Loading...
Permit Mech 1671 Francis Ave (jordan Park) 2012 1 , 0.14 � jrjr,' : Y '' ` z CITY OF ATLANTIC BEACH ## j 800 SEMINOLE ROAD op , J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000486 Date 4/26/12 Property Address 1671 FRANCIS AVE Tenant nbr, name JORDAN PARK Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 7320 Application desc Change out 3 - 4 ton systems Owner Contractor CITY OF ATLANTIC BEACH B & G REFRIGERATION 800 SEMINOLE RD 3230 KLINE RD. ATLANTIC BEACH FL 322335428 JACKSONVILLE FL 32246 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 3 - 4 TON SYSTEMS Permit Fee . . . 211.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/23/12 Fee summary Charged Paid Credited Due Permit Fee Total 211.00 211.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 211.00 211.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. : , � CITY OF ATLANTIC BE.AI s� 800 SEMINOLE ROAD j ; ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Ofl Application Number 12- 00000486 Date 4/26/12 Property Address 1671 FRANCIS AVE Tenant nbr, name JORDAN PARK Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 7320 Application desc Change out 3 - 4 ton systems Owner Contractor CITY OF ATLANTIC BEACH B & G REFRIGERATION 800 SEMINOLE RD 3230 KLINE RD. ATLANTIC BEACH FL 322335428 JACKSONVILLE FL 32246 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 3 - 4 TON SYSTEMS Permit Fee . . . 211.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/23/12 Other Fees STATE MECH DCA SURCHARGE 3.17 STATE MECH DBPR SURCHARGE 3.17 Fee summary Charged Paid Credited Due Permit Fee Total 211.00 211.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 6.34 6.34 .00 .00 Grand Total 217.34 217.34 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS:1063 -0 A �.c k \UC 1 � CA. (V11 S l A ue_ PERMIT # 1 L -- 6 So PROJECT VALUE $ - I ' a0 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION 105 ARI # yL N /I-kg 3V'3a� Air Conditioning: Unit Quantity o) / 1 Tons Per Unit 3 I Lk - 6ns REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating 1 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells DTHER: 'emit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified )r not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of constriction. 'roperty Owners Name D U► R OG11V1 : �Q.C( Phone Number q i N1 • C an Y--C --I _ r ` vlechanical Company (� p Y � �- YCl gl�����6� lJ� 1 1 \ Office PhonegDala MIFaxQb-) iPX)• :o. Address: 393D line 1 A City i £U State PI Zip ,'GN--klD License Holder (Print): 10 r1 1. / r ...f State Certification/Registration # CRC RI ? 103 Votarized Signature of License Holder' , , 1 1 orn and subscribed before me 's day of f / 20/4 ,f0.0. KY p `e`ni STEPHANES STRAHAN / / � , ` ? 1 Notary Public - State of florid' _nature of Notary Public / �' _..