Loading...
Permit Mech 120 Fleet Landing 2012 1 ! .- L` l r ivy CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000411 Date 4/11/12 Property Address 120 FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC RETIREMENT FOUNDATION, INC 6491 POWERS AVENUE 1 FLEET LANDING BLVD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 322334599 (904) 724 -7211 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/08/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: \ V \ee- \airAln `) \t 6 • s 1 X) PERMIT # PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 ` ARI # H U ' I q / 3 Heat: Unit Quantity()1 U KVV( BTU's Per Unit REQUIRED Duct Systems: Total CFM Seer Rating / 3 REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority t jolate the , f visio of any other state or local law regulation construction or the performance of construction. Property Owners Name . , Phone Number Mechanical Company( 6 Gtr \(ra n f A‘0 Office Phone 1) - I I Fax - 1 -5 Co. Address: __\s Q1 . -3 P euc. City "J 6x • State 1' L Zip 3ap-17 License Holder (Print): ,. 4- r / , State - w ification/Registration # Notarized Signature of License Holder t „poi Notary Public State of Florida Sworn and subscribed before me thi lc 20 l V Neal R Major a Of c - s My Commission EE032510 o o � „ Expires 12/20/2014 Signature of Notary Public / f�� + N A19R1 CERTIFIED TM www.ahridirectory.org Certificate of Product Ratin9s 1` AHRI Certified Reference Number: 4261913 Date: 4/11/2012 Product: Split System: Heat Pump with Remote Outdoor Unit- Air - Source Outdoor Unit Model Number: GSZ130361 B* Indoor Unit Model Number: AR *F363616C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 35000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 33600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 20800 " Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. ■ DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. I . The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. oi CERTIFICATE VERIFICATION Ali ��, The information for the model cited on this certificate can be verified at www.ahridirectory.org' Air- Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ■■ *• which the certificate was issued, which is listed above, and the Certificate No., which is listed below. and Refrigeration Institute ©2012 Air- Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129786285338077980 4 wrightsoft°9 Right J® Mobile Report Jab: Entire House Date: 4/9/2012 By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 - 724 -7211 Fax: 904- 724 -5925 Email: operez @davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 120, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) - 17 ( M ) Method Simplified V\,et bulb (°F) - 77 p Cons quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft Btuh % of load Walls 3.4 4385 17.3 Glazing 30.1 5783 22.9 VII Irfiltraim Doors 13.5 425 1.7 Ceilings 2.4 3633 14.4 Floors 4.8 7214 28.5 Ducts Infiltration 2.5 3848 15.2 Qa� 0 0 .ts Fa Piping 0 0 Humidification 0 0 at Ventilation 0 0 Ca lirBs Adjustments 0 Total 25288 100.0 Coolin. Component Btuh/ft Btuh % of load Walls 1.5 1965 8.2 Walls Irtenal C*ins Glazing 61.4 11779 48.9 �Irflitra icn Doors 11.4 360 1.5 Ceilings 3.0 4494 18.7 • Roos Floors 1.8 2669 11.1 Infiltration 0.6 926 3.8 Ducts 0 0 Ventilation 0 0 41 t, Internal gains 1890 7.8 Gaang Ceilings Blower 0 0 Adjustments 0 Cthe Total 24083 100.0 Latent Cooling Load = 2456 Btuh Overall U -value = 0.137 Btuh /ft - °F Data entries checked. VYTIf Ita�'i"? 2012 - Apr -09 14:03:26 Right - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 .4O C: \WINDOWS\ TEMP\ wstmp\ cc6902a6- 7d39- 48c9- bed7- 5192b57b5d30.rup Calc = MJ8 Front Door faces: N A wrightsoft Project Summary Job: Entire House Date: Oniel By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904- 724 -5925 Email: operez @davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 120, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25288 Btuh Structure 24083 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25288 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 24083 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2456 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 1500 1500 Equipment latent load 2456 Btuh Volume (f 13500 13500 Air changes /hour 0.45 0.23 Equipment total load 26539 Btuh Equiv. AVF (cfm) 101 52 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 0 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1096 cfm Actual air flow 1096 cfm Air flow factor 0.043 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A `' wrightsOI Rig ht-Su ite® Universal 2012 12.0.04 Right J® Mobile 2012- Apr- 0914:03:26 ' "— ' C:\WINDOWS\ TEMP\ wstmp\ cc6902a6- 7d39- 48c9- bed7- 5192b57b5d30.rup Calc = MJ8 Front Door faces: N Page 1 4 wrightsoft