment latent load 2456 Btuh Volume (ft') 13500 13500 Air changes /hour 0.45 0.23 Equipment total load 23983 Btuh Equiv. AVF (cfm) 101 52 Req. total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 0 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.042 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right - Suite® Universa1201212.0.04 Right JO Mobile 2012- Apr - 1207:34:50 ' '' A C:\ WINDOWS \TEMP \wstmo\22d9cbel- c4e3 -4b29- 8469- 0323fd0272c4.ruo Calc = MJB Front Door faces: N Page 1 • i• WV 1 .9111...7k./1.. vv • • v. .w• Entire House Date: 4/12/2012 Flint Construction Services BY Russell Flint 1419 Linkside Dr., Atlantic Beach, FL 32233 Phone: 904.994.9626 Fax: 904.372.9011 Email: flintr @comcasst.net Web www.flintcon.com License: CAC1816283 1 Room name 2 Exposed wall Entire House First Floor 3 Room height 170.0 ft 170.0 ft 4 Room dimensions 9.0 ft 9.0 ft heat/cool 5 Room area 1.0 x 1500.0 ft 1 t 1500.0 ft' 1500.0 f t' Ty Construction U -value Or number (Btuh /ft' - °F) I (Btuh/ft' ) I Area (f t') I Load I Area (f t') I Load I I or perimeter (ft) (Btuh) or perimeter (ft) Load (Btuh) Heat I Cool Gross I N /P /S I Heat I Cool Gross I N /P /S I Heat 1 Cool 6 13A -2ocs 0.201 n 6.95 4.06 270 240 1669 I 1 D -c2ow 0.570 n 19.72 20.91 30 0 592 627 3 974 270 240 1669 974 . V) 13A -2ocs 0.201 e 0 0 592 627 L_� 6.95 4.06 495 440 3060 1786 495 440 1 D -c2ow 0.570 e 19.72 63.01 55 0 3060 1465 11 13A -2ocs 0.201 s 6.95 4.06 1450 3847 55 0 1085 3465 1D -c2ow 270 209 1450 847 270 209 1450 847 0.570 s 19.72 25.16 30 0 592 755 30 D 1100 0.390 s 13.49 11.43 32 32 425 360 32 32 592 755 425 360 VI— G 13A -2ocs 0.201 w 6.95 4.06 495 440 3060 1786 495 440 3060 1786 1D-c2ow 0.570 w 19.72 63.01 55 0 1085 3465 55 0 1085 65 C 16C -19a1 0.049 - 1.70 2.10 1500 1500 2543 3146 1500 1500 2543 3146 F 20P -11t 0.078 - 2.70 1.00 1500 1500 4048 1498 1500 1500 4048 1498 6 c) AED excursion Envelope loss /gain 1 1 1 196081 187101 1 19608 1 18710 1 12 a) Infiltration b) Room ventilation 3848 9260 3848 926 0 0 13 Internal gains: Occupants @ 230 3 690 3 Appliances /other 1200 690 1200 Subtotal (lines 6 to 13) 23456 21527 23456 21527 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 23456 21527 15 Duct loads 0% 0% 0 0 -0% 0 23456 21527 0 A otal roomedl (gym) I I I 234561 21527 I I 1 23456 980 I 21527980 1 980 980 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t s wrightsoff Rig ht-Suite® U niv ersal 2012 12.0.04 Right J® Mobile 2012- Apr - 1207:34:50 �k _._..._.__.. __. -_. ._. Page 1 +'+ wrightsoft L,omponent I. _._. Entire House Date: 4/12/2012 Flint Construction Services BY Russell Flint 1419 Linkside Dr., Atlantic Beach, FL 32233 Phone: 904.994.9628 Fax: 904.372.9011 Email: flintr @comcasst.net Web: www.flintcon.com License: CAC1816283 Pro'ect Information For: Laurel Durham 331 10th Street, Atlantic Beach, FL 32233 Phone: 904.864.0889 Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Elevation: 43 ft Indoor temperature ( °F) 70 75 Elevation: 30 °N Design TD ( °F) 35 16 Outdoor: Relative humidity ( %) 30 50 Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Drybulb ( °F) 35 91 Infiltration: ar Daily nge ( °F) _ Daily ra n e - 17 ( M ) Method Simplified