% �`.? I g My Comm. Expires Apr 12, 2015 ',, ;;, «c ' Commission +y EE 72055 7LATIONS IJ J 4.3 0 - 101(1 Phone 2 i N PC- 3 ( 1 L & Zip FL Phone (904) 268 -3670 __.._,. -. �� • llJ4 & Zip FL, 32223 1 ° O ) 1 9 ] 1 (-- l.1201' k _.__ -__.7 i•M Dly Range 19 rains 49 - inside db 72 tor= M COOLING LOAD Exposure Shading / NOTES Sq. Ft. SolrFactr GlasFactr Sensible N 12 X 19 X 0.7 = 160 NE X 38 X 0.7 = E X 56 X 0.7 = SE X 57 X 0.7 = S 48 X 48 X 0.7 = 1613 SW X 88 X 0.7 = W 84 X 81 X 0.7 = 4763 NW X 39 X 0.7 = 3. TRANSMISSION GAINS Equiv or Exposure db Sq. Ft. U Factor Temp Diff Glass 144 X 0.8 X 22 = 2534 N 450 X 0.09 X 22 = 891 NE X 0.09 X 26 = E 950 X 0.09 X 31 = 2651 Walls SE X 0.09 X 33 = S 450 X 0.09 X 41 = 1661 SW X 0.09 X 47 = W 950 X 0.09 X 43 = 3677 NW X 0.09 X 28 = Doors 63 X 0.58 X 18 = 652 Partition X 0.05 X 22 = RA Cing X 0.09 X 22 = Roof/Clng 3775 X 0.05 X 57 = 10759 Floors 280 X X 22 = X X = Use Table 9a to Determine the Temp. Dif. Across an RA Ceiling PAGE TWO 4. INTERNAL HEAT GAIN Latent a. OCCUPANTS Number Sensible Latent 40 X 230 = 9200 X = 40 X 170 = 6800 X = b. Lights & Others NOTE:Use 60% of installed watts for lights in RETURN AIR CEILING Watts Incandescnt X 3.4 = Flourescent 4000 X 4.1 = 16400 HP Motors Btuh Usg Ftr X = X = Appliances Other 5. INFILTRATION Ft3 /Min db Temp Dif 110 X 22 X 1.1 = 2662 Grains Diff 110 X 49 X 0.68 = 3665 6. SUBTOTALS LOADS & SPACE LOADS 57621 10465 7. DUCT HEAT GAIN Gain Line 6 Factor Sensible 0.1 X 57621 = 8. ROOM, SPACE OR DESIGN LOAD Add Duct gain (7) to Subtotal (6) 57621 9. VENTILATION Ft3 /Min db Temp Dif 800 X 22 X 1.1 = 19360 Grains Diff 800 X 49 X 0.68 = 26656 PAGE THREE 10. RETURN AIR LOAD FROM LIGHTING AND ROOF NOTE: Use 40% of watts for lights recessed in a return air ceiling Incandescent X 3.4 = Flourescent X 4.1 = NOTE: Use 100% fo the roof load for return air ceilings (Roof Load) Sq. Ft. U Factor ETD* X 0.09X = *(ETD correction based on plenum temp.) 11. TOTAL SENSIBLE LOAD ON EQUIPMENT (Btuh) = 76981 TOTAL LATENT LOAD ON EQUIPMENT (Btuh) 37121 12. TOTAL COOLING LOAD ON EQUIPMENT (Btuh) 1 114102 (Tons) 9.51 PAGE FOUR HEATING LOAD 13. DESIGN LOADS Inside db Outside db b Difference 72 - 32 = 40 14. TRANSMISSION LOSSES HEATING LOAD db Exp. Sq. Ft. Factor Temp Diff Heating Load Windows 594 x 1.13 x 40 = 26849 x x = 950 x 0.09 x 40 = 3420 Walls 450 x 0.09 x 40 = 1620 x 0.09 x = 950 x 0.09 x 40 = 3420 x 0.09 x = Roof/ 3775 x 0.05 x 40 = 7550 Ceiling x 0.05 x = x x = Floor 280 x 0.81 x 40 = 9072 Other x x = x x = 15. INFILTRATION db Ft3 /Min Temp Diff 165 X 40 X 1.1 = 7260 16. SUBTOTAL HEATING LOAD FOR SPACE 59191 17. DUCT HEATING LOSS Loss Line 14 Factor Subtotal 0.15 X 51931 = 7790 18. VENTILATION db Ft3 /Min Temp Diff 800 X 40 X 1.1 = 35200 19. HUMIDIFICATION LOAD Inside RH Desired ( ) Max ( ) Ft3 /Min Btu /Hr / 100 X = (water) (air) gal /day Ft3 /Min X / 100 = 20. TOTAL HEATING LOAD ON EQUIPMENT (Btuh) I 102180 (Tons) 8.52 Energy Design Systems, Inc. 12132 Weatherwood Estates Dr. W. Jacksonville, FL 32223 (904) 268 -3670