Right -J® Worksheet Job: Entire House Date: 4/9/2012 David Gray Heating & Air, Inc By Oniel Perez 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904- 724 -5925 Email: operez @davidgrayonline.com 1 Room name 2 Exposed wall Entire House First Floor 3 Room height 170.0 ft 170.0 ft 4 Room dimensions 9.0 ft 9.0 ft heat/cool 5 Room area 1500.0 ft' 1.0 x 1500.0 ft 1500.0 ft' i i i i Ty Construction number (Bt h /ft'e - °F) Or I (Btuh/ft') I or Or (ft) Load 1 Area (ft Load (Btuh) or perimeter (ft) (Btuh) 1 I Heat I Cool I Gross I N /P /S I Heat I Cool 1 Gross I N /P /S Heat I Cool I 6 W 129-Obw 0.097 n 3.36 1.50 270 236 792 355 270 236 792 355 -G 1A -c1ow 0.900 n 31.14 27.95 4 0 130 116 - 0 903 843 30 0 3 G 1D -c2om 0.870 n 30.10 28.08 30 0 0 906 5803 843 . W 12B -Obw 0.097 5 .870 e 0.30 1.50 495 389 585 495 389 0 2 236 585 0 2238 7 11 -G 1D -c2om 0.870 e 30.10 78.45 74 0 2238 5831 74 238 D 1100 0.390 e 13.49 11.43 32 32 425 360 32 32 2425 5831 360 W 12B -Obw 0.097 s 3.36 1.50 270 236 792 355 270 236 792 355 -G 1A -clow 0.900 s 31.14 32.80 4 0 130 137 4 .16 30 0 0 130 137 -G 1 D -c2om 0.870 s 30.10 33.16 903 995 30 0 903 995 V L � 0.097 w 3.36 1.50 495 446 1496 670 495 446 1496 670 1D -c2om 0.870 w 30.10 78.45 49 0 1480 3857 49 0 1480 3857 C 16C -13a1 0.070 - 2.42 3.00 1500 1500 3633 4494 1500 1500 3633 4494 F 20P -5t 0.139 - 4.81 1.78 1500 1500 7214 2669 1500 1500 7214 2669 1 61 c) AED excursion 0 0 Envelope loss /gain 21441 21266 21441 21266 12 a) Infiltration 3848 926 3848 926 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances /other 1200 1200 Subtotal (lines 6 to 13) 25288 24083 25288 24083 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 25288 24083 15 Duct loads 25288 24083 0% 0% 0 0 -0% 0% 0 0 Total o load I 252881 240831 Air requ ed (cfm) I 1096 1096 1 1 2 5096 I 2 40961 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. righ Right - Suite( Universal 2012 12.0.04 Right J® Mobile 2012- Apr- 0914:03:26 C: \ WINDOWS\ TEMP\ wstmp\ cc 7d39- 48c9- bed7- 5192b57b5d30.rup Calc = MJ8 Front Door faces: N Page 1 - I - wrighltsoft Component Constructions Job: Entire House Date: 4/9/2012 By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 - 724 -7211 Fax: 904 - 724 -5925 Email: operez ©davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 120, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 Latitude: 30°N 16 Outdoor: Relative humidity ( %) 30 50 Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) Mt bulb (° F) - 17 (M) Method Simplified 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft. Btuh/ft.-°F ft' - °F /Btuh Btuh /ft' Btuh Btuh/R' Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int n 236 0.097 11.0 3.36 792 1.50 355 fnsh, 2 "x4" wood frm e 389 0.097 11.0 3.36 1306 1.50 585 s 236 0.097 11.0 3.36 792 1.50 355 w 446 0.097 11.0 3.36 1496 1.50 670 all 1307 0.097 11.0 3.36 4385 1.50 1965 Partitions (none) Windows 1A -c1ow: 1 glazing, clr glz, wd frm mat, 1/8" thk n 4 0.900 0 31.1 130 28.0 116 s 4 0.900 0 31.1 130 32.8 137 all 8 0.900 0 31.1 259 30.4 253 1D -c2om: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" n 30 0.870 0 30.1 903 28.1 843 gap, 1/8" thk e 74 0.870 0 30.1 2238 78.4 5831 s 30 0.870 0 30.1 903 33.2 995 w 49 0.870 0 30.1 1480 78.4 3857 all 184 0.870 0 30:1 5524 62.8 11526 Doors 11 D0: Door, wd sc type e 32 0.390 0 13.5 425 11.4 360 Ceilings 16C -13a1: Attic ceiling, asphalt shingles roof mat, r -13 ceil ins, 1/2" 1500 0.070 13.0 2.42 3633 3.00 4494 gypsum board int fnsh Floors 20P -5t: Fir floor, wd flr, 1" thkns, tile flr fnsh, r -5 ext ins, amb ovr 1500 0.139 5.0 4.81 7214 1.78 2669 ': wrigh of Right - Suite® Universal 2012 12.0.04 Right J® Mobile 2012-Apr-09 ' AC C: \WINDOWS\ TEMP\ wstmp\ cc6902a6- 7d39- 48c9- bed7- 5192b57b5d30.rup Calc = MJ8 Front Door faces: N Page ACC/1/4 1 wrightsoft. AED Assessment Job: Entire House Date: Oniel By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904-724 -5925 Email: operez(B3davidgrayonline.com Project Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 120, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Elevation: 43 ft Indoor temperature ( °F) 70 75 Latitude: 30 °N Design TD ( °F) 35 16 Outdoor: Relative humidity ( %) 30 50 Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Vet bulb ( °F) 77 Wind speed (mph) 15.0 7 Test for Adequate Exposure Diversity Hourly Glazing Load 16,00: 14,00: 12,00 4 10,001 ... „,m,. 8,00: 6,00: 4,00: 2,00: 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Hourly Aerage PEDlinit Maximum hourly glazing Toad exceeds average by 13.0 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh I� * wrightsoft Right - Suite® Universal 2012 12.0.04 Right J® Mobile 2012 -Apr- 0914:03:26 C: \WINDOWS\ TEMP\ wstmp\ cc6902a6- 7d39- 48c9- bed7- 5192b57b5d30.rup Calc = MJ8 Front Door faces: N Page 1