Loading...
Permit Mech 145 Pine St 2012 r JJy :J� F? CITY OF ATLANTIC BEACH 1 s) 800 SEMINOLE RO J - ...4 Z.1 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 013 Application Number 12- 00000481 Date 4/26/12 Property Address 145 PINE ST Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor WELLS JOHN BENJAMIN JR ET AL SERVICE EXPERTS WELLS CAROL EVANS R/S 8475 WESTERN WAY STE 100 145 PINE ST JACKSONVILLE FL 32256 ATLANTIC BEACH FL 32233 (904) 641 -2333 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 95.00 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/23/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 95.00 95.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 99.00 99.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. %i q 9 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / q 5 y /�/ /t/ e s • -/ __ . PERMIT # PROJECT VALUE $ C---- c2 o NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Duct Systems: Total CFM Seer Rating REQUIRED REPLACEMENT MR CONDITIONING & HEATING SYSTEM INSTALT„ 4 Jig" Air Conditioning: Unit Quantity ARI # � 7 /3 Q Tons Per Unit (2 5 QV/ D Heat: Unit Quantity i BTU's Per Unit ,3 P, pen) Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 2 O k iJ We /7 -C Phone Number ' 1/43 6 — 9 `J Mechanical Company • ►f - 4`° C t' Pit L fe Office Phone 1,91-avl',Fax Co. Address: 61-175 wt-S4-en, (A, aU I (co Ci ' tyJGC�' StateF Zip �jc.) • License Holder (Print): dx-Eky j ZA'/ State Certification/Registration At a1 /8/35- Notarized Signature of License Holder 61,7,7 . : Sworn and s> re before me this day of 20 / �� -, CARO Notary P ublic v a L I MYc E s teof d C 201 mmiss# 5 4 FE 36112 Customer Information Location: Street Address 145 pine st, DUVAL, FL 32233 Latitude, Longitude 30.3375 °, - 81.7686° House Square Footage: 1202 sq. ft Name: John Wells Phone: 913 - 636 -9891 Email: Wayne.furr @service experts.com Desi• n Conditions Outdoor Heating Cooling Dry bulb ( °F) 32 95 Daily range M Relative humidity 50% Moisture difference 53 Indoor Heating Cooling Indoor temperature ( °F) 70 75 Design temperature difference( °F) 38 20 Heatin' Loads Area Btuh % of load Wall 2649 11.4 Floor 5753 24.8 Ceiling 2284 9.8 Windows 4788 20.6 Infiltration 5607 24.2 System Efficiency Loss 2108 9.1 Total: 23189 . .................... Heating Loads 23,189 BTU /hr System Efficiency Loss Floor Ceiling Wall Infiltration -// Windows Coolin' Loads Area Btuh % of load Wall 1394 5.5 Ceiling 1202 4.8 Windows 12204 48.5 Sensible Infiltration 2213 8.8 Latent Infiltration 3626 14.4 System Efficiency Gain 2064 8.2 Internal 1349 5.4 Sensible People Load 553 2.2 Latent People Load 553 2.2 Total: 25158 Sensible load 20979 Latent load 4179 SHR 0.83 Capacity at .75 SHR 2.33 Tons Cooling Loads 25,158 BTU /hr F . Sensible People Load Latent People Load I Ceiling Tr Internal rio.,'''-' Wall Windows System Efficienci '''''.""-- Sensible Infiltration `- Latent Infiltration Ade. uate Ex. osure Diversi AED Graph 20000 _ .. - __° -_ __ — 15000 i 0 10000 J 5000 Sam gam loam clam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm — Hourly Loads — Average , ACCA Manual S System equipment selection will be made using the fdlawing Manual S derived values. Summer Outdoor 95 °F Summer Wet Bulb 77 °F Summer Indoor 75 °F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70 °F Sensible Coding 20,979 Btuh Latent Coding 4,179 Btuh Required Coding Airflow 954 CFM Sensible Heating 23,189 Btuh Required Heaing Airflow 301 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree rul ell CERTIFIED TM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4637123 Date: 4/26/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 14HPX- 030 - 230 -13 Indoor Unit Model Number: CH23- 51 +TDR +TXV Furnace Model Number: G61 MPV -36B -070" Manufacturer: LENNOX INDUSTRIES, INC. Trade /Brand name: 14HPX SERIES Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 27200 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 26600 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 16400 * Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air- Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on � Illk' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129799201725784594 i