Loading...
Permit Mech 5603 Fleet Landing 2012 ?S 1.„1.rt j:1. ' l' 1r' . CITY OF ATLANTIC BEACH J ; <; X1 jj�� J 800 SEMINOLE ROAD K ATL A w NTIC BEACH, FL 32233 `� ' ` INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000482 Date 4/25/12 Property Address 1 FLEET LANDING BLVD MAIN Tenant nbr, name 5603 FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 3500 Application desc CHANGE OUT 3 TON SYSTEM Owner Contractor NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724 -7211 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 3 TON SYSTEM Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/22/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 i( J i 1 } PERMIT # J� " JOB ADDRESS: f IQ, 7 l-i �� \ 1 A-4- 1 Cc ?` C -P 6.(.. Y1 i (-- P 3'Z Zia Dri I ° PROJECT VALUE $ 5 ,5 - 1 90 o ° , e° NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION, " S Air Conditioning: Unit Quantity L Tons Per Unit '3 REQUIRED Heat: Unit Quantity Z- BTU's Per Unit -3'3) fv 0 Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: � U II # ° 3 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name lee 1 - C,4 H O l n Phone Number ' = " `� 900 Mechanical Company C ,,, i' Gay l'f c b by 4 ✓ Office Phone q-Z 9 --WI Fax 1 2--f — 5-9 2 - • Co. Address: (yV. Pa -le(I A vi &I" City ) o�c,k' f )l State ; CC. Zip 3 2z 1'7-- License �iuypt): 1/t J 1.:i cke rtification/Registration # C. f K 05 tE (: ` " ' • •. •' Sense i c Notat*ense Holder L�` a nY t^ •Expires = Sworn and subscribed before me this $ da of v % f 20 1 2. • ry1 ,2 p14 • C = o oo 13 ' - Signature of Notary Public ) )�.� J Job: 4 Right J® Mobile Report Date: 4/25/2012 uvrightsoft ' Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904- 724 -5925 Email. operez @davidgrayonline.com Pro - ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5603, Atlantic Beach, FL 32233 Phone: 904 - 246 -9900 Email: operez @davidgrayonline.com Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Design TD ( °F) 35 16 L Latitude: 30 °N 43 ft Relative humidity ( %) 30 50 Outdoor: Heating Cooling Luddee: Moisture difference (gr /Ib) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 ( M ) Method Simplified Wet bulb ( °F) 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft Btuh % of load Walls 3.4 3955 13.6 VAI Irfiltr iai Glazing 43.9 6152 21.1 Doors 12.1 381 1.3 Ceilings 3.9 4844 16.6 Floors 8.5 10639 36.5 aaA Infiltration 2.4 3206 11.0 Ducts 0 0 , Ram Piping 0 0 C1ts Humidification 0 0 Calirys Ventilation 0 0 Adjustments 0 Total 29178 100.0 • Coolin • Component Btuh/ft Btuh % of load Walls 1.5 1772 7.5 VElls herd Cars Glazing 61.8 8659 36.7 Irfiltratirn Doors 10.3 323 1.4 Ceilings 4.8 5992 25.4 Floors 3.1 3936 16.7 ,Flocs Infiltration 0.6 772 3.3 Qa rrj- Ducts 0 0 Ventilation 0 0 Internal gains 2120 9.0 Blower 0 0 Adjustments 23574 0 100.0 a Ceilings Total Latent Cooling Load = 2347 Btuh Overall U -value = 0.195 Btuh /ft - °F Data entries checked. 2012- Apr -25 07:37:15 ,,,,,_ wrightsoft Right - Suite® Universal 2012 12.0.04 Right JO Mobile Page 1 ._ C, . C: \WINDOWS\ TEMP \wstmp \42a93d35 -6d4b- 4684- a8b9- 31596bb72bec.rup CaIc = MJ8 Front Door faces: N Job: 4 Wrightsoft Project Summary Date: o�se2012 Entire House David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez@davidgrayonline.com Project Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5603, Atlantic Beach, FL 32233 Phone: 904 - 246 -9900 Email: operez @davidgrayonline.com Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 29178 Btuh Structure 23574 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29178 Btuh Use manufacturer's data Y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 23574 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Structure 2347 Btuh Fireplaces Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 1250 1250 Equipment latent load 2347 Btuh Volume (ft 11250 11250 Air changes /hour 0.45 0.23 Equipment total load 25920 Btuh Equiv. AVF (cfm) 84 43 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1073 cfm Actual air flow 1073 cfm Air flow factor 0.037 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012- Apr -25 07:37:15 Wriglhtsaft Right- Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 ./C C: \VNNDOWS\ TEMP\ wstmp\ 42a93d35 -6d4b- 4684- a6b9- 31596bb72bec.rup Calc = MJ8 Front Door faces: N R i ht -J® Worksheet Job: p} W rj[�flt5oft g Date: 4/25/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 - 724 -7211 Fax: 904 - 724 -5925 Email: operez@davidgrayonline.com Entire House First