Wind speed (mph) 15.0 5 7.5 Fireplaces quality Average Fireplalaces s 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain ft' Btuh/1f' -°F ft'-'F/Btuh Btuh/ft' Btuh Btuh/IP Btuh Walls 13A -2ocs: Blk wall, 2 "x4" wood int frm, r -2 ext bd ins, 6" thk, 1/2" n 240 0.201 0 gypsum board int fnsh 6.95 1669 4.06 974 e 440 0.201 0 6.95 3060 4.06 1786 s 209 0.201 0 6.95 1450 4.06 847 w 440 0.201 0 6.95 3060 4.06 1786 all 1329 0.201 0 6.95 9239 4.06 5394 Partitions (none) Windows 1D -c2ow: 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, n 30 0.570 0 19.7 592 20.9 627 1/8" thk e 55 0.570 0 19.7 1085 63.0 3465 s 30 0.570 0 19.7 592 25.2 755 w 55 0.570 0 19.7 1085 63.0 3465 all 170 0.570 0 19.7 3353 48.9 8313 Doors 11D0. Door, wd sc type s 32 0.390 0 13.5 425 11.4 360 Ceilings 16C -19a1: Attic ceiling, asphalt shingles roof mat, r -19 ceil ins, 1/2" 1500 0.049 19.0 1.70 2543 2.10 3146 gypsum board int fnsh Floors 20P -11t: Fir floor, wd flr, 1" thkns, tile fir fnsh, r -11 ext ins, amb ovr 1500 0.078 11.0 2.70 4048 1.00 1498 wrightsoft Right Suite®Universa12012 12.0.04 Right J® Mobile 2012- Apr - 1207:34:51 4CC C: \WINDOWS \T EMP \wstmp\ c4e3 -4b29- 8469- 0323fd0272c4.rup Calc = MJ8 Front Door faces: N Page 1 wrightsoft M Assessment Entire House Date: 4/12/2012 Flint Construction Services By: Russell Flint 1419 Linkside Dr., Atlantic Beach, FL 32233 Phone: 904.994.9626 Fax: 904.372.9011 Email: flintr @comcasst.net Web: www.flintcon.com License: CAC1816283 Project Information For: Laurel Durham 331 10th Street, Atlantic Beach, FL 32233 Phone: 904.864.0889 Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Elevation: 43 ft Indoor temperature ( °F) 70 75 Latitude: 30 °N Design TD ( °F) 35 16 Outdoor: Relative humidity ( %) 30 50 Heating Cooling Moisture difference (gr /Ib) 8.4 Dry bulb ( °F) 35 91 52.8 Infiltration: Daily range ( °F) _ 17 (M) V1\t bulb ( °F) 77 Wind speed (mph) 15.0 7 Test for Adequate Exposure Diversity Hourly Glazing Load 11,00: 10,00: 9,001 8,00e 7,000 6,00: 5,000 4,004 3,000 2,00e 1,00e 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly Aerage FED limit Maximum hourly glazing load exceeds average by 20.8 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh wrightsoft Right -Suite® Universal 2012 12.0.04 Right J® Mobile 2012- Apr - 120734:51 4 (TA C:\ WINDOWS \TEMP\wstmp\22d9cbe1- c4e3 -4b29- 8469- 0323fd0272c4.rup Calc = MJB Front Door faces: N Page 1 :°i CERTI FIE DTM ww w.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3629336 Date: 4/12/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: GSZ130181A* Indoor Unit Model Number: AWUF31XX16A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 17400 EER Rating (Cooling): 11.30* SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 17500 Region IV HSPF Rating (Heating): 8.20* Heating Capacity(Btuh) @ 17 F: 10000 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, ■,.,C1' click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on Air - Conditioning, Heating, which the certificate was issued, which is listed above, and the Certificate No., which is listed below. •� ` and Refrigeration Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129787284018336200