Floor 1 Room name 150.0 ft 150.0 ft 2 R wall 9.0 ft 9.0 ft heat/cool 3 R000m om h eight 25.0 x 50.0 ft 4 Room dimensions 1250.0 ft' 1250.0 ft' 5 Room area 1 i 1 Load Ty Construction U -value Or I HTM Area (f t') Load I Area (ft') number (Btuh /ft' - °F) (Btuh /ft') I or perimeter (ft) I (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N /P /S Heat I Cool I Gross N /P /S Heat Cool 6 Vt1 12B -Obw 0.097 n 3.36 1.50 450 405 1359 609 450 405 1359 609 L--G 1A -clom 1.270 n 43.94 36.26 45 0 1977 1632 45 0 1977 1632 . W 128-Obw 0.097 e 3.36 1.50 225 154 515 231 225 154 515 231 1A -clom 1.270 e 43.94 92.64 40 0 1758 3706 40 0 1758 3706 1 1 D 11 NO 0.350 e 12.11 10.26 32 32 381 323 32 32 381 323 Vt/ 12B -Obw 0.097 s 3.36 1.50 450 415 1393 624 450 415 1393 624 G, 1A -clom 1.270 s 43.94 41.95 35 0 1538 1468 35 0 1538 1468 W 12B -Obw 0.097 w 3.36 1.50 225 205 688 308 225 205 688 308 L-G 1A -clom 1.270 w 43.94 92.64 20 0 879 1853 20 0 879 1853 C 16C -7a1 0.112 - 3.88 4.79 1250 1250 4844 5992 1250 1250 4844 5992 F 20P -2t 0.246 - 8.51 3.15 1250 1250 10639 3936 1250 1250 10639 3936 6 c) AED excursion 0 0 Envelope loss /gain 25972 20682 f 25972 20682 12 a) Infiltration 3206 772 320 77 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances /other 1200 1200 Subtotal (lines 6 to 13) 29178 23574 29178 23574 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 0 Redistribution 29178 23574 29178 23574 14 Subtotal 15 Duct loads 0% 0% 0 0 -0% % 0% 0 0 I Air Total requi room red load (cfm) I I I 29178 1073 I 235741073 1 I J I 29178 1073 I 23574 1073 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012- Apr -25 07:37:15 wr;ghtsi)ft Right - Suite® Universal 2012 12.0.04 Right J® Mo bile Page 1 ` '�" '" C. \WINDOWS\ TEMP \wstmp \42a93d35 -6d4b- 4684- a8b9- 31596bb72bearup Calc = MJ8 Front Door faces: N wCightsoft Component Constructions Job: "Pk Date: 4/25/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez©davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5603, Atlantic Beach, FL 32233 Phone: 904 - 246 -9900 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Design TD ( °F) 35 16 Latitudde: : e 30 °N Elevation: 43 ft Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Simplified Daily range ( °F) - 17 (M ) Method P Wet bulb (°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain ft' Btuh /ft` - °F ft' - °F /Btuh Btuh /ft. Btuh Btuh/ft. Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int n 405 0.097 11.0 3.36 1359 1.50 609 fnsh, 2 "x4" wood frm e 154 0.097 11.0 3.36 515 1.50 231 s 415 0.097 11.0 3.36 1393 1.50 624 w 205 0.097 11.0 3.36 688 1.50 308 all 1179 0.097 11.0 3.36 3955 1.50 1772 Partitions (none) Windows 1A -clom: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk n 45 1.270 0 43.9 1977 36.3 1632 e 40 1.270 0 43.9 1758 92.6 3706 s 35 1.270 0 43.9 1538 41.9 1468 w 20 1.270 0 43.9 879 92.6 1853 all 140 1.270 0 43.9 6152 61.8 8659 Doors 11 NO: Door, mtl eps core type e 32 0.350 8.7 12.1 381 10.3 323 Ceilings 16C -7a1: Attic ceiling, asphalt shingles roof mat, r -7 ceil ins, 1/2" 1250 0.112 7.0 3.88 4844 4.79 5992 gypsum board int fnsh Floors 20P -2t: FIr floor, wd flr, 1" thkns, tile flr fnsh, r -2 ext ins, amb ovr 1250 0.246 2.0 8.51 10639 3.15 3936 2012- Apr -25 07:37:15 .. wrigllltsoft Right - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 ACCT C: \WINDOWS\ TEMP \wstmp \42a93d35 -6d4b- 4684- a8b9- 31596bb72bec.rup Calc = MJ8 Front Door faces: N Job: wrightsoft AED Assessment Date: 4/25/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904- 724 -5925 Email: operez @davidgrayonline.com Project Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5603, Atlantic Beach, FL 32233 Phone: 904 - 246 -9900 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Indoor temperature ( °F) 70 75 Eleva onn:lle /Craig, FL, US Design TD ( °F) 35 16 Lattititudude: : 43 30 °N ft Elevation: ft Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (g r /Ib ) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) VW bulb ( °F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 12,000 - 11,000- 10,000— 8,000 - 7,000- 6,000- 5,000- 4,000- 3,000- 2,000- 1,000- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Homy Ael , PEDlirrit Maximum hourly glazing Toad exceeds average by 13.6 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012- Apr -25 07:37:15 wrights0ft" Ri - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 ACC1, C: \WINDOWS\ TEMP\ wstmp\ 42a93d35 -6d4b- 4684- a8b9- 31596bb72bec.rup Calc = MJ8 Front Door faces: N